1
|
Ream JM, Luk L, Sheedy S, Fletcher JG, Church JM, Baker ME. Dynamic ileal pouch emptying studies. Abdom Radiol (NY) 2023; 48:2956-2968. [PMID: 36732408 DOI: 10.1007/s00261-023-03811-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 02/04/2023]
Abstract
Although much radiologic literature has focused on the short-term post-operative complications associated with ileal pouches, as the number of patients with long-term pouches has grown, there is increasing realization of the functional deficits that may occur long after pouch creation. Dynamic pouch imaging using fluoroscopy and MRI can provide assessment of the underlying causes of symptomatic pouch dysfunction and can provide critical insight to the management of this complex patient population. In this paper, we provide an overview of the unique problems encountered in patients with long-term ileal pouches, and provide an overview of the techniques, interpretation, and reporting for fluoroscopic and MR pouch defecography.
Collapse
Affiliation(s)
- Justin M Ream
- Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.
| | - Lyndon Luk
- Department of Radiology, Columbia University Medical Center, New York, NY, USA
| | - Shannon Sheedy
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - J G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - James M Church
- Division of Colorectal Surgery, Columbia University Medical Center, New York, NY, USA
| | - Mark E Baker
- Imaging Institute, Digestive Diseases and Surgery Institute, and Cancer Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
2
|
Gordon IO, Bettenworth D, Bokemeyer A, Srivastava A, Rosty C, de Hertogh G, Robert ME, Valasek MA, Mao R, Kurada S, Harpaz N, Borralho P, Pai RK, Pai RK, Odze R, Feakins R, Parker CE, Nguyen T, Jairath V, Baker ME, Bruining DH, Fletcher JG, Feagan BG, Rieder F. Histopathology Scoring Systems of Stenosis Associated With Small Bowel Crohn's Disease: A Systematic Review. Gastroenterology 2020; 158:137-150.e1. [PMID: 31476299 PMCID: PMC7649049 DOI: 10.1053/j.gastro.2019.08.033] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/29/2019] [Accepted: 08/22/2019] [Indexed: 12/18/2022]
Abstract
BACKGROUND & AIMS Stenosis is a common complication of Crohn's disease (CD) that has no effective medical therapy. Development of antifibrotic agents will require testing in randomized controlled trials. Computed tomography enterography- and magnetic resonance enterography-based technologies might be used to measure outcomes in these trials. These approaches have been validated in studies of patients with symptomatic strictures who underwent imaging evaluations followed by resection with histopathologic grading of the intestinal tissue for inflammation and/or fibrosis (the reference standard). Imaging findings have correlated with findings from quantitative or semiquantitative histologic evaluation of the degree of fibromuscular stenosis and/or inflammation on the resection specimen. However, it is not clear whether histologic findings are an accurate reference standard. We performed a systematic review of all published histologic scoring systems used to assess stenosing CD. METHODS We performed a comprehensive search of Embase and MEDLINE of studies through March 13, 2019, that used a histologic scoring system to characterize small bowel CD and assessed inflammatory and fibrotic alterations within the same adult individual. All scores fitting the criteria were included in our analysis, independent of the presence of stricturing disease, as long as inflammation and fibrosis were evaluated separately but in the same scoring system. RESULTS We observed substantial heterogeneity among the scoring systems, which were not derived from modern principles for evaluative index development. None had undergone formal validity or reliability testing. None of the existing indices had been constructed according to accepted methods for the development of evaluative indices. Basic knowledge regarding their operating properties were lacking. Specific indices for evaluating the important pathologic component of myofibroblast hypertrophy or hyperplasia have not been proposed. CONCLUSIONS In a systematic review of publications, we found a lack of validated histopathologic scoring systems for assessment of fibromuscular stenosis. Data that describe the operating properties of existing cross-sectional imaging techniques for stenosing CD should be questioned. Development and validation of a histopathology index is an important research priority.
Collapse
Affiliation(s)
- Ilyssa O Gordon
- Department of Pathology, Robert J. Tomsich Pathology and Laboratory Medicine Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Dominik Bettenworth
- Department of Medicine B, Gastroenterology and Hepatology, University Hospital Münster, Münster, Germany
| | - Arne Bokemeyer
- Department of Medicine B, Gastroenterology and Hepatology, University Hospital Münster, Münster, Germany
| | - Amitabh Srivastava
- Department of Pathology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Christophe Rosty
- Department of Clinical Pathology, The University of Melbourne, Parville, Victoria, Australia; Envoi Specialist Pathologists, Brisbane, Queensland, Australia; Faculty of Medicine, University of Queensland, Brisbane, Queensland, Australia
| | - Gert de Hertogh
- Department of Pathology, University Hospital Leuven, Leuven, Belgium
| | - Marie E Robert
- Department of Pathology, Yale University School of Medicine, New Haven, Connecticut
| | - Mark A Valasek
- Department of Pathology, University of California San Diego, La Jolla, California
| | - Ren Mao
- Department of Gastroenterology, First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China; Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Satya Kurada
- Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, Ohio; Department of Gastroenterology, Hepatology and Nutrition, Digestive Diseases and Surgery Institute; Cleveland Clinic Foundation, Cleveland, Ohio
| | - Noam Harpaz
- Department of Pathology, Molecular and Cell-Based Medicine, Icahn School of Medicine at Mount Sinai, New York, New York
| | - Paula Borralho
- Faculdade de Medicina da Universidade de Lisboa, Instituto de Anatomia Patológica, Lisbon, Portugal
| | - Reetesh K Pai
- Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Rish K Pai
- Department of Laboratory Medicine and Pathology, Mayo Clinic Arizona, Scottsdale, Arizona
| | - Robert Odze
- Pathology Department, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Roger Feakins
- Department of Cellular Pathology, Royal London Hospital, Barts Health NHS Trust, London, United Kingdom
| | | | - Tran Nguyen
- Robarts Clinical Trials, Inc, London, Ontario, Canada
| | - Vipul Jairath
- Robarts Clinical Trials, Inc, London, Ontario, Canada; Department of Medicine, Western University, London, Ontario, Canada; Department of Biostatistics and Epidemiology, Western University, London, Ontario, Canada
| | - Mark E Baker
- Department of Diagnostic Radiology, Imaging Institute, Digestive Diseases and Surgery Institute, Cleveland, Ohio; Taussig Cancer Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - David H Bruining
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota
| | - J G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Brian G Feagan
- Robarts Clinical Trials, Inc, London, Ontario, Canada; Department of Medicine, Western University, London, Ontario, Canada; Department of Biostatistics and Epidemiology, Western University, London, Ontario, Canada
| | - Florian Rieder
- Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, Ohio; Department of Gastroenterology, Hepatology and Nutrition, Digestive Diseases and Surgery Institute; Cleveland Clinic Foundation, Cleveland, Ohio.
| |
Collapse
|
3
|
Fletcher JG, DeLone DR, Kotsenas AL, Campeau NG, Lehman VT, Yu L, Leng S, Holmes DR, Edwards PK, Johnson MP, Michalak GJ, Carter RE, McCollough CH. Evaluation of Lower-Dose Spiral Head CT for Detection of Intracranial Findings Causing Neurologic Deficits. AJNR Am J Neuroradiol 2019; 40:1855-1863. [PMID: 31649155 DOI: 10.3174/ajnr.a6251] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Accepted: 08/21/2019] [Indexed: 01/13/2023]
Abstract
BACKGROUND AND PURPOSE Despite the frequent use of unenhanced head CT for the detection of acute neurologic deficit, the radiation dose for this exam varies widely. Our aim was to evaluate the performance of lower-dose head CT for detection of intracranial findings resulting in acute neurologic deficit. MATERIALS AND METHODS Projection data from 83 patients undergoing unenhanced spiral head CT for suspected neurologic deficits were collected. Cases positive for infarction, intra-axial hemorrhage, mass, or extra-axial hemorrhage required confirmation by histopathology, surgery, progression of findings, or corresponding neurologic deficit; cases negative for these target diagnoses required negative assessments by two neuroradiologists and a clinical neurologist. A routine dose head CT was obtained using 250 effective mAs and iterative reconstruction. Lower-dose configurations were reconstructed (25-effective mAs iterative reconstruction, 50-effective mAs filtered back-projection and iterative reconstruction, 100-effective mAs filtered back-projection and iterative reconstruction, 200-effective mAs filtered back-projection). Three neuroradiologists circled findings, indicating diagnosis, confidence (0-100), and image quality. The difference between the jackknife alternative free-response receiver operating characteristic figure of merit at routine and lower-dose configurations was estimated. A lower 95% CI estimate of the difference greater than -0.10 indicated noninferiority. RESULTS Forty-two of 83 patients had 70 intracranial findings (29 infarcts, 25 masses, 10 extra- and 6 intra-axial hemorrhages) at routine head CT (CT dose index = 38.3 mGy). The routine-dose jackknife alternative free-response receiver operating characteristic figure of merit was 0.87 (95% CI, 0.81-0.93). Noninferiority was shown for 100-effective mAs iterative reconstruction (figure of merit difference, -0.04; 95% CI, -0.08 to 0.004) and 200-effective mAs filtered back-projection (-0.02; 95% CI, -0.06 to 0.02) but not for 100-effective mAs filtered back-projection (-0.06; 95% CI, -0.10 to -0.02) or lower-dose levels. Image quality was better at higher-dose levels and with iterative reconstruction (P < .05). CONCLUSIONS Observer performance for dose levels using 100-200 eff mAs was noninferior to that observed at 250 effective mAs with iterative reconstruction, with iterative reconstruction preserving noninferiority at a mean CT dose index of 15.2 mGy.
Collapse
Affiliation(s)
- J G Fletcher
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - D R DeLone
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - A L Kotsenas
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - N G Campeau
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - V T Lehman
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - L Yu
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - S Leng
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - D R Holmes
- Biomedical Imaging Resource (D.R.H., P.E.)
| | | | - M P Johnson
- Biomedical Statistics and Informatics (M.P.J.), Mayo Clinic, Rochester, Minnesota
| | - G J Michalak
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| | - R E Carter
- Health Sciences Research (R.E.C.), Mayo Clinic, Jacksonville, Florida
| | - C H McCollough
- From the Departments of Radiology (J.G.F., D.R.D., A.L.K., N.G.C., V.T.L., L.Y., S.L., G.J.M., C.H.M.)
| |
Collapse
|
4
|
Yu L, Hu Q, Koo CW, Takahashi EA, Levin DL, Johnson TF, Hora MJ, Dirks S, Chen B, McMillan K, Leng S, Fletcher JG, McCollough CH. A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT. Proc SPIE Int Soc Opt Eng 2017; 10132. [PMID: 28392614 DOI: 10.1117/12.2255593] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Task-based image quality assessment using model observers is promising to provide an efficient, quantitative, and objective approach to CT dose optimization. Before this approach can be reliably used in practice, its correlation with radiologist performance for the same clinical task needs to be established. Determining human observer performance for a well-defined clinical task, however, has always been a challenge due to the tremendous amount of efforts needed to collect a large number of positive cases. To overcome this challenge, we developed an accurate projection-based insertion technique. In this study, we present a virtual clinical trial using this tool and a low-dose simulation tool to determine radiologist performance on lung-nodule detection as a function of radiation dose, nodule type, nodule size, and reconstruction methods. The lesion insertion and low-dose simulation tools together were demonstrated to provide flexibility to generate realistically-appearing clinical cases under well-defined conditions. The reader performance data obtained in this virtual clinical trial can be used as the basis to develop model observers for lung nodule detection, as well as for dose and protocol optimization in lung cancer screening CT.
Collapse
Affiliation(s)
- Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Qiyuan Hu
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Chi Wan Koo
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | | | | - Megan J Hora
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Shane Dirks
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Baiyu Chen
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - J G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | |
Collapse
|
5
|
Montoya JC, Eckel LJ, DeLone DR, Kotsenas AL, Diehn FE, Yu L, Bartley AC, Carter RE, McCollough CH, Fletcher JG. Low-Dose CT for Craniosynostosis: Preserving Diagnostic Benefit with Substantial Radiation Dose Reduction. AJNR Am J Neuroradiol 2017; 38:672-677. [PMID: 28183836 DOI: 10.3174/ajnr.a5063] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 11/06/2016] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Given the positive impact of early intervention for craniosynostosis, CT is often performed for evaluation but radiation dosage remains a concern. We evaluated the potential for substantial radiation dose reduction in pediatric patients with suspected craniosynostosis. MATERIALS AND METHODS CT projection data from pediatric patients undergoing head CT for suspected craniosynostosis were archived. Simulated lower-dose CT images corresponding to 25%, 10%, and 2% of the applied dose were created using a validated method. Three neuroradiologists independently interpreted images in a blinded, randomized fashion. All sutures were evaluated by using 3D volume-rendered images alone, and subsequently with 2D and 3D images together. Reference standards were defined by reader agreement by using routine dose and 2D and 3D images. Performance figures of merit were calculated based on reader response and confidence. RESULTS Of 33 pediatric patients, 21 had craniosynostosis (39 positive sutures and 225 negative sutures). The mean volume CT dose index was 15.5 ± 2.3 mGy (range, 9.69-19.38 mGy) for the routine dose examination. Average figures of merit for multireader analysis ranged from 0.92 (95% CI, 0.90-0.95) at routine pediatric dose to 0.86 (95% CI, 0.79-0.94) at 2% dose using 3D images alone. Similarly, pooled reader figures of merit ranged from 0.91 (95% CI, 0.89-0.95) at routine pediatric dose to 0.85 (95% CI, 0.76-0.95) at 2% dose using 2D and 3D images together. At 25% and 10% dose, 95% CI of the difference in figures of merit from routine dose included 0, suggesting similar or noninferior performance. CONCLUSIONS For pediatric head CT for evaluation of craniosynostosis, dose reductions of 75%-90% were possible without compromising observer performance.
Collapse
Affiliation(s)
- J C Montoya
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - L J Eckel
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - D R DeLone
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - A L Kotsenas
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - F E Diehn
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - L Yu
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - A C Bartley
- Health Sciences Research (A.C.B., R.E.C.), Mayo Clinic, Rochester, Minnesota
| | - R E Carter
- Health Sciences Research (A.C.B., R.E.C.), Mayo Clinic, Rochester, Minnesota
| | - C H McCollough
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| | - J G Fletcher
- From the Departments of Radiology (J.C.M., L.J.E., D.R.D., A.L.K., F.E.D., L.Y., C.H.M., J.G.F.)
| |
Collapse
|
6
|
Kotsenas AL, Michalak GJ, DeLone DR, Diehn FE, Grant K, Halaweish AF, Krauss A, Raupach R, Schmidt B, McCollough CH, Fletcher JG. CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization? AJNR Am J Neuroradiol 2015; 36:2184-90. [PMID: 26251433 DOI: 10.3174/ajnr.a4416] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2015] [Accepted: 03/11/2015] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Metal-related artifacts from spine instrumentation can obscure relevant anatomy and pathology. We evaluated the ability of CT images reconstructed with and without iterative metal artifact reduction to visualize critical anatomic structures in postoperative spines and assessed the potential for implementation into clinical practice. MATERIALS AND METHODS We archived CT projection data in patients with instrumented spinal fusion. CT images were reconstructed by using weighted filtered back-projection and iterative metal artifact reduction. Two neuroradiologists evaluated images in the region of spinal hardware and assigned a score for the visualization of critical anatomic structures by using soft-tissue and bone windows (critical structures totally obscured, n = 0; anatomic recognition with high diagnostic confidence, n = 5). Using bone windows, we measured the length of the most pronounced linear artifacts. For each patient, neuroradiologists made recommendations regarding the optimal use of iterative metal artifact reduction and its impact on diagnostic confidence. RESULTS Sixty-eight patients met the inclusion criteria. Visualization of critical soft-tissue anatomic structures was significantly improved by using iterative metal artifact reduction compared with weighted filtered back-projection (median, 1 ± 1.5 versus 3 ± 1.3, P < .001), with improvement in the worst visualized anatomic structure in 88% (60/68) of patients. There was not significant improvement in visualization of critical osseous structures. Linear metal artifacts were reduced from 29 to 11 mm (P < .001). In 87% of patients, neuroradiologists recommended reconstructing iterative metal artifact reduction images instead of weighted filtered back-projection images, with definite improvement in diagnostic confidence in 32% (22/68). CONCLUSIONS Iterative metal artifact reduction improves visualization of critical soft-tissue structures in patients with spinal hardware. Routine generation of these images in addition to routine weighted filtered back-projection is recommended.
Collapse
Affiliation(s)
- A L Kotsenas
- From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota
| | - G J Michalak
- From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota
| | - D R DeLone
- From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota
| | - F E Diehn
- From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota
| | - K Grant
- Siemens Medical Solutions (K.G., A.F.H.), Malvern, Pennsylvania
| | - A F Halaweish
- Siemens Medical Solutions (K.G., A.F.H.), Malvern, Pennsylvania
| | - A Krauss
- Siemens Healthcare (A.K., R.R., B.S.), Forchheim, Germany
| | - R Raupach
- Siemens Healthcare (A.K., R.R., B.S.), Forchheim, Germany
| | - B Schmidt
- Siemens Healthcare (A.K., R.R., B.S.), Forchheim, Germany
| | - C H McCollough
- From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota
| | - J G Fletcher
- From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
7
|
Gabriel S, Eckel LJ, DeLone DR, Krecke KN, Luetmer PH, McCollough CH, Fletcher JG, Yu L. Pilot study of radiation dose reduction for pediatric head CT in evaluation of ventricular size. AJNR Am J Neuroradiol 2014; 35:2237-42. [PMID: 25082822 DOI: 10.3174/ajnr.a4056] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND AND PURPOSE CT is a ubiquitous, efficient, and cost-effective method to evaluate pediatric ventricular size, particularly in patients with CSF shunt diversion who often need emergent imaging. We therefore sought to determine the minimum dose output or CT dose index required to produce clinically acceptable examinations. MATERIALS AND METHODS Using a validated noise insertion method and CT projection data from 22 patients, standard pediatric head CT images were reconstructed with weighted filtered back-projection and sinogram-affirmed iterative reconstruction corresponding to routine, 25%, and 10% dose. Reconstructed images were then evaluated by 3 neuroradiologists (blinded to dose and reconstruction method) for ventricular size, diagnostic confidence, image quality, evidence of hemorrhage, and shunt tip location, and compared with the reference standard. RESULTS There was no significant difference in the ventricular size ranking, and the sensitivity for moderate to severe hydrocephalus was 100%. There was no significant difference between the full-dose level and the ventricular size rankings at the 25% or the 10% dose level for either reconstruction kernel (P > .979). Diagnostic confidence was maintained across doses and kernel. Hemorrhage was more difficult to identify as image quality degraded as dose decreased but was still seen in a majority of cases. Shunts were identified by all readers across all doses and reconstruction methods. CONCLUSIONS CT images having dose reductions of 90% relative to routine head CT examinations provide acceptable image quality to address the specific clinical task of evaluating ventricular size.
Collapse
Affiliation(s)
- S Gabriel
- From the Department of Radiology (S.G.), University of California Los Angeles, Los Angeles, California
| | - L J Eckel
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota.
| | - D R DeLone
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota
| | - K N Krecke
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota
| | - P H Luetmer
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota
| | - C H McCollough
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota
| | - J G Fletcher
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota
| | - L Yu
- Department of Radiology (L.J.E., D.R.D., K.N.K., P.H.L., C.H.M., J.G.F., L.Y.), Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
8
|
Glazebrook KN, Brewerton LJ, Leng S, Carter RE, Rhee PC, Murthy NS, Howe BM, Ringler MD, Dahm DL, Stuart MJ, McCollough CH, Fletcher JG. Case-control study to estimate the performance of dual-energy computed tomography for anterior cruciate ligament tears in patients with history of knee trauma. Skeletal Radiol 2014; 43:297-305. [PMID: 24337491 DOI: 10.1007/s00256-013-1784-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2013] [Revised: 11/06/2013] [Accepted: 11/10/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Computed tomography (CT) is used to assess for fracture after knee trauma, but identification of ligamentous injuries may also be beneficial. Our purpose is to assess the potential of dual-energy computed tomography (DECT) for the detection of complete anterior cruciate ligament (ACL) disruption. METHODS Sixteen patients with unilateral traumatic ACL disruption (average of 58 days following trauma) confirmed by MRI, and 11 control patients without trauma, underwent DECT of both knees. For each knee, axial, sagittal, and oblique sagittal images (with DECT bone removal, single-energy (SE) bone removal, and DECT tendon-specific color mapping) were reconstructed. Four musculoskeletal radiologists randomly evaluated the 324 DECT reconstructed series (54 knees with 6 displays) separately, to assess for ACL disruption using a five-point scale (1 = definitely not torn, to 5 = definitely torn). ROC analysis was used to compare performance across readers and displays. RESULTS Sagittal oblique displays (mixed kV soft tissue, SE bone removal, and DECT bone removal) demonstrated higher areas under the curve for ACL disruption (AUC = 0.95, 0.93 and 0.95 respectively) without significant differences in performance between readers (p > 0.23). Inter-reader agreement was also better for these display methods (ICC range 0.62-0.69) compared with other techniques (ICC range 0.41-0.57). Mean sensitivity for ACL disruption was worst for DECT tendon-specific color map and axial images (24 % and 63 % respectively). CONCLUSION DECT knee images with oblique sagittal reconstructions using either mixed kV or bone removal displays (either DECT or SE) depict ACL disruption in the subacute or chronic setting with reliable identification by musculoskeletal radiologists.
Collapse
Affiliation(s)
- Katrina N Glazebrook
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA,
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Abstract
CT enterography has rapidly gained acceptance as a method for visualizing the small bowel lumen, wall and mesentery for a variety of clinical indications. Focusing on the identification of Crohn's disease, and vascular and neoplastic small bowel masses, this review summarizes oral contrast agents and CT acquisition techniques used for CT enterography, alternatives that can be used to tailor the exam for specific indications, and how such variations affect the appearance of a variety of pathologies at CT imaging.
Collapse
Affiliation(s)
- J G Fletcher
- Abdominal Imaging Feature Section, Radiology, Mayo Clinic, Rochester, MN 55905, USA.
| |
Collapse
|
10
|
Abstract
CT enterography is a modification of conventional CT technique optimized for the evaluation of small bowel. This technique utilizes multidetector scanners with high spatial and temporal resolution; multiplanar reconstructions; and large volumes of enteric contrast to provide bowel distension. This article discusses the essential principles of the exam and its use in the evaluation of Crohn's disease of the small bowel.
Collapse
Affiliation(s)
- James E Huprich
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| | | |
Collapse
|
11
|
Siddiki H, Fletcher JG, McFarland B, Dajani N, Orme N, Koenig B, Strobel M, Wolf SM. Incidental findings in CT colonography: literature review and survey of current research practice. J Law Med Ethics 2008; 36:320-31, 213. [PMID: 18547201 PMCID: PMC2587005 DOI: 10.1111/j.1748-720x.2008.00276.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Incidental findings (IFs) of potential medical significance are seen in approximately 5-8 percent of asymptomatic subjects and 16 percent of symptomatic subjects participating in large computed tomography (CT) colonography (CTC) studies, with the incidence varying further by CT acquisition technique. While most CTC research programs have a well-defined plan to detect and disclose IFs, such plans are largely communicated only verbally. Written consent documents should also inform subjects of how IFs of potential medical significance will be detected and reported in CTC research studies.
Collapse
|
12
|
Affiliation(s)
- Adil E Bharucha
- Clinical Enteric Neuroscience Translational & Epidemiological Research Program, Division of Gastroenterology & Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA.
| | | |
Collapse
|
13
|
Fletcher JG, Booya F, Summers RM, Roy D, Guendel L, Schmidt B, McCollough CH, Fidler JL. Comparative performance of two polyp detection systems on CT colonography. AJR Am J Roentgenol 2007; 189:277-82. [PMID: 17646451 DOI: 10.2214/ajr.07.2289] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
OBJECTIVE The purpose of our study was to evaluate two current automatic polyp detection systems to determine their sensitivity and false-positive rate in patients who have undergone CT colonography and subsequent endoscopy. MATERIALS AND METHODS We evaluated two polyp detection systems--Polyp Enhanced Viewing (PEV) and the Summers computer-aided detection (CAD) system (National Institutes of Health [NIH]) using a unique cohort of CT colonography examinations: 31 examinations with true-positive lesions identified by radiologists and 34 examinations with false-positive lesions incorrectly identified by radiologists. All patients had reference-standard colonoscopy within 7 days of CT. Candidate lesions were compared with the endoscopic reference standard and prospective radiologist interpretation. The sensitivity and false-positive rates were calculated for each system. RESULTS The NIH system had a higher sensitivity than the PEV tool for polyps > or = 1 cm (22/23, 96%; 78-99%, 95% CI vs 14/23, 61%; 38-81%, 95% CI; p = 0.008, respectively). There was no significant difference in the detection of medium-sized polyps 6-9 mm in size (8/13 vs 6/13, p = 0.68, respectively). The PEV tool had an average of 1.18 false-positive detections per patient, whereas the NIH tool had an average of 5.20 false-positive detections per patient, with the PEV tool having significantly fewer false-positive detections in both patient groups (p < 0.001). CONCLUSION One polyp detection system tended to operate with a higher sensitivity, whereas the other tended to operate with a lower false-positive rate. Prospective trials using polyp detection systems as a primary or secondary means of CT colonography interpretation appear warranted.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Dzyubak OP, Primak AN, Takahashi N, Vrtiska TJ, Hartman RP, Kawashima A, Fletcher JG, Yu L, McCollough CH. TU-D-L100J-07: The Use of CT Dual-Energy Subtraction Imaging to Detect Kidney Stones Amid Iodinated Contrast Material. Med Phys 2007. [DOI: 10.1118/1.2761371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
15
|
Young BM, Fletcher JG, Paulsen SR, Booya F, Johnson CD, Johnson KT, Melton Z, Rodysill D, Mandrekar J. Polyp Measurement with CT Colonography: Multiple-Reader, Multiple-Workstation Comparison. AJR Am J Roentgenol 2007; 188:122-9. [PMID: 17179354 DOI: 10.2214/ajr.05.1535] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
OBJECTIVE The risk of invasive colorectal cancer in colorectal polyps correlates with lesion size. Our purpose was to define the most accurate methods for measuring polyp size at CT colonography (CTC) using three models of workstations and multiple observers. MATERIALS AND METHODS Six reviewers measured 24 unique polyps of known size (5, 7, 10, and 12 mm), shape (sessile, flat, and pedunculated), and location (straight or curved bowel segment) using CTC data sets obtained at two doses (5 mAs and 65 mAs) and a previously described colonic phantom model. Reviewers measured the largest diameter of polyps on three proprietary workstations. Each polyp was measured with lung and soft-tissue windows on axial, 2D multiplanar reconstruction (MPR), and 3D images. RESULTS There were significant differences among measurements obtained at various settings within each workstation (p < 0.0001). Measurements on 2D images were more accurate with lung window than with soft-tissue window settings (p < 0.0001). For the 65-mAs data set, the most accurate measurements were obtained in analysis of axial images with lung window, 2D MPR images with lung window, and 3D tissue cube images for Wizard, Advantage, and Vitrea workstations, respectively, without significant differences in accuracy among techniques (0.11 < p < 0.59). The mean absolute error values for these optimal settings were 0.48 mm, 0.61 mm, and 0.76 mm, respectively, for the three workstations. Within the ultralow-dose 5-mAs data set the best methods for Wizard, Advantage, and Vitrea were axial with lung window, 2D MPR with lung window, and 2D MPR with lung window, respectively. Use of nearly all measurement methods, except for the Vitrea 3D tissue cube and the Wizard 2D MPR with lung window, resulted in undermeasurement of the true size of the polyps. CONCLUSION Use of CTC computer workstations facilitates accurate polyp measurement. For routine CTC examinations, polyps should be measured with lung window settings on 2D axial or MPR images (Wizard and Advantage) or 3D images (Vitrea). When these optimal methods are used, these three commercial workstations do not differ significantly in acquisition of accurate polyp measurements at routine dose settings.
Collapse
Affiliation(s)
- Brett M Young
- Mayo Clinic College of Medicine, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
|
17
|
Colombel JF, Solem CA, Sandborn WJ, Booya F, Loftus EV, Harmsen WS, Zinsmeister AR, Bodily KD, Fletcher JG. Quantitative measurement and visual assessment of ileal Crohn's disease activity by computed tomography enterography: correlation with endoscopic severity and C reactive protein. Gut 2006; 55:1561-7. [PMID: 16648154 PMCID: PMC1860143 DOI: 10.1136/gut.2005.084301] [Citation(s) in RCA: 164] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Few studies have correlated computed tomography (CT) enterography findings with endoscopic severity and C reactive protein (CRP) concentrations. AIM To examine whether small bowel inflammation at CT enterography correlates with endoscopic severity and CRP in patients with Crohn's disease (CD). METHODS CT enterography datasets from 143 CD patients undergoing ileoscopy were examined for three different CT parameters: CT bowel enhancement, as defined by the ratio of terminal ileal versus control ileal loop attenuation; vascular enlargement of the vasa recta ("the comb sign"); and mesenteric fat density. Correlations between CT scan parameters, endoscopy, and histology severity scores, and CRP were assessed using Spearman's rank correlation and logistic regression. RESULTS Endoscopic score was significantly correlated with CT bowel enhancement, comb sign, and fat density (Spearman correlation coefficients 0.33-0.39; p<0.001). Correlations with histological inflammation were strongest for bowel enhancement (r = 0.34-0.38; p<0.001). CRP was elevated in patients with increased fat density versus those with increased bowel enhancement only (median 0.96 v 0.23, p = 0.002). CRP did not differ significantly between patients without evidence of active Crohn's and those with bowel enhancement and endoscopic inflammation not involving the perienteric tissues by CT (median 0.24 v 0.36; p = 0.38). CONCLUSION Quantitative measures of bowel enhancement at CT enterography correlate with endoscopic and histological severity. CRP correlates with radiological findings of perienteric inflammation (increased fat density), but not of inflammation limited to the small bowel wall, underscoring the potential role of perienteric inflammation in CRP response in CD.
Collapse
Affiliation(s)
- J F Colombel
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Lowe VJ, Booya F, Fletcher JG, Nathan M, Jensen E, Mullan B, Rohren E, Wiersema MJ, Vazquez-Sequeiros E, Murray JA, Allen MS, Levy MJ, Clain JE. Comparison of positron emission tomography, computed tomography, and endoscopic ultrasound in the initial staging of patients with esophageal cancer. Mol Imaging Biol 2006; 7:422-30. [PMID: 16270235 DOI: 10.1007/s11307-005-0017-0] [Citation(s) in RCA: 126] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Improvement in esophageal cancer staging is needed. Positron emission tomography (PET), computed tomography (CT), and endoscopic ultrasound (EUS) in the staging of esophageal carcinoma were compared. METHODS PET, CT, and EUS were performed and interpreted prospectively in 75 patients with newly diagnosed esophageal cancer. Either tissue confirmation or fine needle aspiration (FNA) was used as the gold standard of disease. Sensitivity and specificity for tumor, nodal, and metastatic (TNM) disease for each test were determined. TNM categorizations from each test were used to assign patients to subgroups corresponding to the three treatment plans that patients could theoretically receive, and these were then compared. RESULTS Local tumor staging (T) was done correctly by CT and PET in 42% and by EUS in 71% of patients (P value > 0.14). The sensitivity and specificity for nodal involvement (N) by modality were 84% and 67% for CT, 86% and 67% for EUS, and 82% and 60% for PET (P value > 0.38). The sensitivity and specificity for distant metastasis were 81% and 82% for CT, 73% and 86% for EUS, and 81% and 91% for PET (P value > 0.25). Treatment assignment was done correctly by CT in 65%, by EUS in 75%, and by PET in 70% of patients (P value > 0.34). CONCLUSIONS EUS had superior T staging ability over PET and CT in our study group. The tests showed similar performance in nodal staging and there was a trend toward improved distant disease staging with CT or PET over EUS. Assignment to treatment groups in relation to TNM staging tended to be better by EUS. Each test contributed unique patient staging information on an individual basis.
Collapse
Affiliation(s)
- Val J Lowe
- Department of Radiology, Mayo Clinic Rochester, 200 First Street SW, Rochester, MN 55905, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Abstract
OBJECTIVE To compare the prevalence of pelvic organ prolapse in subjects with defecatory disorders with that in control subjects. METHODS In 55 subjects with fecal incontinence, 42 subjects with obstructed defecation, and 45 healthy subjects without defecatory symptoms, a urogynecologist assessed pelvic organ prolapse by the pelvic organ prolapse quantification system, and a gastroenterologist evaluated perineal descent during simulated evacuation. A multiple logistic regression model evaluated whether obstetric-gynecological variables, including pelvic organ prolapse, could discriminate among controls, subjects with fecal incontinence, and subjects with obstructed defecation. RESULTS Fifty-five percent of controls, 42% of those with obstructed defecation, and 29% of those with fecal incontinence had stage II or greater prolapse by clinical examination. Eleven percent of controls, 7% of those with obstructed defecation, and 47% of subjects with fecal incontinence had a forceps delivery. Eighteen percent of controls, 31% of those with obstructed defecation, and 64% of those with fecal incontinence had a hysterectomy. Even after controlling for a higher prevalence of obstetric risk factors and hysterectomy, fecal incontinence was associated with a lower risk of stage II or greater pelvic organ prolapse (odds ratio for fecal incontinence in > or = stage II pelvic organ prolapse relative to stage 0 pelvic organ prolapse = 0.1, 95% confidence interval 0.01-0.53). In contrast, pelvic organ prolapse severity was not associated with control versus obstructed defecation status. Seven percent of controls, 18% of subjects with obstructed defecation, and 7% of those with fecal incontinence had increased perineal descent during simulated evacuation. Excessive perineal descent was associated (P < .01) with pelvic organ prolapse. CONCLUSION Despite a higher prevalence of risk factors for pelvic floor injury, pelvic organ prolapse severity was lower in those with fecal incontinence than in subjects without bowel symptoms. However, a subset of subjects with defecatory disorders, predominantly obstructed defecation, have excessive perineal descent, which is associated with pelvic organ prolapse.
Collapse
Affiliation(s)
- Christopher J Klingele
- Department of Obstetrics and Gynecology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905, USA
| | | | | | | | | | | |
Collapse
|
20
|
Bharucha AE, Fletcher JG, Harper CM, Hough D, Daube JR, Stevens C, Seide B, Riederer SJ, Zinsmeister AR. Relationship between symptoms and disordered continence mechanisms in women with idiopathic faecal incontinence. Gut 2005; 54:546-55. [PMID: 15753542 PMCID: PMC1774446 DOI: 10.1136/gut.2004.047696] [Citation(s) in RCA: 175] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND AND AIMS Anal sphincter weakness and rectal sensory disturbances contribute to faecal incontinence (FI). Our aims were to investigate the relationship between symptoms, risk factors, and disordered anorectal and pelvic floor functions in FI. METHODS In 52 women with "idiopathic" FI and 21 age matched asymptomatic women, we assessed symptoms by standardised questionnaire, anal pressures by manometry, anal sphincter appearance by endoanal ultrasound and magnetic resonance imaging (MRI), pelvic floor motion by dynamic MRI, and rectal compliance and sensation by a barostat. RESULTS The prevalence of anal sphincter injury (by imaging), reduced anal resting pressure (35% of FI), and reduced squeeze pressures (73% of FI) was higher in FI compared with controls. Puborectalis atrophy (by MRI) was associated (p<0.05) with FI and with impaired anorectal motion during pelvic floor contraction. Volume and pressure thresholds for the desire to defecate were lower, indicating rectal hypersensitivity, in FI. The rectal volume at maximum tolerated pressure (that is, rectal capacity) was reduced in 25% of FI; this volume was associated with the symptom of urge FI (p<0.01) and rectal hypersensitivity (p = 0.02). A combination of predictors (age, body mass index, symptoms, obstetric history, and anal sphincter appearance) explained a substantial proportion of the interindividual variation in anal squeeze pressure (45%) and rectal capacity (35%). CONCLUSIONS Idiopathic FI in women is a multifactorial disorder resulting from one or more of the following: a disordered pelvic barrier (anal sphincters and puborectalis), or rectal capacity or sensation.
Collapse
Affiliation(s)
- A E Bharucha
- Clinical Enteric Neuroscience Translational and Epidemiological Research Program (CENTER), Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Fletcher JG, Booya F, Johnson CD, Ahlquist D. CT colonography: unraveling the twists and turns. Curr Opin Gastroenterol 2005; 21:90-8. [PMID: 15687891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
PURPOSE OF REVIEW The performance of CT colonography has varied widely among published studies to date. This paper reviews differences in indications, populations, technique, and radiologist visualization, to elucidate the key factors that may give rise to disparate results. RECENT FINDINGS The role of CT colonography in screening asymptomatic patients is controversial. Studies employing subjects with known neoplasms generally report higher accuracy, while studies employing surveillance subjects report lower accuracy. Technical factors that appear to be associated with higher accuracy include meticulous bowel preparation and inflation, multidetector CT, combined two- and three-dimensional visualization, and radiologist experience and proclivity. Interobserver variability and practice guidelines remain significant issues for this developing technique. Interobserver variability may be reduced in the future by computer-aided detection algorithms or the routine use of skilled second readers. CT colonography is performed routinely for some indications, as it has demonstrated superior performance to noncolonoscopic screening alternatives. SUMMARY The disparity in results of reported large-scale CT colonography studies in asymptomatic subjects may be explained in part by differences in patient population characteristics, CT technique, and interobserver variability. CT colonography exceeds the performance of nonendoscopic approaches to colorectal cancer screening. Continuing innovation will seek to improve endoluminal visualization, reduce interobserver variability, and improve patient acceptance.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, New York 55905, USA.
| | | | | | | |
Collapse
|
22
|
Christensen JA, Fletcher JG, Fidler JL, Wold PB, Binstock AJ, Smyrk T, Harmsen SW, Crownhart BS, Chari S. Intraductal Papillary Mucinous Neoplasms of the Pancreas: CT Patterns of Recurrence and Multiobserver Performance in Detecting Recurrent Neoplasm After Surgical Resection. AJR Am J Roentgenol 2004; 183:1367-74. [PMID: 15505305 DOI: 10.2214/ajr.183.5.1831367] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE The purposes of our study were to describe the CT appearance of recurrent intraductal papillary mucinous neoplasms of the pancreas after surgical resection and estimate the performance of CT in detecting recurrent neoplasms. MATERIALS AND METHODS A single unblinded reviewer characterized the presence and appearance of recurrent intraductal papillary mucinous neoplasms on 66 CT scans of 17 patients with proven recurrence, noting location and appearance of recurrent neoplasm. These results, described in this article, were summarized in tabular format and shown to three blinded observer. The observers then evaluated one postoperative CT examination from every patient at our institution who underwent surgical removal of intraductal papillary mucinous neoplasms (n = 45) for the presence or absence of local or distant recurrence. RESULTS The unblinded reviewer found 11 cases of local recurrence. Extrapancreatic local recurrences tend to have solid components (5/6), tend to be located adjacent to the resection margin (5/6), and may exhibit vascular invasion (2/6). Intrapancreatic neoplasms are usually cystic (4/5). Nine patients had distant metastases. Prospective sensitivity for recurrent tumor ranged from 76% (13/17) to 94% (16/17). Sensitivity for local recurrence ranged from 55% (6/11) to 82% (9/11). Specificity ranged from 79% (22/28) to 96% (27/28). Interobserver agreement for predicting recurrence was moderate to substantial (kappa = 0.51-0.65). CONCLUSION Locally recurrent intraductal papillary mucinous neoplasms of the pancreas tend to be either extrapancreatic and solid at the resection margin or intrapancreatic and cystic. CT can detect most recurrent intraductal papillary mucinous neoplasms of the pancreas with moderate to substantial interobserver agreement.
Collapse
MESH Headings
- Adenocarcinoma, Mucinous/diagnostic imaging
- Adenocarcinoma, Mucinous/secondary
- Adenocarcinoma, Mucinous/surgery
- Aged
- Aged, 80 and over
- Carcinoma, Pancreatic Ductal/diagnostic imaging
- Carcinoma, Pancreatic Ductal/pathology
- Carcinoma, Pancreatic Ductal/surgery
- Carcinoma, Papillary/diagnostic imaging
- Carcinoma, Papillary/secondary
- Carcinoma, Papillary/surgery
- Female
- Humans
- Male
- Middle Aged
- Neoplasm Recurrence, Local/diagnostic imaging
- Pancreatic Neoplasms/diagnostic imaging
- Pancreatic Neoplasms/pathology
- Pancreatic Neoplasms/surgery
- Sensitivity and Specificity
- Tomography, X-Ray Computed
Collapse
Affiliation(s)
- Jared A Christensen
- Mayo Medical School, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Gluecker TM, Fletcher JG, Welch TJ, MacCarty RL, Harmsen WS, Harrington JR, Ilstrup D, Wilson LA, Corcoran KE, Johnson CD. Characterization of lesions missed on interpretation of CT colonography using a 2D search method. AJR Am J Roentgenol 2004; 182:881-9. [PMID: 15039159 DOI: 10.2214/ajr.182.4.1820881] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE We examined potential factors that may cause false-negative results on CT colonography examinations. MATERIALS AND METHODS In this prospective and retrospective study, 500 asymptomatic patients at high risk for colorectal cancer underwent CT colonography and colonoscopy. Each CT data set was interpreted by two independent observers, who were unaware of endoscopic findings, using a method of searching through enlarged axial images to detect intraluminal lesions. Another observer identified and characterized lesions missed at prospective interpretation. Polyps were assessed for size, method of visualization, intrinsic and extrinsic features, and examination quality. RESULTS We found 116 polyps at least 5 mm in diameter, 54 (47%) of which were missed by at least one of the prospective observers. Polyps seen in only one position were missed more often than polyps seen in both supine and prone positions (84% vs 50%, p < 0.01). Polyps located in suboptimally prepared colonic segments or along a thickened colonic wall were more frequently missed (p = 0.02 and p = 0.05, respectively). Endoscopic morphology and irregular surface contour were associated with missed lesions of all sizes (p = 0.03 and p = 0.04, respectively). Rounded intraluminal lesions were detected more often than other morphologies on CT (p = 0.04). CONCLUSION Factors that influence the likelihood that a polyp may be missed at interpretation of CT colonography include being seen only in one position, having flat endoscopic or CT morphology, having surface irregularity, and being located in a poorly prepared segment or along a thickened colonic wall. Understanding these features should lead to improved polyp detection on CT colonography.
Collapse
Affiliation(s)
- Thomas M Gluecker
- Department of Radiology, Mayo Clinic Rochester, 200 First St. SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Gangi S, Fletcher JG, Nathan MA, Christensen JA, Harmsen WS, Crownhart BS, Chari ST. Time interval between abnormalities seen on CT and the clinical diagnosis of pancreatic cancer: retrospective review of CT scans obtained before diagnosis. AJR Am J Roentgenol 2004; 182:897-903. [PMID: 15039161 DOI: 10.2214/ajr.182.4.1820897] [Citation(s) in RCA: 164] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE Our purpose was to determine whether abdominal CT can detect pancreatic cancer before its clinical diagnosis. SUBJECTS AND METHODS Two radiologists interpreted in a blinded manner 62 CT scans in 28 pancreatic cancer patients that were obtained before histologic diagnosis and 89 CT scans in 89 control subjects and noted specific CT findings. The presence of pancreatic cancer was characterized as definite, suspicious, low probability, or normal. The scans of the pancreatic cancer patients were divided into four groups on the basis of the time interval preceding cancer diagnosis (0-2, 2-6, 6-18, or > 18 months), and one scan (closest to 18 months) was selected per patient per time interval. Sensitivity and specificity for pancreatic cancer and interobserver agreement for CT findings were calculated. RESULTS Radiologists agreed that CT findings definite or suspicious for pancreatic cancer were present in 50% of the scans obtained 2-6 and 6-18 months before the diagnosis of pancreatic cancer (3/6 and 4/8 scans, respectively), but they noted such CT findings in only 7% (1/15) of the scans obtained more than 18 months before diagnosis. Pancreatic duct dilatation and cutoff were early CT findings identified by both radiologists and were associated with near-perfect and substantial interobserver agreement (kappa = 0.84 and 0.76, respectively). Ninety-five percent confidence intervals of specificity for tumor absence ranged from 92% to 100%. CONCLUSION CT can detect a significant proportion of asymptomatic incident pancreatic cancers before the clinical diagnosis of pancreatic cancer. CT should be considered in screening at-risk patient populations. Pancreatic duct dilatation and cutoff are early findings associated with the development of pancreatic cancer and can be detected on CT with a high degree of reproducibility.
Collapse
Affiliation(s)
- Sumana Gangi
- University of Medicine and Dentistry of New Jersey, Newark, NJ, USA
| | | | | | | | | | | | | |
Collapse
|
25
|
Fidler JL, Fletcher JG, Reading CC, Andrews JC, Thompson GB, Grant CS, Service FJ. Preoperative detection of pancreatic insulinomas on multiphasic helical CT. AJR Am J Roentgenol 2003; 181:775-80. [PMID: 12933480 DOI: 10.2214/ajr.181.3.1810775] [Citation(s) in RCA: 140] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective was to analyze enhancement characteristics of insulinomas and to determine the ability of multiphase CT to localize these tumors. MATERIALS AND METHODS Prospective interpretations of multiphase helical CT scans were reviewed in 30 patients who had insulinomas resected over a 5-year period. CT scans were retrospectively reviewed to determine enhancement characteristics, tumor conspicuity in each phase of enhancement, and potential causes for false-negative findings. RESULTS Sixty-three percent (19/30) of tumors were identified on CT prospectively. An additional six tumors were visualized in retrospect, allowing characterization of 25 (83%) of 30 tumors. Most tumors were hyperdense on at least one phase (n = 19), three tumors were hypoattenuating, and three were isodense and pedunculated. Insulinomas were most conspicuous on the early phase in 15 patients and in the portal venous phase in three. All tumors that underwent pancreatic phase imaging were seen (13/13), whereas three of 18 arterial and six of 25 portal venous phase findings were inconclusive for tumor. In the six examinations with false-negative findings in which the tumor could be seen in retrospect, two tumors were isodense and pedunculated, three were in close proximity to vessels, and one had a cystic appearance. CONCLUSION Multiphasic CT has a moderate sensitivity in the detection of insulinomas. Most tumors are more conspicuous on the earlier phases of enhancement. The pancreatic phase may be more useful than the arterial phase. Potential sources of false-negative results include tumors adjacent to vessels, pedunculated morphology, or nonhyperattenuating lesions.
Collapse
Affiliation(s)
- J L Fidler
- Department of Radiology, Mayo Clinic and Mayo Foundation, 200 First St. S.W., Rochester, MN 55905, USA.
| | | | | | | | | | | | | |
Collapse
|
26
|
Fletcher JG, Busse RF, Riederer SJ, Hough D, Gluecker T, Harper CM, Bharucha AE. Magnetic resonance imaging of anatomic and dynamic defects of the pelvic floor in defecatory disorders. Am J Gastroenterol 2003; 98:399-411. [PMID: 12591061 DOI: 10.1111/j.1572-0241.2003.07235.x] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Endoanal ultrasound identifies anal sphincter anatomy, and evacuation proctography visualizes pelvic floor motion during simulated defecation. These complementary techniques can evaluate obstructed defecation and fecal incontinence. Our aim was to develop a single, nonionizing, minimally invasive modality to image global pelvic floor anatomy and motion. METHODS We studied six patients with fecal incontinence and seven patients with obstructed defecation. The anal sphincters were imaged with an endoanal magnetic resonance imaging (MRI) coil and endoanal ultrasound (five patients). MR fluoroscopy acquired images every 1.4-2 s, using a modified real-time, T2-weighted, single-shot, fast-spin echo sequence, recording motion as patients squeezed pelvic floor muscles and expelled ultrasound gel; no contrast was added to other pelvic organs. Six patients also had scintigraphic defecography. RESULTS Endoanal ultrasound and MRI were comparable for imaging defects of the internal and external sphincters. Only MRI revealed puborectalis and/or external sphincter atrophy; four of these patients had fecal incontinence. MR fluoroscopy recorded pelvic floor contraction during squeeze and recorded relaxation during simulated defecation. Corresponding comparisons for angle change and perineal descent during defecation were not significant; only MRI, but not scintigraphy, identified excessive perineal descent in two patients. CONCLUSIONS Pelvic MRI is a promising single, comprehensive, nonradioactive modality to measure structural and functional pelvic floor disturbances in defecatory disorders. This method may provide insights into mechanisms of normal and disordered pelvic floor function in health and disease.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic and Mayo Medical School, Rochester, Minnesota 55905, USA
| | | | | | | | | | | | | |
Collapse
|
27
|
Gluecker TM, Fletcher JG. CT colonography (virtual colonoscopy) for the detection of colorectal polyps and neoplasms. current status and future developments. Eur J Cancer 2002; 38:2070-8. [PMID: 12387832 DOI: 10.1016/s0959-8049(02)00384-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Computed tomography colonography (CTC) is a new, rapidly developing non-invasive CT technique used to detect colonic polyps and cancers. It employs two- (2D) and three-dimensional (3D) images of the colon in order to display neoplastic lesions. Clinical trials demonstrate promising results for the detection of polyps and cancers greater than or equal to 10 mm in size. Our purpose is to describe the technique of CT colonography, review recent published trials of CT colonography, and elucidate current clinical applications. Continuing technical innovations such as multidetector CT, computer-aided diagnosis, new image display techniques and faecal tagging promise to improve the performance and patient acceptance of CT colonography in the future.
Collapse
Affiliation(s)
- T M Gluecker
- Department of Radiology, Mayo Clinic Rochester, 200 First Street S.W. Rochester, MN 55905, USA
| | | |
Collapse
|
28
|
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic and Mayo Foundation, 200 First Street SW, Rochester, MN 55905, USA
| |
Collapse
|
29
|
Fletcher JG, Johnson CD, Krueger WR, Ahlquist DA, Nelson H, Ilstrup D, Harmsen WS, Corcoran KE. Contrast-enhanced CT colonography in recurrent colorectal carcinoma: feasibility of simultaneous evaluation for metastatic disease, local recurrence, and metachronous neoplasia in colorectal carcinoma. AJR Am J Roentgenol 2002; 178:283-90. [PMID: 11804881 DOI: 10.2214/ajr.178.2.1780283] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Contrast-enhanced CT colonography has the potential to detect local recurrence, metachronous disease, and distant metastases in patients with a history of invasive colorectal cancer. The purpose of our study was to determine whether colonic anastomoses prohibit adequate colonic distention on contrast-enhanced CT colonography and to estimate the performance of contrast-enhanced CT colonography in detecting recurrent colorectal carcinoma. MATERIALS AND METHODS Fifty patients with a history of resected invasive colorectal carcinoma underwent contrast-enhanced CT colonography and colonoscopy. Colonic distention was graded for different colonic segments. Two radiologists evaluated for the presence of local recurrence, metachronous disease, and metastatic disease. Results were compared with colonoscopy, histology, and clinical follow-up. RESULTS Most patients had adequate colonic inflation (37/50, 74%). Eleven of 13 patients with inadequate distention had collapse in the sigmoid colon, usually associated with ileocolic anastomoses. Contrast-enhanced CT colonography detected local recurrences with an accuracy of 94% (95% confidence interval, 83-99%). The accuracy of contrast-enhanced CT colonography for metachronous lesions greater than or equal to 1 cm was 92% (95% confidence interval, 80-98%), but there was only one such lesion, which was missed on initial colonoscopy. Stool, granulation tissue, and inflammation can mimic the CT appearance of local recurrence or metachronous disease and account for false-positive examinations. Contrast-enhanced CT colonography identified five patients with metastatic disease. CONCLUSION Suboptimal sigmoid distention can be seen on contrast-enhanced CT colonography, predominantly in patients with right hemicolectomies. Contrast-enhanced CT colonography is a promising method for detecting local recurrence, metachronous disease, and distant metastases in patients with prior invasive colorectal carcinoma. The technique can also serve as a useful adjunct to colonoscopy by detecting local recurrences or metachronous disease that are endoscopically obscure or by serving as a full structural colonic examination when endoscopy is incomplete.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic, East-2B, 200 First St., S.W., Rochester, MN 55905, USA
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
Planar virtual pathology (PVP) is an isometric rendering method for examining the CT colonography dataset, which renders the colon in discrete colonic segments. Ten patients with 36 polyps were evaluated using traditional 2D axial, 2D multiplanar reformatted, and 3D endoluminal images as well as PVP. PVP displayed 13 of 17 (76%) polyps of >1 cm, whereas 11 of 17 (65%) were detected using traditional rendering methods. PVP may be a useful adjunct in detecting additional polyps at CT colonography.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
| | | | | | | |
Collapse
|
31
|
Schwartz DA, Wiersema MJ, Dudiak KM, Fletcher JG, Clain JE, Tremaine WJ, Zinsmeister AR, Norton ID, Boardman LA, Devine RM, Wolff BG, Young-Fadok TM, Diehl NN, Pemberton JH, Sandborn WJ. A comparison of endoscopic ultrasound, magnetic resonance imaging, and exam under anesthesia for evaluation of Crohn's perianal fistulas. Gastroenterology 2001; 121:1064-72. [PMID: 11677197 DOI: 10.1053/gast.2001.28676] [Citation(s) in RCA: 323] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND & AIMS To determine accuracy of endoscopic ultrasound (EUS) and magnetic resonance imaging (MRI) for evaluation of Crohn's disease perianal fistulas. METHODS Thirty-four patients with suspected Crohn's disease perianal fistulas were prospectively enrolled in a blinded study comparing EUS, MRI, and examination under anesthesia (EUA). Fistulas were classified according to Parks' criteria, and a consensus gold standard was determined for each patient. Acceptable accuracy was defined as agreement with the consensus gold standard for > or =85% of patients. RESULTS Three patients did not undergo MRI; 1 did not undergo EUS or EUA; and consensus could not be reached for 1. Thirty-two patients had 39 fistulas (20 trans-sphincteric, 5 extra-sphincteric, 6 recto-vaginal, 8 others) and 13 abscesses. The accuracy of all 3 modalities was > or =85%: EUS 29 of 32 (91%, confidence interval [CI] 75%-98%), MRI 26 of 30 (87%, CI 69%-96%), and EUA 29 of 32 (91%, CI 75%-98%). Accuracy was 100% when any 2 tests were combined. CONCLUSIONS EUS, MRI, and EUA are accurate tests for determining fistula anatomy in patients with perianal Crohn's disease. The optimal approach may be combining any 2 of the 3 methods.
Collapse
Affiliation(s)
- D A Schwartz
- The Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota 55905, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Callstrom MR, Johnson CD, Fletcher JG, Reed JE, Ahlquist DA, Harmsen WS, Tait K, Wilson LA, Corcoran KE. CT colonography without cathartic preparation: feasibility study. Radiology 2001; 219:693-8. [PMID: 11376256 DOI: 10.1148/radiology.219.3.r01jn22693] [Citation(s) in RCA: 203] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate methods for contrast material labeling of stool in the unprepared colon for computed tomographic (CT) colonography and to determine their sensitivity for polyp detection. MATERIALS AND METHODS Fifty-six patients with suspected or known polyps were assigned to five groups. Two to seven doses of 225 mL of dilute contrast material were orally administered during 24 or 48 hours. Transverse CT images were assessed for effectiveness of stool labeling. Colonoscopy was performed in all patients and was the standard. Two radiologists blinded to prior imaging and colonoscopic results assessed polyp detection. RESULTS For each group, average stool labeling scores and ranges were as follows: 24 hour two dose, 16% and 8%-21%; 24 hour five dose, 53% and 27%-66%; 48 hour four dose, 38% and 22%-48%; 48 hour six dose, 68% and 54%-77%; and 48 hour seven dose, 88% and 75%-98%. Sensitivity for the two radiologists for the identification of patients with polyps 1 cm or larger for each group was as follows: 24 hour two dose, 50% and 67%; 24 hour five dose, 100% and 100%; 48 hour four dose, 58% and 75%; 48 hour six dose, 56% and 67%; and 48 hour seven dose, 100% and 80%. CONCLUSION Ingestion of contrast material adequately labels stool for lesion identification; a 48-hour lead time and multiple doses of contrast material are required. Sensitivity for polyp detection in patients with adequate stool labeling approaches the sensitivity for polyp detection in prepared colons.
Collapse
Affiliation(s)
- M R Callstrom
- Department of Diagnostic Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Abstract
OBJECTIVE Our purpose is to describe associated and coexistent diseases of gastric carcinoid tumors, the unique biologic behavior of these tumors, the appearance of these tumors on fluoroscopic and CT images, and the radiologic management of these neoplasms. CONCLUSION First, multiple gastric carcinoid tumors are associated with enterochromaffin-like cell hyperplasia, chronic atrophic gastritis, and pernicious anemia and have a low risk of malignancy. Second, solitary gastric carcinoid tumors, or gastric carcinoid tumors associated with multiple endocrine neoplasia-type I (MEN-I) and Zollinger-Ellison syndrome, have a higher potential for metastatic disease. Third, the radiologic appearance and management of these tumors depend on the clinical background of the patient.
Collapse
Affiliation(s)
- A J Binstock
- Department of Radiology, Mayo Clinic, 200 First St. S.W., Mayo E2-B, Rochester, MN 55905, USA
| | | | | | | | | |
Collapse
|
34
|
Abstract
It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T(2) contrast at a given TR, or conversely to reduce TR by approximately 1000 msec and thus increase temporal resolution while maintaining a given level of contrast. Wiener demodulation of k-space data prior to reconstruction is shown to reduce blurring caused by T(2)-decay while constraining noise often associated with other inverse filters. Images are continuously acquired, reconstructed, and displayed at rates of one image every one to two seconds, while section position and contrast may be altered interactively. The clinical utility of this method is demonstrated with applications to dynamic pelvic floor imaging and interactive obstetric imaging.
Collapse
Affiliation(s)
- R F Busse
- Magnetic Resonance Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | | | | |
Collapse
|
35
|
Affiliation(s)
- J G Fletcher
- Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905, USA
| | | |
Collapse
|
36
|
Abstract
It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T(2) contrast at a given TR, or conversely to reduce TR by approximately 1000 msec and thus increase temporal resolution while maintaining a given level of contrast. Wiener demodulation of k-space data prior to reconstruction is shown to reduce blurring caused by T(2)-decay while constraining noise often associated with other inverse filters. Images are continuously acquired, reconstructed, and displayed at rates of one image every one to two seconds, while section position and contrast may be altered interactively. The clinical utility of this method is demonstrated with applications to dynamic pelvic floor imaging and interactive obstetric imaging.
Collapse
Affiliation(s)
- R F Busse
- Magnetic Resonance Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | | | | |
Collapse
|
37
|
Fletcher JG, Johnson CD, Welch TJ, MacCarty RL, Ahlquist DA, Reed JE, Harmsen WS, Wilson LA. Optimization of CT colonography technique: prospective trial in 180 patients. Radiology 2000; 216:704-11. [PMID: 10966698 DOI: 10.1148/radiology.216.3.r00au41704] [Citation(s) in RCA: 274] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE To assess the added benefits of prone positioning in addition to supine positioning and oral iodinated contrast medium for help in the detection of colonic polyps at computed tomographic (CT) colonography. MATERIALS AND METHODS CT colonography was performed in prone and supine positions in 180 patients with polyps or risk factors for colonic neoplasia. Patients were randomly assigned to receive a standard bowel preparation or a standard preparation plus oral iodinated contrast medium. One radiologist interpreted supine images alone, and another analyzed supine and prone images. All patients subsequently underwent colonoscopy. RESULTS At colonoscopy, 121 large (> or =1-cm-diameter) polyps and 142 smaller (0.5-0.9-cm) polyps were identified. Prone positioning resulted in increased sensitivity for identification of patients with large (> or =1-cm) polyps (increase from 70% to 85%, P: =.004) and of patients with polyps 0.5 cm or larger (increase from 75% to 88%, P: <.005), with no change in specificity. Use of oral contrast medium did not significantly improve polyp detection even in the subset of patients in whom colonic fluid attenuation was markedly increased. CONCLUSION Acquisition and review of supine and prone CT colonographic images significantly improves the ability to identify patients with polyps 0.5 cm in diameter or larger. Administration of oral iodinated contrast medium does not significantly improve polyp detection.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Diagnostic Radiology, Mayo Clinic and Mayo Foundation, Rochester, MN 55905, USA.
| | | | | | | | | | | | | | | |
Collapse
|
38
|
Abstract
With the introduction of multidetector technology in CT and the moveable table with integrated coil modules in MRI, the concept of multiorgan screening has become realistic. CT colonography and MR colonography are new radiologic techniques that promise to be highly sensitive colorectal screening examinations. This article reviews the current status and research directions in CT colonography and MR colonography, and compares these methods.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic Rochester, MN 55905, USA
| | | |
Collapse
|
39
|
Affiliation(s)
- J G Fletcher
- Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905, USA
| | | | | | | | | | | |
Collapse
|
40
|
Fossel ET, Zanella CL, Fletcher JG, Hui KK. Cell death induced by peroxidized low-density lipoprotein: endopepsis. Cancer Res 1994; 54:1240-8. [PMID: 8118812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Peroxidized low-density lipoprotein (p-LDL) has been previously demonstrated to be preferentially cytotoxic to certain malignant cells compared to normal cells of the same type. We present evidence that p-LDL is at least partially taken up through the LDL receptor and that it becomes localized in lysosomes. The integrity of lysosomes of p-LDL-treated cells is compromised, and leakage of their contents into the cytosol occurs. This leakage occurs early and precedes mitochondrial dysfunction. Brefeldin A inhibits this leakage, perhaps by interfering with the traffic between endosomes and lysosomes. Electron micrographs taken at various times suggest a mechanism of cell death which resembles certain aspects of the broad definition of apoptosis. However, we suggest that the cell death observed following p-LDL-induced release of lysosomal contents is essentially unique, with released lysosomal enzymes degrading the cell from within. We suggest that this process should be described as endopepsis.
Collapse
Affiliation(s)
- E T Fossel
- Department of Radiology, Beth Israel Hospital, Boston, MA 02215
| | | | | | | |
Collapse
|
41
|
Affiliation(s)
- J G Fletcher
- Queensland Department of Primary Industry, Rockhampton
| | | |
Collapse
|
42
|
Fossel ET, Fletcher JG, McDonagh J, Hui KK. Selective cytotoxicity of low-density lipoprotein to helper T cells of cutaneous T-cell lymphoma after photoperoxidation with 8-methoxypsoralen. J Natl Cancer Inst 1991; 83:1316-21. [PMID: 1832193 DOI: 10.1093/jnci/83.18.1316] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Lymphocyte-containing plasma subjected to photolysis in the presence of 8-methoxypsoralen (methoxsalen, 8-MOP) has previously been shown to be effective against cutaneous T-cell lymphoma and the AIDS-related complex. The mechanism of this effect was thought to involve photoreaction of 8-MOP with DNA, based on certain in vitro experiments. The results of this study suggest a different mechanism. Low-density lipoprotein (LDL) from fresh human plasma was photosensitized by addition of 8-MOP and exposure to UV light (mp-LDL), and the reactions of the LDL lipids and the chemical actions induced by these reactions were monitored. In a separate procedure, LDL was peroxidized with hydrogen peroxide and peroxidase (p-LDL). mp-LDL and p-LDL were then tested in cytotoxicity assays on HuT-78 helper T cells of cutaneous T-cell lymphoma. These results indicate that (a) LDL in plasma in the presence of very low concentrations of 8-MOP (200 ng/mL) can be peroxidized by UV light; (b) this photoperoxidized LDL is cytotoxic to helper T cells of cutaneous T-cell lymphoma in a dose-dependent manner; but (c) it does not kill normal lymphocytes under similar conditions. The findings also suggest alternative therapeutic strategies for treatment of cutaneous T-cell lymphoma, such as direct utilization of peroxidized LDL.
Collapse
Affiliation(s)
- E T Fossel
- Department of Radiology, Charles A. Dana Research Institute, Beth Israel Hospital, Boston, MA 02215
| | | | | | | |
Collapse
|
43
|
Abstract
In-air and in-phantom neutron spectra have been measured between 10 and 60 MeV for two field sizes on the Clatterbridge cyclotron by unfolding the response of a specially built NE213 scintillator. The in-phantom measurements show distinct spectral hardening with depth, which is reflected in changes in the spectrum-averaged mean neutron energy. These findings are confirmed using Monte Carlo calculations.
Collapse
Affiliation(s)
- N M Crout
- Medical Physics Group, School of Physics and Space Research, University of Birmingham, UK
| | | | | | | | | |
Collapse
|
44
|
|
45
|
Abstract
The reactions of 2-fluoro- and 3-fluoro-L-tyrosine with mushroom tyrosinase have been investigated. Both fluorinated tyrosines are good substrates for tyrosinase, with Vmax and Vmax/Km values similar to those for L-tyrosine. Oxygenation of 2-fluorotyrosine is regioselective, and only 6-fluorodopa was detected by HPLC in reaction mixtures. Oxygenation of both isomers of monofluorotyrosine results in fluoride ion production in the absence of ascorbic acid; however, 2-fluorotyrosine also produces fluoride in the presence of ascorbic acid. These results are consistent with previous studies demonstrating rapid intramolecular cyclization of nascent 6-fluorodopaquinone (M.E. Rice, B. Moghaddan, C.R. Creveling, and K.L. Kirk, 1987, Anal. Chem. 59, 1534-1538), which is competitive with reduction by ascorbate, resulting in elimination of the aromatic fluorine as fluoride ion.
Collapse
Affiliation(s)
- R S Phillips
- Department of Chemistry, School of Chemical Sciences, University of Georgia, Athens 30602
| | | | | | | |
Collapse
|
46
|
Fletcher EC, Luckett RA, Miller T, Fletcher JG. Exercise hemodynamics and gas exchange in patients with chronic obstruction pulmonary disease, sleep desaturation, and a daytime PaO2 above 60 mm Hg. Am Rev Respir Dis 1989; 140:1237-45. [PMID: 2817587 DOI: 10.1164/ajrccm/140.5.1237] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Nocturnal oxyhemoglobin desaturation (NOD) has been reported in patients with disease of the pulmonary parenchyma and/or chest wall. The resulting hypoxemia could play a role in the development of pulmonary hypertension. We have previously demonstrated a small but statistically significant difference in resting pulmonary artery pressure (Ppa) and pulmonary vascular resistance (PVR) between two groups of patients with COPD of similar age, symptomatology, and degree of pulmonary dysfunction. These two groups were selected only on the basis of the presence or absence of NOD, and all had a mean daytime PaO2 at or above 60 mm Hg. The present study uses exercise to stress the pulmonary circulation of two groups of patients similar to the above. The purpose was to see if exercise can amplify underlying cardiopulmonary hemodynamic differences between NOD and non-NOD subjects. In addition, we attempted to confirm or refute previous studies which claimed that exercise desaturation correlates with NOD. Resting supine, resting upright, and upright exercise cardiopulmonary hemodynamics were measured using an indwelling right heart catheter, and arterial blood and expiratory gases were collected to assess metabolic and other gas exchange parameters. Although both groups showed increase in Ppa during exercise, the increases in systolic Ppa, mean Ppa, and driving pressure were disparately higher in subjects with NOD. Exercise desaturation was not predictive of NOD. The presence of NOD was predictive of a resting PVR greater than 120 dyne.s.cm-5, whereas mean sleep SaO2 and daytime PaO2 were unable to discriminate patients with COPD above or below this level.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- E C Fletcher
- Department of Medicine, Houston Veterans Administration Medical Center 77211
| | | | | | | |
Collapse
|
47
|
Fletcher EC, Luckett RA, Miller T, Costarangos C, Kutka N, Fletcher JG. Pulmonary vascular hemodynamics in chronic lung disease patients with and without oxyhemoglobin desaturation during sleep. Chest 1989; 95:757-64. [PMID: 2924605 DOI: 10.1378/chest.95.4.757] [Citation(s) in RCA: 97] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Nonapneic, nocturnal oxyhemoglobin desaturation (NOD) during rapid-eye-movement (REM) sleep has been proposed as a predecessor and possible etiologic factor in the development of pulmonary hypertension in patients both with restrictive and obstructive chronic lung disease. The association between abnormal waking cardiopulmonary hemodynamics and NOD has not been established in patients with mild daytime hypoxemia. Gas exchange, pulmonary function, red cell mass, radionuclide gated cardiac ejection fraction, and supine cardiopulmonary hemodynamics were examined in 36 patients with chronic lung disease. All had a daytime PaO2 greater than 60 mm Hg and REM sleep-related NOD for greater than 5 minutes, to 85 percent or lower. These data were compared to those from 13 subjects with similar symptoms and objective measures of pulmonary dysfunction but without evidence of NOD. Patients with NOD showed more end organ evidence of hypoxemia and more abnormal cardiopulmonary hemodynamics than patients with similar degrees of lung disease but without NOD. The relative role of daytime vs nocturnal hypoxemia in inducing hemodynamic differences between groups cannot be determined from this study.
Collapse
Affiliation(s)
- E C Fletcher
- Department of Medicine, Houston Veterans Administration Medical Center, TX 77030
| | | | | | | | | | | |
Collapse
|
48
|
Fletcher EC, Miller J, Divine GW, Fletcher JG, Miller T. Nocturnal oxyhemoglobin desaturation in COPD patients with arterial oxygen tensions above 60 mm Hg. Chest 1987; 92:604-8. [PMID: 3652746 DOI: 10.1378/chest.92.4.604] [Citation(s) in RCA: 138] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
We studied 152 COPD patients with a daytime PaO2 greater than or equal to 60 mm Hg using formal polysomnography (EEG, airflow, respiratory muscle movement, ear oximeter) to detect the presence of nocturnal, nonapneic, oxyhemoglobin desaturation. Nine subjects were disqualified by the unexpected discovery of sleep apnea, as were another eight because they could not sleep in the laboratory setting. Of the remaining 135 subjects, 37 (27 percent) desaturated below a baseline sleep saturation of 90 percent for five minutes or more, reaching a nadir saturation of at least 85 percent. Anthropomorphic, pulmonary function, and historic factors comparing desaturators and nondesaturators failed to separate the groups. Awake PaO2 at rest in the desaturators was significantly lower than in the nondesaturators. The PaCO2 was higher in the desaturators. Reversibility of the desaturation phenomenon was demonstrated in three patients during subsequent polysomnographic studies following periods of clinical improvement. Continuous oxyhemoglobin monitoring during sleep remains the only reliable tool for detecting nocturnal desaturation.
Collapse
Affiliation(s)
- E C Fletcher
- Department of Medicine, Houston Veterans Administration Medical Center 77211
| | | | | | | | | |
Collapse
|
49
|
Fletcher EC, Schaaf JW, Miller J, Fletcher JG. Long-term cardiopulmonary sequelae in patients with sleep apnea and chronic lung disease. Am Rev Respir Dis 1987; 135:525-33. [PMID: 3826878 DOI: 10.1164/arrd.1987.135.3.525] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Both obstructive sleep apnea and chronic lung disease can be associated with intermittent or chronic hypoxemia leading to pulmonary hypertension and cor pulmonale. When these problems coexist, it is possible that the cardiopulmonary effects are additive. We hypothesized that hemodynamic disturbances in patients with apnea and lung disease would be more severe than in those with apnea alone, and that hemodynamic improvement should follow apnea cure, but perhaps at a slower rate than in those with apnea alone. To test these hypotheses, we prospectively followed 24 patients with sleep apnea syndrome. They were divided into 3 nonrandomized groups. Nineteen patients had both apnea and lung disease. Nine of these agreed to curative tracheostomy (Group 1). The other 10 subjects (Group 2) refused tracheostomy but accepted noncurative therapies, including nocturnal oxygen (n = 9), uvulopalatopharyngoplasty (n = 2), and protriptyline (n = 4). Five subjects with apnea but without clinically obvious lung disease received tracheostomies (Group 3). Subjects were followed at yearly intervals (mean follow-up, 27.2 months) with radionuclide motion studies and, in 15 of 24 who consented, right heart catheterization. The 3 groups did not vary with respect to age, percent ideal weight, or severity of apnea symptoms. The severity of right-sided hemodynamic dysfunction in the group with apnea but no obvious lung disease was less than that in the 2 groups with lung disease. A substantial decrease in pulmonary artery pressure (p = 0.056) and significant improvement in right ventricular ejection fraction occurred in the tracheostomized group with both apnea and lung disease. Pulmonary vascular resistance decreased in both groups receiving tracheostomy.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
50
|
Fletcher EC, Miller J, Schaaf JW, Fletcher JG. Urinary catecholamines before and after tracheostomy in patients with obstructive sleep apnea and hypertension. Sleep 1987; 10:35-44. [PMID: 3563246 DOI: 10.1093/sleep/10.1.35] [Citation(s) in RCA: 231] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Obstructive apnea (asphyxia) is accompanied by acute elevation of systemic blood pressure. The usual nocturnal fall in blood pressure seen during sleep in normals may be absent in patients with repetitive apneas, and daytime systemic hypertension is reported to occur in up to 90% of such patients. Increased sympathetic activity in response to repetitive nocturnal episodes of asphyxia could explain the reversal of the diurnal pressure variation but not the daytime systemic hypertension in this setting. We examined diurnal variation in urinary catecholamines in eight subjects with severe apnea before and after tracheostomy. Five obese hypertensive subjects without apnea served as controls. Three urine specimens, two awake (7 a.m. to 3 p.m. and 3 p.m. to 11 p.m.) and one asleep (11 p.m. to 7 a.m.) were collected preoperatively and again 10-14 days postoperatively when the patient was free of pain and signs of stoma infection. All specimens were analyzed for epinephrine, norepineprine, metanephrine, and normetanephrine by liquid chromatography with electrochemical detection. Urinary epinephrine and metanephrine were not different between subjects and controls. Norepinephrine and normetanephrine were significantly higher in apneic subjects pretracheostomy as compared either with controls or with their own values posttracheostomy. Diurnal variation was not seen before or after tracheostomy. Only two of the controls showed significant diurnal variation in norepinephrine. We conclude that the absence of diurnal variation in catecholamines prior to tracheostomy reflects increased nocturnal sympathetic activity. Elevation of daytime norepinephrine and normetanephrine with return to control levels following tracheostomy implies increased sympathetic activity throughout the day.
Collapse
|