Herrmann J, Kollisch-Singule M, Satalin J, Nieman GF, Kaczka DW. Assessment of Heterogeneity in Lung Structure and Function During Mechanical Ventilation: A Review of Methodologies. JOURNAL OF ENGINEERING AND SCIENCE IN MEDICAL DIAGNOSTICS AND THERAPY 2022; 5:040801. [PMID: 35832339 PMCID: PMC9132008 DOI: 10.1115/1.4054386] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 04/13/2022] [Indexed: 06/15/2023]
Abstract
The mammalian lung is characterized by heterogeneity in both its structure and function, by incorporating an asymmetric branching airway tree optimized for maintenance of efficient ventilation, perfusion, and gas exchange. Despite potential benefits of naturally occurring heterogeneity in the lungs, there may also be detrimental effects arising from pathologic processes, which may result in deficiencies in gas transport and exchange. Regardless of etiology, pathologic heterogeneity results in the maldistribution of regional ventilation and perfusion, impairments in gas exchange, and increased work of breathing. In extreme situations, heterogeneity may result in respiratory failure, necessitating support with a mechanical ventilator. This review will present a summary of measurement techniques for assessing and quantifying heterogeneity in respiratory system structure and function during mechanical ventilation. These methods have been grouped according to four broad categories: (1) inverse modeling of heterogeneous mechanical function; (2) capnography and washout techniques to measure heterogeneity of gas transport; (3) measurements of heterogeneous deformation on the surface of the lung; and finally (4) imaging techniques used to observe spatially-distributed ventilation or regional deformation. Each technique varies with regard to spatial and temporal resolution, degrees of invasiveness, risks posed to patients, as well as suitability for clinical implementation. Nonetheless, each technique provides a unique perspective on the manifestations and consequences of mechanical heterogeneity in the diseased lung.
Collapse
Affiliation(s)
- Jacob Herrmann
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52242
| | | | - Joshua Satalin
- Department of Surgery, SUNY Upstate Medical University, Syracuse, NY 13210
| | - Gary F. Nieman
- Department of Surgery, SUNY Upstate Medical University, Syracuse, NY 13210
| | - David W. Kaczka
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52242; Department of Anesthesia, University of Iowa, Iowa City, IA 52242; Department of Radiology, University of Iowa, Iowa City, IA 52242
| |
Collapse
|
2
|
Cruz AF, Herrmann J, Carvalho CRR, Kaczka DW. A comparison of endotracheal tube compensation techniques for the measurement of respiratory mechanical impedance at low frequencies. J Clin Monit Comput 2022; 36:1461-1477. [PMID: 34910285 PMCID: PMC9198108 DOI: 10.1007/s10877-021-00788-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Accepted: 12/01/2021] [Indexed: 11/29/2022]
Abstract
Measurement of respiratory impedance ([Formula: see text]) in intubated patients requires accurate compensation for pressure losses across the endotracheal tube (ETT). In this study, we compared time-domain (TD), frequency-domain (FD) and combined time-/frequency-domain (FT) methods for ETT compensation. We measured total impedance ([Formula: see text]) of a test lung in series with three different ETT sizes, as well as in three intubated porcine subjects. Pressure measurement at the distal end of the ETT was used to determine the true [Formula: see text]. For TD compensation, pressure distal to the ETT was obtained based on its resistive and inertial properties, and the corresponding [Formula: see text] was estimated. For FD compensation, impedance of the isolated ETT was obtained from oscillatory flow and pressure waveforms, and then subtracted from [Formula: see text]. For TF compensation, the nonlinear resistive properties of the ETT were subtracted from the proximal pressure measurement, from which the linear resistive and inertial ETT properties were removed in the frequency-domain to obtain [Formula: see text]. The relative root mean square error between the actual and estimated [Formula: see text] ([Formula: see text]) showed that TD compensation yielded the least accurate estimates of [Formula: see text] for the in vitro experiments, with small deviations observed at higher frequencies. The FD and TF compensations yielded estimates of [Formula: see text] with similar accuracies. For the porcine subjects, no significant differences were observed in [Formula: see text] across compensation methods. FD and TF compensation of the ETT may allow for accurate oscillometric estimates of [Formula: see text] in intubated subjects, while avoiding the difficulties associated with direct tracheal pressure measurement.
Collapse
Affiliation(s)
- Andrea F Cruz
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Heart Institute (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, São Paulo, Brazil
- Department of Anesthesia, University of Iowa, Iowa City, IA, USA
| | - Jacob Herrmann
- Department of Anesthesia, University of Iowa, Iowa City, IA, USA
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA
| | - Carlos R R Carvalho
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Heart Institute (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, São Paulo, Brazil
| | - David W Kaczka
- Department of Anesthesia, University of Iowa, Iowa City, IA, USA.
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA.
- Department of Radiology, University of Iowa, Iowa City, IA, USA.
| |
Collapse
|
3
|
Dong SJ, Wang L, Chitano P, Coxson HO, Paré PD, Seow CY. Airway diameter at different transpulmonary pressures in ex vivo sheep lungs: Implications for deep-inspiration-induced bronchodilation and bronchoprotection. Am J Physiol Lung Cell Mol Physiol 2021; 321:L663-L674. [PMID: 34287071 DOI: 10.1152/ajplung.00208.2021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Deep inspiration (DI)-induced bronchodilation is the first line of defense against bronchoconstriction in healthy subjects. A hallmark of asthma is the lack of this beneficial effect of DI. The mechanism underlying the bronchodilatory effect of DI is not clear. Understanding the mechanism will help us unravel the mystery of asthma pathophysiology. It has been postulated that straining airway smooth muscle (ASM) during a DI could lead to bronchodilation and bronchoprotection. The hypothesis is currently under debate, and a central question is whether ASM is sufficiently stretched during a DI for its contractility to be compromised. Besides bronchoconstriction, another contributor to lung resistance is airway heterogeneity. The present study examines changes in airway diameter and heterogeneity at different lung volumes. Freshly explanted sheep lungs were used in plethysmographic measurements of lung resistance and elastance at different lung volumes while the airway dimensions were measured by computed tomography (CT). The change in airway diameter informed by CT measurements was applied to isolated airway ring preparations to determine the strain-induced loss of ASM contractility. We found that changing the transpulmonary pressure from 5 to 30 cmH2O led to a 51%-increase in lung volume, accompanied by a 46%-increase in the airway diameter with no change in airway heterogeneity. When comparable airway strains measured in the whole lung were applied to isolated airway rings in either relaxed or contracted state, a significant loss of ASM contractility was observed, suggesting that DI-induced bronchodilation and bronchoprotection can result from strain-induced loss of ASM contractility.
Collapse
Affiliation(s)
- Shou-Jin Dong
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada.,Respiratory Department, Chengdu First People's Hospital, Chengdu, China
| | - Lu Wang
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada
| | - Pasquale Chitano
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada
| | - Harvey O Coxson
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada
| | - Peter D Paré
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada.,Department of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Chun Y Seow
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada.,Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
4
|
Phung TKN, Sinclair SE, Makena P, Molthen RC, Waters CM. Dynamic airway constriction in rats: heterogeneity and response to deep inspiration. Am J Physiol Lung Cell Mol Physiol 2019; 317:L39-L48. [PMID: 31017015 DOI: 10.1152/ajplung.00050.2019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Airway narrowing due to hyperresponsiveness severely limits gas exchange in patients with asthma. Imaging studies in humans and animals have shown that bronchoconstriction causes patchy patterns of ventilation defects throughout the lungs, and several computational models have predicted that these regions are due to constriction of smaller airways. However, these imaging approaches are often limited in their ability to capture dynamic changes in small airways, and the patterns of constriction are heterogeneous. To directly investigate regional variations in airway narrowing and the response to deep inspirations (DIs), we utilized tantalum dust and microfocal X-ray imaging of rat lungs to obtain dynamic images of airways in an intact animal model. Airway resistance was simultaneously measured using the flexiVent system. Custom-developed software was used to track changes in airway diameters up to generation 19 (~0.3-3 mm). Changes in diameter during bronchoconstriction were then measured in response to methacholine (MCh) challenge. In contrast with the model predictions, we observed significantly greater percent constriction in larger airways in response to MCh challenge. Although there was a dose-dependent increase in total respiratory resistance with MCh, the percent change in airway diameters was similar for increasing doses. A single DI following MCh caused a significant reduction in resistance but did not cause a significant increase in airway diameters. Multiple DIs did, however, cause significant increases in airway diameters. These measurements allowed us to directly quantify dynamic changes in airways during bronchoconstriction and demonstrated greater constriction in larger airways.
Collapse
Affiliation(s)
- Thien-Khoi N Phung
- Department of Physiology, University of Tennessee Health Science Center , Memphis, Tennessee
| | - Scott E Sinclair
- Department of Physiology, University of Tennessee Health Science Center , Memphis, Tennessee.,Department of Medicine, University of Tennessee Health Science Center , Memphis, Tennessee
| | - Patrudu Makena
- Department of Medicine, University of Tennessee Health Science Center , Memphis, Tennessee
| | - Robert C Molthen
- Department of Medicine, Medical College of Wisconsin , Milwaukee, Wisconsin
| | - Christopher M Waters
- Department of Physiology, University of Tennessee Health Science Center , Memphis, Tennessee.,Department of Medicine, University of Tennessee Health Science Center , Memphis, Tennessee.,Department of Physiology and Saha Cardiovascular Research Center, University of Kentucky , Lexington, Kentucky
| |
Collapse
|
5
|
Mondoñedo JR, McNeil JS, Herrmann J, Simon BA, Kaczka DW. Targeted Versus Continuous Delivery of Volatile Anesthetics During Cholinergic Bronchoconstriction. JOURNAL OF ENGINEERING AND SCIENCE IN MEDICAL DIAGNOSTICS AND THERAPY 2018; 1:031003. [PMID: 31106293 PMCID: PMC6516463 DOI: 10.1115/1.4040001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 04/13/2018] [Indexed: 11/08/2022]
Abstract
Volatile anesthetics have been shown to reduce lung resistance through dilation of constricted airways. In this study, we hypothesized that that diffusion of inhaled anesthetics from airway lumen to smooth muscle would yield significant bronchodilation in vivo, and systemic recirculation would not be necessary to reduce lung resistance (RL ) and elastance (EL ) during sustained bronchoconstriction. To test this hypothesis, we designed a delivery system for precise timing of inhaled volatile anesthetics during the course of a positive pressure breath. We compared changes in RL , EL , and anatomic dead space (VD ) in canines (N=5) during pharmacologically-induced bronchoconstriction with intravenous methacholine, and following treatments with: 1) targeted anesthetic delivery to VD ; and 2) continuous anesthetic delivery throughout inspiration. Both sevoflurane and isoflurane were used during each delivery regimen. Compared to continuous delivery, targeted delivery resulted in significantly lower doses of delivered anesthetic and decreased end-expiratory concentrations. However, we did not detect significant reductions in RL or EL for either anesthetic delivery regimen. This lack of response may have resulted from an insufficient dose of the anesthetic to cause bronchodilation, or from the preferential distribution of air flow with inhaled anesthetic delivery to less constricted, unobstructed regions of the lung, thereby enhancing airway heterogeneity and increasing apparent RL and EL .
Collapse
Affiliation(s)
- Jarred R. Mondoñedo
- Department of Biomedical Engineering,
School of Medicine,
Boston University,
Boston, MA 02215
| | - John S. McNeil
- Department of Anesthesiology,
University of Virginia,
Charlottesville, VA 22903
| | - Jacob Herrmann
- Department of Anesthesiology;Department of Biomedical Engineering,
University of Iowa,
Iowa City, IA 52242
| | - Brett A. Simon
- Department of Anesthesiology
and Critical Care Medicine;
Department of Surgery,
Memorial Sloan Kettering Cancer Center,
New York, NY 10065
| | - David W. Kaczka
- Department of Anesthesiology, Biomedical
Engineering, and Radiology;
Department of Biomedical Engineering;
Department of Radiology,
University of Iowa Hospitals and Clinics,
Iowa City, IA 52242
e-mail:
| |
Collapse
|
6
|
Glapiński J, Mroczka J, Polak AG. Analysis of the method for ventilation heterogeneity assessment using the Otis model and forced oscillations. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2015; 122:330-340. [PMID: 26363677 DOI: 10.1016/j.cmpb.2015.08.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 08/24/2015] [Accepted: 08/27/2015] [Indexed: 06/05/2023]
Abstract
Increased heterogeneity of the lung disturbs pulmonary gas exchange. During bronchoconstriction, inflammation of lung parenchyma or acute respiratory distress syndrome, inhomogeneous lung ventilation can become bimodal and increase the risk of ventilator-induced lung injury during mechanical ventilation. A simple index sensitive to ventilation heterogeneity would be very useful in clinical practice. In the case of bimodal ventilation, the index (H) can be defined as the ratio between the longer and shorter time constant characterising regions of contrary mechanical properties. These time constants can be derived from the Otis model fitted to input impedance (Zin) measured using forced oscillations. In this paper we systematically investigated properties of the aforementioned approach. The research included both numerical simulations and real experiments with a dual-lung simulator. Firstly, a computational model mimicking the physical simulator was derived and then used as a forward model to generate synthetic flow and pressure signals. These data were used to calculate the input impedance and then the Otis inverse model was fitted to Zin by means of the Levenberg-Marquardt (LM) algorithm. Finally, the obtained estimates of model parameters were used to compute H. The analysis of the above procedure was performed in the frame of Monte Carlo simulations. For each selected value of H, forward simulations with randomly chosen lung parameters were repeated 1000 times. Resulting signals were superimposed by additive Gaussian noise. The estimated values of H properly indicated the increasing level of simulated inhomogeneity, however with underestimation and variation increasing with H. The main factor responsible for the growing estimation bias was the fixed starting vector required by the LM algorithm. Introduction of a correction formula perfectly reduced this systematic error. The experimental results with the dual-lung simulator confirmed potential of the proposed procedure to properly deduce the lung heterogeneity level. We conclude that the heterogeneity index H can be used to assess bimodal ventilation imbalances in cases when this phenomenon dominates lung properties, however future analyses, including the impact of lung tissue viscoelasticity and distributed airway or tissue inhomogeneity on H estimates, as well as studies in the time domain, are advisable.
Collapse
Affiliation(s)
- Jarosław Glapiński
- Chair of Electronic and Photonic Metrology, Wrocław University of Technology, Wrocław, Poland.
| | - Janusz Mroczka
- Chair of Electronic and Photonic Metrology, Wrocław University of Technology, Wrocław, Poland
| | - Adam G Polak
- Chair of Electronic and Photonic Metrology, Wrocław University of Technology, Wrocław, Poland
| |
Collapse
|
7
|
Pellegrino R, Gobbi A, Antonelli A, Torchio R, Gulotta C, Pellegrino GM, Dellacà R, Hyatt RE, Brusasco V. Ventilation heterogeneity in obesity. J Appl Physiol (1985) 2014; 116:1175-81. [PMID: 24651986 DOI: 10.1152/japplphysiol.01339.2013] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Obesity is associated with important decrements in lung volumes. Despite this, ventilation remains normally or near normally distributed at least for moderate decrements in functional residual capacity (FRC). We tested the hypothesis that this is because maximum flow increases presumably as a result of an increased lung elastic recoil. Forced expiratory flows corrected for thoracic gas compression volume, lung volumes, and forced oscillation technique at 5-11-19 Hz were measured in 133 healthy subjects with a body mass index (BMI) ranging from 18 to 50 kg/m(2). Short-term temporal variability of ventilation heterogeneity was estimated from the interquartile range of the frequency distribution of the difference in inspiratory resistance between 5 and 19 Hz (R5-19_IQR). FRC % predicted negatively correlated with BMI (r = -0.72, P < 0.001) and with an increase in slope of either maximal (r = -0.34, P < 0.01) or partial flow-volume curves (r = -0.30, P < 0.01). Together with a slight decrease in residual volume, this suggests an increased lung elastic recoil. Regression analysis of R5-19_IQR against FRC % predicted and expiratory reserve volume (ERV) yielded significantly higher correlation coefficients by nonlinear than linear fitting models (r(2) = 0.40 vs. 0.30 for FRC % predicted and r(2) = 0.28 vs. 0.19 for ERV). In conclusion, temporal variability of ventilation heterogeneities increases in obesity only when FRC falls approximately below 65% of predicted or ERV below 0.6 liters. Above these thresholds distribution is quite well preserved presumably as a result of an increase in lung recoil.
Collapse
Affiliation(s)
- Riccardo Pellegrino
- Allergologia e Fisiopatologia Respiratoria, ASO S. Croce e Carle, Cuneo, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|