1
|
Rahola JT, Mattila SM, Kiviniemi AM, Ukkola OH, Tulppo MP, Junttila MJ, Huikuri HV, Kenttä TV, Perkiömäki JS. Prognostic significance of beat-to-beat variability of spatial heterogeneity of repolarization analyzed from a 5-minute resting electrocardiogram in coronary artery disease. Heart Rhythm 2024:S1547-5271(24)00224-8. [PMID: 38597856 DOI: 10.1016/j.hrthm.2024.02.052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 02/22/2024] [Accepted: 02/22/2024] [Indexed: 04/11/2024]
Abstract
BACKGROUND Data on the prognostic significance of temporal variability of spatial heterogeneity of electrocardiographic repolarization in coronary artery disease (CAD) are limited. OBJECTIVE The purpose of this study was to evaluate the prognostic value of temporal variability of T-wave morphology analyzed from a 5-minute resting electrocardiogram in CAD. METHODS The standard deviation (SD) of T-wave morphology dispersion (TMD-SD) and the SD of total cosine R-to-T were analyzed on a beat-to-beat basis from a 5-minute period of the standard resting 12-lead electrocardiogram obtained before the clinical stress test in 1702 patients with angiographically verified CAD and well-preserved left ventricular function. RESULTS During an average of 8.7 ± 2.2 years of follow-up, 60 patients experienced sudden cardiac death/arrest (SCD/SCA) (3.5%), 69 patients nonsudden cardiac death (NSCD) (4.1%), and 161 patients noncardiac death (9.5%). TMD-SD was significantly higher in patients who experienced SCD/SCA than in other patients (1.72 ± 2.00 vs 1.12 ± 1.75; P = .01) and higher in patients who succumbed to NSCD than in other patients (1.57 ± 1.74 vs 1.12 ± 1.76; P = .04), but it did not differ significantly between patients who experienced noncardiac death and those without such an event (1.16 ± 1.42 vs 1.14 ± 1.79; P = .86). In the Cox multivariable hazards model, TMD-SD retained its significant association with the risk of SCD/SCA (hazard ratio 1.119; 95% confidence interval 1.015-1.233; P = .024) but not with the risk of NSCD (hazard ratio 1.089; 95% confidence interval 0.983-1.206; P = .103). CONCLUSION TMD-SD is independently associated with the long-term risk of SCD/SCA in patients with CAD.
Collapse
Affiliation(s)
- Janne T Rahola
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Severi M Mattila
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Antti M Kiviniemi
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Olavi H Ukkola
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Mikko P Tulppo
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - M Juhani Junttila
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Heikki V Huikuri
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Tuomas V Kenttä
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Juha S Perkiömäki
- Research Unit of Biomedicine and Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland.
| |
Collapse
|
2
|
Caldwell JL, Lee IJ, Ngo L, Wang L, Bahriz S, Xu B, Bers DM, Navedo MF, Bossuyt J, Xiang YK, Ripplinger CM. Whole-heart multiparametric optical imaging reveals sex-dependent heterogeneity in cAMP signaling and repolarization kinetics. SCIENCE ADVANCES 2023; 9:eadd5799. [PMID: 36662864 PMCID: PMC9858506 DOI: 10.1126/sciadv.add5799] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
Cyclic adenosine 3',5'-monophosphate (cAMP) is a key second messenger in cardiomyocytes responsible for transducing autonomic signals into downstream electrophysiological responses. Previous studies have shown intracellular heterogeneity and compartmentalization of cAMP signaling. However, whether cAMP signaling occurs heterogeneously throughout the intact heart and how this drives sex-dependent functional responses are unknown. Here, we developed and validated a novel cardiac-specific fluorescence resonance energy transfer-based cAMP reporter mouse and a combined voltage-cAMP whole-heart imaging system. We showed that in male hearts, cAMP was uniformly activated in response to pharmacological β-adrenergic stimulation. In contrast, female hearts showed that cAMP levels decayed faster in apical versus basal regions, which was associated with nonuniform action potential changes and notable changes in the direction of repolarization. Apical phosphodiesterase (PDE) activity was higher in female versus male hearts, and PDE inhibition prevented repolarization changes in female hearts. Thus, our imaging approach revealed sex-dependent regional breakdown of cAMP and associated electrophysiological differences.
Collapse
Affiliation(s)
| | - I-Ju Lee
- Department of Pharmacology, University of California Davis, Davis, CA, USA
| | - Lena Ngo
- Department of Pharmacology, University of California Davis, Davis, CA, USA
| | - Lianguo Wang
- Department of Pharmacology, University of California Davis, Davis, CA, USA
| | - Sherif Bahriz
- Department of Pharmacology, University of California Davis, Davis, CA, USA
- Clinical Pathology Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Bing Xu
- Department of Pharmacology, University of California Davis, Davis, CA, USA
- VA Northern California, Mather, CA, USA
| | - Donald M. Bers
- Department of Pharmacology, University of California Davis, Davis, CA, USA
| | - Manuel F. Navedo
- Department of Pharmacology, University of California Davis, Davis, CA, USA
| | - Julie Bossuyt
- Department of Pharmacology, University of California Davis, Davis, CA, USA
| | - Yang K. Xiang
- Department of Pharmacology, University of California Davis, Davis, CA, USA
- VA Northern California, Mather, CA, USA
| | | |
Collapse
|
3
|
Vondrak J, Penhaker M. Review of Processing Pathological Vectorcardiographic Records for the Detection of Heart Disease. Front Physiol 2022; 13:856590. [PMID: 36213240 PMCID: PMC9536877 DOI: 10.3389/fphys.2022.856590] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 03/04/2022] [Indexed: 11/23/2022] Open
Abstract
Vectorcardiography (VCG) is another useful method that provides us with useful spatial information about the electrical activity of the heart. The use of vectorcardiography in clinical practice is not common nowadays, mainly due to the well-established 12-lead ECG system. However, VCG leads can be derived from standard 12-lead ECG systems using mathematical transformations. These derived or directly measured VCG records have proven to be a useful tool for diagnosing various heart diseases such as myocardial infarction, ventricular hypertrophy, myocardial scars, long QT syndrome, etc., where standard ECG does not achieve reliable accuracy within automated detection. With the development of computer technology in recent years, vectorcardiography is beginning to come to the forefront again. In this review we highlight the analysis of VCG records within the extraction of functional parameters for the detection of heart disease. We focus on methods of processing VCG functionalities and their use in given pathologies. Improving or combining current or developing new advanced signal processing methods can contribute to better and earlier detection of heart disease. We also focus on the most commonly used methods to derive a VCG from 12-lead ECG.
Collapse
Affiliation(s)
- Jaroslav Vondrak
- Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, Ostrava, Czech Republic
| | | |
Collapse
|
4
|
Rahola JT, Kiviniemi AM, Ukkola OH, Tulppo MP, Junttila MJ, Huikuri HV, Kenttä TV, Perkiömäki JS. Temporal variability of T-wave morphology and risk of sudden cardiac death in patients with coronary artery disease. Ann Noninvasive Electrocardiol 2021; 26:e12830. [PMID: 33486851 PMCID: PMC8164143 DOI: 10.1111/anec.12830] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 01/04/2021] [Accepted: 01/04/2021] [Indexed: 12/16/2022] Open
Abstract
Background The possible relationship between temporal variability of electrocardiographic spatial heterogeneity of repolarization and the risk of sudden cardiac death (SCD) in patients with coronary artery disease (CAD) is not completely understood. Methods The standard deviation of T‐wave morphology dispersion (TMD‐SD), of QRST angle (QRSTA‐SD), and of T‐wave area dispersion (TW‐Ad‐SD) were analyzed on beat‐to‐beat basis from 10 min period of the baseline electrocardiographic recording in ARTEMIS study patients with angiographically verified CAD. Results After on average of 8.6 ± 2.3 years of follow‐up, a total of 66 of the 1,678 present study subjects (3.9%) had experienced SCD or were resuscitated from sudden cardiac arrest (SCA). TMD‐SD was most closely associated with the risk for SCD and was significantly higher in patients who had experienced SCD/SCA compared with those who remained alive (3.61 ± 2.83 vs. 2.64 ± 2.52, p = .008, respectively), but did not differ significantly between the patients who had experienced non‐SCD (n = 71, 4.2%) and those who remained alive (3.20 ± 2.73 vs. 2.65 ± 2.53, p = .077, respectively) or between the patients who succumbed to non‐cardiac death (n = 164, 9.8%) and those who stayed alive (2.64 ± 2.17 vs. 2.68 ± 2.58, p = .853). After adjustments with relevant clinical risk indicators of SCD/SCA, TMD‐SD still predicted SCD/SCA (HR 1.107, 95% CIs 1.035–1.185, p = .003). Conclusions Temporal variability of electrocardiographic spatial heterogeneity of repolarization represented by TMD‐SD independently predicts long‐term risk of SCD/SCA in patients with CAD.
Collapse
Affiliation(s)
- Janne T Rahola
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Antti M Kiviniemi
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Olavi H Ukkola
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Mikko P Tulppo
- Department of Physiology, Research Unit of Biomedicine, Faculty of Medicine, University of Oulu, Oulu, Finland
| | - M Juhani Junttila
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Heikki V Huikuri
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Tuomas V Kenttä
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Juha S Perkiömäki
- Research Unit of Internal Medicine, Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| |
Collapse
|
5
|
Sampedro-Puente DA, Raphel F, Fernandez-Bes J, Laguna P, Lombardi D, Pueyo E. Characterization of Spatio-Temporal Cardiac Action Potential Variability at Baseline and Under β-Adrenergic Stimulation by Combined Unscented Kalman Filter and Double Greedy Dimension Reduction. IEEE J Biomed Health Inform 2021; 25:276-288. [PMID: 32248135 DOI: 10.1109/jbhi.2020.2984647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Elevated spatio-temporal variability of human ventricular repolarization has been related to increased risk for ventricular arrhythmias and sudden cardiac death, particularly under β-adrenergic stimulation ( β-AS). This work presents a methodology for theoretical characterization of temporal and spatial repolarization variability at baseline conditions and in response to β-AS. For any measured voltage trace, the proposed methodology estimates the parameters and state variables of an underlying human ventricular action potential (AP) model by combining Double Greedy Dimension Reduction (DGDR) with automatic selection of biomarkers and the Unscented Kalman Filter (UKF). Such theoretical characterization can facilitate subsequent characterization of underlying variability mechanisms. MATERIAL AND METHODS Given an AP trace, initial estimates for the ionic conductances in a stochastic version of the baseline human ventricular O'Hara et al. model were obtained by DGDR. Those estimates served to initialize and update model parameter estimates by the UKF method based on formulation of an associated nonlinear state-space representation and joint estimation of model parameters and state variables. Similarly, β-AS-induced phosphorylation levels of cellular substrates were estimated by the DGDR-UKF methodology. Performance was tested by building an experimentally-calibrated population of virtual cells, from which synthetic AP traces were generated for baseline and β-AS conditions. RESULTS The combined DGDR-UKF methodology led to 25% reduction in the error associated with estimation of ionic current conductances at baseline conditions and phosphorylation levels under β-AS with respect to individual DGDR and UKF methods. This improvement was not at the expense of higher computational load, which was diminished by 90% with respect to the individual UKF method. Both temporal and spatial AP variability of repolarization were accurately characterized by the DGDR-UKF methodology. CONCLUSIONS A combined DGDR-UKF methodology is proposed for parameter and state variable estimation of human ventricular cell models from available AP traces at baseline and under β-AS. This methodology improves the estimation performance and reduces the convergence time with respect to individual DGDR and UKF methods and renders a suitable approach for computational characterization of spatio-temporal repolarization variability to be used for ascertainment of variability mechanisms and its relation to arrhythmogenesis.
Collapse
|
6
|
Chauhan VS, Martínez JP, van der Heyden MAG. Commentary: Increased Beat-to-Beat Variability of T-Wave Heterogeneity Measured From Standard 12-Lead Electrocardiogram Is Associated With Sudden Cardiac Death: A Case-Control Study. Front Physiol 2020; 11:598314. [PMID: 33192614 PMCID: PMC7604440 DOI: 10.3389/fphys.2020.598314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 09/08/2020] [Indexed: 11/22/2022] Open
Affiliation(s)
- Vijay S Chauhan
- Division of Cardiology, Peter Munk Cardiac Centre, University Health Network, Toronto, ON, Canada
| | - Juan Pablo Martínez
- Aragón Institute of Engineering Research, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain.,Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Zaragoza, Spain
| | - Marcel A G van der Heyden
- Division of Heart & Lungs, Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands
| |
Collapse
|
7
|
Hekkanen JJ, Kenttä TV, Haukilahti MAE, Rahola JT, Holmström L, Vähätalo J, Tulppo MP, Kiviniemi AM, Pakanen L, Ukkola OH, Junttila MJ, Huikuri HV, Perkiömäki JS. Increased Beat-to-Beat Variability of T-Wave Heterogeneity Measured From Standard 12-Lead Electrocardiogram Is Associated With Sudden Cardiac Death: A Case-Control Study. Front Physiol 2020; 11:1045. [PMID: 32982784 PMCID: PMC7477294 DOI: 10.3389/fphys.2020.01045] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 07/29/2020] [Indexed: 11/13/2022] Open
Abstract
Introduction The prognostic significance of beat-to-beat variability of spatial heterogeneity of repolarization measured from standard 12-lead ECG is not well-understood. Methods We measured the short-term variability of repolarization parameters, such as T-wave heterogeneity in leads V4–V6 (TWH) and QT interval (QT), from five consecutive beats of previously recorded standard 12-lead ECG in 200 victims of unexpected sudden cardiac death (SCD) confirmed to be due to complicated atherosclerotic coronary artery disease (CAD) in medico-legal autopsy and 200 age- and sex-matched controls with angiographically confirmed CAD. The short-term variability of repolarization heterogeneity was defined as the standard deviation (SD) of the measured repolarization parameters. All ECGs were in sinus rhythm, and no premature ventricular contractions were included in the measured segment. Results TWH-SD and QT-SD were significantly higher in SCD victims than in subjects with CAD (6.9 ± 5.6 μV vs. 3.8 ± 2.6 μV, p = 1.8E-11; 8.3 ± 13.1 ms vs. 3.8 ± 7.1 ms, p = 0.00003, respectively). After adjusting in the multivariate clinical model with factors, such as diabetes, RR interval, and beta blocker medication, TWH-SD and QT-SD retained their significant power in discriminating between the victims of SCD and the patients with CAD (p = 0.00003, p = 0.006, respectively). TWH-SD outperformed QT-SD in identifying the SCD victims among the study subjects (area under the curve in the receiver operating characteristics curve 0.730 vs. 0.679, respectively). Conclusion Increased short-term variability of repolarization heterogeneity measured from standard 12-lead ECG is associated with SCD.
Collapse
Affiliation(s)
- Jenni J Hekkanen
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Tuomas V Kenttä
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Mira Anette E Haukilahti
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Janne T Rahola
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Lauri Holmström
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Juha Vähätalo
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Mikko P Tulppo
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Antti M Kiviniemi
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Lasse Pakanen
- Forensic Medicine Unit, Finnish Institute for Health and Welfare, Oulu, Finland.,Research Unit of Internal Medicine, Department of Forensic Medicine, Medical Research Center Oulu, University of Oulu, Oulu, Finland
| | - Olavi H Ukkola
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - M Juhani Junttila
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Heikki V Huikuri
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - Juha S Perkiömäki
- Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland
| |
Collapse
|
8
|
Sampedro-Puente DA, Fernandez-Bes J, Virag L, Varro A, Pueyo E. Data-Driven Identification of Stochastic Model Parameters and State Variables: Application to the Study of Cardiac Beat-to-Beat Variability. IEEE J Biomed Health Inform 2019; 24:693-704. [PMID: 31180875 DOI: 10.1109/jbhi.2019.2921881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Enhanced spatiotemporal ventricular repolarization variability has been associated with ventricular arrhythmias and sudden cardiac death, but the involved mechanisms remain elusive. In this paper, a methodology for estimation of parameters and state variables of stochastic human ventricular cell models from input voltage data is proposed for investigation of repolarization variability. METHODS The proposed methodology formulates state-space representations based on developed stochastic cell models and uses the unscented Kalman filter to perform joint parameter and state estimation. Evaluation over synthetic and experimental data is presented. RESULTS Results on synthetically generated data show the ability of the methodology to: first, filter out measurement noise from action potential (AP) traces; second, identify model parameters and state variables from each of those individual AP traces, thus allowing robust characterization of cell-to-cell variability; and, third, replicate statistical population's distributions of input AP-based markers, including dynamic markers quantifying beat-to-beat variability. Application onto experimental data demonstrates the ability of the methodology to match input AP traces while concomitantly inferring the characteristics of underlying stochastic cell models. CONCLUSION A novel methodology is presented for estimation of parameters and hidden variables of stochastic cardiac computational models, with the advantage of providing a one-to-one match between each individual AP trace and a corresponding set of model characteristics. SIGNIFICANCE The proposed methodology can greatly help in the characterization of temporal (beat-to-beat) and spatial (cell-to-cell) variability in human ventricular repolarization and in ascertaining the corresponding underlying mechanisms, particularly in scenarios with limited available experimental data.
Collapse
|
9
|
Chen CF, Jin CL, Liu MJ, Xu YZ. Efficacy, safety, and in-hospital outcomes of subcutaneous versus transvenous implantable defibrillator therapy: A meta-analysis and systematic review. Medicine (Baltimore) 2019; 98:e15490. [PMID: 31083185 PMCID: PMC6531055 DOI: 10.1097/md.0000000000015490] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND Lead-related complication is an important drawback of trans-venous implantable cardioverter-defibrillators (TV-ICD). The subcutaneous ICD (S-ICD) was developed to overcome ICD lead associated complications; however, whether the S-ICD confers enhanced clinical benefits compared with TV-ICD remains unclear. The present systematic review and meta-analysis aimed to assess TV-ICD and S-ICD for safety, efficacy, and in-hospital outcomes in the prevention of sudden cardiac death (SCD) in patients not requiring pacing. METHODS The Medline, PubMed, EmBase, and Cochrane Library databases were searched for studies comparing TV-ICD and S-ICD. RESULTS A total of 9 eligible studies, including 5 propensity-matched case-control, 3 retrospective, and 1 cross-sectional studies were identified, assessing 7361 patients in all. Pool analyses demonstrated that SICD were associated with lower lead-related complication rates [odds ratio (OR) = 0.13; 95% confidence interval [CI] 0.05-0.33; I = 0%], and S-ICD was more beneficial in terms of reducing ICD shocks [OR = 0.48; 95% CI 0.32-0.72, I = 4%]. In addition, the patients administered S-ICD tend to have shorter length of hospital stay after implantation (SMD = -0.06; 95% CI -0.11 to 0.00, I = 0%) and reduce total complication rates (OR = 0.72; 95% CI 0.50-1.03; I = 18%), non-decreased quality of life (QoL). Moreover, both devices appeared to perform equally well with respect to infection rate and death. CONCLUSIONS Available overall data suggested that S-ICD is associated with reducing lead-related complications, ICD shocks. In addition, S-ICD has tendency to shorten hospitalization and reduce total complications, although the difference is no significant. Equivalent death rate, infection, and QoL were found between 2 groups. Therefore, S-ICD could be considered an alternative approach to TV-ICD in appropriate patients for SCD prevention.
Collapse
Affiliation(s)
- Chao-Feng Chen
- Department of Cardiology, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine
| | - Chao-Lun Jin
- Nanjing Medical University, Hangzhou, Zhejiang, China
| | - Mei-Jun Liu
- Department of Cardiology, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine
| | - Yi-Zhou Xu
- Department of Cardiology, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine
| |
Collapse
|
10
|
Sedova KA, Azarov JE, Arteyeva NV, Ovechkin AO, Vaykshnorayte MA, Vityazev VA, Bernikova OG, Shmakov DN, Kneppo P. Mechanism of electrocardiographic T-wave flattening in diabetes mellitus: experimental and simulation study. Physiol Res 2017; 66:781-789. [PMID: 28730829 DOI: 10.33549/physiolres.933494] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
In the present study we investigated the contribution of ventricular repolarization time (RT) dispersion (the maximal difference in RT) and RT gradients (the differences in RT in apicobasal, anteroposterior and interventricular directions) to T-wave flattening in a setting of experimental diabetes mellitus. In 9 healthy and 11 diabetic (alloxan model) open-chest rabbits, we measured RT in ventricular epicardial electrograms. To specify the contributions of apicobasal, interventricular and anteroposterior RT gradients and RT dispersion to the body surface potentials we determined T-wave voltage differences between modified upper- and lower-chest precordial leads (T-wave amplitude dispersions, TWAD). Expression of RT gradients and RT dispersion in the correspondent TWAD parameters was studied by computer simulations. Diabetic rabbits demonstrated flattened T-waves in precordial leads associated with increased anteroposterior and decreased apicobasal RT gradients (P<0.05) due to RT prolongation at the apex. For diabetics, simulations predicted the preserved T-vector length and altered sagittal and longitudinal TWAD proven by experimental measurements. T-wave flattening in the diabetic rabbits was not due to changes in RT dispersion, but reflected the redistributed ventricular repolarization pattern with prolonged apical repolarization resulting in increased anteroposterior and decreased apicobasal RT gradients.
Collapse
Affiliation(s)
- K A Sedova
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Kabir MM, Perez-Alday EA, Thomas J, Sedaghat G, Tereshchenko LG. Optimal configuration of adhesive ECG patches suitable for long-term monitoring of a vectorcardiogram. J Electrocardiol 2017; 50:342-348. [PMID: 28069275 PMCID: PMC5420469 DOI: 10.1016/j.jelectrocard.2016.12.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Indexed: 11/16/2022]
Abstract
The purpose of this study was to develop optimal configuration of adhesive ECG patches placement on the torso, which would provide the best agreement with the Frank orthogonal ECGs. Ten seconds of orthogonal ECG followed by 3-5min of ECGs using patches at 5 different locations simultaneously on the torso were recorded in 50 participants at rest in sitting position. Median beat was generated for each ECG and 3 patch ECGs that best correlate with orthogonal ECGs were selected for each participant. For agreement analysis, spatial QRS-T angle, spatial QRS and T vector characteristics, spatial ventricular gradient, roundness, thickness and planarity of vectorcardiographic (VCG) loops were measured. Key VCG parameters showed high agreement in Bland-Altman analysis (spatial QRS-T angle on 3-patch ECG vs. Frank ECG bias 0.3 (95% limits of agreement [-6.23;5.71 degrees]), Lin's concordance coefficient=0.996). In conclusion, newly developed orthogonal 3-patch ECG can be used for long-term VCG monitoring.
Collapse
Affiliation(s)
- Muammar M Kabir
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, USA
| | - Erick A Perez-Alday
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, USA
| | - Jason Thomas
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, USA
| | - Golriz Sedaghat
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, USA
| | - Larisa G Tereshchenko
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, USA.
| |
Collapse
|
12
|
|
13
|
Němec J. Nonalternans repolarization variability and arrhythmia – the calcium connection. J Electrocardiol 2016; 49:877-882. [DOI: 10.1016/j.jelectrocard.2016.08.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Indexed: 12/19/2022]
|
14
|
Sedaghat G, Kabir MM, Tereshchenko LG. QRS Loop Folding Phenomenon in Vectorcardiogram of Healthy Individuals. COMPUTING IN CARDIOLOGY 2016; 43:645-648. [PMID: 28944247 PMCID: PMC5606210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Recently, we developed a novel approach to study the rapid and sudden changes in the direction of ventricular activation called folding phenomenon. In order to better understand this phenomenon, we were interested in studying the variation of the orientation of [Formula: see text] for i=1…N where [Formula: see text] represents the QRS vector at the ith sample point. In this study, we described the orientation of the [Formula: see text] vector and the rotation of its frame of reference in details in 81 healthy participants from the Intercity Digital Electrocardiogram Alliance (IDEAL) study using unit quaternions and Euler angles. We observed that the variance of the elevation of rotation axis u⃗ was significantly higher in men compared to women (1340±421 vs. 1063±381, P=0.003, respectively). Additionally, there was a significant negative correlation between the variance of the azimuth of u⃗ and height (CC=-0.26, P=0.019) while the elevation of u⃗ and height were significantly positively correlated (CC=0.24, P=0.034). Moreover, the elevation of u⃗ had a positive significant correlation with weight and body surface area (CC=0.22, P=0.045 and CC=0.26, P=0.020 respectively).
Collapse
Affiliation(s)
- Golriz Sedaghat
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
- Portland State University, Portland, OR, USA
| | - Muammar M Kabir
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Larisa G Tereshchenko
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
15
|
Tereshchenko LG, Feeny A. Patient-Specific Time-Varying Association between Spatial and Temporal Variability in Repolarization and High Sensitivity Troponin I. COMPUTING IN CARDIOLOGY 2016; 43:333-336. [PMID: 28936465 PMCID: PMC5604480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
We hypothesized that the patient-specific time-varying changes in the spatial and temporal variability in cardiac repolarization (quantified by spatial TT' angle), and in myocardial injury (measured by high sensitivity troponin I, hsTnI), are independently associated with each other. Spatial TT' angle on resting 12-lead ECG (transformed to vectorcardiogram) and hsTnI were measured simultaneously every 3 hours during a 12-hour observation period in a prospective cohort of emergency department patients (n=379; age 57.8±13.2y; 54% female, 64% black), diagnosed with acute coronary syndrome (ACS; n=28), acute decompensated heart failure (ADHF; n=35), or an acute non-cardiac condition (n=316). High (above median) HsTnI in ACS was characterized by significantly larger TT' angle (12±8 vs 5±2 degrees; P=0.01) 12 hours after admission, but not earlier. In adjusted multinomial logit model, spatial TT' angle was associated with ADHF (Relative Risk Ratio 6.24 (95%CI 1.32-29.57; P=0.021), but not ACS. After full adjustment for confounders in random-effect linear regression, a 10-fold increase in hsTnI in a specific study participant was associated with 1.05 (95%CI 0.19 - 1.92) degrees increase in spatial TT' angle. Longitudinal association of hsTnI and TT' angle was especially prominent in patients with acute non-cardiac conditions, but not in ACS or ADHF.
Collapse
Affiliation(s)
- Larisa G. Tereshchenko
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, Oregon, USA
- Johns Hopkins University, Baltimore, Maryland, USA
| | - Albert Feeny
- Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
16
|
Feeny A, Tereshchenko LG. Beat-to-beat determinants of the beat-to-beat temporal and spatial variability of repolarization. J Electrocardiol 2016; 49:417-22. [PMID: 26874566 PMCID: PMC4853270 DOI: 10.1016/j.jelectrocard.2016.01.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2015] [Indexed: 11/22/2022]
Abstract
BACKGROUND The goal of this study was to compare the time series predictors of beat-to-beat variability in repolarization in healthy individuals. METHODS Spatial QRS- and T-vector amplitudes, spatial QRS-T, RR' and TT' angles, RR' and QT intervals, and QRS- and T-loop roundness were measured on 453 consecutive sinus beats in 168 healthy subjects (mean age 39.8±15.6years; 50% men; 93% white). Panel time-series regression models were adjusted by age, sex, and race. Appropriate time series of ECG metrics served as predictors and outcomes. RESULTS Increase in T-loop roundness index by 0.1 was associated with 1.1° (95%CI 0.9-2.2; P=0.048) increase in corresponding TT' angle. One unit increase in a respiration index was associated with 4ms (95%CI 0.6-7.0; P=0.021) increase in QT interval. CONCLUSIONS Spatial TT' angle and beat-to-beat variability in T-loop roundness represent intrinsic measures of repolarization variability. QT interval variability characterizes the effect of respiration and heart rate variability.
Collapse
Affiliation(s)
- Albert Feeny
- Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Larisa G Tereshchenko
- The Division of Cardiology, Department of Medicine, Johns Hopkins Hospital, Baltimore, MD, USA; The Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA.
| |
Collapse
|
17
|
Sedaghat G, Ghafoori E, Waks JW, Kabir MM, Shvilkin A, Josephson ME, Tereshchenko LG. Quantitative Assessment of Vectorcardiographic Loop Morphology. J Electrocardiol 2016; 49:154-63. [PMID: 26826894 DOI: 10.1016/j.jelectrocard.2015.12.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Indexed: 11/15/2022]
Abstract
Vectorcardiography (VCG), developed 100years ago, characterizes clinically important electrophysiological properties of the heart. In this study, VCG QRS loop roundness, planarity, thickness, rotational angle, and dihedral angle were measured in 81 healthy control subjects (39.0±14.2y; 51.8% male; 94% white), and 8 patients with infarct-cardiomyopathy and sustained monomorphic ventricular tachycardia (VT) (68.0±7.8y, 37.5% male). The angle between two consecutive QRS vectors was defined as the rotational angle, while dihedral angle quantified planar alteration over the QRS loop. In VT subjects, planarity index decreased (0.63±0.22 vs. 0.88±0.10; P=0.014), and dihedral angle was significantly more variable (variance of dihedral angle, median (IQR): 897(575-1450) vs. 542(343-773); P=0.029; rMSSD: 47.7±12.7 vs. 35.1±13.1; P=0.027). Abnormal electrophysiological substrate in VT patients is characterized by the appearance of QRS loop folding, likely due to local conduction block. The presence of fragmented QRS complexes on the 12-lead ECG had low sensitivity (31%) for detecting QRS loop folding on the VCG.
Collapse
Affiliation(s)
- Golriz Sedaghat
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR; Portland State University, Portland, OR
| | - Elyar Ghafoori
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR; University of Utah, Salt Lake City, UT
| | - Jonathan W Waks
- Division of Cardiovascular Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Muammar M Kabir
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR
| | - Alexei Shvilkin
- Division of Cardiovascular Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Mark E Josephson
- Division of Cardiovascular Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | | |
Collapse
|
18
|
Liew R. Sudden Cardiac Death Risk Stratification - An Update. Eur Cardiol 2015; 10:118-122. [PMID: 30310436 PMCID: PMC6159393 DOI: 10.15420/ecr.2015.10.2.118] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 10/28/2015] [Indexed: 11/04/2022] Open
Abstract
Sudden cardiac death (SCD) remains a major public health problem worldwide, yet current methods to identify those at greatest risk are inadequate. High-risk individuals may benefit from potentially life-saving treatment, such as insertion of an implantable-cardioverter defibrillator (ICD). However, such treatments are expensive and have their own associated risks. Furthermore, most cases of SCD occur in the general adult population who may be relatively asymptomatic but yet have an underlying predisposition to SCD. Hence, there is great interest and clinical need in improving methods for risk stratification of SCD to identify those at greatest risk and implement the most appropriate treatment. This review provides an update on current risk-stratification methods for SCD in high-risk groups, in particular patients with reduced left ventricular function following acute myocardial infarction and those with non-ischaemic dilated cardiomyopathy, and highlights some novel methods that may have a role to play in future risk-stratification schemes. Approaches and challenges for SCD risk stratification among the general public are also discussed.
Collapse
Affiliation(s)
- Reginald Liew
- Gleneagles Hospital Singapore, Duke-NUS Graduate Medical School, Singapore
| |
Collapse
|
19
|
Ghafoori E, Kabir MM, Cao J, Shvilkin A, Tereshchenko LG. Construction of intracardiac vectorcardiogram from implantable cardioverter-defibrillator intracardiac electrograms. J Electrocardiol 2015; 48:669-71. [PMID: 25987408 DOI: 10.1016/j.jelectrocard.2015.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2015] [Indexed: 11/29/2022]
Abstract
We constructed an intracardiac vectorcardiogram from 3 configurations of intracardiac cardiovertor defibrilator (ICD) electrograms (EGMs). Six distinctive 3 lead combinations were selected out of five leads: can to right ventricular coil (RVC); RVC to superior vena cava coil (SVC); atrial lead tip (A-tip) to right ventricular (RV)-ring; can to RV-ring; RV-tip to RVC, in a patient with dual chamber ICD. Surface spatial QRS-T angle (119.8°) was similar to intracardiac spatial QRS-T angle derived from ICD EGMs combination A (101.3°), B (96.1°), C (92.8°), D (95.2), E (99.0), F (96.2) and median (101.5). Future validation of the novel method is needed.
Collapse
Affiliation(s)
- Elyar Ghafoori
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, OR
| | - Muammar M Kabir
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, OR
| | | | - Alexei Shvilkin
- Division of Cardiovascular Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Larisa G Tereshchenko
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, OR.
| |
Collapse
|