1
|
Ono M, Kawashima H, Hara H, Gao C, Wang R, Kogame N, Takahashi K, Chichareon P, Modolo R, Tomaniak M, Wykrzykowska JJ, Piek JJ, Mori I, Courtney BK, Wijns W, Sharif F, Bourantas C, Onuma Y, Serruys PW. Advances in IVUS/OCT and Future Clinical Perspective of Novel Hybrid Catheter System in Coronary Imaging. Front Cardiovasc Med 2020; 7:119. [PMID: 32850981 PMCID: PMC7411139 DOI: 10.3389/fcvm.2020.00119] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/05/2020] [Indexed: 12/14/2022] Open
Abstract
Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been developed and improved as both diagnostic and guidance tools for interventional procedures over the past three decades. IVUS has a resolution of 100 μm with a high tissue penetration and capability of assessing the entire structure of a coronary artery including the external elastic membrane, whereas OCT has a higher resolution of 10–20 μm to assess endoluminal structures with a limited tissue penetration compared to IVUS. Recently, two companies, CONAVI and TERUMO, integrated IVUS and OCT into a single catheter system. With their inherent strength and limitations, the combined IVUS and OCT probes are complementary and work synergistically to enable a comprehensive depiction of coronary artery. In this review, we summarize the performance of the two intracoronary imaging modalities—IVUS and OCT—and discuss the expected potential of the novel hybrid IVUS–OCT catheter system in the clinical field.
Collapse
Affiliation(s)
- Masafumi Ono
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.,Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Hideyuki Kawashima
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.,Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Hironori Hara
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.,Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Chao Gao
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland.,Department of Cardiology, Radboud University, Nijmegen, Netherlands.,Depatrment of Cardiology, Xijing hospital, Xi'an, China
| | - Rutao Wang
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland.,Department of Cardiology, Radboud University, Nijmegen, Netherlands.,Depatrment of Cardiology, Xijing hospital, Xi'an, China
| | - Norihiro Kogame
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Kuniaki Takahashi
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Ply Chichareon
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.,Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand
| | - Rodrigo Modolo
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.,Cardiology Division, Department of Internal Medicine, University of Campinas (UNICAMP), Campinas, Brazil
| | - Mariusz Tomaniak
- Thoraxcentre, Erasmus Medical Centre, Rotterdam, Netherlands.,First Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Joanna J Wykrzykowska
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Jan J Piek
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | | | - Brian K Courtney
- Schulich Heart Program, Sunnybrook Research Institute, University of Toronto, Toronto, ON, Canada.,Conavi Medical, North York, ON, Canada
| | - William Wijns
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Faisal Sharif
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | | | - Yoshinobu Onuma
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Patrick W Serruys
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| |
Collapse
|
2
|
Nisar H, Moore J, Piazza R, Maneas E, Chen ECS, Peters TM. A simple, realistic walled phantom for intravascular and intracardiac applications. Int J Comput Assist Radiol Surg 2020; 15:1513-1523. [PMID: 32524216 PMCID: PMC7419379 DOI: 10.1007/s11548-020-02201-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 05/18/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE This work aims to develop a simple, anatomically and haptically realistic vascular phantom, compatible with intravascular and intracardiac ultrasound. The low-cost, dual-layered phantom bridges the gap between traditional wall-only and wall-less phantoms by showing both the vessel wall and surrounding tissue in ultrasound imaging. This phantom can better assist clinical tool training, testing of intravascular devices, blood flow studies, and validation of algorithms for intravascular and intracardiac surgical systems. METHODS Polyvinyl alcohol cryogel (PVA-c) incorporating a scattering agent was used to obtain vessel and tissue-mimicking materials. Our specific design targeted the inferior vena cava and renal bifurcations which were modelled using CAD software. A custom mould and container were 3D-printed for shaping the desired vessel wall. Three phantoms were prepared by varying both the concentrations of scattering agent as well as the number of freeze-thaw cycles to which the phantom layers were subjected during the manufacturing process. Each phantom was evaluated using ultrasound imaging using the Foresight™ ICE probe. Geometrical validation was provided by comparing CAD design to a CT scan of the phantom. RESULTS The desired vascular phantom was constructed using 2.5% and 0.05% scattering agent concentration in the vessel and tissue-mimicking layers, respectively. Imaging of the three phantoms showed that increasing the number of freeze-thaw cycles did not significantly enhance the image contrast. Comparison of the US images with their CT equivalents resulted in an average error of 0.9[Formula: see text] for the lumen diameter. CONCLUSION The phantom is anatomically realistic when imaged with intracardiac ultrasound and provides a smooth lumen for the ultrasound probe and catheter to manoeuvre. The vascular phantom enables validation of intravascular and intracardiac image guidance systems. The simple construction technique also provides a workflow for designing complex, multi-layered arterial phantoms.
Collapse
Affiliation(s)
- Hareem Nisar
- Robarts Research Institute, Western University, London, Canada. .,School of Biomedical Engineering, Western University, London, Canada.
| | - John Moore
- Robarts Research Institute, Western University, London, Canada
| | - Roberta Piazza
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Efthymios Maneas
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.,Department of Medical Physics and Bioengineering, University College London, London, UK
| | - Elvis C S Chen
- Robarts Research Institute, Western University, London, Canada.,School of Biomedical Engineering, Western University, London, Canada.,Department of Medical Biophysics, Western University, London, Canada
| | - Terry M Peters
- Robarts Research Institute, Western University, London, Canada.,School of Biomedical Engineering, Western University, London, Canada.,Department of Medical Biophysics, Western University, London, Canada.,Department of Medical Imaging, Western University, London, Canada
| |
Collapse
|
3
|
Pavillard E, Sewall L. A post-market, multi-vessel evaluation of the imaging of peripheral arteries for diagnostic purposeS comparing optical Coherence tomogrApy and iNtravascular ultrasound imaging (SCAN). BMC Med Imaging 2020; 20:18. [PMID: 32059702 PMCID: PMC7023791 DOI: 10.1186/s12880-020-0420-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 01/30/2020] [Indexed: 11/29/2022] Open
Abstract
Background Intravascular imaging plays an important part in diagnosis of vascular conditions and providing insight for treatment strategy. Two main imaging modalities are intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The objective of this study was to prove non-inferiority of OCT imaging to IVUS images in matched segments of peripheral vessels in patients with suspected peripheral vascular disease. Methods The SCAN study was a prospective, non-inferiority clinical study of matched IVUS and OCT images collected along defined segments of peripheral vessels from twelve subjects (mean age 68 ± 10.3 years; 10 men) displaying symptoms of vascular disease. Luminal diameters were measured by both imaging systems at the distal, middle, and proximal points of the defined segments. Three blinded interventional radiologists evaluated the quality of both imaging modalities in identifying layered structures (3-point grading), plaque (5-point grading), calcification (5-point grading), stent structure (3-point grading), and artifacts (3-point grading) from 240 randomly ordered images. Mean grading scores and luminal diameters were calculated and analyzed with Student’s t-Test and Mann-Whitney-Wilcoxon testing. Intrareader reproducibility was calculated by intraclass correlation (ICC) analysis. Results The mean scoring of plaque, calcification, and vascular stent struts by the three readers was significant better in terms of image quality for OCT than IVUS (p < 0.001, p = 0.001, p = 0.004, respectively). The mean scores of vessel wall component visibility and artifacts generated by the two imaging systems were not significantly different (p = 0.19, p = 0.07, respectively). Mean vessel luminal diameter and area at three specific locations within the vessels were not significantly different between the two imaging modalities. No patient injury, adverse effect or device malfunction were noted during the study. Conclusions Imaging by OCT provides the physician with better visualization of some vessel and plaque chacteristics, but both IVUS and OCT imaging are safe and effective methods of examining peripheral vessels in order to perform diagnostic assessment of peripheral vessels and provide information necessary for the treatment strategy of peripheral artery disease. Trial registration NCT03480685 registered on 29 March 2018.
Collapse
Affiliation(s)
- Edward Pavillard
- Pennsylvania Vascular Institute, 420 W. Linfield-Trappe Road Suite 3200, Limerick, PA, 19468, USA.
| | - Luke Sewall
- AMITA Health, 911 N. Elm Street Suite 128, Hinsdale, IL, 60521, USA
| |
Collapse
|
4
|
Neumann EE, Young M, Erdemir A. A pragmatic approach to understand peripheral artery lumen surface stiffness due to plaque heterogeneity. Comput Methods Biomech Biomed Engin 2019; 22:396-408. [PMID: 30712373 DOI: 10.1080/10255842.2018.1560427] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The goal of this study was to develop a pragmatic approach to build patient-specific models of the peripheral artery that are aware of plaque inhomogeneity. Patient-specific models using element-specific material definition (to understand the role of plaque composition) and homogeneous material definition (to understand the role of artery diameter and thickness) were automatically built from intravascular ultrasound images of three artery segments classified with low, average, and high calcification. The element-specific material models had average surface stiffness values of 0.0735, 0.0826, and 0.0973 MPa/mm, whereas the homogeneous material models had average surface stiffness values of 0.1392, 0.1276, and 0.1922 MPa/mm for low, average, and high calcification, respectively. Localization of peak lumen stiffness and differences in patient-specific average surface stiffness for homogeneous and element-specific models suggest the role of plaque composition on surface stiffness in addition to local arterial diameter and thickness.
Collapse
Affiliation(s)
- Erica E Neumann
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA.,b Computational Biomodeling (CoBi) Core, Lerner Research Institute , Cleveland Clinic , Cleveland , OH , USA
| | - Melissa Young
- c Division of Cardiovascular Diseases , Mayo Clinic , Rochester , MN , USA
| | - Ahmet Erdemir
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA.,b Computational Biomodeling (CoBi) Core, Lerner Research Institute , Cleveland Clinic , Cleveland , OH , USA
| |
Collapse
|
5
|
Mozaffari MH, Lee WS. Freehand 3-D Ultrasound Imaging: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2099-2124. [PMID: 28716431 DOI: 10.1016/j.ultrasmedbio.2017.06.009] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 06/01/2017] [Accepted: 06/05/2017] [Indexed: 05/20/2023]
Abstract
Two-dimensional ultrasound (US) imaging has been successfully used in clinical applications as a low-cost, portable and non-invasive image modality for more than three decades. Recent advances in computer science and technology illustrate the promise of the 3-D US modality as a medical imaging technique that is comparable to other prevalent modalities and that overcomes certain drawbacks of 2-D US. This systematic review covers freehand 3-D US imaging between 1970 and 2017, highlighting the current trends in research fields, the research methods, the main limitations, the leading researchers, standard assessment criteria and clinical applications. Freehand 3-D US systems are more prevalent in the academic environment, whereas in clinical applications and industrial research, most studies have focused on 3-D US transducers and improvement of hardware performance. This topic is still an interesting active area for researchers, and there remain many unsolved problems to be addressed.
Collapse
Affiliation(s)
- Mohammad Hamed Mozaffari
- School of Electrical Engineering and Computer Science (EECS), University of Ottawa, Ottawa, Ontario, Canada.
| | - Won-Sook Lee
- School of Electrical Engineering and Computer Science (EECS), University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
6
|
Zheng S, Mengchan L. Reconstruction of coronary vessels from intravascular ultrasound image sequences based on compensation of the in-plane motion. Comput Med Imaging Graph 2013; 37:618-27. [DOI: 10.1016/j.compmedimag.2013.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2012] [Revised: 09/03/2013] [Accepted: 09/04/2013] [Indexed: 10/26/2022]
|
7
|
Doulaverakis C, Tsampoulatidis I, Antoniadis AP, Chatzizisis YS, Giannopoulos A, Kompatsiaris I, Giannoglou GD. IVUSAngio tool: a publicly available software for fast and accurate 3D reconstruction of coronary arteries. Comput Biol Med 2013; 43:1793-803. [PMID: 24209925 DOI: 10.1016/j.compbiomed.2013.08.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2013] [Revised: 07/30/2013] [Accepted: 08/18/2013] [Indexed: 11/25/2022]
Abstract
There is an ongoing research and clinical interest in the development of reliable and easily accessible software for the 3D reconstruction of coronary arteries. In this work, we present the architecture and validation of IVUSAngio Tool, an application which performs fast and accurate 3D reconstruction of the coronary arteries by using intravascular ultrasound (IVUS) and biplane angiography data. The 3D reconstruction is based on the fusion of the detected arterial boundaries in IVUS images with the 3D IVUS catheter path derived from the biplane angiography. The IVUSAngio Tool suite integrates all the intermediate processing and computational steps and provides a user-friendly interface. It also offers additional functionality, such as automatic selection of the end-diastolic IVUS images, semi-automatic and automatic IVUS segmentation, vascular morphometric measurements, graphical visualization of the 3D model and export in a format compatible with other computer-aided design applications. Our software was applied and validated in 31 human coronary arteries yielding quite promising results. Collectively, the use of IVUSAngio Tool significantly reduces the total processing time for 3D coronary reconstruction. IVUSAngio Tool is distributed as free software, publicly available to download and use.
Collapse
Affiliation(s)
- Charalampos Doulaverakis
- Information Technologies Institute, Center for Research and Technology Hellas, 6th km Charilaou-Thermi road, 57001, Thermi, Thessaloniki, Greece.
| | | | | | | | | | | | | |
Collapse
|
8
|
Rim Y, McPherson DD, Kim H. Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation. Biomed Eng Online 2013; 12:39. [PMID: 23651569 PMCID: PMC3651297 DOI: 10.1186/1475-925x-12-39] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Accepted: 04/23/2013] [Indexed: 11/13/2022] Open
Abstract
Background Intravascular ultrasound (IVUS) is a standard imaging modality for identification of plaque formation in the coronary and peripheral arteries. Volumetric three-dimensional (3D) IVUS visualization provides a powerful tool to overcome the limited comprehensive information of 2D IVUS in terms of complex spatial distribution of arterial morphology and acoustic backscatter information. Conventional 3D IVUS techniques provide sub-optimal visualization of arterial morphology or lack acoustic information concerning arterial structure due in part to low quality of image data and the use of pixel-based IVUS image reconstruction algorithms. In the present study, we describe a novel volumetric 3D IVUS reconstruction algorithm to utilize IVUS signal data and a shape-based nonlinear interpolation. Methods We developed an algorithm to convert a series of IVUS signal data into a fully volumetric 3D visualization. Intermediary slices between original 2D IVUS slices were generated utilizing the natural cubic spline interpolation to consider the nonlinearity of both vascular structure geometry and acoustic backscatter in the arterial wall. We evaluated differences in image quality between the conventional pixel-based interpolation and the shape-based nonlinear interpolation methods using both virtual vascular phantom data and in vivo IVUS data of a porcine femoral artery. Volumetric 3D IVUS images of the arterial segment reconstructed using the two interpolation methods were compared. Results In vitro validation and in vivo comparative studies with the conventional pixel-based interpolation method demonstrated more robustness of the shape-based nonlinear interpolation algorithm in determining intermediary 2D IVUS slices. Our shape-based nonlinear interpolation demonstrated improved volumetric 3D visualization of the in vivo arterial structure and more realistic acoustic backscatter distribution compared to the conventional pixel-based interpolation method. Conclusions This novel 3D IVUS visualization strategy has the potential to improve ultrasound imaging of vascular structure information, particularly atheroma determination. Improved volumetric 3D visualization with accurate acoustic backscatter information can help with ultrasound molecular imaging of atheroma component distribution.
Collapse
Affiliation(s)
- Yonghoon Rim
- Department of Internal Medicine, Division of Cardiovascular Medicine, The University of Texas Health Science Center at Houston, 6431 Fannin St, MSB 1.246, Houston, TX 77030, USA
| | | | | |
Collapse
|
9
|
|
10
|
Optical Coherence Tomography for Patient-specific 3D Artery Reconstruction and Evaluation of Wall Shear Stress in a Left Circumflex Coronary Artery. Cardiovasc Eng Technol 2011. [DOI: 10.1007/s13239-011-0047-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
11
|
Bourantas CV, Kalatzis FG, Papafaklis MI, Fotiadis DI, Tweddel AC, Kourtis IC, Katsouras CS, Michalis LK. ANGIOCARE: An automated system for fast three-dimensional coronary reconstruction by integrating angiographic and intracoronary ultrasound data. Catheter Cardiovasc Interv 2008; 72:166-75. [PMID: 18412266 DOI: 10.1002/ccd.21527] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
12
|
Modelling of image-catheter motion for 3-D IVUS. Med Image Anal 2008; 13:91-104. [PMID: 18675579 DOI: 10.1016/j.media.2008.06.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2007] [Revised: 06/13/2008] [Accepted: 06/19/2008] [Indexed: 11/23/2022]
Abstract
Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.
Collapse
|
13
|
Ehara M, Kawai M, Surmely JF, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Fujita H, Sato K, Kodama A, Katoh O, Suzuki T. Diagnostic Accuracy of Coronary In-Stent Restenosis Using 64-Slice Computed Tomography. J Am Coll Cardiol 2007; 49:951-9. [PMID: 17336718 DOI: 10.1016/j.jacc.2006.10.065] [Citation(s) in RCA: 115] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2006] [Revised: 10/23/2006] [Accepted: 10/30/2006] [Indexed: 11/15/2022]
Abstract
OBJECTIVES This study sought to evaluate the diagnostic accuracy of coronary binary in-stent restenosis (ISR) with angiography using 64-slice multislice computed tomography coronary angiography (CTCA) compared with invasive coronary angiography (ICA). BACKGROUND A noninvasive detection of ISR would result in an easier and safer way to conduct patient follow-up. METHODS We performed CTCA in 81 patients after stent implantation, and 125 stented lesions were scanned. Two sets of images were reconstructed with different types of convolution kernels. On CTCA, neointimal proliferation was visually evaluated according to luminal contrast attenuation inside the stent. Lesions were graded as follows: grade 1, none or slight neointimal proliferation; grade 2, neointimal proliferation with no significant stenosis (<50%); grade 3, neointimal proliferation with moderate stenosis (> or =50%); and grade 4, neointimal proliferation with severe stenosis (> or =75%). Grades 3 and 4 were considered binary ISR. The diagnostic accuracy of CTCA compared with ICA was evaluated. RESULTS By ICA, 24 ISRs were diagnosed. Sensitivity, specificity, positive predictive value, and negative predictive value were 92%, 81%, 54%, and 98% for the overall population, whereas values were 91%, 93%, 77%, and 98% when excluding unassessable segments (15 segments, 12%). For assessable segments, CTCA correctly diagnosed 20 of the 22 ISRs detected by ICA. Six lesions without ISR were overestimated as ISR by CTCA. As the grade of neointimal proliferation by CTCA increases, the median value of percent diameter stenosis increased linearly. CONCLUSIONS Binary ISR can be excluded with high probability by CTCA, with a moderate rate of false-positive results.
Collapse
Affiliation(s)
- Mariko Ehara
- Department of Cardiology, Toyohashi Heart Center, Toyohashi-City, Aichi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Giannoglou GD, Chatzizisis YS, Sianos G, Tsikaderis D, Matakos A, Koutkias V, Diamantopoulos P, Maglaveras N, Parcharidis GE, Louridas GE. In-vivo validation of spatially correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound and biplane angiography. Coron Artery Dis 2006; 17:533-43. [PMID: 16905966 DOI: 10.1097/00019501-200609000-00007] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The in-vivo validation of geometrically correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound and biplane coronary angiography has not been adequately investigated. The purpose of this study was to describe the reconstruction method and investigate its in-vivo feasibility and accuracy. METHODS In 17 coronary arteries (mean length, 85.7+/-17.1 mm) from nine patients, an intravascular ultrasound procedure along with a biplane coronary angiography was performed. From each angiographic projection, a single end-diastolic frame was selected in order to reconstruct the intravascular ultrasound catheter trajectory in space. In each end-diastolic intravascular ultrasound image, the lumen and media-adventitia contours were detected semi-automatically by an active contour algorithm. Each pair of contours was located on the catheter trajectory appropriately and interpolated with the adjacent pairs creating a three-dimensional volume of the arterial lumen and wall. The reconstructed lumen was back-projected onto both angiographic planes and the agreement between the back-projected and the angiographic luminal outlines was calculated. RESULTS The angiogram-derived catheter length showed very high correlation (y=0.97 x + 1.8, P<0.001) and agreement with the corresponding pullback-derived values. Accordingly, the semi-automated segmentation of intravascular ultrasound images was also in significant correlation (r> or =0.96, P<0.001) and agreement with the reference manual tracing. The back-projected luminal borders showed good overall association with the corresponding angiographic ones (r=0.78, P<0.001) as well as remarkable agreement. CONCLUSIONS Spatially correct three-dimensional reconstruction of human coronary arteries constitutes an imaging method with considerably high in-vivo feasibility and accuracy.
Collapse
Affiliation(s)
- George D Giannoglou
- Cardiovascular Engineering and Atherosclerosis Laboratory, 1st Cardiology Department, AHEPA University Hospital, Aristotle University Medical School, Thessaloniki, Greece
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
3-D fusion of biplane angiography and intravascular ultrasound for accurate visualization and volumetry. ACTA ACUST UNITED AC 2006. [DOI: 10.1007/bfb0056197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
16
|
Wahle A, Lopez JJ, Olszewski ME, Vigmostad SC, Chandran KB, Rossen JD, Sonka M. Plaque development, vessel curvature, and wall shear stress in coronary arteries assessed by X-ray angiography and intravascular ultrasound. Med Image Anal 2006; 10:615-31. [PMID: 16644262 PMCID: PMC2590653 DOI: 10.1016/j.media.2006.03.002] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2006] [Indexed: 11/22/2022]
Abstract
The relationships among vascular geometry, hemodynamics, and plaque development in the coronary arteries are complex and not yet well understood. This paper reports a methodology for the quantitative analysis of in vivo coronary morphology and hemodynamics, with particular emphasis placed on the critical issues of image segmentation and the automated classification of disease severity. We were motivated by the observation that plaque more often developed at the inner curvature of a vessel, presumably due to the relatively lower wall shear stress at these locations. The presented studies are based on our validated methodology for the three-dimensional fusion of intravascular ultrasound (IVUS) and X-ray angiography, introducing a novel approach for IVUS segmentation that incorporates a robust, knowledge-based cost function and a fully optimal, three-dimensional segmentation algorithm. Our first study shows that circumferential plaque distribution depends on local vessel curvature in the majority of vessels. The second study analyzes the correlation between plaque distribution and wall shear stress in a set of 48 in vivo vessel segments. The results were conclusive for both studies, with a stronger correlation of circumferential plaque thickness with local curvature than with wall shear stress. The inverse relationship between local wall shear stress and plaque thickness was significantly more pronounced (p<0.025) in vessel cross sections exhibiting compensatory enlargement (positive remodeling) without luminal narrowing than when the full spectrum of disease severity was considered. The inverse relationship was no longer observed in vessels where less than 35% of vessel cross sections remained without luminal narrowing. The findings of this study confirm, in vivo, the hypothesis that relatively lower wall shear stress is associated with early plaque development.
Collapse
Affiliation(s)
- Andreas Wahle
- Department of Electrical and Computer Engineering, The University of Iowa, 4016 Seamans Center, Iowa City, IA 52242, USA.
| | | | | | | | | | | | | |
Collapse
|
17
|
Guo D, Richardson P. Detection of cardiac cycle from intracoronary ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2006; 32:345-56. [PMID: 16530093 DOI: 10.1016/j.ultrasmedbio.2005.12.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2005] [Revised: 12/01/2005] [Accepted: 12/09/2005] [Indexed: 05/07/2023]
Abstract
In this paper, we describe a method automatically to determine the phase of a cardiac cycle for each video frame of an intravascular ultrasound (IVUS) video recorded in vivo. We first review the principle of IVUS video and demonstrate the general applicability of our method. We show that the pulsating heart leads to phasic changes in image content of an IVUS video. With an image processing method, we can reverse this process and reliably extract the heart-beat phase directly from IVUS video. With the phase information, we demonstrate that we can build 3-D (3D) time-variant shapes and measure lumen volume changes within a cardiac cycle. We may also measure the changes of IVUS imaging probe off-center vector within a cardiac cycle, which serves as an indicator of vessel center-line curvature. The cardiac cycle extraction algorithm requires one scan of the IVUS video frames and takes O(n) time to complete, n being the total number of the video frames. The advantage of this method is that it requires no user interaction and no hardware set-up and can be applied to coronary scans of live beating hearts. The extracted heart-beat rate, compared with clinical recordings, has less than 1% error.
Collapse
|
18
|
Bourantas CV, Kourtis IC, Plissiti ME, Fotiadis DI, Katsouras CS, Papafaklis MI, Michalis LK. A method for 3D reconstruction of coronary arteries using biplane angiography and intravascular ultrasound images. Comput Med Imaging Graph 2005; 29:597-606. [PMID: 16278063 DOI: 10.1016/j.compmedimag.2005.07.001] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2004] [Revised: 04/12/2005] [Accepted: 07/25/2005] [Indexed: 11/17/2022]
Abstract
The aim of this study is to describe a new method for the three-dimensional reconstruction of coronary arteries and its quantitative validation. Our approach is based on the fusion of the data provided by intravascular ultrasound images (IVUS) and biplane angiographies. A specific segmentation algorithm is used for the detection of the regions of interest in intravascular ultrasound images. A new methodology is also introduced for the accurate extraction of the catheter path. In detail, a cubic B-spline is used for approximating the catheter path in each biplane projection. Each B-spline curve is swept along the normal direction of its X-ray angiographic plane forming a surface. The intersection of the two surfaces is a 3D curve, which represents the reconstructed path. The detected regions of interest in the IVUS images are placed perpendicularly onto the path and their relative axial twist is computed using the sequential triangulation algorithm. Then, an efficient algorithm is applied to estimate the absolute orientation of the first IVUS frame. In order to obtain 3D visualization the commercial package Geomagic Studio 4.0 is used. The performance of the proposed method is assessed using a validation methodology which addresses the separate validation of each step followed for obtaining the coronary reconstruction. The performance of the segmentation algorithm was examined in 80 IVUS images. The reliability of the path extraction method was studied in vitro using a metal wire model and in vivo in a dataset of 11 patients. The performance of the sequential triangulation algorithm was tested in two gutter models and in the coronary arteries (marked with metal clips) of six cadaveric sheep hearts. Finally, the accuracy in the estimation of the first IVUS frame absolute orientation was examined in the same set of cadaveric sheep hearts. The obtained results demonstrate that the proposed reconstruction method is reliable and capable of depicting the morphology of coronary arteries.
Collapse
Affiliation(s)
- Christos V Bourantas
- Department of Cardiology, Medical School, University of Ioannina, GR 45110 Ioannina, Greece
| | | | | | | | | | | | | |
Collapse
|
19
|
Nadkarni SK, Boughner D, Fenster A. Image-based cardiac gating for three-dimensional intravascular ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2005; 31:53-63. [PMID: 15653231 DOI: 10.1016/j.ultrasmedbio.2004.08.025] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2003] [Revised: 08/23/2004] [Accepted: 08/31/2004] [Indexed: 05/24/2023]
Abstract
Three-dimensional (3-D) intravascular ultrasound (US), or IVUS, provides valuable insight into the tissue characteristics of the coronary wall and plaque composition. However, artefacts due to cardiac motion and vessel wall pulsation limit the accuracy and variability of coronary lumen and plaque volume measurement in 3-D IVUS images. ECG-gated image acquisition can reduce these artefacts but it requires recording the ECG signal and may increase image acquisition time. The goal of our study was to reconstruct a 3-D IVUS image with negligible cardiac motion and vessel pulsation artefacts, by developing an image-based gating method to track 2-D IVUS images over the cardiac cycle. Our approach involved selecting 2-D IVUS images belonging to the same cardiac phase from an asynchronously-acquired series, by tracking the changing lumen contour over the cardiac cycle. The algorithm was tested with IVUS images of a custom-built coronary vessel phantom and with patient images. The artefact reduction achieved using the image-gating approach was > 86% in the in vitro images and > 80% in the in vivo images in our study. Our study shows that image-based gating of IVUS images provides a useful method for accurate reconstruction of 3-D IVUS images with reduced cardiac motion artefact.
Collapse
|
20
|
Wahle A, Lopez JJ, Pennington EC, Meeks SL, Braddy KC, Fox JM, Brennan TMH, Buatti JM, Rossen JD, Sonka M. Effects of vessel geometry and catheter position on dose delivery in intracoronary brachytherapy. IEEE Trans Biomed Eng 2003; 50:1286-95. [PMID: 14619999 DOI: 10.1109/tbme.2003.818474] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In-stent restenosis is commonly observed in coronary arteries after intervention. Intravascular brachytherapy has been found effective in reducing the recurrence of restenosis after stent placement. Conventional dosing models for brachytherapy with beta (beta) radiation neglect vessel geometry as well as the position of the delivery catheter. This paper demonstrates in computer simulations on phantoms and on in vivo patient data that the estimated dose distribution varies substantially in curved vessels. In simulated phantoms of 50-mm length with a shape corresponding to a 60 degrees - 180 degrees segment of a respectively sized torus, the average dose in 2-mm depth was decreased by 2.70%-7.48% at the outer curvature and increased by 2.95%-9.70% at the inner curvature as compared with a straight phantom. In vivo data were represented in a geometrically correct three-dimensional model that was derived by fusion of intravascular ultrasound (IVUS) and biplane angiography. These data were compared with a simplified tubular model reflecting common assumptions of conventional dosing schemes. The simplified model yielded significantly lower estimates of the delivered radiation and the dose variability as compared with a geometrically correct model (p < 0.001). The estimated dose in ten vessel segments of eight patients was on average 8.76% lower at the lumen/plaque and 6.52% lower at the media/adventitia interfaces (simplified tubular model relative to geometrically correct model). The differences in dose estimates between the two models were significantly higher in the right coronary artery as compared with the left coronary artery (p < 0.001).
Collapse
Affiliation(s)
- Andreas Wahle
- Department of Electrical and Computer Engineering, 3320 Seamans Center for Engineering, University of Iowa, Iowa City, IA 52242, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Wu HC, Chen SYJ, Shroff SG, Carroll JD. Stress analysis using anatomically realistic coronary tree. Med Phys 2003; 30:2927-36. [PMID: 14655940 DOI: 10.1118/1.1593635] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Plaque rupture with superimposed thrombosis is the main cause of the acute coronary syndromes of unstable angina, myocardial infarction, and sudden death. Endothelial disruption leading to plaque rupture may relate to mechanical fatigue associated with cyclic flexion of plaques. A novel method is proposed to assess stress and strain distribution using the finite element (FE) analysis and in vivo patient-specific dynamic 3D coronary arterial tree reconstruction from cine angiographic images. The local stresses were calculated on the diseased arterial wall which was modeled as consisting of a central fibrotic cap subjected to the cyclic flexion from cardiac contraction. Various parameters characterizing the plaque were chosen including vessel diameter, percentage narrowing, and lesion length. According to the FEA simulations, the results show that the smaller vessel diameter, greater percentage narrowing, and/or larger lesion size may result in higher stress on the plaque cap, with the vessel diameter as the dominant factor.
Collapse
Affiliation(s)
- Hsien-Chih Wu
- Division of Cardiology, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262, USA
| | | | | | | |
Collapse
|
22
|
Ricciardi MJ, Meyers S, Choi K, Pang JL, Goodreau L, Davidson CJ. Angiographically silent left main disease detected by intravascular ultrasound: a marker for future adverse cardiac events. Am Heart J 2003; 146:507-12. [PMID: 12947371 DOI: 10.1016/s0002-8703(03)00239-4] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Concomitant moderate obstructive left main (LM) disease is associated with future cardiac events and poor prognosis in patients undergoing percutaneous intervention (PCI). Whether prognosis is similarly effected by LM disease not detected by angiography, but evident on intravascular ultrasound (IVUS) imaging, is not known. The purpose of this study was to evaluate the long-term prognosis of patients with angiographically insignificant LM coronary artery disease undergoing PCI. METHODS AND RESULTS One hundred and seven consecutive patients undergoing PCI with angiographically normal or mild LM disease had 2- and 3-dimensional IVUS imaging. IVUS images were digitized, and 3-dimensional reconstruction was performed. Percent diameter and area stenosis by angiography were 4.8% +/- 3.5% and 18.2% +/- 9.8%, respectively. IVUS mean luminal area and area stenosis were 17.9 +/- 5.6 mm2 and 30.2% +/- 14.7%, respectively. Long-term follow-up was available in 102 (95%) patients at a median of 29 (range 8-52) months. Major adverse cardiac events, defined as death (6), myocardial infarction (4), repeat PCI (13), or CABG (16), were associated with female sex (P =.04), diabetes (P =.02), angiographic minimum lumen diameter (P =.04), and IVUS minimum (P =.01) and mean (P =.01) lumen area. Multivariate predictors of late cardiac events were diabetes (hazard ratio 2.69, P =.014) and minimum lumen area by IVUS (hazard ratio 0.59, P =.015). CONCLUSIONS Despite being angiographically silent, LM disease detected by IVUS is an independent predictor of cardiac events and may serve as a marker for such events. These data extend the spectrum of LM disease severity and its relationship to cardiac prognosis in patients undergoing PCI.
Collapse
Affiliation(s)
- Mark J Ricciardi
- Division of Cardiology, Department of Medicine, Northwestern University Medical School, Northwestern Memorial Hospital, Chicago, Ill 60611, USA
| | | | | | | | | | | |
Collapse
|
23
|
Bourantas C, Fotiadis D, Kourtis I, Michalis L, Plissiti M. Three-dimensional coronary artery reconstruction using fusion of intravascular ultrasound and biplane angiography. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s0531-5131(03)00334-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
24
|
Chandran KB, Mun JH, Choi KK, Chen JS, Hamilton A, Nagaraj A, McPherson DD. A method for in-vivo analysis for regional arterial wall material property alterations with atherosclerosis: preliminary results. Med Eng Phys 2003; 25:289-98. [PMID: 12649013 DOI: 10.1016/s1350-4533(02)00224-2] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Atherosclerosis is a diffuse arterial disease developing over many years and resulting in a complicated three-dimensional arterial morphology. The arterial wall material properties have been demonstrated to show regional alterations with atheroma development and growth. We present a mechanical analysis of diseased arterial segments reconstructed from intravascular ultrasound images in order to quantitatively identify regional alterations in the elastic constants with atherosclerotic lesions. We employ a finite element and a displacement sensitivity analysis to divide the arterial segment into regions with different material properties and use an optimization algorithm to identify the elastic constants in these regions. The results with regional variations identified with this method correlated qualitatively with the extent and location of atherosclerotic lesions identified by visual inspection of the affected arteries. The optimized elastic modulus in regions affected by early atherosclerotic lesions ranged from 90.9 to 93.0 kPa where as the corresponding magnitudes in normal arterial segments ranged from 97.9 to 101.0 kPa. This method can be potentially employed to identify the extent and location of atherosclerotic lesions in a systematic analysis and may potentially be used for the early detection of lesion growth.
Collapse
Affiliation(s)
- K B Chandran
- Department of Biomedical Engineering, University of Iowa, 1402 SC, Iowa City, Iowa, USA
| | | | | | | | | | | | | |
Collapse
|
25
|
Klingensmith JD, Schoenhagen P, Tajaddini A, Halliburton SS, Tuzcu EM, Nissen SE, Vince DG. Automated three-dimensional assessment of coronary artery anatomy with intravascular ultrasound scanning. Am Heart J 2003; 145:795-805. [PMID: 12766735 DOI: 10.1016/s0002-8703(03)00089-9] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Angiography allows the definition of advanced, severe stages of coronary artery disease, but early atherosclerotic lesions, which do not lead to luminal stenosis, are not identified reliably. In contrast, intravascular ultrasound scanning allows the precise characterization and quantification of a wide range of atherosclerotic lesions, independent of the severity of luminal stenosis. METHODS Three-dimensional (3-D) reconstruction of entire coronary segments is possible with the integration of sequential 2-dimensional tomographic images and allows volumetric analysis of coronary arteries. RESULTS Automated systems able to recognize lumen and vessel borders and to display 3-D images are becoming available. CONCLUSION These systems have the potential for on-line 3-D image reconstruction for clinical decision-making and fast routine volumetric analysis in research studies. This review describes 3-D intravascular ultrasound scanning acquisition, analysis, and processing, and the associated technical challenges.
Collapse
Affiliation(s)
- Jon D Klingensmith
- Department of Biomedical Engineering, Lerner Research Institute, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
| | | | | | | | | | | | | |
Collapse
|
26
|
View from the Cath Lab: Topic: Intravascular ultrasound. INTERNATIONAL JOURNAL OF CARDIOVASCULAR INTERVENTIONS 2003; 1:57-63. [PMID: 12623416 DOI: 10.1080/acc.1.1.57.63] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
27
|
Stähr P, Voigtländer T, Rupprecht HJ, Aschenbrücker P, Mamtimin H, Brennecke R, Otto M, Fitzgerald PJ, Meyer J. Impact of vessel curvature on the accuracy of three-dimensional intravascular ultrasound: validation by phantoms and coronary segments. J Am Soc Echocardiogr 2002; 15:823-30. [PMID: 12174352 DOI: 10.1067/mje.2002.120700] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Three-dimensional intravascular ultrasound (IVUS) is used for volumetric assessment of arteriosclerotic plaque burden and restenotic tissue at follow-up after coronary interventions. However, the accuracy of these measurements, especially in tortuous vessels, is unclear. METHODS A commercially available electrocardiogram (ECG)-gated 3-dimensional-IVUS system was tested in volume-validated straight and curved hydrocolloid phantoms and in volume-validated coronary specimens. Catheter withdrawal (30 MHz, 3.2F) was triggered using standardized ECG source with 0.2-mm step intervals per cardiac cycle simulation. RESULTS On the basis of automated phantom volume measurements, IVUS overestimated true phantom volume (relative error = [measured V - true V]/true V x 100) by a median of 0.9%, 0.25%, and 1.96% for straight, mildly curved, and severely curved segments, respectively. The true volume of the coronary specimens was overestimated by a median of 5.79%. CONCLUSION A median percentage deviation of 3-dimensional-IVUS-measured volumes from the true volumes of less than 10% in phantoms and coronary artery segments can be achieved.
Collapse
Affiliation(s)
- Peter Stähr
- Stanford University Medical School, CA 94305, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Casserly IP, Ziada K, Kapadia S, Schoenhagen P, Tsutsui H, Karafa M, Shah A, Popovich J, Nissen SE, Tuzcu EM. Impact of nonmeasurable borders and variation in cross-section counts on intravascular ultrasound measurement of atherosclerotic plaque volume. Am J Cardiol 2002; 89:169-73. [PMID: 11792337 DOI: 10.1016/s0002-9149(01)02195-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The inability to measure borders and variation in the number of 1-mm cross sections acquired from an identical length of vessel in serial intravascular ultrasound (IVUS) pullbacks represents potential errors in calculating volumes by IVUS. In a clinical IVUS trial, the percentage of nonmeasurable lumen and external elastic membrane borders, and the percent variation in the number of 1-mm cross sections acquired from an identical vessel length at 2 separate time points, were determined. A statistical model that simulated the effect of varying the percentage of the total number of cross sections in a pullback (i.e., sample fraction) was developed using SAS software. Mean and maximum errors for calculation of atheroma volume for each sample fraction were determined. The mean percentage of nonmeasurable lumen and external elastic membrane borders in an individual patient was 8.4 +/- 8.4% and 17.4 +/- 18.4%, respectively. Mean variation in the number of 1-mm cross sections acquired in serial studies was 5.6 +/- 6.2%. A decrease in sample fraction from 95% to 50% was associated with a linear increase in the mean and maximum errors in atheroma volume, from 2.0 +/- 0.9% and 5.9 +/- 3.0%, to 7.1 +/- 2.8% and 23.4 +/- 10.3%, respectively. Thus, nonmeasurable borders and variation in the number of 1-mm cross sections acquired from an identical length of vessel in serial studies are real considerations in clinical IVUS trials. However, given the reported incidence of these considerations in this clinical trial, our statistical model suggests that the impact of each of these considerations on atheroma volume calculation is small.
Collapse
Affiliation(s)
- Ivan P Casserly
- Department of Cardiology, Barnes Jewish Hospital, St. Louis, Missouri, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Brunette J, Mongrain R, Cloutier G, Bertrand M, Bertrand OF, Tardif JC. A novel realistic three-layer phantom for intravascular ultrasound imaging. Int J Cardiovasc Imaging 2001; 17:371-81. [PMID: 12025951 DOI: 10.1023/a:1011996415966] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Intravascular ultrasound (IVUS) is an imaging modality that experienced a tremendous development over the last 20 years. Phantoms for IVUS are rare and poorly documented. The aim of this paper is to propose an original IVUS phantom that has geometries and specular textures closer to those of coronary arteries than conventional tube-like phantoms. The proposed phantom has a three-layer aspect, reproducing the intima, media and adventitia that compose the arterial wall. It is made of an agar-based compound, with water, glycerol and cellulose particles. Fourteen phantoms were quantified using IVUS. Six phantoms were evaluated by both photomacroscopy and IVUS. There was an excellent correlation between phantom dimensions evaluated by photomacroscopy and the nominal values (mold dimensions). The IVUS quantification of the phantom was closely correlated to the measurements obtained by photomacroscopy. These results demonstrate that a multilayer phantom, with known and reproducible dimensions and with realistic geometric and echographic properties has been developed.
Collapse
Affiliation(s)
- J Brunette
- Montreal Heart Institute, Quebec, Canada
| | | | | | | | | | | |
Collapse
|
30
|
Liu Y, Lai Y, Nagaraj A, Kane B, Hamilton A, Greene R, McPherson DD, Chandran KB. Pulsatile flow simulation in arterial vascular segments with intravascular ultrasound images. Med Eng Phys 2001; 23:583-95. [PMID: 11719081 DOI: 10.1016/s1350-4533(01)00088-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Previous studies have indicated a correlation between local variation in wall shear stress in arterial blood flow and atheroma development. The purpose of this study was to analyze the hemodynamics in vascular segments from morphologically realistic three-dimensional (3D) reconstruction, and to compare the computed wall shear stress in a compliant vascular segment model and the corresponding rigid walled model. Cross-sectional images of the segments of femoral and carotid arteries in five Yucatan miniswine were obtained using intravascular ultrasound (IVUS) imaging and the segment geometry was reconstructed at different times in the cardiac cycle. The actual measured wall motion from the reconstruction was employed to specify the moving boundaries for simulation of physiological distensibility. Velocity profiles and wall shear stress were computed using unsteady computational fluid dynamics analysis. The computed results revealed that the maximum wall shear stress in the compliant model was approximately 4-17 percent less than that in the rigid model if the wall motion is larger than 10 percent. Our analysis demonstrates that inaccuracies due to inflow velocity profile can be minimized by the extension of the model upstream. The phase angle between the diameter change and wall shear is affected by the local changes in geometry of the arteries. These simulations can be potentially used to analyze the effect of regional wall motion changes in the presence of atherosclerotic lesions on the local fluid dynamics and to correlate the same with subsequent growth of the lesions.
Collapse
Affiliation(s)
- Y Liu
- Department of Biomedical Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242, USA
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG. American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001; 37:1478-92. [PMID: 11300468 DOI: 10.1016/s0735-1097(01)01175-5] [Citation(s) in RCA: 1594] [Impact Index Per Article: 69.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
32
|
Schuurbiers JC, von Birgelen C, Wentzel JJ, Bom N, Serruys PW, de Feyter PJ, Slager CJ. On the IVUS plaque volume error in coronary arteries when neglecting curvature. ULTRASOUND IN MEDICINE & BIOLOGY 2000; 26:1403-1411. [PMID: 11179614 DOI: 10.1016/s0301-5629(00)00295-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Plaque volume determined by common linear 3-D IVUS analysis systems will show under- or overestimation in curved vessel segments because these systems approximate the true 3-D transducer pull-back trajectory by a straight line. We developed a mathematical model that showed that the error is primarily dependent on the curvature of the pull-back trajectory and not on vessel tortuosity. Furthermore, we measured this error in vivo in the coronary arteries of 15 patients, comparing the plaque volume using a true 3-D reconstruction method with that of the linear approach. The in vivo plaque volume error ranged from 2.3% to -1.2% for 15 coronary segments with lengths ranging from 38.8 to 89.1 mm (62.2 +/- 13 mm). The volume error introduced by linear 3-D IVUS analysis systems is dependent on the curvature of the pull-back trajectory. The error measured in vivo was small and inversely related to segment length.
Collapse
Affiliation(s)
- J C Schuurbiers
- Department of Cardiology, Thoraxcenter, University Hospital Rotterdam-Dijkzigt, Rotterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
33
|
Klingensmith JD, Shekhar R, Vince DG. Evaluation of three-dimensional segmentation algorithms for the identification of luminal and medial-adventitial borders in intravascular ultrasound images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2000; 19:996-1011. [PMID: 11131497 DOI: 10.1109/42.887615] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Intravascular ultrasound (IVUS) provides direct depiction of coronary artery anatomy, including plaque and vessel area, which is important in quantitative studies on the progression or regression of coronary artery disease. Traditionally, these studies have relied on manual evaluation, which is laborious, time consuming, and subject to large interobserver and intraobserver variability. A new technique, called active surface segmentation, alleviates these limitations and makes strides toward routine analyses. However, for three-dimensional (3-D) plaque assessment or 3-D reconstruction to become a clinical reality, methods must be developed which can analyze many images quickly. Presented is a comparison between two active surface techniques for three-dimensional segmentation of luminal and medial-adventitial borders. The force-acceleration technique and the neighborhood-search technique accurately detected both borders in vivo (r2 = 0.95 and 0.99, Williams' index = 0.67 and 0.65, and r2 = 0.95 and 0.99, WI = 0.67 and 0.70, respectively). However, the neighborhood-search technique was significantly faster and required less computation. Volume calculations for both techniques (r2 = 0.99 and r2 = 0.99) also agreed with a known-volume phantom. Active surface segmentation allows 3-D assessment of coronary morphology and further developments with this technology will provide clinical analysis tools.
Collapse
Affiliation(s)
- J D Klingensmith
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic Foundation, OH 44195, USA
| | | | | |
Collapse
|
34
|
Liu J, Miller LS, Chung CY, Overton DA, Sheera M, Forsberg F, Goldberg BB. Validation of volume measurements in esophageal pseudotumors using 3D endoluminal ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2000; 26:735-741. [PMID: 10942820 DOI: 10.1016/s0301-5629(00)00205-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The purpose of this study was to validate the accuracy and reliability of volume measurements using three-dimensional (3D) endoluminal ultrasound (ELUS) in canine pseudotumor esophageal specimens in vitro. Pseudotumors were created by injecting various volumes of US gel (0.1-1.0 ml) into canine esophageal specimens. A stepping-motor was used to pull either a 9, 12.5 or 20 MHz transducer through the lumen of the specimen at 1.5 mm/s. Images were downloaded to a LIFE computer system for 3D reconstruction. Volume measurements were made by two investigators and compared to spiral CT images. Averaging across all measurements, the average magnitude of error was 8.7% in individual US determinations and 11. 9% in CT measures. Volumes estimated from images spaced 0.5 and 1.0 mm apart, from images in the original and reconstructed planes, and from different scan frequencies, produced percentage errors that were not statistically significantly different from each other on ELUS. 3D ELUS can be used accurately and reproducibly to measure tumor volumes with a low mean percent in vitro.
Collapse
Affiliation(s)
- J Liu
- Division of Diagnostic Ultrasound, Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | |
Collapse
|
35
|
Cothren RM, Shekhar R, Tuzcu EM, Nissen SE, Cornhill JF, Vince DG. Three-dimensional reconstruction of the coronary artery wall by image fusion of intravascular ultrasound and bi-plane angiography. INTERNATIONAL JOURNAL OF CARDIAC IMAGING 2000; 16:69-85. [PMID: 10928342 DOI: 10.1023/a:1006304419505] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Intravascular ultrasound (IVUS) is becoming increasingly accepted for assessing coronary anatomy. However, its utility in visualizing and quantifying coronary morphology has been limited by its 2D tomographic nature. This study presents a 3D reconstruction technique that accurately preserves 3D geometric information. METHODS AND RESULTS Images obtained from manual IVUS pullbacks and continuous bi-plane angiography were fused, using angiography to reconstruct the transducer trajectory and aid in solving for the correct rotational orientation. A novel 3D active surface method automatically identified the luminal and medial-adventitial borders which, when superimposed on the transducer trajectory, could be surface-rendered for visualization and morphometry. Segmentation agreed well with manual assessment, and 3D luminal shape matched that of angiography when projected to 2D. CONCLUSIONS We conclude that this method provides an accurate reconstruction of the vessel's anatomy, which accounts for the true curvature of the vessel.
Collapse
Affiliation(s)
- R M Cothren
- Department of Biomedical Engineering, The Cleveland Clinic Foundation, Ohio 44195, USA
| | | | | | | | | | | |
Collapse
|
36
|
Hoffmann KR, Wahle A, Pellot-Barakat C, Sklansky J, Sonka M. Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels. INTERNATIONAL JOURNAL OF CARDIAC IMAGING 1999; 15:495-512. [PMID: 10768744 DOI: 10.1023/a:1006372704091] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The technology for determination of the 3D vascular tree and quantitative characterization of the vessel lumen and vessel wall has become available. With this technology, cardiologists will no longer rely primarily on visual inspection of coronary angiograms but use sophisticated modeling techniques combining images from various modalities for the evaluation of coronary artery disease and the effects of treatment. Techniques have been developed which allow the calculation of the imaging geometry and the 3D position of the vessel centerlines of the vascular tree from biplane views without a calibration object, i.e., from the images themselves, removing the awkwardness of moving the patient to obtain 3D information. With the geometry and positional information, techniques for reconstructing the vessel lumen can now be applied that provide more accurate estimates of the area and shape of the vessel lumen. In conjunction with these developments, techniques have been developed for combining information from intravascular ultrasound images with the information obtained from angiography. The combination of these technologies will yield a more comprehensive characterization and understanding of coronary artery disease and should lead to improved and perhaps less invasive patient care.
Collapse
Affiliation(s)
- K R Hoffmann
- Department of Neurosurgery, Toshiba Stroke Research Center, University at Buffalo, NY 14214-3025, USA.
| | | | | | | | | |
Collapse
|
37
|
Arbab-Zadeh A, DeMaria AN, Penny WF, Russo RJ, Kimura BJ, Bhargava V. Axial movement of the intravascular ultrasound probe during the cardiac cycle: implications for three-dimensional reconstruction and measurements of coronary dimensions. Am Heart J 1999; 138:865-72. [PMID: 10539817 DOI: 10.1016/s0002-8703(99)70011-6] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Motion of the intravascular ultrasound (IVUS) probe within the coronary artery from cardiac contraction may result in artifacts during 3-dimensional ultrasound image reconstruction and inaccurate measurements of coronary compliance. The purpose of this study was to establish whether longitudinal movement of the IVUS transducer in the coronary artery occurs and to quantify such motion. METHODS In 31 patients we positioned IVUS transducers at 59 coronary branch points: 41 in the left anterior descending coronary artery, 11 in the left circumflex coronary artery, and 7 in the right coronary artery. In each image sequence the branching vessel oscillated in and out of the imaging plane during the cardiac cycle, confirming longitudinal transducer movement. The extent of movement was estimated by IVUS from the dimension of the branch vessel traversed. In addition, angiographic visualization and measurement of IVUS probe motion was performed at 17 branch points in 12 patients. RESULTS Average longitudinal transducer movement as measured by IVUS was 1.50 +/- 0.80 mm (n = 46, range 0.5 to 5.5 mm). Because IVUS could not account for probe motion that exceeded the vessel branch diameter, the values obtained represent minimum movement. Average probe motion as assessed by cineangiography in a subset of 12 patients was 2.43 +/- 1.42 mm (range 0.57 to 6.56 mm). CONCLUSIONS This study establishes that longitudinal movement of IVUS transducers within coronary vessels occurs during the cardiac cycle. Because documented extent of motion may be sufficient to influence analysis, IVUS images are best obtained with electrocardiographic gating.
Collapse
Affiliation(s)
- A Arbab-Zadeh
- University of California at San Diego, Division of Cardiovascular Medicine, San Diego, CA, USA
| | | | | | | | | | | |
Collapse
|
38
|
Bruining N, Sabate M, de Feyter PJ, Kay IP, Ligthart J, Disco C, Kutryk MJ, Roelandt JR, Serruys PW. Quantitative measurements of in-stent restenosis: A comparison between quantitative coronary ultrasound and quantitative coronary angiography. Catheter Cardiovasc Interv 1999; 48:133-42. [PMID: 10506766 DOI: 10.1002/(sici)1522-726x(199910)48:2<133::aid-ccd3>3.0.co;2-h] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
While quantitative coronary angiography (QCA) remains the standard used to assess new interventional therapies, intracoronary ultrasound (ICUS) is gaining interest. The aim of the study was to determine the relationship between QCA and quantitative coronary ultrasound (QCU) measurements after stenting. Sixty-two consecutive patients with both QCA and QCU analysis after stent implantation were included in the study. The mean luminal diameter (QCU vs. QCA) were 2.74 +/- 0.46 mm and 2.41 +/- 0.49 mm (P < 0.0001), the minimal luminal diameter (MLD) 2.08 +/- 0.44 mm and 1.62 +/- 0.42 mm (P < 0. 0001), and the projected QCU MLD 1.90 +/- 0.42 mm (P < 0.0001 with respect to QCA). Percentage obstruction diameter (QCU vs. QCA) were 41.53% +/- 10.78% and 43.15% +/- 12.72% (P = NS). The stent diameter (QCU vs. QCA) were 3.54 +/- 0.65 mm and 3.80 +/- 0.37 mm (P = 0. 0004). Stent length measured by QCU were longer at 31.11 +/- 13.54 mm against 28.63 +/- 12.75 mm, P < 0.0001 with respect to QCA. In conclusion, while QCA and QCU appear to be comparable tools for measuring corrected stent diameters and stent lengths, smaller luminal diameters were found using QCA. This is of particular relevance to quantitative studies addressing absolute changes in vascular or luminal diameters. Cathet. Cardiovasc. Intervent. 48:133-142, 1999.
Collapse
Affiliation(s)
- N Bruining
- Thoraxcenter, Department of Cardiology, Erasmus Medical Center and Erasmus University, Rotterdam, The Netherlands.
| | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Wahle A, Prause PM, DeJong SC, Sonka M. Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography--methods and validation. IEEE TRANSACTIONS ON MEDICAL IMAGING 1999; 18:686-699. [PMID: 10534051 DOI: 10.1109/42.796282] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In the rapidly evolving field of intravascular ultrasound (IVUS), the assessment of vessel morphology still lacks a geometrically correct three-dimensional (3-D) reconstruction. The IVUS frames are usually stacked up to form a straight vessel, neglecting curvature and the axial twisting of the catheter during the pullback. Our method combines the information about vessel cross-sections obtained from IVUS with the information about the vessel geometry derived from biplane angiography. First, the catheter path is reconstructed from its biplane projections, resulting in a spatial model. The locations of the IVUS frames are determined and their orientations relative to each other are calculated using a discrete approximation of the Frenet-Serret formulas known from differential geometry. The absolute orientation of the frame set is established, utilizing the imaging catheter itself as an artificial landmark. The IVUS images are segmented, using our previously developed algorithm. The fusion approach has been extensively validated in computer simulations, phantoms, and cadaveric pig hearts.
Collapse
Affiliation(s)
- A Wahle
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City 52242, USA.
| | | | | | | |
Collapse
|
40
|
Abstract
The clinical use of three-dimensional (3D) ultrasound has rapidly spread to many specialities over the last ten years. The reason is easy to see, namely that single two-dimensional (2D) scans are often difficult to interpret and the mental correlation of multiple 2D scans to form a 3D image of anatomical morphology is taxing and uncertain. The rapid development of techniques for the realtime tracking of the spatial position and orientation of ultrasound probes and the development of computer graphics techniques for the presentation of anatomical images have made 3D ultrasound a realistic diagnostic tool. The authors describe the range of methods of data acquisition and display and provide illustrations of some current clinical applications.
Collapse
Affiliation(s)
- A D Linney
- Department of Medical Physics and Bioengineering, University College London, UK
| | | |
Collapse
|
41
|
Oshima A, Itchhaporia D, Fitzgerald P. New developments in intravascular ultrasound. Vasc Med 1999; 3:281-90. [PMID: 10102669 DOI: 10.1177/1358836x9800300404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Intravascular ultrasound (IVUS) is a dynamic imaging modality that provides real-time in vivo visualization of atherosclerosis and other vascular pathology. The tomographic image presentation of IVUS permits detailed assessment of plaque morphology and its corresponding responses to interventional therapy. IVUS studies have confirmed vascular remodeling in vivo, have proposed a high-pressure stent implantation strategy and have shown two key mechanisms of restenosis after angioplasty: plaque proliferation and vessel shrinkage (negative remodeling). IVUS also provides accurate quantitative information regarding lumen size, vessel size and plaque burden. These observations, essential to achieving improved outcomes, have drastically changed the understanding of atherosclerotic artery disease and interventional procedures. IVUS has matured into an essential complement to daily peripheral and coronary interventional practice and is routinely incorporated as part of the interventional arsenal in the catheterization laboratory. A variety of new imaging techniques are currently being designed and tested. These include combined therapeutic devices, further miniaturization, 3-D applications and tissue characterization. These techniques may evolve to provide increased favorable clinical outcomes and more accurate information of vessel geometry and plaque composition.
Collapse
Affiliation(s)
- A Oshima
- Center for Research in Cardiovascular Interventions, Division of Cardiovascular Medicine, Stanford University School of Medicine, CA 94305-5637, USA
| | | | | |
Collapse
|
42
|
de Vrey EA, Mintz GS, von Birgelen C, Kimura T, Noboyoshi M, Popma JJ, Serruys PW, Leon MB. Serial volumetric (three-dimensional) intravascular ultrasound analysis of restenosis after directional coronary atherectomy. J Am Coll Cardiol 1998; 32:1874-80. [PMID: 9857866 DOI: 10.1016/s0735-1097(98)00459-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES We report the use of three-dimensional (volumetric) intravascular ultrasound (IVUS) analysis to assess serial changes after directional coronary atherectomy (DCA). BACKGROUND Recent serial planar IVUS studies have described a decrease in external elastic membrane (EEM) area following catheter-based intervention as an important mechanism of late lumen renarrowing. METHODS Thirty-one patients with de novo native coronary lesions treated with DCA in the Serial Ultrasound Restenosis (SURE) Trial and in Optimal Atherectomy Restenosis Study (OARS) were enrolled in this study. Serial IVUS was performed before and after intervention and at 6 months' follow-up. In a subgroup of 18 patients from the SURE trial, IVUS was also performed at 24 h and at 1 month postintervention. Segments, 20-mm-long (200 image slices), were analyzed using a previously validated three-dimensional, computerized, automated edge-detection algorithm. The EEM, lumen, and plaque+media (P+M = EEM-lumen) volumes were calculated. RESULTS At follow-up, lumen volume was smaller than at postintervention (159+/-69 mm3 vs. 179+/-49 mm3, p = 0.0003). From postintervention to follow-up, there was a decrease in EEM volume (377+/-107 to 352+/-125 mm3, p < 0.0001), but no change in P+M volume (p = 0.52). The delta lumen volume correlated strongly with deltaEEM volume (r = 0.842, p < 0.0001), but not with deltaP+M volume. In the 18 patients from the SURE Trial, the decrease in lumen and EEM volumes occurred late, between 1 month and 6 months of follow-up. CONCLUSIONS Volumetric IVUS analysis demonstrated that late lumen volume loss following DCA was a result of a decrease in EEM volume. This was a late event, occurring between 1 and 6 months' postintervention.
Collapse
Affiliation(s)
- E A de Vrey
- Intravascular Ultrasound Imaging Laboratory, Washington Hospital Center, Washington, DC, USA
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Hammond C, Causer JP, Perry RA. Intracoronary ultrasound. Postgrad Med J 1998; 74:468-72. [PMID: 9926120 PMCID: PMC2360877 DOI: 10.1136/pgmj.74.874.468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Although contrast angiography is important in the diagnosis and treatment of atherosclerotic disease, it does have limitations. Intracoronary ultrasound more accurately assesses the amount of atherosclerosis and has given us new insights into the pathophysiology of coronary plaque accumulation and remodelling. It also allows the monitoring of therapeutic intervention. Intracoronary ultrasound is a new gold standard. It does not obviate the need for angiography but provides complementary information that enables us to perform optimal interventional procedures.
Collapse
Affiliation(s)
- C Hammond
- Cardiothoracic Centre, Liverpool, UK
| | | | | |
Collapse
|
44
|
James DG. Sir Almroth Wright, 10 August 1861. Postgrad Med J 1998. [DOI: 10.1136/pgmj.74.874.472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
45
|
Bruining N, von Birgelen C, de Feyter PJ, Ligthart J, Li W, Serruys PW, Roelandt JR. ECG-gated versus nongated three-dimensional intracoronary ultrasound analysis: implications for volumetric measurements. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1998; 43:254-60. [PMID: 9535359 DOI: 10.1002/(sici)1097-0304(199803)43:3<254::aid-ccd3>3.0.co;2-8] [Citation(s) in RCA: 80] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The quantitative analysis of a three-dimensional (3-D) intracoronary ultrasound (ICUS) image data set permits a more comprehensive assessment of coronary arterial segments. The 3-D image sets are generally acquired during continuous motorized pullbacks. However, the cyclic changes of vascular dimensions and the cyclic spatial displacement of the ICUS transducer relative to the vessel wall can result in characteristic image artifacts, which may limit the applicability of quantitative automated analysis systems. This limitation may be overcome by an ECG-gated image acquisition. In the present study we acquired in vivo (1) nongated and (2) ECG-gated 3-D ICUS image sets of 15 human atherosclerotic coronary arteries and performed a computer-assisted contour detection of the lumen and total vessel boundaries. Total vessel and lumen volumes measured significantly larger in the nongated versus ECG-gated end-diastolic image sets (753+/-307 mm3 vs. 705+/-305 mm3; 411+/-154 mm3 vs. 388+/-165 mm3, both: P < 0.05). Both end-diastolic and systolic measurements were available in nine arteries, showing a larger total vessel and lumen volume at systole (664+/-221 mm3 vs. 686+/-227 mm3, P=0.03; 384+/-164 mm3 vs. 393+/-170 mm3, P=0.08). The differences observed may be of particular interest for volumetric ICUS studies, addressing presumably small differences in vessel or lumen dimensions.
Collapse
Affiliation(s)
- N Bruining
- Thoraxcenter, Department of Cardiology, Erasmus Medical Center and Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
46
|
von Birgelen C, Mintz GS, de Vrey EA, Kimura T, Popma JJ, Airiian SG, Leon MB, Nobuyoshi M, Serruys PW, de Feyter PJ. Atherosclerotic coronary lesions with inadequate compensatory enlargement have smaller plaque and vessel volumes: observations with three dimensional intravascular ultrasound in vivo. Heart 1998; 79:137-42. [PMID: 9538305 PMCID: PMC1728616 DOI: 10.1136/hrt.79.2.137] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVE To compare vessel, lumen, and plaque volumes in atherosclerotic coronary lesions with inadequate compensatory enlargement versus lesions with adequate compensatory enlargement. DESIGN 35 angiographically significant coronary lesions were examined by intravascular ultrasound (IVUS) during motorised transducer pullback. Segments 20 mm in length were analysed using a validated automated three dimensional analysis system. IVUS was used to classify lesions as having inadequate (group I) or adequate (group II) compensatory enlargement. RESULTS There was no significant difference in quantitative angiographic measurements and the IVUS minimum lumen cross sectional area between groups I (n = 15) and II (n = 20). In group I, the vessel cross sectional area was 13.3 (3.0) mm2 at the lesion site and 14.4 (3.6) mm2 at the distal reference (p < 0.01), whereas in group II it was 17.5 (5.6) mm2 at the lesion site and 14.0 (6.0) mm2 at the distal reference (p < 0.001). Vessel and plaque cross sectional areas were significantly smaller in group I than in group II (13.3 (3.0) v 17.5 (5.6) mm2, p < 0.01; and 10.9 (2.8) v 15.2 (4.9) mm2; p < 0.005). Similarly, vessel and plaque volume were smaller in group I (291.0 (61.0) v 353.7 (110.0) mm3, and 177.5 (48.4) v 228.0 (92.8) mm3, p < 0.05 for both). Lumen areas and volumes were similar. CONCLUSIONS In lesions with inadequate compensatory enlargement, both vessel and plaque volume appear to be smaller than in lesions with adequate compensatory enlargement.
Collapse
Affiliation(s)
- C von Birgelen
- Thoraxcenter, University Hospital Rotterdam-Dijkzigt, Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
|
48
|
Dijkstra J, Wahle A, Koning G, Reiber JHC, Sonka M. Quantitative coronary ultrasound: state of the art. ACTA ACUST UNITED AC 1998. [DOI: 10.1007/978-94-011-5123-8_5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
49
|
Prause GP, DeJong SC, McKay CR, Sonka M. Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound. INTERNATIONAL JOURNAL OF CARDIAC IMAGING 1997; 13:451-62. [PMID: 9415847 DOI: 10.1023/a:1005843222820] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
At present, 3-D reconstructions of coronary vessels are generated from intravascular ultrasound (IVUS) by stacking up ECG-gated segmented IVUS frames of a pullback sequence. This simplified approach always results in straight vessel reconstructions and, therefore, gives an incorrect representation of tortuous coronary arteries. A more realistic reconstruction of tortuous vessels may be obtained by data fusion with biplane angiography. The 3-D course of the vessel is first derived from the angiograms and then combined with the segmented IVUS images. In this paper, we focus on two problems associated with the data fusion method: The definition of the pullback path and the estimation of the IVUS catheter twist during pullback. A robust algorithm for calculation of tortuosity-induced catheter twist is reported that is based on sequential triangulation of the 3-D pullback path. The method is analyzed with computer simulations and validated in helical vessel phantoms. A largely automated data fusion approach is proposed and applied to tortuous coronary arteries in cadaveric pig hearts.
Collapse
Affiliation(s)
- G P Prause
- Department of Electrical & Computer Engineering, University of Iowa, Iowa City 52242, USA.
| | | | | | | |
Collapse
|
50
|
Meier DS, Cothren RM, Vince DG, Cornhill JF. Automated morphometry of coronary arteries with digital image analysis of intravascular ultrasound. Am Heart J 1997; 133:681-90. [PMID: 9200396 DOI: 10.1016/s0002-8703(97)70170-4] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We designed and tested digital image processing strategies to perform fully automated segmentation of luminal and medial-adventitial boundaries in intravascular ultrasound images of human coronary arteries. Automated segmentation is an essential tool for advanced techniques of clinical visualization and quantitative measurement. Vascular compliance measurements and three-dimensional reconstructions are demonstrated as examples of such applications. Digital image processing was performed in three phases: (1) preprocessing, including a polar transform, local contrast enhancement, and speckle noise filtering; (2) segmentation, involving radial scanning, region growing, or cost-function minimization techniques; and (3) postprocessing, involving dropout filtering and outline smoothing. Cross-sectional areas were compared with manual tracings from experienced operators and showed good agreement. The algorithm bias ranged from -0.34 to 1.18 mm2; interclass and intraclass correlation coefficients ranged from 0.83 to 0.94. The designed techniques currently allow fully automated segmentation without operator interaction of the luminal and, if present, medial-adventitial boundary.
Collapse
Affiliation(s)
- D S Meier
- Department of Biomedical Engineering, Research Institute, The Cleveland Clinic Foundation, Ohio 44195, USA
| | | | | | | |
Collapse
|