Aristova M, Pang J, Ma Y, Ma L, Berhane H, Rayz V, Markl M, Schnell S. Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications. Magn Reson Med 2022; 88:1643-1658. [PMID: 35754143 PMCID: PMC9392495 DOI: 10.1002/mrm.29306] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 04/02/2022] [Accepted: 04/26/2022] [Indexed: 11/06/2022]
Abstract
Purpose Dual‐velocity encoded (dual‐venc or DV) 4D flow MRI achieves wide velocity dynamic range and velocity‐to‐noise ratio (VNR), enabling accurate neurovascular flow characterization. To reduce scan time, we present interleaved dual‐venc 4D Flow with independently prescribed, prospectively undersampled spatial resolution of the high‐venc (HV) acquisition: Variable Spatial Resolution Dual Venc (VSRDV). Methods A prototype VSRDV sequence was developed based on a Cartesian acquisition with eight‐point phase encoding, combining PEAK‐GRAPPA acceleration with zero‐filling in phase and partition directions for HV. The VSRDV approach was optimized by varying z, the zero‐filling fraction of HV relative to low‐venc, between 0%–80% in vitro (realistic neurovascular model with pulsatile flow) and in vivo (n = 10 volunteers). Antialiasing precision, mean and peak velocity quantification accuracy, and test–retest reproducibility were assessed relative to reference images with equal‐resolution HV and low venc (z = 0%). Results In vitro results for all z demonstrated an antialiasing true positive rate at least 95% for RPEAK−GRAPPA = 2 and 5, with no linear relationship to z (p = 0.62 and 0.13, respectively). Bland–Altman analysis for z = 20%, 40%, 60%, or 80% versus z = 0% in vitro and in vivo demonstrated no bias >1% of venc in mean or peak velocity values at any RZF. In vitro mean and peak velocity, and in vivo peak velocity, had limits of agreement within 15%. Conclusion VSRDV allows up to 34.8% scan time reduction compared to PEAK‐GRAPPA accelerated DV 4D Flow MRI, enabling large spatial coverage and dynamic range while maintaining VNR and velocity measurement accuracy. Click here for author‐reader discussions
Collapse
Affiliation(s)
- Maria Aristova
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Jianing Pang
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,MR R&D and Collaborations, Siemens Medical Solutions USA Inc., Chicago, IL, USA
| | - Yue Ma
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Liliana Ma
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Haben Berhane
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University McCormick School of Engineering, Evanston, Illinois, USA
| | - Vitaliy Rayz
- Weldon School of Biomedical Engineering, Purdue University College of Engineering, West Lafayette, Indiana, USA
| | - Michael Markl
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University McCormick School of Engineering, Evanston, Illinois, USA
| | - Susanne Schnell
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Institut für Physik, Universität Greifswald, Greifswald, Germany
| |
Collapse
|