Kewcharoen J, Shah K, Bhardwaj R, Contractor T, Turagam MK, Mandapati R, Lakkireddy D, Garg J. New-generation electronic appliances and cardiac implantable electronic devices: a systematic literature review of mechanisms and in vivo studies. J Interv Card Electrophysiol 2024; 67:1709-1720. [PMID: 38443707 DOI: 10.1007/s10840-024-01777-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 02/27/2024] [Indexed: 03/07/2024]
Abstract
INTRODUCTION Cardiac implantable electronic device (CIED) functions are susceptible to electromagnetic interference (EMI) from electromagnetic fields (EMF). Data on EMI risks from new-generation electronic appliances (EA) are limited. OBJECTIVE We performed a systematic literature review on the mechanisms of EMI, current evidence, and recently published trials evaluating the effect of EMF on CIEDs from electric vehicles (EV), smartphone, and smartwatch technology and summarize its safety data. METHODS Electronic databases, including PubMed and EMBASE, were searched for in vivo studies evaluating EMF strength and incidence between CIEDs and commercial EVs, new-generation smartphones, and new-generation smartwatches. RESULTS A total of ten studies (three on EVs, five on smartphones, one on smartphones, one on smartphones and smartwatches) were included in our systematic review. There was no report of EMI incidence associated with EVs or smartwatches. Magnet-containing smartphones (iPhone 12) can cause EMI when placed directly over CIEDs - thereby triggering the magnet mode; otherwise, no report of EMI was observed with other positions or smartphone models. CONCLUSION Current evidence suggests CIED recipients are safe from general interaction with EVs/HEVs, smartphones, and smartwatches. Strictly, results may only be applied to commercial brands or models tested in the published studies. There is limited data on EMI risk from EVs wireless charging and smartphones with MagSafe technology.
Collapse
Affiliation(s)
- Jakrin Kewcharoen
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | - Kuldeep Shah
- Division of Cardiology, Cardiac Arrhythmia Service, MercyOne Siouxland Heart and Vascular Center, Sioux City, IA, USA
| | - Rahul Bhardwaj
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | - Tahmeed Contractor
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | - Mohit K Turagam
- Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Ravi Mandapati
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | | | - Jalaj Garg
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA.
| |
Collapse
|
2
|
Stam R. New developments in cosmetic applications of electromagnetic fields: Client and occupational hazard assessment. Bioelectromagnetics 2024; 45:251-259. [PMID: 38533721 DOI: 10.1002/bem.22503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 11/14/2023] [Accepted: 02/15/2024] [Indexed: 03/28/2024]
Abstract
Energy-based devices are used to improve features of appearance for aesthetic reasons while avoiding more invasive methods. Examples of treatment targets are the reduction of wrinkles, sagging, unwanted skin lesions, body hair and excess fatty tissue, and the enhancement of muscle tissue. One treatment modality is the use of electromagnetic fields (EMF, 0‒300 GHz). The present work aims to give an up-to-date survey of cosmetic applications of EMF for professional use with an assessment of client and worker exposure and possible adverse effects. A systematic search was conducted for peer-reviewed articles (2007-2022), patents, premarket notifications, manufacturer data, and adverse effects reports. Five categories of cosmetic EMF device with increasing frequency were identified: sinusoid low frequency magnetic fields for lipolysis; pulsed low frequency magnetic fields for skin rejuvenation; pulsed low frequency magnetic fields for muscle building; radiofrequency EMF for lipolysis or skin rejuvenation; microwaves for hair removal or hyperhidrosis. In the vicinity of the last four device categories, there is a potential for exceeding the occupational exposure limits in the European Union EMF Directive, which could lead to nerve or muscle stimulation, burns or overheating. There are also potential hazards for clients or workers wearing active or passive medical devices. The severity of reported adverse effects increases with EMF frequency.
Collapse
Affiliation(s)
- Rianne Stam
- Centre for Sustainability, Environment and Health, National Institute for Public Health and the Environment, Bilthoven, The Netherlands
| |
Collapse
|
3
|
Prasertwitayakij N, Komolmis T, Gunaparn S, Pisespongsa C, Phrommintikul A, Wongcharoen W, Nantsupawat T. Electromagnetic interference from automobile passive keyless entry in cardiovascular implantable electronic devices. Expert Rev Med Devices 2023; 20:973-977. [PMID: 37668539 DOI: 10.1080/17434440.2023.2255126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 08/06/2023] [Indexed: 09/06/2023]
Abstract
INTRODUCTION The automobile passive keyless entry (PKE) system is a potential source of electromagnetic interference (EMI). We aim to determine the incidence and significance of EMI from automobile PKE system in cardiovascular implantable electronic device (CIED) patients. METHODS This was a single-center cross-sectional study conducted at Maharaj Nakorn Chiang Mai hospital, Thailand. Patients with CIED were instructed to lock and unlock two automobiles using the PKE system. Any EMI or arrhythmias were detected by CIED interrogation and single-lead electrocardiogram event recorder. We also used a spectrum analyzer to identify the automobiles working frequency bandwidth. RESULTS There was a total of 102 CIED patients. Device types included 48.0% defibrillators, 37.3% permanent pacemakers, and 14.7% cardiac resynchronization therapy device. Both interrogated data from device and event monitor revealed no incidence of EMI during the PKE activation. We failed to identify the working frequency bandwidth of the two studied cars due to very low signal strength, thus blended in with the background noise. CONCLUSIONS Automobile PKE systems transmitted very low power signals. Therefore, under normal circumstances, CIED patients can use automobile PKE system safely without any EMI regardless of key fob positions in relation to the CIED pulse generator. TRIAL REGISTRATION The study was registered at ClinicalTrials.gov (https://clinicaltrials.gov), and the identification number is NCT03016390.
Collapse
Affiliation(s)
- Narawudt Prasertwitayakij
- Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Taradol Komolmis
- Department of Electrical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai, Thailand
| | - Siriluck Gunaparn
- Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Cheeranun Pisespongsa
- Maharaj Nakorn Chiang Mai Hospital, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Arintaya Phrommintikul
- Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Wanwarang Wongcharoen
- Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Teerapat Nantsupawat
- Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
4
|
Kausar A. Nanocarbon Nanocomposites of Polyaniline and Pyrrole for Electromagnetic Interference Shielding: Design and Effectiveness. POLYM-PLAST TECH MAT 2022. [DOI: 10.1080/25740881.2022.2086816] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
Affiliation(s)
- Ayesha Kausar
- National Center for Physics, Quaid-i-Azam University Campus, Islamabad, Pakistan
| |
Collapse
|
5
|
Interference thresholds for active implantable cardiovascular devices in occupational low-frequency electric and magnetic fields: a numerical and in vitro study. Med Eng Phys 2022; 104:103799. [DOI: 10.1016/j.medengphy.2022.103799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/17/2022] [Accepted: 04/12/2022] [Indexed: 11/22/2022]
|
6
|
Driving electrochemical corrosion of implanted CoCrMo metal via oscillatory electric fields without mechanical wear. Sci Rep 2021; 11:22366. [PMID: 34785746 PMCID: PMC8595661 DOI: 10.1038/s41598-021-01810-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 11/02/2021] [Indexed: 11/08/2022] Open
Abstract
Decades of research have been dedicated to understanding the corrosion mechanisms of metal based implanted prosthetics utilized in modern surgical procedures. Focused primarily on mechanically driven wear, current fretting and crevice corrosion investigations have yet to precisely replicate the complex chemical composition of corrosion products recovered from patients' periprosthetic tissue. This work specifically targets the creation of corrosion products at the metal on metal junction utilized in modular hip prosthetics. Moreover, this manuscript serves as an initial investigation into the potential interaction between implanted CoCrMo metal alloy and low amplitude electrical oscillation, similar in magnitude to those which may develop from ambient electromagnetic radiation. It is believed that introduction of such an electrical oscillation may be able to initiate electrochemical reactions between the metal and surrounding fluid, forming the precursor to secondary wear particles, without mechanically eroding the metal's natural passivation layer. Here, we show that a low magnitude electrical oscillation (≤ 200 mV) in the megahertz frequency (106 Hz) range is capable of initiating corrosion on implanted CoCrMo without the addition of mechanical wear. Specifically, a 50 MHz, 200 mVpp sine wave generates corrosion products comprising of Cr, P, Ca, O, and C, which is consistent with previous literature on the analysis of failed hip prosthetics. These findings demonstrate that mechanical wear may not be required to initiate the production of chemically complex corrosion products.
Collapse
|
7
|
Sławiński G, Sławińska M, Usarek Z, Sobjanek M, Kempa M, Liżewska-Springer A, Lewicka E, Nowicki RJ, Raczak G. Electromagnetic Field Associated With Dermoscope Magnets May Affect the Safety of Cardiac Implanted Electronic Devices Patients. Front Cardiovasc Med 2021; 8:757032. [PMID: 34722685 PMCID: PMC8551606 DOI: 10.3389/fcvm.2021.757032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 09/17/2021] [Indexed: 12/02/2022] Open
Abstract
Dermoscopy is currently used as an auxiliary tool in general dermatology. Since some commercially available dermoscopes have built-in magnets, electromagnetic interference (EMI) may occur when examining cardiac implantable electronic devices (CIED) patients. The aim of the study was to create maps of electromagnetic fields defining a safe distance in terms of EMI. The study was performed in laboratory conditions using measuring equipment specially designed for this purpose. The following dermoscopes have been tested: Illuco IDS-1100, Visiomed Luminis, Visiomed Luminis 2, Heine NC2 with and without a contact plate, DermLite DL4, and DermLite Handyscope. Measurements were made for the following set of lift-off distances: 5, 10, 20, 30, 40, 50, and 150 mm. Each 2D scan consisted of 10-line scans shifted from each other by 10 mm. The strength of the magnetic field decreased with the distance from the faceplate. The distribution of the magnetic field differed depending on the position of the magnets. The highest magnetic field was recorded in the center of the Heine NC2 faceplate (up to 8 mT). In most cases, at a distance of 10 mm, the magnetic field strength was measured below 1 mT, with the exception of Heine NC2 and Heine NC2 with a contact plate. All tested dermoscopes generated a magnetic field of <1 mT at the distance of 20 mm. The use of dermoscopes with built-in magnets may affect the functioning of CIEDs, and the impact may vary depending on the type of dermoscope.
Collapse
Affiliation(s)
- Grzegorz Sławiński
- Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | - Martyna Sławińska
- Department of Dermatology, Venereology and Allergology, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | - Zbigniew Usarek
- Institute of Nanotechnology and Materials Science, Faculty of Applied Physics and Mathematics, Gdańsk University of Technology, Gdańsk, Poland
| | - Michał Sobjanek
- Department of Dermatology, Venereology and Allergology, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | - Maciej Kempa
- Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | | | - Ewa Lewicka
- Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | - Roman J Nowicki
- Department of Dermatology, Venereology and Allergology, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | - Grzegorz Raczak
- Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
8
|
Zink MD, Stunder D, Theiler T, Kraus T, Marx N, Napp A. In Vivo Study of Electromagnetic Interference With Cardiac Contractility Modulation Devices at Power Frequency. J Am Heart Assoc 2021; 10:e019171. [PMID: 34404231 PMCID: PMC8649288 DOI: 10.1161/jaha.120.019171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Matthias Daniel Zink
- Department of Cardiology, Angiology and Internal Intensive Care Medicine University Hospital RWTH Aachen University Aachen Germany
| | - Dominik Stunder
- Research Center for Bioelectromagnetic Interaction Institute of Occupational, Social and Environmental Medicine University Hospital RWTH Aachen University Aachen Germany
| | - Tobias Theiler
- Research Center for Bioelectromagnetic Interaction Institute of Occupational, Social and Environmental Medicine University Hospital RWTH Aachen University Aachen Germany
| | - Thomas Kraus
- Research Center for Bioelectromagnetic Interaction Institute of Occupational, Social and Environmental Medicine University Hospital RWTH Aachen University Aachen Germany
| | - Nikolaus Marx
- Department of Cardiology, Angiology and Internal Intensive Care Medicine University Hospital RWTH Aachen University Aachen Germany
| | - Andreas Napp
- Department of Cardiology, Angiology and Internal Intensive Care Medicine University Hospital RWTH Aachen University Aachen Germany
| |
Collapse
|
9
|
Huang J, Lin K, Lu W, Ding R, Wu B, Cai M, Nazarian S, Zhao W, Li J, Huang D. An in vitro Evaluation of the Effect of Transient Electromagnetic Fields on Pacemakers and Clinical Mitigation Measures. Front Cardiovasc Med 2021; 7:607604. [PMID: 33426004 PMCID: PMC7785788 DOI: 10.3389/fcvm.2020.607604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 11/25/2020] [Indexed: 11/18/2022] Open
Abstract
Background: The effect of transient electromagnetic fields on the function of pacemakers is not well-evaluated. There is a lack of effective methods for clinicians to reduce electromagnetic susceptibility (EMS) during implantation of pacemakers. This study aimed to evaluate whether a novel method of handling the excess leads in the pocket can lower the EMS of pacemakers and consequently reduce the effect of electromagnetic interference caused by transient electromagnetic fields on pacemakers. Methods: An in vitro chest model was established to simulate the clinical condition of dual-chamber pacemaker implantation. Three different intertwining patterns of excess leads were examined: parallel, twisted once, and multiple twisted-pair. Oscillated currents were injected into a copper electrical wire set horizontally above the model to create a radiated magnetic field to simulate the transient daily electromagnetic exposure of pacemakers. The electromagnetic induction of current was measured. The occurrence of EMS-related adverse events was evaluated when the induced pulsed voltage was applied. Results: Transient electromagnetic fields can induce electromagnetic noise in the pacing loop and inhibit the release of pacing pulses. The multiple twisted-pair intertwining pattern of excess leads was associated with a lower induced voltage amplitude than both the parallel and once-twisted patterns (P < 0.001). Even once twisted could significantly reduce induced voltage amplitude compared to not twisted (P < 0.001). A lower incidence of pacing inhibition was also observed in the multiple twisted-pair group than in the other two groups (P < 0.001). Conclusions: Transient electromagnetic fields can cause pacing inhibition. Twisting the excess leads for multiple turns in the pocket is an effective method to reduce the EMS of the dual-chamber pacemaker.
Collapse
Affiliation(s)
- Jing Huang
- Department of Cardiology, Shanghai East Hospital, Shanghai Tongji University School of Medicine, Shanghai, China
| | - Kaibin Lin
- Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wu Lu
- College of Electrical Engineering, Shanghai University of Electric Power, Shanghai, China
| | - Ranran Ding
- College of Electrical Engineering, Shanghai University of Electric Power, Shanghai, China
| | - Bingjie Wu
- College of Electrical Engineering, Shanghai University of Electric Power, Shanghai, China
| | - Mingqi Cai
- Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Saman Nazarian
- Section for Cardiac Electrophysiology, Department of Medicine/Cardiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, United States
| | - Wenbin Zhao
- College of Electrical Engineering, Shanghai University of Electric Power, Shanghai, China
| | - Jingbo Li
- Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Dong Huang
- Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
10
|
Driessen S, Napp A, Schmiedchen K, Kraus T, Stunder D. Electromagnetic interference in cardiac electronic implants caused by novel electrical appliances emitting electromagnetic fields in the intermediate frequency range: a systematic review. Europace 2020; 21:219-229. [PMID: 29992289 PMCID: PMC6365808 DOI: 10.1093/europace/euy155] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Accepted: 06/07/2018] [Indexed: 11/14/2022] Open
Abstract
Electromagnetic fields (EMF) in the intermediate frequency (IF) range are generated by many novel electrical appliances, including electric vehicles, radiofrequency identification systems, induction hobs, or energy supply systems, such as wireless charging systems. The aim of this systematic review is to evaluate whether cardiovascular implantable electronic devices (CIEDs) are susceptible to electromagnetic interference (EMI) in the IF range (1 kHz-1 MHz). Additionally, we discuss the advantages and disadvantages of the different types of studies used to investigate EMI. Using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, we collected and evaluated studies examining EMI in in vivo studies, in vitro studies (phantom studies, benchmark tests), and simulation studies. Our analysis revealed that cardiac implants are susceptible to malfunction induced by EMF in the IF range. Electromagnetic interference may in particular be provoked by security systems and induction hobs. The results of the studies evaluated in this systematic review further indicate that the likelihood for EMI is dependent on exposure-related parameters (field strength, frequency, and modulation) and on implant- as well as on lead-related parameters (model, type of implant, implant sensitivity setting, lead configuration, and implantation site). The review shows that the factors influencing EMI are not sufficiently characterized and EMF limit values for CIED patients cannot be derived yet. Future studies should therefore, consider exposure-related parameters as well as implant- and lead-related parameters systematically. Additionally, worst-case scenarios should be considered in all study types where possible.
Collapse
Affiliation(s)
- Sarah Driessen
- Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany
| | - Andreas Napp
- Department of Internal Medicine I (Cardiology, Angiology, Pneumology and Internal Intensive Care Medicine), University Hospital, RWTH Aachen University, Aachen, Germany
| | - Kristina Schmiedchen
- Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany
| | - Thomas Kraus
- Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany
| | - Dominik Stunder
- Research Center for Bioelectromagnetic Interaction (femu), Institute of Occupational, Social and Environmental Medicine, University Hospital, RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany
| |
Collapse
|
11
|
Lennerz C, Horlbeck L, Weigand S, Grebmer C, Blazek P, Brkic A, Semmler V, Haller B, Reents T, Hessling G, Deisenhofer I, Lienkamp M, Kolb C, O'Connor M. Patients with pacemakers or defibrillators do not need to worry about e-Cars: An observational study. Technol Health Care 2019; 28:1-12. [PMID: 31744037 DOI: 10.3233/thc-191891] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Electric cars are increasingly used for public and private transportation and represent possible sources of electromagnetic interference (EMI). Potential implications for patients with cardiac implantable electronic devices (CIED) range from unnecessary driving restrictions to life-threatening device malfunction. This prospective, cross-sectional study was designed to assess the EMI risk of electric cars on CIED function. METHODS One hundred and eight consecutive patients with CIEDs presenting for routine follow-up between May 2014 and January 2015 were enrolled in the study. The participants were exposed to electromagnetic fields generated by the four most common electric cars (Nissan Leaf, Tesla Model S, BMW i3, VW eUp) while roller-bench test-driving at Institute of Automotive Technology, Department of Mechanical Engineering, Technical University, Munich. The primary endpoint was any abnormalities in CIED function (e.g. oversensing with pacing-inhibition, inappropriate therapy or mode-switching) while driving or charging electric cars as assessed by electrocardiographic recordings and device interrogation. RESULTS No change in device function or programming was seen in this cohort which is representative of contemporary CIED devices. The largest electromagnetic field detected was along the charging cable during high current charging (116.5 μT). The field strength in the cabin was lower (2.1-3.6 μT). CONCLUSIONS Electric cars produce electromagnetic fields; however, they did not affect CIED function or programming in our cohort. Driving and charging of electric cars is likely safe for patients with CIEDs.
Collapse
Affiliation(s)
- Carsten Lennerz
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany.,German Centre for Cardiovascular Research, Partner Site Munich Heart Alliance, Munich, Germany
| | - Lorenz Horlbeck
- Institute of Automotive Technology, Department of Mechanical Engineering, Technische Universität München, Munich, Germany
| | - Severin Weigand
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany.,German Centre for Cardiovascular Research, Partner Site Munich Heart Alliance, Munich, Germany
| | - Christian Grebmer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Patrick Blazek
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Amir Brkic
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Verena Semmler
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Bernhard Haller
- Klinikum Rechts Der Isar, Institut für Medizinische Statistik und Epidemiologie, Technische Universität München, Munich, Germany
| | - Tilko Reents
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Gabriele Hessling
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Isabel Deisenhofer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Markus Lienkamp
- Institute of Automotive Technology, Department of Mechanical Engineering, Technische Universität München, Munich, Germany
| | - Christof Kolb
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Matthew O'Connor
- Wellington Hospital, Department of Cardiology, Wellington, New Zealand
| |
Collapse
|
12
|
Napp A, Kolb C, Lennerz C, Bauer W, Schulz-Menger J, Kraus T, Marx N, Stunder D. Elektromagnetische Interferenz von aktiven Herzrhythmusimplantaten im Alltag und im beruflichen Umfeld. DER KARDIOLOGE 2019. [DOI: 10.1007/s12181-019-0335-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|