1
|
López-Ramos D, Eustaquio-Martín A, López-Bascuas LE, Lopez-Poveda EA. Effect of stimulus duration on estimates of human cochlear tuning. Hear Res 2024; 451:109080. [PMID: 39004016 DOI: 10.1016/j.heares.2024.109080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 06/21/2024] [Accepted: 07/10/2024] [Indexed: 07/16/2024]
Abstract
Auditory masking methods originally employed to assess behavioral frequency selectivity have evolved over the years to infer cochlear tuning. Behavioral forward masking thresholds for spectrally notched noise maskers and a fixed, low-level probe tone provide accurate estimates of cochlear tuning. Here, we use this method to investigate the effect of stimulus duration on human cochlear tuning at 500 Hz and 4 kHz. Probes were 20-ms sinusoids at 10 dB sensation level. Maskers were noises with a spectral notch symmetrically and asymmetrically placed around the probe frequency. For seven participants with normal hearing, masker levels at masking threshold were measured in forward masking for various notch widths and for masker durations of 30 and 400 ms. Measurements were fitted assuming rounded exponential filter shapes and the power spectrum model of masking, and equivalent rectangular bandwidths (ERBs) were inferred from the fits. At 4 kHz, masker thresholds were higher for the shorter maskers but ERBs were not significantly different for the two masker durations (ERB30ms=294 Hz vs. ERB400ms=277 Hz). At 500 Hz, by contrast, notched-noise curves were shallower for the 30-ms than the 400-ms masker, and ERBs were significantly broader for the shorter masker (ERB30ms=126 Hz vs. ERB400ms=55 Hz). We discuss possible factors that may underlay the duration effect at low frequencies and argue that it may not be possible to fully control for those factors. We conclude that tuning estimates are not affected by maker duration at high frequencies but should be measured and interpreted with caution at low frequencies.
Collapse
Affiliation(s)
- David López-Ramos
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, 37007 Salamanca, Spain
| | - Almudena Eustaquio-Martín
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, 37007 Salamanca, Spain
| | - Luis E López-Bascuas
- Departamento de Psicología Experimental, Procesos Cognitivos y Logopedia, Universidad Complutense de Madrid, 28223 Pozuelo de Alarcón, Madrid, Spain
| | - Enrique A Lopez-Poveda
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, 37007 Salamanca, Spain; Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, 37007 Salamanca, Spain; Departamento de Cirugía, Facultad de Medicina, Universidad de Salamanca, 37007 Salamanca, Spain.
| |
Collapse
|
2
|
Goodman SS, Haysley S, Jennings SG. Human Olivocochlear Effects: A Statistical Detection Approach Applied to the Cochlear Microphonic Evoked by Swept Tones. J Assoc Res Otolaryngol 2024:10.1007/s10162-024-00956-z. [PMID: 38954166 DOI: 10.1007/s10162-024-00956-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 06/12/2024] [Indexed: 07/04/2024] Open
Abstract
The human medial olivocochlear (MOC) reflex was assessed by observing the effects of contralateral acoustic stimulation (CAS) on the cochlear microphonic (CM) across a range of probe frequencies. A frequency-swept probe tone (125-4757 Hz, 90 dB SPL) was presented in two directions (up sweep and down sweep) to normal-hearing young adults. This study assessed MOC effects on the CM in individual participants using a statistical approach that calculated minimum detectable changes in magnitude and phase based on CM signal-to-noise ratio (SNR). Significant increases in CM magnitude, typically 1-2 dB in size, were observed for most participants from 354 to 1414 Hz, where the size and consistency of these effects depended on participant, probe frequency, sweep direction, and SNR. CAS-related phase lags were also observed, consistent with CM-based MOC studies in laboratory animals. Observed effects on CM magnitude and phase were in the opposite directions of reported effects on otoacoustic emissions (OAEs). OAEs are sensitive to changes in the motility of outer hair cells located near the peak region of the traveling wave, while the effects of CAS on the CM likely originate from MOC-related changes in the conductance of outer hair cells located in the basal tail of the traveling wave. Thus, MOC effects on the CM are complementary to those observed for OAEs.
Collapse
Affiliation(s)
- Shawn S Goodman
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, IA, USA
| | - Sarah Haysley
- Department of Communication Sciences and Disorders, University of Utah, Salt Lake City, UT, USA
| | - Skyler G Jennings
- Department of Communication Sciences and Disorders, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
3
|
Jedrzejczak WW, Pilka E, Pastucha M, Skarzynski H, Kochanek K. Magnitude of medial olivocochlear reflex assayed by tone-burst-evoked otoacoustic emissions: reliability and comparison with click-evoked emissions. Int J Audiol 2024; 63:293-299. [PMID: 37129585 DOI: 10.1080/14992027.2023.2207116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 04/20/2023] [Indexed: 05/03/2023]
Abstract
OBJECTIVE The purpose of this pilot study was to evaluate the magnitude of the medial olivocochlear reflex (MOCR) estimated by the reduction in tone-burst evoked otoacoustic emissions (TBOAEs) measured at three levels and at three frequencies in response to fixed contralateral white noise. Results were compared with commonly used click-evoked otoacoustic emissions (CEOAEs). DESIGN TBOAEs and CEOAEs, with and without contralateral 60 dB SPL white noise, were measured in response to stimulation at 55, 65, and 75 dB peSPL. In each subject, the set of measurements was performed twice. Of particular interest were the MOCR and its repeatability. STUDY SAMPLE 15 normally hearing persons (13 women, average age 32.3 years, SD = 8.1). RESULTS For both CEOAE and TBOAEs, the reliability of the MOCR was much better for broadband measurements than for half-octave-band filtered estimates. At the same time, the reliability of MOCR in half-octave bands was higher for TBOAEs than for CEOAEs, especially at 2 and 4 kHz. CONCLUSIONS For general applications where broadband MOCR is of interest, the highest magnitude and reliability is provided by CEOAEs. However, TBOAEs may be better if a particular frequency band is of interest.
Collapse
Affiliation(s)
- W Wiktor Jedrzejczak
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland
- World Hearing Center, Kajetany, Nadarzyn, Poland
| | - Edyta Pilka
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland
- World Hearing Center, Kajetany, Nadarzyn, Poland
| | - Malgorzata Pastucha
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland
- World Hearing Center, Kajetany, Nadarzyn, Poland
| | - Henryk Skarzynski
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland
- World Hearing Center, Kajetany, Nadarzyn, Poland
| | - Krzysztof Kochanek
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland
- World Hearing Center, Kajetany, Nadarzyn, Poland
| |
Collapse
|
4
|
Carney LH. Neural Fluctuation Contrast as a Code for Complex Sounds: The Role and Control of Peripheral Nonlinearities. Hear Res 2024; 443:108966. [PMID: 38310710 PMCID: PMC10923127 DOI: 10.1016/j.heares.2024.108966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/14/2024] [Accepted: 01/26/2024] [Indexed: 02/06/2024]
Abstract
The nonlinearities of the inner ear are often considered to be obstacles that the central nervous system has to overcome to decode neural responses to sounds. This review describes how peripheral nonlinearities, such as saturation of the inner-hair-cell response and of the IHC-auditory-nerve synapse, are instead beneficial to the neural encoding of complex sounds such as speech. These nonlinearities set up contrast in the depth of neural-fluctuations in auditory-nerve responses along the tonotopic axis, referred to here as neural fluctuation contrast (NFC). Physiological support for the NFC coding hypothesis is reviewed, and predictions of several psychophysical phenomena, including masked detection and speech intelligibility, are presented. Lastly, a framework based on the NFC code for understanding how the medial olivocochlear (MOC) efferent system contributes to the coding of complex sounds is presented. By modulating cochlear gain control in response to both sound energy and fluctuations in neural responses, the MOC system is hypothesized to function not as a simple feedback gain-control device, but rather as a mechanism for enhancing NFC along the tonotopic axis, enabling robust encoding of complex sounds across a wide range of sound levels and in the presence of background noise. Effects of sensorineural hearing loss on the NFC code and on the MOC feedback system are presented and discussed.
Collapse
Affiliation(s)
- Laurel H Carney
- Depts. of Biomedical Engineering, Neuroscience, and Electrical & Computer Engineering University of Rochester, Rochester, NY, USA.
| |
Collapse
|
5
|
Cacace AT, Berri B. Blast Overpressures as a Military and Occupational Health Concern. Am J Audiol 2023; 32:779-792. [PMID: 37713532 DOI: 10.1044/2023_aja-23-00125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/17/2023] Open
Abstract
PURPOSE This tutorial reviews effects of environmental stressors like blast overpressures and other well-known acoustic contaminants (continuous, intermittent, and impulsive noise) on hearing, tinnitus, vestibular, and balance-related functions. Based on the overall outcome of these effects, detailed consideration is given to the health and well-being of individuals. METHOD Because hearing loss and tinnitus are consequential in affecting quality of life, novel neuromodulation paradigms are reviewed for their positive abatement and treatment-related effects. Examples of clinical data, research strategies, and methodological approaches focus on repetitive transcranial magnetic stimulation (rTMS) and electrical stimulation of the vagus nerve paired with tones (VNSt) for their unique contributions to this area. RESULTS Acoustic toxicants transmitted through the atmosphere are noteworthy for their propensity to induce hearing loss and tinnitus. Mounting evidence also indicates that high-level rapid onset changes in atmospheric sound pressure can significantly impact vestibular and balance function. Indeed, the risk of falling secondary to loss of, or damage to, sensory receptor cells in otolith organs (utricle and saccule) is a primary reason for this concern. As part of the complexities involved in VNSt treatment strategies, vocal dysfunction may also manifest. In addition, evaluation of temporospatial gait parameters is worthy of consideration based on their ability to detect and monitor incipient neurological disease, cognitive decline, and mortality. CONCLUSION Highlighting these respective areas underscores the need to enhance information exchange among scientists, clinicians, and caregivers on the benefits and complications of these outcomes.
Collapse
Affiliation(s)
- Anthony T Cacace
- Department of Communication Sciences & Disorders, Wayne State University, Detroit, MI
| | - Batoul Berri
- Department of Communication Sciences & Disorders, Wayne State University, Detroit, MI
- Department of Otolaryngology, University of Michigan, Ann Arbor
| |
Collapse
|
6
|
Gafoor SA, Uppunda AK. Speech Perception in Noise and Medial Olivocochlear Reflex: Effects of Age, Speech Stimulus, and Response-Related Variables. J Assoc Res Otolaryngol 2023; 24:619-631. [PMID: 38079021 PMCID: PMC10752852 DOI: 10.1007/s10162-023-00919-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 11/20/2023] [Indexed: 12/29/2023] Open
Abstract
PURPOSE The role of the medial olivocochlear system in speech perception in noise has been debated over the years, with studies showing mixed results. One possible reason for this could be the dependence of this relationship on the parameters used in assessing the speech perception ability (age, stimulus, and response-related variables). METHODS The current study assessed the influence of the type of speech stimuli (monosyllables, words, and sentences), the signal-to-noise ratio (+5, 0, -5, and -10 dB), the metric used to quantify the speech perception ability (percent-correct, SNR-50, and slope of the psychometric function) and age (young vs old) on the relationship between medial olivocochlear reflex (quantified by contralateral inhibition of transient evoked otoacoustic emissions) and speech perception in noise. RESULTS A linear mixed-effects model revealed no significant contributions of the medial olivocochlear reflex to speech perception in noise. CONCLUSION The results suggest that there was no evidence of any modulatory influence of the indirectly measured medial olivocochlear reflex strength on speech perception in noise.
Collapse
Affiliation(s)
- Shezeen Abdul Gafoor
- Facility for Advanced Auditory Research, Department of Audiology, All India Institute of Speech and Hearing, Mysuru, India
| | - Ajith Kumar Uppunda
- Department of Audiology, All India Institute of Speech and Hearing, Manasagangothri, Mysuru, India, 570006.
| |
Collapse
|
7
|
Farhadi A, Jennings SG, Strickland EA, Carney LH. Subcortical auditory model including efferent dynamic gain control with inputs from cochlear nucleus and inferior colliculus. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:3644-3659. [PMID: 38051523 PMCID: PMC10836963 DOI: 10.1121/10.0022578] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 10/21/2023] [Accepted: 11/13/2023] [Indexed: 12/07/2023]
Abstract
An auditory model has been developed with a time-varying, gain-control signal based on the physiology of the efferent system and subcortical neural pathways. The medial olivocochlear (MOC) efferent stage of the model receives excitatory projections from fluctuation-sensitive model neurons of the inferior colliculus (IC) and wide-dynamic-range model neurons of the cochlear nucleus. The response of the model MOC stage dynamically controls cochlear gain via simulated outer hair cells. In response to amplitude-modulated (AM) noise, firing rates of most IC neurons with band-enhanced modulation transfer functions in awake rabbits increase over a time course consistent with the dynamics of the MOC efferent feedback. These changes in the rates of IC neurons in awake rabbits were employed to adjust the parameters of the efferent stage of the proposed model. Responses of the proposed model to AM noise were able to simulate the increasing IC rate over time, whereas the model without the efferent system did not show this trend. The proposed model with efferent gain control provides a powerful tool for testing hypotheses, shedding insight on mechanisms in hearing, specifically those involving the efferent system.
Collapse
Affiliation(s)
- Afagh Farhadi
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York 14642, USA
| | - Skyler G Jennings
- Department of Communication Sciences and Disorders, University of Utah, Salt Lake City, Utah 84112, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Laurel H Carney
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14642, USA
| |
Collapse
|
8
|
Gafoor SA, Uppunda AK. Role of the medial olivocochlear efferent auditory system in speech perception in noise: a systematic review and meta-analyses. Int J Audiol 2023:1-9. [PMID: 37791429 DOI: 10.1080/14992027.2023.2260951] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Accepted: 09/14/2023] [Indexed: 10/05/2023]
Abstract
OBJECTIVE The study investigated the relationship between the strength of the medial olivocochlear reflex (measured via contralateral inhibition of otoacoustic emissions) and speech perception in noise (obtained from behavioural identification task) through meta-analyses. DESIGN A systematic review and random-effects meta-analysis of studies investigating the relationship in neurotypical adults was performed. STUDY SAMPLE The systematic search (in PubMed, Scopus, Science Direct and Google Scholar databases) revealed 21 eligible studies, which were critically appraised using the NIH tool for Observational Cohort and Cross-Sectional Studies. Meta-analysis was performed on 17 studies (374 participants) with fair to good quality. RESULTS The results revealed that the medial olivocochlear reflex accounts for less than 1% of the variations in speech perception in noise in neurotypical individuals. Sub-group analyses conducted to address a few methodological differences also revealed no discernible association between the two variables. CONCLUSIONS The results reveal no modulatory effect of the medial olivocochlear reflex assessed using contralateral inhibition of otoacoustic emission on the ability to perceive speech in noise. However, more data utilising alternative measures of medial olivocochlear reflex strength is necessary before drawing any conclusions about the role of the medial olivocochlear bundle in speech perception in noise.
Collapse
Affiliation(s)
- Shezeen Abdul Gafoor
- Department of Audiology, All India Institute of Speech and Hearing, Mysuru, India
| | - Ajith Kumar Uppunda
- Department of Audiology, All India Institute of Speech and Hearing, Mysuru, India
| |
Collapse
|
9
|
Ruba S, Panda MR. Short-Term and Long-Term Stability of Medial Olivocochlear Reflex in Adults with Typical Hearing. Indian J Otolaryngol Head Neck Surg 2023; 75:297-300. [PMID: 37206843 PMCID: PMC10188698 DOI: 10.1007/s12070-022-03448-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Accepted: 12/25/2022] [Indexed: 01/03/2023] Open
Abstract
This study aimed to assess the stability of Medial Olivocochlear Reflex (MOCR) function in typical hearing adults with the use of Contralateral Suppression (CS) of Distortion Product Otoacoustic Emissions (DPOAEs). This study included fifty-three (90 ears) participants between the ages of 18-30. Participants were divided into 3 groups (Group A-daily stability, Group B-short-term stability, and Group C- long-term stability). For each group, 4 measurements (30 × 4 = 120sessions) were taken. Group A measurements were taken daily, Group B measurements were taken weekly and Group C measurements were taken monthly. DPOAEs and Contralateral Suppression of DPOAEs were measured for each group. Analyses indicated that Medial Olivocochlear Reflex (MOCR) measured through contralateral suppression of DPOAE was unstable. This result indicates a DPOAE-based measure of the MOCR was not repeated across time. A great deal has been learned using CS of DPOAEs to study medial efferent activation, but several unresolved methodological issues that could impact the data to produce poor stability across time. Those methodological issues need to be explored and researched in the future.
Collapse
Affiliation(s)
- S. Ruba
- Department of Audiology and Speech Language Pathology, SRM Medical College Hospital and Research Centre, SRM Institute of Science and Technology, Kattankulathur Campus, Chennai, Tamilnadu 603203 India
| | | |
Collapse
|
10
|
Salloom WB, Bharadwaj H, Strickland EA. The effects of broadband elicitor duration on a psychoacoustic measure of cochlear gain reduction. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:2482. [PMID: 37092950 PMCID: PMC10257528 DOI: 10.1121/10.0017925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/31/2023] [Accepted: 04/07/2023] [Indexed: 05/03/2023]
Abstract
Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long duration elicitors (>100 ms). This is largely due to previous research using otoacoustic emissions (OAEs) that found multiple MOCR time constants, including time constants in the 100s of milliseconds, when elicited by broadband noise. However, the effect of the duration of a broadband noise elicitor on similar psychoacoustic tasks is currently unknown. The current study measured the effects of ipsilateral broadband noise elicitor duration on psychoacoustic gain reduction estimated from a forward-masking paradigm. Analysis showed that both masker type and elicitor duration were significant main effects, but no interaction was found. Gain reduction time constants were ∼46 ms for the masker present condition and ∼78 ms for the masker absent condition (ranging from ∼29 to 172 ms), both similar to the fast time constants reported in the OAE literature (70-100 ms). Maximum gain reduction was seen for elicitor durations of ∼200 ms. This is longer than the 50-ms duration which was found to produce maximum gain reduction with a tonal on-frequency elicitor. Future studies of gain reduction may use 150-200 ms broadband elicitors to maximally or near-maximally stimulate the MOCR.
Collapse
Affiliation(s)
- William B Salloom
- Department of Speech Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Hari Bharadwaj
- Department of Speech Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| |
Collapse
|
11
|
Brennan MA, Svec A, Farhadi A, Maxwell BN, Carney LH. Inherent envelope fluctuations in forward masking: Effects of age and hearing loss. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:1994. [PMID: 37092921 PMCID: PMC10071988 DOI: 10.1121/10.0017724] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 05/03/2023]
Abstract
Forward masking is generally greater for Gaussian noise (GN) than for low-fluctuation noise maskers, i.e., GN disruption. Because the minimal hearing loss that is associated with older age may affect GN disruption differently than more significant hearing loss, the current study explored the contribution of minimal hearing loss associated with older age to GN disruption. GN disruption was measured using three masker-signal delays (25, 75, and 150 ms) for three adult groups: younger participants with normal hearing (NH), older participants with minimal hearing loss, and older participants with sensorineural hearing loss. The role of underlying mechanisms was tested using a computational model for midbrain neurons. The primary result suggests that older listeners with mild threshold elevations that typically occur with age may be more susceptible to the deleterious effects of masker envelope fluctuations than younger listeners with NH. Results from the computational model indicate that there may be a larger influence of efferent feedback and saturation of inner hair cells on forward masking and GN disruption than previously considered.
Collapse
Affiliation(s)
- Marc A Brennan
- University of Nebraska-Lincoln, Lincoln, Nebraska 68583, USA
| | - Adam Svec
- San José State University, San Jose, California 95192, USA
| | - Afagh Farhadi
- University of Rochester, Rochester, New York 14642, USA
| | | | | |
Collapse
|
12
|
Jennings SG, Aviles ES. Middle ear muscle and medial olivocochlear activity inferred from individual human ears via cochlear potentials. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:1723. [PMID: 37002081 PMCID: PMC10019909 DOI: 10.1121/10.0017604] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 02/23/2023] [Accepted: 02/25/2023] [Indexed: 05/18/2023]
Abstract
The peripheral auditory system is influenced by the medial olivocochlear (MOC) and middle ear muscle (MEM) reflexes. When elicited by contralateral acoustic stimulation (CAS), these reflexes reduce cochlear amplification (MOC reflex) and limit low-frequency transmission through the middle ear (MEM reflex). The independent roles of these reflexes on auditory physiology and perception are difficult to distinguish. The amplitude of the cochlear microphonic (CM) is expected to increase or decrease when the MOC and MEM reflexes are elicited by CAS, respectively, which could lead to a straightforward interpretation of what reflex is dominant for a given CAS level. CM and ear canal sound pressure level (SPL) were measured for a 500 Hz, 90 dB SPL probe in the presence of contralateral broadband noise (CBBN) for levels ranging from 45-75 dB SPL. In most subjects, CM amplitude increased for CBBN levels of 45 and 55 dB SPL, while no change in ear canal SPL was observed, consistent with eliciting the MOC reflex. Conversely, CM amplitude decreased, and ear canal SPL increased in the presence of 65 and 75 dB SPL CBBN, consistent with eliciting the MEM reflex. A CM-based test of the MOC reflex may facilitate detection of MEM effects and the assessment of adults with cochlear hearing loss.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, Utah 84112, USA
| | - Elizabeth Sarai Aviles
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, Utah 84112, USA
| |
Collapse
|
13
|
Jennings SG, Dominguez J. Firing Rate Adaptation of the Human Auditory Nerve Optimizes Neural Signal-to-Noise Ratios. J Assoc Res Otolaryngol 2022; 23:365-378. [PMID: 35254540 PMCID: PMC9085988 DOI: 10.1007/s10162-022-00841-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 02/14/2022] [Indexed: 10/18/2022] Open
Abstract
Several physiological mechanisms act on the response of the auditory nerve (AN) during acoustic stimulation, resulting in an adjustment in auditory gain. These mechanisms include-but are not limited to-firing rate adaptation, dynamic range adaptation, the middle ear muscle reflex, and the medial olivocochlear reflex. A potential role of these mechanisms is to improve the neural signal-to-noise ratio (SNR) at the output of the AN in real time. This study tested the hypothesis that neural SNRs, inferred from non-invasive assessment of the human AN, improve over the duration of acoustic stimulation. Cochlear potentials were measured in response to a series of six high-level clicks embedded in a series of six lower-level broadband noise bursts. This paradigm elicited a compound action potential (CAP) in response to each click and to the onset of each noise burst. The ratio of CAP amplitudes elicited by each click and noise burst pair (i.e., neural SNR) was tracked over the six click/noise bursts. The main finding was a rapid (< 24 ms) increase in neural SNR from the first to the second click/noise burst, consistent with a real-time adjustment in the response of the auditory periphery toward improving the SNR of the signal transmitted to the brainstem. Analysis of cochlear microphonic and ear canal sound pressure recordings, as well as the time course for this improvement in neural SNR, supports the conclusion that firing rate adaptation is likely the primary mechanism responsible for improving neural SNR, while dynamic range adaptation, the middle ear muscle reflex, and the medial olivocochlear reflex played a secondary role on the effects observed in this study. Real-time improvements in neural SNR are significant because they may be essential for robust encoding of speech and other relevant stimuli in the presence of background noise.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA.
| | - Juan Dominguez
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA
| |
Collapse
|
14
|
Marrufo-Pérez MI, Lopez-Poveda EA. Adaptation to noise in normal and impaired hearing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:1741. [PMID: 35364964 DOI: 10.1121/10.0009802] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 02/26/2022] [Indexed: 06/14/2023]
Abstract
Many aspects of hearing function are negatively affected by background noise. Listeners, however, have some ability to adapt to background noise. For instance, the detection of pure tones and the recognition of isolated words embedded in noise can improve gradually as tones and words are delayed a few hundred milliseconds in the noise. While some evidence suggests that adaptation to noise could be mediated by the medial olivocochlear reflex, adaptation can occur for people who do not have a functional reflex. Since adaptation can facilitate hearing in noise, and hearing in noise is often harder for hearing-impaired than for normal-hearing listeners, it is conceivable that adaptation is impaired with hearing loss. It remains unclear, however, if and to what extent this is the case, or whether impaired adaptation contributes to the greater difficulties experienced by hearing-impaired listeners understanding speech in noise. Here, we review adaptation to noise, the mechanisms potentially contributing to this adaptation, and factors that might reduce the ability to adapt to background noise, including cochlear hearing loss, cochlear synaptopathy, aging, and noise exposure. The review highlights few knowns and many unknowns about adaptation to noise, and thus paves the way for further research on this topic.
Collapse
Affiliation(s)
- Miriam I Marrufo-Pérez
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007 Salamanca, Spain
| | - Enrique A Lopez-Poveda
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007 Salamanca, Spain
| |
Collapse
|
15
|
DeRoy Milvae K, Strickland EA. Behavioral Measures of Cochlear Gain Reduction Depend on Precursor Frequency, Bandwidth, and Level. Front Neurosci 2021; 15:716689. [PMID: 34671236 PMCID: PMC8520990 DOI: 10.3389/fnins.2021.716689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 09/06/2021] [Indexed: 11/25/2022] Open
Abstract
Sensory systems adjust to the environment to maintain sensitivity to change. In the auditory system, the medial olivocochlear reflex (MOCR) is a known physiological mechanism capable of such adjustment. The MOCR provides efferent feedback between the brainstem and cochlea, reducing cochlear gain in response to sound. The perceptual effects of the MOCR are not well understood, such as how gain reduction depends on elicitor characteristics in human listeners. Physiological and behavioral data suggest that ipsilateral MOCR tuning is only slightly broader than it is for afferent fibers, and that the fibers feed back to the frequency region of the cochlea that stimulated them. However, some otoacoustic emission (OAE) data suggest that noise is a more effective elicitor than would be consistent with sharp tuning, and that a broad region of the cochlea may be involved in elicitation. If the elicitor is processed in a cochlear channel centered at the signal frequency, the growth of gain reduction with elicitor level would be expected to depend on the frequency content of the elicitor. In the current study, the effects of the frequency content and level of a preceding sound (called a precursor) on signal threshold was examined. The results show that signal threshold increased with increasing precursor level at a shallower slope for a tonal precursor at the signal frequency than for a tonal precursor nearly an octave below the signal frequency. A broadband noise was only slightly more effective than a tone at the signal frequency, with a relatively shallow slope similar to that of the tonal precursor at the signal frequency. Overall, these results suggest that the excitation at the signal cochlear place, regardless of elicitor frequency, determines the magnitude of ipsilateral cochlear gain reduction, and that it increases with elicitor level.
Collapse
Affiliation(s)
- Kristina DeRoy Milvae
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN, United States
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN, United States
| |
Collapse
|
16
|
Salloom WB, Strickland EA. The effect of broadband elicitor laterality on psychoacoustic gain reduction across signal frequency. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:2817. [PMID: 34717476 PMCID: PMC8520488 DOI: 10.1121/10.0006662] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 05/19/2023]
Abstract
There are psychoacoustic methods thought to measure gain reduction, which may be from the medial olivocochlear reflex (MOCR), a bilateral feedback loop that adjusts cochlear gain. Although studies have used ipsilateral and contralateral elicitors and have examined strength at different signal frequencies, these factors have not been examined within a single study. Therefore, basic questions about gain reduction, such as the relative strength of ipsilateral vs contralateral elicitation and the relative strength across signal frequency, are not known. In the current study, gain reduction from ipsilateral, contralateral, and bilateral elicitors was measured at 1-, 2-, and 4-kHz signal frequencies using forward masking paradigms at a range of elicitor levels in a repeated measures design. Ipsilateral and bilateral strengths were similar and significantly larger than contralateral strength across signal frequencies. Growth of gain reduction with precursor level tended to differ with signal frequency, although not significantly. Data from previous studies are considered in light of the results of this study. Behavioral results are also considered relative to anatomical and physiological data on the MOCR. These results indicate that, in humans, cochlear gain reduction is broad across frequencies and is robust for ipsilateral and bilateral elicitation but small for contralateral elicitation.
Collapse
Affiliation(s)
- William B Salloom
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| |
Collapse
|