1
|
Yadav K, Bhardwaj A, Sunder Raman R. Chemical characterization, source identification and potential health effects of PM 2.5-bound non-polar organic compounds over a COALESCE network site - Bhopal, India. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 920:170957. [PMID: 38365037 DOI: 10.1016/j.scitotenv.2024.170957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 02/09/2024] [Accepted: 02/11/2024] [Indexed: 02/18/2024]
Abstract
Year-long (2019) measurements of carbonaceous aerosols were performed at Bhopal, a regionally representative site as a part of the COALESCE (Carbonaceous Aerosol Emissions, Source apportionment and Climate Impacts) campaign. Aerosol-associated non-polar organic compounds (NPOCs) were analysed using thermal desorption (TD) Gas chromatography/Mass spectrometry (TD-GC/MS). The annual average of the total organic carbon (OC), elemental carbon (EC), and analysed PAHs (Polycyclic Aromatic Hydrocarbons), and n-alkanes were, 9.74 ± 9.47 μg m-3, 2.13 ± 3.12 μg m-3, 10.43 ± 5.49 ng m-3, and 114.93 ± 49.24 ng m-3, respectively. PAHs diagnostic ratios suggested emissions from petroleum, grass, wood, and coal combustion. Combustion derived PAHs (CombPAHs) accounted for 72.5 % of the total measured PAHs. During wintertime, based on Pyr/BaP ratio (∼0.6), gasoline exhaust emissions were higher compared to diesel exhaust emissions. The weak correlations between PAHs and meteorological parameters suggested that variations in PAH levels are primarily driven by alterations in emission sources. Total PAHs were correlated moderately with BrC (r2 = 0.60). The estimated lifetime lung cancer risk (LLCR) values on exposure to 16 USEPA priority PAHs (5 × 10-5) demonstrated that PAH levels in this region pose moderate health risks. Given observations from only campaign mode short-term measurements of NPOCs over India, this work provides a more comprehensive understanding of the concentrations, seasonal variations, and sources of n-alkanes and health risk associated with particle bound PAHs over the data-poor central Indian region.
Collapse
Affiliation(s)
- Kajal Yadav
- Department of Earth and Environmental Sciences, Indian Institute of Science Education and Research Bhopal, Bhopal by-pass road, Bhauri, Bhopal 462066, Madhya Pradesh, India
| | - Ankur Bhardwaj
- Department of Earth and Environmental Sciences, Indian Institute of Science Education and Research Bhopal, Bhopal by-pass road, Bhauri, Bhopal 462066, Madhya Pradesh, India
| | - Ramya Sunder Raman
- Department of Earth and Environmental Sciences, Indian Institute of Science Education and Research Bhopal, Bhopal by-pass road, Bhauri, Bhopal 462066, Madhya Pradesh, India.
| |
Collapse
|
2
|
V González-de-Peredo A, Vázquez-Espinosa M, Espada-Bellido E, Ferreiro-González M, Carrera C, Palma M, F Barbero G. Application of Direct Thermal Desorption-Gas Chromatography-Mass Spectrometry for Determination of Volatile and Semi-Volatile Organosulfur Compounds in Onions: A Novel Analytical Approach. Pharmaceuticals (Basel) 2023; 16:ph16050715. [PMID: 37242498 DOI: 10.3390/ph16050715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/27/2023] [Accepted: 05/02/2023] [Indexed: 05/28/2023] Open
Abstract
The population is now more aware of their diets due to the connection between food and general health. Onions (Allium cepa L.), common vegetables that are minimally processed and grown locally, are known for their health-promoting properties. The organosulfur compounds present in onions have powerful antioxidant properties and may decrease the likelihood of developing certain disorders. It is vital to employ an optimum approach with the best qualities for studying the target compounds to undertake a thorough analysis of these compounds. In this study, the use of a direct thermal desorption-gas chromatography-mass spectrometry method with a Box-Behnken design and multi-response optimization is proposed. Direct thermal desorption is an environmentally friendly technique that eliminates the use of solvents and requires no prior preparation of the sample. To the author's knowledge, this methodology has not been previously used to study the organosulfur compounds in onions. Likewise, the optimal conditions for pre-extraction and post-analysis of organosulfur compounds were as follows: 46 mg of onion in the tube, a desorption heat of 205 °C for 960 s, and a trap heat of 267 °C for 180 s. The repeatability and intermediate precision of the method were evaluated by conducting 27 tests over three consecutive days. The results obtained for all compounds studied revealed CV values ranging from 1.8% to 9.9%. The major compound reported in onions was 2,4-dimethyl-thiophene, representing 19.4% of the total area of sulfur compounds. The propanethial S-oxide, the principal compound responsible for the tear factor, accounted for 4.5% of the total area.
Collapse
Affiliation(s)
- Ana V González-de-Peredo
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| | - Mercedes Vázquez-Espinosa
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| | - Estrella Espada-Bellido
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| | - Marta Ferreiro-González
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| | - Ceferino Carrera
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| | - Miguel Palma
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| | - Gerardo F Barbero
- Department of Analytical Chemistry, Faculty of Sciences, Wine and Agrifood Research Institute (IVAGRO), University of Cadiz, Agrifood Campus of International Excellence (ceiA3), 11510 Puerto Real, Spain
| |
Collapse
|
3
|
Humbert K, Debret M, Morin C, Cosme J, Portet-Koltalo F. Direct thermal desorption-gas chromatography-tandem mass spectrometry versus microwave assisted extraction and GC-MS for the simultaneous analysis of polyaromatic hydrocarbons (PAHs, PCBs) from sediments. Talanta 2022; 250:123735. [PMID: 35839607 DOI: 10.1016/j.talanta.2022.123735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 07/06/2022] [Accepted: 07/08/2022] [Indexed: 11/27/2022]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) are regulated contaminants usually investigated in sediments. Conventional approaches often use GC-MS to analyse them with a preliminary extraction step which can be solvent- and time-consuming. Here two extraction methodologies were optimized using experimental designs, and compared: microwave assisted extraction (MAE) and thermal desorption (TD); the latter was rarely used for sediments analyses. Several factors that may influence extraction recoveries were studied including matrix parameters (mass, organic matter (OM) content) and processing parameters. A definitive screening design DSD was performed to screen the 6 most influencing factors and model the extraction recoveries using TD. Whatever the OM content, a minimum sediment mass (5 mg) was better for an optimal extraction, with a minimum temperature rate (15 °C min-1), a maximum final temperature (350 °C) associated with a minimum hold time (5 min), and a maximum vent flow (150 mL min-1) between the TD unit and the cryogenic trap. Thereafter matrix effects were evaluated using standard addition, and quality assurance and control were implemented for comparing MAE and TD. TD-GC-MS/MS sensitivity was higher than MAE-GC-MS with detection limits in the range 5-1160 pg and 20-125 pg for PAHs and PCBs, respectively. When considering the appropriate strategy for quantification, TD was also reliable for sediments analysis. Although MAE was less sensitive to matrix effects, TD could significantly improve the analytical process, due to direct coupling with GC-MS/MS and complete automation. Moreover, TD offered possible higher spatial resolution than MAE, particularly for sediment cores analysis, due to the 1000-times lower sample size. At last, TD-GC-MS/MS appeared as a greener analytical procedure.
Collapse
Affiliation(s)
- Kévin Humbert
- Normandie University, UNIROUEN, COBRA Laboratory UMR CNRS 6014, 55 rue Saint Germain, 27000, Evreux, France; Normandie University, UNIROUEN, M2C Laboratory UMR 6143, FR CNRS 3730 SCALE, Bâtiment Blondel, Place Emile Blondel, 76821, Mont Saint Aignan Cedex, France.
| | - Maxime Debret
- Normandie University, UNIROUEN, M2C Laboratory UMR 6143, FR CNRS 3730 SCALE, Bâtiment Blondel, Place Emile Blondel, 76821, Mont Saint Aignan Cedex, France.
| | - Christophe Morin
- Normandie University, UNIROUEN, COBRA Laboratory UMR CNRS 6014, 55 rue Saint Germain, 27000, Evreux, France.
| | - Julie Cosme
- Normandie University, UNIROUEN, COBRA Laboratory UMR CNRS 6014, 55 rue Saint Germain, 27000, Evreux, France.
| | - Florence Portet-Koltalo
- Normandie University, UNIROUEN, COBRA Laboratory UMR CNRS 6014, 55 rue Saint Germain, 27000, Evreux, France.
| |
Collapse
|
4
|
Chu X, Aono A, Tanaka K, Miyake Y, Fuse Y. Thermal Extraction of Polycyclic Aromatic Hydrocarbons from Atmospheric 2.5 μm Particulate Matter Collected on a Filter Paper Using a High-Temperature Headspace Method. ANAL SCI 2021; 37:1727-1733. [PMID: 34148923 DOI: 10.2116/analsci.21p126] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Recently, owing to the performance improvement of the headspace (HS)-sampling devices and its consumables, HS vial samples can be analyzed at temperatures up to 300°C. Some studies have attempted to analyze polycyclic aromatic hydrocarbons (PAHs) in atmospheric 2.5 μm particulate matter (PM 2.5) collected on a filter paper by gas chromatography/mass spectrometry (GC/MS) coupled with thermal desorption device. However, no studies have reported the use of an HS-sampling device to quantify PAHs in PM 2.5 filter paper. In this study, we found that the quantification of PAH analysis using HS-GC/MS can be improved by the following steps, so that the accuracy becomes almost the same as that of a solvent-extraction method: 1) replacement of the air in the HS vial with nitrogen, 2) limiting the solvent to toluene, 3) using the hydrolyzed polyimide-covered septum, and 4) optimization of the heating temperature and heating time of the HS vial. As a result, we succeeded in protecting PAHs in an HS vial at a high temperature and in creating an analysis method with a high recovery rate and high repeatability; the limit of quantitation of each PAH in this method was 5.4 pg m-3 in the case of a volume of 10080 m3 of air being collected on the filter paper.
Collapse
Affiliation(s)
- Xue Chu
- Graduate School of Science and Technology, Kyoto Institute of Technology.,Shimadzu Corporation
| | | | | | - Yusuke Miyake
- Graduate School of Science and Technology, Kyoto Institute of Technology
| | - Yasuro Fuse
- Graduate School of Science and Technology, Kyoto Institute of Technology
| |
Collapse
|
5
|
Ueta I, Takenaka R, Fujimura K, Yoshimura T, Narukami S, Mochizuki S, Maeda T. Simultaneous Extraction and Determination of Volatile Organic Compounds and Semi-volatile Organic Compounds in Indoor Air Using Multi-bed Solid Phase Extraction Device. ANAL SCI 2020; 36:1071-1074. [PMID: 32307348 DOI: 10.2116/analsci.20p022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A method for the simultaneous extraction and determination of indoor volatile compounds, including volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs), was developed using a multi-bed solid phase extraction (SPE)-type collection device. The collection device was prepared by packing styrene-divinylbenzene polymer particles and activated carbon particles. The collected analytes were completely desorbed by passing 7 mL of acetone, and the solvent was then injected into a gas chromatograph-mass spectrometry without the concentration process. Because the proposed method does not require ultrasonication and a concentration process of eluted solvent, quantitative determination of a relatively volatile compound could be achieved. The total recovery including extraction and elution recoveries for all the investigated analytes were in the range from 91.6 to 109%. The limit of quantification was less than 4.0 ng L-1 for all the investigated analytes, and relative standard deviations of the peak area of the analytes in indoor air were less than 12%. The collection device could be reused for over 50 samplings.
Collapse
Affiliation(s)
- Ikuo Ueta
- Department of Applied Chemistry, University of Yamanashi
| | - Risa Takenaka
- Department of Applied Chemistry, University of Yamanashi
| | | | | | | | | | - Tsuneaki Maeda
- Professionals' Network in Advanced Instrumentation Society
| |
Collapse
|
6
|
Walker HJ, Burrell MM. Could breath analysis by MS could be a solution to rapid, non-invasive testing for COVID-19? Bioanalysis 2020; 12:1213-1217. [PMID: 32734782 PMCID: PMC7466950 DOI: 10.4155/bio-2020-0125] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 06/11/2020] [Indexed: 01/13/2023] Open
Affiliation(s)
- Heather J Walker
- biOMICS Facility, Department of Animal & Plant Sciences, University of Sheffield, Sheffield S10 2TN, UK
| | - Michael M Burrell
- biOMICS Facility, Department of Animal & Plant Sciences, University of Sheffield, Sheffield S10 2TN, UK
| |
Collapse
|
7
|
Mercier F, Gilles E, Soulard P, Mandin C, Dassonville C, Le Bot B. On-line coupling of thermal extraction with gas chromatography / tandem mass spectrometry for the analysis of semivolatile organic compounds in a few milligrams of indoor dust. J Chromatogr A 2020; 1615:460768. [DOI: 10.1016/j.chroma.2019.460768] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 12/02/2019] [Accepted: 12/03/2019] [Indexed: 01/29/2023]
|
8
|
Liu H, Ma S, Zhang X, Yu Y. Application of thermal desorption methods for airborne polycyclic aromatic hydrocarbon measurement: A critical review. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 254:113018. [PMID: 31419659 DOI: 10.1016/j.envpol.2019.113018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 08/01/2019] [Accepted: 08/03/2019] [Indexed: 06/10/2023]
Abstract
Thermal desorption (TD) is a universal solvent-free pre-concentration technique. It is often used to pre-concentrate semi-volatile and volatile organic compounds in various sample types. Polycyclic aromatic hydrocarbons (PAHs) are widespread contaminants from incomplete combustion of organic matter and fossil fuel, which have carcinogenic effects on human health. Conventional methods for determining PAHs, represented by solvent extraction, are gradually being replaced by solvent-free methods, typically the TD technique, because of TD's many advantages, including time savings and environmentally friendly treatment. This work presents an extensive review of the universal methods used to determine PAHs in the atmosphere based on the TD technique. The methods currently used for collection and detection of both gas- and particle-phase PAHs in the air are critically reviewed. In addition, the operating parameters of the TD unit are summarized and discussed. The design shortcomings of existing studies and the problems that researchers should address are presented, and promising alternatives are suggested. This paper also discusses important parameters, such as reproducibility and limit of detection, that form a crucial part of quality assurance. Finally, the limitations and the future prospects of the TD technique for use in airborne PAH analyses are addressed. This is the first review of the latest developments of the TD technique for analysis of PAHs and their derivatives in the atmosphere.
Collapse
Affiliation(s)
- Hao Liu
- School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444, China; Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| | - Shengtao Ma
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China; Synergy Innovation Institute of GDUT, Shantou 515100, China
| | - Xiaolan Zhang
- School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444, China
| | - Yingxin Yu
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.
| |
Collapse
|
9
|
Determination of atmospheric particle-bound polycyclic aromatic hydrocarbons using subcritical water extraction coupled with membrane microextraction. J Chromatogr A 2019; 1606:460381. [DOI: 10.1016/j.chroma.2019.460381] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 07/15/2019] [Accepted: 07/17/2019] [Indexed: 11/24/2022]
|
10
|
Wallace MAG, Pleil JD, Whitaker DA, Oliver KD. Recovery and reactivity of polycyclic aromatic hydrocarbons collected on selected sorbent tubes and analyzed by thermal desorption-gas chromatography/mass spectrometry. J Chromatogr A 2019; 1602:19-29. [PMID: 31128883 DOI: 10.1016/j.chroma.2019.05.030] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/13/2019] [Accepted: 05/14/2019] [Indexed: 12/13/2022]
Abstract
This article describes the optimization of methodology for extending the measurement of volatile organic compounds (VOCs) to increasingly heavier polycyclic aromatic hydrocarbons (PAHs) with a detailed focus on recent sorbent tube technology. Although PAHs have lower volatility than compounds such as benzene, toluene, ethylbenzene and xylenes, these semi-volatile compounds can be detected in air and breath samples. For this work, PAHs were captured on sorbent tubes and subsequently analyzed using automated thermal desorption gas chromatography - mass spectrometry (ATD-GC/MS). While many different sorbent tubes are commercially available, optimization for airborne PAH sampling using sorbent tubes has not been previously considered. Herein, several commercially available sorbent tubes, including Carbograph 2 TD/1TD, Tenax TA, XRO-440, and inert-coated PAH tubes are compared to determine the relative recovery for eight PAHs commonly found in the environment. Certain types of sorbent materials were found to be better suited for PAH recovery during thermal desorption, and PAH reaction products were observed on several types of sorbent tubes, including graphitized carbon black sorbents with stainless steel tube materials. As such, selection of sorbent tube media should be carefully considered prior to embarking on a PAH study.
Collapse
Affiliation(s)
- M Ariel Geer Wallace
- National Exposure Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27709, USA.
| | - Joachim D Pleil
- National Exposure Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27709, USA.
| | - Donald A Whitaker
- National Exposure Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27709, USA.
| | - Karen D Oliver
- National Exposure Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27709, USA.
| |
Collapse
|
11
|
UETA I, TAKENAKA R, FUJIMURA K, NARUKAMI S, SASAKI T, MAEDA T. Quantitative Determination of 2-Ethyl-1-hexanol, Texanol and TXIB in In-door Air Using a Solid-Phase Extraction-type Collection Device Followed by Gas Chromatography–Mass Spectrometry. ANAL SCI 2019; 35:855-859. [DOI: 10.2116/analsci.19p033] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Ikuo UETA
- Department of Applied Chemistry, University of Yamanashi
| | - Risa TAKENAKA
- Department of Applied Chemistry, University of Yamanashi
| | | | | | | | - Tsuneaki MAEDA
- Professionals’ Network in Advanced Instrumentation Society
| |
Collapse
|
12
|
Yuan X, You F, Yong L, Yang C, Zhu L, Hu B, Liu T. Rapid determination of 16 polycyclic aromatic hydrocarbons in PM2.5 by microwave assisted extraction-high performance liquid chromatography. Microchem J 2019. [DOI: 10.1016/j.microc.2018.09.029] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|