Yang L, Gao Z, Cao X, Sun S, Wang C, Wang H, Dai J, Liu Y, Qin Y, Dai M, Guo W, Zhang B, Zhao K, Zhao Z. Electrical impedance tomography as a bedside assessment tool for COPD treatment during hospitalization. Front Physiol 2024; 15:1352391. [PMID: 38562620 PMCID: PMC10982416 DOI: 10.3389/fphys.2024.1352391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 03/06/2024] [Indexed: 04/04/2024] Open
Abstract
For patients with chronic obstructive pulmonary disease (COPD), the assessment of the treatment efficacy during hospitalization is of importance to the optimization of clinical treatments. Conventional spirometry might not be sensitive enough to capture the regional lung function development. The study aimed to evaluate the feasibility of using electrical impedance tomography (EIT) as an objective bedside evaluation tool for the treatment of acute exacerbation of COPD (AECOPD). Consecutive patients who required hospitalization due to AECOPD were included prospectively. EIT measurements were conducted at the time of admission and before the discharge simultaneously when a forced vital capacity maneuver was conducted. EIT-based heterogeneity measures of regional lung function were calculated based on the impedance changes over time. Surveys for attending doctors and patients were designed to evaluate the ease of use, feasibility, and overall satisfaction level to understand the acceptability of EIT measurements. Patient-reported outcome assessments were conducted. User's acceptance of EIT technology was investigated with a five-dimension survey. A total of 32 patients were included, and 8 patients were excluded due to the FVC maneuver not meeting the ATS criteria. Spirometry-based lung function was improved during hospitalization but not significantly different (FEV1 %pred.: 35.8% ± 6.7% vs. 45.3% ± 8.8% at admission vs. discharge; p = 0.11. FVC %pred.: 67.8% ± 0.4% vs. 82.6% ± 5.0%; p = 0.15. FEV1/FVC: 0.41 ± 0.09 vs. 0.42 ± 0.07, p = 0.71). The symptoms of COPD were significantly improved, but the correlations between the improvement of symptoms and spirometry FEV1 and FEV1/FVC were low (R = 0.1 and -0.01, respectively). The differences in blood gasses and blood tests were insignificant. All but one EIT-based regional lung function parameter were significantly improved after hospitalization. The results highly correlated with the patient-reported outcome assessment (R > 0.6, p < 0.001). The overall acceptability score of EIT measurement for both attending physicians and patients was high (4.1 ± 0.8 for physicians, 4.5 ± 0.5 for patients out of 5). These results demonstrated that it was feasible and acceptable to use EIT as an objective bedside evaluation tool for COPD treatment efficacy.
Collapse
Affiliation(s)
- Lin Yang
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Zhijun Gao
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Xinsheng Cao
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Shuying Sun
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Chunchen Wang
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Hang Wang
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Jing Dai
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Yang Liu
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Yilong Qin
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Meng Dai
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Wei Guo
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Binghua Zhang
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Ke Zhao
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Zhanqi Zhao
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
2
|
Heines SJH, Becher TH, van der Horst ICC, Bergmans DCJJ. Clinical Applicability of Electrical Impedance Tomography in Patient-Tailored Ventilation: A Narrative Review. Tomography 2023; 9:1903-1932. [PMID: 37888742 PMCID: PMC10611090 DOI: 10.3390/tomography9050150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/05/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive bedside imaging technique that provides real-time lung ventilation information on critically ill patients. EIT can potentially become a valuable tool for optimising mechanical ventilation, especially in patients with acute respiratory distress syndrome (ARDS). In addition, EIT has been shown to improve the understanding of ventilation distribution and lung aeration, which can help tailor ventilatory strategies according to patient needs. Evidence from critically ill patients shows that EIT can reduce the duration of mechanical ventilation and prevent lung injury due to overdistension or collapse. EIT can also identify the presence of lung collapse or recruitment during a recruitment manoeuvre, which may guide further therapy. Despite its potential benefits, EIT has not yet been widely used in clinical practice. This may, in part, be due to the challenges associated with its implementation, including the need for specialised equipment and trained personnel and further validation of its usefulness in clinical settings. Nevertheless, ongoing research focuses on improving mechanical ventilation and clinical outcomes in critically ill patients.
Collapse
Affiliation(s)
- Serge J. H. Heines
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
| | - Tobias H. Becher
- Department of Anesthesiology and Intensive Care Medicine, Campus Kiel, University Medical Centre Schleswig-Holstein, 24118 Kiel, Germany;
| | - Iwan C. C. van der Horst
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 HX Maastricht, The Netherlands
| | - Dennis C. J. J. Bergmans
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, 6229 ER Maastricht, The Netherlands
| |
Collapse
|
3
|
Chen R, Krueger-Ziolek S, Lovas A, Benyó B, Rupitsch SJ, Moeller K. Structural priors represented by discrete cosine transform improve EIT functional imaging. PLoS One 2023; 18:e0285619. [PMID: 37167237 PMCID: PMC10174522 DOI: 10.1371/journal.pone.0285619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 04/26/2023] [Indexed: 05/13/2023] Open
Abstract
Structural prior information can improve electrical impedance tomography (EIT) reconstruction. In this contribution, we introduce a discrete cosine transformation-based (DCT-based) EIT reconstruction algorithm to demonstrate a way to incorporate the structural prior with the EIT reconstruction process. Structural prior information is obtained from other available imaging methods, e.g., thorax-CT. The DCT-based approach creates a functional EIT image of regional lung ventilation while preserving the introduced structural information. This leads to an easier interpretation in clinical settings while maintaining the advantages of EIT in terms of bedside monitoring during mechanical ventilation. Structural priors introduced in the DCT-based approach are of two categories in terms of different levels of information included: a contour prior only differentiates lung and non-lung region, while a detail prior includes information, such as atelectasis, within the lung area. To demonstrate the increased interpretability of the EIT image through structural prior in the DCT-based approach, the DCT-based reconstructions were compared with reconstructions from a widely applied one-step Gauss-Newton solver with background prior and from the advanced GREIT algorithm. The comparisons were conducted both on simulation data and retrospective patient data. In the simulation, we used two sets of forward models to simulate different lung conditions. A contour prior and a detail prior were derived from simulation ground truth. With these two structural priors, the reconstructions from the DCT-based approach were compared with the reconstructions from both the one-step Gauss-Newton solver and the GREIT. The difference between the reconstructions and the simulation ground truth is calculated by the ℓ2-norm image difference. In retrospective patient data analysis, datasets from six lung disease patients were included. For each patient, a detail prior was derived from the patient's CT, respectively. The detail prior was used for the reconstructions using the DCT-based approach, which was compared with the reconstructions from the GREIT. The reconstructions from the DCT-based approach are more comprehensive and interpretable in terms of preserving the structure specified by the priors, both in simulation and retrospective patient data analysis. In simulation analysis, the ℓ2-norm image difference of the DCT-based approach with a contour prior decreased on average by 34% from GREIT and 49% from the Gauss-Newton solver with background prior; for reconstructions of the DCT-based approach with detail prior, on average the ℓ2-norm image difference is 53% less than GREIT and 63% less than the reconstruction with background prior. In retrospective patient data analysis, the reconstructions from both the DCT-based approach and GREIT can indicate the current patient status, but the DCT-based approach yields more interpretable results. However, it is worth noting that the preserved structure in the DCT-based approach is derived from another imaging method, not from the EIT measurement. If the structural prior is outdated or wrong, the result might be misleadingly interpreted, which induces false clinical conclusions. Further research in terms of evaluating the validity of the structural prior and detecting the outdated prior is necessary.
Collapse
Affiliation(s)
- Rongqing Chen
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
- Faculty of Engineering, University of Freiburg, Freiburg, Germany
| | - Sabine Krueger-Ziolek
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| | - András Lovas
- Department of Anaesthesiology and Intensive Therapy, Kiskunhalas Semmelweis Hospital, Kiskunhalas, Hungary
| | - Balázs Benyó
- Department of Control Engineering and Information Technology, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, Budapest, Hungary
| | | | - Knut Moeller
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
4
|
Zhang C, Wang Y, Liu L, Li Q, Li Y, Li N, Xi J, Jiang H, Fu F, Frerichs I, Möller K, Zhao Z. Regional ventilation distribution in patients with scoliosis assessed by electrical impedance tomography: is individual thorax shape required? Respir Physiol Neurobiol 2022; 299:103854. [DOI: 10.1016/j.resp.2022.103854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 01/20/2022] [Accepted: 01/28/2022] [Indexed: 10/19/2022]
|
5
|
Frerichs I, Lasarow L, Strodthoff C, Vogt B, Zhao Z, Weiler N. Spatial Ventilation Inhomogeneity Determined by Electrical Impedance Tomography in Patients With Chronic Obstructive Lung Disease. Front Physiol 2021; 12:762791. [PMID: 34966289 PMCID: PMC8712108 DOI: 10.3389/fphys.2021.762791] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Accepted: 11/16/2021] [Indexed: 11/13/2022] Open
Abstract
The aim of this study was to examine whether electrical impedance tomography (EIT) could determine the presence of ventilation inhomogeneity in patients with chronic obstructive lung disease (COPD) from measurements carried out not only during conventional forced full expiration maneuvers but also from forced inspiration maneuvers and quiet tidal breathing and whether the inhomogeneity levels were comparable among the phases and higher than in healthy subjects. EIT data were acquired in 52 patients with exacerbated COPD (11 women, 41 men, 68 ± 11 years) and 14 healthy subjects (6 women, 8 men, 38 ± 8 years). Regional lung function parameters of forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), forced inspiratory vital capacity (FIVC), forced inspiratory volume in 1 s (FIV1), and tidal volume (V T ) were determined in 912 image pixels. The spatial inhomogeneity of the pixel parameters was characterized by the coefficients of variation (CV) and the global inhomogeneity (GI) index. CV and GI values of pixel FVC, FEV1, FIVC, FIV1, and VT were significantly higher in patients than in healthy subjects (p ≤ 0.0001). The ventilation distribution was affected by the analyzed lung function parameter in patients (CV: p = 0.0024, GI: p = 0.006) but not in healthy subjects. Receiver operating characteristic curves showed that CV and GI discriminated patients from healthy subjects with an area under the curve (AUC) of 0.835 and 0.852 (FVC), 0.845 and 0.867 (FEV1), 0.903 and 0.903 (FIVC), 0.891 and 0.882 (FIV1), and 0.821 and 0.843 (VT), respectively. These findings confirm the ability of EIT to identify increased ventilation inhomogeneity in patients with COPD.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Livia Lasarow
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Claas Strodthoff
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Barbara Vogt
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Norbert Weiler
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Kiel, Germany
| |
Collapse
|
6
|
Groenendaal W, Lee S, van Hoof C. Wearable Bioimpedance Monitoring: Viewpoint for Application in Chronic Conditions. JMIR BIOMEDICAL ENGINEERING 2021; 6:e22911. [PMID: 38907374 PMCID: PMC11041432 DOI: 10.2196/22911] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 03/01/2021] [Accepted: 04/06/2021] [Indexed: 01/20/2023] Open
Abstract
Currently, nearly 6 in 10 US adults are suffering from at least one chronic condition. Wearable technology could help in controlling the health care costs by remote monitoring and early detection of disease worsening. However, in recent years, there have been disappointments in wearable technology with respect to reliability, lack of feedback, or lack of user comfort. One of the promising sensor techniques for wearable monitoring of chronic disease is bioimpedance, which is a noninvasive, versatile sensing method that can be applied in different ways to extract a wide range of health care parameters. Due to the changes in impedance caused by either breathing or blood flow, time-varying signals such as respiration and cardiac output can be obtained with bioimpedance. A second application area is related to body composition and fluid status (eg, pulmonary congestion monitoring in patients with heart failure). Finally, bioimpedance can be used for continuous and real-time imaging (eg, during mechanical ventilation). In this viewpoint, we evaluate the use of wearable bioimpedance monitoring for application in chronic conditions, focusing on the current status, recent improvements, and challenges that still need to be tackled.
Collapse
Affiliation(s)
| | - Seulki Lee
- Imec the Netherlands / Holst Centre, Eindhoven, Netherlands
| | - Chris van Hoof
- Imec, Leuven, Belgium
- One Planet Research Center, Wageningen, Netherlands
- Department of Engineering Science, KU Leuven, Leuven, Belgium
| |
Collapse
|
7
|
Yang L, Dai M, Cao X, Möller K, Dargvainis M, Frerichs I, Becher T, Fu F, Zhao Z. Regional ventilation distribution in healthy lungs: can reference values be established for electrical impedance tomography parameters? ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:789. [PMID: 34268402 PMCID: PMC8246208 DOI: 10.21037/atm-20-7442] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 01/24/2021] [Indexed: 12/26/2022]
Abstract
Background Although electrical impedance tomography (EIT) is widely used for monitoring regional ventilation distribution, reference values have yet to be established for clinical use. The present study aimed to evaluate the feasibility of creating reference values for standard EIT parameters for potential clinical application. Methods A total of 75 participants with healthy lungs were included in this prospective study (male:female, 48:27; age, 34±14 years; height, 172±7 cm; weight, 73±12 kg). The subjects were examined during spontaneous breathing in the supine position. EIT measurements were performed at the level of the 4th intercostal space. Commonly used EIT-based parameters, including the center of ventilation (CoV), dorsal and most dorsal fractions of ventilation distribution (TVD and TVROI4 respectively), global inhomogeneity (GI) index, and standard deviation of regional ventilation delay index (RVDSD) were calculated. Results Following outlier detection, EIT data from 71 subjects were finally evaluated. The values of the evaluated parameters were: CoV, 48.7%±1.7%; TVD, 48.1%±5.4%; TVROI4, 7.1%±1.8%; GI, 0.49±0.04; and RVDSD, 7.0±2.0. The coefficients of variation for CoV and GI were low (0.03 and 0.07, respectively), but those for TVROI4 and RVDSD were comparatively high (0.26 and 0.28, respectively). None of the evaluated parameters showed a significant correlation with age. The GI index showed a weak but significant correlation with body mass index (R=0.29, P=0.01). The RVDSD was slightly higher in males than in females. Conclusions Our study indicated that CoV and GI were stable parameters with small coefficients of variation in participants with healthy lungs. The creation of EIT parameter reference values for setting treatment targets may be feasible.
Collapse
Affiliation(s)
- Lin Yang
- Department of Aerospace Medicine, Fourth Military Medical University, Xi'an, China
| | - Meng Dai
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Xinsheng Cao
- Department of Aerospace Medicine, Fourth Military Medical University, Xi'an, China
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Mantas Dargvainis
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Inéz Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Tobias Becher
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Feng Fu
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
8
|
Lasarow L, Vogt B, Zhao Z, Balke L, Weiler N, Frerichs I. Regional lung function measures determined by electrical impedance tomography during repetitive ventilation manoeuvres in patients with COPD. Physiol Meas 2021; 42:015008. [PMID: 33434902 DOI: 10.1088/1361-6579/abdad6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE Current standards for conducting spirometry examinations recommend that the ventilation manoeuvres needed in pulmonary function testing are carried out repeatedly during sessions. Chest electrical impedance tomography (EIT) can determine the presence of ventilation heterogeneity during such manoeuvres, which increases the information content derived from such examinations. The aim of this study was to characterise regional lung function in patients with chronic obstructive pulmonary disease (COPD) during repetitive forced full ventilation manoeuvres. Regional lung function measures derived from these manoeuvres were compared with quiet tidal breathing. APPROACH Sixty hospitalised patients were examined during up to three repeated ventilation manoeuvres. Acceptable spirometry manoeuvres were performed and EIT recordings suitable for analysis obtained in 53 patients (12 women, 41 men; age: 68 ± 12 years (mean ± SD)). Pixel values of tidal volume, forced full inspiratory and expiratory volume in 1 s, and forced inspiratory and expiratory vital capacity were calculated from the EIT data. Spatial ventilation heterogeneity was assessed using the coefficient of variation, global inhomogeneity index, and centres and regional fractions of ventilation. Temporal inhomogeneity was determined by examining the pixel expiration times needed to exhale 50% and 75% of regional forced vital capacity. MAIN RESULTS All EIT-derived measures of regional lung function showed reproducible results during repetitive examinations. Parameters of spatial heterogeneity obtained from quiet tidal breathing were comparable with the measures derived from the forced manoeuvres. SIGNIFICANCE Measures of spatial and temporal ventilation heterogeneity obtained in COPD patients by EIT provide comparable findings during repeated examinations within one testing session. Quiet tidal breathing generates similar information on ventilation heterogeneity as forced manoeuvres that demand a high amount of patient effort.
Collapse
Affiliation(s)
- L Lasarow
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - B Vogt
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Z Zhao
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany.,Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, People's Republic of China
| | - L Balke
- Department of Pneumology, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - N Weiler
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - I Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
9
|
Sang L, Zhao Z, Lin Z, Liu X, Zhong N, Li Y. A narrative review of electrical impedance tomography in lung diseases with flow limitation and hyperinflation: methodologies and applications. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1688. [PMID: 33490200 PMCID: PMC7812189 DOI: 10.21037/atm-20-4984] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Electrical impedance tomography (EIT) is a functional radiation-free imaging technique that measures regional lung ventilation distribution by calculating the impedance changes in the corresponding regions. The aim of the present review was to summarize the current literature concerning the methodologies and applications of EIT in lung diseases with flow limitation and hyperinflation. PubMed was searched up to May 2020 to identify studies investigating the use of EIT in patients with asthma, bronchiectasis, bronchitis, bronchiolitis, chronic obstructive pulmonary disease, and cystic fibrosis. The extracted data included study design, EIT methodologies, interventions, validation and comparators, population characteristics, and key findings. Of the 44 included studies, seven were related to simulation, animal experimentation, or reconstruction algorithm development with evaluation on patients; 27 studies had the primary objective of validating EIT technique and measures including regional ventilation distribution, regional EIT-spirometry parameters, end-expiratory lung impedance, and regional time constants; and 10 studies had the primary objective of applying EIT to monitor the response to therapeutic interventions, including various ventilation supports, patient repositioning, and airway suctioning. In pediatric and adult patients, EIT has been successfully validated for assessing spatial and temporal ventilation distribution, measuring changes in lung volume and flow, and studying regional respiratory mechanics. EIT has also demonstrated potential as an alternative or supplement to well-established measurement modalities (e.g., conventional pulmonary function testing) to monitor the progression of obstructive lung diseases, although the existing literature lacks prediction values as references and lacks clinical outcome evidence.
Collapse
Affiliation(s)
- Ling Sang
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Zhimin Lin
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Xiaoqing Liu
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Nanshan Zhong
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| | - Yimin Li
- State Key Laboratory of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou Medical University, the First Affiliated Hospital of Guangzhou Medical University, Department of Crit Care Med, Guangzhou, China
| |
Collapse
|
10
|
Sang L, Zhao Z, Yun PJ, Frerichs I, Möller K, Fu F, Liu X, Zhong N, Li Y. Qualitative and quantitative assessment of pendelluft: a simple method based on electrical impedance tomography. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1216. [PMID: 33178748 PMCID: PMC7607126 DOI: 10.21037/atm-20-4182] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background Pendelluft, defined as asynchronous alveolar ventilation, is caused by different regional time constants or dynamic pleural pressure variations. The aim of the present study was to propose a simple method to evaluate pendelluft based on electrical impedance tomography (EIT). The efficacy of this method was demonstrated in well-known pendelluft scenarios in 6 patients. Methods Two patients with flail chest after accidents, two patients with acute respiratory distress syndrome (ARDS) and two patients with acutely exacerbated obstructive lung disease were prospectively included. EIT measurements were performed before and after surgery (in patients with flail chest, who had video-assisted thoracoscopic surgery with ribs fixation), or at two different levels of positive end-expiratory pressure (PEEP; ARDS patients), or two different time points (obstructive lung disease). Pendelluft was assessed by regional phase shift (defined as time difference between global and regional impedance-time curves) and amplitude differences (defined as the impedance difference between sum of all regional tidal variation and the global tidal variation). Results In patients with flail chest, pendelluft diminished several days after surgery (pendelluft amplitude normalized to tidal impedance variation reduced from 88% to 2% in one patient, 12% to 2% in the other). Increased PEEP reduced the amplitude of pendelluft (from 3% to 0% in one patient, 20% to 2% in the other) but not necessarily the phase shifts (average time differences were <0.1 second for both patients for both ins- and expiration) in ARDS patients. Pendelluft assessment in obstructive lung diseases reflected the change in airway resistance (from 5% to 1% in one patient after broncholytic medication administration, as airway resistance fell from 15 to 11 cmH2O/L/s; from 9% to 35% in the other patient with acute exacerbation, the corresponding airway resistance increased from 15 to 22 cmH2O/L/s). Conclusions The proposed EIT-based method can be used to evaluate the degree of pendelluft in dimension of phase shift and amplitude difference.
Collapse
Affiliation(s)
- Ling Sang
- Department of Critical Care Medicine, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, State Key Lab of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou, China
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Po-Jen Yun
- Division of Thoracic Surgery, Department of Surgery, Tri-Service General Hospital, Taipei
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Feng Fu
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Xiaoqing Liu
- Department of Critical Care Medicine, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, State Key Lab of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou, China
| | - Nanshan Zhong
- Department of Critical Care Medicine, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, State Key Lab of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou, China
| | - Yimin Li
- Department of Critical Care Medicine, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, State Key Lab of Respiratory Diseases, Guangzhou Institute of Respiratory Health, Guangzhou, China
| |
Collapse
|
11
|
Pinto TF, Fagundes Xavier R, Lunardi AC, Marques da Silva CCB, Moriya HT, Lima Vitorasso R, Torsani V, Amato MBP, Stelmach R, Salge JM, Carvalho-Pinto RM, Carvalho CR. Effects of elastic tape on thoracoabdominal mechanics, dyspnea, exercise capacity, and physical activity level in nonobese male subjects with COPD. J Appl Physiol (1985) 2020; 129:492-499. [DOI: 10.1152/japplphysiol.00690.2019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Elastic tape can be used as a new and low-cost intervention to reduce thoracoabdominal asynchrony and sedentary behavior as well as improve exercise capacity and physical activity level in nonobese male subjects with severe-to-very severe chronic obstructive pulmonary disease.
Collapse
Affiliation(s)
- Thiago Fernandes Pinto
- Department of Physical Therapy, Medical School, University of São Paulo, São Paulo, Brazil
| | | | | | | | - Henrique Takachi Moriya
- Biomedical Engineering Laboratory, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Renato Lima Vitorasso
- Biomedical Engineering Laboratory, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Vinicius Torsani
- Pulmonary Division, Heart Institute (InCor), Clinics Hospital, Medical School, University of São Paulo, São Paulo, Brazil
| | - Marcelo Brito Passos Amato
- Pulmonary Division, Heart Institute (InCor), Clinics Hospital, Medical School, University of São Paulo, São Paulo, Brazil
| | - Rafael Stelmach
- Pulmonary Division, Heart Institute (InCor), Clinics Hospital, Medical School, University of São Paulo, São Paulo, Brazil
| | - João Marcos Salge
- Pulmonary Division, Heart Institute (InCor), Clinics Hospital, Medical School, University of São Paulo, São Paulo, Brazil
| | - Regina Maria Carvalho-Pinto
- Pulmonary Division, Heart Institute (InCor), Clinics Hospital, Medical School, University of São Paulo, São Paulo, Brazil
| | - Celso R.F. Carvalho
- Department of Physical Therapy, Medical School, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
12
|
Zhang N, Jiang H, Zhang C, Li Q, Li Y, Zhang B, Deng J, Niu G, Yang B, Frerichs I, Moeller K, Fu F, Zhao Z. The influence of an electrical impedance tomography belt on lung function determined by spirometry in sitting position. Physiol Meas 2020; 41:044002. [PMID: 32160596 DOI: 10.1088/1361-6579/ab7edb] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The aim of the study was to examine whether an electrical impedance tomography (EIT) electrode belt changed the lung function in healthy volunteers and patients with respiratory muscle weakness (RMW) and chronic obstructive pulmonary disease (COPD). APPROACH In total, thirty subjects were included (10 healthy volunteers, 10 subjects with RMW, maximum inspiratory pressure < 40 cmH2O, and 10 COPD, grade I-IV). Spirometry measurements were conducted in a sitting position once a day at similar times on two consecutive days. Slow expiratory vital capacity (VC), forced vital capacity (FVC) and maximum voluntary ventilation (MVV) manoeuvres were performed. On day 1, spirometry was performed without the EIT electrode belt, and on day 2, the belt was attached to the thorax. MAIN RESULTS Lung function was not influenced by the electrode belt in healthy subjects. The test-retest reliability in the healthy group was 0.89, 0.89 and 0.85 for VC, FVC and MVV, respectively. On the other hand, all investigated parameters were significantly decreased in the RMW group (VC, 51.3 ± 18.0 versus 46.5 ± 18.0% predicted, without versus with EIT belt, p< 0.01; FVC, 51.7 ± 19.0 versus 45.8 ± 18.1% predicted, p< 0.01; MVV, 41.0 ± 20.0 versus 38.8 ± 19.6% predicted, p< 0.01). VC and MVV also decreased significantly in the COPD group (VC, 77.4 ± 20.5 versus 74.6 ± 18.8% predicted, p< 0.05; MVV, 57.4 ± 15.7 versus 54.4 ± 12.5% predicted, p< 0.05). SIGNIFICANCE An EIT electrode belt could reduce lung volumes in subjects with pre-existing lung diseases. Comparing lung function acquired with an electrode belt to corresponding values obtained without the belt should be avoided.
Collapse
Affiliation(s)
- Na Zhang
- Department of Respiratory Rehabilitation Center, Beijing Rehabilitation Hospital of Capital Medical University, Xixiazhuang, Badachu, Shijingshan, Beijing 100114, People's Republic of China. Na Zhang and Hongying Jiang contributed equally to this work
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Frerichs I, Vogt B, Wacker J, Paradiso R, Braun F, Rapin M, Caldani L, Chételat O, Weiler N. Multimodal remote chest monitoring system with wearable sensors: a validation study in healthy subjects. Physiol Meas 2020; 41:015006. [DOI: 10.1088/1361-6579/ab668f] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
14
|
Zhao Z, Chang MY, Frerichs I, Zhang JH, Chang HT, Gow CH, Möller K. Regional air trapping in acute exacerbation of obstructive lung diseases measured with electrical impedance tomography: a feasibility study. Minerva Anestesiol 2019; 86:172-180. [PMID: 31808658 DOI: 10.23736/s0375-9393.19.13732-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
BACKGROUND Since bronchial abnormalities often exhibit spatial non-uniformity which may be not correctly assessed by conventional global lung function measures, regional information may help to characterize the disease progress. We hypothesized that regional air trapping during mechanical ventilation could be characterized by regional end-expiratory flow (EEF) derived from electrical impedance tomography (EIT). METHODS Twenty-five patients suffering from chronic obstructive pulmonary disease (COPD grade 3 or 4) or severe asthma with acute exacerbation were examined prospectively. Patients were ventilated under assist-control mode. EIT measurements were conducted before and one hour after inhaled combined corticosteroid and long-acting β2 agonist, on two consecutive days. Regional EEF was calculated as derivative of relative impedance for every image pixel in the lung regions. The results were normalized to global flow values measured by the ventilator. RESULTS Regional and global EEF were highly correlated (P<0.00001) and regional effects of medication and disease progression were visible in the regional EEF maps. The sums of regional EEF in lung regions were 3.8 [2.0, 5.1] and 3.6 [1.9, 4.5] L/min in COPD patients before and after medication (median [lower, upper quartiles]; P=0.37). The corresponding values in asthma patients were 3.0 [2.5, 4.2] and 2.2 [1.7, 3.2] L/min (P<0.05). Histograms of regional EEF showed high spatial heterogeneity of EEF before medication. After one day of treatment, the histograms exhibited less heterogeneous and a decrease in EEF level. CONCLUSIONS Regional EEF characterizes air trapping and intrinsic PEEP, which could provide diagnostic information for monitoring the disease progress during treatment.
Collapse
Affiliation(s)
- Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Mei-Yun Chang
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Inéz Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein Campus, Kiel, Germany
| | - Jia-Hao Zhang
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hou-Tai Chang
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chien-Hung Gow
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan - .,Department of Healthcare Information and Management, Ming-Chuan University, Taoyuan, Taiwan
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
15
|
Barrett NA, Hart N, Camporota L. Assessment of Work of Breathing in Patients with Acute Exacerbations of Chronic Obstructive Pulmonary Disease. COPD 2019; 16:418-428. [PMID: 31694406 DOI: 10.1080/15412555.2019.1681390] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The assessment of the work of breathing (WOB) of patients with acute exacerbations of chronic obstructive pulmonary disease (COPD) is difficult, particularly when the patient first presents with acute hypercapnia and respiratory acidosis. Acute exacerbations of COPD patients are in significant respiratory distress and noninvasive measurements of WOB are easier for the patient to tolerate. Given the interest in using alternative therapies to noninvasive ventilation, such as high flow nasal oxygen therapy or extracorporeal carbon dioxide removal, understanding the physiological changes are key and this includes assessment of WOB. This narrative review considers the role of three different methods of assessing WOB in patients with acute exacerbations of COPD. Esophageal pressure is a very well validated measure of WOB, however the ability of patients with acute exacerbations of COPD to tolerate esophageal tubes is poor. Noninvasive alternative measurements include parasternal electromyography (EMG) and electrical impedance tomography (EIT). EMG is easily applied and is a well validated measure of neural drive but is more likely to be degraded by the electrical environment in intensive care or high dependency. EIT is less well validated as a tool for WOB in COPD but extremely well tolerated by patients. Each of the different methods assess WOB in a different way and have different advantages and disadvantages. For research into therapies treating acute exacerbations of COPD, combinations of EIT, EMG and esophageal pressure are likely to be better than only one of these.
Collapse
Affiliation(s)
- N A Barrett
- Centre for Human & Applied Physiological Sciences (CHAPS), School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, London, United Kingdom.,Department of Critical Care, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - N Hart
- Lane Fox Respiratory Unit, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - L Camporota
- Centre for Human & Applied Physiological Sciences (CHAPS), School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, London, United Kingdom.,Department of Critical Care, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
16
|
Milne S, Huvanandana J, Nguyen C, Duncan JM, Chapman DG, Tonga KO, Zimmermann SC, Slattery A, King GG, Thamrin C. Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in chronic obstructive pulmonary disease. J Appl Physiol (1985) 2019; 127:1441-1452. [PMID: 31556831 DOI: 10.1152/japplphysiol.00304.2019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Pulmonary electrical impedance tomography (EIT) is a functional imaging technique that allows real-time monitoring of ventilation distribution. Ventilation heterogeneity (VH) is a characteristic feature of chronic obstructive pulmonary disease (COPD) and has previously been quantified using features derived from tidal variations in the amplitude of the EIT signal. However, VH may be better described by time-based metrics, the measurement of which is made possible by the high temporal resolution of EIT. We aimed 1) to quantify VH using novel time-based EIT metrics and 2) to determine the physiological relevance of these metrics by exploring their relationships with complex lung mechanics measured by the forced oscillation technique (FOT). We performed FOT, spirometry, and tidal-breathing EIT measurements in 11 healthy controls and 9 volunteers with COPD. Through offline signal processing, we derived 3 features from the impedance-time (Z-t) curve for each image pixel: 1) tE, mean expiratory time; 2) PHASE, mean time difference between pixel and global Z-t curves; and 3) AMP, mean amplitude of Z-t curve tidal variation. Distribution was quantified by the coefficient of variation (CV) and the heterogeneity index (HI). Both CV and HI of the tE and PHASE features were significantly increased in COPD compared with controls, and both related to spirometry and FOT resistance and reactance measurements. In contrast, distribution of the AMP feature showed no relationships with lung mechanics. These novel time-based EIT metrics of VH reflect complex lung mechanics in COPD and have the potential to allow real-time visualization of pulmonary physiology in spontaneously breathing subjects.NEW & NOTEWORTHY Pulmonary electrical impedance tomography (EIT) is a real-time imaging technique capable of monitoring ventilation with exquisite temporal resolution. We report novel, time-based EIT measurements that not only demonstrate ventilation heterogeneity in chronic obstructive pulmonary disease (COPD), but also reflect oscillatory lung mechanics. These EIT measurements are noninvasive, radiation-free, easy to obtain, and provide real-time visualization of the complex pathophysiology of COPD.
Collapse
Affiliation(s)
- Stephen Milne
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine and Health, Central Clinical School, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine and Health, Northern Clinical School, University of Sydney, Sydney, New South Wales, Australia.,Department of Respiratory Medicine, Royal North Shore Hospital, Northern Sydney Local Health District, St. Leonards, New South Wales, Australia.,Centre for Heart Lung Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Jacqueline Huvanandana
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia
| | - Chinh Nguyen
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia
| | - Joseph M Duncan
- Department of Respiratory Medicine, Royal North Shore Hospital, Northern Sydney Local Health District, St. Leonards, New South Wales, Australia
| | - David G Chapman
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia.,Translational Airways Group, School of Life Sciences, University of Technology Sydney, Ultimo, New South Wales, Australia
| | - Katrina O Tonga
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine and Health, Northern Clinical School, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine, the University of New South Wales, Kensington, New South Wales, Australia
| | - Sabine C Zimmermann
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine and Health, Northern Clinical School, University of Sydney, Sydney, New South Wales, Australia.,Department of Respiratory Medicine, Royal North Shore Hospital, Northern Sydney Local Health District, St. Leonards, New South Wales, Australia
| | - Alexander Slattery
- Department of Respiratory Medicine, Royal North Shore Hospital, Northern Sydney Local Health District, St. Leonards, New South Wales, Australia
| | - Gregory G King
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine and Health, Northern Clinical School, University of Sydney, Sydney, New South Wales, Australia.,Department of Respiratory Medicine, Royal North Shore Hospital, Northern Sydney Local Health District, St. Leonards, New South Wales, Australia.,Centre of Excellence in Severe Asthma, New Lambton, New South Wales, Australia
| | - Cindy Thamrin
- Airway Physiology and Imaging Group and Woolcock Emphysema Centre, Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, Australia.,Faculty of Medicine and Health, Central Clinical School, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
17
|
Spinelli E, Mauri T, Fogagnolo A, Scaramuzzo G, Rundo A, Grieco DL, Grasselli G, Volta CA, Spadaro S. Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions. BMC Anesthesiol 2019; 19:140. [PMID: 31390977 PMCID: PMC6686519 DOI: 10.1186/s12871-019-0814-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a non-invasive radiation-free monitoring technique that provides images based on tissue electrical conductivity of the chest. Several investigations applied EIT in the context of perioperative medicine, which is not confined to the intraoperative period but begins with the preoperative assessment and extends to postoperative follow-up. MAIN BODY EIT could provide careful respiratory monitoring in the preoperative assessment to improve preparation for surgery, during anaesthesia to guide optimal ventilation strategies and to monitor the hemodynamic status and in the postoperative period for early detection of respiratory complications. Moreover, EIT could further enhance care of patients undergoing perioperative diagnostic procedures. This narrative review summarizes the latest evidence on the application of this technique to the surgical patient, focusing also on possible future perspectives. CONCLUSIONS EIT is a promising technique for the perioperative assessment of surgical patients, providing tailored adaptive respiratory and haemodynamic monitoring. Further studies are needed to address the current technological limitations, confirm the findings and evaluate which patients can benefit more from this technology.
Collapse
Affiliation(s)
- Elena Spinelli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Tommaso Mauri
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Alberto Fogagnolo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Gaetano Scaramuzzo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Annalisa Rundo
- UOC Anestesia e Rianimazione, Polo ospedaliero Belcolle ASL, Viterbo, Italy
| | - Domenico Luca Grieco
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Fondazione "Policlinico Universitario A. Gemelli", Rome, Italy
| | - Giacomo Grasselli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Carlo Alberto Volta
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Savino Spadaro
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy.
| |
Collapse
|
18
|
Electrical Impedance Tomography for Cardio-Pulmonary Monitoring. J Clin Med 2019; 8:jcm8081176. [PMID: 31394721 PMCID: PMC6722958 DOI: 10.3390/jcm8081176] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/14/2022] Open
Abstract
Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).
Collapse
|
19
|
Barrett NA, Kostakou E, Hart N, Douiri A, Camporota L. Extracorporeal carbon dioxide removal for acute hypercapnic exacerbations of chronic obstructive pulmonary disease: study protocol for a randomised controlled trial. Trials 2019; 20:465. [PMID: 31362776 PMCID: PMC6664508 DOI: 10.1186/s13063-019-3548-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Accepted: 06/29/2019] [Indexed: 01/14/2023] Open
Abstract
Background Chronic obstructive pulmonary disease (COPD) is a common cause of chronic respiratory failure and its course is punctuated by a series of acute exacerbations which commonly lead to hospital admission. Exacerbations are managed through the application of non-invasive ventilation and, when this fails, tracheal intubation and mechanical ventilation. The need for mechanical ventilation significantly increases the risk of death. An alternative therapy, extracorporeal carbon dioxide removal (ECCO2R), has been shown to be efficacious in removing carbon dioxide from the blood; however, its impact on respiratory physiology and patient outcomes has not been explored. Methods/design A randomised controlled open label trial of patients (12 in each arm) with acute exacerbations of COPD at risk of failing conventional therapy (NIV) randomised to either remaining on NIV or having ECCO2R added to NIV with a primary endpoint of time to cessation of NIV. The change in respiratory physiology following the application of ECCO2R and/or NIV will be measured using electrical impedance tomography, oesophageal pressure and parasternal electromyography. Additional outcomes, including patient tolerance, outcomes, need for readmission, changes in blood gases and biochemistry and procedural complications, will be measured. Physiological changes will be compared within one patient over time and between the two groups. Healthcare costs in the UK system will also be compared between the two groups. Discussion COPD is a common disease and exacerbations are a leading cause of hospital admission in the UK and worldwide, with a sizeable mortality. The management of patients with COPD consumes significant hospital and financial resources. This study seeks to understand the feasibility of a novel approach to the management of patients with acute exacerbations of COPD as well as to understand the underlying physiological changes to explain why the approach does or does not assist this patient cohort. Detailed respiratory physiology has not been previously undertaken using this technique and there are no other randomised controlled trials currently in the literature. Trial registration ClinicalTrials.gov, NCT02086084. Electronic supplementary material The online version of this article (10.1186/s13063-019-3548-4) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Nicholas A Barrett
- Department of Critical Care, Guy's and St Thomas' NHS Foundation Trust, Westminster Bridge Rd, London, SE1 7EH, UK. .,Centre for Human & Applied Physiological Sciences (CHAPS), School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, London, UK.
| | - Eirini Kostakou
- Department of Critical Care, Guy's and St Thomas' NHS Foundation Trust, Westminster Bridge Rd, London, SE1 7EH, UK
| | - Nicholas Hart
- Centre for Human & Applied Physiological Sciences (CHAPS), School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, London, UK.,Lane Fox Respiratory Unit, Guy's and St Thomas' NHS Foundation Trust, Westminster Bridge Rd, London, SE1 7EH, UK
| | - Abdel Douiri
- School of Population Health & Environmental Sciences, King's College London, London, WC2R 2LS, UK.,National Institute for Health Research Biomedical Research Centre, Guy's and St Thomas' NHS Trust and King's College London, London, UK
| | - Luigi Camporota
- Department of Critical Care, Guy's and St Thomas' NHS Foundation Trust, Westminster Bridge Rd, London, SE1 7EH, UK.,Centre for Human & Applied Physiological Sciences (CHAPS), School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, London, UK
| |
Collapse
|
20
|
Mauri T, Spinelli E, Dalla Corte F, Scotti E, Turrini C, Lazzeri M, Alban L, Albanese M, Tortolani D, Wang YM, Spadaro S, Zhou JX, Pesenti A, Grasselli G. Noninvasive assessment of airflows by electrical impedance tomography in intubated hypoxemic patients: an exploratory study. Ann Intensive Care 2019; 9:83. [PMID: 31332551 PMCID: PMC6646434 DOI: 10.1186/s13613-019-0560-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 07/17/2019] [Indexed: 11/05/2022] Open
Abstract
Background Noninvasive monitoring of maximal inspiratory and expiratory flows (MIF and MEF, respectively) by electrical impedance tomography (EIT) might enable early recognition of changes in the mechanical properties of the respiratory system due to new conditions or in response to treatments. We aimed to validate EIT-based measures of MIF and MEF against spirometry in intubated hypoxemic patients during controlled ventilation and spontaneous breathing. Moreover, regional distribution of maximal airflows might interact with lung pathology and increase the risk of additional ventilation injury. Thus, we also aimed to describe the effects of mechanical ventilation settings on regional MIF and MEF. Methods We performed a new analysis of data from two prospective, randomized, crossover studies. We included intubated patients admitted to the intensive care unit with acute hypoxemic respiratory failure (AHRF) and acute respiratory distress syndrome (ARDS) undergoing pressure support ventilation (PSV, n = 10) and volume-controlled ventilation (VCV, n = 20). We measured MIF and MEF by spirometry and EIT during six different combinations of ventilation settings: higher vs. lower support during PSV and higher vs. lower positive end-expiratory pressure (PEEP) during both PSV and VCV. Regional airflows were assessed by EIT in dependent and non-dependent lung regions, too. Results MIF and MEF measured by EIT were tightly correlated with those measured by spirometry during all conditions (range of R2 0.629–0.776 and R2 0.606–0.772, respectively, p < 0.05 for all), with clinically acceptable limits of agreement. Higher PEEP significantly improved homogeneity in the regional distribution of MIF and MEF during volume-controlled ventilation, by increasing airflows in the dependent lung regions and lowering them in the non-dependent ones. Conclusions EIT provides accurate noninvasive monitoring of MIF and MEF. The present study also generates the hypothesis that EIT could guide PSV and PEEP settings aimed to increase homogeneity of distending and deflating regional airflows. Electronic supplementary material The online version of this article (10.1186/s13613-019-0560-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy. .,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy
| | - Francesca Dalla Corte
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Eleonora Scotti
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Cecilia Turrini
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Marta Lazzeri
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Laura Alban
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Marco Albanese
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Donatella Tortolani
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Yu-Mei Wang
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.,Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Savino Spadaro
- Department of Morphology, Surgery and Experimental Medicine, Azienda Ospedaliera-Universitaria Arcispedale Sant'Anna, University of Ferrara, Ferrara, Italy
| | - Jian-Xin Zhou
- Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Antonio Pesenti
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Giacomo Grasselli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| |
Collapse
|
21
|
Vogt B, Deuß K, Hennig V, Zhao Z, Lautenschläger I, Weiler N, Frerichs I. Regional lung function in nonsmokers and asymptomatic current and former smokers. ERJ Open Res 2019; 5:00240-2018. [PMID: 31321224 PMCID: PMC6628636 DOI: 10.1183/23120541.00240-2018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 05/01/2019] [Indexed: 11/05/2022] Open
Abstract
Electrical impedance tomography (EIT) is able to detect rapid lung volume changes during breathing. The aim of our observational study was to characterise the heterogeneity of regional ventilation distribution in lung-healthy adults by EIT and to detect the possible impact of tobacco consumption. A total of 219 nonsmokers, asymptomatic ex-smokers and current smokers were examined during forced full expiration using EIT. Forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC were determined in 836 EIT image pixels for the analysis of spatial and temporal ventilation distribution. Coefficients of variation (CVs) of these pixel values were calculated. Histograms and medians of FEV1/FVCEIT and times required to exhale 50%, 75%, 90% of FVCEIT (t50, t75 and t90) were generated. CV of FEV1/FVCEIT distinguished among all groups (mean±sd: nonsmokers 0.43±0.05, ex-smokers 0.52±0.09, smokers 0.62±0.16). Histograms of FEV1/FVCEIT differentiated between nonsmokers and the other groups (p<0.0001). Medians of t50, t75 and t90 showed the lowest values in nonsmokers. Median t90 separated all groups (median (interquartile range): nonsmokers 0.82 (0.67-1.15), ex-smokers 1.41 (1.03-2.21), smokers 1.91 (1.33-3.53)). EIT detects regional ventilation heterogeneity during forced expiration in healthy nonsmokers and its increase in asymptomatic former and current smokers. Therefore, EIT-derived reference values should only be collected from nonsmoking lung-healthy adults.
Collapse
Affiliation(s)
- Barbara Vogt
- Dept of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Kathinka Deuß
- Dept of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Victoria Hennig
- Dept of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Zhanqi Zhao
- Dept of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Dept of Biomedical Engineering, Furtwangen University, Villingen-Schwenningen, Germany
| | - Ingmar Lautenschläger
- Dept of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Norbert Weiler
- Dept of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Inéz Frerichs
- Dept of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
22
|
de Castro Martins T, Sato AK, de Moura FS, de Camargo EDLB, Silva OL, Santos TBR, Zhao Z, Möeller K, Amato MBP, Mueller JL, Lima RG, de Sales Guerra Tsuzuki M. A Review of Electrical Impedance Tomography in Lung Applications: Theory and Algorithms for Absolute Images. ANNUAL REVIEWS IN CONTROL 2019; 48:442-471. [PMID: 31983885 PMCID: PMC6980523 DOI: 10.1016/j.arcontrol.2019.05.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Electrical Impedance Tomography (EIT) is under fast development, the present paper is a review of some procedures that are contributing to improve spatial resolution and material properties accuracy, admitivitty or impeditivity accuracy. A review of EIT medical applications is presented and they were classified into three broad categories: ARDS patients, obstructive lung diseases and perioperative patients. The use of absolute EIT image may enable the assessment of absolute lung volume, which may significantly improve the clinical acceptance of EIT. The Control Theory, the State Observers more specifically, have a developed theory that can be used for the design and operation of EIT devices. Electrode placement, current injection strategy and electrode electric potential measurements strategy should maximize the number of observable and controllable directions of the state vector space. A non-linear stochastic state observer, the Unscented Kalman Filter, is used directly for the reconstruction of absolute EIT images. Historically, difference images were explored first since they are more stable in the presence of modelling errors. Absolute images require more detailed models of contact impedance, stray capacitance and properly refined finite element mesh where the electric potential gradient is high. Parallelization of the forward program computation is necessary since the solution of the inverse problem often requires frequent solutions of the forward problem. Several reconstruction algorithms benefit by the Bayesian inverse problem approach and the concept of prior information. Anatomic and physiologic information are used to form the prior information. An already tested methodology is presented to build the prior probability density function using an ensemble of CT scans and in vivo impedance measurements. Eight absolute EIT image algorithms are presented.
Collapse
Affiliation(s)
| | - André Kubagawa Sato
- Computational Geometry Laboratory, Escola Politécnica da Universidade de São Paulo, Brazil
| | - Fernando Silva de Moura
- Universidade Federal do ABC, Center of Engineering, Modeling and Applied Social Sciences, Brazil
| | | | - Olavo Luppi Silva
- Universidade Federal do ABC, Center of Engineering, Modeling and Applied Social Sciences, Brazil
| | | | - Zhanqi Zhao
- Institute of Technical Medicine, Furtwangen University, Germany
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Knut Möeller
- Institute of Technical Medicine, Furtwangen University, Germany
| | - Marcelo Brito Passos Amato
- Respiratory Intensive Care Unit, Pulmonary Division, Hospital das Clínicas, Universidade de São Paulo, Brazil
| | - Jennifer L Mueller
- Department of Mathematics, and School of Biomedical Engineering, Colorado State University, United States of America
| | - Raul Gonzalez Lima
- Department of Mechanical Engineering, Escola Politécnica da Universidade de São Paulo, Brazil
| | | |
Collapse
|
23
|
Vasques F, Sanderson B, Barrett NA, Camporota L. Monitoring of regional lung ventilation using electrical impedance tomography. Minerva Anestesiol 2019; 85:1231-1241. [PMID: 30945516 DOI: 10.23736/s0375-9393.19.13477-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Among recent lung imaging techniques and devices, electrical impedance tomography (EIT) can provide dynamic information on the distribution regional lung ventilation. EIT images possess a high temporal and functional resolution allowing the visualization of dynamic physiological and pathological changes on a breath-by-breath basis. EIT detects changes in electric impedance (i.e., changes in gas/fluid ratio) and describes them in real time, both visually through images and waveforms, and numerically, allowing the clinician to monitor disease evolution and response to treatment. The use of EIT in clinical practice is supported by several studies demonstrating a good correlation between impedance tomography data and other validated methods of measuring lung volume. In this review, we will provide an overview on the rationale, basic functioning and most common applications of EIT in the management of mechanically ventilated patients.
Collapse
Affiliation(s)
- Francesco Vasques
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK.,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| | - Barnaby Sanderson
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK.,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| | - Nicholas A Barrett
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK.,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| | - Luigi Camporota
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, London, UK - .,Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK
| |
Collapse
|
24
|
Ngo C, Spagnesi S, Munoz C, Lehmann S, Vollmer T, Misgeld B, Leonhardt S. Assessing regional lung mechanics by combining electrical impedance tomography and forced oscillation technique. ACTA ACUST UNITED AC 2019; 63:673-681. [PMID: 28850542 DOI: 10.1515/bmt-2016-0196] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 07/17/2017] [Indexed: 11/15/2022]
Abstract
There is a lack of noninvasive pulmonary function tests which can assess regional information of the lungs. Electrical impedance tomography (EIT) is a radiation-free, non-invasive real-time imaging that provides regional information of ventilation volume regarding the measurement of electrical impedance distribution. Forced oscillation technique (FOT) is a pulmonary function test which is based on the measurement of respiratory mechanical impedance over a frequency range. In this article, we introduce a new measurement approach by combining FOT and EIT, named the oscillatory electrical impedance tomography (oEIT). Our oEIT measurement system consists of a valve-based FOT device, an EIT device, pressure and flow sensors, and a computer fusing the data streams. Measurements were performed on five healthy volunteers at the frequencies 3, 4, 5, 6, 7, 8, 10, 15, and 20 Hz. The measurements suggest that the combination of FOT and EIT is a promising approach. High frequency responses are visible in the derivative of the global impedance index ΔZeit(t,fos). $\Delta {Z_{{\text{eit}}}}(t,{f_{{\text{os}}}}).$ The oEIT signals consist of three main components: forced oscillation, spontaneous breathing, and heart activity. The amplitude of the oscillation component decreases with increasing frequency. The band-pass filtered oEIT signal might be a new tool in regional lung function diagnostics, since local responses to high frequency perturbation could be distinguished between different lung regions.
Collapse
Affiliation(s)
- Chuong Ngo
- Philips Chair of Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Sarah Spagnesi
- Philips Chair of Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Carlos Munoz
- Philips Chair of Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Sylvia Lehmann
- Department of Pediatric Pulmonology, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074 Aachen, Germany
| | - Thomas Vollmer
- Philips GmbH Innovative Technologies Aachen, Pauwelsstr. 17, 52074 Aachen, Germany
| | - Berno Misgeld
- Philips Chair of Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Steffen Leonhardt
- Philips Chair of Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| |
Collapse
|
25
|
Rapin M, Braun F, Adler A, Wacker J, Frerichs I, Vogt B, Chetelat O. Wearable Sensors for Frequency-Multiplexed EIT and Multilead ECG Data Acquisition. IEEE Trans Biomed Eng 2019; 66:810-820. [DOI: 10.1109/tbme.2018.2857199] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
26
|
Zhang C, Dai M, Liu W, Bai X, Wu J, Xu C, Xia J, Fu F, Shi X, Dong X, Jin F, You F. Global and regional degree of obstruction determined by electrical impedance tomography in patients with obstructive ventilatory defect. PLoS One 2018; 13:e0209473. [PMID: 30571739 PMCID: PMC6301672 DOI: 10.1371/journal.pone.0209473] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 12/06/2018] [Indexed: 11/19/2022] Open
Abstract
Background Electrical impedance tomography is a continuous imaging method capable of measuring lung volume changes. The purpose of this study was to examine whether EIT was capable of evaluating the degree of obstructive ventilatory defect (OVD) on the global and regional level. Methods 41 healthy subjects with no lung diseases and 67 subjects suffering from obstructive lung diseases were examined using EIT and spirometry during forced vital capacity (FVC) maneuver. The subjects were divided into control group (n = 41), early airway obstruction group (n = 26), mild group (n = 17), moderate group (n = 16) and severe group (n = 8) according to the degree of obstruction. Forced expiratory volume in 1 second (FEV1) and FEV1/FVC were determined by EIT. The mode index (MI) was proposed to evaluate the degree of global and regional obstruction; the effectiveness of MI was validated by evaluating posture related change of lung emptying capacity in sitting and supine postures; the degree of regional obstruction was determined according to the cut-off values of MI obtained from receiver operating characteristic (ROC) analysis; regional obstruction was located in the four-quadrant region of interest (ROI) and the contour-map ROI with contour lines at the cut-off values of MI. Results Significant differences were found between different groups (P<0.05) and the global MI was 0.93±0.03, 0.86±0.05, 0.81±0.09, 0.73±0.09 and 0.60±0.11 (mean ±SD), respectively. The cut-off MI value was 0.90, 0.83, 0.77, and 0.65, respectively. Conclusion The results indicated the potential of EIT to evaluate the degree of obstruction in patients with obstructive ventilatory defect on the global and regional level.
Collapse
Affiliation(s)
- Chao Zhang
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China.,Medical Engineering Section, General Hospital of Shenyang Military Region, Shenyang, Liaoning, China
| | - Meng Dai
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Wei Liu
- Department of respiratory medicine, Tangdu Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Xiaohui Bai
- The Fifth People's Hospital of Baoji City, Baoji, Shaanxi, China
| | - Jiaming Wu
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China.,Department of Medical Technology, Bethune Military Medical NCO Academy of PLA, Shijiazhuang, Hebei, China
| | - Canhua Xu
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Junying Xia
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Feng Fu
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Xuetao Shi
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Xiuzhen Dong
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Faguang Jin
- Department of respiratory medicine, Tangdu Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Fusheng You
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, China
| |
Collapse
|
27
|
Karagiannidis C, Waldmann AD, Róka PL, Schreiber T, Strassmann S, Windisch W, Böhm SH. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2018; 22:221. [PMID: 30236123 PMCID: PMC6148957 DOI: 10.1186/s13054-018-2137-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Accepted: 07/27/2018] [Indexed: 01/17/2023]
Abstract
Background Electrical impedance tomography (EIT) has been used to guide mechanical ventilation in ICU patients with lung collapse. Its use in patients with obstructive pulmonary diseases has been rare since obstructions could not be monitored on a regional level at the bedside. The current study therefore determines breath-by-breath regional expiratory time constants in intubated patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). Methods Expiratory time constants calculated from the global impedance EIT signal were compared to the pneumatic volume signals measured with an electronic pneumotachograph. EIT-derived expiratory time constants were additionally determined on a regional and pixelwise level. However, regional EIT signals on a single pixel level could in principle not be compared with similar pneumatic changes since these measurements cannot be obtained in patients. For this study, EIT measurements were conducted in 14 intubated patients (mean Simplified Acute Physiology Score II (SAPS II) 35 ± 10, mean time on invasive mechanical ventilation 36 ± 26 days) under four different positive end-expiratory pressure (PEEP) levels ranging from 10 to 17 cmH2O. Only patients with moderate-severe ARDS or COPD exacerbation were included into the study, preferentally within the first days following intubation. Results Spearman’s correlation coefficient for comparison between EIT-derived time constants and those from flow/volume curves was between 0.78 for tau (τ) calculated from the global impedance signal up to 0.83 for the mean of all pixelwise calculated regional impedance changes over the entire PEEP range. Furthermore, Bland-Altman analysis revealed a corresponding bias of 0.02 and 0.14 s within the limits of agreement ranging from − 0.50 to 0.65 s for the aforementioned calculation methods. In addition, exemplarily in patients with moderate-severe ARDS or COPD exacerbation, different PEEP levels were shown to have an influence on the distribution pattern of regional time constants. Conclusions EIT-based determination of breath-by-breath regional expiratory time constants is technically feasible, reliable and valid in invasively ventilated patients with severe respiratory failure and provides a promising tool to individually adjust mechanical ventilation in response to the patterns of regional airflow obstruction. Trial registration German Trial Register DRKS 00011650, registered 01/31/17. Electronic supplementary material The online version of this article (10.1186/s13054-018-2137-3) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Christian Karagiannidis
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, D-51109, Cologne, Germany.
| | - Andreas D Waldmann
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, D-51109, Cologne, Germany.,Swisstom AG, Schulstrasse 1, 7302, Landquart, Switzerland
| | - Péter L Róka
- Budapest University of Technology and Economics, Budapest, Hungary
| | - Tina Schreiber
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, D-51109, Cologne, Germany
| | - Stephan Strassmann
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, D-51109, Cologne, Germany
| | - Wolfram Windisch
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, D-51109, Cologne, Germany
| | - Stephan H Böhm
- Klinik und Poliklinik für Anästhesiologie und Intensivtherapie, Universitätsmedizin Rostock, Schillingallee 35, D-18057, Rostock, Germany
| |
Collapse
|
28
|
Ngo C, Dippel F, Tenbrock K, Leonhardt S, Lehmann S. Flow-volume loops measured with electrical impedance tomography in pediatric patients with asthma. Pediatr Pulmonol 2018; 53:636-644. [PMID: 29405616 DOI: 10.1002/ppul.23962] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 01/15/2018] [Indexed: 12/16/2022]
Abstract
BACKGROUND Electrical impedance tomography (EIT) provides information on global and regional ventilation during tidal breathing and mechanical ventilation. During forced expiration maneuvers, the linearity of EIT and spirometric data has been documented in healthy persons. The present study investigates the potential diagnostic use of EIT in pediatric patients with asthma. METHODS EIT and spirometry were performed in 58 children with asthma (average age ± SD: 11.86 ± 3.13 years), and 58 healthy controls (average age ± SD: 12.12 ± 2.9 years). The correlation between EIT data and simultaneously acquired spirometric data were tested for FEV1, FEV0.5 , MEF75 , MEF50 , and MEF25 . Binary classification tests were performed for the EIT-derived Tiffeneau index FEV1 /FVC and the bronchodilator test index ΔFEV1 . Average flow-volume (FV) loops were generated for patients with pathologic spirometry to demonstrate the feasibility of EIT for graphic diagnosis of asthma. RESULTS Spirometry and global EIT-based FV loops showed a strong correlation (P < 0.001, r > 0.9 in FEV1 and FEV0.5 ). In all criteria, the binary classification tests yielded high specificity (>93%), a high positive predictive value (≥75%) and a high negative predictive value (>80%), while sensitivity was higher in ΔFEV1 (86.67%) and lower in FEV1 /FVC (25% and 35.29%). A typical concave shape of the EIT-derived average FV loops was observed for asthmatic children with improvement after bronchospasmolysis. CONCLUSIONS Global FV loops derived from EIT correlate well with spirometry. Positive bronchospasmolysis can be observed in EIT-derived FV loops. Flow-volume loops originated from EIT have a potential to visualize pulmonary function.
Collapse
Affiliation(s)
- Chuong Ngo
- Philips Chair for Medical Information Technology, RWTH Aachen, Aachen, Germany
| | - Falk Dippel
- Philips Chair for Medical Information Technology, RWTH Aachen, Aachen, Germany
| | - Klaus Tenbrock
- Department of Pediatric Pulmonology, RWTH Aachen University Hospital, Aachen, Germany
| | - Steffen Leonhardt
- Philips Chair for Medical Information Technology, RWTH Aachen, Aachen, Germany
| | - Sylvia Lehmann
- Department of Pediatric Pulmonology, RWTH Aachen University Hospital, Aachen, Germany
| |
Collapse
|
29
|
Krueger-Ziolek S, Schullcke B, Gong B, Müller-Lisse U, Moeller K. EIT based pulsatile impedance monitoring during spontaneous breathing in cystic fibrosis. Physiol Meas 2018; 38:1214-1225. [PMID: 28530203 DOI: 10.1088/1361-6579/aa69d5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Evaluating the lung function in patients with obstructive lung disease by electrical impedance tomography (EIT) usually requires breathing maneuvers containing deep inspirations and forced expirations. Since these maneuvers strongly depend on the patient's co-operation and health status, normal tidal breathing was investigated in an attempt to develop continuous maneuver-free measurements. APPROACH Ventilation related and pulsatile impedance changes were systematically analyzed during normal tidal breathing in 12 cystic fibrosis (CF) patients and 12 lung-healthy controls (HL). Tidal breaths were subdivided into three inspiratory (In1, In2, In3) and three expiratory (Ex1, Ex2, Ex3) sections of the same amplitude of global impedance change. Maximal changes of the ventilation and the pulsatile impedance signal occurring during these sections were determined (▵I V and ▵I P). Differences in ▵I V and ▵I P among sections were ascertained in relation to the first inspiratory section. In addition, ▵I V/▵I P was calculated for each section. MAIN RESULTS Medians of changes in ▵I V were <0.05% in all sections for both subject groups. Both groups showed a similar pattern of ▵I P changes during tidal breathing. Changes in ▵I P first decreased during inspiration (In2), then increased towards the end of inspiration (In3) and reached a maximum at the beginning of expiration (Ex1). During the last two sections of expiration (Ex2, Ex3) ▵I P changes decreased. The CF patients showed higher variations in ▵I P changes compared to the controls (CF: -426.5%, HL: -158.1%, coefficient of variation). Furthermore, ▵I V/▵I P significantly differed between expiratory sections for the CF patients (Ex1-Ex2, p < 0.01; Ex1-Ex3, p < 0.001; Ex2-Ex3, p < 0.05), but not for the controls. No significant differences in ▵I V/▵I P between inspiratory sections were determined for both groups. SIGNIFICANCE Differences in ▵I P changes and in ▵I V/▵I P between both subject groups were speculated to be caused by higher breathing efforts of the CF patients due to airway obstruction leading to higher intrathoracic pressures, and thus to greater changes in lung perfusion.
Collapse
Affiliation(s)
- Sabine Krueger-Ziolek
- Institute of Technical Medicine, Furtwangen University, Jakob-Kienzle-Straße 17, 78054 Villingen-Schwenningen, Germany. Department of Radiology, LMU University of Munich, Ziemssenstrasse 1, 80336 Munich, Germany3
| | | | | | | | | |
Collapse
|
30
|
Ngo C, Leonhardt S, Zhang T, Lüken M, Misgeld B, Vollmer T, Tenbrock K, Lehmann S. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers. Physiol Meas 2016; 38:77-86. [PMID: 28004642 DOI: 10.1088/1361-6579/38/1/77] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Electrical impedance tomography (EIT) provides global and regional information about ventilation by means of relative changes in electrical impedance measured with electrodes placed around the thorax. In combination with lung function tests, e.g. spirometry and body plethysmography, regional information about lung ventilation can be achieved. Impedance changes strictly correlate with lung volume during tidal breathing and mechanical ventilation. Initial studies presumed a correlation also during forced expiration maneuvers. To quantify the validity of this correlation in extreme lung volume changes during forced breathing, a measurement system was set up and applied on seven lung-healthy volunteers. Simultaneous measurements of changes in lung volume using EIT imaging and pneumotachography were obtained with different breathing patterns. Data was divided into a synchronizing phase (spontaneous breathing) and a test phase (maximum effort breathing and forced maneuvers). The EIT impedance changes correlate strictly with spirometric data during slow breathing with increasing and maximum effort ([Formula: see text]) and during forced expiration maneuvers ([Formula: see text]). Strong correlations in spirometric volume parameters [Formula: see text] ([Formula: see text]), [Formula: see text]/FVC ([Formula: see text]), and flow parameters PEF, [Formula: see text], [Formula: see text], [Formula: see text] ([Formula: see text]) were observed. According to the linearity during forced expiration maneuvers, EIT can be used during pulmonary function testing in combination with spirometry for visualisation of regional lung ventilation.
Collapse
Affiliation(s)
- Chuong Ngo
- Philips Chair of Medical Information Technology, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Frerichs I, Amato MBP, van Kaam AH, Tingay DG, Zhao Z, Grychtol B, Bodenstein M, Gagnon H, Böhm SH, Teschner E, Stenqvist O, Mauri T, Torsani V, Camporota L, Schibler A, Wolf GK, Gommers D, Leonhardt S, Adler A. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax 2016; 72:83-93. [PMID: 27596161 PMCID: PMC5329047 DOI: 10.1136/thoraxjnl-2016-208357] [Citation(s) in RCA: 474] [Impact Index Per Article: 59.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 07/12/2016] [Accepted: 07/16/2016] [Indexed: 11/04/2022]
Abstract
Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Marcelo B P Amato
- Pulmonary Division, Heart Institute (InCor), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Anton H van Kaam
- Department of Neonatology, Emma Children's Hospital, Academic Medical Center, Amsterdam, The Netherlands
| | - David G Tingay
- Neonatal Research, Murdoch Childrens Research Institute, Parkville, Victoria, Australia
| | - Zhanqi Zhao
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Bartłomiej Grychtol
- Fraunhofer Project Group for Automation in Medicine and Biotechnology PAMB, Mannheim, Germany
| | - Marc Bodenstein
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Hervé Gagnon
- Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada
| | | | | | - Ola Stenqvist
- Department of Anesthesiology and Intensive Care Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Vinicius Torsani
- Pulmonary Division, Heart Institute (InCor), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Luigi Camporota
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Andreas Schibler
- Paediatric Critical Care Research Group, Mater Research University of Queensland, South Brisbane, Australia
| | - Gerhard K Wolf
- Children's Hospital Traunstein, Ludwig Maximilian's University, Munich, Germany
| | - Diederik Gommers
- Department of Adult Intensive Care, Erasmus MC, Rotterdam, The Netherlands
| | - Steffen Leonhardt
- Philips Chair for Medical Information Technology, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Andy Adler
- Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada
| | | |
Collapse
|