1
|
Hu H, Zhao Y, He C, Qian L, Huang P. Ultrasonography of Hepatocellular Carcinoma: From Diagnosis to Prognosis. J Clin Transl Hepatol 2024; 12:516-524. [PMID: 38779517 PMCID: PMC11106354 DOI: 10.14218/jcth.2024.00018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 03/15/2024] [Accepted: 04/07/2024] [Indexed: 05/25/2024] Open
Abstract
Hepatocellular carcinoma (HCC) is a prominent contributor to cancer-related mortality worldwide. Early detection and diagnosis of liver cancer can significantly improve its prognosis and patient survival. Ultrasound technology, serving has undergone substantial advances as the primary method of HCC surveillance and has broadened its scope in recent years for effective management of HCC. This article is a comprehensive overview of ultrasound technology in the treatment of HCC, encompassing early detection, diagnosis, staging, treatment evaluation, and prognostic assessment. In addition, the authors summarized the application of contrast-enhanced ultrasound in the diagnosis of HCC and assessment of prognosis. Finally, the authors discussed further directions in this field by emphasizing overcoming existing obstacles and integrating cutting-edge technologies.
Collapse
Affiliation(s)
- Huisen Hu
- Department of Ultrasound, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Department of Ultrasound, Lanxi People’s Hospital, Lanxi, Zhejiang, China
| | - Yonglei Zhao
- Department of Radiology, Sir Run Run Shaw Hospital (SRRSH), Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Chengbin He
- Department of Radiology, Sir Run Run Shaw Hospital (SRRSH), Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Lujie Qian
- The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Pintong Huang
- Department of Ultrasound, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| |
Collapse
|
2
|
Han S, Lee MW, Lee YJ, Hong HP, Lee DH, Lee JM. No-Touch Radiofrequency Ablation for Early Hepatocellular Carcinoma: 2023 Korean Society of Image-Guided Tumor Ablation Guidelines. Korean J Radiol 2023; 24:719-728. [PMID: 37500573 PMCID: PMC10400366 DOI: 10.3348/kjr.2023.0423] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Accepted: 05/09/2023] [Indexed: 07/29/2023] Open
Abstract
Radiofrequency ablation (RFA) has been widely used to manage hepatocellular carcinomas (HCCs) equal to or smaller than 3 cm. No-touch RFA has gained attention and has recently been implemented in local ablation therapy for HCCs, despite its technical complexity, as it provides improved local tumor control compared to conventional tumor-puncturing RFA. This article presents the practice guidelines for performing no-touch RFA for HCCs, which have been endorsed by the Korean Society of Image-Guided Tumor Ablation (KSITA). The guidelines are primarily designed to assist interventional oncologists and address the limitations of conventional tumor-puncturing RFA with describing the fundamental principles, various energy delivery methods, and clinical outcomes of no-touch RFA. The clinical outcomes include technical feasibility, local tumor progression rates, survival outcomes, and potential complications.
Collapse
Affiliation(s)
- Seungchul Han
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Min Woo Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul, Korea
| | - Young Joon Lee
- Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Hyun Pyo Hong
- Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Dong Ho Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
| |
Collapse
|
3
|
Zakaria UMU, Mustaza SM, Zaman MHM, Rahni AAA. Development of Real-Time Contact Force Control of a Collaborative Robot for Automated Ultrasound Scanning. 2022 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES) 2022. [DOI: 10.1109/iecbes54088.2022.10079599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Affiliation(s)
- Ungku M.Z. Ungku Zakaria
- Universiti Kebangsaan Malaysia,Faculty of Engineering & Built Environment,Bangi,Selangor,Malaysia,43600
| | - Seri M. Mustaza
- Universiti Kebangsaan Malaysia,Faculty of Engineering & Built Environment,Bangi,Selangor,Malaysia,43600
| | - Mohd H. Mohd Zaman
- Universiti Kebangsaan Malaysia,Faculty of Engineering & Built Environment,Bangi,Selangor,Malaysia,43600
| | - Ashrani A. Abd. Rahni
- Universiti Kebangsaan Malaysia,Faculty of Engineering & Built Environment,Bangi,Selangor,Malaysia,43600
| |
Collapse
|
4
|
Mitani H, Naito A, Chosa K, Kodama H, Sumida M, Moriya T, Awai K. Safety margin for CT- and US-guided radiofrequency ablation after TACE of HCC in the hepatic dome. MINIM INVASIV THER 2021; 31:894-901. [PMID: 34726557 DOI: 10.1080/13645706.2021.1995436] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
INTRODUCTION We evaluated the safety margin in patients with hepatocellular carcinoma (HCC) in the hepatic dome who underwent computed tomography (CT)- or ultrasound (US)-guided radiofrequency ablation (RFA). MATERIAL AND METHODS Included in this single-center study were 46 patients with 56 HCCs in the hepatic dome undergoing RFA after transarterial chemoembolization from January 2009 to December 2016. Thirty were addressed with CT fluoroscopy and 26 with US guidance. The technical success, safety margin, and local tumor progression (LTP) were evaluated. RESULTS Technical success rate was 100% in the CT-RFA and 84.6% in the US-RFA group (p = .04). The average safety margin was 4.8 mm in the CT-RFA and 3.0 mm in the US-RFA group (p = .01). There was no LTP among the HCCs with a safety margin >3 mm achieved in 73.3% CT-RFA and 42.3% US-RFA group tumors (p = .03). Of the US-RFA group, six required additional RFA. There was no significant inter-group difference in LTP (p = .36). CONCLUSION CT-guided RFA was superior to US-guided RFA with respect to the technical success rate and the acquisition of an appropriate safety margin in patients with HCC in the hepatic dome.
Collapse
Affiliation(s)
- Hidenori Mitani
- Department of Radiology, Chugoku Rosai Hospital, Kure, Japan.,Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University Hospital, Hiroshima, Japan
| | - Akira Naito
- Department of Radiology, Memorial Jun Makidono Hospital, Hiroshima, Japan
| | - Keigo Chosa
- Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University Hospital, Hiroshima, Japan
| | - Hisayuki Kodama
- Department of Radiology, Chugoku Rosai Hospital, Kure, Japan
| | - Masumi Sumida
- Department of Radiology, Chugoku Rosai Hospital, Kure, Japan
| | - Takashi Moriya
- Department of Internal Medicine, Chugoku Rosai Hospital, Kure, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University Hospital, Hiroshima, Japan
| |
Collapse
|
5
|
Gennaro N, Schiaffino S, Mauri G, Monfardini L. The What, the Why, and the How of Liver Ablations: A Practical Guide for the Medical Oncologist. Oncology 2021; 99:722-731. [PMID: 34515198 DOI: 10.1159/000518358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Accepted: 06/25/2021] [Indexed: 11/19/2022]
Abstract
Interventional oncology plays a major role within modern oncological patient management. Image-guided thermal ablation has been recognized as a successful local therapeutic option in patients with primary and secondary malignant liver diseases, as also recalled by the recent European Society of Medical Oncology (ESMO) guidelines on colorectal metastases. As image-guided treatments may be as effective as surgery in selected patients with liver lesions, the clinical oncologist should be familiar with the indications, risks, and technical aspects of liver ablation in order to provide their patients with the best outcomes. This article provides a broad overview of the most commonly used ablation techniques and highlights the most relevant technical aspects such as the ideal setting in the operating theatre; which image-guided methods are available, including the growing application of fusion imaging; or contrast-enhanced ultrasound for guiding/monitoring the procedure. A further aim is to expand the knowledge among medical oncologists about liver ablation procedures and to provide insights into the future perspectives of percutaneous minimally invasive procedures in the liver.
Collapse
Affiliation(s)
- Nicolò Gennaro
- Istituto di Imaging della Svizzera Italiana (IIMSI), Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland
| | - Simone Schiaffino
- Radiology Unit IRCCS Policlinico San Donato, Piazza Edmondo Malan 2, San Donato Milanese, Italy
| | - Giovanni Mauri
- Divisione di Radiologia Interventistica, Istituto Europeo di Oncologia, IRCCS, Milan, Italy.,Dipartimento di Oncologia ed Emato-Oncologia, Università degli Studi di Milano, Milan, Italy
| | | |
Collapse
|
6
|
Bae JW, Lee MW, Kang TW, Song KD, Cha DI, Min JH, Rhim H. Percutaneous radiofrequency ablation for hepatic metastasis of colorectal cancer: assessment of tumor visibility and the feasibility of the procedure with planning ultrasonography. Ultrasonography 2021; 41:189-197. [PMID: 34492754 PMCID: PMC8696149 DOI: 10.14366/usg.21050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 06/22/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study was to assess the incidence and causes of percutaneous radiofrequency ablation (RFA) infeasibility in cases of metastatic colorectal cancer and to evaluate factors affecting the invisibility of the tumor on planning ultrasonography (US). Methods This study screened 386 patients who underwent planning US using fusion imaging and/or contrast-enhanced US for percutaneous RFA for suspected metastatic colorectal cancer between January 2013 and December 2020, from whom 136 patients with a single hepatic metastasis from colorectal cancer measuring <3 cm were included. The factors related to the infeasibility of percutaneous RFA were investigated. Univariate and multivariate analyses were performed to assess the factors associated with tumor invisibility on planning US. Results Among the 136 patients, percutaneous RFA was considered infeasible in 24.3% (33/136) due to a high risk of the heat-sink effect caused by the abutment of a large vessel (n=12), an inconspicuous tumor on planning US (n=11), a high risk of collateral thermal damage to an adjacent organ (n=8), and the absence of a safe electrode path (n=2). In univariate and multivariate analyses, tumor size was a statistically significant factor affecting invisibility on planning US (P=0.003 and P=0.018, respectively). Conclusion Percutaneous RFA was infeasible in approximately one-fourth of patients with metastatic colorectal cancer. The reason for the infeasibility was mainly an unfavorable tumor location and invisibility on planning US. Small tumor size was the sole significant factor affecting the invisibility of hepatic metastases on planning US.
Collapse
Affiliation(s)
- Jeong Woo Bae
- Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Min Woo Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| | - Tae Wook Kang
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| | - Kyoung Doo Song
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| | - Dong Ik Cha
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Ji Hye Min
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyunchul Rhim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| |
Collapse
|
7
|
Tokunaga K, Furuta A, Iizuka Y, Isoda H, Togashi K. Utility of real-time image fusion technology in ultrasonography-guided fiducial marker implantation for stereotactic body radiation therapy for liver tumors. Acta Radiol 2021; 62:567-573. [PMID: 32586122 DOI: 10.1177/0284185120934479] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Ultrasonography (US) is useful when implanting fiducial markers in the liver. However, the implant position is sometimes lost. Recently, real-time image fusion technology (Volume Navigation [V-navi]; GE Healthcare, Milwaukee, WI, USA) has been introduced as a technique for using images from different modalities, and its utility for fiducial marker implantation has been hypothesized. PURPOSE To evaluate the utility of US-guided fiducial marker implantation in the liver using V-navi compared to conventional US. MATERIAL AND METHODS We retrospectively reviewed 35 patients who underwent fiducial marker implantation for stereotactic body radiation therapy of liver tumors in 2013-2018. To avoid artifacts obscuring the tumor, the target point of implantation was set 10 mm cranial or caudal to the tumor. Marker implantation was then performed using US alone (US group, n = 24) or V-navi with computed tomography (CT) or magnetic resonance imaging (V-navi group, n = 11). Postprocedural CT was evaluated to determine technical success, distances between marker and either tumor surface or target point, and whether marker-induced artifacts obscured the tumor. Complications were also evaluated. Results were compared between groups. RESULTS Technical success was obtained in 33 patients. Distance between the tumor and marker showed no significant difference between groups. Distance between target point and marker was shorter in the V-navi group (P = 0.0093). Tumor-obscuring artifacts were seen in 12 patients (V-navi group, n = 1; US group, n = 11; P = 0.055). The only complication was minor bleeding in the US group (n = 1). CONCLUSION V-navi appears useful for US-guided fiducial marker implantation in the liver compared with conventional US.
Collapse
Affiliation(s)
- Koji Tokunaga
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Akihiro Furuta
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Yusuke Iizuka
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Hiroyoshi Isoda
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Kaori Togashi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| |
Collapse
|
8
|
Xu E, Li K, Long Y, Luo L, Zeng Q, Tan L, He X, Huang Q, Wu Y, Zheng R. Intra-Procedural CT/MR-Ultrasound Fusion Imaging Helps to Improve Outcomes of Thermal Ablation for Hepatocellular Carcinoma: Results in 502 Nodules. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2021; 42:e9-e19. [PMID: 31671457 DOI: 10.1055/a-1021-1616] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
PURPOSE The aim was to assess the value of intra-procedural CT/MR-ultrasound (CT/MR-US) fusion imaging in the management of thermal ablation for hepatocellular carcinoma (HCC). MATERIALS AND METHODS This retrospective study was approved by the institutional review board. From May 2010 to October 2016, 543 HCC nodules in 440 patients (387 men and 53 women; age range: 25-84 years) that met the Milan Criteria were treated by percutaneous thermal ablation using intra-procedural CT/MR-US fusion imaging. The HCC nodules were divided into subgroups and compared (≤ 3 cm and > 3 cm, or high-risk and low-risk location, or inconspicuous and conspicuous, respectively). Technique efficacy and major complication were calculated. Cumulative local tumor progression (LTP), tumor-free and overall survival rates were estimated with the Kaplan-Meier method. RESULTS CT/MR-US fusion imaging was successfully registered in 419 patients with 502 nodules. The technique efficacy rate of thermal ablation was 99.4 %. The major complication rate was 1.9 %. The cumulative LTP rates were 3.2 %, 5.6 % and 7.2 % at 1, 3, and 5 years, respectively. There were no significant differences for the comparisons of cumulative LTP rates between different subgroups (P = 0.541, 0.314, 0.329). The cumulative tumor-free survival rates were 74.8 %, 54.0 % and 37.5 % at 1, 3, and 5 years, respectively. The cumulative overall survival rates were 97.8 %, 87.1 % and 81.7 % at 1, 3, and 5 years, respectively. CONCLUSION Intra-procedural CT/MR-ultrasound fusion imaging is a useful technique for percutaneous liver thermal ablation. It could help to achieve satisfying survival outcomes for HCC patients who meet the Milan Criteria.
Collapse
Affiliation(s)
- Erjiao Xu
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Kai Li
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yinglin Long
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Liping Luo
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Qingjing Zeng
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Lei Tan
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Xuqi He
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Qiannan Huang
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yuxuan Wu
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Rongqin Zheng
- Department of Medical Ultrasonics, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
9
|
You Y, Long Y, Yan R, Luo L, Zhang M, Li L, Zeng Q, Li K, Zheng R, Xu E. Improving Ablation Safety for Hepatocellular Carcinoma Proximal to the Hilar Bile Ducts by Ultrasound-MR Fusion Imaging: A Preliminary Comparative Study. Front Oncol 2021; 11:570312. [PMID: 33732639 PMCID: PMC7957055 DOI: 10.3389/fonc.2021.570312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Accepted: 01/15/2021] [Indexed: 01/10/2023] Open
Abstract
Aim To explore whether ablation safety could be improved by ultrasound (US)-magnetic resonance (MR) fusion imaging for hepatocellular carcinoma (HCC) proximal to the hilar bile ducts (HBDs) through a preliminary comparative study. Methods Between January 2014 and June 2019, 18 HCC nodules proximal to the HBDs were included in a US-MR fusion imaging-assisted radiofrequency ablation (RFA) group (study group), while 13 HCC nodules in a similar location were included as a control group. For the study group, the tumor and adjacent bile ducts were outlined on preprocedural MR images. Procedural ablation planning was conducted to assess the feasibility of ablating the tumors while avoiding biliary injury. Such tumors were then ablated under US-MR fusion imaging guidance. The control group nodules were ablated under conventional ultrasound guidance. Baseline characteristics and outcomes were compared between the groups. Results After preprocedural assessment, 14 of 18 patients with tumors that were feasible to ablate underwent US-MR fusion imaging-assisted RFA. No biliary complications were observed in these 14 patients; the complication rate was significantly lower in the study group than in the control group (30.8%, 4/13) (P = 0.041). There was no significant difference in the technique efficacy rates [92.9% (13/14) versus 100% (13/13), P = 1] or local progression rates [7.1% (1/14) versus 7.7% (1/13), P = 1] between the study and control groups. Conclusions US-MR fusion imaging may be a non-invasive means for assisting RFA of HCC nodules proximal to the HBDs and ensuring ablation safety.
Collapse
Affiliation(s)
- Yujia You
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yinglin Long
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Ronghua Yan
- Department of Radiology, The Eighth Affiliated Hospital of Sun Yat-Sen University, Shenzhen, China
| | - Liping Luo
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Man Zhang
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Lu Li
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Qingjing Zeng
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Kai Li
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Rongqin Zheng
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Erjiao Xu
- Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.,Department of Medical Ultrasonics, The Eighth Affiliated Hospital of Sun Yat-Sen University, Shenzhen, China
| |
Collapse
|
10
|
Chiba A, Harada K, Ohashi Y, Numasawa K, Imai T, Hayasaka S. Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods. Radiol Phys Technol 2020; 13:92-97. [DOI: 10.1007/s12194-020-00556-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 01/30/2020] [Accepted: 02/01/2020] [Indexed: 01/21/2023]
|
11
|
Ultrasound fusion imaging technologies for guidance in ablation therapy for liver cancer. J Med Ultrason (2001) 2020; 47:257-263. [PMID: 32125577 DOI: 10.1007/s10396-020-01006-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 01/05/2020] [Indexed: 12/17/2022]
Abstract
With advances in imaging technology, images from ultrasound (US) and computed tomography (CT) or magnetic resonance imaging (MRI) can be displayed simultaneously and in real time, according to the angle of the transducer. CT/MR-US fusion imaging improves the visualization of inconspicuous hepatocellular carcinoma (HCC) and helps us to understand the three-dimensional relationship between the liver vasculature and HCC. US fusion imaging guidance facilitates improvement in the treatment response for HCC with poor conspicuity, and the rates of technical success of ablation and local tumor progression for inconspicuous HCC range from 94.4 to 100% and 0 to 8.3%, respectively. Moreover, the development of image fusion has made it possible to compare and overlay pre- and post-ablation US images. This US-US fusion imaging allows side-by-side comparison of the ablative margin, while US-US overlay fusion can visualize the ablative margin because the tumor image is projected onto the ablative hyperechoic zone. Thus, US-US overlay fusion guidance is highly effective for safety margin achievement in local ablation therapy for HCC, providing a lower risk of local tumor progression. This manuscript reviews the current status of ultrasound fusion imaging for percutaneous ablation therapy of HCC.
Collapse
|
12
|
Ju JX, Zeng QJ, Xu EJ, He XQ, Tan L, Huang QN, Li K, Zheng RQ. Intraprocedural contrast-enhanced ultrasound-CT/MR fusion imaging assessment in HCC thermal ablation to reduce local tumor progression: compared with routine contrast-enhanced ultrasound. Int J Hyperthermia 2020; 36:785-793. [PMID: 31431086 DOI: 10.1080/02656736.2019.1640899] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Purpose: To evaluate whether local tumor progression (LTP) would be further reduced when contrast-enhanced ultrasound (CEUS)-CT/MR fusion imaging was used as intraprocedural assessment method in hepatocellular carcinoma (HCC) thermal ablation compared with routine CEUS. Materials and methods: This prospective non-randomized study was conducted from December 2010 to July 2012. CEUS-CT/MR fusion imaging and routine CEUS were used for treatment response assessment in the ablation procedure of 146 HCCs and 122 HCCs, respectively. Supplementary ablations were performed immediately if necessary. The primary technique efficacy rate, LTP rate and overall survival (OS) rate were calculated. Results: For CEUS-CT/MR fusion imaging and routine CEUS, the technical success rate, technique efficacy rate and supplementary ablation rate were 86.3% (126/146) and 98.4% (120/122) (p = .000), 99.2% (125/126) and 94.2% (113/120) (p = .032), and 14.3% (18/126) and 4.2% (5/120) (p = .006), respectively. The cumulative LTP rate and OS rate were not significantly different between fusion imaging group and routine CEUS group. However, for lesions that were larger than 3 cm or close to major vessels (41 lesions in fusion imaging group and 44 lesions in routine CEUS group, who received transcatheter arterial chemoembolization before ablation), the cumulative LTP rate was significantly lower in fusion imaging group than in routine CEUS group (p = .032). Conclusion: Although intraprocedural CEUS-CT/MR fusion imaging has certain limitations in application, it might provide a potential more efficient method compared with routine CEUS in reducing LTP in HCC thermal ablation, especially for difficult ablation lesions.
Collapse
Affiliation(s)
- Jin-Xiu Ju
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Qing-Jing Zeng
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Er-Jiao Xu
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Xu-Qi He
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Lei Tan
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Qian-Nan Huang
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Kai Li
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| | - Rong-Qin Zheng
- Department of Medical Ultrasound, Third Affiliated Hospital of Sun Yat-Sen University , Guangzhou , China
| |
Collapse
|
13
|
Minami Y, Minami T, Takita M, Hagiwara S, Ida H, Ueshima K, Nishida N, Kudo M. Radiofrequency ablation for hepatocellular carcinoma: Clinical value of ultrasound-ultrasound overlay fusion for optimal ablation and local controllability. Hepatol Res 2020; 50:67-74. [PMID: 31301213 DOI: 10.1111/hepr.13407] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 06/20/2019] [Accepted: 07/07/2019] [Indexed: 12/11/2022]
Abstract
AIM To retrospectively investigate the potential benefit of ultrasound-ultrasound (US-US) overlay fusion guidance for local controllability of radiofrequency ablation (RFA) in the treatment of hepatocellular carcinoma (HCC). METHODS Patients (n = 101) with 121 HCCs (mean ± SD, 1.8 ± 0.7 cm) who underwent RFA guided by US-US overlay fusion were included in the retrospective study. By overlaying pre/postoperative US, the tumor image could be projected onto the ablative hyperechoic zone. The ablative margin could thereby be evaluated three-dimensionally during the RFA procedure. As a control group, all 325 patients with 453 HCCs who underwent conventional RFA during the same study period were selected. RESULTS The total number of RF needle insertions per tumor for ablation was significantly more in the US overlay fusion group (mean 1.9 vs. 1.2; P < 0.01). The technical success rates of ablation after a single session were 100% (101/101) and 96.6% (314/325) for the US overlay fusion group and the control group, respectively. For early assessment of RFA response, 5-mm safety margins were achieved in 89.3% (108/121) and 47.0% (213/453) of nodules in the US overlay fusion group and the control group, respectively (P < 0.01). During the follow-up period (median 19 months), the 2-year local tumor progression rates were 0.8% (1/121) and 6.0% (27/453) in the US overlay fusion group and the control group, respectively (P = 0.022, log-rank test). CONCLUSIONS US-US overlay fusion guidance can be highly effective for safety margin achievement in RFA for HCC, providing a lower risk of local tumor progression.
Collapse
Affiliation(s)
- Yasunori Minami
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Tomohiro Minami
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Masahiro Takita
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Satoru Hagiwara
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Hiroshi Ida
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Kazuomi Ueshima
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Naoshi Nishida
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| |
Collapse
|
14
|
Lv S, Long Y, Su Z, Zheng R, Li K, Zhou H, Qiu C, Yin T, Xu E. Investigating the Accuracy of Ultrasound-Ultrasound Fusion Imaging for Evaluating the Ablation Effect via Special Phantom-Simulated Liver Tumors. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:3067-3074. [PMID: 31447240 DOI: 10.1016/j.ultrasmedbio.2019.07.415] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 07/15/2019] [Accepted: 07/21/2019] [Indexed: 06/10/2023]
Abstract
The goal of this study was to investigate the accuracy of ultrasound-ultrasound (US-US) fusion imaging for evaluating the ablation effect via phantom-simulated liver tumors. Twenty special phantom models were established, ablated and divided into a complete ablation group (n = 10) and an incomplete ablation group (n = 10). US-US fusion imaging was performed to evaluate the ablation effect. Gross specimens were observed as a standard reference. In this US-US fusion imaging study, the registration success rate was 100% (20/20), and the assessment time was 3.8 ± 0.9 min. The accuracy rate of the evaluation was 100% (20/20). There was no significant difference in the residual pseudo-tumoral area between the evaluation with US-US fusion imaging and gross specimen observation (p = 0.811), and the measurement error was 1.1 ± 0.6 mm. In conclusion, the feasibility and accuracy of US-US fusion imaging when evaluating the ablation effect can be investigated with this phantom-simulated liver tumor ablation model in an ideal state.
Collapse
Affiliation(s)
- Shumin Lv
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China; Department of Medical Ultrasonics, Shenzhen University General Hospital, Shenzhen University Clinical Medical Academy, Shenzhen, Guangdong Province, China
| | - Yinglin Long
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China
| | - Zhongzhen Su
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China; Department of Medical Ultrasonics, Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai, Guangdong Province, China
| | - Rongqin Zheng
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China
| | - Kai Li
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China
| | - Huichao Zhou
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China
| | - Chen Qiu
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China
| | - Tinghui Yin
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China
| | - Erjiao Xu
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangdong Key Laboratory of Liver Disease Research, Guangzhou, Guangdong Province, China.
| |
Collapse
|
15
|
Healing Response of a Structural Hamstring Injury: Perfusion Imaging 8-Week Follow-Up. J Sport Rehabil 2019; 28:72-76. [PMID: 28872408 DOI: 10.1123/jsr.2017-0123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2017] [Revised: 07/17/2017] [Accepted: 08/06/2017] [Indexed: 11/18/2022]
Abstract
CONTEXT Hamstring injuries are frequently observed in various sports disciplines both in elite and recreational sport. OBJECTIVE To quantify intramuscular tissue perfusion via contrast-enhanced ultrasound in the acute phase and during the healing of a structural muscle injury confirmed by high-resolution magnetic resonance imaging. DESIGN Case study. SETTING Laboratory environment. PATIENT A 32-year-old wakeboarder (height = 176 cm, body weight = 76 kg, and body mass index = 24.5 kg/m2) with an acute indirect muscle injury of the semimembranosus muscle. MAIN OUTCOME MEASURES Average values of quantifiable contrast-enhanced ultrasound, represented as peak enhancement and wash-in area under the curve, as well as conventional ultrasound, 1.5T magnetic resonance imaging were assessed at 48-hour, 3-week, and 8-week postinjury. RESULTS Average values of the quantitative perfusion analysis at 48-hour and 8-week postinjury revealed an approximate 5-fold increase in peak enhancement, and the wash-in area under the curve increased more than 3-fold in the center of the lesion. Magnetic resonance imaging, performed 48 hours after the injury to gather reference data as gold standard, revealed a grade III structural muscle tear. CONCLUSIONS The authors are able to demonstrate significant changes in intramuscular tissue perfusion in the center of the structural lesion as well as in the adjacent tissue. Quantifiable contrast-enhanced ultrasound seems to be able to gather relevant data for the assessment and monitoring of muscle injuries and could be established as a valuable tool for further studies focusing on healing processes or therapeutic interventions.
Collapse
|
16
|
Zhao Y, Bo X, Wang C, Hu S, Zhang T, Lin P, He S, Gu G. Guided Punctures with Ultrasound Volume Navigation in Percutaneous Transforaminal Endoscopic Discectomy: A Technical Note. World Neurosurg 2018; 119:77-84. [PMID: 30071330 DOI: 10.1016/j.wneu.2018.07.185] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Revised: 07/19/2018] [Accepted: 07/21/2018] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Ultrasound volume navigation (UVN) has been widely used for accurate guidance and decreased radiation exposure. However, few studies have focused on the clinical significance of UVN in guiding percutaneous puncture in percutaneous transforaminal endoscopic discectomy (PTED). We evaluated UVN to guide percutaneous puncture in PTED. METHODS We retrospectively reviewed the medical records of 12 patients (8 men and 4 women), who had undergone PTED with the help of UVN or fluoroscopic guidance for lumbar disc herniation from November 2017 to December 2017. RESULTS The age of these 12 patients range was 26-71 years, and the body mass index range was 18.19-26.91 kg/m2. Of the 12 patients, 6 were in UVN group and 6 were in fluoroscopy group. The mean number of punctures was 1.00 in UVN group and 3.83 in fluoroscopy group. The mean exposure time was 3.60 and 13.80 seconds in UVN and fluoroscopy groups, respectively. The mean operation time was 48.17 minutes and 61.33 minutes in UVN and fluoroscopy groups, respectively. A positive relationship was found between operation time and exposure time (P < 0.05). All patients achieved excellent or good clinical outcomes. The Oswestry Disability Index and visual analog scales for leg pain and back pain all showed significant improvement after the procedure (P < 0.05). None of patients experienced a complication. CONCLUSIONS UVN decreased the number of puncture attempts, radiation exposure, and operation time compared with fluoroscopic guidance in PTED. Therefore, UVN is a feasible and efficient method for guiding percutaneous puncture in PTED.
Collapse
Affiliation(s)
- Yongzhao Zhao
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Xiaowan Bo
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Chuanfeng Wang
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Shuo Hu
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Tianqi Zhang
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Peijie Lin
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Shisheng He
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.
| | - Guangfei Gu
- Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.
| |
Collapse
|
17
|
Contrast-Enhanced Ultrasound as a New Investigative Tool in Diagnostic Imaging of Muscle Injuries-A Pilot Study Evaluating Conventional Ultrasound, CEUS, and Findings in MRI. Clin J Sport Med 2018; 28:332-338. [PMID: 28708711 DOI: 10.1097/jsm.0000000000000470] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). DESIGN Case series. SETTING Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). PATIENTS Fifteen patients who underwent an acute muscle injury were recruited. MAIN OUTCOME MEASURES The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. RESULTS All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. CONCLUSIONS Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.
Collapse
|
18
|
Jingjing LMD, Liping LMD, Yanjing ZMD, Yufang Z, Yanhong HMD, Tingting LMD, Xiaochun ,HMD. Analysis of Characteristics Microvessel Density of Thyroid Malignant and Benign Nodules on Contrast-Enhanced Ultrasonography. ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY 2018. [DOI: 10.37015/audt.2018.180819] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
|
19
|
Cha DI, Lee MW, Kim AY, Kang TW, Oh YT, Jeong JY, Chang JW, Ryu J, Lee KJ, Kim J, Bang WC, Shin DK, Choi SJ, Koh D, Seo BK, Kim K. Automatic image fusion of real-time ultrasound with computed tomography images: a prospective comparison between two auto-registration methods. Acta Radiol 2017; 58:1349-1357. [PMID: 28273740 DOI: 10.1177/0284185117693459] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.
Collapse
Affiliation(s)
- Dong Ik Cha
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Min Woo Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Ah Yeong Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Tae Wook Kang
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Young-Taek Oh
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Ja-Yeon Jeong
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Jung-Woo Chang
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Jiwon Ryu
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Kyong Joon Lee
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Jaeil Kim
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Won-Chul Bang
- Medical Imaging R&D Group, Health & Medical Equipment Business, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Dong Kuk Shin
- Infrastructure Technology Lab, R&D Center, Samsung Medison, Republic of Korea
| | - Sung Jin Choi
- Infrastructure Technology Lab, R&D Center, Samsung Medison, Republic of Korea
| | - Dalkwon Koh
- Infrastructure Technology Lab, R&D Center, Samsung Medison, Republic of Korea
| | - Bong Koo Seo
- Infrastructure Technology Lab, R&D Center, Samsung Medison, Republic of Korea
| | - Kyunga Kim
- Biostatistics and Clinical Epidemiology Center, Samsung Medical Center, Seoul, Republic of Korea
| |
Collapse
|
20
|
Bolten K, Fischer T, Bender YYN, Diederichs G, Thomas A. Pilot study of MRI/ultrasound fusion imaging in postpartum assessment of Cesarean section scar. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 50:520-526. [PMID: 27804175 DOI: 10.1002/uog.17349] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 09/17/2016] [Accepted: 10/21/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVE To evaluate prospectively the uterine scar after Cesarean section (CS) and the corresponding uterine region after vaginal delivery (VD) at 6 weeks postpartum using transabdominal (TAS) and transvaginal (TVS) sonography with magnetic resonance imaging (MRI) fusion to investigate whether fusion imaging allows standardized and reproducible identification of the scar location and measurement of uterine wall thickness compared with high-resolution MRI alone. METHODS Pelvic MRI was performed 6 weeks after delivery in 30 women (10 with planned CS (PCS), 10 with emergency CS (ECS) and 10 with VD). After transfer of MRI-DICOM datasets to the ultrasound system, the scar region after CS and the corresponding uterine region after VD were examined by TAS (5 MHz) and TVS (10 MHz) using smart fusion with MRI to guide visualization of the region in the corresponding sectional planes for both modalities. Vascularization of the scar region was determined as a percentage area using power Doppler ultrasound. Anterior (AW) and posterior (PW) uterine wall thickness was measured using TAS and TVS with fusion imaging and using MRI alone. RESULTS TVS with fusion imaging was applied successfully for uterine assessment at the end of the postpartum period in all women. TAS failed to identify the scar area in three women. Imaging techniques were similar in the evaluation of AW and PW thickness following VD. MRI and MRI/TVS fusion showed significant differences in AW thickness or scar area, in terms of the difference relative to PW thickness, in women with PCS and ECS (MRI: PCS, 4.3 mm; ECS, 4.2 mm; VD, 0.8 mm; P = 0.034; MRI/TVS fusion: PCS, 2.0 mm; ECS, 3.3 mm; VD, 0.0 mm; P = 0.01). The degree of vascularization in the scar region measured by power Doppler ultrasound was lower after PCS (13.1 ± 9.4%/area) and ECS (17.0 ± 8.2%/area) than after VD (34.6 ± 8.5%/area; P = 0.0017). CONCLUSION MRI/ultrasound fusion imaging can be performed in a reproducible manner for examination of the postpartum uterus. MRI/TVS fusion enables standardized identification of the CS scar location and vascularization is reduced in this area. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- K Bolten
- Department of Obstetrics, Charité - Universitätsmedizin Berlin Ringgold Standard Institution, Berlin, Germany
| | - T Fischer
- Department of Radiology, Charité - Universitätsmedizin Berlin Ringgold Standard Institution, Berlin, Germany
| | - Y Y-N Bender
- Department of Radiology, Charité - Universitätsmedizin Berlin Ringgold Standard Institution, Berlin, Germany
| | - G Diederichs
- Department of Radiology, Charité - Universitätsmedizin Berlin Ringgold Standard Institution, Berlin, Germany
| | - A Thomas
- Department of Obstetrics, Charité - Universitätsmedizin Berlin Ringgold Standard Institution, Berlin, Germany
| |
Collapse
|
21
|
Garnon J, Tricard T, Cazzato RL, Cathelineau X, Gangi A, Lang H. [Percutaneous renal ablation: Pre-, per-, post-interventional evaluation modalities and adapted management]. Prog Urol 2017; 27:971-993. [PMID: 28942001 DOI: 10.1016/j.purol.2017.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 08/20/2017] [Accepted: 08/23/2017] [Indexed: 01/21/2023]
Abstract
OBJECTIVES Ablative treatment (AT) rise is foreseen, validation of steps to insure good proceedings is needed. By looking over the process of the patient, this study evaluates the requirements and choices needed in every step of the management. METHODS We searched MEDLINE®, Embase®, using (MeSH) words and we looked for all the studies. Investigators graded the strength of evidence in terms of methodology, language and relevance. RESULTS Explanations of AT proposal rather than partial nephrectomy or surveillance have to be discussed in a consultation shared by urologist and interventional radiologist. Per-procedure choices depend on predictable ballistic difficulties. High volume, proximity of the hilum or of a risky organ are in favor of general anesthesia, cryotherapy and computed tomography/magnetic resonance imaging (CT/MRI). Percutaneous approach should be privileged, as it seems as effective as the laparoscopic approach. Early and delayed complications have to be treated both by urologist and radiologist. Surveillance by CT/MRI insure of the lack of contrast-enhanced in the treated area. Patients and tumors criteria, in case of incomplete treatment or recurrence, are the key of the appropriate treatment: surgery, second session of AT, surveillance. CONCLUSION AT treatments require patient's comprehension, excellent coordination of the partnership between urologist and radiologist and relevant choices during intervention.
Collapse
Affiliation(s)
- J Garnon
- Service d'imagerie interventionnelle, CHU de Strasbourg, 67000 Strasbourg, France
| | - T Tricard
- Service de chirurgie urologique, CHU de Strasbourg, 67000 Strasbourg, France.
| | - R L Cazzato
- Service d'imagerie interventionnelle, CHU de Strasbourg, 67000 Strasbourg, France
| | - X Cathelineau
- Département d'urologie, institut Montsouris, 75014 Paris, France; Université Paris-Descartes, 75006 Paris, France
| | - A Gangi
- Service d'imagerie interventionnelle, CHU de Strasbourg, 67000 Strasbourg, France
| | - H Lang
- Service de chirurgie urologique, CHU de Strasbourg, 67000 Strasbourg, France
| |
Collapse
|
22
|
Toshikuni N, Matsue Y, Ozaki K, Yamada K, Hayashi N, Tsuchishima M, Tsutsumi M. An Image Fusion System for Estimating the Therapeutic Effects of Radiofrequency Ablation on Hepatocellular Carcinoma. Radiol Oncol 2017; 51:263-269. [PMID: 28959162 PMCID: PMC5611990 DOI: 10.1515/raon-2017-0028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Accepted: 06/29/2017] [Indexed: 12/27/2022] Open
Abstract
Background During ultrasound-guided radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC), high echoic areas due to RFA-induced microbubbles can help calculate the extent of ablation. However, these areas also decrease visualization of target tumors, making it difficult to assess whether they completely cover the tumors. To estimate the effects of RFA more precisely, we used an image fusion system (IFS). Patients and methods We enrolled patients with a single HCC who received RFA with or without the IFS. In the IFS group, we drew a spherical marker along the contour of a target tumor on reference images immediately after administering RFA so that the synchronized spherical marker represented the contour of the target tumor on real-time ultrasound images. When the high echoic area completely covered the marker, we considered the ablation to be complete. We compared outcomes between the IFS and control groups. Results We enrolled 25 patients and 20 controls, and the baseline characteristics were similar between the two groups. The complete ablation rates during the first RFA session were significantly higher in the IFS group compared with those in the control group (88.0% vs. 60.0%, P = 0.041). The number of RFA sessions was significantly smaller in the IFS group compared with that in the control group (1.1 ± 0.3 vs. 1.5 ± 0.7, P = 0.016). Conclusions The study suggested that the IFS enables a more precise estimation of the effects of RFA on HCC, contributing to enhanced treatment efficacy and minimized patient burden.
Collapse
Affiliation(s)
- Nobuyuki Toshikuni
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Yasuhiro Matsue
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Kazuaki Ozaki
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Kaho Yamada
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Nobuhiko Hayashi
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Mutsumi Tsuchishima
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| | - Mikihiro Tsutsumi
- Department of Hepatology, Kanazawa Medical University, Uchinada, Ishikawa, Japan
| |
Collapse
|
23
|
Cha DI, Lee MW, Song KD, Oh YT, Jeong JY, Chang JW, Ryu J, Lee KJ, Kim J, Bang WC, Shin DK, Choi SJ, Koh D, Seo BK, Kim K. A prospective comparison between auto-registration and manual registration of real-time ultrasound with MR images for percutaneous ablation or biopsy of hepatic lesions. Abdom Radiol (NY) 2017; 42:1799-1808. [PMID: 28194514 DOI: 10.1007/s00261-017-1075-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To compare the accuracy and required time for image fusion of real-time ultrasound (US) with pre-procedural magnetic resonance (MR) images between positioning auto-registration and manual registration for percutaneous radiofrequency ablation or biopsy of hepatic lesions. METHODS This prospective study was approved by the institutional review board, and all patients gave written informed consent. Twenty-two patients (male/female, n = 18/n = 4; age, 61.0 ± 7.7 years) who were referred for planning US to assess the feasibility of radiofrequency ablation (n = 21) or biopsy (n = 1) for focal hepatic lesions were included. One experienced radiologist performed the two types of image fusion methods in each patient. The performance of auto-registration and manual registration was evaluated. The accuracy of the two methods, based on measuring registration error, and the time required for image fusion for both methods were recorded using in-house software and respectively compared using the Wilcoxon signed rank test. RESULTS Image fusion was successful in all patients. The registration error was not significantly different between the two methods (auto-registration: median, 3.75 mm; range, 1.0-15.8 mm vs. manual registration: median, 2.95 mm; range, 1.2-12.5 mm, p = 0.242). The time required for image fusion was significantly shorter with auto-registration than with manual registration (median, 28.5 s; range, 18-47 s, vs. median, 36.5 s; range, 14-105 s, p = 0.026). CONCLUSION Positioning auto-registration showed promising results compared with manual registration, with similar accuracy and even shorter registration time.
Collapse
|
24
|
Burgmans MC, den Harder JM, Meershoek P, van den Berg NS, Chan SXJM, van Leeuwen FWB, van Erkel AR. Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions. Cardiovasc Intervent Radiol 2017; 40:914-923. [PMID: 28204959 PMCID: PMC5409927 DOI: 10.1007/s00270-017-1607-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Accepted: 02/03/2017] [Indexed: 01/05/2023]
Abstract
Purpose To determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions. Materials and Methods CT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers. Results Mean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values. Conclusion The accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.
Collapse
Affiliation(s)
- Mark Christiaan Burgmans
- Department of Radiology, Leiden University Medical Centre, Albinusdreef 2, 2300 RC, Leiden, The Netherlands.
| | - J Michiel den Harder
- Department of Radiology, Leiden University Medical Centre, Albinusdreef 2, 2300 RC, Leiden, The Netherlands
| | - Philippa Meershoek
- Department of Radiology, Leiden University Medical Centre, Albinusdreef 2, 2300 RC, Leiden, The Netherlands.,Interventional and Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Nynke S van den Berg
- Interventional and Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Shaun Xavier Ju Min Chan
- Department of Interventional Radiology, Singapore General Hospital, Outram Road, Singapore, 169608, Singapore
| | - Fijs W B van Leeuwen
- Interventional and Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Arian R van Erkel
- Department of Radiology, Leiden University Medical Centre, Albinusdreef 2, 2300 RC, Leiden, The Netherlands
| |
Collapse
|
25
|
Wang SY, Chen XX, Li Y, Zhang YY. Application of Multimodality Imaging Fusion Technology in Diagnosis and Treatment of Malignant Tumors under the Precision Medicine Plan. Chin Med J (Engl) 2016; 129:2991-2997. [PMID: 27958232 PMCID: PMC5198535 DOI: 10.4103/0366-6999.195467] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Objective: The arrival of precision medicine plan brings new opportunities and challenges for patients undergoing precision diagnosis and treatment of malignant tumors. With the development of medical imaging, information on different modality imaging can be integrated and comprehensively analyzed by imaging fusion system. This review aimed to update the application of multimodality imaging fusion technology in the precise diagnosis and treatment of malignant tumors under the precision medicine plan. We introduced several multimodality imaging fusion technologies and their application to the diagnosis and treatment of malignant tumors in clinical practice. Date Sources: The data cited in this review were obtained mainly from the PubMed database from 1996 to 2016, using the keywords of “precision medicine”, “fusion imaging”, “multimodality”, and “tumor diagnosis and treatment”. Study Selection: Original articles, clinical practice, reviews, and other relevant literatures published in English were reviewed. Papers focusing on precision medicine, fusion imaging, multimodality, and tumor diagnosis and treatment were selected. Duplicated papers were excluded. Results: Multimodality imaging fusion technology plays an important role in tumor diagnosis and treatment under the precision medicine plan, such as accurate location, qualitative diagnosis, tumor staging, treatment plan design, and real-time intraoperative monitoring. Multimodality imaging fusion systems could provide more imaging information of tumors from different dimensions and angles, thereby offing strong technical support for the implementation of precision oncology. Conclusion: Under the precision medicine plan, personalized treatment of tumors is a distinct possibility. We believe that multimodality imaging fusion technology will find an increasingly wide application in clinical practice.
Collapse
Affiliation(s)
- Shun-Yi Wang
- Department of Ultrasound, Qinghai People's Hospital, Xining, Qinghai 810007, China
| | - Xian-Xia Chen
- Department of Ultrasound, Qinghai People's Hospital, Xining, Qinghai 810007, China
| | - Yi Li
- Department of Ultrasound, Qinghai People's Hospital, Xining, Qinghai 810007, China
| | - Yu-Ying Zhang
- Department of Ultrasound, Qinghai People's Hospital, Xining, Qinghai 810007, China
| |
Collapse
|
26
|
Complexity of Ultrasound and CT Fusion Examinations: Are They Feasible in the Daily Routine? AJR Am J Roentgenol 2016; 207:712-717. [DOI: 10.2214/ajr.16.16246] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
27
|
Sui X, Liu HJ, Jia HL, Fang QM. Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules. Exp Ther Med 2016; 12:783-791. [PMID: 27446276 DOI: 10.3892/etm.2016.3344] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 01/26/2016] [Indexed: 12/17/2022] Open
Abstract
The diagnostic value of contrast-enhanced ultrasound (CEUS) or real-time elastography (RTE) alone, as well as a combination of CEUS and RTE, in distinguishing benign from malignant thyroid nodules was investigated. Between August 2012 and June 2014, a total of 97 consecutive patients (50 male and 47 female patients; mean age, 48.6±12.4; age range, 27-70 years) with thyroid nodules referred for surgical treatment were examined by CEUS and RTE. The final diagnosis was obtained based on histological findings. Image analysis of the CEUS and RTE scans was performed. Considering the postoperative pathological results as the golden standard, a receiver operating characteristic (ROC) curve was constructed. Subsequently, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of CEUS alone, RTE alone and CEUS + RTE combination were calculated. Pathological examination showed 66 papillary carcinomas and 43 benign lesions, including 21 adenomas and 22 nodular goiters. The sensitivity, specificity, PPV, NPV and accuracy of CEUS were 81.82, 90.70, 93.10, 90.70 and 85.32%, respectively. In the case of RTE, the sensitivity, specificity, PPV, NPV and accuracy were 80.30, 88.37, 91.38, 88.37 and 83.49%, respectively. Furthermore, the combination of CEUS + RTE had a sensitivity of 95.45%, specificity of 95.35%, PPV of 96.92%, NPV of 95.35% and accuracy of 95.41%. Therefore, the CEUS + RTE combination showed a significantly higher sensitivity and specificity compared with CEUS or RTE alone (all P<0.05). Based on ROC analysis, the area under the curve (AUC) for CEUS, RTE and CEUS + RTE combination was 0.883, 0.863 and 0.959, respectively. The AUC of RTE alone was significantly lower compared with that of the CEUS + RTE combination. In conclusion, our results demonstrate that CEUS + RTE combination significantly increases the diagnostic performance for differential diagnosis of malignant and benign thyroid nodules compared with CEUS or RTE alone.
Collapse
Affiliation(s)
- Xin Sui
- Department of Ultrasound, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei 050051, P.R. China
| | - Huai-Jun Liu
- Department of Radiology, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei 050050, P.R. China
| | - Hong-Li Jia
- Department of Radiology, The First Hospital of Hebei Medical University, Shijiazhuang, Hebei 050051, P.R. China
| | - Qin-Mao Fang
- Department of Ultrasound, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei 050051, P.R. China
| |
Collapse
|
28
|
Eisele RM. Advances in local ablation of malignant liver lesions. World J Gastroenterol 2016; 22:3885-3891. [PMID: 27099433 PMCID: PMC4823240 DOI: 10.3748/wjg.v22.i15.3885] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2015] [Revised: 02/23/2016] [Accepted: 03/14/2016] [Indexed: 02/06/2023] Open
Abstract
Local ablation of liver tumors matured during the recent years and is now proven to be an effective tool in the treatment of malignant liver lesions. Advances focus on the improvement of local tumor control by technical innovations, individual selection of imaging modalities, more accurate needle placement and the free choice of access to the liver. Considering data found in the current literature for conventional local ablative treatment strategies, virtually no single technology is able to demonstrate an unequivocal superiority. Hints at better performance of microwave compared to radiofrequency ablation regarding local tumor control, duration of the procedure and potentially achievable larger size of ablation areas favour the comparably more recent treatment modality; image fusion enables more patients to undergo ultrasound guided local ablation; magnetic resonance guidance may improve primary success rates in selected patients; navigation and robotics accelerate the needle placement and reduces deviation of needle positions; laparoscopic thermoablation results in larger ablation areas and therefore hypothetically better local tumor control under acceptable complication rates, but seems to be limited to patients with no, mild or moderate adhesions following earlier surgical procedures. Apart from that, most techniques appear technically feasible, albeit demanding. Which technology will in the long run become accepted, is subject to future work.
Collapse
|
29
|
|
30
|
Wells SA, Hinshaw JL, Lubner MG, Ziemlewicz TJ, Brace CL, Lee FT. Liver Ablation: Best Practice. Radiol Clin North Am 2015; 53:933-71. [PMID: 26321447 DOI: 10.1016/j.rcl.2015.05.012] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Tumor ablation in the liver has evolved to become a well-accepted tool in the management of increasing complex oncologic patients. At present, percutaneous ablation is considered first-line therapy for very early and early hepatocellular carcinoma and second-line therapy for colorectal carcinoma liver metastasis. Because thermal ablation is a treatment option for other primary and secondary liver tumors, an understanding of the underlying tumor biology is important when weighing the potential benefits of ablation. This article reviews ablation modalities, indications, patient selection, and imaging surveillance, and emphasizes technique-specific considerations for the performance of percutaneous ablation.
Collapse
Affiliation(s)
- Shane A Wells
- Department of Radiology, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA.
| | - J Louis Hinshaw
- Department of Radiology, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA
| | - Meghan G Lubner
- Department of Radiology, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA
| | - Timothy J Ziemlewicz
- Department of Radiology, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA
| | - Christopher L Brace
- Department of Radiology, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA; Department of Biomedical Engineering, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA
| | - Fred T Lee
- Department of Radiology, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA; Department of Biomedical Engineering, University of Wisconsin, 600 Highland Avenue, CSC, Madison, WI 53792, USA
| |
Collapse
|