1
|
Sun D, Lo KM, Chen SC, Leung WW, Wong C, Mak T, Ng S, Futaba K, Gregersen H. Consistency of Feces Affects Defecatory Function. J Neurogastroenterol Motil 2024; 30:373-378. [PMID: 38533644 PMCID: PMC11238102 DOI: 10.5056/jnm22177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 05/06/2023] [Accepted: 09/27/2023] [Indexed: 03/28/2024] Open
Abstract
Background/Aims It is a common belief that constipated patients have hard feces that contributes to the difficulties defecating. To the best of our knowledge, no studies had been published on controlled evacuation of simulated feces with different consistencies. Methods Twelve normal subjects were recruited for studies with the simulated feces device "Fecobionics" of different consistency (silicone shore 0A-40A corresponding to Bristol stool form scale types 2-4). The subjects filled out questionnaires and had the balloon expulsion test and anorectal manometry done for reference. The Fecobionics probes were inserted in rectum in random order with +20 minutes between insertions. The bag was filled to urge-to-defecate and evacuations took place in privacy. Non-parametric statistics with median and quartiles are provided. Results One subject was excluded due to technical issues, and another had abnormal anorectal manometry-balloon expulsion test. The 4 females/6 males subjects were aged 23 (range 20-48) years. Most differences were observed between the 0A and 10A probe (duration, maximum bag pressure, duration x maximum bag pressure, and relaxation of the front pressure and the bend angle during evacuation), eg, the duration was 9 (8-12) seconds at 0A and 18 (12-21) seconds at 10A (P < 0.05), and maximum bag pressure was 107 (96-116) cmH2O at 0A and 140 (117-162) cmH2O at 10A (P < 0.05). The bend angle before evacuation differed between the probes whereas only the 10A differed from 40A during defecation. The 10A was harder to evacuate than the 0A probe. Except for the bend angles, no further significant change was observed from 10A to 40A. Conclusion Fecal consistency affects defecatory parameters.
Collapse
Affiliation(s)
- Daming Sun
- Engineering Research Center of Medical Electronics and Information Technology, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Kar Man Lo
- California Medical Innovations Institute, San Diego, CA, USA
| | - Ssu-Chi Chen
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kaori Futaba
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Hans Gregersen
- California Medical Innovations Institute, San Diego, CA, USA
| |
Collapse
|
2
|
Sun D, Lo KM, Chen SC, Leung WW, Wong C, Mak T, Ng S, Futaba K, Gregersen H. The rectum, anal sphincter and puborectalis muscle show different contraction wave forms during prolonged measurement with a simulated feces. Sci Rep 2024; 14:432. [PMID: 38172283 PMCID: PMC10764324 DOI: 10.1038/s41598-023-50655-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 12/22/2023] [Indexed: 01/05/2024] Open
Abstract
Contractile patterns in rectum, puborectalis muscle and anal sphincter must be studied to understand defecation. Six subjects had contractile waveforms studied with Fecobionics. Symptom questionnaires, balloon expulsion test and anorectal manometry were done for reference. The Fecobionics bag was filled in rectum to urge-to-defecate volume and measurements were done for 4 h before the subjects attempted to evacuate the device. Pressures and bend angle (BA) variations were analyzed with Fast Fourier Transformation. Four normal subjects exhibited low frequency waves (< 0.06 Hz) for pressures and BA. The waves were uncoordinated between recordings, except for rear and bag pressures. Peak wave amplitudes occurred at 0.02-0.04 Hz. Pressures and the BA differed for peak 1 (p < 0.001) and peak 2 amplitudes (p < 0.005). The front pressure amplitude was bigger than the others (rear and BA, p < 0.05; bag, p < 0.005) for peak 1, and bigger than bag pressure (p < 0.005) and BA (p < 0.05) for peak 2. One subject was considered constipated with lower front pressure amplitudes compared to normal subjects and increased amplitudes for other parameters. The sixth subject was hyperreactive and differed from the other subjects. In conclusion, the rectum, anal sphincter and puborectalis muscle showed different contraction waves during prolonged measurements. The data call for larger studies to better understand normal defecation, feces-withholding patterns, and the implications on anorectal disorders.
Collapse
Affiliation(s)
- Daming Sun
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Kar Man Lo
- California Medical Innovations Institute, 11107 Roselle St., San Diego, CA, 92121, USA
| | - Ssu-Chi Chen
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kaori Futaba
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Hans Gregersen
- California Medical Innovations Institute, 11107 Roselle St., San Diego, CA, 92121, USA.
| |
Collapse
|
3
|
Gregersen H, Sun D, Field F, Combs W, Christensen P, Mousa H, Moawad FJ, Eisenstein S, Kassab GS. Fecobionics in proctology: review and perspectives. SURGERY OPEN DIGESTIVE ADVANCE 2023; 12:100117. [PMID: 38313319 PMCID: PMC10838111 DOI: 10.1016/j.soda.2023.100117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/06/2024]
Abstract
Fecobionics is a novel integrated technology for assessment of anorectal function. It is a defecatory test with simultaneous measurements of pressures, orientation, and device angle (a proxy of the anorectal angle). Furthermore, the latest Fecobionics prototypes measure diameters (shape) using impedance planimetry during evacuation of the device. The simultaneous measurement of multiple variables in the integrated test allows new metrics to be developed including more advanced novel defecation indices, enabling mechanistic insight in the defecation process at an unprecedented level in patients with anorectal disorders including patients suffering from obstructed defecation, fecal incontinence, and low anterior resection syndrome. The device has the consistency and shape of a normal stool (type 3-4 on the Bristol Stool Form Scale). Fecobionics has been validated on the bench and in animal studies and used in clinical trials to study defecation phenotypes in normal human subjects and patients with obstructed defecation, fecal incontinence, and low anterior resection syndrome after rectal cancer surgery. Subtypes have been defined, especially of patients with obstructed defecation. Furthermore, Fecobionics has been used to monitor biofeedback therapy in patients with fecal incontinence to predict the outcome of the therapy (responder versus non-responder). Most Fecobionics studies showed a closer correlation to symptoms as compared to current technologies for anorectal assessment. The present article outlines previous and ongoing work, and perspectives for future studies in proctology, including in physiological assessment of function, diagnostics, monitoring of therapy, and as a tool for biofeedback therapy.
Collapse
Affiliation(s)
- H Gregersen
- California Medical Innovations Institute, San Diego, California, USA
| | - D Sun
- School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, China
| | - F Field
- S3DT Holdings, San Diego, California, USA
| | - W Combs
- S3DT Holdings, San Diego, California, USA
| | - P Christensen
- Department of Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - H Mousa
- CHOP, University of Pennsylvania, Philadelphia, Pennsylvania
| | - F J Moawad
- Scripps Clinic, Division of Gastroenterology, La Jolla, California, USA
| | - S Eisenstein
- Department of Surgery, University of California San Diego, La Jolla, California, USA
| | - G S Kassab
- California Medical Innovations Institute, San Diego, California, USA
| |
Collapse
|
4
|
Yin Y, Zhang Y, Qian C. Association of delivery mode and number of pregnancies with anorectal manometry data in patients with postpartum constipation. BMC Pregnancy Childbirth 2023; 23:160. [PMID: 36899308 PMCID: PMC10007787 DOI: 10.1186/s12884-023-05480-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 03/01/2023] [Indexed: 03/12/2023] Open
Abstract
OBJECTIVE To explore the association of delivery mode and the number of pregnancies with anorectal manometry data in patients with postpartum constipation. METHODS This retrospective study included women with postpartum constipation treated at the pelvic floor rehabilitation department of Huzhou Maternity & Child Health Care Hospital between January 2018 and December 2019. RESULTS Among 127 patients included, 55 (43.3%) had one pregnancy, 72 (56.7%) had two pregnancies, 96 (75.6%) delivered spontaneously, 25 (16.7%) underwent Cesarean section, and six (4.7%) needed a Cesarean section despite spontaneous labor. The median duration of constipation was 12 months (range, 6-12). There were no differences between the two groups for any manometry parameters (all P > 0.05). The patients with a spontaneous delivery had a lower change in maximal contracting sphincter pressure compared with those with Cesarean section (14.3 (4.5-25.0) vs. 19.6 (13.4-40.0), P = 0.023). Only the delivery mode (Cesarean vs. spontaneous) independently affected the changes in contracting sphincter pressure (B = 10.32, 95%CI: 2.95-17.69, P = 0.006); age (P = 0.201), number of pregnancies (P = 0.190), and constipation duration (P = 0.161) were not associated. CONCLUSION The patients with a spontaneous delivery had a lower change in maximal contracting sphincter pressure compared with those with a Cesarean section, suggesting that patients with Cesarean may retain a better "push" function during defecation.
Collapse
Affiliation(s)
- Yan Yin
- General surgery department, Huzhou Maternity and Child Health Care Hospital, 313000, Huzhou, China.
| | - Yumin Zhang
- General surgery department, Huzhou Maternity and Child Health Care Hospital, 313000, Huzhou, China
| | - Cheng Qian
- General surgery department, Huzhou Maternity and Child Health Care Hospital, 313000, Huzhou, China
| |
Collapse
|
5
|
Lo KM, Sun D, Chen SC, Leung WW, Wong C, Mak T, Ng S, Futaba K, Gregersen H. Defecatory Function Studies Using the Fecobionics Device Are Repeatable. Dig Dis Sci 2023; 68:2501-2507. [PMID: 36879178 DOI: 10.1007/s10620-023-07889-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 02/17/2023] [Indexed: 03/08/2023]
Abstract
BACKGROUND Only limited data exist on repeatability of anorectal studies with the established physiological and clinical technologies for assessment of anorectal function. Fecobionics is a new multi-sensor simulated feces that provide data by integrating elements from current tests. AIMS To study repeatability of anorectal data obtained with the Fecobionics device. METHODS We assessed the database of Fecobionics studies to determine how many repeated studies were done. From a total of 260 Fecobionics studies, 19 subjects with repeated studies using approximately the same protocol and prototype were identified. Key pressure and bending parameters were assessed and the repeatability analyzed using Bland Altman plots. Furthermore, the inter- and intra-individual coefficient of variation (CV) were computed. RESULTS Fifteen subjects (5F/10 M) with repeated studies were normal subjects, three were patients with fecal incontinence and one subject suffered from chronic constipation. The main analysis was conducted on the cohort of normal subjects. The bias for 11 parameters were within the confidence interval, whereas two were slightly outside. The interindividual CV was lowest for the bend angle (10.1-10.7) and between 16.3 and 51.6 for the pressure parameters. The intra-individual CVs were approximately half of the inter-individual CVs, spanning from 9.7 to 27.6. CONCLUSION All data from normal subjects were within previously defined normality. The Fecobionics data showed acceptable repeatability with bias within the confidence limits for almost all parameters. The intra-individual CV was much lower than the inter-individual CV. Dedicated large-scale studies are warranted to evaluate the influence of age, sex, and disease on repeatability as well as comparing between technologies.
Collapse
Affiliation(s)
- Kar Man Lo
- California Medical Innovations Institute, San Diego, CA, USA
| | - Daming Sun
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Ssu-Chi Chen
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kaori Futaba
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Hans Gregersen
- California Medical Innovations Institute, San Diego, CA, USA.
| |
Collapse
|
6
|
Bharucha AE, Basilisco G, Malcolm A, Lee TH, Hoy MB, Scott SM, Rao SSC. Review of the indications, methods, and clinical utility of anorectal manometry and the rectal balloon expulsion test. Neurogastroenterol Motil 2022; 34:e14335. [PMID: 35220645 PMCID: PMC9418387 DOI: 10.1111/nmo.14335] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 01/24/2022] [Accepted: 02/01/2022] [Indexed: 02/06/2023]
Abstract
BACKGROUND Anorectal manometry (ARM) comprehensively assesses anorectal sensorimotor functions. PURPOSE This review examines the indications, techniques, interpretation, strengths, and weaknesses of high-resolution ARM (HR-ARM), 3-dimensional high-resolution anorectal manometry (3D-HR-ARM), and portable ARM, and other assessments (i.e., rectal sensation and rectal balloon expulsion test) that are performed alongside manometry. It is based on a literature search of articles related to ARM in adults. HR-ARM and 3D-HR-ARM are useful for diagnosing defecatory disorders (DD), to identify anorectal sensorimotor dysfunction and guide management in patients with fecal incontinence (FI), constipation, megacolon, and megarectum; and to screen for anorectal structural (e.g., rectal intussusception) abnormalities. The rectal balloon expulsion test is a useful, low-cost, radiation-free, outpatient assessment tool for impaired evacuation that is performed and interpreted in conjunction with ARM. The anorectal function tests should be interpreted with reference to age- and sex-matched normal values, clinical features, and results of other tests. A larger database of technique-specific normal values and newer paradigms of analyzing anorectal pressure profiles will increase the precision and diagnostic utility of HR-ARM for identifying abnormal mechanisms of defecation and continence.
Collapse
Affiliation(s)
- Adil E Bharucha
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Guido Basilisco
- UO Gastroenterologia, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milano, Italy
| | - Allison Malcolm
- Department of Gastroenterology, Royal North Shore Hospital and University of Sydney, Sydney, NSW, Australia
| | - Tae Hee Lee
- Digestive Disease Center, Soonchunhyang University Seoul Hospital, Seoul, Korea
| | - Matthew B Hoy
- Mayo Medical Library, Mayo Clinic, Rochester, Minnesota, USA
| | - S Mark Scott
- National Bowel Research Centre, Queen Mary University of London, London, UK
| | - Satish S C Rao
- Department of Gastroenterology, Augusta University, Augusta, Georgia, USA
| |
Collapse
|
7
|
Futaba K, Chen SC, Leung WW, Wong C, Mak T, Ng S, Gregersen H. Fecobionics characterization of female patients with fecal incontinence. Sci Rep 2022; 12:10602. [PMID: 35732729 PMCID: PMC9218093 DOI: 10.1038/s41598-022-14919-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 06/15/2022] [Indexed: 12/12/2022] Open
Abstract
Defecatory disorders including fecal incontinence (FI) are diagnosed on the symptom pattern supplemented by anorectal manometry (ARM), the balloon expulsion test (BET), and endo-anal ultrasonography. In this study, we used a simulated stool named Fecobionics to study distinct defecation patterns in FI patients using preload-afterload diagrams and to provide comparative data on defecation indices (DIs) between passive and urge incontinent patients. All subjects had Fecobionics, endo-anal ultrasonography and ARM-BET done. The Fecobionics bag was distended in rectum until urge in 37 female patients (64.1 ± 1.5 yrs) and a group of normal subjects (NS, 12F, age 64.8 ± 2.8 yrs). Rear-front pressure (preload-afterload) diagrams and DIs were compared between groups. The FISI score in the patients was 8.6 ± 0.6. The NS did not report FI-related symptoms. All patients and NS defecated Fecobionics and ARM-BET within 2 min. The urge volume was 46.1 ± 3.6 and 35.3 ± 5.9 mL in the FI and normal groups (P > 0.1). The expulsion duration was 14.8 ± 2.4 and 19.8 ± 5.1 s for the two groups (P > 0.1). The preload-afterload diagrams demonstrated clockwise loops that clearly differed between the FI subtypes and NS. The DIs showed profound difference between patients and NS. Fecobionics data showed higher correlation with symptoms in FI patients than ARM-BET. Fecobionics obtained novel pressure signatures in subtypes of FI patients and NS. Fecobionics provides DI data that cannot be obtained with ARM-BET.
Collapse
Affiliation(s)
- Kaori Futaba
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Ssu-Chi Chen
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Hans Gregersen
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong.
- California Medical Innovations Institute, 11107 Roselle St., San Diego, CA, 92121, USA.
| |
Collapse
|
8
|
Gregersen H, Wang Y, Field F, Wang M, Lo KM, Guo X, Combs W, Kassab GS. Feasibility study of defecation studied with a wireless Fecobionics probe in normal subjects. Physiol Rep 2022; 10:e15338. [PMID: 35656707 PMCID: PMC9163794 DOI: 10.14814/phy2.15338] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/12/2022] [Accepted: 05/17/2022] [Indexed: 06/15/2023] Open
Abstract
Several technologies have been developed for assessing anorectal function including the act of defecation. We used a new prototype of the Fecobionics technology, a multi-sensor simulated feces, to visualize defecatory patterns and introduced new metrics for anorectal physiology assessment in normal subjects. Fourteen subjects with normal fecal incontinence and constipation questionnaire scores were studied. The 10-cm-long Fecobionics device provided measurements of axial pressures, orientation, bending, and shape. The Fecobionics bag was distended to the urge-to-defecate level inside rectum where after the subjects were asked to evacuate. Physiological evacuation parameters were assessed. Special attention was paid to the Fecobionics rectoanal pressure gradient (F-RAPG) during evacuation. Anorectal manometry (ARM) and balloon expulsion test (BET) were done as references. The user interface displayed the fine coordination between pressures, orientation, bending angle, and shape. The pressures showed that Fecobionics was expelled in 11.5 s (quartiles 7.5 and 18.8s), which was shorter than the subjectively reported expulsion time of the BET balloon. Six subjects did not expel the BET balloon within 2 min. The F-RAPG was 101 (79-131) cmH2 O, whereas the ARM-RAPG was -28 (-5 to -47) cmH2 0 (p < 0.001). There was no association between the two RAPGs (r2 = 0.19). Fecobionics showed paradoxical contractions in one subject (7%) compared to 12 subjects with ARM (86%). Fecobionics obtained novel physiological data. Defecatory patterns and data are reported and can be used to guide larger-scale studies in normal subjects and patients with defecatory disorders. In accordance with other studies, this Fecobionics study questions the value of the ARM-RAPG.
Collapse
Affiliation(s)
- Hans Gregersen
- California Medical Innovations InstituteSan DiegoCaliforniaUSA
| | - Yanmin Wang
- California Medical Innovations InstituteSan DiegoCaliforniaUSA
| | | | | | - Kar Man Lo
- California Medical Innovations InstituteSan DiegoCaliforniaUSA
| | - Xiaomei Guo
- California Medical Innovations InstituteSan DiegoCaliforniaUSA
| | | | | |
Collapse
|
9
|
Futaba K, Chen SC, Leung WW, Wong C, Mak T, Ng S, Gregersen H. Fecobionics Evaluation of Biofeedback Therapy in Patients With Fecal Incontinence. Clin Transl Gastroenterol 2022; 13:e00491. [PMID: 35363631 PMCID: PMC9132520 DOI: 10.14309/ctg.0000000000000491] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 03/21/2022] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Biofeedback therapy (BFT) is a well-known treatment for functional anorectal disorders. The effect of BFT was monitored in fecal incontinence (FI) patients with the Fecobionics test and with the conventional technologies, anorectal manometry (ARM) and balloon expulsion test (BET). METHODS Studies were performed in 12 patients before and after 8 weeks of biofeedback training. The Fecal Incontinence Severity Index (FISI) score was obtained. Anal resting and squeeze pressures were measured before the bag was distended in the rectum until urge to defecate. Pressure recordings were made during Fecobionics evacuation. RESULTS BFT resulted in 24% reduction in FISI scores (P < 0.01). Seven patients were characterized as responders. Anal pressures, the urge-to-defecate volume, and defecatory parameters did not change significantly during BFT. For ARM-BET, the maximum anal squeeze pressure, the urge-to-defecate volume, and the expulsion time were lower after BFT compared with those before BFT (P < 0.05). For Fecobionics, the change in urge volume (r = 0.74, P < 0.05) and the change in defecation index (r = 0.79, P < 0.01) were associated with the change in FISI score. None of the ARM-BET parameters were associated with the change in FISI score. It was studied whether any pre-BFT data could predict treatment success. The Fecobionics expulsion duration and the defecation index predicted the outcome (P < 0.05). The defecation index had a sensitivity of 100% and a specificity of 72%. None of the ARM-BET parameters predicted the outcome (all P > 0.2). DISCUSSION Fecobionics was used as a tool to monitor the effect of BFT and proved better than conventional technologies for monitoring and predicting the outcome in the FISI score.
Collapse
Affiliation(s)
- Kaori Futaba
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Ssu-Chi Chen
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Hans Gregersen
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
- California Medical Innovations Institute, San Diego, California, USA
| |
Collapse
|
10
|
Chen SC, Futaba K, Leung WW, Wong C, Mak T, Ng S, Gregersen H. Functional anorectal studies in patients with low anterior resection syndrome. Neurogastroenterol Motil 2022; 34:e14208. [PMID: 34145694 DOI: 10.1111/nmo.14208] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 05/24/2021] [Accepted: 06/01/2021] [Indexed: 12/23/2022]
Abstract
BACKGROUND Most patients who have undergone low anterior resection suffer from bowel dysfunction postoperatively. This condition is referred to as low anterior resection syndrome (LARS). The aim was to study defecatory patterns in LARS patients compared to a primary control group of fecal incontinence (FI) patients and normal subjects (NS) with the Fecobionics device. METHODS Fecobionics expulsion parameters were assessed in an interventional study design. The Fecobionics probe contained pressure sensors at the front, rear, and inside the bag. The bag was distended until urge sensation in rectum in 11 LARS patients (5F/6M, 63.2 ± 2.9 years), 11 FI subjects (7F/4M, 64.4 ± 2.5 years), and 11 NS (7F/4M, 63.6 ± 3.0 years). Defecation indices were computed from the Fecobionics data. All subjects had high-resolution anorectal manometry (ARM) and balloon expulsion test (BET) done. Symptoms were evaluated with LARS and Wexner scores. KEY RESULTS The LARS score in the LARS patients was 39.0 ± 0.6. The Wexner score in the LARS, FI, and NS groups was 14.2 ± 0.7, 10.1±1.0, and 0.0 ± 0.0 (p < 0.01). The resting anal pressure and squeeze pressure were lowest in LARS patients (p < 0.05). The urge volume was 11.8 ± 4.2, 59.6 ± 6.4, and 41.6 ± 6.4 ml in the LARS, FI, and NS groups, respectively (p < 0.001). The expulsion duration did not differ between groups. Defecation indices were lowest in the LARS patients (p < 0.05). ARM-BET confirmed the low urge volume in LARS patients whereas anal pressures did not differ between groups. CONCLUSIONS AND INFERENCES The LARS patients had low anal pressures and urge volume. Most Defecation Indices differed between the LARS group and the other groups.
Collapse
Affiliation(s)
- Ssu-Chi Chen
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kaori Futaba
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong
| | - Hans Gregersen
- Department of Surgery, the Chinese University of Hong Kong, Shatin, Hong Kong.,California Medical Innovations Institute, San Diego, CA, USA
| |
Collapse
|
11
|
Gregersen H, Chen SC, Leung WW, Wong C, Mak T, Ng S, Futaba K. Fecobionics Characterization of Patients With Fecal Incontinence. Clin Gastroenterol Hepatol 2021; 19:2447-2449. [PMID: 33127594 DOI: 10.1016/j.cgh.2020.10.043] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 10/17/2020] [Accepted: 10/21/2020] [Indexed: 02/07/2023]
Abstract
Fecal incontinence (FI) is characterized by involuntary loss of rectal content. Up to 9.5% of Americans younger than 70 years suffer from FI.1 The pathophysiology has many causes and is not well understood and diagnosed.
Collapse
Affiliation(s)
- Hans Gregersen
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong.
| | - Ssu-Chi Chen
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Wing Wa Leung
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Cherry Wong
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Tony Mak
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Simon Ng
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kaori Futaba
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong
| |
Collapse
|
12
|
Kassab GS, Gregersen H, Sun D, Huang Z. Novel bionics developments in gastroenterology: fecobionics assessment of lower GI tract function. Physiol Meas 2021; 42. [PMID: 34190049 DOI: 10.1088/1361-6579/ac023c] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Accepted: 05/17/2021] [Indexed: 11/12/2022]
Abstract
Biomechatronics (bionics) is an applied science that is interdisciplinary between biology and engineering (mechanical, electrical and electronics engineering). Biomechatronics covers a wide area and is probably best known in development of prosthetic limbs, vision aids, robotics and neuroscience. Although the gastrointestinal tract is difficult to study, it is particularly suited for a bionics approach as demonstrated by recent developments. Ingestible capsules that travel the tract and record physiological variables have been used in the clinic. Other examples include sacral nerve stimulators that seek to restore normal anorectal function. Recently, we developed a simulated stool termed fecobionics. It has the shape of normal stool and records a variety of parameters including pressures, bending (anorectal angle) and shape changes during colonic transit and defecation, i.e. it integrates several current tests. Fecobionics has been used to study defecation patterns in large animals as well as in humans (normal subjects and patient groups including patients with symptoms of obstructed defecation and fecal incontinence). Recently, it was applied in a canine colon model where it revealed patterns consistent with shallow waves originating from slow waves generated by the interstitial cells of Cajal. Furthermore, novel analysis such as the rear-front pressure (preload-afterload) diagram and quantification of defecation indices have been developed that enable mechanistic insight. This paper reviews the fecobionics technology and outlines perspectives for future applications.
Collapse
Affiliation(s)
- G S Kassab
- California Medical Innovations Institute, San Diego, CA, United States of America
| | - H Gregersen
- California Medical Innovations Institute, San Diego, CA, United States of America
| | - D Sun
- School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, People's Republic of China
| | - Z Huang
- School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, People's Republic of China
| |
Collapse
|
13
|
Chen SC, Futaba K, Leung WW, Wong C, Mak T, Ng S, Gregersen H. Fecobionics assessment of the effect of position on defecatory efficacy in normal subjects. Tech Coloproctol 2021; 25:559-568. [PMID: 33779850 DOI: 10.1007/s10151-021-02439-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 03/20/2021] [Indexed: 12/15/2022]
Abstract
BACKGROUND Defecation is a complex process and up to 25% of the population suffer from symptoms of defecatory dysfunction. For functional testing, diagnostics, and therapy of anorectal disorders, it is important to know the optimal defecation position. is The aim of this study was to evaluate defecation pressure patterns in side lying, seated and squatting defecation positions in normal subjects using a simulated stool device called Fecobionics. METHODS The Fecobionics expulsion parameters were assessed in an interventional study design conducted from May 29 to December 9 2019. Subjects were invited to participate in the study through advertisement at The Chinese University of Hong Kong. The Fecobionics device consisted of a core containing pressure sensors at the front (caudal end) and rear (cranial end) and a polyester-urethane bag spanning most of the core length which also contained sensors. The Fecobionics bag was distended to 50 ml in the rectum of normal subjects (no present and past symptoms of defecatory disorders, no prior abdominal surgery, medication or chronic diseases). Studies were done in side lying (left lateral recumbent position), seated (hip flexed 90°) and squatting position (hip flexed 25°). Pressure endpoints including the rear-front pressure diagram and defecation indices were compared between positions. RESULTS Twelve subjects (6 females/6 males, mean age 26.3 ± 2.6 [19.0-48.0] years) were included and underwent the planned procedures. The resting anal pressure for side lying and seated positions were 33.1 ± 4.1 cmH2O and 37.1 ± 4.0 cmH2O (p > 0.3). The anal squeeze pressure for side lying and seated positions were 98.4 ± 6.9 cmH2O and 142.3 ± 16.4 cmH2O (p < 0.05). The expulsion duration for the side lying, seated and squatting positions were 108.9 ± 8.3 s, 15.0 ± 2.1 s and 16.1 ± 2.9 s, respectively (p < 0.01 between lying and the two other positions). The maximum evacuation pressure for seated and squatting were 130.1 ± 12.4 cmH2O and 134.0 ± 11.1 cmH2O (p > 0.5). Rear-front pressure diagrams and distensibility indices demonstrated distinct differences in pressure patterns between the side lying position group and the other positions. CONCLUSIONS The delay in expelling the Fecobionics device in the lying position was associated with dyssynergic pressure patterns on the device. Quantitative differences were not found between the seated and squatting position. Trial Registration http://www.clinicaltrials.gov Identifier: NCT03317938.
Collapse
Affiliation(s)
- S-C Chen
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China
| | - K Futaba
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China
| | - W W Leung
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China
| | - C Wong
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China
| | - T Mak
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China
| | - S Ng
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China
| | - H Gregersen
- GIOME, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, 4/F, Clinical Sciences Building, Shatin, Hong Kong, China.
| |
Collapse
|
14
|
Abstract
OBJECTIVE Fecobionics was used to assess pressures, orientation, bending, shape, and cross-sectional area (CSA) changes during defecation. This study aimed to evaluate the device feasibility and performance in swine. APPROACH Twelve pigs had wired or wireless Fecobionics devices inserted in the rectum. The bag was distended to simulate feces in the rectum. Fecobionics data were acquired simultaneously during the whole experiment. Six pigs were euthanized immediately after the procedure for evaluation of acute injury to anorectum (acute group). The remaining pigs lived two weeks before euthanasia for evaluation of long-term tissue damage and inflammation (chronic group). Signs of discomfort were monitored. MAIN RESULTS All animals tolerated the experiment well. The chronic animals showed normal behavior after the procedure. Mucosal damage, bleeding, or inflammation was not found in either group. Fecobionics was defecated 1 min 35 s-61 min 0 s (median 8 min 58 s) after insertion. The defecation lasted 0 min 20 s-4 min 25 s (median 1 min 52 s). The device was almost straight inside rectum (160°-180°) but usually bended 5°-20° during contractions. The three pressure sensors showed simultaneous and identical increase during rectal or abdominal muscle contractions, indicating the location inside rectum. During defecation, the maximum rear pressure was 114.1 ± 14.3 cmH2O whereas the front pressure gradually decreased to 0 cmH2O, indicating the front passed anus. CSA decreased from 1017.1 ± 191.0 mm2 to 530.7 ± 46.5 mm2 when the probe passed from the rectum through the anal canal. SIGNIFICANCE Fecobionics provides defecatory measurements under physiological conditions in pigs without inducing tissue damage.
Collapse
Affiliation(s)
- Yanmin Wang
- California Medical Innovations Institute, San Diego, CA, United States of America
| | | | | | | |
Collapse
|