1
|
Decker JH, Mazal AT, Bui A, Sprenger T, Skare S, Fischbein N, Zaharchuk G. NeuroMix with MRA: A Fast MR Protocol to Reduce Head and Neck CTA for Patients with Acute Neurologic Presentations. AJNR Am J Neuroradiol 2024; 45:1730-1736. [PMID: 38906674 PMCID: PMC11543087 DOI: 10.3174/ajnr.a8386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Accepted: 06/11/2024] [Indexed: 06/23/2024]
Abstract
BACKGROUND AND PURPOSE Overuse of CT-based cerebrovascular imaging in the emergency department and inpatient settings, notably CTA of the head and neck for minor and nonfocal neurologic presentations, stresses imaging services and exposes patients to radiation and contrast. Furthermore, such CT-based imaging is often insufficient for definitive diagnosis, necessitating additional MR imaging. Recent advances in fast MRI may allow timely assessment and a reduced need for head and neck CTA in select populations. MATERIALS AND METHODS We identified inpatients or patients in the emergency department who underwent CTAHN (including noncontrast and postcontrast head CT, with or without CTP imaging) followed within 24 hours by a 3T MRI study that included a 2.5-minute unenhanced multicontrast sequence (NeuroMix) and a 5-minute intracranial time of flight MRA) during a 9-month period (April to December 2022). Cases were classified by 4 radiologists in consensus as to whether NeuroMix and NeuroMix + MRA detected equivalent findings, detected unique findings, or missed findings relative to CTAHN. RESULTS One hundred seventy-four cases (mean age, 67 [SD, 16] years; 56% female) met the inclusion criteria. NeuroMix alone and NeuroMix + MRA protocols were determined to be equivalent or better compared with CTAHN in 71% and 95% of patients, respectively. NeuroMix always provided equivalent or better assessment of the brain parenchyma, with unique findings on NeuroMix and NeuroMix + MRA in 35% and 36% of cases, respectively, most commonly acute infarction or multiple microhemorrhages. In 8/174 cases (5%), CTAHN identified vascular abnormalities not seen on the NeuroMix + MRA protocol due to the wider coverage of the cervical arteries by CTAHN. CONCLUSIONS A fast MR imaging protocol consisting of NeuroMix + MRA provided equivalent or better information compared with CTAHN in 95% of cases in our population of patients with an acute neurologic presentation. The findings provide a deeper understanding of the benefits and challenges of a fast unenhanced MR-first approach with NeuroMix + MRA, which could be used to design prospective trials in select patient groups, with the potential to reduce radiation dose, mitigate adverse contrast-related patient and environmental effects, and lessen the burden on radiologists and health care systems.
Collapse
Affiliation(s)
- Johannes H Decker
- From the Division of Neuroimaging and Neurointervention (J.H.D., A.T.M., A.B., N.F., G.Z.), Department of Radiology, Stanford University, Stanford, California
| | - Alexander T Mazal
- From the Division of Neuroimaging and Neurointervention (J.H.D., A.T.M., A.B., N.F., G.Z.), Department of Radiology, Stanford University, Stanford, California
| | - Amy Bui
- From the Division of Neuroimaging and Neurointervention (J.H.D., A.T.M., A.B., N.F., G.Z.), Department of Radiology, Stanford University, Stanford, California
| | - Tim Sprenger
- MR Applied Science Laboratory Europe (T.S.), GE Healthcare, Stockholm, Sweden
- Department of Clinical Neuroscience (T.S., S.S.), Karolinska Institutet, Stockholm, Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience (T.S., S.S.), Karolinska Institutet, Stockholm, Sweden
| | - Nancy Fischbein
- From the Division of Neuroimaging and Neurointervention (J.H.D., A.T.M., A.B., N.F., G.Z.), Department of Radiology, Stanford University, Stanford, California
| | - Greg Zaharchuk
- From the Division of Neuroimaging and Neurointervention (J.H.D., A.T.M., A.B., N.F., G.Z.), Department of Radiology, Stanford University, Stanford, California
| |
Collapse
|
2
|
Li H, Li Z, Xia J, Shen L, Duan G, Wang Z. A retrospective analysis of a newly proposed imaging-etiologic classification for acute ischemic stroke with large vascular occlusion based on MRI and pathogenesis. PeerJ 2024; 12:e18342. [PMID: 39465175 PMCID: PMC11512804 DOI: 10.7717/peerj.18342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Accepted: 09/26/2024] [Indexed: 10/29/2024] Open
Abstract
Background Endovascular treatment (EVT) has emerged as the preferred initial therapeutic option for acute ischemic stroke (AIS) with large vascular occlusion (LVO). To facilitate more targeted EVT interventions, we propose a novel imaging-etiologic classification system derived from a comprehensive analysis of preoperative MRI and pathogenesis in AIS patients. Methods From June 2020 to December 2021, a retrospective analysis was conducted on 184 consecutive AIS patients who underwent preoperative MRI and subsequent EVT at the Henan Provincial Cerebrovascular Hospital Stroke Center. Patients' medical histories were comprehensively reviewed. According to MRI, anterior circulation infarction (ACI) and posterior circulation infarction (PCI) were divided into four groups respectively (A-D & a-d). Three types (1-3) of etiology were identified based on pathogenesis. The types were respectively evaluated by screening test with intra-operative finding of EVT. Results Our imaging-etiologic classification achieved an overall positive rate of 90.2% (166/184) when compared to the gold standard. The screening test for each type demonstrated excellent validity (Youden's index ≥ 0.75) and reliability (Kappa ≥ 0.80). Conclusion The imaging-etiologic classification represents a simple yet comprehensive approach that can be readily applied in the management of AIS with LVO. It can rapidly and effectively locate the vascular occlusion, and reveal the pathogenesis.
Collapse
Affiliation(s)
- Hao Li
- Department of Cerebrovascular Disease, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, Henan, China
| | - Zhaoshuo Li
- Department of Cerebrovascular Disease, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, Henan, China
| | - Jinchao Xia
- Department of Cerebrovascular Disease, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, Henan, China
| | - Lijun Shen
- Department of Clinical Medical Research Center, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, Henan, China
| | - Guangming Duan
- Department of Cerebrovascular Disease, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, Henan, China
| | - Ziliang Wang
- Department of Cerebrovascular Disease, Zhengzhou University People’s Hospital & Henan Provincial People’s Hospital, Zhengzhou, Henan, China
| |
Collapse
|
3
|
Tu LH, Tegtmeyer K, de Oliveira Santo ID, Venkatesh AK, Forman HP, Mahajan A, Melnick ER. Abbreviated MRI in the evaluation of dizziness: report turnaround times and impact on length of stay compared to CT, CTA, and conventional MRI. Emerg Radiol 2024; 31:705-711. [PMID: 39034381 DOI: 10.1007/s10140-024-02273-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Accepted: 07/16/2024] [Indexed: 07/23/2024]
Abstract
PURPOSE Neuroimaging is often used in the emergency department (ED) to evaluate for posterior circulation strokes in patients with dizziness, commonly with CT/CTA due to speed and availability. Although MRI offers more sensitive evaluation, it is less commonly used, in part due to slower turnaround times. We assess the potential for abbreviated MRI to improve reporting times and impact on length of stay (LOS) compared to conventional MRI (as well as CT/CTA) in the evaluation of acute dizziness. MATERIALS AND METHODS We performed a retrospective analysis of length of stay via LASSO regression for patients presenting to the ED with dizziness and discharged directly from the ED over 4 years (1/1/2018-12/31/2021), controlling for numerous patient-level and logistical factors. We additionally assessed turnaround time between order and final report for various imaging modalities. RESULTS 14,204 patients were included in our analysis. Turnaround time for abbreviated MRI was significantly lower than for conventional MRI (4.40 h vs. 6.14 h, p < 0.001) with decreased impact on LOS (0.58 h vs. 2.02 h). Abbreviated MRI studies had longer turnaround time (4.40 h vs. 1.41 h, p < 0.001) and was associated with greater impact on ED LOS than non-contrast CT head (0.58 h vs. 0.00 h), however there was no significant difference in turnaround time compared to CTA head and neck (4.40 h vs. 3.86 h, p = 0.06) with similar effect on LOS (0.58 h vs. 0.53 h). Ordering both CTA and conventional MRI was associated with a greater-than-linear increase in LOS (additional 0.37 h); the same trend was not seen combining CTA and abbreviated MRI (additional 0.00 h). CONCLUSIONS In the acute settings where MRI is available, abbreviated MRI protocols may improve turnaround times and LOS compared to conventional MRI protocols. Since recent guidelines recommend MRI over CT in the evaluation of dizziness, implementation of abbreviated MRI protocols has the potential to facilitate rapid access to preferred imaging, while minimizing impact on ED workflows.
Collapse
Affiliation(s)
- Long H Tu
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Tompkins East 2, New Haven, CT 06520, USA.
| | - Kyle Tegtmeyer
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Tompkins East 2, New Haven, CT 06520, USA
| | - Irene Dixe de Oliveira Santo
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Tompkins East 2, New Haven, CT 06520, USA
| | - Arjun K Venkatesh
- Department of Emergency Medicine, Yale School of Medicine, 464 Congress Ave # 260, New Haven, CT 06519, USA
| | - Howard P Forman
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Tompkins East 2, New Haven, CT 06520, USA
| | - Amit Mahajan
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Tompkins East 2, New Haven, CT 06520, USA
| | - Edward R Melnick
- Department of Emergency Medicine, Yale School of Medicine, 464 Congress Ave # 260, New Haven, CT 06519, USA
| |
Collapse
|
4
|
Qu H, Tang H, Gao DY, Li YX, Zhao Y, Ban QQ, Chen YC, Lu L, Wang W. Target-based deep learning network surveillance of non-contrast computed tomography for small infarct core of acute ischemic stroke. Front Neurol 2024; 15:1477811. [PMID: 39364421 PMCID: PMC11447964 DOI: 10.3389/fneur.2024.1477811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Accepted: 09/09/2024] [Indexed: 10/05/2024] Open
Abstract
Purpose Rapid diagnosis of acute ischemic stroke (AIS) is critical to achieve positive outcomes and prognosis. This study aimed to construct a model to automatically identify the infarct core based on non-contrast-enhanced CT images, especially for small infarcts. Methods The baseline CT scans of AIS patients, who had DWI scans obtained within less than 2 h apart, were included in this retrospective study. A modified Target-based deep learning model of YOLOv5 was developed to detect infarctions on CT. Randomly selected CT images were used for testing and evaluated by neuroradiologists and the model, using the DWI as a reference standard. Intraclass correlation coefficient (ICC) and weighted kappa were calculated to assess the agreement. The paired chi-square test was used to compare the diagnostic efficacy of physician groups and automated models in subregions. p < 0.05 was considered statistically significant. Results Five hundred and eighty four AIS patients were enrolled in total, finally 275 cases were eligible. Modified YOLOv5 perform better with increased precision (0.82), recall (0.81) and mean average precision (0.79) than original YOLOv5. Model showed higher consistency to the DWI-ASPECTS scores (ICC = 0.669, κ = 0.447) than neuroradiologists (ICC = 0.452, κ = 0.247). The sensitivity (75.86% vs. 63.79%), specificity (98.87% vs. 95.02%), and accuracy (96.20% vs. 91.40%) were better than neuroradiologists. Automatic model had better diagnostic efficacy than physician diagnosis in the M6 region (p = 0.039). Conclusion The deep learning model was able to detect small infarct core on CT images more accurately. It provided the infarct portion and extent, which is valuable in assessing the severity of disease and guiding treatment procedures.
Collapse
Affiliation(s)
- Hang Qu
- Department of Radiology, Affiliated Hospital of Yangzhou University, Yangzhou, Jiangsu Province, China
| | - Hui Tang
- Department of Health Science and Kinesiology, Georgia Southern University, Statesboro, GA, United States
| | - Dong-yang Gao
- School of Computer Science and Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu Province, China
| | - Yong-xin Li
- Chinese Institute of Brain Research, Beijing, China
| | - Yi Zhao
- Department of Radiology, Affiliated Hospital of Yangzhou University, Yangzhou, Jiangsu Province, China
| | - Qi-qi Ban
- Department of Radiology, Affiliated Hospital of Yangzhou University, Yangzhou, Jiangsu Province, China
| | - Yu-Chen Chen
- Department of Radiology, Nanjing Medical University Affiliated First Hospital, Nanjing, China
| | - Lu Lu
- Department of Radiology, Affiliated Hospital of Yangzhou University, Yangzhou, Jiangsu Province, China
| | - Wei Wang
- Department of Radiology, Affiliated Hospital of Yangzhou University, Yangzhou, Jiangsu Province, China
| |
Collapse
|
5
|
Aamand R, Rasmussen PM, Andersen KS, de Paoli S, Weitzberg E, Christiansen M, Lund TE, Østergaard L. Cerebral microvascular changes in healthy carriers of the APOE-ɛ4 Alzheimer's disease risk gene. PNAS NEXUS 2024; 3:pgae369. [PMID: 39253395 PMCID: PMC11382292 DOI: 10.1093/pnasnexus/pgae369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Accepted: 08/13/2024] [Indexed: 09/11/2024]
Abstract
APOE-ɛ4 is a genetic risk factor for Alzheimer's disease (AD). AD is associated with reduced cerebral blood flow (CBF) and with microvascular changes that limit the transport of oxygen from blood into brain tissue: reduced microvascular cerebral blood volume and high relative transit time heterogeneity (RTH). Healthy APOE-ɛ4 carriers reveal brain regions with elevated CBF compared with carriers of the common ɛ3 allele. Such asymptomatic hyperemia may reflect microvascular dysfunction: a vascular disease entity characterized by suboptimal tissue oxygen uptake, rather than limited blood flow per se. Here, we used perfusion MRI to show that elevated regional CBF is accompanied by reduced capillary blood volume in healthy APOE-ɛ4 carriers (carriers) aged 30-70 years compared with similarly aged APOE-ɛ3 carriers (noncarriers). Younger carriers have elevated hippocampal RTH and more extreme RTH values throughout both white matter (WM) and cortical gray matter (GM) compared with noncarriers. Older carriers have reduced WM CBF and more extreme GM RTH values than noncarriers. Across all groups, lower WM and hippocampal RTH correlate with higher educational attainment, which is associated with lower AD risk. Three days of dietary nitrate supplementation increased carriers' WM CBF but caused older carriers to score worse on two of six aggregate neuropsychological scores. The intervention improved late recall in younger carriers and in noncarriers. The APOE-ɛ4 gene is associated with microvascular changes that may impair tissue oxygen extraction. We speculate that vascular risk factor control is particularly important for APOE-ɛ4 carriers' healthy aging.
Collapse
Affiliation(s)
- Rasmus Aamand
- Department of Clinical Medicine, Center of Functionally Integrative Neuroscience (CFIN), Aarhus University, 8000 Aarhus, Denmark
| | - Peter M Rasmussen
- Department of Clinical Medicine, Center of Functionally Integrative Neuroscience (CFIN), Aarhus University, 8000 Aarhus, Denmark
| | - Katrine Schilling Andersen
- Department of Clinical Medicine, Center of Functionally Integrative Neuroscience (CFIN), Aarhus University, 8000 Aarhus, Denmark
| | - Stine de Paoli
- Department of Clinical Medicine, Center of Functionally Integrative Neuroscience (CFIN), Aarhus University, 8000 Aarhus, Denmark
| | - Eddie Weitzberg
- Department of Physiology and Pharmacology, Karolinska Institutet, 17177 Stockholm, Sweden
- Department of Perioperative Medicine and Intensive Care, Karolinska University Hospital, 17177 Stockholm, Sweden
| | - Michael Christiansen
- Department for Congenital Disorders, Statens Serum Institut, 2300 Copenhagen, Denmark
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Torben E Lund
- Department of Clinical Medicine, Center of Functionally Integrative Neuroscience (CFIN), Aarhus University, 8000 Aarhus, Denmark
| | - Leif Østergaard
- Department of Clinical Medicine, Center of Functionally Integrative Neuroscience (CFIN), Aarhus University, 8000 Aarhus, Denmark
- Department of Neuroradiology, Aarhus University Hospital, 8200 Aarhus, Denmark
| |
Collapse
|
6
|
Schuhholz M, Ruff C, Bürkle E, Feiweier T, Clifford B, Kowarik M, Bender B. Ultrafast Brain MRI at 3 T for MS: Evaluation of a 51-Second Deep Learning-Enhanced T2-EPI-FLAIR Sequence. Diagnostics (Basel) 2024; 14:1841. [PMID: 39272626 PMCID: PMC11393910 DOI: 10.3390/diagnostics14171841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Revised: 08/18/2024] [Accepted: 08/20/2024] [Indexed: 09/15/2024] Open
Abstract
In neuroimaging, there is no equivalent alternative to magnetic resonance imaging (MRI). However, image acquisitions are generally time-consuming, which may limit utilization in some cases, e.g., in patients who cannot remain motionless for long or suffer from claustrophobia, or in the event of extensive waiting times. For multiple sclerosis (MS) patients, MRI plays a major role in drug therapy decision-making. The purpose of this study was to evaluate whether an ultrafast, T2-weighted (T2w), deep learning-enhanced (DL), echo-planar-imaging-based (EPI) fluid-attenuated inversion recovery (FLAIR) sequence (FLAIRUF) that has targeted neurological emergencies so far might even be an option to detect MS lesions of the brain compared to conventional FLAIR sequences. Therefore, 17 MS patients were enrolled prospectively in this exploratory study. Standard MRI protocols and ultrafast acquisitions were conducted at 3 tesla (T), including three-dimensional (3D)-FLAIR, turbo/fast spin-echo (TSE)-FLAIR, and FLAIRUF. Inflammatory lesions were grouped by size and location. Lesion conspicuity and image quality were rated on an ordinal five-point Likert scale, and lesion detection rates were calculated. Statistical analyses were performed to compare results. Altogether, 568 different lesions were found. Data indicated no significant differences in lesion detection (sensitivity and positive predictive value [PPV]) between FLAIRUF and axially reconstructed 3D-FLAIR (lesion size ≥3 mm × ≥2 mm) and no differences in sensitivity between FLAIRUF and TSE-FLAIR (lesion size ≥3 mm total). Lesion conspicuity in FLAIRUF was similar in all brain regions except for superior conspicuity in the occipital lobe and inferior conspicuity in the central brain regions. Further findings include location-dependent limitations of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as artifacts such as spatial distortions in FLAIRUF. In conclusion, FLAIRUF could potentially be an expedient alternative to conventional methods for brain imaging in MS patients since the acquisition can be performed in a fraction of time while maintaining good image quality.
Collapse
Affiliation(s)
- Martin Schuhholz
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | - Christer Ruff
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | - Eva Bürkle
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | | | | | - Markus Kowarik
- Department of Neurology and Stroke, Neurological Clinic, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | - Benjamin Bender
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| |
Collapse
|
7
|
Mishra S, Srinivasan A, Kelsey L, Bojicic K, Masotti M, Chen Q, Hoeffner E, Kronick S, Gomez-Hassan D. Implementing a rapid cord compression Magnetic Resonance Imaging protocol in the emergency department: Lessons learned. Neuroradiol J 2024:19714009241269540. [PMID: 39115980 DOI: 10.1177/19714009241269540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/10/2024] Open
Abstract
BACKGROUND & PURPOSE (1) Evaluate efficacy of an abbreviated total spine protocol in triaging emergency department (ED) patients through retrospective evaluation. (2) Describe patient outcomes following implementation of a rapid cord compression protocol. METHODS (1) All contrast-enhanced total spine magnetic resonance imaging studies (MRIs) performed on ED patients (n = 75) between 10/1-12/31/2022 for evaluation of cord compression were included. Two readers with 6 and 5 years of experience blindly reviewed the abbreviated protocol (comprised of sagittal T2w and axial T2w sequences) assessing presence of cord compression or severe spinal canal stenosis. Ground truth was consensus by a neuroradiology fellow and 2 attendings. (2) The implemented rapid protocol included sagittal T1w, sagittal T2w Dixon and axial T2w images. All ED patients (n = 85) who were imaged using the rapid protocol from 5/1-8/31/2023 were included. Patient outcomes and call-back rates were determined through chart review. RESULTS (1) Sensitivity and specificity for severe spinal canal stenosis and/or cord compression was 1.0 and 0.92, respectively, for reader 1 and 0.78 and 0.85, respectively, for reader 2. Negative predictive value was 1.0 and 0.97 for readers 1 and 2, respectively. (2) The implemented rapid cord compression protocol resulted in 60% reduction in imaging time at 1.5T. The call-back rate for additional sequences was 7%. In patients who underwent surgery, no additional MRI images were acquired in 82% of cases (9/11). CONCLUSIONS Implementing an abbreviated non-contrast total spine protocol in the ED results in a low call-back rate with acquired MRI images proving sufficient for both triage and treatment planning in most patients.
Collapse
Affiliation(s)
- Shruti Mishra
- Division of Neuroradiology, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Ashok Srinivasan
- Division of Neuroradiology, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Lauren Kelsey
- Division of Neuroradiology, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Katherine Bojicic
- Division of Neuroradiology, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Maria Masotti
- Department of Biostatistics, University of Michigan, Ann Arbor, MI, USA
| | - Qiaochu Chen
- Department of Biostatistics, University of Michigan, Ann Arbor, MI, USA
| | - Ellen Hoeffner
- Division of Neuroradiology, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Steven Kronick
- Department of Emergency Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Diana Gomez-Hassan
- Division of Neuroradiology, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
8
|
Kuo DP, Chen YC, Li YT, Cheng SJ, Hsieh KLC, Kuo PC, Ou CY, Chen CY. Estimating the volume of penumbra in rodents using DTI and stack-based ensemble machine learning framework. Eur Radiol Exp 2024; 8:59. [PMID: 38744784 PMCID: PMC11093947 DOI: 10.1186/s41747-024-00455-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 03/05/2024] [Indexed: 05/16/2024] Open
Abstract
BACKGROUND This study investigates the potential of diffusion tensor imaging (DTI) in identifying penumbral volume (PV) compared to the standard gadolinium-required perfusion-diffusion mismatch (PDM), utilizing a stack-based ensemble machine learning (ML) approach with enhanced explainability. METHODS Sixteen male rats were subjected to middle cerebral artery occlusion. The penumbra was identified using PDM at 30 and 90 min after occlusion. We used 11 DTI-derived metrics and 14 distance-based features to train five voxel-wise ML models. The model predictions were integrated using stack-based ensemble techniques. ML-estimated and PDM-defined PVs were compared to evaluate model performance through volume similarity assessment, the Pearson correlation analysis, and Bland-Altman analysis. Feature importance was determined for explainability. RESULTS In the test rats, the ML-estimated median PV was 106.4 mL (interquartile range 44.6-157.3 mL), whereas the PDM-defined median PV was 102.0 mL (52.1-144.9 mL). These PVs had a volume similarity of 0.88 (0.79-0.96), a Pearson correlation coefficient of 0.93 (p < 0.001), and a Bland-Altman bias of 2.5 mL (2.4% of the mean PDM-defined PV), with 95% limits of agreement ranging from -44.9 to 49.9 mL. Among the features used for PV prediction, the mean diffusivity was the most important feature. CONCLUSIONS Our study confirmed that PV can be estimated using DTI metrics with a stack-based ensemble ML approach, yielding results comparable to the volume defined by the standard PDM. The model explainability enhanced its clinical relevance. Human studies are warranted to validate our findings. RELEVANCE STATEMENT The proposed DTI-based ML model can estimate PV without the need for contrast agent administration, offering a valuable option for patients with kidney dysfunction. It also can serve as an alternative if perfusion map interpretation fails in the clinical setting. KEY POINTS • Penumbral volume can be estimated by DTI combined with stack-based ensemble ML. • Mean diffusivity was the most important feature used for predicting penumbral volume. • The proposed approach can be beneficial for patients with kidney dysfunction.
Collapse
Affiliation(s)
- Duen-Pang Kuo
- Department of Medical Imaging, Taipei Medical University Hospital, No.250, Wu Hsing Street, Taipei, Taiwan
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan
- Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yung-Chieh Chen
- Department of Medical Imaging, Taipei Medical University Hospital, No.250, Wu Hsing Street, Taipei, Taiwan.
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan.
- Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
| | - Yi-Tien Li
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan
- Research Center for Neuroscience, Taipei Medical University, Taipei, Taiwan
- Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, Taipei, Taiwan
| | - Sho-Jen Cheng
- Department of Medical Imaging, Taipei Medical University Hospital, No.250, Wu Hsing Street, Taipei, Taiwan
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan
| | - Kevin Li-Chun Hsieh
- Department of Medical Imaging, Taipei Medical University Hospital, No.250, Wu Hsing Street, Taipei, Taiwan
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan
- Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Po-Chih Kuo
- Department of Computer Science, National Tsing Hua University, Hsinchu, Taiwan
| | - Chen-Yin Ou
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan
| | - Cheng-Yu Chen
- Department of Medical Imaging, Taipei Medical University Hospital, No.250, Wu Hsing Street, Taipei, Taiwan
- Translational Imaging Research Center, Taipei Medical University Hospital, Taipei, Taiwan
- Research Center for Artificial Intelligence in Medicine, Taipei Medical University, Taipei, Taiwan
- Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
- Department of Radiology, National Defense Medical Center, Taipei, Taiwan
| |
Collapse
|
9
|
Lang M, Conklin J. Triage of Patients With Acute Stroke for Endovascular Therapy: Point-Moving Toward MRI-Based Acute Stroke Triage With Ultrafast Protocols. AJR Am J Roentgenol 2024. [PMID: 38691413 DOI: 10.2214/ajr.24.31303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2024]
Affiliation(s)
- Min Lang
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - John Conklin
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
10
|
Kits A, Al-Saadi J, De Luca F, Janzon F, Mazya MV, Lundberg J, Sprenger T, Skare S, Delgado AF. 2.5-Minute Fast Brain MRI with Multiple Contrasts in Acute Ischemic Stroke. Neuroradiology 2024; 66:737-747. [PMID: 38462584 PMCID: PMC11031482 DOI: 10.1007/s00234-024-03331-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 03/04/2024] [Indexed: 03/12/2024]
Abstract
PURPOSE To assess the performance of a 2.5-minute multi-contrast brain MRI sequence (NeuroMix) in diagnosing acute cerebral infarctions. METHODS Adult patients with a clinical suspicion of acute ischemic stroke were retrospectively included. Brain MRI at 3 T included NeuroMix and routine clinical MRI (cMRI) sequences, with DWI/ADC, T2-FLAIR, T2-weighted, T2*, SWI-EPI, and T1-weighted contrasts. Three radiologists (R1-3) independently assessed NeuroMix and cMRI for the presence of acute infarcts (DWI ↑, ADC = or ↓) and infarct-associated abnormalities on other image contrasts. Sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC) were calculated and compared using DeLong's test. Inter- and intra-rater agreements were studied with kappa statistics. Relative DWI (rDWI) and T2-FLAIR (rT2-FLAIR) signal intensity for infarctions were semi-automatically rendered, and the correlation between methods was evaluated. RESULTS According to the reference standard, acute infarction was present in 34 out of 44 (77%) patients (63 ± 17 years, 31 men). Other infarct-associated signal abnormalities were reported in similar frequencies on NeuroMix and cMRI (p > .08). Sensitivity for infarction detection was 94%, 100%, and 94% evaluated by R1, R2, R3, for NeuroMix and 94%, 100%, and 100% for cMRI. Specificity was 100%, 90%, and 100% for NeuroMix and 100%, 100%, and 100% for cMRI. AUC for NeuroMix was .97, .95, and .97 and .97, 1, and 1 for cMRI (DeLong p = 1, .32, .15), respectively. Inter- and intra-rater agreement was κ = .88-1. The correlation between NeuroMix and cMRI was R = .73 for rDWI and R = .83 for rT2-FLAIR. CONCLUSION Fast multi-contrast MRI NeuroMix has high diagnostic performance for detecting acute cerebral infarctions.
Collapse
Affiliation(s)
- Annika Kits
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden.
| | - Jonathan Al-Saadi
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden
| | - Francesca De Luca
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital, Stockholm, Sweden
| | - Fredrik Janzon
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden
- Department of Radiology, Danderyd Hospital, Stockholm, Sweden
| | - Michael V Mazya
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Neurology, Karolinska University Hospital, Stockholm, Sweden
| | - Johan Lundberg
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden
| | - Tim Sprenger
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- MR Applied Science Laboratory Europe, GE Healthcare, Stockholm, Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden
| | - Anna Falk Delgado
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Neuroradiology, Karolinska University Hospital, Solna, 17176, Stockholm, Sweden
| |
Collapse
|
11
|
Rapillo CM, Dunet V, Pistocchi S, Salerno A, Darioli V, Bartolini B, Hajdu SD, Michel P, Strambo D. Moving From CT to MRI Paradigm in Acute Ischemic Stroke: Feasibility, Effects on Stroke Diagnosis and Long-Term Outcomes. Stroke 2024; 55:1329-1338. [PMID: 38488367 PMCID: PMC11045552 DOI: 10.1161/strokeaha.123.045154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Revised: 01/23/2024] [Accepted: 02/05/2024] [Indexed: 04/24/2024]
Abstract
BACKGROUND The relative value of computed tomography (CT) and magnetic resonance imaging (MRI) in acute ischemic stroke (AIS) is debated. In May 2018, our center transitioned from using CT to MRI as first-line imaging for AIS. This retrospective study aims to assess the effects of this paradigm change on diagnosis and disability outcomes. METHODS We compared all consecutive patients with confirmed diagnosis of AIS admitted to our center during the MRI-period (May 2018-August 2022) and an identical number of patients from the preceding CT-period (December 2012-April 2018). Univariable and multivariable analyses were performed to evaluate outcomes, including the number and delay of imaging exams, the rate of missed strokes, stroke mimics treated with thrombolysis, undetermined stroke mechanisms, length of hospitalization, and 3-month disability. RESULTS The median age of the 2972 included patients was 76 years (interquartile range, 65-84), and 46% were female. In the MRI-period, 80% underwent MRI as first acute imaging. The proportion of patients requiring a second acute imaging modality for diagnostic ± revascularization reasons increased from 2.1% to 5% (Punadj <0.05), but it decreased in the subacute phase from 79.0% to 60.1% (Padj <0.05). In thrombolysis candidates, there was a 2-minute increase in door-to-imaging delay (Padj <0.05). The rates of initially missed AIS diagnosis was similar (3.8% versus 4.4%, Padj=0.32) and thrombolysis in stroke mimics decreased by half (8.6% versus 4.3%; Padj <0.05). Rates of unidentified stroke mechanism at hospital discharge were similar (22.8% versus 28.1%; Padj=0.99). The length of hospitalization decreased from 9 (interquartile range, 6-14) to 7 (interquartile range, 4-12) days (Padj=0.62). Disability at 3 months was similar (common adjusted odds ratio for favorable Rankin shift, 0.98 [95% CI, 0.71-1.36]; Padj=0.91), as well as mortality and symptomatic intracranial hemorrhage. CONCLUSIONS A paradigm shift from CT to MRI as first-line imaging for AIS seems feasible in a comprehensive stroke center, with a minimally increased delay to imaging in thrombolysis candidates. MRI was associated with reduced thrombolysis rates of stroke mimics and subacute neuroimaging needs.
Collapse
Affiliation(s)
- Costanza Maria Rapillo
- Stroke Center, Service of Neurology, Department of Clinical Neuroscience (C.M.R., A.S., P.M., D.S.), University Hospital of Lausanne and University of Lausanne, Switzerland
- Stroke Unit, Careggi University Hospital, Florence, Italy (C.M.R.)
| | - Vincent Dunet
- Neuroradiology Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology (V. Dunet, S.P., B.B., S.D.H.), University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Silvia Pistocchi
- Neuroradiology Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology (V. Dunet, S.P., B.B., S.D.H.), University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Alexander Salerno
- Stroke Center, Service of Neurology, Department of Clinical Neuroscience (C.M.R., A.S., P.M., D.S.), University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Vincent Darioli
- Emergency Department (V. Darioli) and Interventional Neuroradiological Unit, University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Bruno Bartolini
- Neuroradiology Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology (V. Dunet, S.P., B.B., S.D.H.), University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Steven David Hajdu
- Neuroradiology Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology (V. Dunet, S.P., B.B., S.D.H.), University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Patrik Michel
- Stroke Center, Service of Neurology, Department of Clinical Neuroscience (C.M.R., A.S., P.M., D.S.), University Hospital of Lausanne and University of Lausanne, Switzerland
| | - Davide Strambo
- Stroke Center, Service of Neurology, Department of Clinical Neuroscience (C.M.R., A.S., P.M., D.S.), University Hospital of Lausanne and University of Lausanne, Switzerland
| |
Collapse
|
12
|
Lang M, Clifford B, Lo WC, Applewhite BP, Tabari A, Filho ALMG, Hosseini Z, Longo MGF, Cauley SF, Setsompop K, Bilgic B, Feiweier T, Lev MH, Schaefer PW, Rapalino O, Huang SY, Conklin J. Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings. AJNR Am J Neuroradiol 2024; 45:379-385. [PMID: 38453413 PMCID: PMC11288578 DOI: 10.3174/ajnr.a8143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 12/07/2023] [Indexed: 03/09/2024]
Abstract
BACKGROUND AND PURPOSE The use of MR imaging in emergency settings has been limited by availability, long scan times, and sensitivity to motion. This study assessed the diagnostic performance of an ultrafast brain MR imaging protocol for evaluation of acute intracranial pathology in the emergency department and inpatient settings. MATERIALS AND METHODS Sixty-six adult patients who underwent brain MR imaging in the emergency department and inpatient settings were included in the study. All patients underwent both the reference and the ultrafast brain MR protocols. Both brain MR imaging protocols consisted of T1-weighted, T2/T2*-weighted, FLAIR, and DWI sequences. The ultrafast MR images were reconstructed by using a machine-learning assisted framework. All images were reviewed by 2 blinded neuroradiologists. RESULTS The average acquisition time was 2.1 minutes for the ultrafast brain MR protocol and 10 minutes for the reference brain MR protocol. There was 98.5% agreement on the main clinical diagnosis between the 2 protocols. In head-to-head comparison, the reference protocol was preferred in terms of image noise and geometric distortion (P < .05 for both). The ultrafast ms-EPI protocol was preferred over the reference protocol in terms of reduced motion artifacts (P < .01). Overall diagnostic quality was not significantly different between the 2 protocols (P > .05). CONCLUSIONS The ultrafast brain MR imaging protocol provides high accuracy for evaluating acute pathology while only requiring a fraction of the scan time. Although there was greater image noise and geometric distortion on the ultrafast brain MR protocol images, there was significant reduction in motion artifacts with similar overall diagnostic quality between the 2 protocols.
Collapse
Affiliation(s)
- Min Lang
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | - Bryan Clifford
- Siemens Medical Solutions (B.C., W.-C.L., Z.H., S.F.C.), Boston, Massachusetts
| | - Wei-Ching Lo
- Siemens Medical Solutions (B.C., W.-C.L., Z.H., S.F.C.), Boston, Massachusetts
| | - Brooks P Applewhite
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | - Azadeh Tabari
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | | | - Zahra Hosseini
- Siemens Medical Solutions (B.C., W.-C.L., Z.H., S.F.C.), Boston, Massachusetts
| | - Maria Gabriela Figueiro Longo
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | - Stephen F Cauley
- Siemens Medical Solutions (B.C., W.-C.L., Z.H., S.F.C.), Boston, Massachusetts
- Harvard-MIT Health Sciences and Technology (S.F.C., B.B., S.Y.H.), Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - Kawin Setsompop
- Departments of Radiology and Electrical Engineering (K.S.), Stanford University, Stanford, California
| | - Berkin Bilgic
- Harvard-MIT Health Sciences and Technology (S.F.C., B.B., S.Y.H.), Massachusetts Institute of Technology, Cambridge, Massachusetts
| | | | - Michael H Lev
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | - Pamela W Schaefer
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | - Otto Rapalino
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| | - Susie Y Huang
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
- Harvard-MIT Health Sciences and Technology (S.F.C., B.B., S.Y.H.), Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - John Conklin
- From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Boston, Massachusetts
| |
Collapse
|
13
|
Oura D, Gekka M, Sugimori H. The montage method improves the classification of suspected acute ischemic stroke using the convolution neural network and brain MRI. Radiol Phys Technol 2024; 17:297-305. [PMID: 37934345 DOI: 10.1007/s12194-023-00754-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 10/15/2023] [Accepted: 10/17/2023] [Indexed: 11/08/2023]
Abstract
This study investigated the usefulness of the montage method that combines four different magnetic resonance images into one images for automatic acute ischemic stroke (AIS) diagnosis with deep learning method. The montage image was consisted from diffusion weighted image (DWI), fluid attenuated inversion recovery (FLAIR), arterial spin labeling (ASL), and apparent diffusion coefficient (ASL). The montage method was compared with pseudo color map (pCM) which was consisted from FLAIR, ASL and ADC. 473 AIS patients were classified into four categories: mechanical thrombectomy, conservative therapy, hemorrhage, and other diseases. The results showed that the montage image significantly outperformed pCM in terms of accuracy (montage image = 0.76 ± 0.01, pCM = 0.54 ± 0.05) and the area under the curve (AUC) (montage image = 0.94 ± 0.01, pCM = 0.76 ± 0.01). This study demonstrates the usefulness of the montage method and its potential for overcoming the limitations of pCM.
Collapse
Affiliation(s)
- Daisuke Oura
- Department of Radiology, Otaru General Hospital, Otaru, 047-0152, Japan
- Graduate School of Health Sciences, Hokkaido University, Sapporo, 060-0812, Japan
| | - Masayuki Gekka
- Department of Neurosurgery, Otaru General Hospital, Otaru, 047-0152, Japan
| | - Hiroyuki Sugimori
- Faculty of Health Sciences, Hokkaido University, Sapporo, 060-0812, Japan.
| |
Collapse
|
14
|
Tu LH, Navaratnam D, Melnick ER, Forman HP, Venkatesh AK, Malhotra A, Yaesoubi R, Sureshanand S, Sheth KN, Mahajan A. CT With CTA Versus MRI in Patients Presenting to the Emergency Department With Dizziness: Analysis Using Propensity Score Matching. AJR Am J Roentgenol 2023; 221:836-845. [PMID: 37404082 DOI: 10.2214/ajr.23.29617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/06/2023]
Abstract
BACKGROUND. CT with CTA is widely used to exclude stroke in patients with dizziness, although MRI has higher sensitivity. OBJECTIVE. The purpose of this article was to compare patients presenting to the emergency department (ED) with dizziness who undergo CT with CTA alone versus those who undergo MRI in terms of stroke-related management and outcomes. METHODS. This retrospective study included 1917 patients (mean age, 59.5 years; 776 men, 1141 women) presenting to the ED with dizziness from January 1, 2018, to December 31, 2021. A first propensity score matching analysis incorporated demographic characteristics, medical history, findings from the review of systems, physical examination findings, and symptoms to construct matched groups of patients discharged from the ED after undergoing head CT with head and neck CTA alone and patients who underwent brain MRI (with or without CT and CTA). Outcomes were compared. A second analysis compared matched patients discharged after CT with CTA alone and patients who underwent specialized abbreviated MRI using multiplanar high-resolution DWI for increased sensitivity for posterior circulation stroke. Sensitivity analyses were performed involving MRI examinations performed as the first or only neuroimaging examination and involving alternative matching and imputation techniques. RESULTS. In the first analysis (406 patients per group), patients who underwent MRI, compared with patients who underwent CT with CTA alone, showed greater frequency of critical neuroimaging results (10.1% vs 4.7%, p = .005), change in secondary stroke prevention medication (9.6% vs 3.2%, p = .001), and subsequent echocardiography evaluation (6.4% vs 1.0%, p < .001). In the second analysis (100 patients per group), patients who underwent specialized abbreviated MRI, compared with patients who underwent CT with CTA alone, showed greater frequency of critical neuroimaging results (10.0% vs 2.0%, p = .04), change in secondary stroke prevention medication (14.0% vs 1.0%, p = .001), and subsequent echocardiography evaluation (12.0% vs 2.0%, p = .01) and lower frequency of 90-day ED readmissions (12.0% vs 28.0%, p = .008). Sensitivity analyses showed qualitatively similar findings. CONCLUSION. A proportion of patients discharged after CT with CTA alone may have benefitted from alternative or additional evaluation by MRI (including MRI using a specialized abbreviated protocol). CLINICAL IMPACT. Use of MRI may motivate clinically impactful management changes in patients presenting with dizziness.
Collapse
Affiliation(s)
- Long H Tu
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, PO Box 208042, Tompkin's East 2, New Haven, CT 06510
| | | | - Edward R Melnick
- Department of Emergency Medicine, Yale School of Medicine, New Haven, CT
| | - Howard P Forman
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, PO Box 208042, Tompkin's East 2, New Haven, CT 06510
| | - Arjun K Venkatesh
- Department of Emergency Medicine, Yale School of Medicine, New Haven, CT
| | - Ajay Malhotra
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, PO Box 208042, Tompkin's East 2, New Haven, CT 06510
| | - Reza Yaesoubi
- Department of Health Policy and Management, Yale School of Public Health, New Haven, CT
| | | | - Kevin N Sheth
- Department of Neurology, Yale School of Medicine, New Haven, CT
| | - Amit Mahajan
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, PO Box 208042, Tompkin's East 2, New Haven, CT 06510
| |
Collapse
|
15
|
Ryu WS, Kang YR, Noh YG, Park JH, Kim D, Kim BC, Park MS, Kim BJ, Kim JT. Acute Infarct Segmentation on Diffusion-Weighted Imaging Using Deep Learning Algorithm and RAPID MRI. J Stroke 2023; 25:425-429. [PMID: 37813675 PMCID: PMC10574298 DOI: 10.5853/jos.2023.02145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 08/07/2023] [Accepted: 08/18/2023] [Indexed: 10/11/2023] Open
Affiliation(s)
- Wi-Sun Ryu
- Artificial Intelligence Research Center, JLK Inc., Seoul, Korea
| | - You-Ri Kang
- Department of Neurology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea
| | - Yoon-Gon Noh
- Artificial Intelligence Research Center, JLK Inc., Seoul, Korea
| | - Jong-Hyeok Park
- Artificial Intelligence Research Center, JLK Inc., Seoul, Korea
| | - Dongmin Kim
- Artificial Intelligence Research Center, JLK Inc., Seoul, Korea
| | - Byeong C. Kim
- Department of Neurology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea
| | - Man-Seok Park
- Department of Neurology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea
| | - Beom Joon Kim
- Department of Neurology and Cerebrovascular Center, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea
| | - Joon-Tae Kim
- Department of Neurology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea
| |
Collapse
|
16
|
Eisenmenger LB, Peret A, Roberts GS, Spahic A, Tang C, Kuner AD, Grayev AM, Field AS, Rowley HA, Kennedy TA. Focused Abbreviated Survey MRI Protocols for Brain and Spine Imaging. Radiographics 2023; 43:e220147. [PMID: 37167089 PMCID: PMC10262597 DOI: 10.1148/rg.220147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 10/12/2022] [Accepted: 10/18/2022] [Indexed: 05/13/2023]
Abstract
There has been extensive growth in both the technical development and the clinical applications of MRI, establishing this modality as one of the most powerful diagnostic imaging tools. However, long examination and image interpretation times still limit the application of MRI, especially in emergent clinical settings. Rapid and abbreviated MRI protocols have been developed as alternatives to standard MRI, with reduced imaging times, and in some cases limited numbers of sequences, to more efficiently answer specific clinical questions. A group of rapid MRI protocols used at the authors' institution, referred to as FAST (focused abbreviated survey techniques), are designed to include or exclude emergent or urgent conditions or screen for specific entities. These FAST protocols provide adequate diagnostic image quality with use of accelerated approaches to produce imaging studies faster than traditional methods. FAST protocols have become critical diagnostic screening tools at the authors' institution, allowing confident and efficient confirmation or exclusion of actionable findings. The techniques commonly used to reduce imaging times, the imaging protocols used at the authors' institution, and future directions in FAST imaging are reviewed to provide a practical and comprehensive overview of FAST MRI for practicing neuroradiologists. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.
Collapse
Affiliation(s)
| | | | - Grant S. Roberts
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Alma Spahic
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Chenwei Tang
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Anthony D. Kuner
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Allison M. Grayev
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Aaron S. Field
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Howard A. Rowley
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| | - Tabassum A. Kennedy
- From the Departments of Radiology (L.B.E., A.P., A.D.K., A.M.G.,
A.S.F., H.A.R., T.A.K.) and Medical Physics (G.S.R., A.S., C.T.), University of
Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI
53792-3252
| |
Collapse
|
17
|
Liu J, Wu Y, Jia W, Han M, Chen Y, Li J, Wu B, Yin S, Zhang X, Chen J, Yu P, Luo H, Tu J, Zhou F, Cheng X, Yi Y. Prediction of recurrence of ischemic stroke within 1 year of discharge based on machine learning MRI radiomics. Front Neurosci 2023; 17:1110579. [PMID: 37214402 PMCID: PMC10192708 DOI: 10.3389/fnins.2023.1110579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 03/06/2023] [Indexed: 05/24/2023] Open
Abstract
Purpose This study aimed to investigate the value of a machine learning-based magnetic resonance imaging (MRI) radiomics model in predicting the risk of recurrence within 1 year following an acute ischemic stroke (AIS). Methods The MRI and clinical data of 612 patients diagnosed with AIS at the Second Affiliated Hospital of Nanchang University from March 1, 2019, to March 5, 2021, were obtained. The patients were divided into recurrence and non-recurrence groups according to whether they had a recurrent stroke within 1 year after discharge. Randomized splitting was used to divide the data into training and validation sets using a ratio of 7:3. Two radiologists used the 3D-slicer software to label the lesions on brain diffusion-weighted (DWI) MRI sequences. Radiomics features were extracted from the annotated images using the pyradiomics software package, and the features were filtered using the Least Absolute Shrinkage and Selection Operator (LASSO) regression analysis. Four machine learning algorithms, logistic regression (LR), Support Vector Classification (SVC), LightGBM, and Random forest (RF), were used to construct a recurrence prediction model. For each algorithm, three models were constructed based on the MRI radiomics features, clinical features, and combined MRI radiomics and clinical features. The sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve (AUC) were used to compare the predictive efficacy of the models. Results Twenty features were selected from 1,037 radiomics features extracted from DWI images. The LightGBM model based on data with three different features achieved the best prediction accuracy from all 4 models in the validation set. The LightGBM model based solely on radiomics features achieved a sensitivity, specificity, and AUC of 0.65, 0.671, and 0.647, respectively, and the model based on clinical data achieved a sensitivity, specificity, and AUC of 0.7, 0.799, 0.735, respectively. The sensitivity, specificity, and AUC of the LightGBM model base on both radiomics and clinical features achieved the best performance with a sensitivity, specificity, and AUC of 0.85, 0.805, 0.789, respectively. Conclusion The ischemic stroke recurrence prediction model based on LightGBM achieved the best prediction of recurrence within 1 year following an AIS. The combination of MRI radiomics features and clinical data improved the prediction performance of the model.
Collapse
Affiliation(s)
- Jianmo Liu
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Yifan Wu
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Weijie Jia
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Mengqi Han
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Yongsen Chen
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Jingyi Li
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Bin Wu
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Shujuan Yin
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Xiaolin Zhang
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Jibiao Chen
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- School of Public Health, Jiangxi Provincial Key Laboratory of Preventive Medicine, Nanchang University, Nanchang, China
| | - Pengfei Yu
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Haowen Luo
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Jianglong Tu
- Department of Neurology, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Fan Zhou
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Xuexin Cheng
- Biological Resource Center, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Yingping Yi
- Department of Medical Big Data Research Centre, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| |
Collapse
|
18
|
de Havenon A, Orlando C, Delic A, McNally JS, Majersik JJ, Harman T, Alexander M, Reddy V, Lyden S, Anzai Y. Direct cost analysis of rapid MRI in the emergency department evaluation of patients suspected of having acute ischemic stroke*. Neuroradiol J 2023; 36:142-147. [PMID: 35701745 PMCID: PMC10034695 DOI: 10.1177/19714009221108681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Abbreviated "rapid MRI" protocols have become more common for the evaluation of acute ischemic stroke (AIS). Prior research has not evaluated the effect of rapid MRIs on cost or hospital length of stay in AIS patients. METHODS We retrospectively identified AIS patients who presented within 6 h of acute neurologic symptom onset to an emergency department (ED) and activated a "brain attack" code. We included sequential patients from January 2012 to September 2015, before rapid MRI was available, who had CT perfusion (CTP) and compared them to patients from October 2015 to May 2018 who had a rapid MRI. We used inverse-probability-weighting (IPW) to balance the cohorts. The primary outcomes were direct cost to our healthcare system and total hospital length of stay (LOS). RESULTS We included 408 brain attack activations (mean ± SD age 62.1 ± 17.6 years, 47.8% male): 257 in the CTP cohort and 151 in the MRI cohort. Discharge diagnosis was ischemic stroke in 193/408 (47.3%). After patient matching, we found significant reductions for the MRI cohort in total cost (-18.7%, 95% CI -35.0, -2.4, p = 0.02) and hospital LOS (-17.0%, 95% CI -31.2, -2.8, p = 0.02), with no difference in ED LOS (p = 0.74) as compared to the CTP cohort. CONCLUSION Although these results are preliminary and hypothesis-generating, we found that the use of a rapid MRI protocol in emergency department brain attacks was associated with a 18.7% reduction in total direct cost and 17% reduction in hospital length of stay.
Collapse
Affiliation(s)
- Adam de Havenon
- Department of Neurology, Yale University, New Haven, CT, USA
| | - Chris Orlando
- Department of Neurology, University of Utah, Salt Lake City, UT, USA
| | - Alen Delic
- Department of Neurology, University of Utah, Salt Lake City, UT, USA
| | | | | | - Tyler Harman
- Department of Neurology, University of Utah, Salt Lake City, UT, USA
| | - Matthew Alexander
- Department of Radiology, University of Utah, Salt Lake City, UT, USA
| | - Vivek Reddy
- Department of Neurology, University of Utah, Salt Lake City, UT, USA
| | - Stephanie Lyden
- Department of Neurology, University of Utah, Salt Lake City, UT, USA
| | - Yoshimi Anzai
- Department of Radiology, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
19
|
Yu Y, Christensen S, Ouyang J, Scalzo F, Liebeskind DS, Lansberg MG, Albers GW, Zaharchuk G. Predicting Hypoperfusion Lesion and Target Mismatch in Stroke from Diffusion-weighted MRI Using Deep Learning. Radiology 2023; 307:e220882. [PMID: 36472536 PMCID: PMC10068889 DOI: 10.1148/radiol.220882] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 09/08/2022] [Accepted: 10/13/2022] [Indexed: 12/12/2022]
Abstract
Background Perfusion imaging is important to identify a target mismatch in stroke but requires contrast agents and postprocessing software. Purpose To use a deep learning model to predict the hypoperfusion lesion in stroke and identify patients with a target mismatch profile from diffusion-weighted imaging (DWI) and clinical information alone, using perfusion MRI as the reference standard. Materials and Methods Imaging data sets of patients with acute ischemic stroke with baseline perfusion MRI and DWI were retrospectively reviewed from multicenter data available from 2008 to 2019 (Imaging Collaterals in Acute Stroke, Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution 2, and University of California, Los Angeles stroke registry). For perfusion MRI, rapid processing of perfusion and diffusion software automatically segmented the hypoperfusion lesion (time to maximum, ≥6 seconds) and ischemic core (apparent diffusion coefficient [ADC], ≤620 × 10-6 mm2/sec). A three-dimensional U-Net deep learning model was trained using baseline DWI, ADC, National Institutes of Health Stroke Scale score, and stroke symptom sidedness as inputs, with the union of hypoperfusion and ischemic core segmentation serving as the ground truth. Model performance was evaluated using the Dice score coefficient (DSC). Target mismatch classification based on the model was compared with that of the clinical-DWI mismatch approach defined by the DAWN trial by using the McNemar test. Results Overall, 413 patients (mean age, 67 years ± 15 [SD]; 207 men) were included for model development and primary analysis using fivefold cross-validation (247, 83, and 83 patients in the training, validation, and test sets, respectively, for each fold). The model predicted the hypoperfusion lesion with a median DSC of 0.61 (IQR, 0.45-0.71). The model identified patients with target mismatch with a sensitivity of 90% (254 of 283; 95% CI: 86, 93) and specificity of 77% (100 of 130; 95% CI: 69, 83) compared with the clinical-DWI mismatch sensitivity of 50% (140 of 281; 95% CI: 44, 56) and specificity of 89% (116 of 130; 95% CI: 83, 94) (P < .001 for all). Conclusion A three-dimensional U-Net deep learning model predicted the hypoperfusion lesion from diffusion-weighted imaging (DWI) and clinical information and identified patients with a target mismatch profile with higher sensitivity than the clinical-DWI mismatch approach. ClinicalTrials.gov registration nos. NCT02225730, NCT01349946, NCT02586415 © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Kallmes and Rabinstein in this issue.
Collapse
Affiliation(s)
- Yannan Yu
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - Soren Christensen
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - Jiahong Ouyang
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - Fabien Scalzo
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - David S. Liebeskind
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - Maarten G. Lansberg
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - Gregory W. Albers
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| | - Greg Zaharchuk
- From the Departments of Radiology (Y.Y., G.Z.), Neurology (S.C.,
M.G.L., G.W.A.), and Electrical Engineering (J.O.), Stanford University, 1201
Welch Rd, PS-04, Mailcode 5488, Stanford, CA 94305-5488; and Department of
Neurology, University of California, Los Angeles, Los Angeles, Calif (F.S.,
D.S.L.)
| |
Collapse
|
20
|
An Update on the Treatment of Basilar Artery Occlusion. Curr Treat Options Neurol 2023. [DOI: 10.1007/s11940-023-00748-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
|
21
|
Patel SD, Liebeskind D. Collaterals and Elusive Ischemic Penumbra. Transl Stroke Res 2023; 14:3-12. [PMID: 36580264 DOI: 10.1007/s12975-022-01116-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 10/09/2022] [Accepted: 12/06/2022] [Indexed: 12/30/2022]
Abstract
As alternative blood supply routes, collateral blood vessels can play a crucial role in determining patient outcomes in acute and chronic intracranial occlusive diseases. Studies have shown that increased collateral circulation can improve functional outcomes and reduce mortality, particularly in those who are not eligible for reperfusion therapy. This article aims to discuss the anatomy and physiology of collateral circulation, describe current imaging tools used to measure collateral circulation, and identify the factors that influence collateral status.
Collapse
Affiliation(s)
- Smit D Patel
- Neurology Department, UCLA Health, Los Angeles, CA, USA.
| | | |
Collapse
|
22
|
A Deep Learning-Based Automatic Collateral Assessment in Patients with Acute Ischemic Stroke. Transl Stroke Res 2023; 14:66-72. [PMID: 35596910 DOI: 10.1007/s12975-022-01036-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 04/17/2022] [Accepted: 05/11/2022] [Indexed: 01/31/2023]
Abstract
This study aimed to develop a supervised deep learning (DL) model for grading collateral status from dynamic susceptibility contrast magnetic resonance perfusion (DSC-MRP) images from patients with large vessel occlusion (LVO) acute ischemic stroke (AIS) and compare its performance against experts' manual grading. Among consecutive LVO-AIS at three medical center sites, DSC-MRP data were processed to generate collateral flow maps consisting of arterial, capillary, and venous phases. With the use of expert readings as a reference, a DL model was developed to analyze collateral status with output classified into good and poor grades. The resulting model was externally validated in a later-collected population from one medical center site. The model was trained on 255 patients and externally validated on 72 patients. In the all-site internal validation population, DL grading of good collateral probability yielded a c statistic of 0.91; in the external validation population, the c statistic was 0.85. In the external validation population, there was moderate agreement between the experts' grades and DL grades (kappa = 0.53, 95% CI = 0.32-0.73, p < 0.0001). Day 7 infarct growth volume was higher in DL-graded poor collateral group than good collateral group patients (median volume [26 mL vs. 6 mL], p = 0.01) in patients with successful reperfusion (modified treatment in cerebral infarction (mTICI) = 2b-3). In all patients with a 90-day modified Rankin Scale (mRS) score, there was a shift to more favorable outcomes in the good collateral group, with a common odds ratio of 2.99 (95% CI = 1.89-4.76, p < 0.0001). The DL-based collateral grading was in good agreement with expert manual grading in both development and validation populations. After exclusion of patients with large infarct volume, early reperfusion is more likely to benefit patients with the poor collateral flow, and the DL method has the potential to aid the assessment of collateral status.
Collapse
|
23
|
Lang M, Rapalino O, Huang S, Lev MH, Conklin J, Wald LL. Emerging Techniques and Future Directions: Fast and Portable Magnetic Resonance Imaging. Magn Reson Imaging Clin N Am 2022; 30:565-582. [PMID: 35995480 DOI: 10.1016/j.mric.2022.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Fast MRI and portable MRI are emerging as promising technologies to improve the speed, efficiency, and availability of MR imaging. Fast MRI methods are increasingly being adopted to create screening protocols for the diagnosis and management of acute pathology in the emergency department. Faster imaging can facilitate timely diagnosis, reduce motion artifacts, and improve departmental MR operations. Point-of-care and portable MRI are emerging technologies that require radiologists to reenvision the role of MRI as a tool with greater accessibility, fewer siting constraints, and the ability to provide valuable diagnostic information at the bedside. Recently introduced commercially available pulse sequences and new MRI scanners are bringing these technologies closer to the patient's clinical setting, and we expect their use to only increase over the coming decade. This article provides an overview of these emerging technologies for emergency radiologists.
Collapse
Affiliation(s)
- Min Lang
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Otto Rapalino
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Susie Huang
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Athinoula A. Martinos Center for Biomedical Imaging, 149 13th Street, Charleston, MA 02129, USA
| | - Michael H Lev
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - John Conklin
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA.
| | - Lawrence L Wald
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Athinoula A. Martinos Center for Biomedical Imaging, 149 13th Street, Charleston, MA 02129, USA
| |
Collapse
|
24
|
Patil S, Rossi R, Jabrah D, Doyle K. Detection, Diagnosis and Treatment of Acute Ischemic Stroke: Current and Future Perspectives. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:748949. [PMID: 35813155 PMCID: PMC9263220 DOI: 10.3389/fmedt.2022.748949] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 06/02/2022] [Indexed: 11/30/2022] Open
Abstract
Stroke is one of the leading causes of disability worldwide. Early diagnosis and treatment of stroke are important for better clinical outcome. Rapid and accurate diagnosis of stroke subtypes is critical. This review discusses the advantages and disadvantages of the current diagnostic and assessment techniques used in clinical practice, particularly for diagnosing acute ischemic stroke. Alternative techniques for rapid detection of stroke utilizing blood based biomarkers and novel portable devices employing imaging methods such as volumetric impedance phase-shift spectroscopy, microwave tomography and Doppler ultrasound are also discussed. Current therapeutic approaches for treating acute ischemic stroke using thrombolytic drugs and endovascular thrombectomy are discussed, with a focus on devices and approaches recently developed to treat large cranial vessel occlusions.
Collapse
Affiliation(s)
- Smita Patil
- CÚRAM, SFI Research Centre for Medical Devices, National University of Ireland Galway, Galway, Ireland
- Department of Physiology, National University of Ireland Galway, Galway, Ireland
| | - Rosanna Rossi
- CÚRAM, SFI Research Centre for Medical Devices, National University of Ireland Galway, Galway, Ireland
- Department of Physiology, National University of Ireland Galway, Galway, Ireland
| | - Duaa Jabrah
- Department of Physiology, National University of Ireland Galway, Galway, Ireland
| | - Karen Doyle
- CÚRAM, SFI Research Centre for Medical Devices, National University of Ireland Galway, Galway, Ireland
- Department of Physiology, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
25
|
Reeder SB, Hess CP, Zaharchuk G, Moy L. Editorial for "Magnetic Resonance Imaging as an Alternative to Contrast-Enhanced Computed Tomography to Mitigate Iodinated Contrast Shortages in the United States: Recommendations From the International Society for Magnetic Resonance in Medicine". J Magn Reson Imaging 2022; 56:655-656. [PMID: 35652484 DOI: 10.1002/jmri.28282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 05/23/2022] [Indexed: 12/11/2022] Open
Affiliation(s)
- Scott B Reeder
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA
| | - Christopher P Hess
- Department of Radiology and Biomedical Imaging, University of California at San Francisco, San Francisco, California, USA
| | - Greg Zaharchuk
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Linda Moy
- Department of Radiology, Langone Medical Center, New York University, New York, New York, USA
| | | |
Collapse
|
26
|
Breutigam NJ, Günther M, Hoinkiss DC, Eickel K, Frost R, Buck MA, Porter DA. Combined acquisition of diffusion and T 2*-weighted measurements using simultaneous multi-contrast magnetic resonance imaging. MAGMA (NEW YORK, N.Y.) 2022; 35:421-440. [PMID: 34855052 PMCID: PMC9188537 DOI: 10.1007/s10334-021-00976-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 11/08/2021] [Accepted: 11/09/2021] [Indexed: 12/14/2022]
Abstract
Object In this work, we present a technique called simultaneous multi-contrast imaging (SMC) to acquire multiple contrasts within a single measurement. Simultaneous multi-slice imaging (SMS) shortens scan time by allowing the repetition time (TR) to be reduced for a given number of slices. SMC imaging preserves TR, while combining different scan types into a single acquisition. This technique offers new opportunities in clinical protocols where examination time is a critical factor and multiple image contrasts must be acquired. Materials and methods High-resolution, navigator-corrected, diffusion-weighted imaging was performed simultaneously with T2*-weighted acquisition at 3 T in a phantom and in five healthy subjects using an adapted readout-segmented EPI sequence (rs-EPI). Results The results demonstrated that simultaneous acquisition of two contrasts (here diffusion-weighted imaging and T2*-weighting) with SMC imaging is feasible with robust separation of contrasts and minimal effect on image quality. Discussion The simultaneous acquisition of multiple contrasts reduces the overall examination time and there is an inherent registration between contrasts. By using the results of this study to control saturation effects in SMC, the method enables rapid acquisition of distortion-matched and well-registered diffusion-weighted and T2*-weighted imaging, which could support rapid diagnosis and treatment of acute stroke. Supplementary Information The online version contains supplementary material available at 10.1007/s10334-021-00976-3.
Collapse
Affiliation(s)
- Nora-Josefin Breutigam
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.
| | - Matthias Günther
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.,Mediri GmbH, Heidelberg, DE, Germany.,University of Bremen, Bremen, DE, Germany
| | - Daniel Christopher Hoinkiss
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany
| | - Klaus Eickel
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.,University of Bremen, Bremen, DE, Germany
| | - Robert Frost
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA.,Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Mareike Alicja Buck
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.,University of Bremen, Bremen, DE, Germany
| | - David A Porter
- Imaging Centre of Excellence (ICE), University of Glasgow, Glasgow, Scotland
| |
Collapse
|
27
|
Af Burén S, Kits A, Lönn L, De Luca F, Sprenger T, Skare S, Falk Delgado A. A 78 Seconds Complete Brain MRI Examination in Ischemic Stroke: A Prospective Cohort Study. J Magn Reson Imaging 2022; 56:884-892. [PMID: 35170134 PMCID: PMC9544312 DOI: 10.1002/jmri.28107] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 02/01/2022] [Accepted: 02/02/2022] [Indexed: 11/08/2022] Open
Abstract
BACKGROUND Fast 78-second multicontrast echo-planar MRI (EPIMix) has shown good diagnostic performance for detecting infarctions at a comprehensive stroke center, but its diagnostic performance has not been evaluated in a prospective study at a primary stroke center. PURPOSE To prospectively determine whether EPIMix was noninferior in detecting ischemic lesions compared to routine clinical MRI. STUDY TYPE Prospective cohort study. POPULATION A total of 118 patients with acute MRI and symptoms of ischemic stroke. FIELD STRENGTH AND SEQUENCE A 3 T. EPIMix (echo-planar based: T1-FLAIR, T2-weighted, T2-FLAIR, T2*, DWI) and routine clinical MRI sequences (T1-weighted fast spin echo, T2-weighted PROPELLER, T2-weighted-FLAIR fast spin echo, T2* gradient echo echo-planar, and DWI spin echo echo-planar). ASSESSMENT Three radiologists, blinded for clinical information, assessed signs of ischemic lesions (DWI↑, ADC↓, and T2/T2-FLAIR↑) on EPIMix and routine clinical MRI, with disagreements solved in consensus with a fourth reader to establish the reference standard. STATISTICAL TESTS Diagnostic performance including sensitivity and specificity against the reference standard was evaluated. EPIMix sensitivity was tested for noninferiority compared to the reference standard using Nam's restricted maximum likelihood estimation (RMLE) Score. A P-value < 0.05 was considered statistically significant. RESULTS Of 118 patients (mean age 62 ± 16 years, 58% males), 25% (n = 30) had MRI signs of acute infarcts. EPIMix was noninferior with 97% (95% CI 83-100) sensitivity for reader 1, 100% (95% CI 88-100) sensitivity for reader 2, and 90% (95% CI 88-98) sensitivity for reader 3 vs. 93% (95% CI 78-99) sensitivity for readers 1 and 2 and 90% (95% CI 74-98) for reader 3 on routine clinical MRI. Specificity was 99% (95% CI 94-100) for reader 1, 100% (95% CI 96-100) for reader 2, and 98% (95% CI 92-100) for reader 3 on EPIMix vs. 100% (95% CI 96-100) for all readers on routine clinical MRI. CONCLUSION EPIMix was noninferior to routine clinical MRI for the diagnosis of acute ischemic stroke. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Siri Af Burén
- Department of Radiology, Capio Saint Göran Hospital, Stockholm, Sweden.,Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| | - Annika Kits
- Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Lucas Lönn
- Department of Radiology, Capio Saint Göran Hospital, Stockholm, Sweden
| | - Francesca De Luca
- Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Tim Sprenger
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.,MR Applied Science Laboratory Europe, GE Healthcare, Stockholm, Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Anna Falk Delgado
- Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
28
|
Benzakoun J, Deslys MA, Legrand L, Hmeydia G, Turc G, Hassen WB, Charron S, Debacker C, Naggara O, Baron JC, Thirion B, Oppenheim C. Synthetic FLAIR as a Substitute for FLAIR Sequence in Acute Ischemic Stroke. Radiology 2022; 303:153-159. [PMID: 35014901 DOI: 10.1148/radiol.211394] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Background In acute ischemic stroke (AIS), fluid-attenuated inversion recovery (FLAIR) is used for treatment decisions when onset time is unknown. Synthetic FLAIR could be generated with deep learning from information embedded in diffusion-weighted imaging (DWI) and could replace acquired FLAIR sequence (real FLAIR) and shorten MRI duration. Purpose To compare performance of synthetic and real FLAIR for DWI-FLAIR mismatch estimation and identification of patients presenting within 4.5 hours from symptom onset. Materials and Methods In this retrospective study, all pretreatment and early follow-up (<48 hours after symptom onset) MRI data sets including DWI (b = 0-1000 sec/mm2) and FLAIR sequences obtained in consecutive patients with AIS referred for reperfusion therapies between January 2002 and May 2019 were included. On the training set (80%), a generative adversarial network was trained to produce synthetic FLAIR with DWI as input. On the test set (20%), synthetic FLAIR was computed without real FLAIR knowledge. The DWI-FLAIR mismatch was evaluated on both FLAIR data sets by four independent readers. Interobserver reproducibility and DWI-FLAIR mismatch concordance between synthetic and real FLAIR were evaluated with κ statistics. Sensitivity and specificity for identification of AIS within 4.5 hours were compared in patients with known onset time by using McNemar test. Results The study included 1416 MRI scans (861 patients; median age, 71 years [interquartile range, 57-81 years]; 375 men), yielding 1134 and 282 scans for training and test sets, respectively. Regarding DWI-FLAIR mismatch, interobserver reproducibility was substantial for real and synthetic FLAIR (κ = 0.80 [95% CI: 0.74, 0.87] and 0.80 [95% CI: 0.74, 0.87], respectively). After consensus, concordance between real and synthetic FLAIR was almost perfect (κ = 0.88; 95% CI: 0.82, 0.93). Diagnostic value for identifying AIS within 4.5 hours did not differ between real and synthetic FLAIR (sensitivity: 107 of 131 [82%] vs 111 of 131 [85%], P = .2; specificity: 96 of 104 [92%] vs 96 of 104 [92%], respectively, P > .99). Conclusion Synthetic fluid-attenuated inversion recovery (FLAIR) had diagnostic performances similar to real FLAIR in depicting diffusion-weighted imaging-FLAIR mismatch and in helping to identify early acute ischemic stroke, and it may accelerate MRI protocols. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Carroll and Hurley in this issue.
Collapse
Affiliation(s)
- Joseph Benzakoun
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Marc-Antoine Deslys
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Laurence Legrand
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Ghazi Hmeydia
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Guillaume Turc
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Wagih Ben Hassen
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Sylvain Charron
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Clément Debacker
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Olivier Naggara
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Jean-Claude Baron
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Bertrand Thirion
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| | - Catherine Oppenheim
- From the Departments of Neuroradiology (J.B., L.L., G.H., W.B.H., O.N., C.O.) and Neurology (G.T., J.C.B.), GHU Paris Psychiatrie et Neurosciences, Site Sainte-Anne, 1 rue Cabanis, 75014 Paris, France; INSERM U1266, Paris, France (J.B., M.A.D., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); Université de Paris, FHU Neurovasc, Paris, France (J.B., L.L., G.T., W.B.H., S.C., C.D., O.N., J.C.B., C.O.); and PARIETAL Team, INRIA, Saclay, France (B.T.)
| |
Collapse
|
29
|
Demir S, Clifford B, Lo WC, Tabari A, Goncalves Filho ALM, Lang M, Cauley SF, Setsompop K, Bilgic B, Lev MH, Schaefer PW, Rapalino O, Huang SY, Hilbert T, Feiweier T, Conklin J. Optimization of magnetization transfer contrast for EPI FLAIR brain imaging. Magn Reson Med 2022; 87:2380-2387. [PMID: 34985151 PMCID: PMC8847235 DOI: 10.1002/mrm.29141] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 12/10/2021] [Accepted: 12/11/2021] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the impact of magnetization transfer (MT) on brain tissue contrast in turbo-spin-echo (TSE) and EPI fluid-attenuated inversion recovery (FLAIR) images, and to optimize an MT-prepared EPI FLAIR pulse sequence to match the tissue contrast of a clinical reference TSE FLAIR protocol. METHODS Five healthy volunteers underwent 3T brain MRI, including single slice TSE FLAIR, multi-slice TSE FLAIR, EPI FLAIR without MT-preparation, and MT-prepared EPI FLAIR with variations of the MT-preparation parameters, including number of preparation pulses, pulse amplitude, and resonance offset. Automated co-registration and gray matter (GM) versus white matter (WM) segmentation was performed using a T1-MPRAGE acquisition, and the GM versus WM signal intensity ratio (contrast ratio) was calculated for each FLAIR acquisition. RESULTS Without MT preparation, EPI FLAIR showed poor tissue contrast (contrast ratio = 0.98), as did single slice TSE FLAIR. Multi-slice TSE FLAIR provided high tissue contrast (contrast ratio = 1.14). MT-prepared EPI FLAIR closely approximated the contrast of the multi-slice TSE FLAIR images for two combinations of the MT-preparation parameters (contrast ratio = 1.14). Optimized MT-prepared EPI FLAIR provided a 50% reduction in scan time compared to the reference TSE FLAIR acquisition. CONCLUSION Optimized MT-prepared EPI FLAIR provides comparable brain tissue contrast to the multi-slice TSE FLAIR images used in clinical practice.
Collapse
Affiliation(s)
- Serdest Demir
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Bryan Clifford
- Siemens Medical Solutions USA, Boston, Massachusetts, USA
| | - Wei-Ching Lo
- Siemens Medical Solutions USA, Boston, Massachusetts, USA
| | - Azadeh Tabari
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | - Min Lang
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Stephen F Cauley
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Athinoula A. Martinos Center for Biomedical Imaging, Boston, Massachusetts, USA
| | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Berkin Bilgic
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Michael H Lev
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Pamela W Schaefer
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Otto Rapalino
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Susie Y Huang
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Athinoula A. Martinos Center for Biomedical Imaging, Boston, Massachusetts, USA
| | | | | | - John Conklin
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Athinoula A. Martinos Center for Biomedical Imaging, Boston, Massachusetts, USA
| |
Collapse
|
30
|
Kakkar P, Kakkar T, Patankar T, Saha S. Current approaches and advances in the imaging of stroke. Dis Model Mech 2021; 14:273651. [PMID: 34874055 PMCID: PMC8669490 DOI: 10.1242/dmm.048785] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
A stroke occurs when the blood flow to the brain is suddenly interrupted, depriving brain cells of oxygen and glucose and leading to further cell death. Neuroimaging techniques, such as computed tomography and magnetic resonance imaging, have greatly improved our ability to visualise brain structures and are routinely used to diagnose the affected vascular region of a stroke patient's brain and to inform decisions about clinical care. Currently, these multimodal imaging techniques are the backbone of the clinical management of stroke patients and have immensely improved our ability to visualise brain structures. Here, we review recent developments in the field of neuroimaging and discuss how different imaging techniques are used in the diagnosis, prognosis and treatment of stroke. Summary: Stroke imaging has undergone seismic shifts in the past decade. Although magnetic resonance imaging (MRI) is superior to computed tomography in providing vital information, further research on MRI is still required to bring its full potential into clinical practice.
Collapse
Affiliation(s)
- Pragati Kakkar
- Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, Leeds LS2 9JT, UK
| | - Tarun Kakkar
- Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, Leeds LS2 9JT, UK
| | | | - Sikha Saha
- Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, Leeds LS2 9JT, UK
| |
Collapse
|
31
|
Peters S, Gärtner F, Austein F, Wodarg F, Jansen O, Hensler J. Evaluation of an Ultra-Short MRI Protocol for Cerebral Staging Examinations in Melanoma Patients. ROFO-FORTSCHR RONTG 2021; 194:409-415. [PMID: 34794187 DOI: 10.1055/a-1669-9408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
PURPOSE Due to its high sensitivity and lack of radiation, MRI is often used to stage cerebral tumors in patients. In contrast, the relatively long examination times and the limited availability of MRI slots at the clinic might delay these examinations. The aim of this study was to compare an ultra-short MRI protocol with the routinely used standard protocol. MATERIALS AND METHODS Cerebral MRI of 147 patients with malignant melanoma were evaluated retrospectively, whereby only two sequences (FLAIR images and contrast-enhanced T1 MPR images) were evaluated in one group and images from the whole examination were available for the second group, including five sequences (DWI, T2 TSE, FLAIR, native and contrast-enhanced T1 TSE, and contrast-enhanced T1 MPR). The results of the two groups were compared and tested to determine whether the ultra-short approach was inferior to the full examination. RESULTS 13.6 % of the patients had cerebral metastases. Overall, 73 metastases were detected: 60 were located supratentorially and 13 infratentorially. Concerning the detection of cerebral metastases, the ultra-short MRI examination, involving only a FLAIR and a contrast-enhanced T1 MPR sequence, was not inferior to the full MRI protocol in general (p = 0.017) and separated by location for supratentorial (p = 0.026) and infratentorial (p = 0.001) metastases. CONCLUSION For staging purposes, a focused, ultra-short MRI protocol is not inferior to a standard MRI examination. This might open up opportunities for faster staging processes and a more efficient use of the often-restricted MRI capacities. KEY POINTS · Short MRI protocols for cerebral staging are not inferior to standard examinations.. · Contrast-enhanced images represent the centerpiece of an ultra-short MRI protocol.. · Short MRI protocols might enable a more efficient use of restricted resources.. CITATION FORMAT · Peters S, Gärtner F, Austein F et al. Evaluation of an Ultra-Short MRI Protocol for Cerebral Staging Examinations in Melanoma Patients. Fortschr Röntgenstr 2021; DOI: 10.1055/a-1669-9408.
Collapse
Affiliation(s)
- Sönke Peters
- Department of Radiology and Neuroradiology, Universitätsklinikum Schleswig-Holstein Campus Kiel, Germany
| | - Friederike Gärtner
- Department of Radiology and Neuroradiology, Universitätsklinikum Schleswig-Holstein Campus Kiel, Germany
| | - Friederike Austein
- Department of Diagnostic and Interventional Neuroradiology, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Fritz Wodarg
- Department of Radiology and Neuroradiology, Universitätsklinikum Schleswig-Holstein Campus Kiel, Germany
| | - Olav Jansen
- Department of Radiology and Neuroradiology, Universitätsklinikum Schleswig-Holstein Campus Kiel, Germany
| | - Johannes Hensler
- Department of Radiology and Neuroradiology, Universitätsklinikum Schleswig-Holstein Campus Kiel, Germany
| |
Collapse
|
32
|
Jaafari O, Gallagher H, Alshehri M, Hakami K, AlShammari M. Diagnostic Value of Perfusion-Weighted Magnetic Resonance Imaging as an Adjunct to Routine Magnetic Resonance Protocols for Adults Presenting with Acute Ischemic Stroke. REPORTS IN MEDICAL IMAGING 2021. [DOI: 10.2147/rmi.s331876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
33
|
Broocks G, Meyer L, Kabiri R, Kniep HC, McDonough R, Bechstein M, van Horn N, Lindner T, Sedlacik J, Cheng B, Thomalla G, Schön G, Fiehler J, Hanning U, Schönfeld MH. Impact of intravenous alteplase on sub-angiographic emboli in high-resolution diffusion-weighted imaging following successful thrombectomy. Eur Radiol 2021; 31:8228-8235. [PMID: 33963911 PMCID: PMC8523452 DOI: 10.1007/s00330-021-07980-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 03/21/2021] [Accepted: 04/01/2021] [Indexed: 12/24/2022]
Abstract
OBJECTIVE Thrombus microfragmentation causing peripheral emboli (PE) during mechanical thrombectomy (MT) may modulate treatment effects, even in cases with successful reperfusion. This study aims to investigate whether intravenous alteplase is of potential benefit in reducing PE after successful MT. METHODS Patients from a prospective study treated at a tertiary care stroke center between 08/2017 and 12/2019 were analyzed. The main inclusion criterion was successful reperfusion after MT (defined as expanded thrombolysis in cerebral infarction (eTICI) scale ≥ 2b50) of large vessel occlusion anterior circulation stroke. All patients received a high-resolution diffusion-weighted imaging (DWI) follow-up 24 h after MT for PE detection. Patients were grouped as "direct MT" (no alteplase) or as MT plus additional intravenous alteplase. The number and volume of ischemic core lesions and PE were then quantified and analyzed. RESULTS Fifty-six patients were prospectively enrolled. Additional intravenous alteplase was administered in 46.3% (26/56). There were no statistically significant differences of PE compared by groups of direct MT and additional intravenous alteplase administration regarding mean numbers (12.1, 95% CI 8.6-15.5 vs. 11.1, 95% CI 7.0-15.1; p = 0.701), and median volume (0.70 mL, IQR 0.21-1.55 vs. 0.39 mL, IQR 0.10-1.62; p = 0.554). In uni- and multivariable linear regression analysis, higher eTICI scores were significantly associated with reduced PE, while the administration of alteplase was neither associated with numbers nor volume of peripheral emboli. Additional alteplase did not alter reperfusion success. CONCLUSIONS Intravenous alteplase neither affects the number nor volume of sub-angiographic DWI-PE after successful endovascular reperfusion. In the light of currently running randomized trials, further studies are warranted to validate these findings. KEY POINTS • Thrombus microfragmentation during endovascular stroke treatment may cause peripheral emboli that are only detectable on diffusion-weighted imaging and may directly compromise treatment effects. • In this prospective study, the application of intravenous alteplase did not influence the occurrence of peripheral emboli detected on high-resolution diffusion-weighted imaging. • A higher degree of recanalization was associated with a reduced number and volume of peripheral emboli and better functional outcome, while contrariwise, peripheral emboli did not modify the effect of recanalization on modified Rankin Scale scores at day 90.
Collapse
Affiliation(s)
- Gabriel Broocks
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| | - Lukas Meyer
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Reza Kabiri
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Helge C Kniep
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Rosalie McDonough
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Matthias Bechstein
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Noel van Horn
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Thomas Lindner
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Jan Sedlacik
- Centre for the Developing Brain & Biomedical Engineering Department, School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK
| | - Bastian Cheng
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Götz Thomalla
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Gerhard Schön
- Institute of Epidemiology and Medical Biometry, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jens Fiehler
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Uta Hanning
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Michael H Schönfeld
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
- Department of Neuroradiology, University Köln, Köln, Germany
| |
Collapse
|
34
|
Scheldeman L, Wouters A, Lemmens R. Imaging selection for reperfusion therapy in acute ischemic stroke beyond the conventional time window. J Neurol 2021; 269:1715-1723. [PMID: 34718883 DOI: 10.1007/s00415-021-10872-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/18/2021] [Accepted: 10/20/2021] [Indexed: 01/15/2023]
Abstract
Originally, the efficacy of acute ischemic stroke treatment with thrombolysis or thrombectomy was only proven in narrow time windows of, respectively, 4.5 and 6 h after onset. Introducing imaging-based selection beyond non-contrast enhanced computed tomography has expanded the treatment window, focusing on presumed tissue status rather than solely on time after stroke onset. Different mismatch concepts have been adopted in clinical practice to select patients in the extended and unknown time window based on findings from randomized controlled trials. Since various concepts exist that can identify patients likely to benefit from reperfusion strategies, clinicians may wonder which imaging modality may be preferred in the emergency setting. In this review, we will discuss the different mismatch concepts and their practical implementation for patient selection for thrombolysis or thrombectomy, beyond the conventional time window.
Collapse
Affiliation(s)
- Lauranne Scheldeman
- Department of Neurology, University Hospitals Leuven, Leuven, Belgium. .,Department of Neurosciences, Experimental Neurology, KU Leuven, University of Leuven, Leuven, Belgium. .,Center for Brain and Disease Research, Laboratory of Neurobiology, VIB, Leuven, Belgium.
| | - Anke Wouters
- Department of Neurology, University Hospitals Leuven, Leuven, Belgium.,Department of Neurosciences, Experimental Neurology, KU Leuven, University of Leuven, Leuven, Belgium.,Center for Brain and Disease Research, Laboratory of Neurobiology, VIB, Leuven, Belgium.,Neurology, Amsterdam University Medical Centers, AMC, Amsterdam, The Netherlands
| | - Robin Lemmens
- Department of Neurology, University Hospitals Leuven, Leuven, Belgium.,Department of Neurosciences, Experimental Neurology, KU Leuven, University of Leuven, Leuven, Belgium.,Center for Brain and Disease Research, Laboratory of Neurobiology, VIB, Leuven, Belgium
| |
Collapse
|
35
|
Cheung J, Doerr M, Hu R, Sun PZ. Refined Ischemic Penumbra Imaging with Tissue pH and Diffusion Kurtosis Magnetic Resonance Imaging. Transl Stroke Res 2021; 12:742-753. [PMID: 33159656 PMCID: PMC8102648 DOI: 10.1007/s12975-020-00868-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 10/14/2020] [Accepted: 10/18/2020] [Indexed: 12/19/2022]
Abstract
Imaging has played a vital role in our mechanistic understanding of acute ischemia and the management of acute stroke patients. The most recent DAWN and DEFUSE-3 trials showed that endovascular therapy could be extended to a selected group of late-presenting stroke patients with the aid of imaging. Although perfusion and diffusion MRI have been commonly used in stroke imaging, the approximation of their mismatch as the penumbra is oversimplified, particularly in the era of endovascular therapy. Briefly, the hypoperfusion lesion includes the benign oligemia that does not proceed to infarction. Also, with prompt and effective reperfusion therapy, a portion of the diffusion lesion is potentially reversible. Therefore, advanced imaging that provides improved ischemic tissue characterization may enable new experimental stroke therapeutics and eventually further individualize stroke treatment upon translation to the clinical setting. Specifically, pH imaging captures tissue of altered metabolic state that demarcates the hypoperfused lesion into ischemic penumbra and benign oligemia, which remains promising to define the ischemic penumbra's outer boundary. On the other hand, diffusion kurtosis imaging (DKI) differentiates the most severely damaged and irreversibly injured diffusion lesion from the portion of diffusion lesion that is potentially reversible, refining the inner boundary of the penumbra. Altogether, the development of advanced imaging has the potential to not only transform the experimental stroke research but also aid clinical translation and patient management.
Collapse
Affiliation(s)
- Jesse Cheung
- Emory College of Arts and Sciences, Emory University, Atlanta, GA, 30329, USA
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, 30329, USA
| | - Madeline Doerr
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, 30329, USA
- Dartmouth College, Hanover, NH, 03755, USA
| | - Ranliang Hu
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton RD NE, Atlanta, GA, 30322, USA
| | - Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, 30329, USA.
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton RD NE, Atlanta, GA, 30322, USA.
| |
Collapse
|
36
|
Joo L, Jung SC, Lee H, Park SY, Kim M, Park JE, Choi KM. Stability of MRI radiomic features according to various imaging parameters in fast scanned T2-FLAIR for acute ischemic stroke patients. Sci Rep 2021; 11:17143. [PMID: 34433881 PMCID: PMC8387477 DOI: 10.1038/s41598-021-96621-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 08/10/2021] [Indexed: 12/18/2022] Open
Abstract
From May 2015 to June 2016, data on 296 patients undergoing 1.5-Tesla MRI for symptoms of acute ischemic stroke were retrospectively collected. Conventional, echo-planar imaging (EPI) and echo train length (ETL)-T2-FLAIR were simultaneously obtained in 118 patients (first group), and conventional, ETL-, and repetition time (TR)-T2-FLAIR were simultaneously obtained in 178 patients (second group). A total of 595 radiomics features were extracted from one region-of-interest (ROI) reflecting the acute and chronic ischemic hyperintensity, and concordance correlation coefficients (CCC) of the radiomics features were calculated between the fast scanned and conventional T2-FLAIR for paired patients (1st group and 2nd group). Stabilities of the radiomics features were compared with the proportions of features with a CCC higher than 0.85, which were considered to be stable in the fast scanned T2-FLAIR. EPI-T2-FLAIR showed higher proportions of stable features than ETL-T2-FLAIR, and TR-T2-FLAIR also showed higher proportions of stable features than ETL-T2-FLAIR, both in acute and chronic ischemic hyperintensities of whole- and intersection masks (p < .002). Radiomics features in fast scanned T2-FLAIR showed variable stabilities according to the sequences compared with conventional T2-FLAIR. Therefore, radiomics features may be used cautiously in applications for feature analysis as their stability and robustness can be variable.
Collapse
Affiliation(s)
- Leehi Joo
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul, 138-736, Republic of Korea
| | - Seung Chai Jung
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul, 138-736, Republic of Korea.
| | - Hyunna Lee
- Bigdata Research Center, Asan Institute for Life Science, Asan Medical Center, 88 Olympic-ro 43-Gil, Songpa-Gu, Seoul, 15505, Republic of Korea.
| | - Seo Young Park
- Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul, 138-736, Korea
| | - Minjae Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul, 138-736, Republic of Korea
| | - Ji Eun Park
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul, 138-736, Republic of Korea
| | - Keum Mi Choi
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul, 138-736, Republic of Korea
| |
Collapse
|
37
|
Liu J, Lin C, Minuti A, Lipton M. Arterial spin labeling compared to dynamic susceptibility contrast MR perfusion imaging for assessment of ischemic penumbra: A systematic review. J Neuroimaging 2021; 31:1067-1076. [PMID: 34388271 DOI: 10.1111/jon.12913] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/23/2021] [Accepted: 07/17/2021] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND AND PURPOSE Dynamic susceptibility contrast (DSC) MR imaging is commonly used to estimate penumbra size in acute ischemic stroke; this technique relies on the administration of gadolinium contrast, which has limited use in certain populations, such as those with impaired renal function or allergies. Arterial spin labeling (ASL) is a relatively new technique that can provide information on cerebral perfusion without need for exogenous contrast agents. This systematic review examines published studies that specifically compared ASL to DSC for assessment of ischemic penumbra. METHODS We searched PubMed, Embase, Web of Science, and the Cochrane Library for papers which compared ASL with DSC for assessment of ischemic penumbra in acute ischemic stroke among adult human populations. Two independent reviewers screened studies using predefined inclusion and exclusion criteria. Study characteristics and findings regarding the utility of ASL compared to DSC for identification of penumbra were then extracted and anlyzed for results and risk of bias. RESULTS Seventeen articles met inclusion and exclusion criteria. Studies compared ASL with DSC on a range of metrics (hypoperfusion, hyperperfusion, mismatch, and reperfusion). Most studies concluded that agreement of ASL with DSC was moderate to very high. A small subset of studies found discrepancy in agreement of ASL with DSC for size or location of perfusion abnormalities. A heterogeneity of perfusion parameters studied for DSC was noted, along with the need for more standardization of research methods. CONCLUSION ASL shows moderate to high agreement with DSC for detection of penumbra among ischemic stroke patients.
Collapse
Affiliation(s)
- Jinyuan Liu
- The Gruss Magnetic Resonance Research Center, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA
| | - Christopher Lin
- The Gruss Magnetic Resonance Research Center, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA
| | - Aurelia Minuti
- The D. Samuel Gottesman Library, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Michael Lipton
- The Gruss Magnetic Resonance Research Center, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA.,Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA.,Department of Psychiatry and Behavioral Sciences, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA.,The Dominick P. Purpura Department of Neuroscience, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA
| |
Collapse
|
38
|
Muddasani V, de Havenon A, McNally JS, Baradaran H, Alexander MD. MR Perfusion in the Evaluation of Mechanical Thrombectomy Candidacy. Top Magn Reson Imaging 2021; 30:197-204. [PMID: 34397969 PMCID: PMC8371677 DOI: 10.1097/rmr.0000000000000277] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
ABSTRACT Stroke is a leading cause of disability and mortality, and the incidence of ischemic stroke is projected to continue to rise in coming decades. These projections emphasize the need for improved imaging techniques for accurate diagnosis allowing effective treatments for ischemic stroke. Ischemic stroke is commonly evaluated with computed tomography (CT) or magnetic resonance imaging (MRI). Noncontrast CT is typically used within 4.5 hours of symptom onset to identify candidates for thrombolysis. Beyond this time window, thrombolytic therapy may lead to poor outcomes if patients are not optimally selected using appropriate imaging. MRI provides an accurate method for the earliest identification of core infarct, and MR perfusion can identify salvageable hypoperfused penumbra. The prognostic value for a better outcome in these patients lies in the ability to distinguish between core infarct and salvageable brain at risk-the ischemic penumbra-which is a function of the degree of ischemia and time. Many centers underutilize MRI for acute evaluation of ischemic stroke. This review will illustrate how perfusion-diffusion mismatch calculated from diffusion-weighted MRI and MR perfusion is a reliable approach for patient selection for stroke therapy and can be performed in timeframes that are comparable to CT-based algorithms while providing potentially superior diagnostic information.
Collapse
Affiliation(s)
| | - Adam de Havenon
- Department of Neurology, University of Utah, Salt Lake City, UT
| | - J Scott McNally
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT
| | - Hediyeh Baradaran
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT
| | - Matthew D Alexander
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT
- Department of Neurosurgery, University of Utah, Salt Lake City, UT
| |
Collapse
|
39
|
Bhattacharjee R, Gupta RK, Das B, Dixit VK, Gupta P, Singh A. Penumbra quantification from MR SWI-DWI mismatch and its comparison with MR ASL PWI-DWI mismatch in patients with acute ischemic stroke. NMR IN BIOMEDICINE 2021; 34:e4526. [PMID: 33880799 DOI: 10.1002/nbm.4526] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 03/26/2021] [Accepted: 03/29/2021] [Indexed: 06/12/2023]
Abstract
In acute-ischemic-stroke patients, penumbra assessment plays a significant role in treatment outcome. MR perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) mismatch ratio can provide penumbra assessment. Recently reported studies have shown the potential of susceptibility-weighted imaging (SWI) in the qualitative assessment of penumbra. We hypothesize that quantitative penumbra assessment using SWI-DWI can provide an alternative to the PWI-DWI approach and this can also reduce the overall scan-time. The purpose of the current study was to develop a framework for accurate quantitative assessment of penumbra using SWI-DWI and its validation with PWI-DWI-based quantification. In the current study, the arterial-spin-labelling (ASL) technique has been used for PWI. This retrospective study included 25 acute-ischemic-stroke patients presenting within 24 hours of the last noted baseline condition of stroke onset. Eleven patients also had follow-up MRI within 48 hours. MRI acquisition comprised DWI, SWI, pseudo-continuous-ASL (pCASL), FLAIR and non-contrast-angiography sequences. A framework was developed for the enhancement of prominent hypo-intense vein signs followed by automatic segmentation of the SWI penumbra ROI. Apparent-diffusion-coefficient (ADC) maps and cerebral-blood-flow (CBF) maps were computed. The infarct core ROI from the ADC map and the ASL penumbra ROI from CBF maps were segmented semiautomatically. The infarct core volume, SWI penumbra volume (SPV) and pCASL penumbra volume were computed and used to calculate mismatch ratios MRSWIADC and MRCBFADC . The Dice coefficient between the SWI penumbra ROI and ASL penumbra ROI was 0.96 ± 0.07. MRSWIADC correlated well (r = 0.90, p < 0.05) with MRCBFADC , which validates the hypothesis of accurate penumbra assessment using the SWI-DWI mismatch ratio. Moreover, a significant association between high SPV and the presence of vessel occlusion in the MR angiogram was observed. Follow-up data showed salvation of penumbra tissue (location and volumes predicted by proposed framework) by treatments. Additionally, functional-outcome analysis revealed 93.3% of patients with MRSWIADC > 1 benefitted from revascularization therapy. Overall, the proposed automated quantitative assessment of penumbra using the SWI-DWI mismatch ratio performs equivalently to the ASL PWI-DWI mismatch ratio. This approach provides an alternative to the perfusion sequence required for penumbra assessment, which can reduce scan time by 17% for the protocol without a perfusion sequence.
Collapse
Affiliation(s)
- Rupsa Bhattacharjee
- Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India
- Philips Health System, Philips India Limited, Gurugram, India
| | - Rakesh Kumar Gupta
- Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurugram, India
| | - Biplab Das
- Department of Interventional Neuroradiology, Fortis Memorial Research Institute, Gurugram, India
- Department of Neurology, Fortis Memorial Research Institute, Gurugram, India
| | - Vijay Kant Dixit
- Department of Interventional Neuroradiology, Fortis Memorial Research Institute, Gurugram, India
| | - Praveen Gupta
- Department of Neurology, Fortis Memorial Research Institute, Gurugram, India
| | - Anup Singh
- Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India
- Department of Biomedical Engineering, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
40
|
Timing the Ischemic Stroke by Multiparametric Quantitative Magnetic Resonance Imaging. Stroke 2021. [DOI: 10.36255/exonpublications.stroke.timingischemicstroke.2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
41
|
Veres G, Vas NF, Lyngby Lassen M, Béresová M, K. Krizsan A, Forgács A, Berényi E, Balkay L. Effect of grey-level discretization on texture feature on different weighted MRI images of diverse disease groups. PLoS One 2021; 16:e0253419. [PMID: 34143830 PMCID: PMC8213143 DOI: 10.1371/journal.pone.0253419] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 06/04/2021] [Indexed: 12/12/2022] Open
Abstract
PURPOSE Many studies of MRI radiomics do not include the discretization method used for the analyses, which might indicate that the discretization methods used are considered irrelevant. Our goals were to compare three frequently used discretization methods (lesion relative resampling (LRR), lesion absolute resampling (LAR) and absolute resampling (AR)) applied to the same data set, along with two different lesion segmentation approaches. METHODS We analyzed the effects of altering bin widths or bin numbers for the three different sampling methods using 40 texture indices (TIs). The impact was evaluated on brain MRI studies obtained for 71 patients divided into three different disease groups: multiple sclerosis (MS, N = 22), ischemic stroke (IS, N = 22), cancer patients (N = 27). Two different MRI acquisition protocols were considered for all patients, a T2- and a post-contrast 3D T1-weighted MRI sequence. Elliptical and manually drawn VOIs were employed for both imaging series. Three different types of gray-level discretization methods were used: LRR, LAR and AR. Hypothesis tests were done among all diseased and control areas to compare the TI values in these areas. We also did correlation analyses between TI values and lesion volumes. RESULTS In general, no significant differences were reported in the results when employing the AR and LAR discretization methods. It was found that employing 38 TIs introduced variation in the results when the number of bin parameters was altered, suggesting that both the degree and direction of monotonicity between each TI value and binning parameters were characteristic for each TI. Furthermore, while TIs were changing with altering binning values, no changes correlated to neither disease nor the MRI sequence. We found that most indices correlated weakly with the volume, while the correlation coefficients were independent of both diseases analyzed and MR contrast. Several cooccurrence-matrix based texture parameters show a definite higher correlation when employing the LRR discretization method However, with the best correlations obtained for the manually drawn VOI. Hypothesis tests among all disease and control areas (co-lateral hemisphere) revealed that the AR or LAR discretization techniques provide more suitable texture features than LRR. In addition, the manually drawn segmentation gave fewer significantly different TIs than the ellipsoid segmentations. In addition, the amount of TIs with significant differences was increasing with increasing the number of bins, or decreasing bin widths. CONCLUSION Our findings indicate that the AR discretization method may offer the best texture analysis in MR image assessments. Employing too many bins or too large bin widths might reduce the selection of TIs that can be used for differential diagnosis. In general, more statistically different TIs were observed for elliptical segmentations when compared to the manually drawn VOIs. In the texture analysis of MR studies, studies and publications should report on all important parameters and methods related to data collection, corrections, normalization, discretization, and segmentation.
Collapse
Affiliation(s)
- Gergő Veres
- Division of Radiology and Imaging Science, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Norman Félix Vas
- Division of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Martin Lyngby Lassen
- Cedars-Sinai Medical Center, AIM Group, Los Angeles, CA, United States of America
- Department of Clinical Physiology, Nuclear Medicine and PET and Cluster for Molecular Imaging, University of Copenhagen, Copenhagen, Denmark
| | - Monika Béresová
- Division of Radiology and Imaging Science, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | | | | | - Ervin Berényi
- Division of Radiology and Imaging Science, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - László Balkay
- Division of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| |
Collapse
|
42
|
Kumar A, Singh VK. Reader Response: Multimodal CT or MRI for IV Thrombolysis in Ischemic Stroke With Unknown Time of Onset. Neurology 2021; 96:1012. [PMID: 34031173 DOI: 10.1212/wnl.0000000000012007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
43
|
Macha K, Hoelter P, Kallmünzer B. Author Response: Multimodal CT or MRI for IV Thrombolysis in Ischemic Stroke With Unknown Time of Onset. Neurology 2021; 96:1013. [PMID: 34031174 DOI: 10.1212/wnl.0000000000012008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
44
|
Zameer S, Siddiqui AS, Riaz R. Multimodality Imaging in Acute Ischemic Stroke. Curr Med Imaging 2021; 17:567-577. [PMID: 33256582 DOI: 10.2174/1573405616666201130094948] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 09/22/2020] [Accepted: 10/14/2020] [Indexed: 11/22/2022]
Abstract
Stroke is the most common cause of mortality and morbidity worldwide. The prognosis of stroke depends upon the area affected and its early treatment. Time is of the essence in the care of stroke patients as it is estimated that approximately 1.9 million neurons, 14 billion synapses, and 12 km myelinated nerve fibers are lost per minute. Therefore, early diagnosis and prompt treatment are necessary. The primary goal of imaging in acute stroke is to diagnose the underlying cause, estimate the area affected, predict response towards thrombolytic therapy and to exclude the conditions mimicking stroke. With advancements in radiology, multiple imaging modalities are available for diagnosis and predicting prognosis. None of them is considered alone to be perfect. In this era of multimodality imaging, the decision of choosing appropriate techniques depends upon purpose and availability. Non-Contrast Computed Tomography is time effective, and helps in excluding other causes, Trans Cranial Doppler is time-effective and cost-effective with wide availability, however, is operator dependent and less sensitive. It holds a great future in sonothrombolysis. Magnetic Resonance Imaging is so far considered to be the most superior one in terms of early diagnosis, planning for interventional treatment and predicting the response of treatment. However, it is limited due to high cost and lack of availability. The current review gives a detailed account of all imaging modalities available for imaging stroke and their associated pros and cons.
Collapse
Affiliation(s)
- Shahla Zameer
- Department of Radiology, Pakistan Institute of Medical Sciences, Islamabad, Pakistan
| | | | - Ramish Riaz
- Department of Radiology, Pakistan Institute of Medical Sciences, Islamabad, Pakistan
| |
Collapse
|
45
|
Heit JJ, Christensen S, Mlynash M, Marks MP, Faizy TD, Lansberg MG, Wintermark M, Bammer R, Albers GW. MR perfusion imaging: Half-dose gadolinium is half the quality. J Neuroimaging 2021; 31:1014-1019. [PMID: 34002424 DOI: 10.1111/jon.12879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/03/2021] [Accepted: 05/05/2021] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND AND PURPOSE Patients with acute ischemic stroke due to a large vessel occlusion (AIS-LVO) undergo emergent neuroimaging triage for thrombectomy treatment. MRI is often utilized for this evaluation, and cerebral magnetic resonance perfusion (MRP) imaging is used to identify the presence of the salvageable penumbra. To determine if dose reduction is feasible, we assessed whether a half-dose reduction in gadobenate provided sufficient MRP quality in AIS-LVO patients. METHODS A prospective observational study of all patients presenting to our neurovascular referral center with AIS-LVO was performed. MRP was done with a half-dose of gadolinium (0.1 ml/kg body weight) over a period of 10 months. MRP images were compared to a consecutive historical cohort of full-dose gadolinium (0.2 ml/kg body weight) MRP studies and rated for image quality (poor, borderline, or good) that determined thrombectomy eligibility. RESULTS Fifty-four half-dose and 127 full-dose patients were included. No differences in patient demographics or stroke presentation details were identified. MRP quality differed between half- and full-dose scans (p < 0.001), which were rated as poor (40.7% vs. 6.3%), borderline (18.5% vs. 26.8%), and good quality (40.7% vs. 66.9%), respectively. MRP image quality was then dichotomized into poor and sufficient (borderline and good) quality groups; half-dose studies were more likely to have poor quality compared to full-dose studies (40.7% vs. 6.3%; p < 0.001). CONCLUSIONS Half-dose gadolinium administration for MRP in AIS-LVO patients results in poor image quality in a substantial number of studies. MR cerebral perfusion performed with half-dose gadolinium may adversely affect stroke patient triage for thrombectomy.
Collapse
Affiliation(s)
- Jeremy J Heit
- Division of Neuroimaging and Neurointervention, Department of Radiology, Stanford University School of Medicine, Stanford, California, USA
| | - Soren Christensen
- Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California, USA
| | - Michael Mlynash
- Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California, USA
| | - Michael P Marks
- Division of Neuroimaging and Neurointervention, Department of Radiology, Stanford University School of Medicine, Stanford, California, USA
| | - Tobias D Faizy
- Division of Neuroimaging and Neurointervention, Department of Radiology, Stanford University School of Medicine, Stanford, California, USA
| | - Maarten G Lansberg
- Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California, USA
| | - Max Wintermark
- Division of Neuroimaging and Neurointervention, Department of Radiology, Stanford University School of Medicine, Stanford, California, USA
| | - Roland Bammer
- Department of Radiology, University of Melbourne, Melbourne, Victoria, Australia
| | - Gregory W Albers
- Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California, USA
| |
Collapse
|
46
|
Kits A, De Luca F, Kolloch J, Müller S, Mazya MV, Skare S, Falk Delgado A. One-Minute Multi-contrast Echo Planar Brain MRI in Ischemic Stroke: A Retrospective Observational Study of Diagnostic Performance. J Magn Reson Imaging 2021; 54:1088-1095. [PMID: 33942426 DOI: 10.1002/jmri.27641] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/27/2021] [Accepted: 03/31/2021] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Fast multi-contrast echo planar MRI (EPIMix) has comparable diagnostic performance to standard MRI for detecting brain pathology but its performance in detecting acute cerebral infarctions has not been determined. PURPOSE To assess the diagnostic performance of EPIMix for the detection of acute cerebral infarctions. STUDY TYPE Retrospective observational cohort. POPULATION One hundred and seventy-two consecutive patients with a clinical suspicion of non-hyperacute ischemic stroke (January 2018 to December 2019). FIELD STRENGTH AND SEQUENCE 1.5 T or 3 T. EPIMix ((echo-planar based: diffusion weighted (DWI), T2*-weighted, T2-weighted, T2- and T1-fluid attenuated inversion recovery (FLAIR) images) vs. standard MRI: echo-planar DWI, echo-planar T2*-weighted or susceptibility weighted, turbo spin-echo T2-weighted, T2- and T1-FLAIR turbo spin-echo sequences. ASSESSMENT Three neuroradiologists rated EPIMix and standard MRI on two separate occasions. Incongruent assessments were resolved in consensus with the fourth reader. The ratings included the diagnostic category (acute infarct, normal, and other pathology). Congruent diagnoses together with consensus diagnoses served as the reference standard. STATISTICAL TESTS The diagnostic performance of EPIMix and standard MRI against the reference standard was calculated by the area under the receiver operating characteristic curve (AUC) and compared by DeLong's test. Sensitivity and specificity were determined. Inter-rater agreements were evaluated by Fleiss's kappa. RESULTS Of 172 patients (61 ± 16 years, 103 men), acute infarcts were present in 80/172 (47%), normal findings in 60/172 (35%), and other pathology in 32/172 (19%). Across readers, the AUCs were .94-.95 for EPIMix and .95-.99 for standard MRI, with overlapping 95% CI (P = .02-.18). Inter-rater agreement for EPIMix was 0.90 and for standard MRI was 0.93. The sensitivity for EPIMix and standard MRI was 88-91% and 91-98%, respectively, while the specificity was 98-100% and 98-99%, both with overlapping 95% CI. CONCLUSION Multi-contrast echo planar MRI showed a high but marginally lower diagnostic performance compared to standard MRI for the detection and characterization of acute brain infarct. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Annika Kits
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Francesca De Luca
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Jens Kolloch
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Susanne Müller
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Michael V Mazya
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neurology, Karolinska University Hospital, Stockholm, Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Anna Falk Delgado
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
47
|
Abstract
Multimodal MR imaging provides valuable information in the management of patients with acute ischemic stroke (AIS), with diagnostic, therapeutic, and prognostic implications. MR imaging plays a critical role in treatment decision making for (1) thrombolytic treatment of AIS patients with unknown symptom-onset and (2) endovascular treatment of patients with large vessel occlusion presenting beyond 6 hours from the symptom onset. MR imaging provides the most accurate information for detection of ischemic brain and is invaluable for differentiating AIS from stroke mimics.
Collapse
|
48
|
He G, Wei L, Lu H, Li Y, Zhao Y, Zhu Y. Advances in imaging acute ischemic stroke: evaluation before thrombectomy. Rev Neurosci 2021; 32:495-512. [PMID: 33600678 DOI: 10.1515/revneuro-2020-0061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 08/05/2020] [Indexed: 11/15/2022]
Abstract
Recent advances in neuroimaging have demonstrated significant assessment benefits and appropriate triage of patients based on specific clinical and radiological features in the acute stroke setting. Endovascular thrombectomy is arguably the most important aspect of acute stroke management with an extended time window. Imaging-based physiological information may potentially shift the treatment paradigm from a rigid time-based model to a more flexible and individualized, tissue-based approach, increasing the proportion of patients amenable to treatment. Various imaging modalities are routinely used in the diagnosis and management of acute ischemic stroke, including multimodal computed tomography (CT) and magnetic resonance imaging (MRI). Therefore, these imaging methods should provide information beyond the presence or absence of intracranial hemorrhage as well as the presence and extent of the ischemic core, collateral circulation and penumbra in patients with neurological symptoms. Target mismatch may optimize selection of patients with late or unknown symptom onset who would potentially be eligible for revascularization therapy. The purpose of this study was to provide a comprehensive review of the current evidence about efficacy and theoretical basis of present imaging modalities, and explores future directions for imaging in the management of acute ischemic stroke.
Collapse
Affiliation(s)
- Guangchen He
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai200233, China
| | - Liming Wei
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai200233, China
| | - Haitao Lu
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai200233, China
| | - Yuehua Li
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai200233, China
| | - Yuwu Zhao
- Department of Neurology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai200233, China
| | - Yueqi Zhu
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai200233, China
| |
Collapse
|
49
|
Christensen S, Amukotuwa S, Lansberg MG, Kemp S, Heit JJ, Mlynash M, Marks MP, Albers GW, Bammer R. Comparison of Tmax values between full- and half-dose gadolinium perfusion studies. J Cereb Blood Flow Metab 2021; 41:336-341. [PMID: 32208802 PMCID: PMC8370009 DOI: 10.1177/0271678x20914537] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
AHA guidelines recommend use of perfusion imaging for patient selection in the 6-24 h window. Recently, the safety of gadolinium-based contrast agents for MR perfusion imaging has been questioned based on findings that gadolinium accumulates in brain tissue. Regulatory bodies have recommended to limit the use of gadolinium-based contrast agents where possible. Focusing specifically on the time to maximum of the tissue residue function (Tmax) parameter, used in DAWN and DEFUSE 3, we hypothesized that half-dose scans would yield a similar Tmax delay pattern to full-dose scans. We prospectively recruited 10 acute ischemic stroke patients imaged with two perfusion scans at their follow-up visit, one with a standard dose gadolinium followed by a half-dose injection a median of 7 min apart. The brain was parcellated into a grid of 3 × 3 regions and the mean of the difference in Tmax between the 3 × 3 regions on the half- and full-dose Tmax maps was 0.1 s (iqr 0.38 s). The fraction of brain tissue that differed by no more than ±1 s was 93.7%. In patients with normal or modest Tmax delays, half-dose gadolinium appears to provide comparable Tmax measurements to those of full-dose scans.
Collapse
Affiliation(s)
- Søren Christensen
- Stanford Stroke Center, Stanford University School of Medicine,
Stanford, CA, USA
| | - Shalini Amukotuwa
- Diagnostic Imaging, Monash Health, Clayton, Australia
- Department of Radiology, Barwon Health, Geelong, Australia
| | - Maarten G Lansberg
- Stanford Stroke Center, Stanford University School of Medicine,
Stanford, CA, USA
| | - Stephanie Kemp
- Stanford Stroke Center, Stanford University School of Medicine,
Stanford, CA, USA
| | - Jeremy J Heit
- Diagnostic and Interventional Neuroradiology Department,
Stanford University School of Medicine, Stanford, CA, USA
| | - Michael Mlynash
- Stanford Stroke Center, Stanford University School of Medicine,
Stanford, CA, USA
| | - Michael P Marks
- Diagnostic and Interventional Neuroradiology Department,
Stanford University School of Medicine, Stanford, CA, USA
| | - Greg W Albers
- Department of Radiology, Barwon Health, Geelong, Australia
- Greg W Albers, Stanford Stroke Center, 780
Welch Rd, Palo Alto, CA 94304, USA.
| | - Roland Bammer
- Department of Radiology, University of Melbourne, Parkville,
Australia
| |
Collapse
|
50
|
Oztek MA, Brunnquell CL, Hoff MN, Boulter DJ, Mossa-Basha M, Beauchamp LH, Haynor DL, Nguyen XV. Practical Considerations for Radiologists in Implementing a Patient-friendly MRI Experience. Top Magn Reson Imaging 2021; 29:181-186. [PMID: 32511199 DOI: 10.1097/rmr.0000000000000247] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
For many patients, numerous unpleasant features of the magnetic resonance imaging (MRI) experience such as scan duration, auditory noise, spatial confinement, and motion restrictions can lead to premature termination or low diagnostic quality of imaging studies. This article discusses practical, patient-oriented considerations that are helpful for radiologists contemplating ways to improve the MRI experience for patients. Patient friendly scanner properties are discussed, with an emphasis on literature findings of effectiveness in mitigating patient claustrophobia, other anxiety, or motion and on reducing scan incompletion rates or need for sedation. As shorter scanning protocols designed to answer specific diagnostic questions may be more practical and tolerable to the patient than a full-length standard-of-care examination, a few select protocol adjustments potentially useful for specific clinical settings are discussed. In addition, adjunctive devices such as audiovisual or other sensory aides that can be useful distractive approaches to reduce patient discomfort are considered. These modifications to the MRI scanning process not only allow for a more pleasant experience for patients, but they may also increase patient compliance and decrease patient movement to allow more efficient acquisition of diagnostic-quality images.
Collapse
Affiliation(s)
- Murat Alp Oztek
- Department of Radiology, University of Washington School of Medicine, Seattle, WA.,Department of Radiology, Seattle Children's Hospital, Seattle, WA
| | | | - Michael N Hoff
- Department of Radiology, University of Washington School of Medicine, Seattle, WA
| | - Daniel J Boulter
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Mahmud Mossa-Basha
- Department of Radiology, University of Washington School of Medicine, Seattle, WA
| | - Luke H Beauchamp
- Michigan State University College of Human Medicine, East Lansing, MI
| | - David L Haynor
- Department of Radiology, University of Washington School of Medicine, Seattle, WA
| | - Xuan V Nguyen
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH
| |
Collapse
|