Caruso D, De Santis D, Tremamunno G, Santangeli C, Polidori T, Bona GG, Zerunian M, Del Gaudio A, Pugliese L, Laghi A. Deep learning reconstruction algorithm and high-concentration contrast medium: feasibility of a double-low protocol in coronary computed tomography angiography. Eur Radiol 2024:10.1007/s00330-024-11059-x. [PMID: 39299952 DOI: 10.1007/s00330-024-11059-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 06/28/2024] [Accepted: 08/16/2024] [Indexed: 09/22/2024]
Abstract
OBJECTIVE To evaluate radiation dose and image quality of a double-low CCTA protocol reconstructed utilizing high-strength deep learning image reconstructions (DLIR-H) compared to standard adaptive statistical iterative reconstruction (ASiR-V) protocol in non-obese patients. MATERIALS AND METHODS From June to October 2022, consecutive patients, undergoing clinically indicated CCTA, with BMI < 30 kg/m2 were prospectively included and randomly assigned into three groups: group A (100 kVp, ASiR-V 50%, iodine delivery rate [IDR] = 1.8 g/s), group B (80 kVp, DLIR-H, IDR = 1.4 g/s), and group C (80 kVp, DLIR-H, IDR = 1.2 g/s). High-concentration contrast medium was administered. Image quality analysis was evaluated by two radiologists. Radiation and contrast dose, and objective and subjective image quality were compared across the three groups. RESULTS The final population consisted of 255 patients (64 ± 10 years, 161 men), 85 per group. Group B yielded 42% radiation dose reduction (2.36 ± 0.9 mSv) compared to group A (4.07 ± 1.2 mSv; p < 0.001) and achieved a higher signal-to-noise ratio (30.5 ± 11.5), contrast-to-noise-ratio (27.8 ± 11), and subjective image quality (Likert scale score: 4, interquartile range: 3-4) compared to group A and group C (all p ≤ 0.001). Contrast medium dose in group C (44.8 ± 4.4 mL) was lower than group A (57.7 ± 6.2 mL) and B (50.4 ± 4.3 mL), all the comparisons were statistically different (all p < 0.001). CONCLUSION DLIR-H combined with 80-kVp CCTA with an IDR 1.4 significantly reduces radiation and contrast medium exposure while improving image quality compared to conventional 100-kVp with 1.8 IDR protocol in non-obese patients. CLINICAL RELEVANCE STATEMENT Low radiation and low contrast medium dose coronary CT angiography protocol is feasible with high-strength deep learning reconstruction and high-concentration contrast medium without compromising image quality. KEY POINTS Minimizing the radiation and contrast medium dose while maintaining CT image quality is highly desirable. High-strength deep learning iterative reconstruction protocol yielded 42% radiation dose reduction compared to conventional protocol. "Double-low" coronary CTA is feasible with high-strength deep learning reconstruction without compromising image quality in non-obese patients.
Collapse
Affiliation(s)
- Damiano Caruso
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Domenico De Santis
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Giuseppe Tremamunno
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Curzio Santangeli
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Tiziano Polidori
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Giovanna G Bona
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Marta Zerunian
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Antonella Del Gaudio
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Luca Pugliese
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Andrea Laghi
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy.
| |
Collapse
|
2
|
Liu S, Huang L, Gui S, Pang X, Liu J, Li X, Wang Y, He W, Zhang X, Peng L. Optimizing coronary CT angiography quality with motion-compensated reconstruction for second-generation dual-layer spectral detector CT. Eur Radiol 2024:10.1007/s00330-024-10908-z. [PMID: 38987398 DOI: 10.1007/s00330-024-10908-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 04/25/2024] [Accepted: 05/07/2024] [Indexed: 07/12/2024]
Abstract
OBJECTIVES To investigate the effect of motion-compensated reconstruction (MCR) algorithm on improving the image quality of coronary computed tomography angiography (CCTA) using second-generation dual-layer spectral detector computed tomography (DLCT), and to evaluate the influence of heart rate (HR) on the motion-correction efficacy of this algorithm. MATERIALS AND METHODS We retrospectively enrolled 127 patients who underwent CCTA for suspected coronary artery disease using second-generation DLCT. We divided the patients into two subgroups according to their average HR during scanning: the "HR < 75 bpm" group and the "HR ≥ 75 bpm" group. All images were reconstructed by the standard (STD) algorithm and MCR algorithm. Subjective image quality (4-point Likert scale), interpretability, and objective image quality between the STD and MCR in the whole population and within each subgroup were compared. RESULTS MCR showed significantly higher Likert scores and interpretability than STD on the per-segment (3.58 ± 0.69 vs. 2.82 ± 0.93, 98.4% vs. 91.9%), per-vessel (3.12 ± 0.81 vs. 2.12 ± 0.74, 96.3% vs. 78.7%) and per-patient (2.57 ± 0.76 vs. 1.62 ± 0.55, 90.6% vs. 59.1%) levels (all p < 0.001). In the analysis of HR subgroups on a per-vessel basis of interpretability, significant differences were observed only in the right coronary artery in the low HR group, whereas significant differences were noted in three major coronary arteries in the high HR group. For objective image quality assessment, MCR significantly improved the SNR (13.22 ± 4.06 vs. 12.72 ± 4.06) and the contrast-to-noise ratio (15.84 ± 4.82 vs. 15.39 ± 4.38) compared to STD (both p < 0.001). CONCLUSION MCR significantly improves the subjective image quality, interpretability, and objective image quality of CCTA, especially in patients with higher HRs. CLINICAL RELEVANCE STATEMENT The motion-compensated reconstruction algorithm of the second-generation dual-layer spectral detector computed tomography is helpful in improving the image quality of coronary computed tomography angiography in clinical practice, especially in patients with higher heart rates. KEY POINTS Motion artifacts from cardiac movement affect the quality and interpretability of coronary computed tomography angiography (CCTA). This motion-compensated reconstruction (MCR) algorithm significantly improves the image quality of CCTA in clinical practice. Image quality improvement by using MCR was more significant in the high heart rate group.
Collapse
Affiliation(s)
- Shengmei Liu
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
- Department of Radiology, Sichuan Taikang Hospital, Chengdu, 610041, Sichuan, China
| | - Linyan Huang
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
| | - Shen Gui
- Department of Clinical Science, Philips Healthcare, Shanghai, China
| | - Xueting Pang
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
| | - Jing Liu
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
| | - Xue Li
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
| | - Yinqiu Wang
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
| | - Wenzhang He
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China
| | - Xiaodi Zhang
- Department of Clinical Science, Philips Healthcare, Shanghai, China
| | - Liqing Peng
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, 610041, China.
| |
Collapse
|
3
|
Sakrana AA, Alharbi IH, Elmokadem AH. Diagnostic accuracy of lower-dose cardiac CT in evaluating young infants with non-coronary complex congenital heart disease on a 64-slice multidetector CT scanner. Acta Radiol 2022; 64:2024-2032. [PMID: 36451522 DOI: 10.1177/02841851221139672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Background Redoable precise and non-invasive diagnostic imaging modality with the least radiation dose is essential for infants with congenital heart disease (CHD) . Purpose To investigate the accuracy and estimate the radiation dose of our cardiac computed tomography (CCT) protocol. Material and Methods A total of 82 infants with CHD underwent non-ECG-gated CCT without contrast timing scanning techniques and were retrospectively studied. The image quality and radiation dose were estimated. The radiation dose was compared statistically to virtual retrospective ECG-gated and prospective ECG-triggering scanning modes. The diagnostic accuracy was assessed assuming the surgical results as the diagnostic gold standard. Results Most exams showed a high quality with low radiation doses compared to previous studies. The mean effective dose (ED) was 0.39 ± 1.2, significantly lower than that of the virtual retrospective ECG-gated and prospective ECG-triggering scanning and lower than in previous studies. Our CCT protocol has achieved a diagnostic accuracy of 99.52% with a sensitivity of 94.83% and specificity of 99.91%. Conclusion Non-ECG-gated CCT without contrast timing techniques can detect the non-coronary cardiovascular defects of CHD in infants with an ultralow radiation dose and a high diagnostic accuracy.
Collapse
Affiliation(s)
- Amal Abdelsattar Sakrana
- Department of Diagnostic and Interventional radiology, Mansoura University Hospital, Mansoura, Egypt
| | | | - Ali H Elmokadem
- Department of Diagnostic and Interventional radiology, Mansoura University Hospital, Mansoura, Egypt
| |
Collapse
|
4
|
Ippolito D, Talei Franzesi C, Cangiotti C, Riva L, De Vito A, Gandola D, Maino C, Marra P, Muscogiuri G, Sironi S. Inter-observer agreement and image quality of model-based algorithm applied to the Coronary Artery Disease-Reporting and Data System score. Insights Imaging 2022; 13:176. [PMID: 36399289 PMCID: PMC9674810 DOI: 10.1186/s13244-022-01286-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 08/24/2022] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To evaluate the inter-observer agreement of the CAD-RADS reporting system and compare image quality between model-based iterative reconstruction algorithm (MBIR) and standard iterative reconstruction algorithm (IR) of low-dose cardiac computed tomography angiography (CCTA). METHODS One-hundred-sixty patients undergone a 256-slice MDCT scanner using low-dose CCTA combined with prospective ECG-gated techniques were enrolled. CCTA protocols were reconstructed with both MBIR and IR. Each study was evaluated by two readers using the CAD-RADS lexicon. Vessels enhancement, image noise, signal-to-noise (SNR), and contrast-to-noise (CNR) were computed in the axial native images, and inter-observer agreement was assessed. Radiation dose exposure as dose-length product (DLP) and effective dose were finally reported. RESULTS The reliability analysis between the two readers was almost perfect for all CAD-RADS standard categories. Moreover, a significantly higher value of subjective qualitative analysis, SNR, and CNR in MBIR images compared to IR were found, due to a lower noise level (all p < 0.05). The mean DLP measured was 63.9 mGy*cm, and the mean effective dose was 0.9 mSv. CONCLUSION Inter-observer agreement of CAD-RADS was excellent confirming the importance, the feasibility, and the reproducibility of the CAD-RADS scoring system for CCTA. Moreover, lower noise and higher image quality with MBIR compared to IR were found. IMPLICATIONS FOR PRACTICE MBIR, by reducing noise and improving image quality, can help a better assessment of CAD-RADS, in comparison with standard IR algorithm.
Collapse
Affiliation(s)
- Davide Ippolito
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy.
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy.
| | - Cammillo Talei Franzesi
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Cecilia Cangiotti
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Luca Riva
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Andrea De Vito
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Davide Gandola
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Cesare Maino
- Department of Diagnostic Radiology, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Paolo Marra
- Department of Diagnostic Radiology, H Papa Giovanni XXIII, Piazza OMS 1, 24127, Bergamo, BG, Italy
| | - Giuseppe Muscogiuri
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
- IRCCS, Istituto Auxologico Italiano, Milan, Italy
| | - Sandro Sironi
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
- Department of Diagnostic Radiology, H Papa Giovanni XXIII, Piazza OMS 1, 24127, Bergamo, BG, Italy
| |
Collapse
|
5
|
Butaish Z, Alajmi M, Elahi A, Bafaraj SM. Evaluation of Cardiac Scan in Diagnosing Coronary-artery Disease. Curr Med Imaging 2021; 16:1022-1028. [PMID: 32473003 DOI: 10.2174/1573405616666200530211415] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 05/07/2020] [Accepted: 05/11/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND With the evaluation of focal epicardial coronary stenosis and non-obstructive atherosclerosis, the cardiac scans play a significant role in diagnosing coronary artery disease (CAD). Moreover, the advancements in the imaging techniques leading to improved risk assessment and timely therapies help in early diagnosis of CAD with greater accuracy. AIMS To evaluate the role of cardiac scan in diagnosing CAD. METHODS Recruited 100 individuals without any history of CAD that refers to the assessment of suspected angina, conducted the prospective study. Electrocardiogram (ECG) findings assisted in the evaluation of left bundle branch blockage, abnormalities of ST-segment, and pathological Q waves. RESULTS The results depicted negative N.M findings among 38 respondents; whereas, ischemia and myocardial infarctions were diagnosed in 26% and 19% of the respondents, respectively. The majority of the males (59) were positive in contrast to 37 females with positive results. Similarly, 24 respondents were presented with mild dilated left atria (LA), 37 respondents suffered from impaired relaxation pattern of left ventricular (LV) diastolic filling; while, 40 of the respondents had normal global LV systolic function. CONCLUSION The study results have concluded that non-invasive, low-risk, and cost-effective technique like ECG is an important beneficial advancement in the diagnosis of CAD.
Collapse
Affiliation(s)
- Zubaida Butaish
- Diagnostic Radiology Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Masheal Alajmi
- Diagnostic Radiology Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Arouba Elahi
- Diagnostic Radiology Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Saeed M Bafaraj
- Diagnostic Radiology Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
6
|
Mansour HH, Alajerami YS, Foster T. Estimation of Radiation Doses and Lifetime Attributable Risk of Radiation-induced Cancer from A Single Coronary Artery Bypass Graft Computed Tomography Angiography. ELECTRONIC JOURNAL OF GENERAL MEDICINE 2021. [DOI: 10.29333/ejgm/11208] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
7
|
Richards CE, Obaid DR. Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease. Curr Cardiol Rev 2019; 15:304-315. [PMID: 30806322 PMCID: PMC8142354 DOI: 10.2174/1573403x15666190222163737] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/24/2018] [Accepted: 12/26/2018] [Indexed: 01/16/2023] Open
Abstract
Background
Coronary computed tomography angiography (CCTA) is now widely used in the diagnosis of coronary artery disease since it is a rapid, minimally invasive test with a diagnostic accuracy comparable to coronary angiography. However, to meet demands for increasing spatial and temporal resolution, higher x-ray radiation doses are required to circumvent the resulting increase in image noise. Exposure to high doses of ionizing radiation with CT imaging is a major health concern due to the potential risk of radiation-associated malignancy. Given its increasing use, a number of dose saving algorithms have been implemented to CCTA to minimize radiation exposure to “as low as reasonably achievable (ALARA)” without compromising diagnostic image quality. Objective
The purpose of this review is to outline the most recent advances and current status of dose saving techniques in CCTA. Method
PubMed, Medline, EMBASE and Scholar databases were searched to identify feasibility studies, clinical trials, and technology guidelines on the technical advances in CT scanner hardware and reconstruction software. Results
Sub-millisievert (mSv) radiation doses have been reported for CCTA due to a combination of strategies such as prospective electrocardiogram-gating, high-pitch helical acquisition, tube current modulation, tube voltage reduction, heart rate reduction, and the most recent novel adaptive iterative reconstruction algorithms. Conclusion
Advances in radiation dose reduction without loss of image quality justify the use of CCTA as a non-invasive alternative to coronary catheterization in the diagnosis of coronary artery disease.
Collapse
Affiliation(s)
- Caryl E Richards
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom
| | - Daniel R Obaid
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom.,Swansea University Medical School, Swansea University, Grove Building, Singleton Park, Sketty, Swansea SA2 8PP, United Kingdom
| |
Collapse
|
8
|
Rawashdeh M, Saade C, Zaitoun M, Abdelrahman M, Brennan P, Alewaidat H, McEntee MF. Establishment of diagnostic reference levels in cardiac computed tomography. J Appl Clin Med Phys 2019; 20:181-186. [PMID: 31469229 PMCID: PMC6807208 DOI: 10.1002/acm2.12711] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Revised: 08/03/2019] [Accepted: 08/07/2019] [Indexed: 11/14/2022] Open
Abstract
The aim of this study was to determine diagnostic reference levels (DRLs) for cardiac computed tomography (CCT) in Jordan. Volume computed tomography dose index (CTDIvol) and dose–length product (DLP) were collected from 228 CCTs performed at seven Jordanian hospitals specialized in cardiac CT. DRLs for cardiac CT were defined at the 75th percentile of CTDIvol and DLP. CTDIvol and DLP were collected from 30 successive cardiac CT in each center except for one center (18 scans). The 75th percentile of the CTDIvol and the DLP of the centers calculated from mixed retrospective and prospective gated modes were 47.74 milligray (mGy) and 1035 mGy/cm, respectively. This study demonstrated wide dose variations among the surveyed hospitals for cardiac CT scans; there was a 5.1‐fold difference between the highest and lowest median DLP with a range of 223.2–1146.7 mGy/cm. Differences were associated with variations in the mAs and kVp. This study confirmed large variability in CTDIvol and DLP for cardiac CT scans; variation was associated with acquisition protocols and highlights the need for dose optimization. DRLs are proposed for CCT; there remains substantial potential for optimization of cardiac CT examinations for adults in Jordan.
Collapse
Affiliation(s)
- Mohammad Rawashdeh
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Charbel Saade
- Department of Diagnostic Radiology, American University of Beirut Medical Center, Beirut, Lebanon
| | - Maha Zaitoun
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Mostafa Abdelrahman
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Patrick Brennan
- Faculty of Health Sciences, Medical Image Optimization and Perception Group (MIOPeG), and the Brain and Mind Centre, The University of Sydney, Sydney, NSW, Australia
| | - Haytham Alewaidat
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Mark F McEntee
- Discipline of Diagnostic Radiography, UG 12 Aras Watson, Brookfield Health Sciences, University College Cork, College Road, Cork, Ireland
| |
Collapse
|
9
|
Yang CC, Law WY, Lu KM, Wu TH. Relationship between heart rate and optimal reconstruction phase in coronary CT angiography performed on a 256-slice multidetector CT. Br J Radiol 2019; 92:20180945. [PMID: 31322906 DOI: 10.1259/bjr.20180945] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVE This study aimed to evaluate the relationship between heart rate (HR) and optimal reconstruction phase in prospectively electrocardiogram (ECG)-triggered coronary CT angiography (CCTA) performed on a newly introduced 256-slice multidetector CT (MDCT). METHODS All the cases were selected retrospectively from the patients scheduled for CCTA in our department between January and April 2017. The scanner selected the optimal exposure phase based on 10 s ECG recordings. To ensure the success of CCTA, the operator also checked patient's age, breathing control, emotional status and past medical history to decide whether the automatically selected scan phase needs manual adjustment or not. Images were reconstructed in 1% steps of the R-R interval to determine the cardiac phase with least coronary motion. If CCTA images showed moderate motion blurring or discontinuity in the course of coronary segments, a cardiac motion correction algorithm was applied to the reconstructed images. Subjective diagnostic image quality was evaluated with 4-point grading scale. RESULTS A total of 87 consecutive CCTA examinations were investigated in this study. Diastolic reconstruction was applied to all vessel segments in patients with HR <63 bpm, where 36.5 and 77.8% of vessel segments were reconstructed with the use of motion correction in HR ≤57 and 58-62 bpm, respectively. As for patients with HR ≥63 bpm, 89.3 and 71.7% of vessel segments were reconstructed in diastole in HR 63-67 and ≥68 bpm, respectively, while 81 and 100% of vessel segments were reconstructed with the use of motion correction in the same HR groups. CONCLUSION Based on our results, a HR less than 67 bpm can be used to identify appropriate patients for diastolic reconstruction. Although the motion correction algorithm is an effective approach to reduce the impact of cardiac motion in CCTA, HR control is still important to optimize the image quality of CCTA. The relationship between HR and optimal reconstruction phase established in this study could be further used to tailor the ECG pulsing window for dose reduction in patients undergoing CCTA performed on the 256-slice MDCT. ADVANCES IN KNOWLEDGE The HR thresholds to identify patients who are the best suitable candidates for diastolic or systolic reconstruction are scanner specific. This study investigated the relationship between HR and optimal reconstruction phase in prospectively ECG-triggered CCTA for a newly introduced 256-slice MDCT. Once the relationship is established, it could be used to tailor the ECG pulsing window for radiation dose reduction.
Collapse
Affiliation(s)
- Ching-Ching Yang
- 1Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Wei-Yip Law
- 2Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan
| | - Kun-Mu Lu
- 2Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan
| | - Tung-Hsin Wu
- 3Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan
| |
Collapse
|
10
|
Gunther-Harrington CT, Phillips KL, Visser LC, Fousse SL, Stern JA. Non-electrocardiographic-gated computed tomographic angiography can be used to diagnose coronary artery anomalies in Bulldogs with pulmonary valve stenosis. Vet Radiol Ultrasound 2018; 60:38-46. [DOI: 10.1111/vru.12689] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 07/20/2018] [Accepted: 07/21/2018] [Indexed: 12/11/2022] Open
Affiliation(s)
- Catherine T. Gunther-Harrington
- Department of Medicine and Epidemiology; School of Veterinary Medicine; University of California, Davis; Davis California 95616
| | - Kathryn L. Phillips
- Department of Surgical and Radiological Sciences; School of Veterinary Medicine; University of California, Davis; Davis California 95616
| | - Lance C. Visser
- Department of Medicine and Epidemiology; School of Veterinary Medicine; University of California, Davis; Davis California 95616
| | - Samantha L. Fousse
- Department of Medicine and Epidemiology; School of Veterinary Medicine; University of California, Davis; Davis California 95616
| | - Joshua A. Stern
- Department of Medicine and Epidemiology; School of Veterinary Medicine; University of California, Davis; Davis California 95616
| |
Collapse
|
11
|
Velankar P, Chaikriangkrai K, Dewal N, Bala SK, Elferjani B, Alchalabi S, Chang SM. Prognostic Performance of Prospective versus Retrospective Electrocardiographic Gating in Coronary Computed Tomographic Angiography. Tex Heart Inst J 2018; 45:214-220. [PMID: 30374228 DOI: 10.14503/thij-17-6270] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Coronary computed tomographic angiography (CCTA) with prospective electrocardiographic gating reduces radiation exposure, but its prognostic power for predicting cardiovascular risk in patients with suspected CAD has not been fully validated. To determine whether prospective gating performs as well as retrospective gating in this population, we compared these scan modes in patients undergoing 64-slice CCTA. From January 2009 through September 2011, 1,407 patients underwent CCTA; of these, 915 (mean age, 57.8 ± 13.5 yr; 54% male) had suspected coronary artery disease at the time of CCTA and were included in the study. Prospective gating was used in 195 (21%) and retrospective gating in 720 (79%). The mean follow-up duration was 2.4 ± 0.9 years. Overall, 390 patients (42.6%) had normal results on CCTA, 382 (41.7%) had nonobstructive coronary artery disease, and 143 (15.6%) had obstructive disease. Major adverse cardiac events occurred in 32 patients (3.5%): 11 cardiac deaths, 15 late revascularizations, and 6 nonfatal myocardial infarctions. Total event occurrences were similar in both groups (retrospective, 3.8%; prospective, 2.6%; P=0.42), as were the occurrences of each type of event. On adjusted multivariate analysis, nonobstructive (P=0.015) and obstructive (P <0.001) coronary artery disease were independently associated with major adverse cardiac events. Scan mode was not a predictor of outcome. The mean effective radiation dose was 4 ± 2 mSv for prospective compared with 12 ± 4 mSv for retrospective gating (P <0.01). The prognostic value of CCTA with prospective electrocardiographic gating compares favorably with that of retrospective gating, and it involves significantly less radiation exposure.
Collapse
|
12
|
Smettei OA, Sayed S, M Al Habib A, Alharbi F, Abazid RM. Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure. J Saudi Heart Assoc 2018; 30:165-171. [PMID: 29983492 PMCID: PMC6026393 DOI: 10.1016/j.jsha.2017.11.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 09/27/2017] [Accepted: 11/02/2017] [Indexed: 01/08/2023] Open
Abstract
Background Coronary computed tomography angiography (CCTA) is increasingly being used for the evaluation of coronary artery disease; however, radiation exposure remains a major limitation of its use. Objective To compare image quality and radiation exposure in two groups of patients undergoing CCTA using a 256-slice dual-source helical computed tomography scanner with high-pitch (FLASH) or prospective [step-and-shoot (SAS)] gating protocols. Methods A prospective, single-center study was performed in our cardiac center. In total, 162 patients underwent CCTA with either FLASH or SAS scanning protocols. Subjective image quality was graded on the basis of a four-point grading system (1, non-diagnostic; 2, adequate; 3, good; 4, excellent). Objective image quality was assessed using image signal, noise, and signal-to-noise ratio (SNR). The effective radiation dose was also estimated. Results The clinical and demographic characteristics of the patients in both groups were similar. The median age of the patients in both groups was 48.43 years, and males accounted for 63% and 68.7% of the FLASH and SAS groups, respectively. We found that the subjective image quality obtained with the FLASH protocol was superior to that obtained with the SAS protocol (3.35 ± 0.6 mSv vs. 2.82 ± 0.61 mSv; p < 0.001). Image noise was higher in the FLASH group but was not statistically significant (25.0 ± 6.13 vs. 24.0 ± 6.8; p = 0.10), whereas the signal and SNR was significantly higher with the FLASH protocol than with the SAS protocol [(469 ± 116 vs. 397 ± 106; p > 0.001) and (21.6 ± 8.7 mSv vs. 16.6 ± 7.7 mSv; p < 0.001), respectively]. Radiation exposure was 62% lower in the FLASH protocol than in the SAS protocol, (1.9 ± 0.4 mSv vs. 5.12 ± 1.8 mSv; p < 0.001). Conclusion The use of 256-slice CCTA performed with the FLASH protocol has a better objective and subjective image quality as well as lower radiation exposure when compared with the use of prospective electrocardiography gating.
Collapse
Affiliation(s)
- Osama A Smettei
- Department of Cardiology, Cardiac Imaging Department, Prince Sultan Cardiac Center, Qassim PSCCQ, Buraydah, Saudi Arabiaa
| | - Sawsan Sayed
- Department of Cardiology, Cardiac Imaging Department, Prince Sultan Cardiac Center, Qassim PSCCQ, Buraydah, Saudi Arabiaa
| | - Abdullah M Al Habib
- Department of Radiology, King Fahad Specialist Hospital, Qassim, Saudi Arabiab
| | - Fahad Alharbi
- Department of Radiology, King Fahad Specialist Hospital, Qassim, Saudi Arabiab
| | - Rami M Abazid
- Department of Cardiology, Cardiac Imaging Department, Prince Sultan Cardiac Center, Qassim PSCCQ, Buraydah, Saudi Arabiaa
| |
Collapse
|
13
|
Low-dose paediatric cardiac and thoracic computed tomography with prospective triggering: Is it possible at any heart rate? Phys Med 2018; 49:99-104. [PMID: 29866350 DOI: 10.1016/j.ejmp.2018.05.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 04/20/2018] [Accepted: 05/11/2018] [Indexed: 11/20/2022] Open
Abstract
OBJECTIVE To demonstrate that the use of step-and-shoot (SAS) mode in paediatric cardiac CT angiography (CCTA) is possible at heart rates (HR) greater than 65 bpm, allowing low-dose acquisition with single-source 64-slices CT. METHODS We retrospectively included 125 paediatric patients (0-6 years). CCTA was performed with SAS at diastolic phase in 31 patients (group D, HR < 65 bpm), at systolic phase in 45 patients (group S, HR ≥ 65 bpm) and with non-gated mode in 49 patients (group NG). Effective dose (ED) and image quality using a 3-grade scoring scale (1, excellent; 2, moderate; 3, insufficient) of group S were compared with group D for coronary examinations and group NG for entire thorax vascular anatomy. RESULTS For coronary indications, median ED was 0.6 mSv in group D versus 0.9 mSv in group S (p < 0.01). For whole thorax indications, median ED was 2.7 mSv in group NG versus 1.1 mSv in group S (p < 0.001). The mean image quality score was (1.4 ± 0.6) points in group D, (1.4 ± 0.7) in group S for coronary indications (p = 0.9), (1.3 ± 0.6) in group S for whole thorax indications and (2.0 ± 0.0) in group NG (p < 0.001). CONCLUSION SAS mode is feasible in children with HR greater than 65 bpm allowing low-dose CCTA. It provided comparable image quality in systole, compared to diastole. SAS at the systolic phase provided better image quality with less radiation dose compared to non-gated scans for whole thorax examinations.
Collapse
|
14
|
Image Quality, Overall Evaluability, and Effective Radiation Dose of Coronary Computed Tomography Angiography With Prospective Electrocardiographic Triggering Plus Intracycle Motion Correction Algorithm in Patients With a Heart Rate Over 65 Beats Per Minute. J Thorac Imaging 2018; 33:225-231. [PMID: 29346192 DOI: 10.1097/rti.0000000000000320] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE Recently, a new intracycle motion correction algorithm (MCA) was introduced to reduce motion artifacts from heart rate (HR) in coronary computed tomography angiography (cCTA). The aim of the study was to evaluate the image quality, overall evaluability, and effective radiation dose (ED) of cCTA with prospective electrocardiographic (ECG) triggering plus MCA as compared with standard protocol with retrospective ECG triggering in patients with HR≥65 bpm. MATERIALS AND METHODS One hundred consecutive patients (67±10 y) scheduled for cCTA with 65<HR<80 bpm were retrospectively analyzed. The patients were assigned to 2 groups undergoing prospective (group 1) or retrospective (group 2) triggered cCTA. The study protocol was approved by the Institutional Ethics Committee and a written informed consent was obtained from all patients. Image noise, signal to noise ratio, contrast to noise ratio, Likert image quality score (score 1, nondiagnostic; score 2, adequate; score 3, good; score 4, excellent), overall image evaluability, and ED were measured and compared between the 2 groups. Both vessel-based and patient-based analyses were evaluated. Student test or Wilcoxon test were used to evaluate differences of continuous variables, whereas the χ test was used to study differences with regard to categorical data. A P-value <0.05 was considered statistically significant. RESULTS cCTA was successfully performed in all patients. In a segment-based model, group 1 compared with group 2 showed a lower rate of overall artifacts (67% vs. 83%; P<0.001) and motion artifacts (49% vs. 66%; P<0.001), resulting in a better Likert image quality score (2.83±1.03 vs. 2.37±1.02; P<0.01) and overall evaluability (85% vs. 75%; P<0.01). Group 1 showed a lower ED as compared with group 2 (3.1±1.9 vs. 11.9±3.3 mSv; P<0.01). CONCLUSION MCA and cCTA with prospective ECG-triggering acquisition in patients with high HR improves image quality and overall evaluability compared with cCTA with standard retrospective ECG triggering.
Collapse
|
15
|
High-Pitch Coronary Computed Tomographic Angiography Using the Third-Generation Dual-Source Computed Tomography. J Comput Assist Tomogr 2018; 42:248-255. [DOI: 10.1097/rct.0000000000000678] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
16
|
Maroules CD, Hamilton-Craig C, Branch K, Lee J, Cury RC, Maurovich-Horvat P, Rubinshtein R, Thomas D, Williams M, Guo Y, Cury RC. Coronary artery disease reporting and data system (CAD-RADS TM): Inter-observer agreement for assessment categories and modifiers. J Cardiovasc Comput Tomogr 2017; 12:125-130. [PMID: 29217341 DOI: 10.1016/j.jcct.2017.11.014] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Revised: 09/21/2017] [Accepted: 11/30/2017] [Indexed: 12/27/2022]
Abstract
BACKGROUND The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. OBJECTIVES To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. METHODS Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and <4 designating moderate/low image quality. All readers were blinded to medical history and invasive coronary angiography findings. Inter-observer agreement for CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. RESULTS Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p < 0.0001). Agreement among expert readers (ICC 0.925, 95% CI 0.884-0.954) was marginally stronger than for early career readers (ICC 0.904, 95% CI 0.852-0.941), both p < 0.0001. High image quality was associated with stronger agreement than moderate image quality (ICC 0.944, 95% CI 0.886-0.974 vs. ICC 0.887, 95% CI 0.775-0.95, both p < 0.0001). While excellent inter-observer agreement was observed for modifiers S (stent) and G (bypass graft) (both κ = 1.0), only fair agreement (κ = 0.40) was observed for modifier V (high risk plaque). CONCLUSION Inter-observer reproducibility of CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation.
Collapse
Affiliation(s)
- Christopher D Maroules
- Department of Radiology, Naval Medical Center, Portsmouth, VA, United States; Miami Cardiac and Vascular Institute, Baptist Health South Florida, Miami, FL, United States.
| | | | - Kelley Branch
- Department of Cardiology, University of Washington, Seattle, WA, United States
| | - James Lee
- Henry Ford Health System, Department of Medicine, Division of Cardiology, Center for Structural Heart Disease, United States.
| | | | | | | | - Dustin Thomas
- Brooke Army Medical Center, San Antonio, TX, United States
| | | | - Yanshu Guo
- Department of Cardiology, University of Washington, Seattle, WA, United States
| | - Ricardo C Cury
- Miami Cardiac and Vascular Institute, Baptist Health South Florida, Miami, FL, United States
| |
Collapse
|
17
|
Ippolito D, Fior D, Franzesi CT, Riva L, Casiraghi A, Sironi S. Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality. LA RADIOLOGIA MEDICA 2017; 122:893-901. [PMID: 28849537 DOI: 10.1007/s11547-017-0800-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Accepted: 08/10/2017] [Indexed: 02/05/2023]
Abstract
BACKGROUND Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. OBJECTIVES To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. METHODS Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose4; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. RESULTS Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. CONCLUSIONS The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.
Collapse
Affiliation(s)
- Davide Ippolito
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy.
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy.
| | - Davide Fior
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Cammillo Talei Franzesi
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Luca Riva
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Alessandra Casiraghi
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Sandro Sironi
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
- Department of Diagnostic Radiology, "Papa Giovanni XXIII" Hospital, Bergamo, Italy
| |
Collapse
|
18
|
Reduction of Coronary Motion Artifacts in Prospectively Electrocardiography-Gated Coronary Computed Tomography Angiography Using Monochromatic Imaging at Various Energy Levels in Combination With a Motion Correction Algorithm on Single-Source Fast Tube Voltage Switching Dual-Energy Computed Tomography: A Phantom Experiment. Invest Radiol 2017; 51:513-9. [PMID: 27257865 DOI: 10.1097/rli.0000000000000263] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to assess the effect of monochromatic imaging at various energy levels in combination with a motion correction algorithm (MCA) in single-source dual-energy coronary computed tomography angiography (CCTA) with fast switching of tube voltage on the reduction of coronary motion artifacts (CMA) in a phantom setting. MATERIALS AND METHODS Using this dual-energy computed tomography technique with a phantom comprising models of coronary vessels filled with contrast medium and pulsating at constant heart rates of 60 to 100 beats per minute, we reconstructed monochromatic images of CCTA obtained at 50 to 90 keV with and without use of MCA. Cardiac motion was modeled by simulating the in vivo time-volume curve of the left ventricle. Two independent readers graded CMA in 9 coronary segments using a 5-point scale (1, poor; 3 to 5, interpretable; 5, excellent). At each heart rate, we compared the average score of CMA between images obtained at 50 to 90 keV with and without use of MCA using Wilcoxon signed rank test, and we compared the score among images obtained at 50 to 90 keV with use of MCA using Kruskal-Wallis and post hoc tests. We also compared the percentages of image interpretability and improvement in image interpretability among images obtained at 50 to 90 keV with use of MCA. RESULTS With the use of MCA, the average score of CMA was significantly higher for images obtained at each energy level from 50 to 70 keV (P < 0.05) and was comparable at 80 and 90 keV, and it was comparable among those obtained at 50 to 70 keV. With its use, the percentages of image interpretability were similarly high at 50 to 70 keV at 60 to 80 beats per minute (78%-100%), and they were higher at 50 to 60 keV (72%-83%) than at 70 keV at 90 to 100 beats per minute (50%-56%). The percentages of improved image interpretability with MCA were similarly high at 50 to 70 keV at 60 to 80 beats per minute (56%-100%), and they were higher at 50 to 60 keV (62%-77%) than at 70 keV at 90 to 100 beats per minute (36%-43%). The percentages of image interpretability and improved image interpretability with MCA were insufficient at 80 and 90 keV. CONCLUSIONS Coronary motion artifacts were significantly reduced in images of monochromatic CCTA obtained at 50 to 70 keV in combination with MCA compared with those obtained without MCA, and the percentages of image interpretability and improved image interpretability with use of MCA were relatively high at 50 to 70 keV, and particularly at 50 to 60 keV, even at 90 to 100 beats per minute.
Collapse
|
19
|
Feasibility of a single-beat prospective ECG-gated cardiac CT for comprehensive evaluation of aortic valve disease using a 256-detector row wide-volume CT scanner: an initial experience. Int J Cardiovasc Imaging 2017; 34:293-300. [DOI: 10.1007/s10554-017-1223-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 07/31/2017] [Indexed: 12/14/2022]
|
20
|
Yu M, Zhang Y, Li Y, Li M, Li W, Zhang J. Assessment of Myocardial Bridge by Cardiac CT: Intracoronary Transluminal Attenuation Gradient Derived from Diastolic Phase Predicts Systolic Compression. Korean J Radiol 2017; 18:655-663. [PMID: 28670160 PMCID: PMC5447641 DOI: 10.3348/kjr.2017.18.4.655] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 01/25/2017] [Indexed: 12/13/2022] Open
Abstract
Objective To study the predictive value of transluminal attenuation gradient (TAG) derived from diastolic phase of coronary computed tomography angiography (CCTA) for identifying systolic compression of myocardial bridge (MB). Materials and Methods Consecutive patients diagnosed with MB based on CCTA findings and without obstructive coronary artery disease were retrospectively enrolled. In total, 143 patients with 144 MBs were included in the study. Patients were classified into three groups: without systolic compression, with systolic compression < 50%, and with systolic compression ≥ 50%. TAG was defined as the linear regression coefficient between intraluminal attenuation in Hounsfield units (HU) and length from the vessel ostium. Other indices such as the length and depth of the MB were also recorded. Results TAG was the lowest in MB patients with systolic compression ≥ 50% (-19.9 ± 8.7 HU/10 mm). Receiver operating characteristic curve analysis was performed to determine the optimal cutoff values for identifying systolic compression ≥ 50%. The result indicated an optimal cutoff value of TAG as -18.8 HU/10 mm (area under curve = 0.778, p < 0.001), which yielded higher sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy (54.1, 80.5, 72.8, and 75.0%, respectively). In addition, the TAG of MB with diastolic compression was significantly lower than the TAG of MB without diastolic compression (-21.4 ± 4.8 HU/10 mm vs. -12.7 ± 8 HU/10 mm, p < 0.001). Conclusion TAG was a better predictor of MB with systolic compression ≥ 50%, compared to the length or depth of the MB. The TAG of MB with persistent diastolic compression was significantly lower than the TAG without diastolic compression.
Collapse
Affiliation(s)
- Mengmeng Yu
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Yang Zhang
- Department of Pharmaceutical Science, School of Pharmacy, The Second Military Medical University, Shanghai 200433, China.,Department of Scientific Research, TongRen Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200050, China
| | - Yuehua Li
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Minghua Li
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Wenbin Li
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Jiayin Zhang
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| |
Collapse
|
21
|
Chian TC, Nassir NM, Ibrahim MI, Yusof AKM, Sabarudin A. Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings. Quant Imaging Med Surg 2017; 7:48-58. [PMID: 28275559 DOI: 10.21037/qims.2017.02.02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. METHODS Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. RESULTS Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. CONCLUSIONS There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.
Collapse
Affiliation(s)
- Teo Chee Chian
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | - Norziana Mat Nassir
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | - Mohd Izuan Ibrahim
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | | | - Akmal Sabarudin
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| |
Collapse
|
22
|
Tang PH, Du BJ, Fang XM, Hu XY, Qian PY, Gao QS. Submillisievert coronary CT angiography with adaptive prospective ECG-triggered sequence acquisition and iterative reconstruction in patients with high heart rate on the dual-source CT. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2016; 24:807-820. [PMID: 27612046 DOI: 10.3233/xst-160589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE To assess the application value of submillisievert coronary CT angiography (CCTA) in patients with a high heart rate (HR) acquired with adaptive prospective ECG-triggered sequence acquisition and iterative reconstruction on the secondary generation dual-source CT. MATERIALS AND METHODS A total of 120 consecutive high-HR patients suspected with coronary artery disease underwent CCTA and invasive coronary angiography (ICA) within two weeks. Patients were randomly assigned into three groups: group A (n = 40), where the patients underwent retrospectively ECG-triggered acquisition CCTA at 100 kVp; group B (n = 40), where the patients received adaptive prospective ECG-triggered sequence acquisition at 100 kVp; and group C (n = 40), where the patients performed adaptive prospective ECG-triggered sequence acquisition at 80 kVp with iterative reconstruction. The mean CT values, signal noise ratios (SNR) and contrast noise ratios (CNR) in the ascending aorta and coronary arteries of the three groups were measured and compared. The image quality and radiation dose among the three groups were compared. The consistency of displaying the coronary stenosis of each group was assessed compared with the results of ICA as the gold standard. RESULTS There was no significant difference in gender, age and body mass index (BMI) (all P > 0.05). The mean attenuations, SNRs and CNRs in the ascending aorta and coronary artery were not significantly different between group A and group B (P > 0.05). The mean attenuations of group C were significantly higher than group A and group B (P < 0.01), but the image noise and CNR were significantly lower in group C (P < 0.01). The number of appreciable segments among the three groups was not significantly different on a per-segment and per-vessel basis (P > 0.05). The subjective image quality among the three groups was not significantly different (P > 0.05). With the ICA result as a reference standard, there was good consistency in the evaluation of the coronary stenosis degree between CCTA and ICA (r > 0.75), as well as in the assessment of the coronary stenosis rate using the Bland- Altman analysis. The mean radiation dose in group B was half of that in group A. Moreover, the mean radiation dose in group C was less than one sixth of that in group A and less than 1 mSv (0.7±0.2 mSv). CONCLUSIONS For patients with high HR, adaptive prospective ECG-triggered sequence acquisition on the FLASH dual-source CT results in equal image quality and half of the radiation dose reduction compared with retrospectively ECG-triggered spiral acquisition at the same tube voltage (100 kVp) and same R-R interval of exposure. In addition, adaptive prospective ECG-triggered sequence acquisition combined with low tube voltage and iterative reconstruction can further reduce the radiation dose to the submillisievert level without compromising image quality and the accuracy of assessing the coronary stenosis degree, and can be popularized as a routine technique.
Collapse
Affiliation(s)
- Pei-Hua Tang
- Department of Radiology, Department of Electrocardiogram, Wuxi No.4 People's Hospital, Binghu District, Wuxi, China
| | - Ben-Jun Du
- Department of Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Xiang-Ming Fang
- Department of Radiology, Wuxi People's Hospital, Nanjing Medical University, Nanchang District, Wuxi, China
| | - Xiao-Yun Hu
- Department of Radiology, Wuxi People's Hospital, Nanjing Medical University, Nanchang District, Wuxi, China
| | - Ping-Yan Qian
- Department of Radiology, Wuxi People's Hospital, Nanjing Medical University, Nanchang District, Wuxi, China
| | - Quan-Sheng Gao
- Laboratory of the Animal Center, Academy of Military Medical Sciences, Haidian District, Beijing, China
| |
Collapse
|
23
|
Long B, Koyfman A. Best Clinical Practice: Current Controversies in Evaluation of Low-Risk Chest Pain-Part 1. J Emerg Med 2016; 51:668-676. [PMID: 27693075 DOI: 10.1016/j.jemermed.2016.07.103] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2015] [Revised: 07/20/2016] [Accepted: 07/21/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND Chest pain is a common presentation to the emergency department (ED), though the majority of patients are not diagnosed with acute coronary syndrome (ACS). Many patients are admitted to the hospital due to fear of ACS. OBJECTIVE Our aim was to investigate controversies in low-risk chest pain evaluation, including risk of missed ACS, stress test, and coronary computed tomography angiography (CCTA). DISCUSSION Chest pain accounts for 10 million ED visits in the United States annually. Many patients are at low risk for a major cardiac adverse event (MACE). With negative troponin and nonischemic electrocardiogram (ECG), the risk of MACE and myocardial infarction (MI) is < 1%. The American Heart Association recommends further evaluation in low- to intermediate-risk patients within 72 h. These modalities add little to further risk stratification. These evaluations do not appropriately risk stratify patients who are already at low risk, nor do they diagnose acute MI. CCTA is an anatomic evaluation of the coronary vasculature with literature support to decrease ED length of stay, though it is associated with downstream testing. Literature is controversial concerning further risk stratification in already low-risk patients. CONCLUSIONS With nonischemic ECG and negative cardiac biomarker, the risk of ACS approaches < 1%. Use of stress test and CCTA for risk stratification of low-risk chest pain patients is controversial. These tests may allow prognostication but do not predict ACS risk beyond ECG and troponin. CCTA may be useful for intermediate-risk patients, though further studies are required.
Collapse
Affiliation(s)
- Brit Long
- Department of Emergency Medicine, San Antonio Military Medical Center, Fort Sam Houston, Texas
| | - Alex Koyfman
- The University of Texas Southwestern Medical Center, Department of Emergency Medicine, Dallas, Texas
| |
Collapse
|
24
|
Yamamoto H, Kihara Y. Lower Radiation Exposure Needs Lower Heart Rate. Circ J 2016; 80:1106-7. [PMID: 27052000 DOI: 10.1253/circj.cj-16-0281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Hideya Yamamoto
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | | |
Collapse
|
25
|
Individualized reduction of radiation dose with a chest circumference-adapted technique and iterative reconstructions in 256-slice retrospective and prospective ECG-triggered computed tomography coronary angiography. Coron Artery Dis 2016; 26:308-16. [PMID: 25714067 DOI: 10.1097/mca.0000000000000232] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess the impact of chest circumference (CC)-adjusted tube current and iterative reconstructions (iDose) on individualized radiation dose reduction and image quality (IQ) in ECG-triggered computed tomography coronary angiography (CTCA). MATERIALS AND METHODS A total of 102 patients underwent retrospectively ECG-triggered CTCA utilizing CC-adapted tube current [mAs=1000×(0.051×CC-23.765)/900] and filtered back projection (FBP) reconstruction (group A). On the basis of the CC-adjusted tube current technique, 54 patients (group B) underwent retrospective ECG-triggered CTCA with a 20% mAs reduction compared with group A and 90 patients (group C) underwent prospective ECG-triggered CTCA with an 80% mAs reduction compared with group A; both groups B and C were reconstructed with FBP and iDose. Subjective IQ was assessed, and image noise, signal-to-noise, and contrast-to-noise ratios (SNR and CNR) were quantified. RESULTS Patients in group A had the highest radiation dose, followed by group B and group C. iDose provided decreased image noise and increased SNR and CNR, as did subjective IQ. The image noise was higher and SNR and CNR in group B were obviously lower than those in group A with FBP, but in group B, iDose4 increased the mean objective IQ. There was no difference between group B with iDose and group A with FBP, as was the case with subjective IQ. CONCLUSION The combination of a CC-adapted technique, prospective triggering, and partial iterative reconstruction techniques reduces the radiation dose significantly, without significant degradation of IQ.
Collapse
|
26
|
alamir MA, Ellenberg SS, Swerdloff RS, Wenger NK, Mohler ER, Lewis CE, Barrett-Conner E, Nakanishi R, Darabian S, Alani A, Matsumoto S, Nezarat N, Snyder PJ, Budoff MJ. The Cardiovascular Trial of the Testosterone Trials: rationale, design, and baseline data of a clinical trial using computed tomographic imaging to assess the progression of coronary atherosclerosis. Coron Artery Dis 2016; 27:95-103. [PMID: 26554661 PMCID: PMC4738150 DOI: 10.1097/mca.0000000000000321] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Data from prior studies have yielded inconsistent results on the association of serum testosterone levels with the risk for cardiovascular disease. There are no clinical trial data on the effects of testosterone replacement therapy on plaque progression. OBJECTIVE We designed a study to investigate the effect of testosterone therapy on coronary artery plaque progression using serial coronary computed tomographic angiography (CCTA). In this paper, we describe the study design, methods, and characteristics of the study population. METHODS The Cardiovascular Trial of the Testosterone Trials (TTrials; NCT00799617) is a double-blind, placebo-controlled trial of 1 year of testosterone therapy in men 65 years or older with clinical manifestations of androgen deficiency and unequivocally low serum testosterone concentrations (<275 ng/dl). CCTA performed at baseline and after 12 months of therapy will determine the effects of testosterone on the progression of the total volume of noncalcified plaques. All scans are evaluated at a central reading center by an investigator blinded to treatment assignment. RESULTS A total of 165 men were enrolled. The average age is 71.1 years, and the average BMI is 30.7. About 9% of men had a history of myocardial infarction, 6% angina, and 10% coronary artery revascularization. A majority reported hypertension and/or high cholesterol; 31.8% reported diabetes. Total noncalcified plaque at baseline showed a slight but nonsignificant trend toward lower plaque volume with higher serum testosterone concentrations (P=0.12). CONCLUSION The Cardiovascular Trial will test the hypothesis that testosterone therapy inhibits coronary plaque progression, as assessed by serial CCTA.
Collapse
Affiliation(s)
- Moshrik Abd alamir
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| | - Susan S. Ellenberg
- Center for Clinical Epidemiology & Biostatistics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Ronald S. Swerdloff
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| | - Nanette K. Wenger
- Division of Cardiology, Department of Medicine, Emory University School of Medicine, Emory Heart and Vascular Center, Atlanta, GA, USA
| | - Emile R Mohler
- Division of Cardiovascular Disease and Section of Vascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Cora E. Lewis
- Division of Preventive Medicine, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Elizabeth Barrett-Conner
- Division of Epidemiology, Department of Family and Preventive Medicine, University of California San Diego, La Jolla, CA, USA
| | - Rine Nakanishi
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| | - Sirous Darabian
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| | - Anas Alani
- Cardiology Department, University of Florida, Gainesville, FL, USA
| | - Suguru Matsumoto
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| | - Negin Nezarat
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| | - Peter J. Snyder
- Division of Endocrinology, Diabetes, and Metabolism, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Matthew J. Budoff
- Los Angeles Biomedical Research Institute at Harbor-UCLA, Torrance, California, USA
| |
Collapse
|
27
|
Incremental prognostic value of computed tomography in stroke: rationale and design of the IMPACTS study. Int J Cardiovasc Imaging 2016; 32 Suppl 1:83-9. [PMID: 26910046 DOI: 10.1007/s10554-016-0860-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Accepted: 02/17/2016] [Indexed: 01/07/2023]
Abstract
This study was designed to determine the prognostic value of coronary computed tomography angiography (CCTA) in ischemic stroke patients and to identify any incremental risk stratification benefits of CCTA findings compared with coronary artery calcium scoring (CACS) and traditional Framingham risk scores (FRS) in ischemic stroke patients without chest pain. IMPACTS is a prospective, multicenter, observational cohort study in which at least seven centers in Korea will participate. All participants will be enrolled in this study after providing informed consent. Nine hundred total ischemic stroke patients without chest pain will be enrolled and will undergo CACS and CCTA. All participants will be followed-up for a minimum of 24 months to determine the endpoints. The primary endpoint will be occurrence of major adverse cardiovascular events (MACEs), defined as all-cause mortality, cardiovascular death, myocardial infarction, or cardiovascular events requiring hospitalization and revascularization either by percutaneous coronary intervention or by coronary artery bypass graft after 90 days of index testing during the follow-up period. Patient enrollment should be completed within 2.5 years. We plan to analyze and identify the CCTA predictors of MACEs. In addition, we will compare several models used to assess independent relationships between the variables and MACEs using a shared frailty model and therefore determine the incremental prognostic value of CCTA findings compared with either the CACS or FRS. The results of IMPACTS will provide valuable information for risk stratification with CCTA in ischemic stroke patients without chest pain.
Collapse
|
28
|
Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease. Int J Cardiovasc Imaging 2016; 32:991-8. [PMID: 26897005 DOI: 10.1007/s10554-016-0854-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2015] [Accepted: 02/08/2016] [Indexed: 10/22/2022]
Abstract
To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p < 0.001). The mean CNR and SD were 28.19 ± 13.00 and 15.75 ± 3.61HU, respectively. The image quality scores were 4.31 ± 0.36 and 4.29 ± 0.41 from reviewer 1 and 2 respectively with an excellent agreement between them (Kappa = 0.85). The detection rate for the origins of the left and right coronary arteries was 96 and 90 %, respectively. The detection rates of the origins of left coronary artery and right coronary artery in all cases were 96 % (78/81) and 90 % (73/81), respectively. Twenty cases of conotruncal anomalies and ALCAPA were validated surgically and the accuracy of cardiac CT diagnosis was 95 % (19/20). The overall deformity based sensitivity, specificity, positive predictive value and negative predictive value were 94.0.1, 99.9, 98.6, 99.5 % respectively, by CCT, and 88.2, 99.9, 97.8, 99.0 %, respectively, by echocardiography. Prospective ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.
Collapse
|
29
|
Raimondi F, Warin-Fresse K. Computed tomography imaging in children with congenital heart disease: Indications and radiation dose optimization. Arch Cardiovasc Dis 2016; 109:150-7. [PMID: 26782623 DOI: 10.1016/j.acvd.2015.11.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Revised: 11/16/2015] [Accepted: 11/18/2015] [Indexed: 11/24/2022]
Abstract
Computed tomography (CT) technology is acquiring a key role in the diagnostic process of complex cardiac congenital anomalies. Recent advances and improvements in spatial and temporal resolution and radiation dose are encouraging the use of CT scanning in children. Paediatric cardiologists should have a good knowledge of the potential of CT techniques and their limitations to plan and properly perform CT examinations without forgetting radiation concerns. In this paper, we will discuss the principal indications for CT scans in newborns and children in our clinical practice. We will also outline the most-used strategies for dose reduction. Basic knowledge about the various CT techniques is crucial, not only to perform, but also to interpret CT results, thus helping the medical and surgical management of patients.
Collapse
Affiliation(s)
- Francesca Raimondi
- Unité médicochirurgicale de cardiologie congénitale et pédiatrique, service de radiologie pédiatrique, centre de référence des maladies cardiaques congénitales complexes - M3C, hôpital universitaire Necker-Enfants-Malades, 149, rue de Sèvres, 75743 Paris cedex 15, France; Université Paris Descartes, Sorbonne Paris Cité, 15, rue de l'École-de-Médecine, 75006 Paris, France.
| | - Karine Warin-Fresse
- Imagerie cardiovasculaire, fédération des cardiopathies congénitales, CHU de Nantes, 44093 Nantes cedex 1, France
| |
Collapse
|
30
|
Fathala A. Coronary computed tomography angiography for risk stratification before noncardiac surgery. Ann Card Anaesth 2016; 19:31-7. [PMID: 26750671 PMCID: PMC4900383 DOI: 10.4103/0971-9784.173017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Currently, there are limited available data for coronary computed tomography angiography (CCTA) in the setting of the risk stratification before noncardiac surgery. The main purpose of this study is to investigate the role of CCTA in cardiac risk stratification before noncardiac surgery. MATERIALS AND METHODS Ninety-three patients underwent CCTA in the assessment of cardiac risk before noncardiac surgery. Patients with normal or mildly abnormal CCTA (<50% stenosis) underwent surgery without any further testing (Group 1). Patients with abnormal CCTA (17 patients) (more than 50% stenosis) and nondiagnostic CCTA (5%) underwent either stress myocardial perfusion scintigraphy or conventional coronary angiography, Group 2. RESULTS Group one consists of 71 patients who went for surgery without any further testing. 59 of 71 (83%) patients had no complications in the postoperative period, 9 patients had noncardiac complications, 1 had a cardiac complication (new onset atrial fibrillation), and 2 patients died in the postoperative period due to noncardiac complications. Group 2 comprises 22 (26%) patients, 16 patients had no postoperative complications, 5 patients had noncardiac complications, and one patient developed postoperative acute heart failure. CONCLUSIONS CCTA is diagnostic in up to 95% in the preoperative setting, and it provides a comprehensive cardiac examination in the risk stratification before intermediate and high-risk noncardiac surgery. Therefore, CCTA may be considered as an alternative test for already established imaging techniques for preoperative cardiac risk stratification before noncardiac surgery.
Collapse
Affiliation(s)
- Ahmed Fathala
- Cardiovascular Imaging and Nuclear Medicine, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia
| |
Collapse
|
31
|
Kido T, Mochizuki T, Hirano M, Yamada Y, Tanaka R, Kanzaki S, Higashi M, Jinzaki M, Yoshioka K, Kuribayashi S. Radiation-Dose-Lowering Effects of Landiolol Hydrochloride in Coronary Angiography Using Computed Tomography (DELIGHT) – A Prospective Multicenter Study –. Circ J 2016; 80:1225-31. [DOI: 10.1253/circj.cj-15-0962] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine
| | | | | | - Yoshitake Yamada
- Department of Diagnostic Radiology, Keio University School of Medicine
| | - Ryoichi Tanaka
- Department of Cardiovascular Radiology, Memorial Heart Center, Iwate Medical University
| | - Suzu Kanzaki
- Department of Radiology, National Cerebral and Cardiovascular Center
| | - Masahiro Higashi
- Department of Radiology, National Cerebral and Cardiovascular Center
| | - Masahiro Jinzaki
- Department of Diagnostic Radiology, Keio University School of Medicine
| | - Kunihiro Yoshioka
- Department of Cardiovascular Radiology, Memorial Heart Center, Iwate Medical University
| | | |
Collapse
|
32
|
Dual-source computed tomography for evaluating pulmonary artery in pediatric patients with cyanotic congenital heart disease: Comparison with transthoracic echocardiography. Eur J Radiol 2015; 85:187-192. [PMID: 26724664 DOI: 10.1016/j.ejrad.2015.11.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2015] [Revised: 10/08/2015] [Accepted: 11/02/2015] [Indexed: 02/05/2023]
Abstract
PURPOSE To evaluate the quantitative accuracy of dual-source computed tomography (DSCT) on measurements of pulmonary artery in pediatric patients with cyanotic congenital heart diseases (CCHDs) when compared with transthoracic echocardiography (TTE). METHODS Thirty-five patients (mean age: 27.88 ± 28.27 months) with CCHDs underwent DSCT and TTE for evaluating the diameter of the main pulmonary artery (MPA), right pulmonary artery (RPA), and left pulmonary artery (LPA). Surgical measurements were obtained and served as the reference standard. The agreement was tested by linear regression analysis, Pearson's correlation coefficient, and Bland-Altman analysis. The intra- and extracardiac malformations were also observed. RESULTS There was a markedly positive correlation between DSCT and surgical measurements of the MPA, RPA, and LPA (r=0.95-0.97; all p<0.001), although the overestimation of the measurements of MPA, RPA, and LPA (bias 0.15 ± 0.95, 0.31 ± 0.63 and 0.35 ± 0.68 mm, respectively) was observed. However, there was a moderate correlation between TTE and surgical measurements of MPA, RPA, and LPA (r=0.61-0.84; all p<0.001), and the underestimation of the measurements of MPA, RPA, and LPA (bias-1.20 ± 1.69, -1.80 ± 1.77, and -1.50 ± 2.30 mm, respectively) was observed. In addition, DSCT was more efficient in finding associated malformations than TTE (40/40 vs. 33/40). CONCLUSIONS As a reliable, noninvasive and radiation-save imaging modality, DSCT can provide more accurate pulmonary artery measurements than TTE in cardiac surgical procedures.
Collapse
|
33
|
Habib Geryes B, Calmon R, Khraiche D, Boddaert N, Bonnet D, Raimondi F. Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality. Eur Radiol 2015; 26:2030-8. [PMID: 26433957 DOI: 10.1007/s00330-015-4032-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2015] [Revised: 09/07/2015] [Accepted: 09/15/2015] [Indexed: 01/13/2023]
Abstract
OBJECTIVES To assess the impact of different protocols on radiation dose and image quality for paediatric coronary computed tomography (cCT). MATERIALS AND METHODS From January-2012 to June-2014, 140 children who underwent cCT on a 64-slice scanner were included. Two consecutive changes in imaging protocols were performed: 1) the use of adaptive statistical iterative reconstruction (ASIR); 2) the optimization of acquisition parameters. Effective dose (ED) was calculated by conversion of the dose-length product. Image quality was assessed as excellent, good or with significant artefacts. RESULTS Patients were divided in three age groups: 0-4, 5-7 and 8-18 years. The use of ASIR combined to the adjustment of scan settings allowed a reduction in the median ED of 58 %, 82 % and 85 % in 0-4, 5-7 and 8-18 years group, respectively (7.3 ± 1.4 vs 3.1 ± 0.7 mSv, 5.5 ± 1.6 vs 1 ± 1.9 mSv and 5.3 ± 5.0 vs 0.8 ± 2.0 mSv, all p < 0,05). Prospective protocol was used in 51 % of children. The reduction in radiation dose was not associated with reduction in diagnostic image quality as assessed by the frequency of coronary segments with excellent or good image quality (88 %). CONCLUSIONS cCT can be obtained at very low radiation doses in children using ASIR, and prospective acquisition with optimized imaging parameters. KEY POINTS • Using ASIR allows 25 % to 41 % reduction in the ED. • Prospective protocol is used up to 51 % of children after premedication. • Low dose is possible using ASIR and optimized prospective paediatric cCT.
Collapse
Affiliation(s)
- Bouchra Habib Geryes
- Direction de la qualité et de la gestion des risques, Hôpital Universitaire Necker Enfants Malades, 149, rue de Sèvres, 75743, Paris Cedex 15, France
| | - Raphael Calmon
- Service de Radiologie pédiatrique, Hôpital Universitaire Necker Enfants Malades, 149, rue de Sèvres, 75743, Paris Cedex 15, France.,Sorbonne Paris Cité, Université Paris Descartes, Paris, France
| | - Diala Khraiche
- Unité Médico-Chirurgicale de Cardiologie Congénitale et Pédiatrique, Centre de référence Malformations Cardiaques Congénitales Complexes - M3C, 149, rue de Sèvres, 75743, Paris Cedex 15, France.,Sorbonne Paris Cité, Université Paris Descartes, Paris, France
| | - Nathalie Boddaert
- Service de Radiologie pédiatrique, Hôpital Universitaire Necker Enfants Malades, 149, rue de Sèvres, 75743, Paris Cedex 15, France.,Sorbonne Paris Cité, Université Paris Descartes, Paris, France
| | - Damien Bonnet
- Unité Médico-Chirurgicale de Cardiologie Congénitale et Pédiatrique, Centre de référence Malformations Cardiaques Congénitales Complexes - M3C, 149, rue de Sèvres, 75743, Paris Cedex 15, France.,Sorbonne Paris Cité, Université Paris Descartes, Paris, France
| | - Francesca Raimondi
- Service de Radiologie pédiatrique, Hôpital Universitaire Necker Enfants Malades, 149, rue de Sèvres, 75743, Paris Cedex 15, France. .,Unité Médico-Chirurgicale de Cardiologie Congénitale et Pédiatrique, Centre de référence Malformations Cardiaques Congénitales Complexes - M3C, 149, rue de Sèvres, 75743, Paris Cedex 15, France. .,Sorbonne Paris Cité, Université Paris Descartes, Paris, France.
| |
Collapse
|
34
|
Li FP, Rajchl M, White JA, Goela A, Peters TM. Ultrasound guidance for beating heart mitral valve repair augmented by synthetic dynamic CT. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:2025-2035. [PMID: 25775487 DOI: 10.1109/tmi.2015.2412465] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Minimally invasive valvular intervention commonly requires intra-procedural navigation to provide spatial and temporal information of relevant cardiac structures and device components. Recently intra-procedural trans-esophageal echocardiography (TEE) has been exploited for this purpose due to its accessibility, low cost, ease of use, and real-time imaging capacity. However, the position and orientation of tissue targets relative to surgical tools can be challenging to perceive, particularly using 2D imaging planes. In this paper, we propose the use of CT images to provide a high-quality 3D context to enhance ultrasound images through image registration, providing an augmented guidance system with minimal impact on standard clinical workflow. We also describe an approach to generate synthetic 4D CT images through non-rigid registration of available ultrasound. This can be employed to avoid a requirement for higher radiation. Synthetic CT images were validated through direct comparison of synthetic and real multi-phase CT images. Validation of CT and ultrasound image registration was performed for both dynamic and synthetic CT image datasets. Our results demonstrated that the synthetically generated dynamic CT images provide similar anatomical representation for relevant cardiac anatomy relative to real dynamic CT images, and similar high registration accuracy that can be achieved for intra-procedural TEE to this versus real dynamic CT images.
Collapse
|
35
|
Coronary calcium scoring from contrast coronary CT angiography using a semiautomated standardized method. J Cardiovasc Comput Tomogr 2015; 9:446-53. [DOI: 10.1016/j.jcct.2015.06.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 05/21/2015] [Accepted: 06/02/2015] [Indexed: 11/20/2022]
|
36
|
Shi K, Yang ZG, Chen J, Zhang G, Xu HY, Guo YK. Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography. PLoS One 2015; 10:e0130987. [PMID: 26115034 PMCID: PMC4482600 DOI: 10.1371/journal.pone.0130987] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 05/26/2015] [Indexed: 02/05/2023] Open
Abstract
Purpose To evaluate the feasibility and diagnostic accuracy of retrospective electrocardiographically (ECG)-gated dual-source computed tomography (DSCT) for the assessment of double outlet right ventricle (DORV) and associated multiple malformations in pediatric patients. Materials and Methods Forty-seven patients <10 years of age with DORV underwent retrospective ECG-gated DSCT. The location of the ventricular septal defect (VSD), alignment of the two great arteries, and associated malformations were assessed. The feasibility of retrospective ECG-gated DSCT in pediatric patients was assessed, the image quality of DSCT and the agreement of the diagnosis of associated malformations between DSCT and transthoracic echocardiography (TTE) were evaluated, the diagnostic accuracies of DSCT and TTE were referred to surgical results, and the effective doses were calculated. Results Apart from DORV, 109 associated malformations were confirmed postoperatively. There was excellent agreement (κ = 0.90) for the diagnosis of associated malformations between DSCT and TTE. However, DSCT was superior to TTE in demonstrating paracardiac anomalies (sensitivity, coronary artery anomalies: 100% vs. 80.00%, anomalies of great vessels: 100% vs. 88.57%, separate thoracic and abdominal anomalies: 100% vs. 76.92%, respectively). Combined with TTE, DSCT can achieve excellent diagnostic performance in intracardiac anomalies (sensitivity, 91.30% vs. 100%). The mean image quality score was 3.70 ± 0.46 (κ = 0.76). The estimated mean effective dose was < 1 mSv (0.88 ± 0.34 mSv). Conclusions Retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus expose the patients to a much lower radiation dose.
Collapse
Affiliation(s)
- Ke Shi
- Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China
| | - Zhi-gang Yang
- Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China
- National Key Laboratory of Biotherapy, West China Hospital, Sichuan University, 17# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China
- * E-mail: (ZGY); (YKG)
| | - Jing Chen
- Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China
| | - Ge Zhang
- Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China
| | - Hua-yan Xu
- Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China
- National Key Laboratory of Biotherapy, West China Hospital, Sichuan University, 17# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China
| | - Ying-kun Guo
- Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China
- * E-mail: (ZGY); (YKG)
| |
Collapse
|
37
|
Qahtani SA, Kandeel AY, Breault S, Jouannic AM, Qanadli SD. Prevalence of Acute Coronary Syndrome in Patients Suspected for Pulmonary Embolism or Acute Aortic Syndrome: Rationale for the Triple Rule-Out Concept. J Clin Med Res 2015; 7:627-31. [PMID: 26124909 PMCID: PMC4471750 DOI: 10.14740/jocmr2197w] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/08/2015] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND The aims of the study were to evaluate the prevalence of acute coronary syndrome (ACS) among patients presenting with atypical chest pain who are evaluated for acute aortic syndrome (AAS) or pulmonary embolism (PE) with computed tomoangiography (CTA) and discuss the rationale for the use of triple rule-out (TRO) protocol for triaging these patients. METHODS This study is a retrospective analysis of patients presenting with atypical chest pain and evaluated with thoracic (CTA), for suspicion of AAS/PE. Two physicians reviewed patient files for demographic characteristics, initial CT and final clinical diagnosis. Patients were classified according to CTA finding into AAS, PE and other diagnoses and according to final clinical diagnosis into AAS, PE, ACS and other diagnoses. RESULTS Four hundred and sixty-seven patients were evaluated: 396 (84.8%) patients for clinical suspicion of PE and 71 (15.2%) patients for suspicion of AAS. The prevalence of ACS and AAS was low among the PE patients: 5.5% and 0.5% respectively (P = 0.0001), while the prevalence of ACS and PE was 18.3% and 5.6% among AAS patients (P = 0.14 and P = 0.34 respectively). CONCLUSION The prevalence of ACS and AAS among patients suspected clinically of having PE is limited while the prevalence of ACS and PE among patients suspected clinically of having AAS is significant. Accordingly patients suspected for PE could be evaluated with dedicated PE CTA while those suspected for AAS should still be triaged using TRO protocol.
Collapse
Affiliation(s)
- Saad Al Qahtani
- Department of Radiology & Medical Imaging, Armed Forces Hospital, Southern Region, Saudi Arabia
| | - Ahmed Y Kandeel
- Department of Radiology & Medical Imaging, Armed Forces Hospital, Southern Region, Saudi Arabia
| | - Stephane Breault
- Cardio-Thoracic and Vascular Unit, Department of Radiology, University Hospital of Lausanne, Switzerland
| | - Anne-Marie Jouannic
- Cardio-Thoracic and Vascular Unit, Department of Radiology, University Hospital of Lausanne, Switzerland ; Quantitative Medical Imaging Laboratory, Department of Radiology, University Hospital of Lausanne, Switzerland
| | - Salah D Qanadli
- Cardio-Thoracic and Vascular Unit, Department of Radiology, University Hospital of Lausanne, Switzerland ; Quantitative Medical Imaging Laboratory, Department of Radiology, University Hospital of Lausanne, Switzerland
| |
Collapse
|
38
|
Machida H, Tanaka I, Fukui R, Shen Y, Ishikawa T, Tate E, Ueno E. Current and Novel Imaging Techniques in Coronary CT. Radiographics 2015; 35:991-1010. [PMID: 26046942 DOI: 10.1148/rg.2015140181] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Multidetector coronary computed tomography (CT), which is widely performed to assess coronary artery disease noninvasively and accurately, provides excellent image quality. Use of electrocardiography (ECG)-controlled tube current modulation and low tube voltage can reduce patient exposure to nephrotoxic contrast media and carcinogenic radiation when using standard coronary CT with a retrospective ECG-gated helical scan. Various imaging techniques are expected to overcome the limitations of standard coronary CT, which also include insufficient spatial and temporal resolution, beam-hardening artifacts, limited coronary plaque characterization, and an inability to allow functional assessment of coronary stenosis. Use of a step-and-shoot scan, iterative reconstruction, and a high-pitch dual-source helical scan can further reduce radiation dose. Dual-energy CT can improve contrast medium enhancement and reasonably reduce the contrast dose when combined with noise reduction with the use of iterative reconstruction. High-definition CT can improve spatial resolution and diagnostic evaluation of small or peripheral coronary vessels and coronary stents. Dual-source CT and a motion correction algorithm can improve temporal resolution and reduce coronary motion artifacts. Whole-heart coverage with 320-detector CT and an intelligent boundary registration algorithm can eliminate stair-step artifacts. By decreasing beam hardening and enabling material decomposition, dual-energy CT is expected to remove or reduce the depiction of coronary calcification to improve intraluminal evaluation of calcified vessels and to provide detailed analysis of coronary plaque components and accurate qualitative and quantitative assessment of myocardial perfusion. Fractional flow reserve derived from coronary CT is a state-of-the-art noninvasive technique for accurately identifying myocardial ischemia beyond coronary CT. Understanding these techniques is important to enhance the value of coronary CT for assessment of coronary artery disease.
Collapse
Affiliation(s)
- Haruhiko Machida
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| | - Isao Tanaka
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| | - Rika Fukui
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| | - Yun Shen
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| | - Takuya Ishikawa
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| | - Etsuko Tate
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| | - Eiko Ueno
- From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., I.T., R.F., Y.S., T.I., E.T., E.U.); and GE Healthcare, Tokyo, Japan (Y.S.)
| |
Collapse
|
39
|
Stefanini GG, Windecker S. Can coronary computed tomography angiography replace invasive angiography? Coronary computed tomography angiography cannot replace invasive angiography. Circulation 2015; 131:418-25; discussion 426. [PMID: 25623124 DOI: 10.1161/circulationaha.114.008148] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
40
|
Huang W, Xu Y, Lu D, Shi Y, Lu G. Single- versus multi-phase acquisition protocol for prospective-triggered sequential dual-source CT coronary angiography: comparison of image quality and radiation dose. Clin Imaging 2015; 39:597-602. [PMID: 25825344 DOI: 10.1016/j.clinimag.2015.02.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2014] [Revised: 02/17/2015] [Accepted: 02/24/2015] [Indexed: 01/07/2023]
Abstract
OBJECTIVE To investigate image quality and radiation dose of single- versus multi-phase acquisition protocol for prospective-triggered sequential dual-source computed tomography (CT) coronary angiography. MATERIALS AND METHODS A total of 140 patients were randomly assigned to single- or multi-phase group. Image quality and radiation dose were compared. RESULTS No significant difference was found in image quality between the two groups. Effective dose of single-phase group was 21.6% lower than that of multi-phase group (P<.001). CONCLUSIONS Prospective-triggered sequential dual-source CT coronary angiography using single-phase protocol can reduce radiation dose without sacrifice of image quality in diastole compared with multi-phase protocol.
Collapse
Affiliation(s)
- Wei Huang
- Department of Medical Imaging, Nanjing Jinling Hospital, Southern Medical University (Guangzhou), 305# Eastern Zhongshan Road, Nanjing 210002, China; Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China.
| | - Yiming Xu
- Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China
| | - Daoyan Lu
- Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China
| | - Yuzhen Shi
- Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China
| | - Guangming Lu
- Department of Medical Imaging, Nanjing Jinling Hospital, Southern Medical University (Guangzhou), 305# Eastern Zhongshan Road, Nanjing 210002, China.
| |
Collapse
|
41
|
Mafalanka F, Etard C, Rehel JL, Pesenti-Rossi D, Amrar-Vennier F, Baron N, Christiaens L, Convers-Domart R, Defez D, Douek P, Gaxotte V, Georges JL, Leygnac S, Ou P, Sablayrolles JL, Salvat C, Schouman-Claeys E, Sirol M, Aubert B. Establishment of diagnostic reference levels in cardiac CT in France: a need for patient dose optimisation. RADIATION PROTECTION DOSIMETRY 2015; 164:116-119. [PMID: 25342609 DOI: 10.1093/rpd/ncu317] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation dose, and the lack of European recommendations. Volume Computed Tomography Dose Index (CTDIvol) and dose-length product (DLP) were collected from 460 CCTAs performed over a 3-month period at eight French hospitals. CCTAs (∼50 per centre) were performed using the routine protocols of the centres, and 64- to 320-detector CT scanners. ECG gating was prospective (n = 199) or retrospective (n = 261). The large gap in dose between these two modes required to propose specific DRLs: 26 and 44 mGy for CTDIvol, and 370 and 970 mGy cm for DLP, respectively. This study confirms the large variability in patient doses during CCTA and underlines the need for the optimisation of cardiac acquisition protocols. Availability of national DRLs should be mandatory in this setting.
Collapse
Affiliation(s)
- F Mafalanka
- Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France
| | - C Etard
- Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France
| | - J L Rehel
- Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France
| | | | | | - N Baron
- Hôpital Mignot, Le Chesnay, France
| | | | | | - D Defez
- Centre Hospitalier Universitaire, Lyon, France
| | - P Douek
- Centre Hospitalier Universitaire, Lyon, France
| | - V Gaxotte
- Hôpital Bichat, AP-HP, Paris, France
| | | | - S Leygnac
- Hôpital Bichat, AP-HP, Paris, France
| | - P Ou
- Hôpital Bichat, AP-HP, Paris, France
| | | | - C Salvat
- Hôpital Lariboisière, AP-HP, Paris, France
| | | | - M Sirol
- Hôpital Lariboisière, AP-HP, Paris, France
| | - B Aubert
- Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France
| |
Collapse
|
42
|
Coronary computed tomographic angiography in coronary artery bypass grafts: comparison between low-concentration Iodixanol 270 and Iohexol 350. J Comput Assist Tomogr 2015; 39:112-8. [PMID: 25299799 DOI: 10.1097/rct.0000000000000162] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the feasibility of low-concentration iso-osmolar Iodixanol 270 compared with Iohexol 350 in patients with coronary artery bypass grafts (CABGs) undergoing coronary computed tomographic angiography (CCTA). METHODS A total of 80 consecutive patients undergoing CABG follow-up with the use of CCTA were prospectively enrolled, with 40 patients assigned to Iodixanol 270 and 40 patients assigned to Iohexol 350. In both groups, the contrast medium was injected at an injection rate of 4.5 mL/s in the patients with a body mass index of greater than 24 kg/m2 and 3.5 mL/s in the patients with a body mass index of 24 kg/m2 or lower. The contrast volume was determined by the flow rate and scan time. Image quality score and visualization of bypass grafts were evaluated. Subjective assessment of image quality for each coronary artery segment was determined using a 4-point grading scale by 2 reviewers, whereas objective evaluation of image quality was conducted by measuring the mean CT attenuation values (hounsfield unit [HU]) in terms of SD, contrast-noise ratio, and signal-noise ratio in the ascending aorta. RESULTS The mean (SD) contrast volume for the Iodixanol 270 and Iohexol 350 groups was 66.28 (12.00) and 64.98 (8.12) mL, respectively, with no significant difference (P = 0.57). The mean (SD) CT attenuation value in the Iodixanol 270 group was 414.72 (101.47), which was lower than in the Iohexol 350 group, which was 478.85 (108.73) (P = 0.01). The subjective image quality for the Iodixanol 270 group was superior to that for the Iohexol 350 group in the arterial graft vessels (P = 0.027), whereas there was no significant difference between the 2 groups in the venous graft vessels (P = 0.377). There was no significant difference in terms of SD of the ascending aorta, signal-noise ratio, and contrast-noise ratio between the 2 groups. CONCLUSIONS Low-concentration iso-osmolar Iodixanol 270 provides image quality comparable with that of Iohexol 350, allowing diagnostic CCTA follow-up of patients with CABGs.
Collapse
|
43
|
Abstract
During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.
Collapse
Affiliation(s)
- Albert de Roos
- From the Department of Radiology, Leiden University Medical Center, C2-S, Albinusdreef 2, Leiden, South-Holland 2333 ZA, the Netherlands (A.d.R); and Department of Radiology, University of California-San Francisco, San Francisco, Calif (C.B.H.)
| | | |
Collapse
|
44
|
Ünal E, Yıldız AE, Güler E, Karcaaltıncaba M, Akata D, Kılınçer A, Atlı E, Topçuoğlu M, Hazırolan T. Comparison of image quality and radiation dose between prospectively ECG-triggered and retrospectively ECG-gated CT angiography: Establishing heart rate cut-off values in first-generation dual-source CT. Anatol J Cardiol 2015; 15:759-64. [PMID: 25592108 PMCID: PMC5368488 DOI: 10.5152/akd.2014.5720] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Objective: To evaluate radiation dose and image quality of prospectively electrocardiography (ECG)-triggered and retrospectively ECG-gated coronary computed tomography (CT) angiography and to establish cut-off values of heart rates (HRs) for each technique in firstgeneration dual-source CT. Methods: A total of 200 consecutive patients with suspected coronary artery disease were accepted into the study. Patients were selected randomly for each technique (prospective triggering group n=99, mean age 55.85±10.74 and retrospective gating group n=101, mean age 53.38±11.58). Two independent radiologists scored coronary artery segments for image quality using a 5-point scale. Also, attenuation values of each coronary artery segment and dose-length product values were measured. For each technique, cut-off HR values were determined for the best image quality. Results: Mean image quality scores and attenuation values were found to be higher in the prospective triggering group (p<0.05). Mean radiation dose was 73% lower for the prospective triggering group (p<0.01). The cut-off HR values for good image quality scores were ≤67 beats per minute (bpm) and ≤80 bpm for the prospective triggering and retrospective gating groups, respectively (p<0.05). Increased HR (≥68 and ≥81 bpm, respectively) had negative effects on image quality (p<0.05). Conclusion: The prospective ECG triggering technique has better image quality scores than retrospective ECG gating, particularly in patients who have an HR of less than 68 bpm. Also, a 73% radiation dose reduction can be achieved with prospective ECG triggering. In patients with higher heart rates, retrospective ECG gating is recommended.
Collapse
Affiliation(s)
- Emre Ünal
- Department of Radiology, Faculty of Medicine, Hacettepe University; Ankara-Turkey.
| | | | | | | | | | | | | | | | | |
Collapse
|
45
|
CTCA Image Quality Improvement by Using Snapshot Freeze Technique Under Prospective and Retrospective Electrocardiographic Gating. J Comput Assist Tomogr 2015; 39:202-6. [DOI: 10.1097/rct.0000000000000193] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
46
|
Assessment of Single-Bolus Contrast Administration Technique Using Hybrid Dual-Source ECG-Gated Thoracic and Dual-Source Non–ECG-Gated High-Pitch Abdominopelvic CT Acquisitions for Procedural Planning Before Transcatheter Aortic Valve Replacement. J Comput Assist Tomogr 2015; 39:207-12. [DOI: 10.1097/rct.0000000000000194] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
47
|
Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate. Jpn J Radiol 2014; 33:84-93. [DOI: 10.1007/s11604-014-0382-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Accepted: 12/03/2014] [Indexed: 11/26/2022]
|
48
|
Li Q, Li P, Su Z, Yao X, Wang Y, Wang C, Du X, Li K. Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analyses. Eur J Radiol 2014; 83:2024-32. [DOI: 10.1016/j.ejrad.2014.08.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 07/11/2014] [Accepted: 08/04/2014] [Indexed: 10/24/2022]
|
49
|
Effect of iDose4 iterative reconstruction algorithm on image quality and radiation exposure in prospective and retrospective electrocardiographically gated coronary computed tomographic angiography. J Comput Assist Tomogr 2014; 38:956-62. [PMID: 25119063 DOI: 10.1097/rct.0000000000000137] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aims of this study were to compare a commercially available reconstruction algorithm (iDose4) with filtered back projection (FBP) in terms of image quality (IQ) for both retrospective electrocardiographically gated and prospective electrocardiographically triggered cardiac computed tomographic angiography (CCTA) protocols and to evaluate the achievable radiation dose reduction. METHODS A total cohort of 58 patients underwent either prospective CTCA or retrospective CTCA with full or reduced tube current-time product (in milliampere-second) protocol on a 64-slice multidetector computed tomographic scanner. All images were reconstructed with FBP, whereas the reduced milliampere-second images were also reconstructed using 2 levels (levels 4 and 6) of iDose4. Subjective and objective IQ was evaluated. RESULTS Dose reductions of 43% in the retrospective CCTA protocol and 27% in the prospective CCTA protocol were achieved without compromising IQ. In the prospective CCTA protocol, the reduced-dose images were highly scored; thus, additional reduction of exposure settings is feasible. In the retrospective acquisition, dose reduction has led to similar IQ scores between the reduced-dose iDose4 images and the full-dose FBP images. Considering different reconstructions (FBP, iDose-L4 and -L6) of the same acquisition data, increase in iDose4 level resulted in less noisy images. A slight improvement was also noticed in all IQ indices; however, this improvement was not statistically significant for both acquisition protocols. CONCLUSIONS This study demonstrated that the application of iDose at CCTA facilitates significant radiation dose reduction by maintaining diagnostic quality. The combination of iDose4 with prospective acquisition is able to significantly reduce effective dose associated with CTCA at values of approximately 2 mSv and even lower.
Collapse
|
50
|
A new technique for noise reduction at coronary CT angiography with multi-phase data-averaging and non-rigid image registration. Eur Radiol 2014; 25:41-8. [PMID: 25113650 DOI: 10.1007/s00330-014-3381-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2014] [Revised: 07/09/2014] [Accepted: 07/29/2014] [Indexed: 10/24/2022]
Abstract
OBJECTIVES To investigate the feasibility of a newly developed noise reduction technique at coronary CT angiography (CTA) that uses multi-phase data-averaging and non-rigid image registration. METHODS Sixty-five patients underwent coronary CTA with prospective ECG-triggering. The range of the phase window was set at 70-80% of the R-R interval. First, three sets of consecutive volume data at 70%, 75% and 80% of the R-R interval were prepared. Second, we applied non-rigid registration to align the 70% and 80% images to the 75% image. Finally, we performed weighted averaging of the three images and generated a de-noised image. The image noise and contrast-to-noise ratio (CNR) in the proximal coronary arteries between the conventional 75% and the de-noised images were compared. Two radiologists evaluated the image quality using a 5-point scale (1, poor; 5, excellent). RESULTS On de-noised images, mean image noise was significantly lower than on conventional 75% images (18.3 HU ± 2.6 vs. 23.0 HU ± 3.3, P < 0.01) and the CNR was significantly higher (P < 0.01). The mean image quality score for conventional 75% and de-noised images was 3.9 and 4.4, respectively (P < 0.01). CONCLUSIONS Our method reduces image noise and improves image quality at coronary CTA. KEY POINTS • We introduce a new method for image noise reduction at cardiac CT. • Multiple data acquisitions of an object and their averaging yield lower noise. • Our method uses multi-phase images reconstructed from unused redundant imaging data. • It reduces image noise by averaging multi-phase images transformed by non-rigid registration. • This method achieves a 20% image noise reduction at cardiac CT.
Collapse
|