1
|
Owaki R, Aoki H, Toriuchi K, Inoue Y, Hayashi H, Takeshita S, Kakita H, Yamada Y, Aoyama M. AMPK activators suppress cholesterol accumulation in macrophages via suppression of the mTOR pathway. Exp Cell Res 2023; 432:113784. [PMID: 37730144 DOI: 10.1016/j.yexcr.2023.113784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 09/13/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023]
Abstract
Atherosclerosis is a persistent inflammatory state that contributes significantly to cardiovascular disease, a primary cause of mortality worldwide. Enhanced lipid uptake by macrophages and their transformation into foam cells play a key role in the development of atherosclerosis. Recent studies using in vivo mouse models indicated that activation of AMPK has anti-atherosclerotic effects by upregulating the expression of cholesterol efflux transporters in foam cells and promoting cholesterol efflux. However, the pathway downstream of AMPK that contributes to elevated expression of cholesterol efflux transporters remains unclear. In this study, we found that activation of AMPK by AICAR and metformin inhibits foam cell formation via suppression of mTOR in macrophages. Specifically, activation of AMPK indirectly reduced the phosphorylation level of mTOR at Ser2448 and promoted the expression of cholesterol efflux transporters and cholesterol efflux. These inhibitory effects on foam cell formation were counteracted by mTOR activators. Metformin, a more nonspecific AMPK activator than AICAR, appears to inhibit foam cell formation via anti-inflammatory effects in addition to suppression of the mTOR pathway. The results of this study suggest that the development of new drugs targeting AMPK activation and mTOR inhibition may lead to beneficial results in the prevention and treatment of atherosclerosis.
Collapse
Affiliation(s)
- Reina Owaki
- Department of Pathobiology, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan
| | - Hiromasa Aoki
- Department of Pathobiology, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan
| | - Kohki Toriuchi
- Department of Pathobiology, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan
| | - Yasumichi Inoue
- Department of Cell Signaling, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan
| | - Hidetoshi Hayashi
- Department of Cell Signaling, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan
| | - Satoru Takeshita
- Department of Pathobiology, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan; Department of Perinatal and Neonatal Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Hiroki Kakita
- Department of Pathobiology, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan; Department of Perinatal and Neonatal Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yasumasa Yamada
- Department of Perinatal and Neonatal Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Mineyoshi Aoyama
- Department of Pathobiology, Nagoya City University Graduate School of Pharmaceutical Sciences, 3-1 Tanabe-dori, Mizuho-ku, Nagoya, Aichi, 467-8603, Japan.
| |
Collapse
|
2
|
Adventitial injection of HA/SA hydrogel loaded with PLGA rapamycin nanoparticle inhibits neointimal hyperplasia in a rat aortic wire injury model. Drug Deliv Transl Res 2022; 12:2950-2959. [PMID: 35378720 DOI: 10.1007/s13346-022-01158-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/28/2022] [Indexed: 12/16/2022]
Abstract
Neointimal hyperplasia is a persistent complication after vascular interventions, and it is also the leading cause of vascular graft restenosis and failure after arterial interventions, so novel treatment methods are needed to treat this complication. We hypothesized that adventitial injection of HA/SA hydrogel loaded with PLGA rapamycin nanoparticle (hydrogel-PLGA-rapamycin) could inhibit neointimal hyperplasia in a rat aortic wire injury model. The HA/SA hydrogel was fabricated by the interaction of hyaluronic acid (HA), sodium alginate (SA), and CaCO3; and loaded with PLGA rapamycin nanoparticle or rhodamine uniformly. A SD rat aortic wire injury induced neointimal hyperplasia model was developed, the control group only received wire injury, the adventitial application group received 10 μL hydrogel-PLGA-rapamycin after wire injury, and the adventitial injection group received 10 μL hydrogel-PLGA-rapamycin injected into the aortic adventitia after wire injury. Tissues were harvested at day 21 and analyzed by histology and immunohistochemical staining. Hydrogel loaded with rhodamine can be successfully injected into the aortic adventitia and was encapsuled by the adventitia. The hydrogel could be seen beneath the adventitia after adventitial injection but was almost degraded at day 21. There was a significantly thinner neointima in the adventitial application group and adventitial injection group compared to the control group (p = 0.0009). There were also significantly fewer CD68+ (macrophages) cells (p = 0.0012), CD3+ (lymphocytes) cells (p = 0.0011), p-mTOR+ cells (p = 0.0019), PCNA+ cells (p = 0.0028) in the adventitial application and adventitial injection groups compared to the control group. The endothelial cells expressed arterial identity markers (Ephrin-B2 and dll-4) in all these three groups. Adventitial injection of hydrogel-PLGA-rapamycin can effectively inhibit neointimal hyperplasia after rat aortic wire injury. This may be a promising drug delivery method and therapeutic choice to inhibit neointimal hyperplasia after vascular interventions.
Collapse
|
3
|
Mori S, Hirano K, Takahara M, Shirai S, Makino K, Honda Y, Tsutsumi M, Kobayashi N, Yamawaki M, Ito Y. Accuracy of quantitative vessel analysis in endovascular treatment for femoropopliteal lesions. Quant Imaging Med Surg 2022; 12:568-575. [PMID: 34993102 DOI: 10.21037/qims-20-1097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Accepted: 07/07/2021] [Indexed: 11/06/2022]
Abstract
BACKGROUND Our aim was to evaluate the accuracy of quantitative vessel analysis (QVA) in measuring the reference vessel diameter (RVD) of femoropopliteal lesions. METHODS Between October 2014 and September 2015, 30 consecutive femoropopliteal lesions in 25 patients who underwent endovascular therapy (EVT) under intravascular ultrasound (IVUS) guidance were analyzed. RVDs measured using QVAsheath (calibrated using a 6-Fr sheath in the common femoral artery) and QVAruler (calibrated using a ruler on the angiography table) were compared to those obtained using IVUS as the reference values. RESULTS The mean QVAsheath-measured RVD was significantly larger than the mean IVUS-measured RVD (5.34±1.29 vs. 5.07±1.20 mm, P=0.001). In contrast, mean QVAruler-measured RVD was 4.60±1.04 mm, which was significantly smaller than both the mean IVUS- and mean QVAsheath-measured RVD (both P<0.001). Bland-Altman analysis revealed that the 95% limits of agreement versus IVUS ranged from -0.94 to 1.49 mm for QVAsheath and -1.69 to 0.76 mm for QVAruler, respectively. Agreement with tolerance of ±1.00 mm accounted for 88% of QVAsheath and 83% of QVAruler (P=0.60). The difference between QVA- and IVUS-measured RVDs was inversely correlated with the distance from the table (P=0.029 for QVAsheath and P=0.003 for QVAruler). CONCLUSIONS The accuracy of both QVAsheath and QVAruler in measuring RVD were similarly suboptimal. Over- and under-estimation of RVD is not rare in QVA.
Collapse
Affiliation(s)
- Shinsuke Mori
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Keisuke Hirano
- Department of Cardiology, Toyohashi Heart Center, Toyohashi, Japan
| | - Mitsuyoshi Takahara
- Department of Diabetes Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan
| | - Shigemitsu Shirai
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Kenji Makino
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Yohsuke Honda
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Masakazu Tsutsumi
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Norihiro Kobayashi
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Masahiro Yamawaki
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Yoshiaki Ito
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| |
Collapse
|
4
|
Vascular Response Toward an Absorbable Sirolimus-eluting Polymeric Scaffold for Vascular Application in a Model of Normal Porcine Carotid Arteries. Ann Vasc Surg 2021; 79:324-334. [PMID: 34648854 DOI: 10.1016/j.avsg.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 09/29/2021] [Accepted: 10/03/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND Fully absorbable polymeric scaffolds, as a potential alternative to permanent metallic stents, are entering the clinical field. The aim of this study is to assess the in vivo biocompatibility of a novel Sirolimus-eluting (SIR) absorbable scaffold based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for interventional application. METHODS Absorbable PLLA/P4HB scaffolds either loaded with SIR coating or unloaded scaffolds were implanted interventionally into common carotid arteries of 14 female. Bare metal stents (BMS) served as control. Peroral dual anti-platelet therapy was administered throughout the study. Stented common carotid arteries segments were explanted after 4 weeks, and assessed histomorphometrically. RESULTS The absorbable scaffolds showed a decreased residual lumen area and higher stenosis after 4 weeks (PLLA/P4HB: 6.56 ± 0.41 mm² and 37.56 ± 4.67%; SIR-PLLA/P4HB: 6.90 ± 0.58 mm² and 35.60 ± 3.15%) as compared to BMS (15.29 ± 1.86 mm² and 7.65 ± 2.27%). Incorporation of SIR reduced the significantly higher inflammation of unloaded scaffolds however not to a level compared to bare metal stent (PLLA/P4HB: 1.20 ± 0.19; SIR-PLLA/P4HB: 0.96 ± 0.24; BMS: 0.54 ± 0.12). In contrast, the BMS showed a slightly elevated vascular injury score (0.74 ± 0.15), as compared to the PLLA/P4HB (0.54 ± 0.20) and the SIR-PLLA/P4HB (0.48 ± 0.15) groups. CONCLUSION In this preclinical model, the new absorbable polymeric (SIR-) scaffolds showed similar technical feasability and safety for vascular application as the permanent metal stents. The higher inflammatory propensity of the polymeric scaffolds was slightly reduced by SIR-coating. A smaller strut thickness of the polymeric scaffolds might have been a positive effect on tissue ingrowth between the struts and needs to be addressed in future work on the stent design.
Collapse
|
5
|
Bai H, Wang Z, Li M, Sun P, Wei S, Wang W, Wang Z, Xing Y, Li J, Dardik A. Inhibition of programmed death‐1 decreases neointimal hyperplasia after patch angioplasty. J Biomed Mater Res B Appl Biomater 2020; 109:269-278. [PMID: 32770622 DOI: 10.1002/jbm.b.34698] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/19/2020] [Accepted: 07/22/2020] [Indexed: 02/06/2023]
Affiliation(s)
- Hualong Bai
- Department of Vascular and Endovascular Surgery First Affiliated Hospital of Zhengzhou University Zhengzhou Henan China
- Key Vascular Physiology and Applied Research Laboratory of Zhengzhou City Zhengzhou Henan China
| | - Zhiwei Wang
- Department of Vascular and Endovascular Surgery First Affiliated Hospital of Zhengzhou University Zhengzhou Henan China
| | - Mingxing Li
- Department of Vascular and Endovascular Surgery First Affiliated Hospital of Zhengzhou University Zhengzhou Henan China
| | - Peng Sun
- Department of Vascular and Endovascular Surgery First Affiliated Hospital of Zhengzhou University Zhengzhou Henan China
| | - Shunbo Wei
- Department of Vascular and Endovascular Surgery First Affiliated Hospital of Zhengzhou University Zhengzhou Henan China
| | - Wang Wang
- Department of Physiology Medical school of Zhengzhou University Zhengzhou Henan China
- Key Vascular Physiology and Applied Research Laboratory of Zhengzhou City Zhengzhou Henan China
| | - Zhiju Wang
- Department of Physiology Medical school of Zhengzhou University Zhengzhou Henan China
- Key Vascular Physiology and Applied Research Laboratory of Zhengzhou City Zhengzhou Henan China
| | - Ying Xing
- Department of Physiology Medical school of Zhengzhou University Zhengzhou Henan China
- Key Vascular Physiology and Applied Research Laboratory of Zhengzhou City Zhengzhou Henan China
| | - Jingan Li
- School of Material Science and Engineering and Henan Key Laboratory of Advanced Magnesium Alloy and Key Laboratory of materials processing and mold technology (Ministry of Education) Zhengzhou University Zhengzhou Henan China
| | - Alan Dardik
- The Vascular Biology and Therapeutics Program Yale School of Medicine New Haven Connecticut USA
- Departments of Surgery and of Cellular and Molecular Physiology Yale School of Medicine New Haven Connecticut USA
| |
Collapse
|
6
|
Chen W, Huang F, Li M, Jiang Y, He J, Li H, Dai Z, Shi W, Zhu M, Chen G, Yang F, Zhang R. Incidence and Predictors of the In-stent Restenosis after Vertebral Artery Ostium Stenting. J Stroke Cerebrovasc Dis 2018; 27:3030-3035. [PMID: 30093203 DOI: 10.1016/j.jstrokecerebrovasdis.2018.06.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2018] [Revised: 05/27/2018] [Accepted: 06/24/2018] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND The incidence and predictors for in-stent restenosis (ISR) was not fully explored. We aim to investigate the incidence and predictors of ISR after stenting at the origin of vertebral artery. MATERIALS AND METHODS Two hundred and six patients with 229 stents implantation between July 1, 2005 and July 31, 2015 were included in the study. All patients underwent conventional clinical and angiographic (digital subtraction angiography) follow-up at around 6 months post procedure. ISR was defined as greater than 50% stenosis within or immediately (within 5 mm) adjacent to the stent. Multivariate Cox regression analyses were utilized to investigate the predictors for ISR. RESULTS The ISR was found in 30 patients (30/206, 14.6%) with 31 lesions (31/229, 13.5%) with the mean follow-up duration of 11.1-month (range: 3 - 92 months). Stent diameter (hazard ratio 0.504, 95% confidence interval 0.294 - 0.864) was an independent predictor for ISR. CONCLUSION ISR rate after Vertebral artery ostium stent placement is acceptable, which was conversely associated with the stent diameter.
Collapse
Affiliation(s)
- Wanhong Chen
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province 210002; Department of Neurology, Xi'an XD group hospital, Xi'an, Shanxi Province 710077, China
| | - Fang Huang
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province 210002
| | - Min Li
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province 210002
| | - Yongjun Jiang
- Department of Neurology, Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong Province 510260
| | - Jianbo He
- Department of Neurology, Xi'an XD group hospital, Xi'an, Shanxi Province 710077, China
| | - Huiqi Li
- Department of Neurology, Xi'an XD group hospital, Xi'an, Shanxi Province 710077, China
| | - Zheng Dai
- Department of Neurology, Wuxi People's Hospital of Nanjing Medical University, Wuxi, Jiangsu Province 214023
| | - Wei Shi
- Department of Intensive Care Unit, The Affiliated Brain Hospital with Nanjing Medical University, Nanjing, Jiangsu Province 210009
| | - Mingyue Zhu
- Department of Intensive Care Unit, The Third Affiliated Hospitial of Nanjing University of Chinese Medicine, Nanjing, Jiangsu Province 210001, China
| | - Guanghui Chen
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province 210002
| | - Fang Yang
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province 210002.
| | - Renliang Zhang
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province 210002.
| |
Collapse
|
7
|
Is a bare-metal stent still useful for improving the outcome of percutaneous coronary intervention? From the FU-Registry. J Cardiol 2017; 69:652-659. [DOI: 10.1016/j.jjcc.2016.06.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Revised: 06/07/2016] [Accepted: 06/14/2016] [Indexed: 11/17/2022]
|
8
|
Hannan EL, Racz MJ, Walford G, Jacobs AK, Stamato NJ, Gesten F, Berger PB, Sharma S, King SB. Disparities in the Use of Drug-Eluting Coronary Stents by Race, Ethnicity, Payer, and Hospital. Can J Cardiol 2016; 32:987.e25-31. [DOI: 10.1016/j.cjca.2016.01.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 01/06/2016] [Accepted: 01/07/2016] [Indexed: 10/22/2022] Open
|
9
|
Suwannasom P, Onuma Y, Benit E, Gach O, von Birgelen C, Hofma SH, Sotomi Y, Bo X, Zhang YJ, Gao R, García-García HM, Wykrzykowska JJ, de Winter RJ, Serruys PW. Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging. EUROINTERVENTION 2016; 12:e574-83. [DOI: 10.4244/eijv12i5a97] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
10
|
Abstract
The authors discuss the mechanism of action, clinical trial data, and economic impact of both the paclitaxel and sirolimus drug eluting stents (DESs). Both DESs have been approved by the Food and Drug Administration for the treatment of native coronary arteries to prevent in-stent restenosis (ISR), which patients have experienced since the advent of balloon angioplasty and the bare metal stent. In-stent restenosis, which manifests itself as ischemic symptoms in patients, occurs as a result of the healing process after stent implantation. Until now, there has not been an effective method to prevent ISR. The sirolimus and paclitaxel DESs elute agents that act locally by different mechanisms to reduce neointimal hyperplasia, which is primarily responsible for ISR. Both DESs are capable of reducing the rate of ISR. There are certain physical and mechanistic differences between the 2 stents; the stents have not been compared head to head. Currently, they are indicated for uncomplicated native coronary lesions. Further investigation is needed to define their roles in the treatment of more complex lesions.
Collapse
Affiliation(s)
- William Alvarez
- The Johns Hopkins Hospital, Department of Pharmacy, 600 North Wolfe Street, Carnegie 180, Baltimore, MD 21287, The Johns Hopkins Hospital, Baltimore, Maryland
| | | |
Collapse
|
11
|
Gouveia V, Oliveira DC, Tenorio E, Brito N, Sarinho E. Percutaneous Coronary Intervention: Safety of Methotrexate and Its Possible Benefits on Restenosis After Bare-Metal Stent Deployment. Cardiol Res 2016; 7:104-109. [PMID: 28197276 PMCID: PMC5295516 DOI: 10.14740/cr468w] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/02/2016] [Indexed: 12/03/2022] Open
Abstract
Background Percutaneous coronary intervention (PCI) revolutionized treatment of coronary artery disease. Drug-eluting stents are effective and safe but their cost is high, especially for some countries. The primary objective was to evaluate the safety of methotrexate (MTX) in patients who underwent PCI and the secondary goal was to evaluate the possibility that MTX has an impact on restenosis. Methods This was a transversal, prospective and descriptive study that recruited 16 patients in whom PCI was planned. MTX was administered to patients at a dose of 5 mg/week for 2 weeks before PCI and 8 weeks after PCI. Bare-metal stent (BMS) deployment was performed according to standard practice. Patients were monitored clinically every 15 days during the first 2 months after the procedure and monthly until 9 months after PCI. Results There were no immediate or late complications associated with PCI. Adverse events and side effects due to MTX occurred in three patients (prevalence 18.7%). These side effects are classified as minor complications. MTX was not discontinued due to these side effects. There were no reported cases of clinical restenosis. Conclusions MTX was safe in the study population and raised the possibility that a low-cost drug may have positive effects on restenosis after BMS implantation. However, studies with larger sample sizes and other imagine modalities (intravascular ultrasound and/or optical coherence tomography) are required to confirm this hypothesis.
Collapse
Affiliation(s)
- Viviane Gouveia
- Hospital das Clinicas, Federal University of Pernambuco, Brazil
| | | | | | - Norma Brito
- Hospital das Clinicas, Federal University of Pernambuco, Brazil
| | - Emanuel Sarinho
- Hospital das Clinicas, Federal University of Pernambuco, Brazil
| |
Collapse
|
12
|
Nakata T, Fujii K, Fukunaga M, Shibuya M, Kawai K, Kawasaki D, Naito Y, Ohyanagi M, Masuyama T. Morphological, Functional, and Biological Vascular Healing Response 6 Months After Drug-Eluting Stent Implantation. Catheter Cardiovasc Interv 2015; 88:350-7. [DOI: 10.1002/ccd.26273] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Revised: 07/04/2015] [Accepted: 10/02/2015] [Indexed: 01/21/2023]
Affiliation(s)
- Tsuyoshi Nakata
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Kenichi Fujii
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Masashi Fukunaga
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Masahiko Shibuya
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Kenji Kawai
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Daizo Kawasaki
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Yoshiro Naito
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| | - Mitsumasa Ohyanagi
- Division of Coronary Heart Disease; Hyogo College of Medicine; Nishinomiya Japan
| | - Tohru Masuyama
- Cardiovascular Division; Hyogo College of Medicine; Nishinomiya Japan
| |
Collapse
|
13
|
Suga T, Iwanaga Y, Kobuke K, Morimoto K, Ikuta S, Ueno M, Kobayashi N, Yamaji K, Ikeda T, Miyazaki S. Clinical utility of low-pressure implantation of drug-eluting stent into very small vessels. J Cardiol 2014; 63:218-22. [PMID: 24646655 DOI: 10.1016/j.jjcc.2013.08.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Revised: 07/17/2013] [Accepted: 08/13/2013] [Indexed: 11/29/2022]
Abstract
BACKGROUND Although drug-eluting stents (DES) reduce restenosis, the best strategy for DES implantation in small vessels has not been established. PURPOSE We investigated the clinical usefulness of low-pressure implantation of a 2.5-mm DES for small vessels less than 2.5mm in diameter. METHODS In 118 patients, a 2.5-mm DES was implanted for small vessels less than 2.5mm in diameter between 2007 and 2009 in our hospital. The patients were divided into two groups by initial deployment pressure: low-pressure (LP; n=46) and nominal-pressure (NP; n=72). RESULTS Patients with impaired glucose tolerance were more frequent (p=0.02) and the target vessel diameter was significantly smaller (p=0.01) in the LP group than in the NP group. A smaller minimum lumen diameter (MLD) was obtained (LP: 2.22±0.27mm vs. NP: 2.34±0.26mm, p=0.02) after DES implantation with a smaller balloon-to-artery ratio (p=0.03) in the LP group. However, at mid-term follow-up (7.7±3.9 months), MLD (p=0.55) and the binary restenosis rate (LP: 2.6% vs. NP: 11.1%, p=0.12) were not significantly different between the LP and NP groups. Furthermore, by Kaplan-Meier analysis, the incidence of major adverse cardiac events was not different between the groups during the long-term follow-up (32.4±8.6 months). CONCLUSION The present study indicates that low-pressure implantation of 2.5-mm DES for very small vessels may be feasible with regard to short- and long-term clinical outcomes.
Collapse
Affiliation(s)
- Tatsuya Suga
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Yoshitaka Iwanaga
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Kazuhiro Kobuke
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Keisuke Morimoto
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Shinichiro Ikuta
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Masafumi Ueno
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Naoya Kobayashi
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Kenji Yamaji
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Tomoyuki Ikeda
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan
| | - Shunichi Miyazaki
- Division of Cardiology, Department of Internal Medicine, Kinki University Faculty of Medicine, Osakasayama, Japan.
| |
Collapse
|
14
|
Busch R, Strohbach A, Rethfeldt S, Walz S, Busch M, Petersen S, Felix S, Sternberg K. New stent surface materials: the impact of polymer-dependent interactions of human endothelial cells, smooth muscle cells, and platelets. Acta Biomater 2014; 10:688-700. [PMID: 24148751 DOI: 10.1016/j.actbio.2013.10.015] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Revised: 09/02/2013] [Accepted: 10/14/2013] [Indexed: 01/25/2023]
Abstract
Despite the development of new coronary stent technologies, in-stent restenosis and stent thrombosis are still clinically relevant. Interactions of blood and tissue cells with the implanted material may represent an important cause of these side effects. We hypothesize material-dependent interaction of blood and tissue cells. The aim of this study is accordingly to investigate the impact of vascular endothelial cells, smooth muscle cells and platelets with various biodegradable polymers to identify a stent coating or platform material that demonstrates excellent endothelial-cell-supportive and non-thrombogenic properties. Human umbilical venous endothelial cells, human coronary arterial endothelial cells and human coronary arterial smooth muscle cells were cultivated on the surfaces of two established biostable polymers used for drug-eluting stents, namely poly(ethylene-co-vinylacetate) (PEVA) and poly(butyl methacrylate) (PBMA). We compared these polymers to new biodegradable polyesters poly(l-lactide) (PLLA), poly(3-hydroxybutyrate) (P(3HB)), poly(4-hydroxybutyrate) (P(4HB)) and a polymeric blend of PLLA/P(4HB) in a ratio of 78/22% (w/w). Biocompatibility tests were performed under static and dynamic conditions. Measurement of cell proliferation, viability, glycocalix width, eNOS and PECAM-1 mRNA expression revealed strong material dependency among the six polymer samples investigated. Only the polymeric blend of PLLA/P(4HB) achieved excellent endothelial markers of biocompatibility. Data show that PLLA and P(4HB) tend to a more thrombotic response, whereas the polymer blend is characterized by a lower thrombotic potential. These data demonstrate material-dependent endothelialization, smooth muscle cell growth and thrombogenicity. Although polymers such as PEVA and PBMA are already commonly used for vascular implants, they did not sufficiently meet the criteria for biocompatibility. The investigated biodegradable polymeric blend PLLA/P(4HB) evidently represents a promising material for vascular stents and stent coatings.
Collapse
|
15
|
|
16
|
Abstract
The introduction of drug-eluting stents (DES) to interventional cardiology practice has resulted in a significant improvement in the long-term efficacy of percutaneous coronary interventions. DES successfully combine mechanical benefits of bare-metal stents and stabilizing the lumen, with direct delivery and the controlled elution of a pharmacologic agent to the injured vessel wall to suppress further neointimal proliferation. The dramatic reduction in restenosis has resulted in the implementation of DES in clinical practice, and has rapidly expanded the whole spectrum of successfully treatable coronary conditions, particularly in high-risk patients and complex lesions. In this review the authors present current data on DES. Currently, two types of DES are available in the USA: sirolimus-eluting stents (SES) CYPHER (Cordis Corp., FL, USA) and paclitaxel-eluting stents (PES) TAXUS (Boston Scientific, MA, USA), and many more are on the way to approval. In addition to sirolimus and paclitaxel, several other drugs have been successfully used in DES. Everolimus and ABT-578 are both analogs of sirolimus that also have immunosuppressive and antiproliferative properties. Another approach in the development of DES is to use drugs that can accelerate re-endothelialization and restore normal endothelial function following vascular injury. Recent advances in vascular gene transfer have also demonstrated potential new treatment modalities for cardiovascular disease, particularly in the treatment of vascular restenosis.
Collapse
Affiliation(s)
- Nicholas N Kipshidze
- Department of Interventional Cardiac and Vascular Services, Lenox Hill Hospital, New York, NY 10021, USA.
| | | | | | | | | |
Collapse
|
17
|
Discrepancies in vessel sizing between angiography and intravascular ultrasound varies according to the vessel evaluated. Int J Cardiol 2013; 168:3791-6. [DOI: 10.1016/j.ijcard.2013.06.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2012] [Revised: 01/01/2013] [Accepted: 06/15/2013] [Indexed: 11/22/2022]
|
18
|
Sauvageau E, Ecker RD, Levy EI, Hanel RA, Guterman LR, Hopkins LN. Recent advances in endoluminal revascularization for intracranial atherosclerotic disease. Neurol Res 2013; 27 Suppl 1:S89-94. [PMID: 16197832 DOI: 10.1179/016164105x35486] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
More than 750,000 strokes occur annually in the United States. Of these, 8-10% are due to intracranial atherosclerosis. Less than 50% of patients with strokes from intracranial atherosclerosis will have a transient ischemic attack. For those patients with symptomatic intracranial atherosclerosis, the prognosis is poor; and the recent Warfarin-Aspirin Symptomatic Intracranial Stenosis (WASID) trial results have demonstrated the high risk of warfarin without clear benefit. Intracranial angioplasty and stenting is emerging as a viable and effective treatment alternative for patients with symptomatic intracranial stenosis. Advances in stent design, endovascular wires, and catheters and balloons are allowing endovascular surgeons to safely treat intracranial atherosclerosis. Wider clinical experience has led to refinement of patient selection and endoluminal techniques. Drug eluting-stents have the promise of decreasing the risk of restenosis. In this review, the most recent clinical, laboratory, and technical details for the treatment of intracranial angioplasty and stenting are discussed.
Collapse
Affiliation(s)
- Eric Sauvageau
- Department of Neurosurgery and Toshiba Stroke Research Center, School of Medicine and Biomedical Sciences, State University of New York, University at Buffalo, Buffalo, New York 14209-1194, USA
| | | | | | | | | | | |
Collapse
|
19
|
Hannan EL, Zhong Y, Wu C, Walford G, Holmes DR, Jacobs AK, Stamato NJ, Venditti FJ, Sharma S, Fergus I, King SB. Everolimus-eluting stents and zotarolimus-eluting stents for percutaneous coronary interventions. Catheter Cardiovasc Interv 2013; 81:1097-105. [DOI: 10.1002/ccd.24512] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2012] [Accepted: 06/04/2012] [Indexed: 11/11/2022]
Affiliation(s)
- Edward L. Hannan
- University at Albany; State University of New York; Albany; New York
| | - Ye Zhong
- University at Albany; State University of New York; Albany; New York
| | - Chuntao Wu
- Penn State College of Medicine; Hershey; Pennsylvania
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Kocak B, Korkmazer B, Islak C, Kocer N, Kizilkilic O. Endovascular treatment of extracranial vertebral artery stenosis. World J Radiol 2012; 4:391-400. [PMID: 23024840 PMCID: PMC3460226 DOI: 10.4329/wjr.v4.i9.391] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2012] [Revised: 09/03/2012] [Accepted: 09/10/2012] [Indexed: 02/06/2023] Open
Abstract
Percutaneous angioplasty and stenting for the treatment of extracranial vertebral artery (VA) stenosis seems a safe, effective and useful technique for resolving symptoms and improving blood flow to the posterior circulation, with a low complication rate and good long-term results. In patients with severe tortuosity of the vessel, stent placement is a real challenge. The new coronary balloon-expandable stents may be preferred. A large variability of restenosis rates has been reported. Drug-eluting stents may be the solution. After a comprehensive review of the literature, it can be concluded that percutaneous angioplasty and stenting of extracranial VA stenosis is technically feasible, but there is insufficient evidence from randomized trials to demonstrate that endovascular management is superior to best medical management.
Collapse
|
21
|
Brinton MR, Tagge CA, Stewart RJ, Cheung AK, Shiu YTE, Christensen DA. Thermal sensitivity of endothelial cells on synthetic vascular graft material. Int J Hyperthermia 2012; 28:163-74. [DOI: 10.3109/02656736.2011.638963] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
|
22
|
Willich SN, Müller-Riemenschneider F, McBride D, Silber S, Kuck KH, Nienaber CA, Schneider S, Senges J, Brüggenjürgen B. Health economic evaluation of the use of drug-eluting stents : First results from the Drug-Eluting Stent Registry (DES.de). Herz 2012; 38:57-64. [PMID: 22301731 DOI: 10.1007/s00059-012-3581-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2011] [Revised: 12/21/2011] [Accepted: 12/24/2011] [Indexed: 10/14/2022]
Abstract
OBJECTIVE: The purpose of the economic evaluation of the German Drug-Eluting Stent (DES) registry includes the investigation of the economic impact and cost-effectiveness of DES compared to bare-metal stents (BMS) and between paclitaxel-eluting (PES) and sirolimus-eluting stents (SES). Here, methodology and initial results are presented. METHODS: Patients were recruited in 2005 and 2006 in 87 centres across Germany. Selection of PES, SES, or BMS was made at the discretion of the cardiologists in charge. Clinical, economic, and quality of life (QoL) data were collected at baseline and up to 12 months. Group comparisons were conducted using Fisher's exact and t test. RESULTS: Overall, 3,930 patients were enrolled: 3,471 (75% male, 65 ± 11 years) received DES and 458 (74% male, 67 ± 11 years) BMS. Among the DES patients, 1,821 received PES (75% male, 65 ± 10 years) and 1,600 SES (76% male, 65 ± 11 years). There were baseline differences in clinical and procedural characteristics but not in QoL. During the hospital stay, major adverse cardiac and cerebrovascular events occurred in 1.6% of DES (PES 1.9%, SES 1.1%) and 2.2% of BMS patients (BMS vs. DES, PES, and SES p = 0.327, 0.706, and 0.098, respectively). Hospital treatment costs were 4,989 ± 1,284 and 3,609 ± 924 , respectively, in DES and BMS patients (p < 0.001) with no significant difference between PES and SES. CONCLUSION: The economic evaluation of the large DES registry demonstrates increased initial hospitalisation costs associated with DES compared to BMS. Further analysis of the economic impact and cost-effectiveness of DES will provide estimates on large "real world" patient populations for decision makers and aid in reimbursement decisions of DES within the German and other health care systems.
Collapse
Affiliation(s)
- S N Willich
- Institute for Social Medicine, Epidemiology and Health Economics, Charité University Medical Center, Luisenstr. 57, 10117, Berlin, Germany,
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Brinton MR, Stewart RJ, Cheung AK, Christensen DA, Shiu YTE. Modelling ultrasound-induced mild hyperthermia of hyperplasia in vascular grafts. Theor Biol Med Model 2011; 8:42. [PMID: 22054016 PMCID: PMC3217891 DOI: 10.1186/1742-4682-8-42] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2011] [Accepted: 11/03/2011] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND Expanded polytetrafluoroethylene (ePTFE) vascular grafts frequently develop occlusive neointimal hyperplasia as a result of myofibroblast over-growth, leading to graft failure. ePTFE exhibits higher ultrasound attenuation than native soft tissues. We modelled the selective absorption of ultrasound by ePTFE, and explored the feasibility of preventing hyperplasia in ePTFE grafts by ultrasound heating. Specifically, we simulated the temperature profiles of implanted grafts and nearby soft tissues and blood under ultrasound exposure. The goal was to determine whether ultrasound exposure of an ePTFE graft can generate temperatures sufficient to prevent cell growth on the graft without damaging nearby soft tissues and blood. METHODS Ultrasound beams from two transducers (1.5 and 3.2 MHz) were simulated in two graft/tissue models, with and without an intra-graft cellular layer mimicking hyperplasia, using the finite-difference time-domain (FDTD) method. The resulting power deposition patterns were used as a heat source for the Pennes bioheat equation in a COMSOL(®) Multiphysics heat transfer model. 50°C is known to cause cell death and therefore the transducer powers were adjusted to produce a 13°C temperature rise from 37°C in the ePTFE. RESULTS Simulations showed that both the frequency of the transducers and the presence of hyperplasia significantly affect the power deposition patterns and subsequent temperature profiles on the grafts and nearby tissues. While neither transducer significantly raised the temperature of the blood, the 1.5-MHz transducer was less focused and heated larger volumes of the graft and nearby soft tissues than the 3.2-MHz transducer. The presence of hyperplasia had little effect on the blood's temperature, but further increased the temperature of the graft and nearby soft tissues in response to either transducer. Skin cooling and blood flow play a significant role in preventing overheating of the native tissues. CONCLUSIONS Modelling shows that ultrasound can selectively heat ePTFE grafts and produce temperatures that cause cell death on the graft. The temperature increase in blood is negligible and that in the adjacent soft tissues may be minimized by skin cooling and using appropriate transducers. Therefore, ultrasound heating may have the potential to reduce neointimal hyperplasia and failure of ePTFE vascular grafts.
Collapse
Affiliation(s)
- Mark R Brinton
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
- Department of Electrical Engineering, Stanford University, 350 Serra Mall (Mail Code: 9505), Stanford, CA 94305-9505, USA
| | - Russell J Stewart
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
| | - Alfred K Cheung
- Department of Medicine, Division of Nephrology & Hypertension, University of Utah, Salt Lake City, UT, USA
- Medical Service, Veterans Affairs Salt Lake City Healthcare System, UT, USA
| | - Douglas A Christensen
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
| | - Yan-Ting E Shiu
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
- Department of Medicine, Division of Nephrology & Hypertension, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
24
|
Abstract
The techniques and materials used during percutaneous coronary intervention have advanced considerably over the past 3 decades, yet restenosis remains one of the major drawbacks of this procedure. Many innovative technologies, including drug-eluting stents, with or without specific polymers, and fully biodegradable stents have been and continue to be developed in the search for a safe and effective antirestenosis therapy. Remarkable advances in stent design and nanoparticle delivery systems ('nanovehicles') have already fueled revolutionary changes in the prevention and treatment of in-stent restenosis. In this Review we provide an overview of the latest innovations for optimizing outcomes of coronary stenting, and up-to-date information about prevention and treatment of in-stent restenosis.
Collapse
|
25
|
|
26
|
Ali R, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar H, Kui-Hian S, Ong T, bin Ismail O, bin Elis S, Udychalerm W, Ackermann H, Boxberger M, Unverdorben M. Paclitaxel-eluting balloon angioplasty and cobalt-chromium stents versus conventional angioplasty and paclitaxel-eluting stents in the treatment of native coronary artery stenoses in patients with diabetes mellitus. EUROINTERVENTION 2011; 7 Suppl K:K83-92. [DOI: 10.4244/eijv7ska15] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
27
|
|
28
|
Sim DS, Jeong MH, Ahn Y, Kim YJ, Chae SC, Hong TJ, Seong IW, Chae JK, Kim CJ, Cho MC, Seung KB, Park SJ. Effectiveness of drug-eluting stents versus bare-metal stents in large coronary arteries in patients with acute myocardial infarction. J Korean Med Sci 2011; 26:521-7. [PMID: 21468259 PMCID: PMC3069571 DOI: 10.3346/jkms.2011.26.4.521] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2010] [Accepted: 02/08/2011] [Indexed: 12/30/2022] Open
Abstract
This study compared clinical outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in large coronary arteries in patients with acute myocardial infarction (MI). A total of 985 patients who underwent single-vessel percutaneous coronary intervention (PCI) in large coronary arteries (≥ 3.5 mm) in lesions < 25 mm were divided into DES group (n = 841) and BMS group (n = 144). Clinical outcomes during 12 months were compared. In-hospital outcome was similar between the groups. At six months, death/MI rate was not different. However, DES group had significantly lower rates of target-lesion revascularization (TLR) (1.7% vs 5.6%, P = 0.021), target-vessel revascularization (TVR) (2.2% vs 5.6%, P = 0.032), and total major adverse cardiac events (MACE) (3.4% vs 11.9%, P = 0.025). At 12 months, the rates of TLR and TVR remained lower in the DES group (2.5% vs 5.9%, P = 0.032 and 5.9% vs 3.1%, P = 0.041), but the rates of death/MI and total MACE were not statistically different. The use of DES in large vessels in the setting of acute MI is associated with lower need for repeat revascularization compared to BMS without compromising the overall safety over the course of one-year follow-up.
Collapse
Affiliation(s)
- Doo Sun Sim
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Musick KM, Coffey AC, Irazoqui PP. Sensor to detect endothelialization on an active coronary stent. Biomed Eng Online 2010; 9:67. [PMID: 21050471 PMCID: PMC2992534 DOI: 10.1186/1475-925x-9-67] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2010] [Accepted: 11/04/2010] [Indexed: 11/16/2022] Open
Abstract
Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks.
Collapse
Affiliation(s)
- Katherine M Musick
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA.
| | | | | |
Collapse
|
30
|
Kyono H, Guagliumi G, Sirbu V, Rosenthal N, Tahara S, Musumeci G, Trivisonno A, Bezerra H, Costa M. Optical coherence tomography (OCT) strut-level analysis of drug-eluting stents (DES) in human coronary bifurcations. EUROINTERVENTION 2010. [DOI: 10.4244/eijv6i1a11] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
31
|
In Vitro Evaluation of Metallic Coronary Artery Stents With 64-MDCT Using an ECG-Gated Cardiac Phantom: Relationship Between In-Stent Visualization, Stent Type, and Heart Rate. AJR Am J Roentgenol 2010; 194:W256-62. [DOI: 10.2214/ajr.09.2318] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
32
|
Chamié D, Costa JR, Abizaid A, Feres F, Staico R, Devito F, Costa RA, Abizaid A, Tanajura LF, Sousa AG, Fitzgerald PJ, Whitbourn RJ, Sousa JE. Serial Angiography and Intravascular Ultrasound: Results of the SISC Registry (Stents In Small Coronaries). JACC Cardiovasc Interv 2010; 3:191-202. [DOI: 10.1016/j.jcin.2009.11.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2009] [Revised: 11/03/2009] [Accepted: 11/13/2009] [Indexed: 10/19/2022]
|
33
|
Thermal Process for Enhancing Mechanical Strength of PLGA Nanoparticle Layers on Coronary Stents. B KOREAN CHEM SOC 2009. [DOI: 10.5012/bkcs.2009.30.9.1985] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
34
|
Impact of Vessel Size on Angiographic and Clinical Outcomes of Revascularization With Biolimus-Eluting Stent With Biodegradable Polymer and Sirolimus-Eluting Stent With Durable Polymer. JACC Cardiovasc Interv 2009; 2:861-70. [DOI: 10.1016/j.jcin.2009.05.024] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2009] [Accepted: 05/15/2009] [Indexed: 11/22/2022]
|
35
|
Zhang RY, Zhu ZB, Zhang Q, Yang ZK, Hu J, Lv AK, Zhang JS, Shen WF. Impact of moderate or severe renal insufficiency on long-term outcomes in patients undergoing drug-eluting stent based coronary intervention. Int J Cardiol 2009; 136:72-9. [DOI: 10.1016/j.ijcard.2008.04.028] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2007] [Revised: 02/26/2008] [Accepted: 04/23/2008] [Indexed: 11/25/2022]
|
36
|
Li Y, Zheng Z, Xu B, Zhang S, Li W, Gao R, Hu S. Comparison of drug-eluting stents and coronary artery bypass surgery for the treatment of multivessel coronary disease: three-year follow-up results from a single institution. Circulation 2009; 119:2040-50. [PMID: 19349321 DOI: 10.1161/circulationaha.108.819730] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Numerous studies have compared the outcomes of coronary artery bypass grafting (CABG) surgery and coronary stenting for the treatment of multivessel coronary disease. In 2003, drug-eluting stents were introduced with the hope of reducing restenosis. However, limited information exists on the comparison of drug-eluting stents and CABG surgery. The long-term outcome of drug-eluting stents compared with that of CABG surgery is also unclear. METHODS AND RESULTS We identified 3720 consecutive patients with multivessel disease who underwent isolated CABG surgery or received drug-eluting stents between April 1, 2004, and December 31, 2005, and we compared safety (total mortality, myocardial infarction, and stroke) and efficacy (target-vessel revascularization) during a 3-year follow-up. These outcomes were compared after adjustment for differences in baseline risk factors. Patients who underwent CABG (n=1886) were older and had more comorbidities than patients who received drug-eluting stents (n=1834). Patients receiving drug-eluting stents had considerably higher 3-year rates of target-vessel revascularization. Drug-eluting stents were also associated with higher rates of death (adjusted hazard ratio, 1.62; 95% confidence interval, 1.07 to 2.47) and myocardial infarction (adjusted hazard ratio, 1.65; 95% confidence interval, 1.15 to 2.44). The risk adjusted rate of stroke was similar in the 2 groups (hazard ratio, 0.92; 95% confidence interval, 0.69 to 1.51). CONCLUSIONS In a cohort of patients with multivessel disease, CABG was associated with lower rates of death, myocardial infarction, and target-vessel revascularization than drug-eluting stents.
Collapse
Affiliation(s)
- Yan Li
- Department of Cardiovascular Surgery, Cardiovascular Institute and Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | | | | | | | | | | | | |
Collapse
|
37
|
Alahmar AE, Grayson AD, Andron M, Egred M, Roberts ED, Patel B, Moore RK, Albouaini K, Jackson M, Perry RA. Reduction in mortality and target-lesion revascularisation at 2 years: A comparison between drug-eluting stents and conventional bare-metal stents in the “real world”. Int J Cardiol 2009; 132:398-404. [PMID: 18439692 DOI: 10.1016/j.ijcard.2008.03.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2007] [Revised: 01/22/2008] [Accepted: 03/01/2008] [Indexed: 10/22/2022]
|
38
|
Yao EH, Fukuda N, Ueno T, Matsuda H, Nagase H, Matsumoto Y, Sugiyama H, Matsumoto K. A pyrrole-imidazole polyamide targeting transforming growth factor-beta1 inhibits restenosis and preserves endothelialization in the injured artery. Cardiovasc Res 2008; 81:797-804. [PMID: 19098300 DOI: 10.1093/cvr/cvn355] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Although the use of drug-eluting stents (DESs) has been shown to limit neointima hyperplasia, currently available DESs may adversely affect re-endothelialization. To evaluate whether a novel gene silencer pyrrole-imidazole (PI) polyamide targeting transforming growth factor (TGF)-beta1 is a candidate agent for the DESs, we examined the effects of PI polyamide targeting the TGF-beta1 promoter on neointimal formation in rat carotid artery after balloon injury. METHODS AND RESULTS PI polyamide was designed to span the boundary of the AP-1 binding site of the TGF-beta1 promoter. After inducing balloon injury to arteries, incubation with PI polyamide was carried out for 10 min. Neointimal thickening and re-endothelialization were evaluated at 21 days after injury. Fluoresceinisothiocyanate-labelled PI polyamide was distributed into most of the nuclei in the injured artery without any delivery reagents. PI polyamide (100 microg) significantly inhibited neointimal thickening at 21 days after injury by 57%. PI polyamide targeting TGF-beta1 significantly decreased the expression of TGF-beta1 mRNA and protein in the artery at 3 days after injury and also suppressed the expression of connective tissue growth factor (CTGF), fibronectin, collagen type 1, and lectin-like ox-LDL receptor-1 mRNAs. A morphometric analysis showed that PI polyamide targeting TGF-beta1 accelerated re-endothelialization in the injured artery. CONCLUSION These findings suggest that the synthetic PI polyamide targeting the TGF-beta1 promoter may have the potential to suppress neointimal hyperplasia after arterial injury by the down-regulation of TGF-beta1 and CTGF and the reduction of the extracellular matrix. As a result, PI polyamide targeting TGF-beta1 may therefore be a potentially effective agent for the treatment of in-stent restenosis, as a candidate agent for the next-generation DES.
Collapse
Affiliation(s)
- En-Hui Yao
- Division of Nephrology, Hypertension and Endocrinology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Yang YJ, Kang S, Xu B, Chen JL, Qiao SB, Qin XW, Yao M, Chen J, Wu YJ, Liu HB, Yuan JQ, You SJ, Li JJ, Dai J, Gao RL. Short- and long-term outcomes of single bare metal stent versus drug eluting stent in nondiabetic patients with a simple de novo lesion in the middle and large vessel. J Transl Med 2008; 6:42. [PMID: 18684315 PMCID: PMC2546379 DOI: 10.1186/1479-5876-6-42] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2008] [Accepted: 08/06/2008] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE This study was aimed to investigate the short- and long-term outcomes of percutaneous coronary intervention (PCI) between single bare metal stent (BMS) and single drug eluting stent (DES) in nondiabetic patients with a simple de novo lesion in the middle and large vessel. METHODS Two hundred and thirty-five consecutive patients with a simple de novo lesion in the middle and large vessel were treated with BMS or DES in our hospital from Apr. 2004 to Dec. 2004. The inclusion criteria: a simple de novo lesion in the middle and large vessel, stent diameter > or = 3.0 mm, stent length < or = 18 mm, the exclusion criteria: diabetes mellitus, left main trunk disease and left ventricular ejection fraction < or = 30%. Of them, there were 150 patients in BMS group and 85 patients in DES group, and the rates of lost to follow up were 6.7% and 1.2% respectively. RESULTS BMS group had lower hypercholesteremia rate (22.0% vs 38.8%) and higher proportion of TIMI grade 0 (12% vs 1.2%) than DES group (all P < 0.05), but both groups had similar stent length (16.16 +/- 2.81 mm vs 16.06 +/- 2.46 mm) and stent diameter (3.85 +/- 3.07 mm vs 3.19 +/- 0.24 mm) after procedure, in-segment restenosis rate (0% vs 1.2%) and target lesion revascularization (TLR, 2.0% vs 2.4%) at 6-month follow-up (all P > 0.05). No difference was found in TLR (1.3% vs 1.2%, P = 1.00) and recurrent myocardial infarction (Re-MI) (0% vs 1.2%, P = 0.36), cardiac death (0.7% vs 1.2%, P = 1.00) between 1- and 3-year. So were TLR (6.0% vs 5.9%, P = 0.97), Re-MI (0% vs 2.4%, P = 0.06), cardiac death (2.0% vs 3.5%, P = 0.48) and major adverse cardiac events (MACE, 8.7% vs 10.6%, P = 0.63), cardiac death-free cumulative survival (98.7% vs 97.7%, P = 0.56), TLR-free cumulative survival (94.0% vs 94.1%, P = 0.98) and Re-MI-free cumulative survival (100% vs 97.7%, P = 0.06) at 3-year follow-up. CONCLUSION The single BMS has similar efficacy and safety to single DES in nondiabetic patients with a simple de novo lesion in the middle and large vessel at short- and long-term follow-up.
Collapse
Affiliation(s)
- Yue-jin Yang
- Department of Cardiology, Cardiovascular Institute & Fu Wai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Bei Li Shi Rd 167, Beijing, 100037, PR China.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Yao EH, Fukuda N, Ueno T, Matsuda H, Matsumoto K, Nagase H, Matsumoto Y, Takasaka A, Serie K, Sugiyama H, Sawamura T. Novel Gene Silencer Pyrrole-Imidazole Polyamide Targeting Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 Attenuates Restenosis of the Artery After Injury. Hypertension 2008; 52:86-92. [DOI: 10.1161/hypertensionaha.108.112797] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1) is a membrane protein that can support the binding, internalization, and proteolytic degradation of oxidized low-density lipoprotein. The LOX-1 expression increases in the neointima after balloon injury. To develop an efficient compound to inhibit LOX-1, we designed and synthesized a novel gene silencer pyrrole-imidazole (PI) polyamide targeting the rat LOX-1 gene promoter (PI polyamide to LOX-1) to the activator protein-1 binding site. We examined the effects of PI polyamide to LOX-1 on the LOX-1 promoter activity, the expression of LOX-1 mRNA and protein, and neointimal hyperplasia of the rat carotid artery after balloon injury. PI polyamide to LOX-1 significantly inhibited the rat LOX-1 promoter activity and decreased the expression of LOX-1 mRNA and protein. After balloon injury of the arteries, PI polyamide to LOX-1 was incubated for 10 minutes. Fluorescein isothiocyanate–labeled PI polyamide was distributed to almost all of the nuclei in the injured artery. PI polyamide to LOX-1 (100 μg) significantly inhibited the neointimal thickening by 58%. PI polyamide preserved the re-endothelialization in the injured artery. PI polyamide significantly inhibited the expression of LOX-1, monocyte chemoattractant protein-1, intercellular adhesion molecule-1, and matrix metalloproteinase-9 mRNAs in the injured artery. The synthetic PI polyamide to LOX-1 decreased the expression of LOX-1 and inhibited neointimal hyperplasia after arterial injury. This novel gene silencer PI polyamide to LOX-1 is, therefore, considered to be a feasible agent for the treatment of in-stent restenosis.
Collapse
Affiliation(s)
- En-Hui Yao
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Noboru Fukuda
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Takahiro Ueno
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Hiroyuki Matsuda
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Koichi Matsumoto
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Hiroki Nagase
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Yoshiaki Matsumoto
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Ayako Takasaka
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Kazuo Serie
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Hiroshi Sugiyama
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| | - Tatsuya Sawamura
- From the Division of Nephrology Hypertension and Endocrinology, Department of Medicine (E.-H.Y., N.F., T.U., H.M., K.M.), Division of Cancer Genetics, Department of Advanced Medical Science (H.N.), and Department of Cardiovascular Surgery (A.T.), Nihon University School of Medicine, Tokyo; Advanced Research Institute of the Sciences and Humanities (N.F., H.M., H.N.), Nihon University, Tokyo; Department of Clinical Pharmacokinetics (Y.M.), College of Pharmacy, Nihon University, Chiba; College of
| |
Collapse
|
41
|
Canibus P, Faloia E, Piva T, Muçai A, Serenelli M, Perna GP, Boscaro M, Piva R. Metabolic syndrome does not increase angiographic restenosis rates after drug-eluting stent implantation. Metabolism 2008; 57:593-7. [PMID: 18442619 DOI: 10.1016/j.metabol.2007.10.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2007] [Accepted: 10/29/2007] [Indexed: 12/19/2022]
Abstract
Metabolic syndrome (MS) is associated with an increased risk of coronary heart disease, stroke, and cardiovascular mortality; but its effect on patients undergoing cardiac revascularization is still unclear. Robust evidence demonstrates that diabetes mellitus and insulin resistance are among the main risk factors for restenosis in patients requiring percutaneous myocardial revascularization. The recent advent of drug-eluting stents (DESs) has significantly reduced the incidence of restenosis compared with bare-metal stents, both in nondiabetic and in diabetic patients. The aim of the study was to evaluate the effect of MS on the risk of binary restenosis in DES implant recipients. One hundred eighty-nine recipients of successful DES implants performed between January and March 2005 for stable coronary artery disease underwent 1-year clinical and angiographic follow-up. Body mass index (BMI), blood pressure, fasting blood glucose, and lipid profile were determined. Metabolic syndrome was defined according to the National Cholesterol Education Program Adult Treatment Panel III criteria, with the waist criterion being substituted by a BMI>or=28.8 kg/m2. Metabolic and anthropometric information for MS diagnosis was available for 148 of 189 patients; 87 of 148 patients (58%) had MS. Patients with MS had higher BMI (28.4+/-3.8 vs 26+/-2.7 kg/m2, P<.0001), systolic blood pressure (133+/-14 vs 124+/-14 mm Hg, P=.0004), and fasting glucose (113+/-37 vs 92+/-17 mg/dL, P<.0001). They also had higher serum triglycerides (154+/-94 vs 113+/-43, P=.0018) and lower high-density lipoprotein cholesterol levels (39+/-9 vs 46+/-10, P<.0001). Rates of restenosis (10.5% vs 8.1%, P=not significant [NS]), target vessel revascularization (10.5% vs 11.3%, P=NS), and major adverse cardiac events (11.6% vs 14.5%, P=NS) were not significantly different in patients with MS compared with those without MS, nor was any association found between increased end point risk and presence of MS. When patients were subdivided into 6 subgroups by the presence of 0, 1, 2, 3, 4, or 5 of the MS components, restenosis rates were not significantly different among subgroups. In conclusion, MS is not associated with higher rates of restenosis, target vessel revascularization, or major adverse cardiac events; and no additional MS feature was associated with an increased risk.
Collapse
Affiliation(s)
- Paola Canibus
- Division of Endocrinology, Polytechnic University of Marche, and Department of Cardiovascular Diseases, G.M. Lancisi Hospital, Ancona, Italy
| | | | | | | | | | | | | | | |
Collapse
|
42
|
Hannan EL, Racz M, Holmes DR, Walford G, Sharma S, Katz S, Jones RH, King SB. Comparison of coronary artery stenting outcomes in the eras before and after the introduction of drug-eluting stents. Circulation 2008; 117:2071-8. [PMID: 18391112 DOI: 10.1161/circulationaha.107.725531] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Few studies have compared medium-term outcomes for drug-eluting stents (DES) and bare metal stents, and most are relatively small randomized controlled trials. Furthermore, since the introduction of DES, there has been increased use and duration of use of clopidogrel, statins, and other evidence-based therapies. The purpose of the present study was to compare outcomes for patients who underwent stenting in the eras before and after the introduction of DES. METHODS AND RESULTS New York state patients undergoing stenting in all nonfederal hospitals in the state were studied. Patients were excluded if they had a previous revascularization. Risk factors that were significant predictors of adverse outcomes were used to adjust adverse outcome rates. The study included 11,436 patients who received stents between October 1, 2002, and March 31, 2003, and 12,926 patients who underwent stenting between October 1, 2003, and March 31, 2004. Death rates, the combined end point of death and myocardial infarction (MI), nonfatal MI requiring readmission, target vessel revascularization, and target lesion revascularization were compared at 2 years. Patients in the DES era had significantly better risk-adjusted outcomes for death/MI (adjusted hazard ratio, 0.90; 95% confidence interval, 0.83 to 0.97), 9.9% versus 10.8%; nonfatal MI requiring readmission (adjusted hazard ratio, 0.86; 95% confidence interval, 0.76 to 0.97); target vessel revascularization (adjusted hazard ratio, 0.60; 95% confidence interval, 0.56 to 0.64), 11.2% versus 17.9%; and target lesion revascularization (hazard ratio, 0.55; 95% confidence interval, 0.51 to 0.59), 8.4% versus 14.7%. CONCLUSIONS Patients in the DES era experienced lower rates of death/MI, nonfatal MI, target vessel revascularization, and target lesion revascularization, but there were no differences in the rates of death. These improvements are likely a result of increased use of clopidogrel, statins, and dual antiplatelet therapy, in addition to the introduction of DES.
Collapse
Affiliation(s)
- Edward L Hannan
- School of Public Health, State University of New York, University at Albany, One University Place, Rensselaer, NY 12144-3456, USA.
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Hannan EL, Racz M, Walford G, Holmes DR, Jones RH, Sharma S, Katz S, King SB. Drug-Eluting Versus Bare-Metal Stents in the Treatment of Patients With ST-Segment Elevation Myocardial Infarction. JACC Cardiovasc Interv 2008; 1:129-35. [DOI: 10.1016/j.jcin.2008.01.006] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2007] [Revised: 01/04/2008] [Accepted: 01/28/2008] [Indexed: 11/25/2022]
|
44
|
Le Feuvre C, Helft G, Cohen S, Batisse JP, Barthélémy O, Collet JP, Beygui F, Choussat R, Montalescot G, Metzger JP. Characteristics and prognosis of patients with angiographic stent thrombosis: comparison between drug-eluting and bare-metal stents. Arch Cardiovasc Dis 2008; 101:220-5. [DOI: 10.1016/s1875-2136(08)73696-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
45
|
Cheung AK, Terry C, Li L. Pathogenesis and local drug delivery for prevention of vascular access stenosis. J Ren Nutr 2008; 18:140-5. [PMID: 18089461 DOI: 10.1053/j.jrn.2007.10.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
A well-functioning vascular access is essential for hemodialysis in end-stage kidney disease patients. Synthetic grafts are more prone to the development of stenosis than native fistulas. Most of the stenosis is caused by neointimal hyperplasia localized at the outflow tract, which is perpetuated by continuous stimuli, such as blood flow disturbance, graft material bioincompatibility, and repeated needle puncture. Hyperplasia formation is also enhanced by the trauma of angioplasty. Recent work suggests that angiogenesis and the migration and proliferation of fibroblasts in the adventitia are important for the pathogenesis of neointimal hyperplasia. Therefore, the perivascular sustained delivery of antiproliferative drugs is a rational approach to inhibit hyperplasia associated with hemodialysis grafts. Because of the chronic nature of the stimuli, strategies that allow for the ready replenishment of the drug depot are preferable and are currently under development.
Collapse
Affiliation(s)
- Alfred K Cheung
- Veterans Affair Salt Lake City Healthcare System, Salt Lake City, Utah, USA.
| | | | | |
Collapse
|
46
|
Detection of In-Stent Restenosis of Coronary Stents Using 40-Detector Row Computed Tomography In Vitro. J Comput Assist Tomogr 2008; 32:252-8. [DOI: 10.1097/rct.0b013e318075e5e0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
47
|
Khattab A, Richardt G, Verin V, Kelbaek H, Macaya C, Berland J, Miquel-Hebert K, Dorange C, Serruys P. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial. EUROINTERVENTION 2008; 3:566-73. [DOI: 10.4244/eijv3i5a102] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
48
|
Technology insight: in vivo coronary plaque classification by intravascular ultrasonography radiofrequency analysis. ACTA ACUST UNITED AC 2008; 5:219-29. [PMID: 18301388 DOI: 10.1038/ncpcardio1123] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2007] [Accepted: 12/13/2007] [Indexed: 11/08/2022]
Abstract
Acute coronary syndromes or sudden coronary death are often the first manifestations of coronary artery disease. In the majority of patients, acute coronary syndrome events are caused by plaque rupture in flow-limiting and non-flow-limiting angiographically intermediate stenoses. Histopathologic analyses have shown that plaque composition is related to the occurrence of acute clinical events and, therefore, to the vulnerability of the plaque. The emerging importance of adaptive coronary remodeling processes, such as the compensatory enlargement of the coronary artery in response to initial lesion development, has focused our interest on the nonstenotic lesions of the coronary tree. In vivo intravascular ultrasonography can demonstrate the discrepancies between the actual extent of coronary atherosclerosis and that seen by angiographic imaging. The spectral analysis of intravascular ultrasonography derived radiofrequency data enables more precise analysis of plaque composition and type than grayscale intravascular ultrasonography.
Collapse
|
49
|
Hannan EL, Wu C, Walford G, Culliford AT, Gold JP, Smith CR, Higgins RSD, Carlson RE, Jones RH. Drug-eluting stents vs. coronary-artery bypass grafting in multivessel coronary disease. N Engl J Med 2008; 358:331-41. [PMID: 18216353 DOI: 10.1056/nejmoa071804] [Citation(s) in RCA: 353] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND Numerous studies have compared the outcomes of two competing interventions for multivessel coronary artery disease: coronary-artery bypass grafting (CABG) and coronary stenting. However, little information has become available since the introduction of drug-eluting stents. METHODS We identified patients with multivessel disease who received drug-eluting stents or underwent CABG in New York State between October 1, 2003, and December 31, 2004, and we compared adverse outcomes (death, death or myocardial infarction, or repeat revascularization) through December 31, 2005, after adjustment for differences in baseline risk factors among the patients. RESULTS In comparison with treatment with a drug-eluting stent, CABG was associated with lower 18-month rates of death and of death or myocardial infarction both for patients with three-vessel disease and for patients with two-vessel disease. Among patients with three-vessel disease who underwent CABG, as compared with those who received a stent, the adjusted hazard ratio for death was 0.80 (95% confidence interval [CI], 0.65 to 0.97) and the adjusted survival rate was 94.0% versus 92.7% (P=0.03); the adjusted hazard ratio for death or myocardial infarction was 0.75 (95% CI, 0.63 to 0.89) and the adjusted rate of survival free from myocardial infarction was 92.1% versus 89.7% (P<0.001). Among patients with two-vessel disease who underwent CABG, as compared with those who received a stent, the adjusted hazard ratio for death was 0.71 (95% CI, 0.57 to 0.89) and the adjusted survival rate was 96.0% versus 94.6% (P=0.003); the adjusted hazard ratio for death or myocardial infarction was 0.71 (95% CI, 0.59 to 0.87) and the adjusted rate of survival free from myocardial infarction was 94.5% versus 92.5% (P<0.001). Patients undergoing CABG also had lower rates of repeat revascularization. CONCLUSIONS For patients with multivessel disease, CABG continues to be associated with lower mortality rates than does treatment with drug-eluting stents and is also associated with lower rates of death or myocardial infarction and repeat revascularization.
Collapse
Affiliation(s)
- Edward L Hannan
- Department of Health Policy, Management, and Behavior, School of Public Health, University at Albany, Albany, NY 12144-3456, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Dabus G, Moran CJ, Derdeyn CP, Cross DT. Endovascular treatment of vertebral artery-origin and innominate/subclavian disease: indications and technique. Neuroimaging Clin N Am 2007; 17:381-92, ix. [PMID: 17826639 DOI: 10.1016/j.nic.2007.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Approximately 20% to 40% of patients who have cerebral vascular disease have a vertebral artery-origin stenosis. Atherosclerotic lesions of vertebral arety origin are a potential cause of posterior circulation ischemia, which can be disabling or deadly. Endovascular treatment of vertebral artery-origin and innominate/subclavian artery stenosis has changed in the last 15 years. Surgery usually is successful technically; however, it is also associated with high rates of procedural and periprocedural complications. New techniques and technologies that can be used in the treatment of such lesions are being developed. In this article, the authors discuss the indications, technical aspects, and long-term results of angioplasty and stenting of these vessels.
Collapse
Affiliation(s)
- Guilherme Dabus
- Division of Interventional Neuroradiology, Gray 241, Massachusetts General Hospital - Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA.
| | | | | | | |
Collapse
|