1
|
Chen J, Finlay WH, Vehring R, Martin AR. Characterizing regional drug delivery within the nasal airways. Expert Opin Drug Deliv 2024; 21:537-551. [PMID: 38568159 DOI: 10.1080/17425247.2024.2336494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 03/26/2024] [Indexed: 05/18/2024]
Abstract
INTRODUCTION The nose has been receiving increased attention as a route for drug delivery. As the site of deposition constitutes the first point of contact of the body with the drug, characterization of the regional deposition of intranasally delivered droplets or particles is paramount to formulation and device design of new products. AREAS COVERED This review article summarizes the recent literature on intranasal regional drug deposition evaluated in vivo, in vitro and in silico, with the aim of correlating parameters measured in vitro with formulation and device performance. We also highlight the relevance of regional deposition to two emerging applications: nose-to-brain drug delivery and intranasal vaccines. EXPERT OPINION As in vivo studies of deposition can be costly and time-consuming, researchers have often turned to predictive in vitro and in silico models. Variability in deposition is high due in part to individual differences in nasal geometry, and a complete predictive model of deposition based on spray characteristics remains elusive. Carefully selected or idealized geometries capturing population average deposition can be useful surrogates to in vivo measurements. Continued development of in vitro and in silico models may pave the way for development of less variable and more effective intranasal drug products.
Collapse
Affiliation(s)
- John Chen
- Access to Advanced Health Institute, Seattle, WA, USA
| | - Warren H Finlay
- Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Reinhard Vehring
- Access to Advanced Health Institute, Seattle, WA, USA
- Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Andrew R Martin
- Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
2
|
Johnsen SG. Computational Rhinology: Unraveling Discrepancies between In Silico and In Vivo Nasal Airflow Assessments for Enhanced Clinical Decision Support. Bioengineering (Basel) 2024; 11:239. [PMID: 38534513 DOI: 10.3390/bioengineering11030239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/09/2024] [Accepted: 02/17/2024] [Indexed: 03/28/2024] Open
Abstract
Computational rhinology is a specialized branch of biomechanics leveraging engineering techniques for mathematical modelling and simulation to complement the medical field of rhinology. Computational rhinology has already contributed significantly to advancing our understanding of the nasal function, including airflow patterns, mucosal cooling, particle deposition, and drug delivery, and is foreseen as a crucial element in, e.g., the development of virtual surgery as a clinical, patient-specific decision support tool. The current paper delves into the field of computational rhinology from a nasal airflow perspective, highlighting the use of computational fluid dynamics to enhance diagnostics and treatment of breathing disorders. This paper consists of three distinct parts-an introduction to and review of the field of computational rhinology, a review of the published literature on in vitro and in silico studies of nasal airflow, and the presentation and analysis of previously unpublished high-fidelity CFD simulation data of in silico rhinomanometry. While the two first parts of this paper summarize the current status and challenges in the application of computational tools in rhinology, the last part addresses the gross disagreement commonly observed when comparing in silico and in vivo rhinomanometry results. It is concluded that this discrepancy cannot readily be explained by CFD model deficiencies caused by poor choice of turbulence model, insufficient spatial or temporal resolution, or neglecting transient effects. Hence, alternative explanations such as nasal cavity compliance or drag effects due to nasal hair should be investigated.
Collapse
|
3
|
Bernstein JA, White AA, Han JK, Lang DM, Elkayam D, Baroody FM. Review of evidence supporting the use of nasal corticosteroid irrigation for chronic rhinosinusitis. Ann Allergy Asthma Immunol 2023; 130:46-57. [PMID: 36116748 DOI: 10.1016/j.anai.2022.09.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 09/06/2022] [Accepted: 09/07/2022] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To analyze published reports on the efficacy and safety of CSI in CRS and evaluate the clinical implications of current gaps in evidence. Corticosteroid irrigation (CSI) is commonly used for management of chronic rhinosinusitis (CRS) with nasal polyps; however, such use is not approved by the US Food and Drug Administration (FDA). DATA SOURCES Publications were obtained through PubMed searches through January 2022. STUDY SELECTION Searches were conducted using 2 terms: "chronic rhinosinusitis" or "nasal polyps" as the first term and "corticosteroid irrigation," "steroid nasal lavage," or "sinus rinse" as the second term. We reviewed relevant, peer-reviewed literature (19 original research [9 controlled, 10 uncontrolled trials], 7 reviews, and 1 meta-analysis) reporting safety and efficacy of CSI in patients with CRS. RESULTS Studies were difficult to compare because they used a variety of solution volumes (60 mL to 125 mL per nostril), corticosteroid agents (budesonide, betamethasone, mometasone, or fluticasone), corticosteroid doses, preparation protocols (by compounding pharmacy or by patient), and administration (frequency, time of day, body positioning). It is difficult to determine which parameters might substantially influence clinical effects because studies were generally small, showed marginal benefits, and rarely assessed safety. To date, no studies evaluating CSI have shown statistically significant differences in a type-I error-controlled primary end point over any comparator, possibly owing to small sample sizes. CONCLUSION Designing more robust clinical trials may help determine whether CSI is a valid treatment option. Until more evidence supporting CSI use exists, health care professionals should strongly consider choosing FDA-approved therapies for the treatment of CRS.
Collapse
Affiliation(s)
- Jonathan A Bernstein
- Division of Immunology-Allergy Section, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio.
| | - Andrew A White
- Division of Allergy, Asthma and Immunology, Scripps Clinic, La Jolla, California
| | - Joseph K Han
- Eastern Virginia Medical School, Norfolk, Virginia
| | - David M Lang
- Department of Allergy and Clinical Immunology, Respiratory Institute, Cleveland Clinic, Cleveland, Ohio
| | - David Elkayam
- Bellingham Asthma, Allergy and Immunology Clinic, Bellingham, Washington
| | - Fuad M Baroody
- Department of Surgery (Otolaryngology-Head and Neck Surgery) and Pediatrics, University of Chicago Medicine and the Comer Children's Hospital, Chicago, Illinois
| |
Collapse
|
4
|
Schmidt N, Behrbohm H, Goubergrits L, Hildebrandt T, Brüning J. Comparison of rhinomanometric and computational fluid dynamic assessment of nasal resistance with respect to measurement accuracy. Int J Comput Assist Radiol Surg 2022; 17:1519-1529. [PMID: 35821562 DOI: 10.1007/s11548-022-02699-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Accepted: 06/05/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Computational fluid dynamics (CFD)-based calculation of intranasal airflow became an important method in rhinologic research. Current evidence shows weak to moderate correlation as well as a systematic underprediction of nasal resistance by numerical simulations. In this study, we investigate whether these differences can be explained by measurement uncertainties caused by rhinomanometric devices and procedures. Furthermore, preliminary findings regarding the impact of tissue movements are reported. METHODS A retrospective sample of 17 patients, who reported impaired nasal breathing and for which rhinomanometric (RMM) measurements using two different devices as well as computed tomography scans were available, was investigated in this study. Three patients also exhibited a marked collapse of the nasal valve. Agreement between both rhinomanometric measurements as well as between rhinomanometry and CFD-based calculations was assessed using linear correlation and Bland-Altman analyses. These analyses were performed for the volume flow rates measured at trans-nasal pressure differences of 75 and 150 Pa during inspiration and expiration. RESULTS The correlation between volume flow rates measured using both RMM devices was good (R2 > 0.72 for all breathing states), and no relevant differences in measured flow rates was observed (21.6 ml/s and 14.8 ml/s for 75 and 150 Pa, respectively). In contrast, correlation between RMM and CFD was poor (R2 < 0.5) and CFD systematically overpredicted RMM-based flow rate measurements (231.8 ml/s and 328.3 ml/s). No differences between patients with and without nasal valve collapse nor between inspiration and expiration were observed. CONCLUSION Biases introduced during RMM measurements, by either the chosen device, the operator or other aspects as for example the nasal cycle, are not strong enough to explain the gross differences commonly reported between RMM- and CFD-based measurement of nasal resistance. Additionally, tissue movement during breathing is most likely also no sufficient explanation for these differences.
Collapse
Affiliation(s)
- Nora Schmidt
- Department of Otorhinolaryngology and Facial Plastic Surgery, Park-Klinik Weissensee, Schönstraße 80, 13086, Berlin, Germany.
| | - Hans Behrbohm
- Department of Otorhinolaryngology and Facial Plastic Surgery, Park-Klinik Weissensee, Schönstraße 80, 13086, Berlin, Germany
| | - Leonid Goubergrits
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Thomas Hildebrandt
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Jan Brüning
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
5
|
Wu D, Chang F, Hong J, Su B, Wei Y. A novel irrigation device with superior nasal irrigation efficiency to the classic rinse bottle. J Otolaryngol Head Neck Surg 2022; 51:19. [PMID: 35505412 PMCID: PMC9066877 DOI: 10.1186/s40463-022-00575-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 04/07/2022] [Indexed: 11/10/2022] Open
Abstract
Background The ability of saline irrigation to detach the mucous and the flow-limiting effect of the nasal valve has not been well explored. The objective of this study was to compare the removal efficiency of a novel irrigation device with an extended nozzle versus a classic rinse bottle. Methods Transparent casts of the unoperated sinonasal cavity were made by 3D printing. Yogurt was used to simulate mucous. The cast filled with 5 ml yogurt was fixed in six head positions and irrigated with 120 ml, 175 ml, and 240 ml dyed water through the novel device and the rinse bottle. The irrigation efficiency was the ratio of the weight of yogurt washed away divided by the total weight of yogurt. Results The irrigation stream of a long nozzle with a side opening was different from the irrigation stream of the outlet within the nasal vestibule. The novel devices presented with continuous water stream directly upwards to the anterior part of the olfactory cleft. Depending on different head positions, it was easy for the novel devices to achieve an irrigation efficiency of 100% when the cast was irrigated with 120 ml or 175 ml water. There was still a tiny amount of yogurt left in the olfactory cleft when the cast was irrigated with 240 ml water under each head position for the rinse bottle. The irrigation efficiency was volume-dependent, and the average irrigation efficiency of the rinse bottle at 240 ml only reached 69.1%. Conclusions The novel irrigation device presented with superior nasal irrigation efficiency to the classic rinse bottle. A continuous water stream directly upwards to the anterior part of the olfactory cleft combined with an extended nozzle overcoming the flow-limiting effect of the nasal valve promotes nasal irrigation efficiency. Graphical Abstract ![]()
Collapse
Affiliation(s)
- Dawei Wu
- Department of Otolaryngology-Head and Neck Surgery, Peking University Third Hospital, Beijing, People's Republic of China.
| | - Feifan Chang
- Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, People's Republic of China
| | - Junsheng Hong
- Department of Otolaryngology, Beijing Anzhen Hospital, Capital Medical University, Beijing, People's Republic of China
| | - Baihan Su
- Department of Otolaryngology, Beijing Anzhen Hospital, Capital Medical University, Beijing, People's Republic of China
| | - Yongxiang Wei
- Department of Otorhinolaryngology-Head and Neck Surgery, Capital Institute of Pediatrics, Beijing, People's Republic of China
| |
Collapse
|
6
|
MATARACI FURKAN, KARIMOV ULVI, OZDEMIR IBEDII, YILDIRIM DUZGUN, ALTINDAG AYTUG. CFD SIMULATIONS AND ANALYSES OF ASYMPTOMATIC AND SYMPTOMATIC NASAL AIRWAY OBSTRUCTIONS. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The numerical simulations of the flow in nasal airways were performed for two different clinical cases. The results comprised the distributions of scalars at five different sections and included contours of pressure, velocity magnitude, turbulent kinetic energy and vorticity magnitude. Simulations showed the air branching occurring at the inferior meatus is unaffected by the variations in the volumetric flow rate or the changes in the flow regime through the olfactory cleft. However, the contractions and the following rapid change in the cross-section of the nasopharynx preclude the upward penetration of the vacuum field set by the lungs during the inhalation process. As a result, considerably low velocities and significant cross-sectional nonuniformities are observed, which lead to the appearances of the secondary flow structures and strong unsteadiness. Increased interactions between the airflow and the walls of the nasal cavity resulted in an increase in the vorticity on the right middle meatus and upper inferior meatus. The vorticity was also very high in the nostrils, where the flow was not fully developed.
Collapse
Affiliation(s)
- FURKAN MATARACI
- Fluids Group, Faculty of Mechanical Engineering, Istanbul Technical University, Gumussuyu 34437, Istanbul, Turkey
| | - ULVI KARIMOV
- Fluids Group, Faculty of Mechanical Engineering, Istanbul Technical University, Gumussuyu 34437, Istanbul, Turkey
| | - I. BEDII OZDEMIR
- Fluids Group, Faculty of Mechanical Engineering, Istanbul Technical University, Gumussuyu 34437, Istanbul, Turkey
| | - DUZGUN YILDIRIM
- Department of Medical Imaging, Vocational School of Health Sciences, Acibadem University, Istanbul, Turkey
| | - AYTUG ALTINDAG
- Otorhinolaryngology Department, Medical Faculty, Biruni University, Istanbul, Turkey
| |
Collapse
|
7
|
Chen J, Martin AR, Finlay WH. Recent In Vitro and In Silico Advances in the Understanding of Intranasal Drug Delivery. Curr Pharm Des 2021; 27:1482-1497. [PMID: 33183191 DOI: 10.2174/1381612826666201112143230] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Revised: 10/02/2020] [Accepted: 10/06/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Many drugs are delivered intranasally for local or systemic effect, typically in the form of droplets or aerosols. Due to the high cost of in vivo studies, drug developers and researchers often turn to in vitro or in silico testing when first evaluating the behavior and properties of intranasal drug delivery devices and formulations. Recent advances in manufacturing and computer technologies have allowed for increasingly realistic and sophisticated in vitro and in silico reconstructions of the human nasal airways. OBJECTIVE The study aims to perform a summary of advances in the understanding of intranasal drug delivery based on recent in vitro and in silico studies. CONCLUSION The turbinates are a common target for local drug delivery applications, and while nasal sprays are able to reach this region, there is currently no broad consensus across the in vitro and in silico literature concerning optimal parameters for device design, formulation properties and patient technique which would maximize turbinate deposition. Nebulizers can more easily target the turbinates, but come with the disadvantage of significant lung deposition. Targeting of the olfactory region of the nasal cavity has been explored for the potential treatment of central nervous system conditions. Conventional intranasal devices, such as nasal sprays and nebulizers, deliver very little dose to the olfactory region. Recent progress in our understanding of intranasal delivery will be useful in the development of the next generation of intranasal drug delivery devices.
Collapse
Affiliation(s)
- John Chen
- Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, Canada
| | - Andrew R Martin
- Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, Canada
| | - Warren H Finlay
- Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, Canada
| |
Collapse
|
8
|
Oâ Neill G, Tolley NS. Modelling nasal airflow coefficients: an insight into the nature of airflow. Rhinology 2021; 59:66-74. [PMID: 32901617 DOI: 10.4193/rhin19.440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND There has been considerable discussion and conflicting views regarding the presence of laminar or turbulent flow within the nose. The aim of this study was to investigate how the modelling of variable flow coefficients can assist in the evalua- tion of the characteristics of flow in the resistive segments of the nose. METHODOLOGY A comparison was made between the flow coefficient for the nasal valve, obtained from a mathematical model, and resistive flow components such as a Venturi meter and orifice tube. Also, a variable loss coefficient was formulated for the whole (unilateral) nose which, by utilising the intersection of the laminar and turbulent asymptotes, provided an estimation for the critical Reynolds number (Rcrit). RESULTS The results show that the flow resistance of the nasal valve is considerably greater than that for both a Venturi meter and an orifice tube implying turbulent or turbulent-like flow for much of nasal inspiration. Regarding the loss coefficient for the whole (unilateral) nose, normal respiration flowrates are displaced well away from the laminar asymptote. The critical Reynolds number was estimated to be 450. CONCLUSIONS A novel method of determining the flow characteristics of the nose, particularly the critical Reynolds number, is presented. The analysis indicates a higher degree of turbulence than is assumed from a simple traditional calculation using a hy- draulic diameter and flow through straight tubes. There are implications for computational fluid dynamics (CFD) modelling where either the entire nasal airflow is assumed to be laminar or a low turbulence model implemented.
Collapse
Affiliation(s)
- G Oâ Neill
- Department of Otolaryngology, Head and Neck Surgery, St Mary's Hospital, London, United Kingdom
| | - N S Tolley
- Department of Otolaryngology, Head and Neck Surgery, St Mary's Hospital, London, United Kingdom
| |
Collapse
|
9
|
Role of nasal casts for in vitro evaluation of nasal drug delivery and quantitative evaluation of various nasal casts. Ther Deliv 2020; 11:485-495. [PMID: 32727298 DOI: 10.4155/tde-2020-0054] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: Nasal casts may characterize intranasal drug deposition. Methodology: The Koken cast, described as 'anatomically correct', and the Optinose cast, derived from MRI of a healthy male during velum closure, were dimensionally compared and assessed for deposition assessment suitability. Results: Smallest vertical cross-sectional areas (valve region) for Koken and Optinose right/left: 2.55/2.75 and 1.18/1.18 cm2, respectively, versus a 'normative' mean (range) of 0.85 cm2 (0.2-1.6 cm2). Intranasal volumes differed (computed tomography/water fill): Koken, 35.8/38.6 cm3 and Optinose, 24.1/25.0 cm3, versus a 'normative' mean (range) of 26.4 cm3 (20.9-31.1 cm3). Conclusion: Koken cast dimensions are larger than the normal range and the Optinose cast. The validity of casts for regulatory drug deposition studies is suspect.
Collapse
|
10
|
Abstract
The objective of this study was to investigate the effects of nasal valve area, valve stiffness, and turbinate region cross-sectional area on airflow rate, nasal resistance, flow limitation, and inspiratory "hysteresis" by the use of a mathematical model of nasal airflow. The model of O'Neill and Tolley (Clin Otolaryngol Allied Sci 13: 273-277, 1988) describing the effects of valve area and stiffness on the nasal pressure-flow relationship was improved by the incorporation of additional terms involving 1) airflow through the turbinate region, 2) the dependence of the flow coefficients for the valve and turbinate region on the Reynolds number, and 3) effects of unsteady flow. The model was found to provide a good fit for normal values for nasal resistance and for pressure-flow curves reported in the literature for both congested and decongested states. Also, by showing the relative contribution of the nasal valve and turbinate region to nasal resistance, the model sheds light in explaining the generally poor correlation between nasal resistance measurements and the results from acoustic rhinometry. Furthermore, by proposing different flow conditions for the acceleration and deceleration phases of inspiration, the model produces an inspiratory loop (commonly referred to as hysteresis) consistent with those reported in the literature. With simulation of nasal flaring, the magnitude of the loop, the nasal resistance, and flow limitation all show change similar to that observed in the experimental results.NEW & NOTEWORTHY The present model provides considerable insight into some difficult conundrums in both clinical and technical aspects of nasal airflow. Also, the description of nasal airflow mechanics based on the Hagen-Poiseuille equation and Reynolds laminar-turbulent transition in long straight tubes, which has figured prominently in medical textbooks and journal articles for many years, is shown to be seriously in error at a fundamental level.
Collapse
Affiliation(s)
- Graham O'Neill
- Department of Otolaryngology-Head and Neck Surgery, St Mary's Hospital, London, United Kingdom
| | - Neil Samuel Tolley
- Department of Otolaryngology-Head and Neck Surgery, St Mary's Hospital, London, United Kingdom
| |
Collapse
|
11
|
Osman J, Großmann F, Brosien K, Kertzscher U, Goubergrits L, Hildebrandt T. Assessment of nasal resistance using computational fluid dynamics. CURRENT DIRECTIONS IN BIOMEDICAL ENGINEERING 2016. [DOI: 10.1515/cdbme-2016-0136] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
AbstractAnterior rhinomanometry is the current gold standard for the objective assessment of nasal breathing by determining the nasal resistance. However, computational fluid dynamics would allow spatially and temporally well- resolved investigation of additional flow parameters. In this study, measured values of nasal resistance are compared with measured values. An unclear discrepancy between the two methods was found, suggesting further investigation.
Collapse
Affiliation(s)
- Jan Osman
- 1Charité – Universitätsmedizin Berlin, Biofluid Mechanics Laboratory, Augustenburger Berlin, Germany
| | - Friederike Großmann
- 1Charité – Universitätsmedizin Berlin, Biofluid Mechanics Laboratory, Augustenburger Berlin, Germany
| | - Kay Brosien
- 1Charité – Universitätsmedizin Berlin, Biofluid Mechanics Laboratory, Augustenburger Berlin, Germany
| | - Ulrich Kertzscher
- 1Charité – Universitätsmedizin Berlin, Biofluid Mechanics Laboratory, Augustenburger Berlin, Germany
| | - Leonid Goubergrits
- 1Charité – Universitätsmedizin Berlin, Biofluid Mechanics Laboratory, Augustenburger Berlin, Germany
| | | |
Collapse
|
12
|
Bates AJ, Doorly DJ, Cetto R, Calmet H, Gambaruto AM, Tolley NS, Houzeaux G, Schroter RC. Dynamics of airflow in a short inhalation. J R Soc Interface 2015; 12:20140880. [PMID: 25551147 PMCID: PMC4277078 DOI: 10.1098/rsif.2014.0880] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
During a rapid inhalation, such as a sniff, the flow in the airways accelerates and decays quickly. The consequences for flow development and convective transport of an inhaled gas were investigated in a subject geometry extending from the nose to the bronchi. The progress of flow transition and the advance of an inhaled non-absorbed gas were determined using highly resolved simulations of a sniff 0.5 s long, 1 l s⁻¹ peak flow, 364 ml inhaled volume. In the nose, the distribution of airflow evolved through three phases: (i) an initial transient of about 50 ms, roughly the filling time for a nasal volume, (ii) quasi-equilibrium over the majority of the inhalation, and (iii) a terminating phase. Flow transition commenced in the supraglottic region within 20 ms, resulting in large-amplitude fluctuations persisting throughout the inhalation; in the nose, fluctuations that arose nearer peak flow were of much reduced intensity and diminished in the flow decay phase. Measures of gas concentration showed non-uniform build-up and wash-out of the inhaled gas in the nose. At the carina, the form of the temporal concentration profile reflected both shear dispersion and airway filling defects owing to recirculation regions.
Collapse
Affiliation(s)
- A. J. Bates
- Department of Aeronautics, Imperial College London, London SW7 2AZ, UK
- e-mail:
| | - D. J. Doorly
- Department of Aeronautics, Imperial College London, London SW7 2AZ, UK
| | - R. Cetto
- Department of Aeronautics, Imperial College London, London SW7 2AZ, UK
- Department of Otolaryngology, St Mary's Hospital, Imperial College Healthcare Trust, London W2 1NY, UK
| | - H. Calmet
- Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC-CNS), Barcelona 08034, Spain
| | - A. M. Gambaruto
- Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC-CNS), Barcelona 08034, Spain
| | - N. S. Tolley
- Department of Otolaryngology, St Mary's Hospital, Imperial College Healthcare Trust, London W2 1NY, UK
| | - G. Houzeaux
- Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC-CNS), Barcelona 08034, Spain
| | - R. C. Schroter
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| |
Collapse
|
13
|
White DE, Bartley J, Nates RJ. Model demonstrates functional purpose of the nasal cycle. Biomed Eng Online 2015; 14:38. [PMID: 25907572 PMCID: PMC4416271 DOI: 10.1186/s12938-015-0034-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 04/08/2015] [Indexed: 11/18/2022] Open
Abstract
Background Despite the occurrence of the nasal cycle being well documented, the functional purpose of this phenomenon is not well understood. This investigation seeks to better understand the physiological objective of the nasal cycle in terms of airway health through the use of a computational nasal air-conditioning model. Method A new state-variable heat and water mass transfer model is developed to predict airway surface liquid (ASL) hydration status within each nasal airway. Nasal geometry, based on in-vivo magnetic resonance imaging (MRI) data is used to apportion inter-nasal air flow. Results The results demonstrate that the airway conducting the majority of the airflow also experiences a degree of ASL dehydration, as a consequence of undertaking the bulk of the heat and water mass transfer duties. In contrast, the reduced air conditioning demand within the other airway allows its ASL layer to remain sufficiently hydrated so as to support continuous mucociliary clearance. Conclusions It is quantitatively demonstrated in this work how the nasal cycle enables the upper airway to accommodate the contrasting roles of air conditioning and the removal of entrapped contaminants through fluctuation in airflow partitioning between each airway.
Collapse
Affiliation(s)
- David E White
- School of Engineering, Auckland University of Technology, Auckland, New Zealand.
| | - Jim Bartley
- Department of Surgery, University of Auckland, Auckland, New Zealand.
| | - Roy J Nates
- School of Engineering, Auckland University of Technology, Auckland, New Zealand.
| |
Collapse
|
14
|
Louis B, Papon JF, Croce C, Caillibotte G, Sbirlea-Apiou G, Coste A, Fodil R, Isabey D. Frictional resistance sheds light on the multicomponent nature of nasal obstruction: a combined in vivo and computational fluid dynamics study. Respir Physiol Neurobiol 2013; 188:133-42. [PMID: 23727227 DOI: 10.1016/j.resp.2013.05.024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2012] [Revised: 05/19/2013] [Accepted: 05/22/2013] [Indexed: 10/26/2022]
Abstract
Exploring nasal flow contributes to better understanding of pathophysiological functions of nasal cavities. We combined the rhinomanometry measurements of 11 patients and computational fluid dynamics (CFD) simulations in 3 nasal airway models to dissect the complex mechanisms that determine nasal flow obstruction: spatial complexity and pressure-dependent deformability of nasal airways. We quantified spatial complexity by calculating longitudinal variations of hydraulic diameter, perimeter and area of nasal cavities, and their impact on flow characteristics by examining the longitudinal variations of the kinetic energy coefficient and the kinetic to potential energy ratio. Airway distensibility variably affected in vivo pressure-flow relationships through the appearance of flow-limitation patterns characterized by maximum flow and/or flow plateau. We quantified deformability and spatial complexity effects on nasal airway resistance by normalizing all data with averaged reference parameters. The results show that discrepancies in nasal flow resistances reflect airway deformability and geometrical complexity, and thereby constitute a framework to better characterize nasal obstruction.
Collapse
Affiliation(s)
- Bruno Louis
- Inserm, U955, Equipe 13, Cell and Respiratory Mechanics Department, 8, rue du Général Sarrail, F-94010 Créteil Cedex, France.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Djupesland PG. Nasal drug delivery devices: characteristics and performance in a clinical perspective-a review. Drug Deliv Transl Res 2013; 3:42-62. [PMID: 23316447 PMCID: PMC3539067 DOI: 10.1007/s13346-012-0108-9] [Citation(s) in RCA: 322] [Impact Index Per Article: 29.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Nasal delivery is the logical choice for topical treatment of local diseases in the nose and paranasal sinuses such as allergic and non-allergic rhinitis and sinusitis. The nose is also considered an attractive route for needle-free vaccination and for systemic drug delivery, especially when rapid absorption and effect are desired. In addition, nasal delivery may help address issues related to poor bioavailability, slow absorption, drug degradation, and adverse events in the gastrointestinal tract and avoids the first-pass metabolism in the liver. However, when considering nasal delivery devices and mechanisms, it is important to keep in mind that the prime purpose of the nasal airway is to protect the delicate lungs from hazardous exposures, not to serve as a delivery route for drugs and vaccines. The narrow nasal valve and the complex convoluted nasal geometry with its dynamic cyclic physiological changes provide efficient filtration and conditioning of the inspired air, enhance olfaction, and optimize gas exchange and fluid retention during exhalation. However, the potential hurdles these functional features impose on efficient nasal drug delivery are often ignored. With this background, the advantages and limitations of existing and emerging nasal delivery devices and dispersion technologies are reviewed with focus on their clinical performance. The role and limitations of the in vitro testing in the FDA guidance for nasal spray pumps and pressurized aerosols (pressurized metered-dose inhalers) with local action are discussed. Moreover, the predictive value and clinical utility of nasal cast studies and computer simulations of nasal airflow and deposition with computer fluid dynamics software are briefly discussed. New and emerging delivery technologies and devices with emphasis on Bi-Directional™ delivery, a novel concept for nasal delivery that can be adapted to a variety of dispersion technologies, are described in more depth.
Collapse
|
16
|
Xi J, Kim J, Si XA, Zhou Y. Hygroscopic aerosol deposition in the human upper respiratory tract under various thermo-humidity conditions. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2013; 48:1790-805. [PMID: 24007434 DOI: 10.1080/10934529.2013.823333] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The deposition of hygroscopic aerosols is highly complex in nature, which results from a cumulative effect of dynamic particle growth and the real-time size-specific deposition mechanisms. The objective of this study is to evaluate hygroscopic effects on the particle growth, transport, and deposition of nasally inhaled aerosols across a range of 0.2-2.5 μm in an adult image-based nose-throat model. Temperature and relative humidity fields were simulated using the LRN k-ω turbulence model and species transport model under a spectrum of thermo-humidity conditions. Particle growth and transport were simulated using a well validated Lagrangian tracking model coupled with a user-defined hygroscopic growth module. Results of this study indicate that the saturation level and initial particle size are the two major factors that determine the particle growth rate (d/d0), while the effect of inhalation flow rate is found to be not significant. An empirical correlation of condensation growth of nasally inhaled hygroscopic aerosols in adults has been developed based on a variety of thermo-humidity inhalation conditions. Significant elevated nasal depositions of hygroscopic aerosols could be induced by condensation growth for both sub-micrometer and small micrometer particulates. In particular, the deposition of initially 2.5 μm hygroscopic aerosols was observed to be 5-8 times that of inert particles under warm to hot saturated conditions. Results of this study have important implications in exposure assessment in hot humid environments, where much higher risks may be expected compared to normal conditions.
Collapse
Affiliation(s)
- Jinxiang Xi
- Department of Mechanical and Biomedical Engineering, Central Michigan University, Mount Pleasant, Michigan 48858, USA.
| | | | | | | |
Collapse
|
17
|
Kim JW, Xi J, Si XA. Dynamic growth and deposition of hygroscopic aerosols in the nasal airway of a 5-year-old child. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2013; 29:17-39. [PMID: 23293067 DOI: 10.1002/cnm.2490] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2012] [Revised: 04/05/2012] [Accepted: 04/14/2012] [Indexed: 05/04/2023]
Abstract
Hygroscopic growth within the human respiratory tract can be significant, which may notably alter the behavior and fate of the inhaled aerosols. The objective of this study is to evaluate the hygroscopic effects upon the transport and deposition of nasally inhaled fine-regime aerosols in children. A physiologically realistic nasal-laryngeal airway model was developed based on magnetic resonance imaging of a 5-year-old boy. Temperature and relative humidity field were simulated using the low Reynolds number k - ε turbulence model and chemical specie transport model under a spectrum of four thermo-humidity conditions. Particle growth and transport were simulated using a well validated Lagrangian tracking model coupled with a user-defined hygroscopic growth module. The subsequent aerosol depositions for the four inhalation scenarios were evaluated on a multiscale basis such as total, subregional, and cellular-level depositions. Results of this study show that a supersaturated humid environment is possible in the nasal turbinate region and can lead to significant condensation growth (d / d(0) > 10) of nasally inhaled aerosols. Depositions in the nasal airway can also be greatly enhanced by condensation growth with appropriate inhalation temperature and humidity. For subsaturated and mild inhalation conditions, the hygroscopic effects were found to be nonsignificant for total depositions, while exerting a large impact upon localized depositions.
Collapse
Affiliation(s)
- Jong Won Kim
- Department of Systems Engineering, University of Arkansas, Little Rock, AR, U.S.A
| | | | | |
Collapse
|
18
|
Si X, Xi J, Kim J. Effect of Laryngopharyngeal Anatomy on Expiratory Airflow and Submicrometer Particle Deposition in Human Extrathoracic Airways. ACTA ACUST UNITED AC 2013. [DOI: 10.4236/ojfd.2013.34036] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
19
|
Breathing Resistance and Ultrafine Particle Deposition in Nasal–Laryngeal Airways of a Newborn, an Infant, a Child, and an Adult. Ann Biomed Eng 2012; 40:2579-95. [DOI: 10.1007/s10439-012-0603-7] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2012] [Accepted: 05/22/2012] [Indexed: 12/31/2022]
|
20
|
Djupesland PG, Skretting A. Nasal deposition and clearance in man: comparison of a bidirectional powder device and a traditional liquid spray pump. J Aerosol Med Pulm Drug Deliv 2012; 25:280-9. [PMID: 22251061 DOI: 10.1089/jamp.2011.0924] [Citation(s) in RCA: 99] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Delivery of powder formulations to the nose is an attractive alternative for many drugs and vaccines. This study compared the regional nasal deposition and clearance patterns of lactose powder delivered by the OptiNose powder device (Opt-Powder; OptiNose US Inc., Yardley, PA, USA) to that of liquid aerosol administered via a traditional hand-actuated liquid spray pump (Rexam SP270, Rexam Pharma, France). METHODS The study was an open-label, crossover design in seven healthy subjects (five females, two males). The regional nasal deposition and clearance patterns of the Opt-Powder device were compared to a traditional liquid spray pump by dynamic gamma camera imaging after administration of either (99m)Tc-labeled lactose powder or liquid (99m)Tc- diethelyne triamine pentaacetic acid-aerosol. The gamma camera images were scaled and aligned with sagittal magnetic resonance images to identify nasal regions. Possible deposition of radiolabeled material in the lungs following both methods of delivery was also evaluated. RESULTS Both powder and spray were distributed to all of the nasal regions. The Opt-Powder device, however, achieved significantly larger initial deposition in the upper and middle posterior regions of the nose than spray (upper posterior region; Opt-Powder 18.3% ± 11.5 vs. Spray 2.4% ± 1.8, p<0.02; sum of upper and middle posterior regions; Opt-Powder 53.5% ± 18.5 vs. Spray 15.7% ± 13.8, p<0.02). The summed initial deposition to the lower anterior and posterior regions for spray was three times higher compared to Opt-Powder (Opt-Powder 17.4% ± 24.5 vs. Spray 59.4% ± 18.2, p<0.04). OptiNose powder delivery resulted in more rapid overall nasal clearance. No lung deposition was observed. CONCLUSIONS The initial deposition following powder delivery was significantly larger in the ciliated mucosa of the upper and posterior nasal regions, whereas less was deposited in the lower regions. Overall nasal clearance of powder was slower initially, but due to retention in anterior nonciliated regions the overall nasal clearance after spray was slower.
Collapse
|
21
|
Nino G, Baloglu O, Gutierrez MJ, Schwartz M. Scientific rationale for the use of alpha-adrenergic agonists and glucocorticoids in the therapy of pediatric stridor. Int J Otolaryngol 2011; 2011:575018. [PMID: 22220172 PMCID: PMC3246738 DOI: 10.1155/2011/575018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2011] [Accepted: 08/26/2011] [Indexed: 11/18/2022] Open
Abstract
Purpose. The most common pharmacological therapies used in the treatment of stridor in children are glucocorticosteroids (GC) and alpha-adrenergic (αAR) agonists. Despite the long-standing reported efficacy of these medications, there is a paucity of data relating to their actual mechanisms of action in the upper airway. Summary. There is compelling scientific evidence supporting the use of αAR-agonists and GCs in pediatric stridor. αAR signaling and GCs regulate the vasomotor tone in the upper airway mucosa. The latter translates into better airflow dynamics, as delineated by human and nonhuman upper airway physiological models. In turn, clinical trials have demonstrated that GCs and the nonselective αAR agonist, epinephrine, improve respiratory distress scores and reduce the need for further medical care in children with stridor. Future research is needed to investigate the role of selective αAR agonists and the potential synergism of GCs and αAR-signaling in the treatment of upper airway obstruction and stridor.
Collapse
Affiliation(s)
- Gustavo Nino
- Division of Pediatric Pulmonary Medicine, Penn State Hershey Children's Hospital, Pennsylvania State University College of Medicine, Hershey, PA 17033, USA
- Penn State Sleep Research and Treatment Center, Pennsylvania State University College of Medicine, 500 University Drive, Hershey, PA 17033, USA
| | - Orkun Baloglu
- Division of Pediatric Pulmonary Medicine, Penn State Hershey Children's Hospital, Pennsylvania State University College of Medicine, Hershey, PA 17033, USA
| | - Maria J. Gutierrez
- Division of Allergy and Immunology, Pennsylvania State University College of Medicine, Hershey, PA 17033, USA
| | - Michael Schwartz
- Division of Pediatric Pulmonary Medicine, Penn State Hershey Children's Hospital, Pennsylvania State University College of Medicine, Hershey, PA 17033, USA
| |
Collapse
|
22
|
Groß TF, Peters F. A fluid mechanical interpretation of hysteresis in rhinomanometry. ISRN OTOLARYNGOLOGY 2011; 2011:126520. [PMID: 23724249 PMCID: PMC3658487 DOI: 10.5402/2011/126520] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2011] [Accepted: 07/26/2011] [Indexed: 11/23/2022]
Abstract
A hysteresis effect in the pressure/flow rate relationship of nasal breathing has frequently been observed in clinical tests and in lab investigations. Explanations that have been given in the literature are missing a fluid mechanic storage effect coming into play in reciprocating flows. This effect depends primarily on the way the rhinomanometric measurements are set up and not so much on the nose flow itself. This is to be shown by calculations and experiments. The experiments are carried out with orifices because they can represent nose flow and are often implemented in rhinomanometric equipment as flow gauges. To mimic reality also a 1 : 1 nose model is used. It is shown where the hysteresis comes from and what the key parameters for its prediction are. With these results hysteresis in nasal breathing appears in a new light.
Collapse
Affiliation(s)
- T F Groß
- Lehrstuhl für Strömungsmechanik, Ruhr-Universität Bochum, 44780 Bochum, Germany
| | | |
Collapse
|
23
|
Leboulanger N, Louis B, Fodil R, Boelle PY, Clément A, Garabedian EN, Fauroux B. Analysis of the pharynx and the trachea by the acoustic reflection method in children: A pilot study. Respir Physiol Neurobiol 2011; 175:228-33. [DOI: 10.1016/j.resp.2010.11.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2010] [Revised: 11/16/2010] [Accepted: 11/18/2010] [Indexed: 11/17/2022]
|
24
|
Doorly DJ, Taylor DJ, Schroter RC. Mechanics of airflow in the human nasal airways. Respir Physiol Neurobiol 2008; 163:100-10. [PMID: 18786659 DOI: 10.1016/j.resp.2008.07.027] [Citation(s) in RCA: 136] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2008] [Revised: 07/30/2008] [Accepted: 07/30/2008] [Indexed: 11/16/2022]
Abstract
The mechanics of airflow in the human nasal airways is reviewed, drawing on the findings of experimental and computational model studies. Modelling inevitably requires simplifications and assumptions, particularly given the complexity of the nasal airways. The processes entailed in modelling the nasal airways (from defining the model, to its production and, finally, validating the results) is critically examined, both for physical models and for computational simulations. Uncertainty still surrounds the appropriateness of the various assumptions made in modelling, particularly with regard to the nature of flow. New results are presented in which high-speed particle image velocimetry (PIV) and direct numerical simulation are applied to investigate the development of flow instability in the nasal cavity. These illustrate some of the improved capabilities afforded by technological developments for future model studies. The need for further improvements in characterising airway geometry and flow together with promising new methods are briefly discussed.
Collapse
Affiliation(s)
- D J Doorly
- Department of Aeronautics, Imperial College London, Exhibition Road, London SW7 2AZ, UK.
| | | | | |
Collapse
|
25
|
Nathan RA, Eccles R, Howarth PH, Steinsvåg SK, Togias A. Objective monitoring of nasal patency and nasal physiology in rhinitis. J Allergy Clin Immunol 2007; 115:S442-59. [PMID: 15746882 PMCID: PMC7112320 DOI: 10.1016/j.jaci.2004.12.015] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/30/2022]
Abstract
Nasal obstruction can be monitored objectively by measurement of nasal airflow, as evaluated by nasal peak flow, or as airways resistance/conductance as evaluated by rhinomanometry. Peak flow can be measured during inspiration or expiration. Of these measurements, nasal inspiratory peak flow is the best validated technique for home monitoring in clinical trials. The equipment is portable, relatively inexpensive, and simple to use. One disadvantage, however, is that nasal inspiratory peak flow is influenced by lower airway as well as upper airway function. Rhinomanometry is a more sensitive technique that is specific for nasal measurements. The equipment, however, requires an operator, is more expensive, and is not portable. Thus, it is applicable only for clinic visit measures in clinical trials. Measurements require patient cooperation and coordination, and not all can achieve repeatable results. Thus, this objective measure is best suited to laboratory challenge studies involving smaller numbers of selected volunteers. A nonphysiological measure of nasal patency is acoustic rhinometry. This sonic echo technique measures internal nasal luminal volume and the minimum cross-sectional area. The derivation of these measures from the reflected sound waves requires complex mathematical transformation and makes several theoretical assumptions. Despite this, however, such measures correlate well with the nasal physiological measures, and the nasal volume measures have been shown to relate well to results obtained by imaging techniques such as computed tomography scanning or magnetic resonance imaging. Like rhinomanometry, acoustic rhinometry is not suitable for home monitoring and can be applied only to clinic visit measures or for laboratory nasal challenge monitoring. It has advantages in being easy to use, in requiring little patient cooperation, and in providing repeatable results. In addition to nasal obstruction, allergic rhinitis is recognized to be associated with impaired mucociliary clearance and altered nasal responsiveness. Measures exist for the monitoring of these aspects of nasal dysfunction. Although measures of mucociliary clearance are simple to perform, they have a poor record of reproducibility. Their incorporation into clinical trials is thus questionable, although positive outcomes from therapeutic intervention have been reported. Measures of nasal responsiveness are at present largely confined to research studies investigating disease mechanisms in allergic and nonallergic rhinitis. The techniques are insufficiently standardized to be applied to multicenter clinical trials but could be used in limited-center studies to gain insight into the regulatory effects of different therapeutic modalities.
Collapse
MESH Headings
- Humans
- Monitoring, Immunologic/methods
- Nasal Mucosa/immunology
- Nasal Mucosa/pathology
- Nasal Obstruction/immunology
- Nasal Obstruction/pathology
- Rhinitis, Allergic, Perennial/immunology
- Rhinitis, Allergic, Perennial/pathology
- Rhinitis, Allergic, Seasonal/immunology
- Rhinitis, Allergic, Seasonal/pathology
- Rhinomanometry
- Rhinometry, Acoustic
Collapse
Affiliation(s)
- Robert A Nathan
- Asthma and Allergy Associates, 2709 North Tejon, Colorado Springs, CO 80907, USA.
| | | | | | | | | |
Collapse
|
26
|
Shi H, Kleinstreuer C, Zhang Z. Laminar airflow and nanoparticle or vapor deposition in a human nasal cavity model. J Biomech Eng 2006; 128:697-706. [PMID: 16995756 DOI: 10.1115/1.2244574] [Citation(s) in RCA: 110] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The transport and deposition of nanoparticles, i.e., dp = 1-2 nm, or equivalent vapors, in the human nasal cavities is of interest to engineers, scientists, air-pollution regulators, and healthcare officials alike. Tiny ultrafine particles, i.e., dp < or = 5 nm, are of special interest because they are most rapidly absorbed and hence have an elevated toxic or therapeutic impact when compared to larger particles. Assuming transient laminar 3-D incompressible flow in a representative human nasal cavity, the cyclic airflow pattern as well as local and overall nanoparticle depositions were computationally simulated and analyzed. The focus was on transient effects during inhalation/exhalation as compared to the steady-state assumption typically invoked. Then, an equation for a matching steady-state inhalation flow rate was developed that generates the same deposition results as cyclic inhalation. Of special interest is the olfactory region where the narrow channel surfaces receive only about one-half of a percent of the inhaled nanoparticles because the airflow bypasses these recesses located in the superior-most portions in the geometrically complex nasal cavities.
Collapse
Affiliation(s)
- H Shi
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
| | | | | |
Collapse
|
27
|
Croce C, Fodil R, Durand M, Sbirlea-Apiou G, Caillibotte G, Papon JF, Blondeau JR, Coste A, Isabey D, Louis B. In vitro experiments and numerical simulations of airflow in realistic nasal airway geometry. Ann Biomed Eng 2006; 34:997-1007. [PMID: 16783655 DOI: 10.1007/s10439-006-9094-8] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2005] [Accepted: 02/21/2006] [Indexed: 11/30/2022]
Abstract
Pressure-flow relationships measured in human plastinated specimen of both nasal cavities and maxillary sinuses were compared to those obtained by numerical airflow simulations in a numerical three-dimensional reconstruction issued from CT scans of the plastinated specimen. For experiments, flow rates up to 1,500 ml/s were tested using three different gases: HeO(2), Air, and SF(6). Numerical inspiratory airflow simulations were performed for flow rates up to 353 ml/s in both the nostrils using a finite-volume-based method under steady-state conditions with CFD software using a laminar model. The good agreement between measured and numerically computed total pressure drops observed up to a flow rate of 250 ml/s is an important step to validate the ability of CFD software to describe flow in a physiologically realistic binasal model. The major total pressure drop was localized in the nasal valve region. Airflow was found to be predominant in the inferior median part of nasal cavities. Two main vortices were observed downstream from the nasal valve and toward the olfactory region. In the future, CFD software will be a useful tool for the clinician by providing a better understanding of the complexity of three-dimensional breathing flow in the nasal cavities allowing more appropriate management of the patient's symptoms.
Collapse
Affiliation(s)
- Céline Croce
- Fonctions Cellulaires et Moléculaires de l'Appareil Respiratoire et des Vaisseaux, Equipe Biomécanique Cellulaire et Respiratoire, INSERM UMR 651, Créteil, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Papon JF, Brugel-Ribere L, Fodil R, Croce C, Larger C, Rugina M, Coste A, Isabey D, Zerah-Lancner F, Louis B. Nasal wall compliance in vasomotor rhinitis. J Appl Physiol (1985) 2005; 100:107-11. [PMID: 16141379 DOI: 10.1152/japplphysiol.00575.2005] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Nasal compliance is a measure related to the blood volume in the nasal mucosa. The objective of this study was to better understand the vascular response in vasomotor rhinitis by measuring nasal cross-sectional area and nasal compliance before and after mucosal decongestion in 10 patients with vasomotor rhinitis compared with 10 healthy subjects. Nasal compliance was inferred by measuring nasal area by acoustic rhinometry at pressures ranging from atmospheric pressure to a negative pressure of -10 cmH2O. Mucosal decongestion was obtained with one puff per nostril of 0.05% oxymetazoline. At atmospheric pressure, nasal cross-sectional areas were similar in the vasomotor rhinitis group and the healthy subject group. Mucosal decongestion did not induce any decrease of nasal compliance in patients with vasomotor rhinitis in contrast with healthy subjects. Our results support the hypothesis, already proposed, of an autonomic dysfunction based on a paradoxical response of the nasal mucosa in vasomotor rhinitis. Moreover, the clearly different behavior between healthy subjects and vasomotor rhinitis subjects suggests that nasal compliance measurement may therefore represent a potential line of research to develop a diagnostic tool for vasomotor rhinitis, which remains a diagnosis of exclusion.
Collapse
Affiliation(s)
- Jean-François Papon
- Physiopathologie et Thérapeutique Respiratoires INSERM UMR 651, Créteil, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Fodil R, Croce C, Louis B, Coste A, Blondeau J, Isabey D, Perchet D, Fetita C, Preteux F, Grenier P, Vial L, Caillibotte G, Till M, Maday Y, Thiriet M, de Rochefort L, Maître X, Bittoun J, Durand E, Sbirlea-Apiou G. Simulateur morphofonctionnel des voies aériennes supérieures et proximales. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/j.rbmret.2004.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|