1
|
Maino C, Mariani I, Drago SG, Franco PN, Giandola TP, Donati F, Boraschi P, Ippolito D. Computed Tomography and Magnetic Resonance Enterography: From Protocols to Diagnosis. Diagnostics (Basel) 2024; 14:2584. [PMID: 39594251 PMCID: PMC11592478 DOI: 10.3390/diagnostics14222584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2024] [Revised: 11/14/2024] [Accepted: 11/15/2024] [Indexed: 11/28/2024] Open
Abstract
Both Magnetic Resonance Enterography (MRE) and Computed Tomography Enterography (CTE) are crucial imaging modalities in the diagnosis and treatment of inflammatory bowel disease (IBD). CTE is often used in acute scenarios, such as when complications (such as abscesses, perforations, or bowel obstructions) are suspected. It can also help determine the degree and extent of pathological processes. Although CTE is rapid, generally accessible, and offers precise images that are useful in emergencies, it does expose patients to ionizing radiation. Nevertheless, MRE is very useful in assessing perianal illness and the small intestine, and it is frequently used in patients who need repeated follow-ups or are pregnant to minimize radiation exposure. Moreover, MRE can demonstrate oedema, fistulas, abscesses, and the thickening of the bowel wall. In addition, MRE offers superior soft tissue contrast resolution without ionizing radiation, which helps identify complications such as fistulas and abscesses. With their respective advantages and disadvantages, both approaches play essential roles in assessing IBD. The primary goal of this review is to provide an overview of the technical specifications, benefits, drawbacks, and imaging findings of CTE and MRE.
Collapse
Affiliation(s)
- Cesare Maino
- Department of Diagnostic Radiology, IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (I.M.); (S.G.D.); (P.N.F.); (T.P.G.); (D.I.)
| | - Ilaria Mariani
- Department of Diagnostic Radiology, IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (I.M.); (S.G.D.); (P.N.F.); (T.P.G.); (D.I.)
| | - Silvia Girolama Drago
- Department of Diagnostic Radiology, IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (I.M.); (S.G.D.); (P.N.F.); (T.P.G.); (D.I.)
| | - Paolo Niccolò Franco
- Department of Diagnostic Radiology, IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (I.M.); (S.G.D.); (P.N.F.); (T.P.G.); (D.I.)
| | - Teresa Paola Giandola
- Department of Diagnostic Radiology, IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (I.M.); (S.G.D.); (P.N.F.); (T.P.G.); (D.I.)
| | - Francescamaria Donati
- 2nd Unit of Radiology, Department of Radiological Nuclear and Laboratory Medicine, Pisa University Hospital, Via Paradisa 2, 56124 Pisa, Italy; (F.D.); (P.B.)
| | - Piero Boraschi
- 2nd Unit of Radiology, Department of Radiological Nuclear and Laboratory Medicine, Pisa University Hospital, Via Paradisa 2, 56124 Pisa, Italy; (F.D.); (P.B.)
| | - Davide Ippolito
- Department of Diagnostic Radiology, IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (I.M.); (S.G.D.); (P.N.F.); (T.P.G.); (D.I.)
- School of Medicine, University of Milano Bicocca, Via Cadore 33, 20090 Monza, Italy
| |
Collapse
|
2
|
Kim J, Dane B. Evidence-Based Review of Current Cross-Sectional Imaging of Inflammatory Bowel Disease. Radiol Clin North Am 2024; 62:1025-1034. [PMID: 39393848 DOI: 10.1016/j.rcl.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2024]
Abstract
CT and MR enterography are cross-sectional imaging examinations used in the assessment of inflammatory bowel disease. Consistent reporting and standardized nomenclature are important for clear communication with referring clinicians. Enterography has not only been used to depict inflammation in the small bowel, but it has also been used to quantify disease activity, assess distribution of disease, and detect complications including penetrating disease. This article reviews cross-sectional imaging findings in inflammatory bowel disease, including the current literature focusing on small bowel Crohn's disease and ulcerative colitis, with evidence-based guidelines on appropriate protocols and imaging procedures.
Collapse
Affiliation(s)
- Jesi Kim
- Department of Radiology, NYU Langone Health, New York, NY 10016, USA; Diagnostic Radiology, NYU Grossman School of Medicine, 660 1st Avenue, New York, NY 10016, USA; Department of Radiology, NYU Langone Health, 660 1st Avenue, New York, NY 10016, USA
| | - Bari Dane
- Department of Radiology, NYU Langone Health, 660 1st Avenue, New York, NY 10016, USA.
| |
Collapse
|
3
|
Siow JW, Chau J, Podadera JM, Makara M. Investigation of scan delays for CT evaluation of inner wall layering and peak enhancement of the canine stomach and small intestine using a 20 second fixed-injection-duration and bolus tracking technique. Vet Radiol Ultrasound 2023; 64:42-52. [PMID: 35959974 PMCID: PMC10087455 DOI: 10.1111/vru.13142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 05/27/2022] [Accepted: 05/30/2022] [Indexed: 01/25/2023] Open
Abstract
Many gastrointestinal diseases affect the mucosal layer, suggesting that on computed tomography (CT) examination, detection of consistent inner wall layering of the gastrointestinal tract may aid in detection of disease. Changes in wall enhancement can also characterise specific diseases and provide prognostic information. The objectives of this mixed retrospective and prospective analytical study were therefore to identify the scan delays for peak detection of canine stomach and small intestinal inner wall layering and enhancement when using a 20 s fixed-injection-duration and bolus tracking technique. For each patient, 700 mg I/kg iohexol was administered intravenously. Bolus tracking was used to determine aortic arrival. Diagnostic scans were performed after a post-aortic arrival scan delay. Postcontrast CT series were grouped according to post-aortic arrival scan delay: 5 s (n = 17), 10 s (n = 18), 15 s (n = 23), 20 s (n = 10), 25 s (n = 6), 30 s (n = 14), 35 s (n = 17), 40 s (n = 24), and 180 s (n = 60). The stomach and small intestine were assessed for the presence of a contrast-enhancing inner wall layer and wall enhancement. Statistical modeling showed that the scan delays for peak inner wall layering and enhancement were 10 and 15 s for the small intestine, respectively, and 40 s for the stomach. For the injection protocol used in this study, assessment of the canine gastrointestinal tract may use scan delays of 10-15 s and 40 s.
Collapse
Affiliation(s)
- Jia Wen Siow
- University Veterinary Teaching Hospital, School of Veterinary Science, University of Sydney, Camperdown, New South Wales, Australia
| | - Jennifer Chau
- University Veterinary Teaching Hospital, School of Veterinary Science, University of Sydney, Camperdown, New South Wales, Australia
| | - Juan M Podadera
- University Veterinary Teaching Hospital, School of Veterinary Science, University of Sydney, Camperdown, New South Wales, Australia
| | - Mariano Makara
- Northside Veterinary Specialists, 335 Mona Vale Road, Terrey Hills, New South Wales, Australia
| |
Collapse
|
4
|
Fujimura H, Hashimoto S, Shimizu K, Onoda H, Tanabe M, Higashi M, Ogawa R, Goto A, Hamabe K, Nishikawa J, Ito K, Takami T. The Evaluation of Transmural Healing by Low-dose Computed Tomography Enterography in Patients with Crohn's Disease. Intern Med 2022; 61:2999-3007. [PMID: 36244733 PMCID: PMC9646332 DOI: 10.2169/internalmedicine.9066-21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 12/26/2021] [Indexed: 11/11/2022] Open
Abstract
Objective Transmural healing (TH) has been attracting attention as a new therapeutic target for Crohn's disease, but there are few clinical data on TH in Japan. We introduced low-dose computed tomography enterography (CTE) as a monitoring method for Crohn's disease and retrospectively investigated the accuracy of evaluating TH by CTE. Methods Among Crohn's disease patients who underwent low-dose CTE at our hospital from January 2009 to March 2021, 122 patients who underwent colonoscopy or balloon endoscopy within 2 weeks were included. Results of radiological and endoscopic examinations were reviewed independently by radiologists and gastrointestinal endoscopists, respectively. The concordance rate of the diagnosis between CTE and endoscopy was evaluated. Results Twenty-six patients (21.3%) achieved TH, and the kappa index was 0.743. On comparing the TH and non-TH groups, the Crohn's disease activity index (p=0.02), endoscopic healing rate (p<0.001), serum albumin (p=0.043), and serum C-reactive protein level (p=0.018) showed significant differences. Among the 122 patients, 69 (56.5%) showed concordance between the diagnosis of CTE and endoscopy, and 22 (18.0%) achieved both TH and endoscopic healing. Conclusion This study provides real-world data on Crohn's disease evaluated with low-dose CTE in Japan. The TH criterion used in this study has a high kappa coefficient and can be used reproducibly in many institutions.
Collapse
Affiliation(s)
- Hiroyuki Fujimura
- Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, Japan
| | - Shinichi Hashimoto
- Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, Japan
| | | | - Hideko Onoda
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Japan
| | - Masahiro Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Japan
| | - Mayumi Higashi
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Japan
| | - Ryo Ogawa
- Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, Japan
| | - Atsushi Goto
- Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, Japan
| | - Koichi Hamabe
- Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, Japan
| | - Jun Nishikawa
- Faculty of Laboratory Science, Yamaguchi University Graduate School of Medicine, Japan
| | - Katsuyoshi Ito
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Japan
| | - Taro Takami
- Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, Japan
| |
Collapse
|
5
|
Shinya T. Malignant Small Bowel Neoplasms:a review of post-contrast multiphasic multidetector computed tomography. THE JOURNAL OF MEDICAL INVESTIGATION 2022; 69:19-24. [PMID: 35466141 DOI: 10.2152/jmi.69.19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Small bowel neoplasms are rare and account for 3-6% of all gastrointestinal neoplasms. For the diagnosis of small bowel neoplasms, differentiating normal bowel tissue from tumor is critical and depends on imaging modality and scanning techniques. The detection and characterization of small bowel neoplasms have recently improved with the advance of computed tomography (CT) technology. Post-contrast multiphasic CT is an aid to detection and recognition of the vascular nature of small bowel neoplasms. Understanding the typical post-contrast multiphasic CT features of small bowel neoplasms is important because of overlapping features and the necessity of evaluating associated complications and metastases to lymph node and other organs. However, accurate classification of pathologies is still challenging in clinical practice. Texture analysis can quantify complex mathematical patterns within the gray-level distribution of the pixels and voxels of digital images, and texture analysis of the post-contrast multidetector CT data of various tumors has been attracting attention in recent years. The aim of this article is to provide a comprehensive guide to the relevant imaging features for different types of malignant small bowel neoplasms. J. Med. Invest. 69 : 19-24, February, 2022.
Collapse
Affiliation(s)
- Takayoshi Shinya
- Department of Community Medicine and Medical Science, Tokushima University Graduate School of Biomedical Sciences. 3-18-15, Kuramoto-cho, Tokushima City, Tokushima, 770-8503, Japan
| |
Collapse
|
6
|
Guglielmo FF, Anupindi SA, Fletcher JG, Al-Hawary MM, Dillman JR, Grand DJ, Bruining DH, Chatterji M, Darge K, Fidler JL, Gandhi NS, Gee MS, Grajo JR, Huang C, Jaffe TA, Park SH, Rimola J, Soto JA, Taouli B, Taylor SA, Baker ME. Small Bowel Crohn Disease at CT and MR Enterography: Imaging Atlas and Glossary of Terms. Radiographics 2020; 40:354-375. [DOI: 10.1148/rg.2020190091] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
7
|
Mang T, Scharitzer M. [Imaging of gastrointestinal inflammation : Characteristic patterns and signs]. Radiologe 2019; 58:281-291. [PMID: 29572712 DOI: 10.1007/s00117-018-0376-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
CLINICAL PROBLEM Pathological conditions of the gastrointestinal tract can result from various disorders, including inflammatory, infectious, neoplastic, and ischemic diseases. RADIOLOGICAL STANDARD PROCEDURES Cross-sectional imaging techniques have largely replaced many of the conventional fluoroscopic examinations, such as small bowel follow-through and double-contrast barium enema. The former allow for time-efficient, accurate, and minimally invasive diagnostics. Therefore, they have become important diagnostic tools for the evaluation of inflammatory diseases of the gastrointestinal tract. The distension of the intestinal lumen with orally administered neutral contrast media improves not only the evaluation of the intraluminal aspect, but also of the cross-sectional appearance. Furthermore, with cross-sectional imaging techniques, the additional assessment of the extraintestinal structures and organs is also possible. METHODICAL INNOVATIONS AND ASSESSMENT With the ongoing development of scanner and software technology, pathologic conditions of the gastrointestinal wall can be characterized in more detail by both computed tomography and magnetic resonance imaging. A structured approach, based on the analysis of typical radiological signs and patterns, combined with the evaluation of extraintestinal findings may help to assign the observed imaging findings to specific disease groups. RECOMMENDATIONS This article summarizes common signs and typical patterns frequently seen in inflammatory conditions of the gastrointestinal tract. A systematic approach for structured analysis of specific and nonspecific imaging features and common pitfalls may aid in the interpretation and help to narrow the spectrum of potential differential diagnoses.
Collapse
Affiliation(s)
- T Mang
- Universitätsklinik für Radiologie und Nuklearmedizin, Medizinische Universität Wien, Währinger Gürtel 18-20, 1090, Wien, Österreich.
| | - M Scharitzer
- Universitätsklinik für Radiologie und Nuklearmedizin, Medizinische Universität Wien, Währinger Gürtel 18-20, 1090, Wien, Österreich
| |
Collapse
|
8
|
Varyani F, Samuel S. "Can Magnetic Resonance Enterography (MRE) replace ileo-colonoscopy for evaluating disease activity in Crohn's disease?". Best Pract Res Clin Gastroenterol 2019; 38-39:101621. [PMID: 31327407 DOI: 10.1016/j.bpg.2019.05.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 05/23/2019] [Indexed: 01/31/2023]
Abstract
Crohn's disease is a form of chronic inflammatory bowel disease that can lead to structural bowel damage due to transmural inflammation. Ileo-colonosocopy is currently essential for initial diagnosis. Reassessment of disease burden is frequently needed during episodes of active disease and when evaluating treatment efficacy. This review compares the role of Magnetic Resonance Enterography (MRE) and ileocolonoscopy in Crohn's disease management and whether cross-sectional imaging can replace invasive endoscopic tests. MRE can give information on the small bowel not visible at ileo-colonoscopy, and on extra-luminal complications. Evaluation of the bowel by MRE allows assessment of the submucosa and serosa, and thus transmural healing. MRE offers a well tolerated investigation and additional information on disease activity to better manage patients with Crohn's disease. Increasingly, there are a range of newer techniques such as diffusion weighted imaging, magnetisation transfer and motility MRI which provide greater information on fibrosis and predictors to treatment response which has been lacking despite the use of ileo-colonoscopy for several decades.
Collapse
Affiliation(s)
- Fumi Varyani
- NIHR Nottingham Biomedical Medical Centre, Nottingham University Hospitals NHS trust, Nottingham, United Kingdom
| | - Sunil Samuel
- NIHR Nottingham Biomedical Medical Centre, Nottingham University Hospitals NHS trust, Nottingham, United Kingdom.
| |
Collapse
|
9
|
Yoshida R, Yoshizako T, Maruyama M, Takinami Y, Shimojo Y, Tamaki Y, Kitagaki H. The value of CT findings for prognostic prediction of spontaneous superior mesenteric artery dissection. Acta Radiol 2019; 60:542-548. [PMID: 29950110 DOI: 10.1177/0284185118786056] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Spontaneous superior mesenteric artery (SMA) dissection is rare cause of acute abdomen. Time-dependent change of SMA dissection has not been established. PURPOSE To determine Sakamoto classification (SC) type of acute and chronic SMA dissection (aSMAD and cSMAD) to predict the treatment methods and outcome. MATERIAL AND METHODS From April 2003 to March 2017, unenhanced and contrast-enhanced CT were used to diagnose acute symptomatic or chronic asymptomatic SMA dissection in 25 consecutive patients without aortic dissection. Correlations between SCs and treatment methods and outcomes were investigated. RESULTS All 13 patients with aSMAD initially received conservative treatment. Initial SCs in aSMAD were type I = 1, type III = 9, and type IV = 3. Three of nine initial type III and two of three initial type IV changed to type I at follow-up. One of nine type III changed to type II at follow-up. Ohers did not change. One with initial type III required vascular repair, so the final SC was not available. Three patients required bowel resection. In cSMAD of 12 patients, the initial/final SC were type I and IV in ten and two patients, respectively, without change during follow-up. cSMAD was significantly older than aSMAD. The initial length of dissection of aSMAD was longer than in the cSMAD group. In aSMAD, the final length of dissection was significantly shorter than in the initial computed tomography scan. CONCLUSION Initial SC differed significantly between aSMAD and cSMAD. Initial SC types in aSMAD were type III and IV mainly, and changed during the observation period. In cSMAD, SC types were I and IV without change.
Collapse
Affiliation(s)
- Rika Yoshida
- Department of Radiology, Shimane University, Faculty of Medicine, Shimane, Japan
| | - Takeshi Yoshizako
- Department of Radiology, Shimane University, Faculty of Medicine, Shimane, Japan
| | - Minako Maruyama
- Department of Radiology, Shimane University, Faculty of Medicine, Shimane, Japan
| | - Yoshikazu Takinami
- Department of Emergency, Shimane University Faculty of Medicine, Shimane, Japan
| | - Yoshihide Shimojo
- Department of Acute care surgery, Shimane University Faculty of Medicine, Shimane, Japan
| | - Yukihisa Tamaki
- Department of Radiation Oncology, Shimane University, Faculty of Medicine, Shimane, Japan
| | - Hajime Kitagaki
- Department of Radiology, Shimane University, Faculty of Medicine, Shimane, Japan
| |
Collapse
|
10
|
Deepak P, Fowler KJ, Fletcher JG, Bruining DH. Novel Imaging Approaches in Inflammatory Bowel Diseases. Inflamm Bowel Dis 2019; 25:248-260. [PMID: 30010908 DOI: 10.1093/ibd/izy239] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Indexed: 12/12/2022]
Abstract
Inflammatory bowel diseases are chronic autoimmune conditions of the gastrointestinal tract, mainly grouped into ulcerative colitis or Crohn's disease. Traditionally, symptoms have been used to guide IBD management, but this approach is fatally flawed, as symptoms don't correlate with disease activity and often fail to predict disease complications, especially with Crohn's disease. Hence, there is increasing recognition of the need for treatment algorithms based on objective measures of bowel inflammation. In this review, we will focus on advancements in the endoscopic and radiological imaging armamentarium that allow detailed assessments from intestinal mucosa to mesentery.
Collapse
Affiliation(s)
- Parakkal Deepak
- Division of Gastroenterology, John T. Milliken Department of Medicine, Washington University in St. Louis School of Medicine, St. Louis, Missouri
| | - Kathryn J Fowler
- Department of Radiology, Washington University in St. Louis School of Medicine, St. Louis, Missouri
| | - Joel G Fletcher
- Division of Abdominal Imaging, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - David H Bruining
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota
| |
Collapse
|
11
|
Abstract
Computed tomography (CT) enterography is a noninvasive imaging modality with superb spatial and temporal resolution, specifically tailored to evaluate the small bowel. It has several advantages over other radiologic and optical imaging modalities, all of which serve as complementary investigations to one another. This article describes CTE technique, including dose reduction techniques, special considerations for the pediatric population, common technical and interpretive pitfalls, and reviews some of the more common small bowel entities seen with CTE.
Collapse
Affiliation(s)
- Shannon P Sheedy
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA.
| | - Amy B Kolbe
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Jeff L Fidler
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| |
Collapse
|
12
|
Deepak P, Fletcher JG, Fidler JL, Barlow JM, Sheedy SP, Kolbe AB, Harmsen WS, Therneau T, Hansel SL, Becker BD, Loftus EV, Bruining DH. Predictors of Durability of Radiological Response in Patients With Small Bowel Crohn's Disease. Inflamm Bowel Dis 2018; 24:1815-1825. [PMID: 29668921 PMCID: PMC6391864 DOI: 10.1093/ibd/izy074] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Indexed: 02/06/2023]
Abstract
BACKGROUND The long-term significance of radiological transmural response (TR) as a treatment goal at the first follow-up scan in small bowel Crohn's disease (CD) has been previously shown. We examined the durability of a long-term strategy of treating to a target of radiological TR and the influence of baseline predictors on the maintenance of TR. METHODS Small bowel CD patients between January 1, 2002, and December 31, 2014, were identified with serial computed tomography enterography (CTE)/magnetic resonance enterography (MRE) before and after initiation of therapy or on maintenance therapy. Overall TR (inflammatory lesions with/without strictures) w1as characterized by abdominal radiologists in up to 5 small bowel lesions per patient at each serial scan until last follow-up or small bowel resection, as response, partial response, or nonresponse. The rate of conversion between TR states and transition to surgery, including the effect of baseline patient/disease characteristics, was examined using a multistate model (mstate R-package). RESULTS CD patients (n = 150, 705 CTE/MRE) with a median of 4 CTE/MRE during 4.6 years of follow-up, 49% with ileal-only distribution, had 260 examined bowel segments. Conversion from response to partial response/nonresponse was 37.4% per year of follow-up with no transitions seen directly from response to surgery. Current smoking status (hazard ratio [HR], 2.2; 95% confidence interval [CI], 1.1-4.3) and internal penetrating disease at baseline scan (HR, 2.2; 95% CI, 1.2-4.1) were associated with a 2-fold increased risk of transition from partial response/nonresponse to surgery. CONCLUSIONS Achievement and maintenance of radiological response is associated with avoidance of small bowel surgery. Continued follow-up with CTE/MRE is recommended to identify loss of response, especially in current smokers and patients with internal penetrating disease at baseline CTE/MRE.
Collapse
Affiliation(s)
- Parakkal Deepak
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota,Department of Medicine, Division of Gastroenterology, Washington University School of Medicine, St. Louis, Missouri
| | - Joel G Fletcher
- Division of Abdominal Imaging, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Jeff L Fidler
- Division of Abdominal Imaging, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - John M Barlow
- Division of Abdominal Imaging, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Shannon P Sheedy
- Division of Abdominal Imaging, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Amy B Kolbe
- Division of Abdominal Imaging, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - William S Harmsen
- Division of Biomedical Statistics and Informatics, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Terry Therneau
- Division of Biomedical Statistics and Informatics, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Stephanie L Hansel
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Brenda D Becker
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - Edward V Loftus
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - David H Bruining
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota,Address correspondence to: David H. Bruining, MD, Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, 200 First Street, SW, Rochester, MN 55905 ()
| |
Collapse
|
13
|
Şerifoğlu İ, Öz İİ, Tosun A, Demir MK. İnce bağırsak obstrüksiyonlu hastaların tanısında bilgisayarlı tomografi bulgularının rolü. ACTA MEDICA ALANYA 2018. [DOI: 10.30565/medalanya.388620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
14
|
Kanasaki S, Furukawa A, Fumoto K, Hamanaka Y, Ota S, Hirose T, Inoue A, Shirakawa T, Nguyen LDH, Tulyeubai S. Acute Mesenteric Ischemia: Multidetector CT Findings and Endovascular Management. Radiographics 2018; 38:945-961. [DOI: 10.1148/rg.2018170163] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
15
|
Burlin S, Favaro LR, Bretas EAS, Taniguchi LS, Loch AP, Argollo MC, Ambrogini Junior O, D'Ippolito G. Using computed tomography enterography to evaluate patients with Crohn's disease: what impact does examiner experience have on the reproducibility of the method? Radiol Bras 2017; 50:13-18. [PMID: 28298727 PMCID: PMC5347498 DOI: 10.1590/0100-3984.2015.0131] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Objective To assess the impact that examiner experience has on the reproducibility and
accuracy of computed tomography (CT) enterography in the detection of
radiological signs in patients with Crohn's disease. Materials and Methods This was a retrospective, cross-sectional observational study involving the
analysis of CT enterography scans of 20 patients with Crohn's disease. The
exams were analyzed independently by two radiologists in their last year of
residence (duo I) and by two abdominal imaging specialists (duo II). The
interobserver agreement of each pair of examiners in identifying the main
radiological signs was calculated with the kappa test. The accuracy of the
examiners with less experience was quantified by using the consensus among
three experienced examiners as a reference. Results Duo I and duo II obtained a similar interobserver agreement, with a moderate
to good correlation, for mural hyperenhancement, parietal thickening, mural
stratification, fat densification, and comb sign (kappa: 0.45-0.64). The
less experienced examiners showed an accuracy > 80% for all signs, except
for lymph nodes and fistula, for which it ranged from 60% to 75%. Conclusion Less experienced examiners have a tendency to present a level of
interobserver agreement similar to that of experienced examiners in
evaluating Crohn's disease through CT enterography, as well as showing
satisfactory accuracy in identifying most radiological signs of the
disease.
Collapse
Affiliation(s)
- Stênio Burlin
- MD, Radiologist in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Larissa Rossini Favaro
- MD, Radiologist, Specialist in Abdominal Imaging in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Elisa Almeida Sathler Bretas
- MD, Radiologist, Graduate Student in Abdominal Imaging in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Lincoln Seiji Taniguchi
- MD, Radiologist, Specialist in Abdominal Imaging in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Ana Paula Loch
- Pharmacist, Graduate Student in Preventive Medicine at the Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP, Brazil
| | - Marjorie Costa Argollo
- MD, Graduate Student in Clinical Gastroenterology, Discipline of Clinical Medicine, Department of Medicine of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Orlando Ambrogini Junior
- PhD, Affiliate Professor, Discipline of Clinical Medicine, Department of Medicine of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Giuseppe D'Ippolito
- Tenured Adjunct Professor in the Department of Diagnostic Imaging of the Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| |
Collapse
|
16
|
The first joint ESGAR/ ESPR consensus statement on the technical performance of cross-sectional small bowel and colonic imaging. Eur Radiol 2016; 27:2570-2582. [PMID: 27757521 PMCID: PMC5408044 DOI: 10.1007/s00330-016-4615-9] [Citation(s) in RCA: 109] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2016] [Revised: 08/11/2016] [Accepted: 09/15/2016] [Indexed: 12/28/2022]
Abstract
Objectives To develop guidelines describing a standardised approach to patient preparation and acquisition protocols for magnetic resonance imaging (MRI), computed tomography (CT) and ultrasound (US) of the small bowel and colon, with an emphasis on imaging inflammatory bowel disease. Methods An expert consensus committee of 13 members from the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) and European Society of Paediatric Radiology (ESPR) undertook a six-stage modified Delphi process, including a detailed literature review, to create a series of consensus statements concerning patient preparation, imaging hardware and image acquisition protocols. Results One hundred and fifty-seven statements were scored for agreement by the panel of which 129 statements (82 %) achieved immediate consensus with a further 19 (12 %) achieving consensus after appropriate modification. Nine (6 %) statements were rejected as consensus could not be reached. Conclusions These expert consensus recommendations can be used to help guide cross-sectional radiological practice for imaging the small bowel and colon. Key points • Cross-sectional imaging is increasingly used to evaluate the bowel • Image quality is paramount to achieving high diagnostic accuracy • Guidelines concerning patient preparation and image acquisition protocols are provided
Collapse
|
17
|
Endoscopy and cross-sectional imaging for assessing Crohn׳s disease activity. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2016; 18:123-130. [PMID: 28458507 DOI: 10.1016/j.tgie.2016.08.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Crohn's disease (CD) is principally characterized by chronic and recurrent inflammation of the gastrointestinal tract, most commonly found in the ileo-colonic region. The chronicity and severity of intestinal inflammation together contribute to progressive, cumulative, deep, transmural intestinal damage, including stricturing, obstruction, abscesses, and fistulae. Both intestinal inflammation and its chronic complications result in a range of symptoms subsequently leading to patient presentations with diarrhea, abdominal pain, and anemia related to intestinal blood loss. Measuring disease activity and severity are essential for decision of treatment intensity early in the disease course and longitudinal monitoring of therapeutic efficacy. This review will summarize the transition from subjective symptoms driving disease activity indices, into increasingly objective and quantitative measures of intestinal injury by direct mucosal assessment (endoscopy), cross-sectional imaging, and surrogate biomarkers. Specific commentary on intestinal stricture and perianal fistula assessment and management are presented in accompanying sections of this series.
Collapse
|
18
|
Radiological Response Is Associated With Better Long-Term Outcomes and Is a Potential Treatment Target in Patients With Small Bowel Crohn's Disease. Am J Gastroenterol 2016; 111:997-1006. [PMID: 27166131 DOI: 10.1038/ajg.2016.177] [Citation(s) in RCA: 103] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Accepted: 04/13/2016] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Crohn's disease (CD) management targets mucosal healing on ileocolonoscopy as a treatment goal. We hypothesized that radiologic response is also associated with better long-term outcomes. METHODS Small bowel CD patients between 1 January 2002 and 31 October 2014 were identified. All patients had pre-therapy computed tomography enterography (CTE)/magnetic resonance enterography (MRE) with follow-up CTE or MRE after 6 months, or 2 CTE/MREs≥6 months apart while on maintenance therapy. Radiologists characterized inflammation in up to five small bowel lesions per patient. At second CTE/MRE, complete responders had all improved lesions, non-responders had worsening or new lesions, and partial responders had other scenarios. CD-related outcomes of corticosteroid usage, hospitalization, and surgery were assessed using Kaplan-Meier survival analysis and multivariable Cox models. RESULTS CD patients (n=150), with a median disease duration of 9 years, had 223 inflamed small bowel segments (76 with strictures and 62 with penetrating, non-perianal disease), 49% having ileal distribution. Fifty-five patients (37%) were complete radiologic responders, 39 partial (26%), and 56 non-responders (37%). In multivariable Cox models, complete and partial response decreased risk for steroid usage by over 50% (hazard ratio (HR)s: 0.37 (95% confidence interval (CI), 0.21-0.64); 0.45 (95% CI, 0.26-0.79)), and complete response decreased the risk of subsequent hospitalizations and surgery by over two-thirds (HRs: HR, 0.28 (95% CI, 0.15-0.50); HR, 0.34 (95% CI, 0.18-0.63)). CONCLUSIONS Radiological response to medical therapy is associated with significant reductions in long-term risk of hospitalization, surgery, or corticosteroid usage among small bowel CD patients. These findings suggest the significance of radiological response as a treatment target.
Collapse
|
19
|
Abstract
OBJECTIVE The purpose of this article is to describe our approach to contrast-enhanced abdominal MRI in patients with nontraumatic abdominal pain and suspected appendicitis. We aim to share our experience on the advantages, pearls, and pitfalls of MRI in this clinical setting, in comparison with CT and ultrasound. CONCLUSION We present some typical cases of appendicitis and alternative diagnoses in patients presenting with acute nontraumatic abdominal pain.
Collapse
|
20
|
Frye JM, Hansel SL, Dolan SG, Fidler JL, Song LMWK, Barlow JM, Smyrk TC, Flicek KT, Hara AK, Bruining DH, Fletcher JG. NSAID enteropathy: appearance at CT and MR enterography in the age of multi-modality imaging and treatment. ACTA ACUST UNITED AC 2016; 40:1011-25. [PMID: 25666969 DOI: 10.1007/s00261-015-0367-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
CT and MR enterography and capsule endoscopy are increasingly used as routine diagnostic tests for patients with potential small bowel disorders and obscure gastrointestinal bleeding. Non-steroidal anti-inflammatory drugs (NSAIDs) are commonly used drugs that disrupt prostaglandin synthesis and result in a variety of localized complications within the small bowel ranging from ulcer formation to characteristic circumferential strictures, or diaphragms. NSAID enteropathy encompasses this spectrum of acute and chronic inflammatory sequelae, and is associated with typical findings at capsule endoscopy and surgery. Herein we review the typical clinical presentation of NSAID enteropathy, in addition to its endoscopic appearances, focusing on imaging findings at cross-sectional enterography. Multiple, short-segment strictures are the hallmarks of imaging diagnosis. Strictures may have minimal hyperenhancement or wall thickening, but these findings are typically symmetric and circumferential with respect to the bowel lumen. Multifocal Crohn's strictures, and occasionally radiation-induced strictures or adhesions, will mimic NSAID diaphragms. Multi-phase or multi-sequence imaging at CT and MR enterography increase diagnostic confidence in stricture presence. Strategies for subsequent workup and therapy after enterography are also discussed. Given the frequent use of NSAIDs and typical appearance of these strictures, knowledge of characteristic imaging findings can be particularly useful when evaluating patients with anemia and recurrent small bowel obstruction.
Collapse
Affiliation(s)
- Judson M Frye
- Department of Radiology, Mayo Clinic Health System, La Crosse, WI, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Makara M, Chau J, Hall E, Kloeppel H, Podadera J, Barrs V. EFFECTS OF TWO CONTRAST INJECTION PROTOCOLS ON FELINE AORTIC AND HEPATIC ENHANCEMENT USING DYNAMIC COMPUTED TOMOGRAPHY. Vet Radiol Ultrasound 2015; 56:367-73. [PMID: 25640846 DOI: 10.1111/vru.12239] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Accepted: 11/19/2014] [Indexed: 11/28/2022] Open
Abstract
This prospective study compared aortic and hepatic enhancement achieved using a contrast injection protocol with a fixed rate of 5 ml/s vs. that achieved using a protocol with fixed injection duration of 20 s in eight cats. Cats were assigned into two groups (Group 1, rate 5 ml/s; Group 2, duration 20 s). The dose of contrast was the same in both groups (740 mgI/kg). Regions of interest (ROI) were drawn in the aorta and liver for transverse scans acquired at the hepatic hilus. Time to peak aortic enhancement occurred significantly earlier in Group 1 (M = 11s, SD = 1.63) than in Group 2 (M = 25.5 s, SD = 2.51). Peak aortic enhancement was significantly higher in Group 1 (M = 1906.51 HU, SD = 368.64) than in Group 2 (M = 745.08 HU, SD = 201.84). Duration of aortic enhancement equal to or above 300 HU was statistically longer in Group 2 (M = 24.5 s, SD = 8.39) than in Group 1 (M = 10 s, SD = 1.63). There were no significant differences in time to peak liver enhancement, peak liver enhancement, or duration of hepatic arterial phase between groups. Findings supported the hypothesis that longer injection duration results in a broader bolus geometry with a longer time to peak and a lower peak aortic enhancement in cat. This strong influence of injection duration on timing of aortic enhancement may help future users optimize protocols for CT angiography of the aorta and multiphasic evaluation of the liver, pancreas, and small intestine.
Collapse
Affiliation(s)
- Mariano Makara
- Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia
| | - Jennifer Chau
- Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia
| | - Evelyn Hall
- Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia
| | - Heide Kloeppel
- Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia
| | - Juan Podadera
- Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia
| | - Vanessa Barrs
- Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia
| |
Collapse
|
22
|
Barral M, Boudiaf M, Dohan A, Hoeffel C, Camus M, Pautrat K, Fishman E, Cohen S, Soyer P. MDCT of acute colitis in adults: An update in current imaging features. Diagn Interv Imaging 2015; 96:133-49. [DOI: 10.1016/j.diii.2014.04.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
23
|
Fowler KJ, Dassopoulos T, Raptis C. Magnetic resonance enterography in the evaluation of Crohn's disease: a primer for the gastroenterologist. Inflamm Bowel Dis 2014; 20:2179-88. [PMID: 25054338 DOI: 10.1097/mib.0000000000000132] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The assessment of disease location, severity, and complications is critical in guiding the choice of Crohn's disease therapy. Cross-sectional imaging studies have therefore had a paramount role in accurately staging Crohn's disease. Traditionally, computed tomography was the test of choice in confirming/excluding strictures, fistulae, and abscesses. Magnetic resonance imaging is now replacing computed tomography because it eliminates radiation risks. This review provides a primer for the gastroenterologist on magnetic resonance enterography in Crohn's disease.
Collapse
Affiliation(s)
- Kathryn J Fowler
- *Department of Radiology, and †Department of Internal Medicine, Gastroenterology Division, Washington University, St Louis, Missouri
| | | | | |
Collapse
|
24
|
He B, Gong S, Hu C, Fan J, Qian J, Huang S, Cui L, Ji Y. Obscure gastrointestinal bleeding: diagnostic performance of 64-section multiphase CT enterography and CT angiography compared with capsule endoscopy. Br J Radiol 2014; 87:20140229. [PMID: 25248830 DOI: 10.1259/bjr.20140229] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVE To compare the diagnostic capabilities between capsule endoscopy (CE) and multislice CT (MSCT) enterography in combination with MSCT angiography for assessment of obscure gastrointestinal bleeding (OGIB). METHODS A total of 127 patients with OGIB were looked at in this study. 82 patients (aged 42.7 ± 19.1 years; 34 males) were assigned to receive MSCT diagnosis and 67 patients to (aged 53.9 ± 16.2 years; 28 males) receive CE diagnosis. Among them, 22 patients (aged 54.1 ± 19.1 years; 12 males) received both examinations. Oral isotonic mannitol and intramuscular injection of anisodamine were performed; non-ionic contrast (iopromide, 370 mg I ml(-1)) was intravenously administered; and then multiphase scanning was conducted at arterial, small intestinal and portal venous phases in MSCT. The results were compared with findings of reference standards including double balloon enteroscopy, digital subtraction angiography, intraoperative pathological examination and/or clinical diagnosis. RESULTS Administration of anisodamine markedly increased the satisfaction rate of bowel filling (94.67% vs 28.57%; p < 0.001) but not the diagnostic yield (p = 0.293) of MSCT. Compared with MSCT, CE showed an improved overall diagnostic yield (68.66% vs 47.56%; p = 0.010), which was also observed in overt bleeding patients (i.e. patients with continued passage of visible blood) (76.19% vs 51.02%; p = 0.013) and in patients aged younger than 40 years of age (85% vs 51.28%; p = 0.024). However, CE had similar positive rates to MSCT (p > 0.05). Among the 22 cases in whom both examinations were conducted, CE showed no significantly different diagnostic capability compared with MSCT (p = 0.4597). CONCLUSION Both CE and MSCT are safe and effective diagnostic methods for OGIB. ADVANCES IN KNOWLEDGE CE is preferred for overt bleeding or patients aged younger than 40 years. The combined use of CE and MSCT is recommended in OGIB diagnosis.
Collapse
Affiliation(s)
- B He
- 1 Department of Radiology, The First Affiliated Hospital of Soochow University, Jiangsu, China
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Smolinski S, George M, Dredar A, Hayes C, Rakita D. Magnetic resonance enterography in evaluation and management of children with Crohn's disease. Semin Ultrasound CT MR 2014; 35:331-48. [PMID: 25129211 DOI: 10.1053/j.sult.2014.05.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The role of radiologic evaluation in Crohn's disease (CD) has undergone a recent paradigm shift in which the radiologist adds value to the multidisciplinary team by longitudinally assessing therapeutic response and identifying treatment-modifying subtypes, such as fibrostenotic or fistulizing disease. Magnetic resonance enterography (MRE) has become the primary imaging modality used. The combination of multiplanar, multiparametric, and multiphasic contrast-enhanced imaging with the high spatial resolution and very high tissue contrast of MR imaging allows for detailed evaluation of intra-abdominal pathology, without the risk of cumulative radiation exposure. MRE provides the benefit of a complete evaluation of mural, extramural, and even extraintestinal manifestations and complications of CD in a single examination. Cine motility sequences and diffusion-weighted imaging may further increase sensitivity and specificity. MRE represents an ideal imaging modality for initial evaluation, assessment of therapeutic response, and evaluation of complications in patients with CD.
Collapse
Affiliation(s)
- Sara Smolinski
- Department of Radiology, Baystate Medical Center, Springfield, MA.
| | - Michael George
- Department of Radiology, Baystate Medical Center, Springfield, MA
| | | | - Christopher Hayes
- Department of Pediatric Gastroenterology and Nutrition, Baystate Medical Center, Springfield, MA
| | - Dmitry Rakita
- Department of Radiology, Baystate Medical Center, Springfield, MA
| |
Collapse
|
26
|
Fidler JL, Fletcher JG, Bruining DH, Trenkner SW. Current status of CT, magnetic resonance, and barium in inflammatory bowel disease. Semin Roentgenol 2014; 48:234-44. [PMID: 23796374 DOI: 10.1053/j.ro.2013.03.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Jeff L Fidler
- Department of Radiology, Mayo Clinic, Rochester, MN, USA.
| | | | | | | |
Collapse
|
27
|
Del Gaizo AJ, Fletcher JG, Yu L, Paden RG, Spencer GC, Leng S, Silva AM, Fidler JL, Silva AC, Hara AK. Reducing radiation dose in CT enterography. Radiographics 2014; 33:1109-24. [PMID: 23842974 DOI: 10.1148/rg.334125074] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.
Collapse
Affiliation(s)
- Andrew J Del Gaizo
- Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, Scottsdale, AZ 85259, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
Due to advances in technology, magnetic resonance is an increasingly popular method for evaluating the small bowel and colon because of the lack of radiation, wealth of information provided by the images, and growing demand from gastroenterologists, surgeons, and oncologists. Careful attention to proper technique, however, is necessary to obtain high-quality images. Factors that need to be considered for successful magnetic resonance of the bowel include method for administration of oral or rectal contrast, patient positioning, need for antiperistaltic medication, and imaging sequences and planes.
Collapse
Affiliation(s)
- Cynthia S Santillan
- Department of Radiology, University of California San Diego, 200 West Arbor Drive #8756, San Diego, CA 92120, USA.
| |
Collapse
|
29
|
O'Neill SB, Mc Laughlin PD, Crush L, O'Connor OJ, Mc Williams SR, Craig O, Mc Garrigle AM, O'Neill F, Bye J, Ryan MF, Shanahan F, Maher MM. A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn's disease. Eur Radiol 2013; 23:2503-12. [PMID: 23740025 DOI: 10.1007/s00330-013-2858-2] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 03/03/2013] [Accepted: 03/17/2013] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Iterative reconstruction (IR) allows diagnostic CT imaging with less radiation exposure than filtered back projection (FBP). We studied an IR low-dose CT abdomen/pelvis (LDCTAP) protocol, designed to image at an effective dose (ED) approximating 1 mSv in patients with Crohn's disease (CD). METHODS Forty patients, mean age 37 ± 13.4 years (range 17-69), with CD underwent two synchronous CT protocols (conventional-dose (CDCTAP) and LDCTAP). CDCTAP and LDCTAP images were compared for diagnostic acceptability, yield, image quality and ED (in millisieverts). The optimal level of IR for LDCTAP was also studied. RESULTS LDCTAP yielded a mean ED of 1.3 ± 0.8 mSv compared with 4.7 ± 2.9 mSv for CDCTAP, reducing ED by 73.7 ± 3.3 % (mean dose reduction, 3.5 ± 2.1 mSv; P < 0.001) and dose length product by 73.6 ± 2.6 % (P < 0.001). Sub-millisievert (0.84 mSv) imaging was performed for patients with a body mass index (BMI) less than 25 (i.e. 63 % of our cohort). LDCTAP resulted in increased image noise and reduced diagnostic acceptability compared with CDCTAP despite use of IR, but detection of extra-luminal complications was comparable. CONCLUSION Patients with suspected active CD can be adequately imaged using LDCTAP, yielding comparable information regarding extent, activity and complications of CD compared with CDCTAP, but with 74 % less dose. LDCTAP at doses equivalent to that of two abdominal radiographs represents a feasible alternative to CDCTAP. KEY POINTS • Radiation dose is a concern when imaging patients with Crohn's disease. • New techniques allow low-dose abdominopelvic CT with acceptable image quality. • Using hybrid iterative reconstruction, its diagnostic yield compares well with that of conventional CT. • Sub-millisievert CT of patients with Crohn's disease appears technically and clinically feasible.
Collapse
Affiliation(s)
- Siobhan B O'Neill
- Department of Radiology, Cork University Hospital, Wilton, Cork, Ireland
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Yu C, Xiao XZ. Application of MSCT enterography in the evaluation of Crohn's disease. Shijie Huaren Xiaohua Zazhi 2013; 21:233-238. [DOI: 10.11569/wcjd.v21.i3.233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The assessment of small bowel abnormalities has always been a challenging task for radiologists and gastroenterologists. Conventional radiologic and endoscopic evaluations are often limited by the length and caliber of small bowel loops. CT enterography, a robust new method with high spatial and isotropic spatial resolution, is a variant of conventional CT technique optimized for the evaluation of the small bowel. Crohn's disease is an inflammatory disease which can involve different areas of the gastrointestinal tract, and it was characterized by segmental and transmural inflammation, with the terminal ileum being the most common site of involvement. CT enterography is well tolerated by these patients and enables accurate, efficient assessment of lesions arising from the small bowel wall or surrounding organs. In this article, we discuss the principle of CT enterography and its use in the evaluation of Crohn's disease.
Collapse
|
31
|
Ilangovan R, Burling D, George A, Gupta A, Marshall M, Taylor SA. CT enterography: review of technique and practical tips. Br J Radiol 2012; 85:876-86. [PMID: 22553291 PMCID: PMC3474054 DOI: 10.1259/bjr/27973476] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2011] [Revised: 12/01/2011] [Accepted: 12/06/2011] [Indexed: 02/06/2023] Open
Abstract
CT enterography is a new non-invasive imaging technique that offers superior small bowel visualisation compared with standard abdomino-pelvic CT, and provides complementary diagnostic information to capsule endoscopy and MRI enterography. CT enterography is well tolerated by patients and enables accurate, efficient assessment of pathology arising from the small bowel wall or surrounding organs. This article reviews the clinical role of CT enterography, and offers practical tips for optimising technique and accurate interpretation.
Collapse
Affiliation(s)
- R Ilangovan
- Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK
| | | | | | | | | | | |
Collapse
|
32
|
Bruining DH, Siddiki HA, Fletcher JG, Sandborn WJ, Fidler JL, Huprich JE, Mandrekar JN, Harmsen WS, Evans PE, Faubion WA, Hanson KA, Ingle SB, Pardi DS, Schroeder KW, Tremaine WJ, Loftus EV. Benefit of computed tomography enterography in Crohn's disease: effects on patient management and physician level of confidence. Inflamm Bowel Dis 2012; 18:219-25. [PMID: 21337477 DOI: 10.1002/ibd.21683] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2011] [Accepted: 01/18/2011] [Indexed: 12/09/2022]
Abstract
BACKGROUND Computed tomographic enterography (CTE) has been shown to have a high sensitivity and specificity for active small bowel inflammation. There are only sparse data on the effect of CTE results on Crohn's disease (CD) patient care. METHODS We prospectively assessed 273 patients with established or suspected CD undergoing a clinically indicated CTE. Providers were asked to complete pre- and postimaging questionnaires regarding proposed clinical management plans and physician level of confidence (LOC) for the presence or absence of active small bowel disease, fistula(s), abscess(es), or stricturing disease. Correlative clinical, serologic, and histologic data were recorded. Following revelation of CTE results, providers were questioned if CTE altered their management plans, and whether LOC changes were due to CTE findings (on a 5-point scale). RESULTS CTE altered management plans in 139 cases (51%). CTE changed management in 70 (48%) of those with established disease, prompting medication changes in 35 (24%). Management changes were made post-CTE in 69 (54%) of those with suspected CD, predominantly due to excluding CD (36%). CTE-perceived changes in management were independent of clinical, serologic, and histologic findings (P < 0.0001). Clinically meaningful LOC changes (2 or more points) were observed in 212 (78%). CONCLUSIONS CTE is a clinically useful examination, altering management plans in nearly half of patients with CD, while increasing physician LOC for the detection of small bowel inflammation and penetrating disease. These findings further support the use of CTE in CD management algorithms.
Collapse
Affiliation(s)
- David H Bruining
- Division of Gastroenterology & Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Bruining DH, Loftus EV, Ehman EC, Siddiki HA, Nguyen DL, Fidler JL, Huprich JE, Mandrekar JN, Harmsen WS, Sandborn WJ, Fletcher JG. Computed tomography enterography detects intestinal wall changes and effects of treatment in patients with Crohn's disease. Clin Gastroenterol Hepatol 2011; 9:679-683.e1. [PMID: 21621641 DOI: 10.1016/j.cgh.2011.04.025] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2010] [Revised: 04/04/2011] [Accepted: 04/10/2011] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS The use of computed tomography enterography (CTE) in patients with Crohn's disease has increased. However, there is little data available on how radiologic parameters of active disease change during treatment with infliximab and whether these changes correspond to symptoms, serum biomarkers, or endoscopic appearance. METHODS We performed a retrospective study of patients with Crohn's disease who had undergone serial CTE imaging while receiving infliximab. Lesions were defined as improved if their enhancement or length decreased without worsening of other parameters. Patients were grouped as responders (all lesions improved), partial responders (some lesions improved), and nonresponders (worsening or no changes in all lesions). Of the 63 patients identified (47% female), the median age was 37.7 years, the median disease duration was 7.6 years, and the median time between initial and first follow-up CTE was 356 days (interquartile range, 215-630). RESULTS Of 105 lesions, 52 (49.5%) improved, 11 (10.5%) remained unchanged, and 42 (40.0%) worsened. Per patient, 28 (44.4%) were responders, 12 (19.0%) were partial responders, and 23 (36.5%) were nonresponders. The radiologic response had poor-to-fair agreement with symptoms, endoscopic appearance, and levels of C-reactive protein at time of second CTE (κ = 0.26, 0.07, and 0.30 respectively). CONCLUSIONS Radiologic improvement was observed in 63.4% of patients with Crohn's disease who received infliximab therapy, despite a study design that was likely biased toward nonresponders. Radiologic response was not in good agreement with clinical symptoms, serum biomarkers, or endoscopic appearance; CTE might be used as a complementary approach to identify mural healing or inflammation not detected by other methods.
Collapse
Affiliation(s)
- David H Bruining
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota 55905, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Fletcher JG, Fidler JL, Bruining DH, Huprich JE. New concepts in intestinal imaging for inflammatory bowel diseases. Gastroenterology 2011; 140:1795-806. [PMID: 21530746 DOI: 10.1053/j.gastro.2011.02.013] [Citation(s) in RCA: 101] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2010] [Revised: 02/08/2011] [Accepted: 02/11/2011] [Indexed: 12/26/2022]
Abstract
In the last decade, multiple imaging technologies have been developed that improve visualization of the mucosal, mural, and perienteric inflammation associated with inflammatory bowel diseases. Whereas these technologies have traditionally been used to detect and stage suspected enteric inflammation, we review new, emerging roles in detecting clinically occult inflammation (in asymptomatic patients) and inflammatory complications, predicting response prior to therapy, assessing response after therapy, and enteric healing. We compare the relative performance of these technologies in detecting inflammation, focusing on their advantages and disadvantages and how they might complement each other. We also discuss their potential benefits for patients and clinical trials, reviewing technologic developments and areas of research that could provide important insights into the pathophysiology of inflammatory bowel diseases-related enteric inflammation.
Collapse
Affiliation(s)
- Joel G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
| | | | | | | |
Collapse
|
35
|
Siddiki H, Fletcher JG, Hara AK, Kofler JM, McCollough CH, Fidler JL, Guimaraes L, Huprich JE, Sandborn WJ, Loftus EV, Mandrekar J, Bruining DH. Validation of a lower radiation computed tomography enterography imaging protocol to detect Crohn's disease in the small bowel. Inflamm Bowel Dis 2011; 17:778-86. [PMID: 20848546 DOI: 10.1002/ibd.21364] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
BACKGROUND The purpose was to validate a lower radiation dose computed tomography enterography (CTE) imaging protocol to detect the presence of Crohn's disease (CD) in the small bowel using two different reference standards and to identify a prediction model based on CTE signs for the presence of active CD. METHODS This retrospective study included patients with known or suspected CD who underwent CTE between January and October 2006 according to a lower radiation dose protocol. Two gastrointestinal radiologists blindly and independently classified each CTE as being active or inactive. Reference standards included ileocolonoscopy ± biopsy and a comprehensive clinical reference standard (retrospectively created by a gastroenterologist, also including history, physical, follow-up course, and subsequent endoscopy, imaging, or surgery). Logistic regression was used to identify CTE findings that predicted the presence of active CD based on the combined clinical reference standard. RESULTS In all, 137 patients underwent CTE and ileocolonoscopy. Using an endoscopic reference standard, the sensitivity of CTE to detect active CD for the two readers was 81% and 89%, respectively. Using the clinical reference standard, the sensitivity of CTE to detect active CD was 89% and 98%, respectively. For both readers the sensitivity of CTE increased by 8%-9% when using the comprehensive reference standard. Multivariate analysis showed that a combination of mural thickness and hyperenhancement best predicted active CD (area under the curve [AUC] = 0.92-0.93, P < 0.0001). CONCLUSIONS Lower radiation dose CTE exams are sensitive for the detection of active small bowel CD. The combination of mural thickness and hyperenhancement are the best radiologic predictors of active CD.
Collapse
Affiliation(s)
- Hassan Siddiki
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Guimarães LS, Fletcher JG, Yu L, Huprich JE, Fidler JL, Manduca A, Ramirez-Giraldo JC, Holmes DR, McCollough CH. Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography: optimization and validation. Acad Radiol 2010; 17:1203-10. [PMID: 20832023 DOI: 10.1016/j.acra.2010.07.001] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2010] [Revised: 07/04/2010] [Accepted: 07/05/2010] [Indexed: 11/27/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of this study was to optimize and validate projection-space denoising (PSDN) strategies for application to 80-kV computed tomographic (CT) data to achieve 50% dose reduction. MATERIALS AND METHODS Image data obtained at 80 kV (mean CT dose index volume, 7.9 mGy) from dual-source, dual-energy CT enterographic (CTE) exams in 42 patients were used. For each exam, nine 80 kV image data sets were reconstructed using PSDN (three levels of intensity) with or without image-based denoising and compared to commercial reconstruction kernels. For optimization, qualitative analysis selected optimal denoising strategies, with quantitative analysis measuring image contrast, noise, and sharpness (full width at half maximum bowel wall thickness, maximum CT number gradient). For validation, two radiologists examined image quality, comparing low-dose 80-kV optimally denoised images to full-dose mixed-voltage images. RESULTS PSDN algorithms generated the best 80-kV image quality (41 of 42 patients), while the commercial kernels produced the worst (39 of 42) (P < .001). Overall, 80-kV PSDN approaches resulted in higher contrast (mean, 332 vs 290 Hounsfield units), slightly less noise (mean, 20 vs 26 Hounsfield units), but slightly decreased image sharpness (relative bowel wall thickness, 1.069 vs 1.000) compared to full-dose mixed-voltage images. Mean image quality scores for full-dose CTE images were 4.9 compared to 4.5 for optimally denoised half-dose 80-kV CTE images and 3.1 for nondenoised 80-kV CTE images (P < .001). CONCLUSION Optimized denoising strategies improve the quality of 80-kV CTE images such that CT data obtained at 50% of routine dose levels approaches the image quality of full-dose exams.
Collapse
|
37
|
Soyer P, Boudiaf M, Sirol M, Dray X, Aout M, Duchat F, Vahedi K, Fargeaudou Y, Martin-Grivaud S, Hamzi L, Vicaut E, Rymer R. Suspected anastomotic recurrence of Crohn disease after ileocolic resection: evaluation with CT enteroclysis. Radiology 2010; 254:755-64. [PMID: 20177090 DOI: 10.1148/radiol.09091165] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
PURPOSE To determine the utility of computed tomographic (CT) enteroclysis for characterization of the status of the anastomotic site in patients with Crohn disease who had previously undergone ileocolic resection. MATERIALS AND METHODS Written informed consent was prospectively obtained from all patients, and the institutional review board approved the study protocol. CT enteroclysis findings in 40 patients with Crohn disease who had previously undergone ileocolic resection were evaluated independently by two readers. Endoscopic findings, histopathologic findings, and/or the Crohn disease activity index was the reference standard. Interobserver agreement between the two readers was calculated with kappa statistics. Associations between CT enteroclysis findings and anastomotic site status were assessed at univariate analysis. The sensitivity, specificity, and accuracy of CT enteroclysis, with corresponding 95% confidence intervals (CIs), for the diagnosis of normal versus abnormal anastomosis and the diagnosis of anastomotic recurrence versus fibrostenosis were estimated. RESULTS Interobserver agreement regarding CT enteroclysis criteria was good to perfect (kappa = 0.72-1.00). At univariate analysis, stratification and anastomotic wall thickening were the two most discriminating variables in the differentiation between normal and abnormal anastomoses (P < .001). Stratification (P < .001) and the comb sign (P = .026) were the two most discriminating variables in the differentiation between anastomotic recurrence and fibrostenosis. In the diagnosis of anastomotic recurrence, severe anastomotic stenosis was the most sensitive finding (95% [20 of 21 patients]; 95% CI: 76.18%, 99.88%), both comb sign and stratification had 95% specificity (18 of 19 patients; 95% CI: 73.97%, 99.87%), and stratification was the most accurate finding (92% [37 of 40 patients]; 95% CI: 79.61%, 98.43%). In the diagnosis of fibrostenosis, both severe anastomotic stenosis and anastomotic wall thickening were 100% sensitive (eight of eight patients; 95% CI: 63.06%, 100.00%), and using an association among five categorical variables, including severe anastomotic stenosis, anastomotic wall thickening with normal or mild mucosal enhancement, absence of comb sign, and absence of fistula, yielded 88% sensitivity (seven of eight patients; 95% CI: 47.35%, 99.68%), 97% specificity (31 of 32 patients; 95% CI: 83.78%, 99.92%), and 95% accuracy (38 of 40 patients; 95% CI: 83.08%, 99.39%). CONCLUSION CT enteroclysis yields objective and relatively specific morphologic criteria that help differentiate between recurrent disease and fibrostenosis at the anastomotic site after ileocolic resection for Crohn disease. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.09091165/-/DC1.
Collapse
Affiliation(s)
- Philippe Soyer
- Departments of Abdominal and Interventional Imaging and Digestive Diseases, Lariboisière-AP-HP-GHU Nord and Diderot-Paris 7 University, 2 rue Ambroise Paré, 75475 Paris cedex 10, France.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Abstract
Conventional radiologic and endoscopic evaluations of the small bowel are often limited by the length, caliber, and motility of the small bowel loops. The development of new multidetector-row CT scanners, with faster scan times and isotropic spatial resolution, allows high-resolution multiphasic and multiplanar assessment of the bowel, bowel wall, and lumen. CT Enterography (CTE) is a variant of routine abdominal scanning, geared toward more sustained bowel filling with oral contrast material, and the use of multiplanar images, that can enhance gastrointestinal (GI) tract imaging. This article examines the techniques and clinical applications of CTE in comparison with CT enteroclysis, focusing on Crohn disease, obscure GI bleeding, GI tumors, acute abdominal pain, and bowel obstruction.
Collapse
Affiliation(s)
- Giulia A Zamboni
- Istituto di Radiologia, Policlinico GB Rossi, P.le L.A. Scuro 10, 37134 Verona, Italy.
| | | |
Collapse
|
39
|
Brodoefel H, Bethge W, Vogel M, Fenchel M, Faul C, Wehrmann M, Claussen C, Horger M. Early and late-onset acute GvHD following hematopoietic cell transplantation: CT features of gastrointestinal involvement with clinical and pathological correlation. Eur J Radiol 2010; 73:594-600. [DOI: 10.1016/j.ejrad.2009.01.011] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2008] [Accepted: 01/07/2009] [Indexed: 01/03/2023]
|
40
|
Soyer P, Boudiaf M, Dray X, Fargeaudou Y, Vahedi K, Aout M, Vicaut E, Hamzi L, Rymer R. CT enteroclysis features of uncomplicated celiac disease: retrospective analysis of 44 patients. Radiology 2009; 253:416-24. [PMID: 19864528 DOI: 10.1148/radiol.2532090533] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
PURPOSE To describe the computed tomographic (CT) enteroclysis features of uncomplicated celiac disease (CD) and to determine the most indicative appearance of this condition by using a retrospective case-control study. MATERIALS AND METHODS This study had institutional review board approval. The CT enteroclysis examinations of 44 consecutive patients with proved uncomplicated CD (21 men, 23 women; mean age, 44.45 years) were reviewed by two blinded readers and compared with those obtained in 44 control subjects (21 men, 23 women; mean age, 44.48 years), who were matched for sex and age. Comparisons were calculated by using univariate analysis. RESULTS Reversed jejunoileal fold pattern had the highest specificity (100%; 44 of 44; 95% confidence interval [CI]: 91.96%, 100%) and was the most discriminating independent variable for the diagnosis of uncomplicated CD (odds ratio, 39.9; P < .0001) but had a sensitivity of 63.64% (28 of 44; 95% CI: 47.77%, 77.59%). Ileal fold thickening, vascular engorgement, and splenic atrophy were other variables that strongly correlated with the presence of uncomplicated CD. CONCLUSION CT enteroclysis may help establish a diagnosis of uncomplicated CD and may clarify the cause of nonspecific gastrointestinal symptoms in patients with unknown CD. However, future prospective trials are needed to determine the actual value of CT enteroclysis in patients with CD and validate the clinical usefulness of CT enteroclysis in the detection of unknown uncomplicated CD.
Collapse
Affiliation(s)
- Philippe Soyer
- Department of Abdominal Imaging, and Clinical Research Unit, Hôpital Lariboisière-AP-HP-GHU Nord and Diderot-Paris 7 University, 2 rue Ambroise Paré, 75475 Paris Cedex 10, France.
| | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Crohn’s disease: multi-detector row CT-enteroclysis appearance of the appendix. ACTA ACUST UNITED AC 2009; 35:654-60. [DOI: 10.1007/s00261-009-9575-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2009] [Revised: 06/02/2009] [Accepted: 08/31/2009] [Indexed: 12/22/2022]
|
42
|
Abstract
CT enterography has rapidly gained acceptance as a method for visualizing the small bowel lumen, wall and mesentery for a variety of clinical indications. Focusing on the identification of Crohn's disease, and vascular and neoplastic small bowel masses, this review summarizes oral contrast agents and CT acquisition techniques used for CT enterography, alternatives that can be used to tailor the exam for specific indications, and how such variations affect the appearance of a variety of pathologies at CT imaging.
Collapse
Affiliation(s)
- J G Fletcher
- Abdominal Imaging Feature Section, Radiology, Mayo Clinic, Rochester, MN 55905, USA.
| |
Collapse
|
43
|
Abstract
CT enterography (CTE) is a technique using neutral oral contrast, intravenous contrast and thin cut, multiplanar CT acquisitions to optimize small bowel imaging. One of the primary indications for CTE is the detection and evaluation of Crohn's disease. This article summarizes the advantages/disadvantages, scanning technique, imaging findings, performance and pitfalls of CTE for the evaluation of Crohn's disease.
Collapse
Affiliation(s)
- Amy K Hara
- Diagnostic Radiology, Mayo Clinic, Scottsdale, AZ 85259, USA.
| | | |
Collapse
|
44
|
Prospective comparison of state-of-the-art MR enterography and CT enterography in small-bowel Crohn's disease. AJR Am J Roentgenol 2009; 193:113-21. [PMID: 19542402 DOI: 10.2214/ajr.08.2027] [Citation(s) in RCA: 265] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE The objective of our study was to prospectively obtain pilot data on the accuracy of MR enterography for detecting small-bowel Crohn's disease compared with CT enterography and with a clinical reference standard based on imaging, clinical information, and ileocolonoscopy. SUBJECTS AND METHODS The study group for this blinded prospective study was composed of 33 patients with suspected active Crohn's ileal inflammation who were scheduled for clinical CT enterography and ileocolonoscopy and had consented to also undergo MR enterography. The MR enterography and CT enterography examinations were each interpreted by two radiologists with disagreements resolved by consensus. The reports from ileocolonoscopy with or without mucosal biopsy were interpreted by a gastroenterologist. The reference standard for the presence of small-bowel Crohn's disease was based on the final clinical diagnosis by the referring gastroenterologist after reviewing all of the available information. RESULTS All 33 patients underwent CT enterography and ileocolonoscopy, 30 of whom also underwent MR enterography. The sensitivities of MR enterography and CT enterography for detecting active small-bowel Crohn's disease were similar (90.5% vs 95.2%, respectively; p = 0.32). The image quality scores for MR enterography examinations were significantly lower than those for CT enterography (p = 0.005). MR enterography and CT enterography identified eight cases (24%) with a final diagnosis of active small-bowel inflammation in which the ileal mucosa appeared normal at ileocolonoscopy. Furthermore, enterography provided the only available imaging in three additional patients who did not have ileal intubation. CONCLUSION MR enterography and CT enterography have similar sensitivities for detecting active small-bowel inflammation, but image quality across the study cohort was better with CT. Cross-sectional enterography provides complementary information to ileocolonoscopy.
Collapse
|
45
|
Abdominopelvic extra-enteric findings at computed tomography enteroclysis: a retrospective evaluation of 430 consecutive patients. Clin Imaging 2009; 33:188-95. [PMID: 19411023 DOI: 10.1016/j.clinimag.2008.09.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2008] [Accepted: 09/09/2008] [Indexed: 12/21/2022]
Abstract
BACKGROUND Our objective was to retrospectively determine the frequency with which CT enteroclysis (CTE) shows abdominopelvic extra-enteric abnormalities and to analyze how such findings had actually and prospectively affected patient's care. METHODS The CTE examinations of 430 consecutive patients were retrospectively and blindly reviewed for the presence of possible pathologic conditions that might have affected abdominopelvic organs other than the small bowel. Extra-enteric abnormalities were categorized as negligible or important and correlated with patient's outcome and thus classified as having or not influenced patient's care. RESULTS Abdominopelvic extra-enteric abnormalities were present on CTE in 258 (60%) of 430 patients. Retrospective analysis of CTE images revealed negligible abnormalities in 217 patients (217/430, 50.5%) and important ones in 41 patients (41/430, 9.5%). Among the 41 patients with important abnormalities, CTE demonstrated already documented abnormalities in 22 patients (22/41, 53.7%) and unknown abnormalities in 19 patients (19/41, 46.3%). In the latter 19 patients, the detection of unknown abnormalities altered patient's care in 18 (94.7%) of them. In one patient (1/19, 5.3%), important abnormality was detected during retrospective evaluation but not prospectively, resulting in a delayed treatment, yielding missed important abnormality rate of 2.4% (1/41). CONCLUSIONS Abdominopelvic extra-enteric abnormalities are frequent on CTE, but their depictions rarely alter patient's care. However, in a few patients (19/430; 4.4%), CTE may reveal unknown extra-enteric abnormalities that require further evaluation and have substantial impact on patient's management.
Collapse
|
46
|
Multidetector helical CT in the evaluation of acute small bowel obstruction: Comparison of non-enhanced (no oral, rectal or IV contrast) and IV enhanced CT. Eur J Radiol 2009; 71:135-40. [DOI: 10.1016/j.ejrad.2008.04.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2007] [Revised: 02/29/2008] [Accepted: 04/02/2008] [Indexed: 01/29/2023]
|
47
|
Boriskin HS, Devito BS, Hines JJ, Scarmato VJ, Friedman B. CT enterography vs. capsule endoscopy. ACTA ACUST UNITED AC 2009; 34:149-55. [PMID: 18446400 DOI: 10.1007/s00261-008-9404-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Small bowel imaging has been revolutionized by CT enterography and capsule endoscopy. We present an overview of both imaging modalities, discuss advantages and disadvantages of each, and compare findings in Crohn's disease, occult gastrointestinal bleeding, and small bowel tumors. Both methods complement each other often providing information that the other one cannot.
Collapse
Affiliation(s)
- Howard S Boriskin
- Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, NY 11030, USA.
| | | | | | | | | |
Collapse
|
48
|
Abstract
CT enterography is a new imaging modality that has distinct advantages over conventional CT, wireless capsule endoscopy, and barium examination. CT enterography is noninvasive and allows rapid mapping of disease activity before endoscopy and in cases where the endoscope cannot reach the diseased segment. CT enterography is readily available, is operator independent, and allows evaluation of extraenteric complications of small bowel disease. This article describes the latest techniques and applications of CT enterography.
Collapse
|
49
|
Abstract
OBJECTIVE Acute mesenteric ischemia can be caused by various conditions such as arterial occlusion, venous occlusion, strangulating obstruction, and hypoperfusion associated with nonocclusive vascular disease, and the CT findings vary widely depending on the cause and underlying pathophysiology. The aim of this article is to review the CT appearances of acute mesenteric ischemia in various conditions. CONCLUSION Recognition of characteristic CT appearances and the variations associated with each cause may help in the accurate interpretation of CT in the diagnosis of mesenteric ischemia.
Collapse
|
50
|
Mural attenuation in normal small bowel and active inflammatory Crohn's disease on CT enterography: location, absolute attenuation, relative attenuation, and the effect of wall thickness. AJR Am J Roentgenol 2009; 192:417-23. [PMID: 19155404 DOI: 10.2214/ajr.08.1267] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE The purpose of our study was to measure relative and absolute wall attenuations and wall thickness in normal small bowel on contrast-enhanced CT enterography and to study the efficacy of relative attenuation, absolute attenuation, and wall thickness in distinguishing normal from active inflammatory Crohn's disease of the terminal ileum. MATERIALS AND METHODS Using a case-control study design, we reviewed 630 CT enterography examinations, of which 191 were normal and 36 had active inflammatory Crohn's disease in the terminal ileum. In healthy individuals, wall thickness and attenuation in distended and collapsed loops were measured in the duodenum and four abdominal quadrants. Wall thickness and attenuation were also measured in the terminal ileum. All measurements of intraarterial attenuation were taken at the same slice level. In the examinations of patients with Crohn's disease, only terminal ileum wall thickness and attenuation as well as arterial attenuation at the same slice level were measured. Normal segments were compared with a linear model. Terminal ileum data were fit to a multivariate logistic regression model. RESULTS Relative attenuation and absolute attenuation in the normal distended and collapsed duodenum and left upper quadrant were significantly greater than in all other segments (p < 0.001 and < 0.048 for relative attenuation and p < 0.001 and < 0.032 for absolute attenuation, respectively). Relative attenuation and wall thickness models and absolute attenuation and wall thickness models discriminated normal from active terminal ileum Crohn's disease significantly better than the same measurements without wall thickness (p = 0.017 and 0.001, respectively). When the bowel wall is > 3 mm, a relative attenuation cutoff of 0.5 is 89% sensitive and 81% specific. CONCLUSION In normal small bowel, when wall measurement is taken into account, the duodenum and jejunum have a greater relative attenuation and absolute attenuation than other segments. Relative attenuation and absolute attenuation with wall thickness models discriminate normal from active terminal ileum Crohn's disease better than the same measurements without wall thickness.
Collapse
|