1
|
Srivastava S, Dhyani M, Dighe M. Contrast-enhanced ultrasound (CEUS): applications from the kidneys to the bladder. Abdom Radiol (NY) 2024:10.1007/s00261-024-04388-4. [PMID: 38884782 DOI: 10.1007/s00261-024-04388-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 05/10/2024] [Accepted: 05/13/2024] [Indexed: 06/18/2024]
Abstract
Contrast-enhanced ultrasound (CEUS) is an advanced ultrasound (US) technique utilizing ultrasound contrast agents (UCAs) to provide detailed visualization of anatomic and vascular architecture, including the depiction of microcirculation. CEUS has been well-established in echocardiography and imaging of focal hepatic lesions and recent studies have also shown the utility of CEUS in non-hepatic applications like the urinary system. The updated guidelines by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) from 2018 describe the use of CEUS for non-hepatic applications. CEUS' excellent safety profile and spatial resolution make it a superior modality to conventional US and is often comparable and even superior to CECT in some instances. In comparison to other cross-sectional imaging modalities such as CECT or MRI, CEUS offers a safe (by virtue of non-nephrotoxic US contrast agents), accurate, cost-efficient, readily available, and a quick means of evaluation of multiple pathologies of the urinary system. CEUS also has the potential to reduce the overall economic burden on patients requiring long-term follow-up due to its low cost as compared to CT or MRI techniques. This comprehensive review focuses on the applications of CEUS in evaluating the urinary system from the kidneys to the urinary bladder. CEUS can be utilized in the kidney to evaluate complex cystic lesions, indeterminate lesions, pseudotumors (vs solid renal tumors), renal infections, and renal ischemic disorders. Additionally, CEUS has also been utilized in evaluating renal transplants. In the urinary bladder, CEUS is extremely useful in differentiating a bladder hematoma and bladder cancer when conventional US techniques show equivocal results. Quantitative parameters of time-intensity curves (TICs) of CEUS examinations have also been studied to stage and grade bladder cancers. Although promising, further research is needed to definitively stage bladder cancers and classify them as muscle-invasive or non-muscle invasive using quantitative CEUS to guide appropriate intervention. CEUS has been very effective in the classification of cystic renal lesions, however, further research is needed in differentiating benign from malignant renal masses.
Collapse
Affiliation(s)
- Saubhagya Srivastava
- Department of Radiology, University of Washington, Seattle, Washington, 98195, USA.
| | - Manish Dhyani
- Department of Radiology, University of Washington, Seattle, Washington, 98195, USA
| | - Manjiri Dighe
- Department of Radiology, University of Washington, Seattle, Washington, 98195, USA
| |
Collapse
|
2
|
Staub E. Current and potential methods to assess kidney structure and morphology in term and preterm neonates. Anat Rec (Hoboken) 2023. [PMID: 36883787 DOI: 10.1002/ar.25195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 01/25/2023] [Accepted: 02/21/2023] [Indexed: 03/09/2023]
Abstract
After birth, the kidney structure in neonates adapt to the functional demands of extrauterine life. Nephrogenesis is complete in the third trimester, but glomeruli, tubuli, and vasculature mature with the rapidly increasing renal blood flow and glomerular filtration. In preterm infants, nephrogenesis remains incomplete and maturation is slower and may be aberrant. This structural and functional deficit has life-long consequences: preterm born individuals are at higher risk for chronic kidney disease and arterial hypertension later in life. This review assembles the literature on existing and potential methods to visualize neonatal kidney structure and morphology and explore their potential to longitudinally document the developmental deviation after preterm birth. X-rays with and without contrast, fluoroscopy and computed tomography (CT) involve relevant ionizing radiation exposure and, apart from CT, do not provide sufficient structural details. Ultrasound has evolved into a safe and noninvasive high-resolution imaging method which is excellent for longitudinal observations. Doppler ultrasound modes can characterize and quantify blood flow to and through the kidneys. Microvascular flow imaging has opened new possibilities of visualizing previously unseen vascular structures. Recent advances in magnetic resonance imaging display renal structure and function in unprecedented detail, but are offset by the logistical challenges of the imaging procedure and limited experience with the new techniques in neonates. Kidney biopsies visualize structure histologically, but are too invasive and remain anecdotal in newborns. All the explored methods have predominantly been examined in term newborns and require further research on longitudinal structural observation in the kidneys of preterm infants.
Collapse
Affiliation(s)
- Eveline Staub
- Department of Neonatology, Royal North Shore Hospital, St Leonards, New South Wales, Australia
- University of Sydney Northern Clinical School, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| |
Collapse
|
3
|
Kaykanat SI, Uguz AK. The role of acoustofluidics and microbubble dynamics for therapeutic applications and drug delivery. BIOMICROFLUIDICS 2023; 17:021502. [PMID: 37153864 PMCID: PMC10162024 DOI: 10.1063/5.0130769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 03/18/2023] [Indexed: 05/10/2023]
Abstract
Targeted drug delivery is proposed to reduce the toxic effects of conventional therapeutic methods. For that purpose, nanoparticles are loaded with drugs called nanocarriers and directed toward a specific site. However, biological barriers challenge the nanocarriers to convey the drug to the target site effectively. Different targeting strategies and nanoparticle designs are used to overcome these barriers. Ultrasound is a new, safe, and non-invasive drug targeting method, especially when combined with microbubbles. Microbubbles oscillate under the effect of the ultrasound, which increases the permeability of endothelium, hence, the drug uptake to the target site. Consequently, this new technique reduces the dose of the drug and avoids its side effects. This review aims to describe the biological barriers and the targeting types with the critical features of acoustically driven microbubbles focusing on biomedical applications. The theoretical part covers the historical developments in microbubble models for different conditions: microbubbles in an incompressible and compressible medium and bubbles encapsulated by a shell. The current state and the possible future directions are discussed.
Collapse
Affiliation(s)
- S. I. Kaykanat
- Department of Chemical Engineering, Boğaziçi University, 34342 Bebek, Istanbul, Türkiye
| | | |
Collapse
|
4
|
Aggarwal A, Das CJ, Sharma S. Recent advances in imaging techniques of renal masses. World J Radiol 2022; 14:137-150. [PMID: 35978979 PMCID: PMC9258310 DOI: 10.4329/wjr.v14.i6.137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 03/04/2022] [Accepted: 06/17/2022] [Indexed: 02/06/2023] Open
Abstract
Multiphasic multidetector computed tomography (CT) forms the mainstay for the characterization of renal masses whereas magnetic resonance imaging (MRI) acts as a problem-solving tool in some cases. However, a few of the renal masses remain indeterminate even after evaluation by conventional imaging methods. To overcome the deficiency in current imaging techniques, advanced imaging methods have been devised and are being tested. This review will cover the role of contrast-enhanced ultrasonography, shear wave elastography, dual-energy CT, perfusion CT, MR perfusion, diffusion-weighted MRI, blood oxygen level-dependent MRI, MR spectroscopy, positron emission tomography (PET)/prostate-specific membrane antigen-PET in the characterization of renal masses.
Collapse
Affiliation(s)
- Ankita Aggarwal
- Department of Radiology, Vardhman Mahavir Medical College& Safdarjung Hospital, Delhi 110029, India
| | - Chandan J Das
- Department of Radiodiagnosis and Interventional Radiology, All India Institute of Medical Sciences, Delhi 110029, India
| | - Sanjay Sharma
- Department of Radiology (RPC), All India Institute of Medical Sciences, New Delhi 110029, India
| |
Collapse
|
5
|
Cao H, Fang L, Chen L, Zhan J, Diao X, Liu Y, Lu C, Zhang Z, Chen Y. The Value of Contrast-Enhanced Ultrasound in Diagnosing Small Renal Cell Carcinoma Subtypes and Angiomyolipoma. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2022; 41:1415-1423. [PMID: 34499770 DOI: 10.1002/jum.15824] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVES To retrospectively explore the value of contrast-enhanced ultrasound (CEUS) in differentiating small renal cell carcinomas (RCCs) from angiomyolipomas (AMLs), and distinguishing between clear cell RCC (ccRCC), papillary RCC (pRCC), and chromophobe RCC (chRCC). METHODS A total of 151 patients with small renal masses (110 ccRCCs, 12 pRCCs, 9 chRCCs, and 20 AMLs) were enrolled between August 2016 and October 2019. RESULTS There were significant differences in terms of enhancement intensity (EI), enhancement homogeneity, perilesional rim-like enhancement (PRE), wash in, and wash out (WO) between RCC and AML (P = .000, .011, .000, .001, .000, respectively). Although there was no significant difference in EI between pRCC and chRCC (P = .272), EI of ccRCC was higher than that of pRCC (P = .000) and chRCC (P = .010). Multivariate regression analysis showed PRE and fast WO were related to RCC (OR = 18.189, 15.141, respectively). Although there were no significant differences in the sensitivity and area under the curve (AUC) between PRE and fast WO (95.0% vs. 95.0%, P = 1.000 and .880 vs. 0.799, P = .123, respectively), the specificity of PRE in predicting RCC was higher than that of fast WO (80.92% vs. 64.89%, P = .011). The sensitivity, specificity, and AUC of the two characteristics combination for differentiating RCC from AML were 95.0%, 90.8%, and 0.920, respectively, and that of EI for differentiating between ccRCC, pRCC, and chRCC were 81.0%, 78.2%, and 0.796, respectively. CONCLUSIONS CEUS has value in differentiating small RCCs from AMLs and distinguishing ccRCC, a subtype associated with a greater likelihood of malignant behavior from pRCC and chRCC.
Collapse
Affiliation(s)
- Hongli Cao
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| | - Liang Fang
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| | - Lin Chen
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| | - Jia Zhan
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| | - Xuehong Diao
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| | - Yingchun Liu
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| | - Chen Lu
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
- Department of Pathology, Huadong Hospital, Fudan University, Shanghai, China
| | - Zhengwang Zhang
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
- Department of Urology, Huadong Hospital, Fudan University, Shanghai, China
| | - Yue Chen
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Clinical Geriatric Medicine, Shanghai, China
| |
Collapse
|
6
|
Contrast-enhanced ultrasound of the kidneys: principles and potential applications. Abdom Radiol (NY) 2022; 47:1369-1384. [PMID: 35150315 DOI: 10.1007/s00261-022-03438-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/30/2022] [Accepted: 01/31/2022] [Indexed: 02/07/2023]
Abstract
Contrast-enhanced ultrasound (CEUS) is an extension and an enhanced form of ultrasound that allows real-time evaluation of the various structures in different vascular phases. The last decade has witnessed a widespread expansion of CEUS applications beyond the liver. It has shown fair potential in kidneys and its diagnostic efficacy is comparable to CT and MRI. Ultrasound is the well-accepted screening modality for renal pathologies, however, it underperforms in the characterization of the renal masses. CEUS can be beneficial in such cases as it can help in the characterization of such incidental masses in the same sitting. It has an excellent safety profile with no risk of radiation or contract-related nephropathy. It can aid in the correct categorization of renal cysts into one of the Bosniak classes and has proven its worth especially in complex cysts or indeterminate renal masses (especially Bosniak Category IIF and III). Few studies also describe its potential role in solid masses and in differentiating benign from malignant masses. Other areas of interest include infections, infarctions, trauma, follow-up of local ablative procedures, and VUR. Through this review, the readers shall get an insight into the various applications of CEUS in kidneys, with imaging examples.
Collapse
|
7
|
Zhou ZB, Xue YE, Yao YW, Zhang XT, Zhang MH, Yang DX, Xie JH. Role of Sonazoid-based contrast-enhanced ultrasonography in the microwave ablation of primary hyperparathyroidism. Int J Hyperthermia 2022; 39:155-161. [PMID: 35000496 DOI: 10.1080/02656736.2021.2023227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
OBJECTIVES This study aimed to determine the performance of Sonazoid-based contrast-enhanced ultrasound (CEUS) in the microwave ablation (MWA) of primary hyperparathyroidism (pHPT). METHODS Forty patients with pHPT were enrolled and treated with percutaneous ultrasound (US)-guided MWA assisted by CEUS. All patients underwent immediate CEUS examinations following MWA. On post-ablation day 1, patients who did not display a decrease in intact parathyroid hormone (iPTH) levels to the norm were examined by CEUS to evaluate an incomplete ablation. We compared the serum iPTH and calcium levels and the nodule volumes before and after MWA. The complications were evaluated during and after treatment. RESULTS Immediately following MWA, CEUS demonstrated complete ablation with all 44 parathyroid nodules. On post-ablation day 1, five nodules in five patients displayed annular enhancement around the ablation zone on CEUS. The average maximum diameters of the nodules and the ablation zone were 1.09 ± 0.28 cm and 1.36 ± 0.23 cm, respectively. An ablation zone larger than the primary lesion (p < 0.05) generated a higher rate of complete ablation. Compared with pre-MWA, serum iPTH and calcium levels were significantly improved. Treatment success was achieved in 38 patients (95%). Hoarseness was a major complication in six patients (15%); however, it improved spontaneously within 1-4 months. We observed two recurrences (2/40, 5%) at 9 months and 11 months following MWA, respectively. CONCLUSION US-guided percutaneous MWA assisted by CEUS for pHPT is an effective and safe therapy. CEUS can avoid operative failure and improve the cure rate.
Collapse
Affiliation(s)
- Zu-Bang Zhou
- Department of Ultrasound, Gansu Provincial Hospital, Gansu, China
| | - Ya-E Xue
- The First Clinical Medical College of Gansu University of Chinese Medicine, Gansu, China
| | - Yan-Wu Yao
- The First Clinical Medical College of Gansu University of Chinese Medicine, Gansu, China
| | - Xue-Ting Zhang
- The First Clinical Medical College of Gansu University of Chinese Medicine, Gansu, China
| | - Ming-Hua Zhang
- The First Clinical Medical College of Gansu University of Chinese Medicine, Gansu, China
| | - Da-Xiong Yang
- The First Clinical Medical College of Gansu University of Chinese Medicine, Gansu, China
| | - Jin-Hui Xie
- Department of Ultrasound, Gansu Provincial Hospital, Gansu, China
| |
Collapse
|
8
|
Hysi E, Kaur H, Young A. Evolving Medical Imaging Techniques for the Assessment of Delayed Graft Function: A Narrative Review. Can J Kidney Health Dis 2021; 8:20543581211048341. [PMID: 34707880 PMCID: PMC8544764 DOI: 10.1177/20543581211048341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 09/04/2021] [Indexed: 11/15/2022] Open
Abstract
Purpose of review Delayed graft function (DGF) is a significant complication that contributes to poorer graft function and shortened graft survival. In this review, we sought to evaluate the current and emerging role of medical imaging modalities in the assessment of DGF and how it may guide clinical management. Sources of information PubMed, Google Scholar, and ClinicalTrial.gov up until February 2021. Methods This narrative review first examined the pathophysiology of DGF and current clinical management. We then summarized relevant studies that utilized medical imaging to assess posttransplant renal complications, namely, DGF. We focused our attention on noninvasive, evolving imaging modalities with the greatest potential for clinical translation, including contrast-enhanced ultrasound (CEUS) and multiparametric magnetic resonance imaging (MRI). Key findings A kidney biopsy in the setting of DGF can be used to assess the degree of ischemic renal injury and to rule out acute rejection. Biopsies are accompanied by complications and may be limited by sampling bias. Early studies on CEUS and MRI have shown their potential to distinguish between the 2 most common causes of DGF (acute tubular necrosis and acute rejection), but they have generally included only small numbers of patients and have not kept pace with more recent technical advances of these imaging modalities. There remains unharnessed potential with CEUS and MRI, and more robust clinical studies are needed to better evaluate their role in the current era. Limitations The adaptation of emerging approaches for imaging DGF will depend on additional clinical trials to study the feasibility and diagnostic test characteristics of a given modality. This is limited by access to devices, technical competence, and the need for interdisciplinary collaborations to ensure that such studies are well designed to appropriately inform clinical decision-making.
Collapse
Affiliation(s)
- Eno Hysi
- Division of Nephrology, St. Michael's Hospital, Unity Health Toronto, ON, Canada.,Li Ka Shing Knowledge Institute, Keenan Research Centre for Biomedical Sciences, St. Michael's Hospital, Unity Health Toronto, ON, Canada
| | - Harmandeep Kaur
- Li Ka Shing Knowledge Institute, Keenan Research Centre for Biomedical Sciences, St. Michael's Hospital, Unity Health Toronto, ON, Canada
| | - Ann Young
- Division of Nephrology, St. Michael's Hospital, Unity Health Toronto, ON, Canada.,Li Ka Shing Knowledge Institute, Keenan Research Centre for Biomedical Sciences, St. Michael's Hospital, Unity Health Toronto, ON, Canada.,Division of Nephrology, Department of Medicine, University of Toronto, ON, Canada
| |
Collapse
|
9
|
Vičič E, Kojc N, Hovelja T, Arnol M, Ključevšek D. Quantitative contrast-enhanced ultrasound for the differentiation of kidney allografts with significant histopathological injury. Microcirculation 2021; 28:e12732. [PMID: 34570404 DOI: 10.1111/micc.12732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 08/27/2021] [Accepted: 09/20/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To identify specific quantitative contrast-enhanced ultrasound (CEUS) parameters that could distinguish kidney transplants with significant histopathological injury. METHODS Sixty-four patients were enrolled in this prospective observational study. Biopsies were performed following CEUS and blood examination. RESULTS 28 biopsy specimens had minimal changes (MC group), while 36 had significant injury (SI group). Of these, 12 had rejection (RI group) and 24 non-rejection injury (NRI group). In RI and NRI groups, temporal difference in time to peak (TTP) between medulla and cortex (ΔTTPm-c) was significantly shorter compared to the MC group (5.77, 5.92, and 7.94 s, P = 0.048 and 0.026, respectively). Additionally, RI group had significantly shorter medullary TTP compared to the MC group (27.75 vs. 32.26 s; P = 0.03). In a subset of 41 patients with protocol biopsy at 1-year post-transplant, ΔTTPm-c was significantly shorter in the SI compared to the MC group (5.67 vs. 7.67 s; P = 0.024). Area under receiver operating characteristic curves (AUROCs) for ΔTTPm-c was 0.69 in all patients and 0.71 in patients with protocol biopsy. CONCLUSIONS RI and NRI groups had shorter ΔTTPm-c compared to the MC group. AUROCs for both patient groups were good, making ΔTTPm-c a promising CEUS parameter for distinguishing patients with significant histopathological injury.
Collapse
Affiliation(s)
- Eva Vičič
- Department of Radiology, Dr. Franc Derganc General Hospital Nova Gorica, Nova Gorica, Slovenia.,Clinical Institute of Radiology, University Medical Center Ljubljana, Ljubljana, Slovenia
| | - Nika Kojc
- Institute of Pathology, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Tomaž Hovelja
- Information Systems Laboratory, Faculty of Computer and Information Science, University of Ljubljana, Ljubljana, Slovenia
| | - Miha Arnol
- Department of Nephrology, Center for Kidney Transplantation, University Medical Center Ljubljana, Ljubljana, Slovenia.,Department of Internal Medicine, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Damjana Ključevšek
- Department of Radiology, University Children's Hospital Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
10
|
Abstract
With the ever increasing trend of using cross-section imaging in today's era, incidental detection of small solid renal masses has dramatically multiplied. Coincidentally, the number of asymptomatic benign lesions being detected has also increased. The role of radiologists is not only to identify these lesions, but also go a one step further and accurately characterize various renal masses. Earlier detection of small renal cell carcinomas means identifying at the initial stage which has an impact on prognosis, patient management and healthcare costs. In this review article we share our experience with the typical and atypical solid renal masses encountered in adults in routine daily practice.
Collapse
Affiliation(s)
- Mahesh Kumar Mittal
- Department of Radiodiagnosis, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India
| | - Binit Sureka
- Department of Radiology, Institute of Liver and Biliary Sciences, New Delhi, India
| |
Collapse
|
11
|
Zitouni K, Steyn MRCP, Lyka E, Kelly FJ, Cook P, Ster IC, Earle KA. Derepression of glomerular filtration, renal blood flow and antioxidant defence in patients with type 2 diabetes at high-risk of cardiorenal disease. Free Radic Biol Med 2020; 161:283-289. [PMID: 33039650 DOI: 10.1016/j.freeradbiomed.2020.10.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 09/28/2020] [Accepted: 10/03/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND The role of antioxidant status on microvascular blood flow and glomerular filtration (eGFR) in patients with type 2 diabetes and hypertension whose risk of progressive renal disease varies by ethnicity is unknown. METHODS Adult, non-Caucasian (n = 101) and Caucasian (n = 69) patients with type 2 diabetes, hypertension and/or microalbuminuria and an eGFR > 45 mL/min/1.73 m2 were randomised to receive 400 IU vitamin E and/or 20 μg selenium daily or matching placebo. eGFR (CKD-EPI) was measured at baseline, 3,6 and 12 months and renal blood flow by contrast-enhanced ultrasonography in a sub-group (n = 9) at baseline and 3 months by assessing the area under the time intensity curve (TIC). Circulating glutathione peroxidase 3 (GPx-3) activity was measured as a biomarker of oxidative defence status. RESULTS The time to change in eGFR was shortest with combined vitamin E and selenium than usual care (5.6 [4.0-7.0] vs 8.9 [6.8-10.9 months]; p = 0.006). Area under the TIC was reduced compared to baseline (38.52 [22.41-90.49] vs 123 [86.98-367.03]dB.s; P ≤ 0.05 and 347 [175.88-654.92] vs 928.03 [448.45-1683]dB.s; P ≤ 0.05, respectively] at 3 months suggesting an increase in rate of perfusion. The proportional change in eGFR at 12 months was greater in the group whose GPx-3 activity was above, compared with those below the cohort median (360 U/L) in the non-Caucasian and the Caucasian groups (19.1(12.5-25.7] % vs 6.5[-3.5 to 16.5] % and 12.8 [0.7 to 24] % vs 0.2 [-6.1 to 6.5] %). CONCLUSION In these patients with type 2 diabetes and early CKD, antioxidant treatment derepresses renal blood flow and a rise in eGFR correlated directly with GPx-3 activity. SIGNIFICANCE Diabetes mellitus is the world's leading cause of end-stage renal disease which has a predilection for black and minor ethnic groups compared with Caucasians. The differences in risk despite the benefits of conventional care may be related to oxidative stress. We found that glomerular filtration and renal blood flow is suppressed when renal function is preserved in high-risk patients with type 2 diabetes. Conventional care supplemented with selenium - the co-factor for glutathione peroxidase-3 (GPx-3) - improves renal perfusion and increase glomerular filtration according to host antioxidant defence determined by GPx-3 activity. Circulating GPx-3 activity warrants further investigation as a novel biomarker of reversible haemodynamic changes in early diabetic kidney disease to better enable targeting of renoprotective strategies.
Collapse
Affiliation(s)
- Karima Zitouni
- St Georges University of London, Institute of Infection and Immunity, London, UK
| | - M R C P Steyn
- St Georges University Hospitals NHS Foundation Trust, Thomas Addison Unit, London, UK
| | - Eliza Lyka
- St Georges University of London, Institute of Biomedical & Medical Education, London, UK
| | - Frank J Kelly
- Kings College London, Analytical, Environmental and Forensic Sciences Department, London, UK
| | - Paul Cook
- University Hospital Southampton NHS Foundation Trust, Trace Element Unit, Southampton, UK
| | - Irina Chis Ster
- St Georges University of London, Institute of Infection and Immunity, London, UK
| | - Kenneth Anthony Earle
- St Georges University Hospitals NHS Foundation Trust, Thomas Addison Unit, London, UK; St Georges University of London, Institute of Biomedical & Medical Education, London, UK.
| |
Collapse
|
12
|
Bădulescu MR, Socaciu MA, Moisoiu T, Andries A, Iacob G, Badea R. Current status of imaging diagnosis in the transplanted kidney. A review of the literature with a special focus on contrast-enhanced ultrasonography. Med Pharm Rep 2020; 93:133-144. [PMID: 32478319 PMCID: PMC7243885 DOI: 10.15386/mpr-1536] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 01/27/2020] [Accepted: 02/17/2020] [Indexed: 12/15/2022] Open
Abstract
Objectives Ultrasonographic scanning is currently the most widespread imaging diagnostic procedure. The method provides real-time morphological, vascular and elastographic information in a non-invasive manner. In recent years, harmonic vascular examination has become accessible using intravenous contrast agents. In urological pathology, this procedure is used in the detection and evaluation of vascular and ischemic complications, in the classification of complex cysts according to the Bosniak system, also in the renal lesions with uncertain etiology and in acute pyelonephritis for the detection of abscesses. The contrast agent (SonoVue) is angiospecific and can be used in patients transplanted immediately after surgery without adverse effects or impaired renal function. Thus, it is desirable to be used in the nephrological pathology of the renal graft and to develop diagnostic models based on the evaluation of renal microvascularization, as well as the quantitative data resulting from the graphical representation of the specific parameters. The purpose of this review is to evaluate the current state of the literature regarding the place and role of contrast substance ultrasound in the early diagnosis of acute renal graft dysfunction and to make a differential diagnosis of this pathological entity. Method This review quantifies the role of contrast ultrasound in the diagnosis of acute complications of the renal graft. The research was conducted based on the databases PubMed, MedScape, Cochrane, according to the search criteria such as contrast-enhanced ultrasound + kidney transplant, “time intensity curves” + “kidney transplant”, filtered for the period 2004–2018. Results In the nephrological pathology of the renal graft, contrast-enhanced ultrasound is a valuable tool, superior to Doppler ultrasound in predicting the evolution of the renal graft, identifying very small early defects in renal microvascularization. A number of studies succeeded in identifying acute graft dysfunction, some of which establish its etiology - humoral rejection versus acute tubular necrosis. On the other hand, the contrast-enhanced ultrasound parameters do not have the ability to distinguish between cellular and humoral rejection. Conclusions If, at present, the histopathological examination is the only one that can differentiate with certainty the cause of acute renal graft dysfunction, we consider that contrast-enhanced ultrasound, as a non-invasive imaging technique, opens a favorable perspective for increasing the survival of the renal graft and decreasing the complications in the renal transplant. The combination of other ultrasound techniques, together with contrast-enhanced ultrasound, could lead to the development of new diagnostic models.
Collapse
Affiliation(s)
- Maria Ramona Bădulescu
- Hemodialysis Department, 5 Medical Clinic and Urology Department. Clinical Institute of Urology and Renal Transplantation, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Mihai Adrian Socaciu
- Medical Imaging Department, "Octavian Fodor" Institute of Gastroenterology and Hepatology and Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Tudor Moisoiu
- Urology Department, Clinical Institute of Urology and Renal Transplantation, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alexandra Andries
- Medical Imaging Department, "Octavian Fodor" Institute of Gastroenterology and Hepatology and Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.,Medical Imaging Department, "Prof dr. Ion Chiricuta" Institute of Oncology, Cluj-Napoca, Romania
| | - Gheorghiţă Iacob
- Morphology Department, Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca. Romania
| | - Radu Badea
- Medical Imaging Department, "Octavian Fodor" Institute of Gastroenterology and Hepatology and Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|
13
|
Li Q, Wang Z, Ma X, Tang J, Luo Y. Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma. Int Braz J Urol 2020; 46:92-100. [PMID: 31851465 PMCID: PMC6968914 DOI: 10.1590/s1677-5538.ibju.2019.0304] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Accepted: 08/11/2019] [Indexed: 12/12/2022] Open
Abstract
PURPOSE To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). MATERIALS AND METHODS We retrospectively investigated 30 consecutive patients who underwent robot-assisted radical nephrectomy with IVC thrombectomy and had pathologically confirmed RCC. All patients underwent US and CEUS examination. Two offline readers observed and recorded thrombus imaging information and enhancement patterns. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value for bland thrombus were assessed. RESULTS Of the 30 patients, no adverse events occurred during administration of the contrast agent. Early enhancement of the mass within the IVC lumen on CEUS was na indicator of tumor thrombus. Bland thrombus showed no intraluminal flow on CEUS. There were eight (26.7%) patients with bland thrombus, including three level II, two level III, and three level IV. There were three cases with cephalic bland thrombus and five cases with caudal bland thrombus. Three caudal bland thrombi extended to the iliac vein and underwent surgical IVC interruption. Based on no intraluminal flow, for bland thrombus, CEUS had 87.5% sensitivity, 100% specificity, 96.7% accuracy, 100% positive predictive value and 95.6% negative predictive value. CONCLUSION Our study demonstrates the potential of CEUS in the differentiation of bland and tumor thrombus of the IVC in patients with RCC. Since CEUS is an effective, inexpensive, and non-invasive method, it could be a reliable tool in the evaluation of IVC thrombus in patients with RCC.
Collapse
Affiliation(s)
- Qiuyang Li
- Department of Ultrasound, Chinese PLA General Hospital, Beijing 100853, China
| | - Zhongxin Wang
- Department of Urology, Chinese PLA General Hospital, Beijing 100853, China
| | - Xin Ma
- Department of Urology, Chinese PLA General Hospital, Beijing 100853, China
| | - Jie Tang
- Department of Ultrasound, Chinese PLA General Hospital, Beijing 100853, China
| | - Yukun Luo
- Department of Ultrasound, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
14
|
Jin L, Xie F. Untargeted Contrast-Enhanced Ultrasound Versus Contrast-Enhanced Computed Tomography: A Differential Diagnostic Performance (DDP) Study for Kidney Lesions. Clinics (Sao Paulo) 2020; 75:e1489. [PMID: 32130354 PMCID: PMC7026943 DOI: 10.6061/clinics/2020/e1489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2019] [Accepted: 12/13/2019] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES Histopathology is the 'gold standard' for diagnosing renal cell carcinoma but is limited by sample size. Contrast-enhanced ultrasound can differentiate malignant and benign lesions, but the Chinese guidelines on the management of renal cell carcinoma do not include this method. The purpose of this study was to compare the diagnostic parameters of contrast-enhanced ultrasound against those of contrast-enhanced computed tomography for detecting kidney lesions, with histopathology considered the reference standard. METHODS Patients with suspected kidney lesions from prior grayscale ultrasonography and computed tomography were included in the analysis (n=191). The contrast-enhanced ultrasound, contrast-enhanced computed tomography, and histopathology data were collected and analyzed. A solid, enhanced mass was considered a malignant lesion, and an unenhanced mass or cyst was considered a benign lesion. The Bosniak criteria were used to characterize the lesions. RESULTS Contrast-enhanced ultrasound and contrast-enhanced computed tomography both detected that 151 patients had malignant tumors and 40 patients had benign tumors. No significant differences in the tumors and their subtypes were reported between contrast-enhanced ultrasound and histopathology (p=0.804). Chromophobe renal cell carcinoma was detected through contrast-enhanced computed tomography (n=1), but no such finding was reported by contrast-enhanced ultrasound. A total of 35 cases of papillary renal cell carcinoma were reported through contrast-enhanced ultrasound while 32 were reported through histopathology. CONCLUSIONS Contrast-enhanced ultrasound might be safe and as accurate as histopathology in diagnosing kidney lesions, especially renal cell carcinoma. Additionally, this study provides additional information over histopathology and has an excellent safety profile. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Li Jin
- Department of Ultrasound, the First People’s Hospital of Tian Shui GanSu Province, Tianshui, 741000, China
| | - Feng Xie
- Department of Ultrasound, the Second People’s Hospital of Lanzhou, Lanzhou, 730000, China
- *Corresponding author. E-mail:
| |
Collapse
|
15
|
van Loon LM, Rongen GA, van der Hoeven JG, Veltink PH, Lemson J. β-Blockade attenuates renal blood flow in experimental endotoxic shock by reducing perfusion pressure. Physiol Rep 2019; 7:e14301. [PMID: 31814327 PMCID: PMC6900489 DOI: 10.14814/phy2.14301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Clinical data suggests that heart rate (HR) control with selective β1-blockers may improve cardiac function during septic shock. However, it seems counterintuitive to start β-blocker infusion in a shock state when organ blood flow is already low or insufficient. Therefore, we studied the effects of HR control with esmolol, an ultrashort- acting β1-selective adrenoceptor antagonist, on renal blood flow (RBF) and renal autoregulation during early septic shock. In 10 healthy sheep, sepsis was induced by continuous i.v. administration of lipopolysaccharide, while maintained under anesthesia and mechanically ventilated. After successful resuscitation of the septic shock with fluids and vasoactive drugs, esmolol was infused to reduce HR with 30% and was stopped 30-min after reaching this target. Arterial and venous pressures, and RBF were recorded continuously. Renal autoregulation was evaluated by the response in RBF to renal perfusion pressure (RPP) in both the time domain and frequency domain. During septic shock, β-blockade with esmolol significantly increased the pressure dependency of RBF to RPP. Stopping esmolol showed the reversibility of the impaired renal autoregulation. Showing that clinical diligence and caution are necessary when treating septic shock with esmolol in the acute phase since esmolol reduced RPP to critical values thereby significantly reducing RBF.
Collapse
Affiliation(s)
- Lex M. van Loon
- Cardiovascular and Respiratory Physiology GroupFaculty of Science and TechnologyUniversity of TwenteEnschedeThe Netherlands
- Department of Intensive Care MedicineRadboud University Medical CenterRadboud Institute for Health SciencesNijmegenThe Netherlands
| | - Gerard A. Rongen
- Department of Pharmacology and ToxicologyRadboud University Medical CenterNijmegenThe Netherlands
| | - Johannes G. van der Hoeven
- Department of Intensive Care MedicineRadboud University Medical CenterRadboud Institute for Health SciencesNijmegenThe Netherlands
- Radboud Center for Infectious diseasesNijmegenThe Netherlands
| | - Peter H. Veltink
- Biomedical Signals and SystemsFaculty of Electrical Engineering, Mathematics and Computer ScienceTechnical Medical CentreUniversity of TwenteEnschedeThe Netherlands
| | - Joris Lemson
- Department of Intensive Care MedicineRadboud University Medical CenterRadboud Institute for Health SciencesNijmegenThe Netherlands
| |
Collapse
|
16
|
Furrer MA, Spycher SCJ, Büttiker SM, Gross T, Bosshard P, Thalmann GN, Schneider MP, Roth B. Comparison of the Diagnostic Performance of Contrast-enhanced Ultrasound with That of Contrast-enhanced Computed Tomography and Contrast-enhanced Magnetic Resonance Imaging in the Evaluation of Renal Masses: A Systematic Review and Meta-analysis. Eur Urol Oncol 2019; 3:464-473. [PMID: 31570270 DOI: 10.1016/j.euo.2019.08.013] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 08/22/2019] [Accepted: 08/30/2019] [Indexed: 01/20/2023]
Abstract
CONTEXT Contrast-enhanced ultrasound (CEUS) has the potential to be a valuable alternative to contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CEMR), the current gold standards in characterisation of renal masses. OBJECTIVE To systematically review all available evidence on the qualitative diagnostic performance of CEUS versus that of CECT and CEMR in the evaluation of benign and malignant cystic and solid renal masses. EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. EVIDENCE SYNTHESIS After screening 1483 articles, six cohort studies and 10 descriptive studies were included. Pooling data from included studies with final diagnosis of benign or malignant renal masses by pathology showed a significant difference in the sensitivity of CEUS (0.96; 95% confidence interval [CI] 0.94-0.98) versus that of CECT (0.90; 95% CI 0.86-0.93). Pooling data from included studies with final diagnosis by pathology report or reaffirmed diagnosis by follow-up imaging without pathology report showed significant difference in the sensitivity of CEUS (0.98; 95% CI 0.94-1.0) versus that of CEMR (0.78; 95% CI 0.66-0.91). CONCLUSIONS Preliminary data imply that CEUS may perform at least as well as or better than CECT and CEMR in the diagnosis of renal masses. However, the evidence base is limited, and more high-quality, well-designed, adequately powered, and sampled studies are needed to reach definitive conclusions. PATIENT SUMMARY Early data suggest that contrast-enhanced ultrasound is a promising option for the evaluation of renal masses, but more reliable evidence is required.
Collapse
Affiliation(s)
- Marc A Furrer
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland.
| | - Samuel C J Spycher
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| | - Sophia M Büttiker
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| | - Tobias Gross
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| | - Piet Bosshard
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| | - George N Thalmann
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| | - Marc P Schneider
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| | - Beat Roth
- Department of Urology, University Hospital of Bern, Inselspital, Bern, Switzerland
| |
Collapse
|
17
|
Browne JE, King D, Fagan AJ, Chari D, Moran CM. An investigation of the detection capability of pulsed wave duplex Doppler of low grade stenosis using ultrasound contrast agent microbubbles - An in-vitro study. ULTRASONICS 2019; 96:48-54. [PMID: 31004864 DOI: 10.1016/j.ultras.2019.04.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 03/11/2019] [Accepted: 04/02/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVE The objective of the study was to investigate whether clinically used ultrasonic contrast agents improved the accuracy of spectral Doppler ultrasound in the detection of low grade (<50%) renal artery stenosis. Low grade stenoses in the renal artery are notoriously difficult to reliably detect using Doppler ultrasound due to difficulties such as overlying fat and bowel gas. METHODS A range of anatomically-realistic renal artery phantoms with varying low degrees of stenosis (0, 30 and 50%) were constructed and peak velocity data was measured from within the pre-stenotic and mid-stenotic regions in each phantom, for both unenhanced and contrast-enhanced spectral Doppler data acquisitions. The effect of a 20 mm overlying fat layer on the ultrasound beam distortion and phase aberration, and hence on the measured peak velocity data, was also investigated. RESULTS The overlying fat layer produced a statistically significant underestimation (p < 0.01) in both the peak velocity and peak velocity ratio [Stenotic Region(Vmax)/Pre-stenotic Region(Vmax)] for the 0% and 30% stenosis models, but not the 50% model. A statistically significant increase (p < 0.01) in the peak velocity was found in the contrast-enhanced Doppler spectra; however, no significant difference was found between the unenhanced and contrast enhanced peak velocity ratio data, which suggests that the ratio metric has better diagnostic accuracy. The peak velocity ratios determined for each of the contrast-enhanced phantoms correctly predicted if the phantom had a stenosis and furthermore correctly classified the degree of stenosis. CONCLUSION Contrast-enhanced Doppler ultrasound could significantly assist in the early detection of renal artery disease.
Collapse
Affiliation(s)
- Jacinta E Browne
- Medical Ultrasound Physics and Technology Group, School of Physics & FOCAS, Technical University Dublin - Kevin Street Campus, Dublin 6, Ireland; Department of Radiology, Mayo Clinic, Rochester, 55901 MN, USA.
| | - Deirdre King
- Medical Physics, Blackrock Clinic, Dublin, Ireland
| | - Andrew J Fagan
- Department of Radiology, Mayo Clinic, Rochester, 55901 MN, USA
| | - Deepa Chari
- Medical Ultrasound Physics and Technology Group, School of Physics & FOCAS, Technical University Dublin - Kevin Street Campus, Dublin 6, Ireland
| | - Carmel M Moran
- Medical Physics, Centre for Cardiovascular Science, University of Edinburgh, Edinburgh EH16 4TJ, UK
| |
Collapse
|
18
|
|
19
|
van Oostenbrugge TJ, Fütterer JJ, Mulders PFA. Diagnostic Imaging for Solid Renal Tumors: A Pictorial Review. KIDNEY CANCER 2018; 2:79-93. [PMID: 30740580 PMCID: PMC6364093 DOI: 10.3233/kca-180028] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The prognosis of renal tumors depends on histologic subtype. The increased use of abdominal imaging has resulted in an increase in the number of small renal incidentaloma in recent decades. Of these incidentally discovered tumors, 20% are benign lesions warranting conservative management, but most are renal cell carcinomas that warrant a more aggressive therapeutic approach due to their malignant potential. Dedicated diagnostic renal imaging is important for characterization of renal tumors to facilitate treatment planning. This review discusses the ability to detect and differentiate renal cell carcinoma subtypes, angiomyolipoma and oncocytoma based on ultrasound imaging, computed tomography, multiparametric magnetic resonance, and nuclear imaging.
Collapse
Affiliation(s)
| | - Jurgen J Fütterer
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Peter F A Mulders
- Department of Urology, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
20
|
Mueller-Peltzer K, Negrão de Figueiredo G, Fischereder M, Habicht A, Rübenthaler J, Clevert DA. Vascular rejection in renal transplant: Diagnostic value of contrast-enhanced ultrasound (CEUS) compared to biopsy. Clin Hemorheol Microcirc 2018; 69:77-82. [PMID: 29630540 DOI: 10.3233/ch-189115] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Despite of the more potent immunosuppressive medication, vascular rejection is still a major issue after renal transplantation. Renal biopsy is the gold standard diagnostic to evaluate acute and chronic allograft rejection. As it is an invasive diagnostic there is the risk of complications like haematoma, arteriovenous fistulas, active bleeding or infection. Contrast-enhanced ultrasound is a non-invasive imaging modality that allows visualising renal transplant perfusion. OBJECTIVE To analyse the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) compared to biopsy as gold standard in diagnosing vascular rejection in renal transplant patients. METHODS A total of 57 renal transplant recipients with poor renal allograft function with initial diagnostic imaging between 2006 and 2017 were included in the study. Clinical data and imaging studies were analysed retrospectively. The diagnostic accuracy of CEUS in diagnosing vascular rejection of the renal transplant was compared to renal biopsy as gold standard. Out of 57 patients 7 patients showed signs of vascular rejection in biopsy. In 6 out of these 7 patients CEUS described irregularities in renal perfusion suspicious of vascular rejection. RESULTS CEUS showed a sensitivity of 85.7%, a specificity of 100%, a positive predictive value (PPV) of 100%, and a negative predictive value (NPV) of 98.0%. CONCLUSIONS CEUS is a safe, non-nephrotoxic imaging modality for the initial imaging of renal transplant recipients with elevated kidney function parameters suspicious of vascular rejection. Compared to renal biopsy as gold standard CEUS shows a high specificity and PPV in detecting signs of vascular rejection. Since sub-types of vascular rejection with cellular and humoral components with greater risk for allograft loss have been described renal biopsy is inevitable in these cases.
Collapse
Affiliation(s)
- K Mueller-Peltzer
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - G Negrão de Figueiredo
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - M Fischereder
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - A Habicht
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - D-A Clevert
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| |
Collapse
|
21
|
Bielskienė N, Augustinavičius V, Valančienė D, Tamošiūnas AE, Jankevičius F. Bosniak category III renal lesions: likelihood of malignancy based on computed tomography findings. Cent European J Urol 2018; 71:58-63. [PMID: 29732208 PMCID: PMC5926632 DOI: 10.5173/ceju.2017.1439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 11/26/2017] [Accepted: 12/17/2017] [Indexed: 11/22/2022] Open
Abstract
Introduction Bosniak introduced a classification of renal cysts based on imaging characteristics. Cystic renal changes are categorized determining their risk of malignancy and further management. However, defining the malignancy of category III lesions still remains a challenge and our aim was to evaluate the features of malignancy in computed tomography within this category. Material and methods The Vilnius University Hospital Santariškių Klinikos information system was retrospectively searched for computed tomography examinations in which Bosniak category III lesions were reported. Data of genetic disorders and history of malignancy were collected. Longest diameter, location, shape, amount and location of calcification, contrast enhancement of Bosniak category III lesions were evaluated. The relation between collected data and malignancy was estimated. RESULTS There were 73 patients with Bosniak category III lesions included and 43 cysts were surgically removed and histologically analyzed. Mean tumor size was significantly lower in malignant lesions. Mean enhancement in arterial and portovenous phase, change of mean enhancement in portovenous and native phases were significantly different between benign and malignant lesions. Significant differences in the contrast enhancement pattern was found: septa and capsular enhancement was detected in 28.6% (n = 12) of cases in malignant lesions, while only 4.8% (n = 2) benign lesions show the same enhancement pattern. Some other features showed tendencies to be more prevalent in malignant lesions, however, no significant differences were found. Conclusions The collected data and selected features do not allow us to reliably differentiate Bosniak category III cystic lesions as benign or malignant. Some of the criteria showed some tendencies, however, further studies are required to confirm these findings' potential.
Collapse
Affiliation(s)
- Neringa Bielskienė
- National Cancer Institute, Department of Radiology, Center for Radiology, Nuclear Medicine and Consultations, Vilnius, Lithuania
| | - Vytautas Augustinavičius
- Vilnius University, Department of Radiology, Nuclear Medicine and Physics of Medicine, Center for Radiology and Nuclear Medicine, Vilnius, Lithuania
| | - Dileta Valančienė
- Vilnius University, Department of Radiology, Nuclear Medicine and Physics of Medicine, Center for Radiology and Nuclear Medicine, Vilnius, Lithuania
| | - Algirdas Edvardas Tamošiūnas
- Vilnius University, Department of Radiology, Nuclear Medicine and Physics of Medicine, Center for Radiology and Nuclear Medicine, Vilnius, Lithuania
| | - Feliksas Jankevičius
- Vilnius University, Clinic of Gastroenterology, Nephrourology and Surgery, Center for Urology, Vilnius, Lithuania
| |
Collapse
|
22
|
Nestola M, De Matthaeis N, Ferraro PM, Fuso P, Costanzi S, Zannoni GF, Pizzolante F, Vasquez Quadra S, Gambaro G, Rapaccini GL. Contrast-enhanced ultrasonography in chronic glomerulonephritides: correlation with histological parameters of disease activity. J Ultrasound 2018; 21:81-87. [PMID: 29691759 DOI: 10.1007/s40477-018-0298-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Accepted: 02/22/2018] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To compare contrast-enhanced ultrasonography (CEUS)-derived time-intensity (TI) curves with histological findings in kidneys of patients affected by chronic glomerulonephritides (GN) in the early stage of disease. METHODS Research ethics committee approval and patient written informed consent were obtained. Thirty-one patients who showed clinical and laboratory signs of GN, with preserved renal function, were consecutively enrolled. They underwent kidney CEUS, from which TI curves were obtained, and kidney biopsy. TI curves were compared with clinical data, ultrasound (US) Doppler, and histological parameters. RESULTS The persistence of contrast agent signal during the wash-out phase was found to be correlated with the degree of disease activity (p = 0.016) and in particular with the presence of mesangial hyperplasia (p = 0.008). No correlation was observed between TI curves and clinical or Doppler US-derived parameters. CONCLUSIONS The persistence of contrast agent signal in the wash-out phase of CEUS appears to reflect a disturbance of perfusion in glomerular capillaries in the early stages of GN. We found that the histological element directly correlated with the prolonged wash-out was mesangial hyperplasia.
Collapse
Affiliation(s)
| | - Nicoletta De Matthaeis
- Gastroenterology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Pietro Manuel Ferraro
- Nephrology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Paola Fuso
- Department of Woman and Child Health, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Stefano Costanzi
- Nephrology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Gian Franco Zannoni
- Pathology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Fabrizio Pizzolante
- Gastroenterology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Sabina Vasquez Quadra
- Radiology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Giovanni Gambaro
- Nephrology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| | - Gian Ludovico Rapaccini
- Gastroenterology Unit, Policlinico A. Gemelli, Catholic University, Largo Agostino Gemelli, 8, 00168, Rome, Italy
| |
Collapse
|
23
|
O’Neal D, Cohen T, Peterson C, Barr RG. Contrast-Enhanced Ultrasound-Guided Radiofrequency Ablation of Renal Tumors. J Kidney Cancer VHL 2018; 5:7-14. [PMID: 29468107 PMCID: PMC5806030 DOI: 10.15586/jkcvhl.2018.100] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2017] [Accepted: 01/07/2018] [Indexed: 12/29/2022] Open
Abstract
Although only limited long-term studies evaluating thermal ablation of renal masses have been performed, it appears that thermal ablation has a comparable 5-year success rate to that of partial or total nephrectomy. This technique is often used in patients who are not good candidates for partial or total nephrectomy. Contrast-enhanced ultrasound (CEUS) has been recently approved by the Food and Drug Administration for characterization of focal liver lesions in adults and pediatric patients. CEUS can be used off label for renal applications and has been used for years in Europe and Asia. It has several advantages over contrast-enhanced computed tomography for use as the technique to guide and evaluate efficacy of thermal ablation of renal masses. These include the ability to visualize small amounts of enhancement, repeat dosing to evaluate efficacy of an ablation during a procedure, thin slice thickness, and real-time visualization. Ultrasound contrast is also non-nephrotoxic and non-hepatotoxic, allowing evaluation of patients with renal insufficiency. This article reviews the use of CEUS for the guidance and follow-up of thermal ablative procedures of renal masses.
Collapse
Affiliation(s)
- Dan O’Neal
- Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio, USA
| | - Tal Cohen
- Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio, USA
| | - Cynthia Peterson
- Kent State University, Salem, OH, USA
- Ultrasound Training, Southwoods Imaging, Youngstown, OH, USA
| | - Richard G. Barr
- Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio, USA
- Ultrasound Training, Southwoods Imaging, Youngstown, OH, USA
| |
Collapse
|
24
|
Kasoji SK, Rivera JN, Gessner RC, Chang SX, Dayton PA. Early Assessment of Tumor Response to Radiation Therapy using High-Resolution Quantitative Microvascular Ultrasound Imaging. Am J Cancer Res 2018; 8:156-168. [PMID: 29290799 PMCID: PMC5743466 DOI: 10.7150/thno.19703] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Accepted: 08/22/2017] [Indexed: 12/18/2022] Open
Abstract
Measuring changes in tumor volume using anatomical imaging weeks to months post radiation therapy (RT) is currently the clinical standard for indicating treatment response to RT. For patients whose tumors do not respond successfully to treatment, this approach is suboptimal as timely modification of the treatment approach may lead to better clinical outcomes. We propose to use tumor microvasculature as a biomarker for early assessment of tumor response to RT. Acoustic angiography is a novel contrast ultrasound imaging technique that enables high-resolution microvascular imaging and has been shown to detect changes in microvascular structure due to cancer growth. Data suggest that acoustic angiography can detect longitudinal changes in the tumor microvascular environment that correlate with RT response. Methods: Three cohorts of Fisher 344 rats were implanted with rat fibrosarcoma tumors and were treated with a single fraction of RT at three dose levels (15 Gy, 20 Gy, and 25 Gy) at a dose rate of 300 MU/min. A simple treatment condition was chosen for testing the feasibility of our imaging technique. All tumors were longitudinally imaged immediately prior to and after treatment and then every 3 days after treatment for a total of 30 days. Both acoustic angiography (using in-house produced microbubble contrast agents) and standard b-mode imaging was performed at each imaging time point using a pre-clinical Vevo770 scanner and a custom modified dual-frequency transducer. Results: Results show that all treated tumors in each dose group initially responded to treatment between days 3-15 as indicated by decreased tumor growth accompanied with decreased vascular density. Untreated tumors continued to increase in both volume and vascular density until they reached the maximum allowable size of 2 cm in diameter. Tumors that displayed complete control (no tumor recurrence) continued to decrease in size and vascular density, while tumors that progressed after the initial response presented an increase in tumor volume and volumetric vascular density. The increase in tumor volumetric vascular density in recurring tumors can be detected 10.25 ± 1.5 days, 6 ± 0 days, and 4 ± 1.4 days earlier than the measurable increase in tumor volume in the 15, 20, and 25 Gy dose groups, respectively. A dose-dependent growth rate for tumor recurrence was also observed. Conclusions: In this feasibility study we have demonstrated the ability of acoustic angiography to detect longitudinal changes in vascular density, which was shown to be a potential biomarker for tumor response to RT.
Collapse
|
25
|
Usawachintachit M, Tzou DT, Mongan J, Taguchi K, Weinstein S, Chi T. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System. J Endourol 2016; 31:129-134. [PMID: 27809568 DOI: 10.1089/end.2016.0693] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVES Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. PATIENTS AND METHODS From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. RESULTS Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. CONCLUSION Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.
Collapse
Affiliation(s)
- Manint Usawachintachit
- 1 Department of Urology, University of California , San Francisco, San Francisco, California.,2 Division of Urology, Faculty of Medicine, King Chulalongkorn Memorial Hospital, Chulalongkorn University , The Thai Red Cross Society, Bangkok, Thailand
| | - David T Tzou
- 1 Department of Urology, University of California , San Francisco, San Francisco, California
| | - John Mongan
- 3 Department of Radiology and Biomedical Imaging, University of California , San Francisco, San Francisco, California
| | - Kazumi Taguchi
- 1 Department of Urology, University of California , San Francisco, San Francisco, California.,4 Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences , Nagoya, Japan
| | - Stefanie Weinstein
- 3 Department of Radiology and Biomedical Imaging, University of California , San Francisco, San Francisco, California
| | - Thomas Chi
- 1 Department of Urology, University of California , San Francisco, San Francisco, California
| |
Collapse
|
26
|
Stanczak M, Lyshchik A, Shaw CM, Forsberg F, Eisenbrey JR. Contrast-Enhanced Sonography and Fusion Technology for Assessment of an Embolized Renal Angiomyolipoma. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:2292-2295. [PMID: 27672234 DOI: 10.7863/ultra.15.09070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Affiliation(s)
- Maria Stanczak
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania USA
| | - Andrej Lyshchik
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania USA
| | - Colette M Shaw
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania USA
| | - Flemming Forsberg
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania USA
| | - John R Eisenbrey
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania USA
| |
Collapse
|
27
|
Wang L, Mohan C. Contrast-enhanced ultrasound: A promising method for renal microvascular perfusion evaluation. J Transl Int Med 2016; 4:104-108. [PMID: 28191530 DOI: 10.1515/jtim-2016-0033] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
This article reviews the application of contrast-enhanced ultrasound (CEUS) in gauging renal microvascular perfusion in diverse renal diseases. The unique nature of the contrast agents used in CEUS provides real-time and quantitative imaging of the vasculature. In addition to the traditional use of CEUS for evaluation of kidney masses, it also emerges as a safe and effective imaging approach to assess microvascular perfusion in diffuse renal lesions, non-invasively. Although the precise CEUS parameters that may best predict disease still warrant systematic evaluation, animal models and limited clinical trials in humans raise hopes that CEUS could outcompete competing modalities as a first-line tool for assessing renal perfusion non-invasively, even in ailments such as acute kidney injury and chronic kidney disease.
Collapse
Affiliation(s)
- Ling Wang
- Department of Nephrology & Rheumatology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, 200072, China
| | - Chandra Mohan
- Department of Nephrology & Rheumatology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, 200072, China; Department of Biomedical Engineering, University of Houston, Houston, TX 77204, United States of America
| |
Collapse
|
28
|
Gulati M, King KG, Gill IS, Pham V, Grant E, Duddalwar VA. Contrast-enhanced ultrasound (CEUS) of cystic and solid renal lesions: a review. ACTA ACUST UNITED AC 2016; 40:1982-96. [PMID: 25588715 DOI: 10.1007/s00261-015-0348-5] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Incidentally detected renal lesions have traditionally undergone imaging characterization by contrast-enhanced computer tomography (CECT) or magnetic resonance imaging. Contrast-enhanced ultrasound (CEUS) of renal lesions is a relatively novel, but increasingly utilized, diagnostic modality. CEUS has advantages over CECT and MRI including unmatched temporal resolution due to continuous real-time imaging, lack of nephrotoxicity, and potential cost savings. CEUS has been most thoroughly evaluated in workup of complex cystic renal lesions, where it has been proposed as a replacement for CECT. Using CEUS to differentiate benign from malignant solid renal lesions has also been studied, but has proven difficult due to overlapping imaging features. Monitoring minimally invasive treatments of renal masses is an emerging application of CEUS. An additional promising area is quantitative analysis of renal masses using CEUS. This review discusses the scientific literature on renal CEUS, with an emphasis on imaging features differentiating various cystic and solid renal lesions.
Collapse
Affiliation(s)
- Mittul Gulati
- Department of Radiology, Keck USC School of Medicine, 1500 San Pablo Street, 2nd Floor Imaging, Los Angeles, CA, 90033, USA,
| | | | | | | | | | | |
Collapse
|
29
|
|
30
|
Hansen KL, Nielsen MB, Ewertsen C. Ultrasonography of the Kidney: A Pictorial Review. Diagnostics (Basel) 2015; 6:diagnostics6010002. [PMID: 26838799 PMCID: PMC4808817 DOI: 10.3390/diagnostics6010002] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Revised: 12/12/2015] [Accepted: 12/17/2015] [Indexed: 01/01/2023] Open
Abstract
Ultrasonography of the kidneys is essential in the diagnosis and management of kidney-related diseases. The kidneys are easily examined, and most pathological changes in the kidneys are distinguishable with ultrasound. In this pictorial review, the most common findings in renal ultrasound are highlighted.
Collapse
Affiliation(s)
| | - Michael Bachmann Nielsen
- Department of Radiology, Copenhagen University Hospital, Blegdamsvej 9, Copenhagen 2100-DK, Denmark.
| | - Caroline Ewertsen
- Department of Radiology, Copenhagen University Hospital, Blegdamsvej 9, Copenhagen 2100-DK, Denmark.
| |
Collapse
|
31
|
Pop CM, Mihu D, Badea R. Role of contrast-enhanced ultrasound (CEUS) in the diagnosis of endometrial pathology. ACTA ACUST UNITED AC 2015; 88:433-7. [PMID: 26733740 PMCID: PMC4689232 DOI: 10.15386/cjmed-499] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Accepted: 09/08/2015] [Indexed: 12/12/2022]
Abstract
Ultrasound is the reference imaging procedure used for the exploration of endometrial pathology. As medical procedures improve and the requirements of modern medicine become more demanding, gray-scale ultrasound is insufficient in establishing gynecological diagnosis. Thus, more complex examination techniques are required: Doppler ultrasound, contrast-enhanced ultrasound (CEUS), 3D ultrasound, etc. Contrast-enhanced ultrasound is a special examination technique that gains more and more ground. This allows a detailed real-time evaluation of microcirculation in a certain territory, which is impossible to perform by Doppler ultrasound. The aim of this review is to synthesize current knowledge regarding CEUS applications in endometrial pathology, to detail the technical aspects of endometrial CEUS and the physical properties of the equipment and contrast agents used, as well as to identify the limitations of the method.
Collapse
Affiliation(s)
- Ciprian Mihaita Pop
- 2nd Department of Obstetrics and Gynecology, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Dan Mihu
- 2nd Department of Obstetrics and Gynecology, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Radu Badea
- Ultrasound Laboratory, Department of Imaging and Radiology, Octavian Fodor Regional Institute of Gastroenterology and Hepatology and Department of Medical Imaging, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|
32
|
Paefgen V, Doleschel D, Kiessling F. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery. Front Pharmacol 2015; 6:197. [PMID: 26441654 PMCID: PMC4584939 DOI: 10.3389/fphar.2015.00197] [Citation(s) in RCA: 168] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Accepted: 08/31/2015] [Indexed: 12/21/2022] Open
Abstract
Ultrasound (US) is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents (CAs). There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular CAs enable functional analyses, e.g., to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles' shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by US pulses to locally release the entrapped agent. Recent studies show that US CAs are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of US CAs and introduces the current clinical applications of contrast-enhanced US. Additionally, an overview of the recent developments in US probe design for functional and molecular diagnosis as well as for drug delivery is given.
Collapse
Affiliation(s)
| | | | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital, AachenGermany
| |
Collapse
|
33
|
Zeisbrich M, Kihm LP, Drüschler F, Zeier M, Schwenger V. When is contrast-enhanced sonography preferable over conventional ultrasound combined with Doppler imaging in renal transplantation? Clin Kidney J 2015; 8:606-14. [PMID: 26413289 PMCID: PMC4581388 DOI: 10.1093/ckj/sfv070] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 07/10/2015] [Indexed: 12/18/2022] Open
Abstract
Conventional ultrasound in combination with colour Doppler imaging is still the standard diagnostic procedure for patients after renal transplantation. However, while conventional ultrasound in combination with Doppler imaging can diagnose renal artery stenosis and vein thrombosis, it is not possible to display subtle microvascular tissue perfusion, which is crucial for the evaluation of acute and chronic allograft dysfunctions. In contrast, real-time contrast-enhanced sonography (CES) uses gas-filled microbubbles not only to visualize but also to quantify renal blood flow and perfusion even in the small renal arterioles and capillaries. It is an easy to perform and non-invasive imaging technique that augments diagnostic capabilities in patients after renal transplantation. Specifically in the postoperative setting, CES has been shown to be superior to conventional ultrasound in combination with Doppler imaging in uncovering even subtle microvascular disturbances in the allograft perfusion. In addition, quantitative perfusion parameters derived from CES show predictive capability regarding long-term kidney function.
Collapse
Affiliation(s)
- Markus Zeisbrich
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Lars P Kihm
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Felix Drüschler
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Martin Zeier
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Vedat Schwenger
- Department of Nephrology , University Hospital , Heidelberg , Germany
| |
Collapse
|
34
|
Yang C, Hu M, Zhu T, He W. Evaluation of kidney allograft status using novel ultrasonic technologies. Asian J Urol 2015; 2:142-150. [PMID: 29264134 PMCID: PMC5730712 DOI: 10.1016/j.ajur.2015.06.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Accepted: 06/29/2015] [Indexed: 01/26/2023] Open
Abstract
Early diagnosis of kidney allograft injury contributes to proper decisions regarding treatment strategy and promotes the long-term survival of both the recipients and the allografts. Although biopsy remains the gold standard, non-invasive methods of kidney allograft evaluation are required for clinical practice. Recently, novel ultrasonic technologies have been applied in the evaluation and diagnosis of kidney allograft status, including tissue elasticity quantification using acoustic radiation force impulse (ARFI) and contrast-enhanced ultrasonography (CEUS). In this review, we discuss current opinions on the application of ARFI and CEUS for evaluating kidney allograft function and their possible influencing factors, advantages and limitations. We also compare these two technologies with other non-invasive diagnostic methods, including nuclear medicine and radiology. While the role of novel non-invasive ultrasonic technologies in the assessment of kidney allografts requires further investigation, the use of such technologies remains highly promising.
Collapse
Affiliation(s)
- Cheng Yang
- Department of Urology, Zhongshan Hospital, Fudan University, Shanghai Key Laboratory of Organ Transplantation, Shanghai, China
| | - Mushuang Hu
- Department of Urology, Zhongshan Hospital, Fudan University, Shanghai Key Laboratory of Organ Transplantation, Shanghai, China
| | - Tongyu Zhu
- Department of Urology, Zhongshan Hospital, Fudan University, Shanghai Key Laboratory of Organ Transplantation, Shanghai, China
| | - Wanyuan He
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai Institute of Imaging Medicine, Shanghai, China
| |
Collapse
|
35
|
Allard CB, Coret A, Dason S, Tajzler C, Shayegan B, Matsumoto ED, Kapoor A. Contrast-enhanced Ultrasonography for Surveillance of Radiofrequency-ablated Renal Tumors: A Prospective, Radiologist-blinded Pilot Study. Urology 2015; 86:1174-8. [PMID: 26123518 DOI: 10.1016/j.urology.2015.04.062] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 04/03/2015] [Accepted: 04/25/2015] [Indexed: 01/16/2023]
Abstract
OBJECTIVE To prospectively evaluate the performance of contrast-enhanced ultrasonography (CEUS) for surveillance after radiofrequency ablation (RFA) of small renal masses by comparing CEUS to the contrast-enhanced computed tomography (CECT), the current gold standard. PATIENTS AND METHODS Patients underwent surveillance after RFA of small renal masses (≤4 cm) consisting of CECT scans at 3 and 6 months and every 6 months thereafter. Participants additionally underwent ≥1 CEUS within 90 days before CECT. Percutaneous biopsy was performed for lesions suspicious for recurrence on CECT. Independent, blinded radiologists interpreted CEUS and CECT scans. Intermodality agreement was evaluated with the kappa coefficient. RESULTS In total, 37 pairs of CEUS and CECT scans were performed. Median tumor size was 2.5 cm (range, 1.4-4.0 cm). Median follow-up from RFA to CEUS was 25 months. Renal tumor recurrences were diagnosed by CECT in 3 patients and confirmed histopathologically by percutaneous biopsy; 34 CECT scans were negative for recurrence. The diagnostic rate of CEUS was 94.6%; 2 CEUS scans were nondiagnostic because of patient body habitus. Among diagnostic CEUS scans, tumor enhancement was present in 3 and absent in 32. We observed perfect concordance between CEUS and CECT (=1.0; P <.0001). CONCLUSION This is the first prospective study incorporating radiologist blinding to evaluate CEUS for RFA surveillance. Our findings suggest CEUS may ultimately be incorporated into RFA surveillance protocols. The operator dependency of CEUS is a possible barrier to its widespread adoption. These findings justify larger studies with longer follow-up.
Collapse
Affiliation(s)
- Christopher B Allard
- Division of Urology, Massachusetts General Hospital & Brigham and Women's Hospital, Boston, MA
| | - Alexander Coret
- Department of Radiology, St. Joseph's Healthcare, Hamilton, Ontario, Canada
| | - Shawn Dason
- Department of Urology, McMaster University, Hamilton, Ontario, Canada
| | - Camilla Tajzler
- Department of Urology, McMaster University, Hamilton, Ontario, Canada
| | - Bobby Shayegan
- Department of Urology, McMaster University, Hamilton, Ontario, Canada
| | | | - Anil Kapoor
- Department of Urology, McMaster University, Hamilton, Ontario, Canada.
| |
Collapse
|
36
|
Malhi H, Grant EG, Duddalwar V. Contrast-enhanced ultrasound of the liver and kidney. Radiol Clin North Am 2014; 52:1177-90. [PMID: 25444099 DOI: 10.1016/j.rcl.2014.07.005] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The clinical use of noncardiac contrast-enhanced ultrasound scan (CEUS) has been steadily gaining momentum. CEUS is a reliable and safe technique with a diverse array of applications. This article reviews the current and potential future clinical applications of CEUS. Emphasis will be placed on evaluating focal lesions with the liver and kidney. Contrast agent composition and mechanism are also briefly reviewed.
Collapse
Affiliation(s)
- Harshawn Malhi
- Department of Radiology, Keck Hospital of USC, University of Southern California, 1500 San Pablo Street, Los Angeles, CA 90033, USA.
| | - Edward G Grant
- Department of Radiology, Keck Hospital of USC, USC Norris Comprehensive Cancer Center, University of Southern California, 1500 San Pablo Street, Los Angeles, CA 90033, USA
| | - Vinay Duddalwar
- Abdominal Imaging, Imaging, Keck Hospital of USC, USC Norris Comprehensive Cancer Center, University of Southern California, 1500 San Pablo Street, Los Angeles, CA 90033, USA
| |
Collapse
|