1
|
Michel-Behnke I, Kumar RK, Justo R, Zabal C, Marshall AC, Jacobs JP. Closing the gap between acceptable and ideal in catheterisation for paediatric and congenital heart disease-A global view. Cardiol Young 2024; 34:937-944. [PMID: 38699826 DOI: 10.1017/s1047951124000027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
In recent issues of the Journal of the Society for Cardiovascular Angiography and Interventions and the Journal of the American College of Cardiology: Cardiovascular Interventions, Holzer and colleagues presented an Expert Consensus Document titled: "PICS / AEPC / APPCS / CSANZ / SCAI / SOLACI: Expert consensus statement on cardiac catheterization for pediatric patients and adults with congenital heart disease." This Expert Consensus Document is a massively important contribution to the community of paediatric and congenital cardiac care. This document was developed as an Expert Consensus Document by the Pediatric and Congenital Interventional Cardiovascular Society, the Association for European Paediatric and Congenital Cardiology, the Asia-Pacific Pediatric Cardiac Society, the Cardiac Society of Australia and New Zealand, the Society for Cardiovascular Angiography and Interventions, and the Latin American Society of Interventional Cardiology, as well as the Congenital Cardiac Anesthesia Society and the American Association of Physicists in Medicine.As perfectly stated in the Preamble of this Expert Consensus Document, "This expert consensus document is intended to inform practitioners, payors, hospital administrators and other parties as to the opinion of the aforementioned societies about best practices for cardiac catheterisation and transcatheter management of paediatric and adult patients with congenital heart disease, with added accommodations for resource-limited environments." And, the fact that the authorship of this Expert Consensus Document includes global representation is notable, commendable, and important.This Expert Consensus Document has the potential to fill an important gap for this patient population. National guideline documents for specific aspects of interventions in patients with paediatric heart disease, including training guidelines, do exist. However, this current Expert Consensus Document authored by Holzer and colleagues provides truly globally applicable standards on cardiac catheterisation for both paediatric patients and adults with congenital heart disease (CHD).Our current Editorial provides different regional perspectives from senior physicians dedicated to paediatric and congenital cardiac care who are practicing in Europe, the Asia-Pacific region, Latin America, Australia/New Zealand, and North America. Establishing worldwide standards for cardiac catheterisation laboratories for children and adults with CHD is a significant stride towards improving the quality and consistency of care. These standards should not only reflect the current state of medical knowledge but should also be adaptable to future advancements, ultimately fostering better outcomes and enhancing the lives of individuals affected by CHD worldwide.Ensuring that these standards are accessible and adaptable across different healthcare settings globally is a critical step. Given the variability in resources and infrastructure globally, the need exists for flexibility and tailoring to implement recommendations.The potential impact of the Expert Consensus Document and its recommendations is likely significant, but heterogeneity of healthcare systems will pose continuing challenges on healthcare professionals. Indeed, this heterogeneity of healthcare systems will challenge healthcare professionals to finally close the gap between acceptable and ideal in the catheterisation of patients with paediatric and/or congenital heart disease.
Collapse
Affiliation(s)
- Ina Michel-Behnke
- Pediatric Heart Center Vienna, Division of Pediatric Cardiology, University Hospital for Children and Adolescent Medicine, Medical University Vienna, Vienna, Austria
| | | | - Robert Justo
- Queensland Children's Hospital, University of Queensland, South Brisbane, Australia
| | - Carlos Zabal
- CMO Instituto Nacional de Cardiologia Ignacio Chavez, Mexico City, Mexico
| | - Audrey C Marshall
- Hospital for Sick Children and the University of Toronto, Toronto, Ontario, Canada
| | - Jeffrey Phillip Jacobs
- Congenital Heart Center, Division of Cardiovascular Surgery, Departments of Surgery and Pediatrics, University of Florida, Gainesville, Florida, United States of America
| |
Collapse
|
2
|
Jiang Y, Luo F, Bu H. Percutaneous closure of simple congenital heart diseases under echocardiographic guidance. Eur J Med Res 2023; 28:408. [PMID: 37805534 PMCID: PMC10559656 DOI: 10.1186/s40001-023-01398-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 09/26/2023] [Indexed: 10/09/2023] Open
Abstract
Congenital heart disease (CHD), birth defect with the highest incidence rates worldwide, and is mainly characterized by the abnormal internal structure of the heart or/and the anatomical structure of great vessels. In the past few decades, CHD repair surgery through standard median sternotomy incision combined with cardiopulmonary bypass (CPB) technology has been considered the gold standard for surgical correction of heart and great vessels. With the promotion and clinical application of interventional catheterization technology, transcatheter closure of CHD under radioactive radiation has gradually been recognized and applied. However, its radiation exposure and potential complications related to arteriovenous vessels still face challenges. In recent years, an increasing number of surgeons have explored new surgical procedures, for the safe and effective treatment of CHD, as far as possible to reduce surgical trauma, avoid radiation exposure, and improve the cosmetic effect. Therefore, on the premise of satisfactory exposure or guidance, how to integrate ultrasound and percutaneous interventional technology remained the focus of the exploration. This mini-review highlights and summarizes the signs of progress of ultrasound intervention in the last decade that have proven the effectiveness and operability of a well-established procedure for percutaneous closure of congenital heart diseases under echocardiographic guidance only. We discuss potential diseases that will benefit from this emerging procedure based on this progress. Owing to the crucial advantages played by this strategy in the treatment of CHD, better understanding and promotion of this less exploited field may contribute to the development of therapeutics targeting CHD, improve medical utilization rate, promote the optimization of medical resources, and ultimately achieve precise and efficient medical treatment.
Collapse
Affiliation(s)
- Ying Jiang
- The Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, 410008, Hunan, People's Republic of China
| | - Fanyan Luo
- The Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, 410008, Hunan, People's Republic of China
| | - Haisong Bu
- The Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, 410008, Hunan, People's Republic of China.
| |
Collapse
|
3
|
Bu H, Yang Y, Wu Q, Hu S, Jin W, Gong X, Zhao T. Results of two different echocardiography-guided approaches to closure of perimembranous ventricular septal defects. Eur J Cardiothorac Surg 2021; 59:1304-1311. [PMID: 33532832 DOI: 10.1093/ejcts/ezab015] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 12/04/2020] [Accepted: 12/15/2020] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES The feasibility of mini-invasive closure of perimembranous ventricular septal defects has been proven, but can cause surgical incision or sternum injury. A relevant but, to date, unanswered question is whether there exists a treatment without surgical trauma, radiation exposure and arterial complications. METHODS From May 2017 to January 2020, a total of 449 patients with perimembranous ventricular septal defect [mean age 5.0 ± 6.1 years (range 0.8-52.0 years)] were involved in this study and underwent 2 different echocardiography-guided operative procedures [percutaneous device closure (group A) or percardiac device closure (group B)] based on the patients' or their parents' choice. The clinical data were collected and a retrospective analysis was performed. RESULTS Fifty-five (96.5%) cases were successfully occluded in group A, and 2 (3.5%) patients were converted to percardiac device closure; 379 (96.7%) patients in group B underwent percardiac device closure, and 13 patients (3.3%) were turned to open-heart surgery after occlusion procedure failure. There were statistically significant differences (P < 0.05) between the 2 groups in operation time, postoperative hospitalization time and blood transfusion requirement. No acute complications or severe adverse events (death, valve injury, complete atrioventricular block and embolism) occurred either in the early period or during the follow-up. CONCLUSIONS Percutaneous device closure can achieve the same validity and safety as percardiac device closure for treating perimembranous ventricular septal defects with a more rapid recovery and less trauma.
Collapse
Affiliation(s)
- Haisong Bu
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Yifeng Yang
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Qin Wu
- Department of Echocardiography, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Shijun Hu
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Wancun Jin
- Department of Echocardiography, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Xueyang Gong
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Tianli Zhao
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| |
Collapse
|
4
|
Bu H, Yang Y, Wu Q, Jin W, Zhao T. Echocardiography-guided percutaneous closure of perimembranous ventricular septal defects without arterial access and fluoroscopy. BMC Pediatr 2019; 19:302. [PMID: 31472688 PMCID: PMC6717354 DOI: 10.1186/s12887-019-1687-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Accepted: 08/22/2019] [Indexed: 11/21/2022] Open
Abstract
Background Traditional percutaneous device closure of perimembranous ventricular septal defects (PmVSDs) is a minimally invasive technique, but can result in high radiation exposure and can result in potential arterial complications. Here, we aimed to assess the safety and feasibility of device closure of PmVSDs via the femoral vein approach under transesophageal echocardiography (TEE) guidance in children. Methods From January 2014 to December 2017, a total of 46 PmVSD patients (mean age, 6.5 ± 2.3 years [range, 4.2–12.0 years]; mean body weight 22.1 ± 6.6 kg [range, 16.0–38.5 kg]; VSD diameter, 4.1 ± 0.6 mm [range, 3.2–5.0 mm]) underwent attempted transcatheter closure via the femoral vein approach under the guidance of TEE without fluoroscopy. Results The transcatheter occlusion procedure under TEE guidance was successful in 44 (95.7%) patients. Surgery was necessary in 2 (4.3%) patients. The procedure duration was 28.2 ± 8.7 min (range, 12.0–42.0 min). One patient had immediate post-operative trivial residual shunt and three patients had immediate incomplete right bundle branch block (IRBBB) after operation; the new IRBBB in 1 case was noted in the first postoperative month. No residual shunt was noted at 3 months after the procedure, and no intervention related complications were detected at 1–24 months follow-up. Conclusions Percutaneous device closure of PmVSDs under TEE guidance solely by femoral vein approach is effective and safe, avoids radiation exposure, potential arterial complications and a surgical incision. Electronic supplementary material The online version of this article (10.1186/s12887-019-1687-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Haisong Bu
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, 139 Renmin Road, Changsha, 410011, Hunan, China
| | - Yifeng Yang
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, 139 Renmin Road, Changsha, 410011, Hunan, China
| | - Qin Wu
- Department of Echocardiography, The Second Xiangya Hospital, Central South University, 139 Renmin Road, Changsha, 410011, Hunan, China
| | - Wancun Jin
- Department of Echocardiography, The Second Xiangya Hospital, Central South University, 139 Renmin Road, Changsha, 410011, Hunan, China
| | - Tianli Zhao
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, 139 Renmin Road, Changsha, 410011, Hunan, China.
| |
Collapse
|
5
|
Sierad LN, Shaw EL, Bina A, Brazile B, Rierson N, Patnaik SS, Kennamer A, Odum R, Cotoi O, Terezia P, Branzaniuc K, Smallwood H, Deac R, Egyed I, Pavai Z, Szanto A, Harceaga L, Suciu H, Raicea V, Olah P, Simionescu A, Liao J, Movileanu I, Harpa M, Simionescu DT. Functional Heart Valve Scaffolds Obtained by Complete Decellularization of Porcine Aortic Roots in a Novel Differential Pressure Gradient Perfusion System. Tissue Eng Part C Methods 2016; 21:1284-96. [PMID: 26467108 DOI: 10.1089/ten.tec.2015.0170] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
There is a great need for living valve replacements for patients of all ages. Such constructs could be built by tissue engineering, with perspective of the unique structure and biology of the aortic root. The aortic valve root is composed of several different tissues, and careful structural and functional consideration has to be given to each segment and component. Previous work has shown that immersion techniques are inadequate for whole-root decellularization, with the aortic wall segment being particularly resistant to decellularization. The aim of this study was to develop a differential pressure gradient perfusion system capable of being rigorous enough to decellularize the aortic root wall while gentle enough to preserve the integrity of the cusps. Fresh porcine aortic roots have been subjected to various regimens of perfusion decellularization using detergents and enzymes and results compared to immersion decellularized roots. Success criteria for evaluation of each root segment (cusp, muscle, sinus, wall) for decellularization completeness, tissue integrity, and valve functionality were defined using complementary methods of cell analysis (histology with nuclear and matrix stains and DNA analysis), biomechanics (biaxial and bending tests), and physiologic heart valve bioreactor testing (with advanced image analysis of open-close cycles and geometric orifice area measurement). Fully acellular porcine roots treated with the optimized method exhibited preserved macroscopic structures and microscopic matrix components, which translated into conserved anisotropic mechanical properties, including bending and excellent valve functionality when tested in aortic flow and pressure conditions. This study highlighted the importance of (1) adapting decellularization methods to specific target tissues, (2) combining several methods of cell analysis compared to relying solely on histology, (3) developing relevant valve-specific mechanical tests, and (4) in vitro testing of valve functionality.
Collapse
Affiliation(s)
- Leslie Neil Sierad
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Eliza Laine Shaw
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Alexander Bina
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Bryn Brazile
- 2 Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University , Starkville, Mississippi
| | - Nicholas Rierson
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Sourav S Patnaik
- 2 Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University , Starkville, Mississippi
| | - Allison Kennamer
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Rebekah Odum
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Ovidiu Cotoi
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Preda Terezia
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Klara Branzaniuc
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Harrison Smallwood
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Radu Deac
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Imre Egyed
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Zoltan Pavai
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Annamaria Szanto
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Lucian Harceaga
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Horatiu Suciu
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Victor Raicea
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Peter Olah
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Agneta Simionescu
- 4 Cardiovascular Tissue Engineering and Regenerative Medicine Laboratory, Department of Bioengineering, Clemson University , Clemson, South Carolina
| | - Jun Liao
- 2 Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University , Starkville, Mississippi
| | - Ionela Movileanu
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Marius Harpa
- 3 Tissue Engineering and Regenerative Medicine Laboratory, Department of Anatomy, University of Medicine and Pharmacy , Targu Mures, Romania
| | - Dan Teodor Simionescu
- 1 Biocompatibility and Tissue Regeneration Laboratories, Department of Bioengineering, Clemson University , Clemson, South Carolina
| |
Collapse
|
6
|
Yang Y, Zhang W, Wu Q, Gao L, Jin W, Zhao T. Transcatheter closure of atrial septal defects without fluoroscopy: a well-established procedure for alternative use in children. EUROINTERVENTION 2016; 12:e652-7. [DOI: 10.4244/eijv12i5a106] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
7
|
Ghelani SJ, Glatz AC, David S, Leahy R, Hirsch R, Armsby LB, Trucco SM, Holzer RJ, Bergersen L. Radiation dose benchmarks during cardiac catheterization for congenital heart disease in the United States. JACC Cardiovasc Interv 2015; 7:1060-9. [PMID: 25234681 DOI: 10.1016/j.jcin.2014.04.013] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Revised: 03/28/2014] [Accepted: 04/10/2014] [Indexed: 10/24/2022]
Abstract
OBJECTIVES The aim of this study was to define age-stratified, procedure-specific benchmark radiation dose levels during interventional catheterization for congenital heart disease. BACKGROUND There is a paucity of published literature with regard to radiation dose levels during catheterization for congenital heart disease. Obtaining benchmark radiation data is essential for assessing the impact of quality improvement initiatives for radiation safety. METHODS Data were obtained retrospectively from 7 laboratories participating in the Congenital Cardiac Catheterization Project on Outcomes collaborative. Total air kerma, dose area product, and total fluoroscopy time were obtained for the following procedures: 1) patent ductus arteriosus closure; 2) atrial septal defect closure; 3) pulmonary valvuloplasty; 4) aortic valvuloplasty; 5) treatment of coarctation of aorta; and 6) transcatheter pulmonary valve placement. RESULTS Between January 2009 and July 2013, 2,713 cases were identified. Radiation dose benchmarks are presented including median, 75th percentile, and 95th percentile. Radiation doses varied widely between age groups and procedure types. Radiation exposure was lowest in patent ductus arteriosus closure and highest in transcatheter pulmonary valve placement. Total fluoroscopy time was a poor marker of radiation exposure and did not correlate well with total air kerma and dose area product. CONCLUSIONS This study presents age-stratified radiation dose values for 6 common congenital heart interventional catheterization procedures. Fluoroscopy time alone is not an adequate measure for monitoring radiation exposure. These values will be used as baseline for measuring the effectiveness of future quality improvement activities by the Congenital Cardiac Catheterization Project on Outcomes collaborative.
Collapse
Affiliation(s)
- Sunil J Ghelani
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts
| | - Andrew C Glatz
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - Sthuthi David
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts
| | - Ryan Leahy
- Division of Cardiology, University of Louisville, Louisville, Kentucky
| | - Russel Hirsch
- Cincinnati Children's Medical Center, Cincinnati, Ohio
| | | | - Sara M Trucco
- Children's Hospital of Pittsburgh, Pittsburgh, Pennsylvania
| | - Ralf J Holzer
- The Heart Center, Nationwide Children's Hospital, Columbus, Ohio
| | - Lisa Bergersen
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts.
| |
Collapse
|
8
|
Radiation exposure in children during the current era of pediatric cardiac intervention. Pediatr Cardiol 2012; 33:27-35. [PMID: 21811814 DOI: 10.1007/s00246-011-0064-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Accepted: 07/08/2011] [Indexed: 11/27/2022]
Abstract
Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The fluoroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose-area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm(2) vs. 13.239 ± 15.4 Gy/cm(2); P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm(2)/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for therapeutic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.
Collapse
|
9
|
Qureshi SA, Redington AN, Wren C, Ostman-Smith I, Patel R, Gibbs JL, de Giovanni J. Recommendations of the British Paediatric Cardiac Association for therapeutic cardiac catheterisation in congenital cardiac disease. Cardiol Young 2000; 10:649-67. [PMID: 11117403 DOI: 10.1017/s1047951100008982] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The aims of these recommendations are to improve the outcome for patients after, and to provide acceptable standards of practice of therapeutic cardiac catheterisation performed to treat congenital cardiac disease. The scope of the recommendations includes all interventional procedures, recognising that for some congenital malformations, surgical treatment is equally as effective as, or occasionally preferable to, interventional treatment. The limitations of the recommendations are that, at present, no data are available which compare the results of interventional treatment with surgery, and certainly none which evaluate the numbers and types of procedures that need to be performed for the maintenance of skills. Thus, there is a recognised need to collect comprehensive data with which these recommendations could be reviewed in the future, and re-written as evidence-based guidelines. Such a review will have to take into account the methods of collection of data, their effectiveness, and the latest developments in technology. The present recommendations should, therefore, be considered as consensus statements, and as describing accepted practice, which could be used as a basis for ensuring and improving the quality of future care.
Collapse
|
10
|
Affiliation(s)
- M E Brickner
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas 75235-9047, USA
| | | | | |
Collapse
|
11
|
Alcíbar Villa J, García Fernández E, Gutiérrez-Larraya Aguado F, Moreno Granado F, Pan Alvarez-Osorio M, Santos de Soto J. [Guidelines of clinical practice of the Spanish Society of Cardiology. Requirements and equipment of invasive techniques in pediatric cardiology: clinical application]. Rev Esp Cardiol 1999; 52:688-707. [PMID: 10523881 DOI: 10.1016/s0300-8932(99)74990-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Invasive techniques in pediatric cardiology have experienced a big change since the 80's. The growth of non-invasive methods for diagnosing congenital heart defects has made the number of diagnostic catheterizations decrease remarkably. On the other hand, the notable development of pediatric interventional catheterization techniques will allow that, in the near future, the number of therapeutic catheterizations overcomes the diagnostic ones in our country. The former are more difficult and dangerous, so they require experienced and skilled hands and more economic resources. This chapter is divided in three main sections: I) Requirements and equipment needed for pediatric invasive techniques; II) Current indications, contraindications and complications of the diagnostic catheterization, and III) Techniques, indications and results of pediatric therapeutic catheterization: current state. Likewise, we state the suitability or not for these therapeutic procedures in different cardiac anomalies.
Collapse
|
12
|
Massoud I, Imam A, Mabrouk A, Boutros N, Kassem A, Daouod A, El Hakem MA. Palliative balloon valvoplasty of the pulmonary valve in tetralogy of Fallot. Cardiol Young 1999; 9:24-36. [PMID: 10323535 DOI: 10.1017/s1047951100007344] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Balloon dilation of the pulmonary valve was performed in 54 patients with tetralogy of Fallot with severe cyanosis, high haematocrit and severe valvar pulmonary stenosis. Clinical, echocardiographic, angiographic, and haemodynamic data were analyzed before and after the procedure. After balloon dilation, the systemic oxygen saturation increased from a mean value of 66% to 85%. The mean value of the haematocrit before dilation was 55 + 13, and decreased to 47 after dilation (p < 0.002) in 2 months follow-up. Balloon dilation increased the size of the pulmonary valvar orifice from a mean value of 9 + 5 mm to 11.5 + 2 mm (p < 0.005). The mean Z score of the pulmonary valves, which was -3 + 1.3 before dilation, increased to -1.1 + 1.1 immediately after the procedure (p < 0.05). The size of the right and left pulmonary arteries increased after dilation from 9 mm to 10 mm, and from 8.7 + 2.4 mm to 9.8 + 2.3 mm, respectively (p < 0.05). The comparable mean Z scores increased from -2.8 + 1.9 SD to -1.8 + 1.4 SD, and from -2.4 + 1.9 SD to -1.5 + 1.6 SD for the right and left branches, respectively (p < 0.05). In patients with stenosis at the bifurcation of the pulmonary trunk and hypoplasia of the left artery, successful dilation of the pulmonary valve lead to an increase of flow and improvement in size of the hypoplastic segment. In conclusion, initial balloon dilation of the pulmonary valve in tetralogy of Fallot resulted in increase of the Z score for the pulmonary valve and improved antegrade pulmonary blood flow, inducing growth of the pulmonary arteries and ameliorating the anatomic and physiologic preoperative condition.
Collapse
Affiliation(s)
- I Massoud
- Department of Pediatric Cardiology, National Heart Institute, Imbaba, Giza, Egypt
| | | | | | | | | | | | | |
Collapse
|
13
|
Braun J, Hazekamp MG, Koolbergen DR, Sugihara H, Goffin YA, Huysmans HA, Cornelisse CJ. Identification of host and donor cells in porcine homograft heart valve explants by fluorescence in situ hybridization. J Pathol 1997; 183:99-104. [PMID: 9370954 DOI: 10.1002/(sici)1096-9896(199709)183:1<99::aid-path1086>3.0.co;2-l] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The pathogenesis of the primary tissue degeneration that limits the life-span of aortic and pulmonary homografts has still not been revealed. Histopathological studies on homograft explants have not given definitive insight into the eventual fate of donor cells, nor have they demonstrated the assumed importance of host cell ingrowth into the graft tissue. In this experimental study, fluorescence in situ hybridization (FISH) is introduced as a new approach to examine the distribution of host and donor cells in homograft explants. Aortic valve replacement was performed with a cryopreserved porcine aortic homograft in three pigs; donor and recipient were of opposite sex. After 4 months, the grafts were explanted and examined by FISH using a biotinylated porcine Y-chromosome-specific library probe. Following probe detection with FITC-conjugated avidin, a clear distinction could be made between cells of host and donor origin without distorting the histological integrity of the explants. There was ingrowth of donor cells into the graft aortic wall and into the valve leaflet, to some extent. In all explants, remaining donor cells were present, though decreased in number. The introduction of FISH in homograft heart valve research provides a powerful tool to study the fate of recipient and donor cellular elements in situ, and may therefore contribute to a better understanding of the histopathological processes that take place in transplanted homograft valves.
Collapse
Affiliation(s)
- J Braun
- Department of Cardiothoracic Surgery, University of Leiden, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
14
|
Boothroyd A, McDonald E, Moores BM, Sluming V, Carty H. Radiation exposure to children during cardiac catheterization. Br J Radiol 1997; 70:180-5. [PMID: 9135445 DOI: 10.1259/bjr.70.830.9135445] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
The purpose of this study was to assess the suitability of different radiation dosimetry methods and record radiation exposures during paediatric catheterization. Three methods of dosimetry were employed: thermoluminescent dosimetry (TLD), dose-area product and calculation of entrance surface dose from calibrated exposure factors. Examinations included bi-plane fluoroscopy, and cineangiography for diagnosis and treatment of congenital heart disease. The most suitable method of radiation dosimetry for cardiac catheterization is the use of calculated entrance dose or a dose-area product meter. Children were exposed to high levels of radiation during cardiac catheterization but there was a wide variation in radiation dosage. Careful consideration should be given to the suitability of radiation dosimetry for cardiac catheterization.
Collapse
Affiliation(s)
- A Boothroyd
- Department of Radiology, Royal Liverpool Children's NHS Trust, UK
| | | | | | | | | |
Collapse
|
15
|
Quek SC, Wong J, Tay JS, Reidy J, Qureshi SA. Transcatheter embolization of coronary artery fistula with controlled release coils. J Paediatr Child Health 1996; 32:542-4. [PMID: 9007788 DOI: 10.1111/j.1440-1754.1996.tb00971.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The treatment for large congenital coronary cameral fistulas has been surgical but with advances in interventional catheterization techniques transcatheter embolization of these fistulas with coils or detachable balloons is now possible. This report describes occlusion of a congenital coronary arteriovenous fistula in a 6-year-old girl.
Collapse
Affiliation(s)
- S C Quek
- Department of Paediatrics, National University Hospital, Singapore
| | | | | | | | | |
Collapse
|
16
|
Shimokawa S, Matsumoto H, Ogata S, Komokata T, Nishida S, Ushijima T, Saigenji H, Moriyama Y, Taira A. A new experimental model for simultaneous evaluation of aortic and pulmonary allograft performance in a composite graft. J INVEST SURG 1996; 9:487-93. [PMID: 8981222 DOI: 10.3109/08941939609025866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
A model was developed in pigs for simultaneous evaluation of aortic and pulmonary allograft performance in a composite graft. The composite graft consisted of vascular prosthesis and aortic and pulmonary allografts. Following antibiotic preservation, it was anastomosed to the recipient's thoracic descending aorta by an extrapleural approach without using cardiopulmonary bypass. Aortic blood flow was completely diverted into the composite graft. All 12 recipient pigs recovered well, 4 of which were assigned for the initial study to design the suitable experimental schedule. Calcification readily occurred in the aortic allografts and aneurysmal dilatation without calcification developed in the pulmonary allografts. These morphological findings were consistent with those of previous reports. This model has several benefits. First, aortic and pulmonary allograft conduits can be implanted and evaluated simultaneously under the same conditions by making a composite graft. Second, the magnitude of the operation is minimum, and postoperative circulatory and respiratory management is uncomplicated. Third, wound infection rarely occurs, because the skin incision is made on the back. These preliminary studies suggest that this model will allow future study concerning aortic and pulmonary allograft conduits under different conditions.
Collapse
Affiliation(s)
- S Shimokawa
- Second Department of Surgery, Kagoshima University Faculty of Medicine, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Hopkins RA, Reyes A, Imperato DA, Carpenter GA, Myers JL, Murphy KA. Ventricular outflow tract reconstructions with cryopreserved cardiac valve homografts. A single surgeon's 10-year experience. Ann Surg 1996; 223:544-53; discussion 553-4. [PMID: 8651745 PMCID: PMC1235179 DOI: 10.1097/00000658-199605000-00010] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE From January 1, 1985 through December 31, 1994, one surgeon implanted cryopreserved valved homografts into 149 patients--65 since December 1988. This latter series (II) was accomplished in a single hospital, facilitating patient follow-up with biannual echocardiograms. Analysis of these 65 patients is the primary focus of this report; the indications and early surgical results for the two parts of the series (I and II) are compared to assess the evolution of a single surgeon's use of homografts in a mixed pediatric and adult practice. METHODS Fifty-one variables for each patient (series II) were entered into a computerized database and analyzed (multivariate and univariate) using SPSS 6.1 software (Statistical Products and Service Solutions, Chicago, IL). Cox proportional hazard model was used to identify the independent contribution of each variable for patient mortality and homograft failure. Cumulative survival estimates were made using Kaplan-Meier analysis. Homograft failure was defined as requirement for replacement or death. In series I, there were 41 left ventricular outflow tract (LVOT) reconstructions (31 adult) and 43 right ventricular outflow tract (RVOT) reconstructions (42 pediatric). In series II, there were 55 RVOT reconstructions (52 pediatric) and 10 LVOT reconstructions (7 adult). RESULTS There were no technical surgical failures. Total surgical mortality rate was 6% (5/84) in series I (3 LVOT, 2 RVOT) and 15% (10/65) in series II (2 LVOT, 8 RVOT) (I vs. II NS; p = 0.11, two-tailed Fisher exact test). By the Cox analysis, only age < 2 years (p < 0.03) and cross-clamp time > 120 minutes (p < 0.05) were significant predictors for death. Age-based survival curves were compared in a sequential bivariate analyses (log rank test) and age < 2 years again was a significant predictor of decreased patient survival (p < 0.006). Actuarial freedom from patient death or reoperation for homograft failure was 82% +/- 7% at 1000 days and 77% +/- 10% at 2000 days. Three patients required re-replacement for homograft failure (5.4%); one of these patients died. The only significant predictor of homograft failure was postoperative endocarditis (p < 0.05). Homograft performance was evaluated by an extensive echocardiography protocol: in surviving patients and homografts, three valved conduits were judged to have severely impaired performance (stenosis or regurgitation), awaiting surgical replacement for a putative total homograft-related structural failures rate of 11% at 5 1/2 years. CONCLUSIONS Comparisons of series I and II shows, in one surgeon's practice, an evolution away from use of cryopreserved homografts for LVOT reconstructions except when needed for destructive bacterial endocarditis or complex congenital anatomy. Homograft efficacy and durability were similar in RVOT and LVOT positions, with 78.5% of patients surviving at 5 1/2 years; in surviving patients, 89% of homografts have continued to function well. Homografts are not immune to prosthetic bacterial endocarditis, and its occurrence is associated with accelerated deterioration. Cryopreserved homograft valves are an imperfect but satisfactory biological material for specific ventricular outflow reconstructions.
Collapse
Affiliation(s)
- R A Hopkins
- Division of Cardiac Surgery, Georgetown University Medical Center, Washington, District of Columbia 20007, USA
| | | | | | | | | | | |
Collapse
|
18
|
Schranz D, Michel-Behnke I, Schmid FX, Oelert H. Gradual angioplasty and stent implantation to treat complete superior vena cava occlusion after Mustard procedure. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1996; 38:87-90; discussion 91. [PMID: 8722867 DOI: 10.1002/(sici)1097-0304(199605)38:1<87::aid-ccd20>3.0.co;2-o] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
A 16-year-old male was admitted with complete occlusion of the superior vena cava pathway 14 years after Mustard procedure for transposition of the great arteries. From a left subclavian vein approach, the atretic vein segment was perforated using a straight guidewire, and was followed by sequential balloon dilation. Implantation of a 30 mm Palmaz-stent through a femoral vein approach resulted in a widely patent channel of the vena cava superior into the systemic venous atrium.
Collapse
Affiliation(s)
- D Schranz
- Department of Pediatric Cardiology, University of Mainz, Germany
| | | | | | | |
Collapse
|
19
|
|
20
|
Javorski JJ, Hansen DD, Laussen PC, Fox ML, Lavoie J, Burrows FA. Paediatric cardiac catheterization: innovations. Can J Anaesth 1995; 42:310-29. [PMID: 7788828 DOI: 10.1007/bf03010708] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
In recent years interventional procedures have been introduced to the field of paediatric cardiac catheterization. These procedures continue to develop in complexity and increasingly are being applied to patients with reduced cardiovascular reserve, as an alternative to cardiac surgery or when cardiac surgery with cardiopulmonary bypass is contraindicated. More frequently anaesthetists are being called upon to provide support in sedating, anaesthetizing or/and resuscitating these patients. The purpose of this review is to give a comprehensive update of the interventional procedures and to review the anaesthetic management techniques as they apply to the catheterization laboratory. We will discuss possible complications and management strategies from our own experience and the experience of others. We have observed that as more complicated procedures are performed the anaesthetist plays a pivotal role in the management of the patient from arrival to departure from the cardiac catheterization laboratory, and in preventing mortality and major morbidity. Although the economic consequences of interventional cardiological techniques remain unclear, the field continues to expand and more complex procedures are continually being introduced.
Collapse
Affiliation(s)
- J J Javorski
- Department of Anesthesia (Division of Cardiac Anesthesia), Children's Hospital, Boston, MA 02115, USA
| | | | | | | | | | | |
Collapse
|
21
|
|