1
|
Wittenstein J, Huhle R, Mutschke AK, Piorko S, Kramer T, Dorfinger L, Tempel F, Jäger M, Schweigert M, Mauer R, Koch T, Richter T, Scharffenberg M, Gama de Abreu M. Comparative effects of variable versus conventional volume-controlled one-lung ventilation on gas exchange and respiratory system mechanics in thoracic surgery patients: A randomized controlled clinical trial. J Clin Anesth 2024; 95:111444. [PMID: 38583224 DOI: 10.1016/j.jclinane.2024.111444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 03/06/2024] [Accepted: 03/09/2024] [Indexed: 04/09/2024]
Abstract
BACKGROUND Mechanical ventilation with variable tidal volumes (V-VCV) has the potential to improve lung function during general anesthesia. We tested the hypothesis that V-VCV compared to conventional volume-controlled ventilation (C-VCV) would improve intraoperative arterial oxygenation and respiratory system mechanics in patients undergoing thoracic surgery under one-lung ventilation (OLV). METHODS Patients were randomized to V-VCV (n = 39) or C-VCV (n = 39). During OLV tidal volume of 5 mL/kg predicted body weight (PBW) was used. Both groups were ventilated with a positive end-expiratory pressure (PEEP) of 5 cm H2O, inspiration to expiration ratio (I:E) of 1:1 (during OLV) and 1:2 during two-lung ventilation, the respiratory rate (RR) titrated to arterial pH, inspiratory peak-pressure ≤ 40 cm H2O and an inspiratory oxygen fraction of 1.0. RESULTS Seventy-five out of 78 Patients completed the trial and were analyzed (dropouts were excluded). The partial pressure of arterial oxygen (PaO2) 20 min after the start of OLV did not differ among groups (V-VCV: 25.8 ± 14.6 kPa vs C-VCV: 27.2 ± 15.3 kPa; mean difference [95% CI]: 1.3 [-8.2, 5.5], P = 0.700). Furthermore, intraoperative gas exchange, intraoperative adverse events, need for rescue maneuvers due to desaturation and hypercapnia, incidence of postoperative pulmonary and extra-pulmonary complications, and hospital free days at day 30 after surgery did not differ between groups. CONCLUSIONS In thoracic surgery patients under OLV, V-VCV did not improve oxygenation or respiratory system mechanics compared to C-VCV. Ethical Committee: EK 420092019. TRIAL REGISTRATION at the German Clinical Trials Register: DRKS00022202 (16.06.2020).
Collapse
Affiliation(s)
- Jakob Wittenstein
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Robert Huhle
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Anne-Kathrin Mutschke
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Sarah Piorko
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Tim Kramer
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Laurin Dorfinger
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Franz Tempel
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Maxim Jäger
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Michael Schweigert
- Department of Thoracic Surgery, University Hospital Schleswig-Holstein, Luebeck, Germany
| | - René Mauer
- Faculty of Medicine Carl Gustav Carus, Institute for Medical Informatics and Biometry (IMB), Technische Universität, Dresden, Germany
| | - Thea Koch
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Torsten Richter
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Martin Scharffenberg
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany
| | - Marcelo Gama de Abreu
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus Dresden, TUD Dresden University of Technology, Dresden, Germany; Department of Intensive Care and Resuscitation, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH, United States; Department of Cardiothoracic Anesthesia, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH, United States; Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH, United States.
| |
Collapse
|
2
|
Dos Santos Rocha A, Petak F, Carvalho T, Habre W, Balogh AL. Physiologically variable ventilation prevents lung function deterioration in a model of pulmonary fibrosis. J Appl Physiol (1985) 2022; 132:915-924. [PMID: 35201935 DOI: 10.1152/japplphysiol.00670.2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Positive pressure ventilation exerts an increased stress and strain in the presence of pulmonary fibrosis. Thus, ventilation strategies that avoid high pressures while maintaining lung aeration are of paramount importance. While physiologically variable ventilation (PVV) has proven beneficial in various models of pulmonary disease, its potential advantages in pulmonary fibrosis have not been investigated. Therefore, we assessed the benefit of PVV over conventional pressure-controlled ventilation (PCV) in a model of pulmonary fibrosis. Lung fibrosis was induced with intratracheal bleomycin in rabbits. Fifty days later, the animals were randomized to receive 6 hours of either PCV (n=10) or PVV (n=11). The PVV pattern was prerecorded in spontaneously breathing, healthy rabbits. Respiratory mechanics and gas exchange were assessed hourly, end-expiratory lung volume and intrapulmonary shunt fraction were measured at hours 0 and 6. Histological and cellular analyses were performed. Fifty days after bleomycin treatment, the rabbits presented elevated specific airway resistance (69±26% [mean±95%confidence interval]), specific tissue damping (38±15%) and specific elastance (47±16%) along with histological evidence of fibrosis. Six hours of PCV led to increased respiratory airway resistance (Raw, 111±30%), tissue damping (G, 36±13%) and elastance (H, 58±14%), and decreased end-expiratory lung volume (EELV, -26±7%) and oxygenation (PaO2/FiO2, -14±5%). The time-matched changes in the PVV group were significantly lower for G (22±9%), H (41±6%), EELV (-13±6%) and PaO2/FiO2 ratio (-3±5%, p<0.05 for all). There was no difference in histopathology between the ventilation modes. Thus, prolonged application of PVV prevented the deterioration of gas exchange by reducing atelectasis development in bleomycin-induced lung fibrosis.
Collapse
Affiliation(s)
- Andre Dos Santos Rocha
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva and University of Geneva, Geneva, Switzerland
| | - Ferenc Petak
- Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary
| | - Tânia Carvalho
- Histology and Comparative Pathology Laboratory, Instituto de Medicina Molecular, Lisbon, Portugal
| | - Walid Habre
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva and University of Geneva, Geneva, Switzerland.,Pediatric Anesthesia Unit, Geneva Children's Hospital, Geneva, Switzerland
| | - Adam L Balogh
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva and University of Geneva, Geneva, Switzerland
| |
Collapse
|
3
|
Dos Santos Rocha A, Südy R, Bizzotto D, Kassai M, Carvalho T, Dellacà RL, Peták F, Habre W. Benefit of Physiologically Variable Over Pressure-Controlled Ventilation in a Model of Chronic Obstructive Pulmonary Disease: A Randomized Study. Front Physiol 2021; 11:625777. [PMID: 33519528 PMCID: PMC7839245 DOI: 10.3389/fphys.2020.625777] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 12/15/2020] [Indexed: 11/25/2022] Open
Abstract
Introduction The advantages of physiologically variable ventilation (PVV) based on a spontaneous breathing pattern have been demonstrated in several respiratory conditions. However, its potential benefits in chronic obstructive pulmonary disease (COPD) have not yet been characterized. We used an experimental model of COPD to compare respiratory function outcomes after 6 h of PVV versus conventional pressure-controlled ventilation (PCV). Materials and Methods Rabbits received nebulized elastase and lipopolysaccharide throughout 4 weeks. After 30 days, animals were anesthetized, tracheotomized, and randomized to receive 6 h of physiologically variable (n = 8) or conventional PCV (n = 7). Blood gases, respiratory mechanics, and chest fluoroscopy were assessed hourly. Results After 6 h of ventilation, animals receiving variable ventilation demonstrated significantly higher oxygenation index (PaO2/FiO2 441 ± 37 (mean ± standard deviation) versus 354 ± 61 mmHg, p < 0.001) and lower respiratory elastance (359 ± 36 versus 463 ± 81 cmH2O/L, p < 0.01) than animals receiving PCV. Animals ventilated with the variable mode also presented less lung derecruitment (decrease in lung aerated area, –3.4 ± 9.9 versus –17.9 ± 6.7%, p < 0.01) and intrapulmonary shunt fraction (9.6 ± 4.1 versus 17.0 ± 5.8%, p < 0.01). Conclusion PVV applied to a model of COPD improved oxygenation, respiratory mechanics, lung aeration, and intrapulmonary shunt fraction compared to conventional ventilation. A reduction in alveolar derecruitment and lung tissue stress leading to better aeration and gas exchange may explain the benefits of PVV.
Collapse
Affiliation(s)
- Andre Dos Santos Rocha
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| | - Roberta Südy
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| | - Davide Bizzotto
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Miklos Kassai
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| | - Tania Carvalho
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Lisbon, Portugal
| | - Raffaele L Dellacà
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Ferenc Peták
- Department of Medical Physics and Informatics, Faculty of Medicine, University of Szeged, Szeged, Hungary
| | - Walid Habre
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| |
Collapse
|
4
|
Bou Jawde S, Walkey AJ, Majumdar A, O'Connor GT, Smith BJ, Bates JHT, Lutchen KR, Suki B. Tracking respiratory mechanics around natural breathing rates via variable ventilation. Sci Rep 2020; 10:6722. [PMID: 32317734 PMCID: PMC7174375 DOI: 10.1038/s41598-020-63663-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 03/26/2020] [Indexed: 11/08/2022] Open
Abstract
Measuring respiratory resistance and elastance as a function of time, tidal volume, respiratory rate, and positive end-expiratory pressure can guide mechanical ventilation. However, current measurement techniques are limited since they are assessed intermittently at non-physiological frequencies or involve specialized equipment. To this end, we introduce ZVV, a practical approach to continuously track resistance and elastance during Variable Ventilation (VV), in which frequency and tidal volume vary from breath-to-breath. ZVV segments airway pressure and flow recordings into individual breaths, calculates resistance and elastance for each breath, bins them according to frequency or tidal volume and plots the results against bin means. ZVV's feasibility was assessed clinically in five human patients with acute lung injury, experimentally in five mice ventilated before and after lavage injury, and computationally using a viscoelastic respiratory model. ZVV provided continuous measurements in both settings, while the computational study revealed <2% estimation errors. Our findings support ZVV as a feasible technique to assess respiratory mechanics under physiological conditions. Additionally, in humans, ZVV detected a decrease in resistance and elastance with time by 12.8% and 6.2%, respectively, suggesting that VV can improve lung recruitment in some patients and can therefore potentially serve both as a dual diagnostic and therapeutic tool.
Collapse
Affiliation(s)
- Samer Bou Jawde
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - Allan J Walkey
- Department of Medicine, Pulmonary, Allergy, Sleep, & Critical Care Medicine, Boston University, Boston, MA, USA
| | - Arnab Majumdar
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - George T O'Connor
- Department of Medicine, Pulmonary, Allergy, Sleep, & Critical Care Medicine, Boston University, Boston, MA, USA
| | - Bradford J Smith
- Department of Bioengineering, University of Colorado Denver | Anschutz Medical Campus, Aurora, CO, USA
| | - Jason H T Bates
- Pulmonary/Critical Care Division, University of Vermont, Burlington, VT, USA
| | - Kenneth R Lutchen
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - Béla Suki
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
| |
Collapse
|
5
|
Wittenstein J, Scharffenberg M, Braune A, Huhle R, Bluth T, Herzog M, Güldner A, Ball L, Simonassi F, Zeidler-Rentzsch I, Vidal Melo MF, Koch T, Rocco PRM, Pelosi P, Kotzerke J, Gama de Abreu M, Kiss T. Effects of variable versus nonvariable controlled mechanical ventilation on pulmonary inflammation in experimental acute respiratory distress syndrome in pigs. Br J Anaesth 2020; 124:430-439. [PMID: 32033744 PMCID: PMC8016484 DOI: 10.1016/j.bja.2019.12.040] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 12/18/2019] [Accepted: 12/23/2019] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Mechanical ventilation with variable tidal volumes (VT) may improve lung function and reduce ventilator-induced lung injury in experimental acute respiratory distress syndrome (ARDS). However, previous investigations were limited to less than 6 h, and control groups did not follow clinical standards. We hypothesised that 24 h of mechanical ventilation with variable VT reduces pulmonary inflammation (as reflected by neutrophil infiltration), compared with standard protective, nonvariable ventilation. METHODS Experimental ARDS was induced in 14 anaesthetised pigs with saline lung lavage followed by injurious mechanical ventilation. Pigs (n=7 per group) were randomly assigned to using variable VT or nonvariable VT modes of mechanical ventilation for 24 h. In both groups, ventilator settings including positive end-expiratory pressure and oxygen inspiratory fraction were adjusted according to the ARDS Network protocol. Pulmonary inflammation (primary endpoint) and perfusion were assessed by positron emission tomography using 2-deoxy-2-[18F]fluoro-d-glucose and 68Gallium (68Ga)-labelled microspheres, respectively. Gas exchange, respiratory mechanics, and haemodynamics were quantified. Lung aeration was determined using CT. RESULTS The specific global uptake rate of 18F-FDG increased to a similar extent regardless of mode of mechanical ventilation (median uptake for variable VT=0.016 min-1 [inter-quartile range, 0.012-0.029] compared with median uptake for nonvariable VT=0.037 min-1 [0.008-0.053]; P=0.406). Gas exchange, respiratory mechanics, haemodynamics, and lung aeration and perfusion were similar in both variable and nonvariable VT ventilatory modes. CONCLUSION In a porcine model of ARDS, 24 h of mechanical ventilation with variable VT did not attenuate pulmonary inflammation compared with standard protective mechanical ventilation with nonvariable VT.
Collapse
Affiliation(s)
- Jakob Wittenstein
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Martin Scharffenberg
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Anja Braune
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Robert Huhle
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Thomas Bluth
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Moritz Herzog
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Andreas Güldner
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Lorenzo Ball
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Genoa, Italy; Anesthesia and Intensive Care, San Martino Policlinico Hospital, IRCCS for Oncology and Neurosciences, Genoa, Italy
| | - Francesca Simonassi
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Genoa, Italy; Anesthesia and Intensive Care, San Martino Policlinico Hospital, IRCCS for Oncology and Neurosciences, Genoa, Italy
| | - Ines Zeidler-Rentzsch
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; Department of Orthodontics, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Marcos F Vidal Melo
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard University, Boston, MA, USA
| | - Thea Koch
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Patricia R M Rocco
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Paolo Pelosi
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Genoa, Italy; Anesthesia and Intensive Care, San Martino Policlinico Hospital, IRCCS for Oncology and Neurosciences, Genoa, Italy
| | - Jörg Kotzerke
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Marcelo Gama de Abreu
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Thomas Kiss
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
| |
Collapse
|
6
|
Fodor GH, Bayat S, Albu G, Lin N, Baudat A, Danis J, Peták F, Habre W. Variable Ventilation Is Equally Effective as Conventional Pressure Control Ventilation for Optimizing Lung Function in a Rabbit Model of ARDS. Front Physiol 2019; 10:803. [PMID: 31297064 PMCID: PMC6607923 DOI: 10.3389/fphys.2019.00803] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 06/06/2019] [Indexed: 11/24/2022] Open
Abstract
Background Introducing mathematically derived variability (MVV) into the otherwise monotonous conventional mechanical ventilation has been suggested to improve lung recruitment and gas exchange. Although the application of a ventilation pattern based on variations in physiological breathing (PVV) is beneficial for healthy lungs, its value in the presence of acute respiratory distress syndrome (ARDS) has not been characterized. We therefore aimed at comparing conventional pressure-controlled ventilation with (PCS) or without regular sighs (PCV) to MVV and PVV at two levels of positive end-expiratory pressure (PEEP) in a model of severe ARDS. Methods Anesthetised rabbits (n = 54) were mechanically ventilated and severe ARDS (PaO2/FiO2 ≤ 150 mmHg) was induced by combining whole lung lavage, i.v. endotoxin and injurious ventilation. Rabbits were then randomly assigned to be ventilated with PVV, MVV, PCV, or PCS for 5 h while maintaining either 6 or 9 cmH2O PEEP. Ventilation parameters, blood gas indices and respiratory mechanics (tissue damping, G, and elastance, H) were recorded hourly. Serum cytokine levels were assessed with ELISA and lung histology was analyzed. Results Although no progression of lung injury was observed after 5 h of ventilation at PEEP 6 cmH2O with PVV and PCV, values for G (58.8 ± 71.1[half-width of 95% CI]% and 40.8 ± 39.0%, respectively), H (54.5 ± 57.2%, 50.7 ± 28.3%), partial pressure of carbon-dioxide (PaCO2, 43.9 ± 23.8%, 46.2 ± 35.4%) and pH (−4.6 ± 3.3%, −4.6 ± 2.2%) worsened with PCS and MVV. Regardless of ventilation pattern, application of a higher PEEP improved lung function and precluded progression of lung injury and inflammation. Histology lung injury scores were elevated in all groups with no difference between groups at either PEEP level. Conclusion At moderate PEEP, variable ventilation based on a pre-recorded physiological breathing pattern protected against progression of lung injury equally to the conventional pressure-controlled mode, whereas mathematical variability or application of regular sighs caused worsening in lung mechanics. This outcome may be related to the excessive increases in peak inspiratory pressure with the latter ventilation modes. However, a greater benefit on respiratory mechanics and gas exchange could be obtained by elevating PEEP, compared to the ventilation mode in severe ARDS.
Collapse
Affiliation(s)
- Gergely H Fodor
- Unit for Anesthesiological Investigations, Geneva University Hospitals - University of Geneva, Geneva, Switzerland
| | - Sam Bayat
- Unit for Anesthesiological Investigations, Geneva University Hospitals - University of Geneva, Geneva, Switzerland.,Inserm UA7 STROBE Laboratory, Department of Clinical Physiology, Sleep and Exercise, Grenoble University Hospital, Grenoble, France
| | - Gergely Albu
- Unit for Anesthesiological Investigations, Geneva University Hospitals - University of Geneva, Geneva, Switzerland
| | - Na Lin
- Unit for Anesthesiological Investigations, Geneva University Hospitals - University of Geneva, Geneva, Switzerland.,Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Aurélie Baudat
- Unit for Anesthesiological Investigations, Geneva University Hospitals - University of Geneva, Geneva, Switzerland
| | - Judit Danis
- MTA-SZTE Dermatological Research Group, University of Szeged, Szeged, Hungary
| | - Ferenc Peták
- Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary
| | - Walid Habre
- Unit for Anesthesiological Investigations, Geneva University Hospitals - University of Geneva, Geneva, Switzerland
| |
Collapse
|
7
|
Mellenthin MM, Seong SA, Roy GS, Bartolák-Suki E, Hamlington KL, Bates JHT, Smith BJ. Using injury cost functions from a predictive single-compartment model to assess the severity of mechanical ventilator-induced lung injuries. J Appl Physiol (1985) 2019; 127:58-70. [PMID: 31046518 DOI: 10.1152/japplphysiol.00770.2018] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Identifying safe ventilation patterns for patients with acute respiratory distress syndrome remains challenging because of the delicate balance between gas exchange and selection of ventilator settings to prevent further ventilator-induced lung injury (VILI). Accordingly, this work seeks to link ventilator settings to graded levels of VILI to identify injury cost functions that predict injury by using a computational model to process pressures and flows measured at the airway opening. Pressure-volume loops were acquired over the course of ~2 h of mechanical ventilation in four different groups of BALB/c mice. A cohort of these animals were subjected to an injurious bronchoalveolar lavage before ventilation. The data were analyzed with a single-compartment model that predicts recruitment/derecruitment and tissue distension at each time step in measured pressure-volume loops. We compared several injury cost functions to markers of VILI-induced blood-gas barrier disruption. Of the cost functions considered, we conclude that mechanical power dissipation and strain heterogeneity are the best at distinguishing between graded levels of injury and are good candidates for forecasting the development of VILI. NEW & NOTEWORTHY This work uses a predictive single-compartment model and injury cost functions to assess graded levels of mechanical ventilator-induced lung injury. The most promising measures include strain heterogeneity and mechanical power dissipation.
Collapse
Affiliation(s)
| | - Siyeon A Seong
- College of Medicine, University of Vermont , Burlington, Vermont
| | - Gregory S Roy
- College of Medicine, University of Vermont , Burlington, Vermont
| | | | - Katharine L Hamlington
- College of Medicine, University of Vermont , Burlington, Vermont.,University of Colorado at Children's Hospital Colorado , Aurora, Colorado
| | - Jason H T Bates
- College of Medicine, University of Vermont , Burlington, Vermont
| | - Bradford J Smith
- Department of Bioengineering, University of Colorado Denver , Aurora, Colorado.,College of Medicine, University of Vermont , Burlington, Vermont
| |
Collapse
|
8
|
Nataj A, Eftekhari G, Raoufy MR, Mani AR. The effect of fractal-like mechanical ventilation on vital signs in a rat model of acute-on-chronic liver failure. Physiol Meas 2018; 39:114008. [PMID: 30475741 DOI: 10.1088/1361-6579/aaea10] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The network of interactions between different organs is impaired in liver cirrhosis. Liver cirrhosis is associated with multi-system involvement, which eventually leads to multiple organ failure. This process is accelerated by a precipitating factor such as bacterial infection, which leads to respiratory distress, circulatory shock, neural dysfunction and very high mortality. Cirrhotic patients often have blunted respiratory sinus arrhythmia and impaired cardio-respiratory variability. Fractal-like mechanical ventilation is reported to enhance respiratory sinus arrhythmia and attenuate respiratory distress in experimental models. In the present study we hypothesise that fractal-like mechanical ventilation may improve the outcome of cirrhotic rats with multiple organ failure. APPROACH Cirrhosis was induced by chronic biliary obstruction in rats. Acute multiple organ failure was induced by intraperitoneal injection of bacterial endotoxin in cirrhotic rats. The effect of conventional mechanical ventilation (with constant tidal volume and respiratory rate) or fractal-like ventilation (with the same average but variable tidal volume and respiratory rate) were assessed on vital signs, oxygen saturation and plasma alanine aminotransferase in anaesthetised cirrhotic rats. MAIN RESULTS We demonstrated that fractal-like mechanical ventilation was accompanied by improved oxygen saturation, reduced heart rate and decreased liver injury following injection of bacterial endotoxin. Moreover, variable mechanical ventilation in cirrhotic rats reduced mortality and prevented a fall in short-term heart rate variability following endotoxin challenge in comparison with rats with constant mechanical ventilation. SIGNIFICANCE We suggest further investigations into the beneficial effects of fractal-like ventilation strategy in critically ill patients with liver failure requiring organ support and mechanical ventilation.
Collapse
Affiliation(s)
- Arman Nataj
- Faculty of Medical Sciences, Department of Physiology, Tarbiat Modares University, Tehran, Iran. These authors are joint first authors
| | | | | | | |
Collapse
|
9
|
Walesa M, Bayat S, Albu G, Baudat A, Petak F, Habre W. Comparison between neurally-assisted, controlled, and physiologically variable ventilation in healthy rabbits. Br J Anaesth 2018; 121:918-927. [DOI: 10.1016/j.bja.2018.01.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 01/08/2018] [Accepted: 01/25/2018] [Indexed: 10/17/2022] Open
|
10
|
Camilo LM, Motta-Ribeiro GC, de Ávila MB, Paula LFSC, de Abreu MB, Carvalho AR, Zin WA. Variable Ventilation Associated With Recruitment Maneuver Minimizes Tissue Damage and Pulmonary Inflammation in Anesthetized Lung-Healthy Rats. Anesth Analg 2018; 127:784-791. [DOI: 10.1213/ane.0000000000003582] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
11
|
Multifractality, Interactivity, and the Adaptive Capacity of the Human Movement System: A Perspective for Advancing the Conceptual Basis of Neurologic Physical Therapy. J Neurol Phys Ther 2018; 41:245-251. [PMID: 28834791 DOI: 10.1097/npt.0000000000000199] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
BACKGROUND AND PURPOSE Physical therapists seek to optimize movement as a means of reducing disability and improving health. The short-term effects of interventions designed to optimize movement ultimately are intended to be adapted for use across various future patterns of behavior, in potentially unpredictable ways, with varying frequency, and in the context of multiple tasks and environmental conditions. In this perspective article, we review and discuss the implications of recent evidence that optimal movement variability, which previously had been associated with adaptable motor behavior, contains a specific complex nonlinear feature known as "multifractality." SUMMARY OF KEY POINTS Multifractal movement fluctuation patterns reflect robust physiologic interactivity occurring within the movement system across multiple time scales. Such patterns provide conceptual support for the idea that patterns of motor behavior occurring in the moment are inextricably linked in complex, physiologic ways to patterns of motor behavior occurring over much longer periods. The human movement system appears to be particularly tuned to multifractal fluctuation patterns and exhibits the ability to reorganize its output in response to external stimulation embedded with multifractal features. RECOMMENDATIONS FOR CLINICAL PRACTICE As a fundamental feature of human movement, multifractality opens new avenues for conceptualizing the link between physiologic interactivity and adaptive capacity. Preliminary evidence supporting the positive influence of multifractal rhythmic auditory stimulation on the gait patterns of individuals with Parkinson disease is used to illustrate how physical therapy interventions might be devised to specifically target the adaptive capacity of the human movement system.Video Abstract available for more insights from the authors (see Video, Supplemental Digital Content 1, http://links.lww.com/JNPT/A183).
Collapse
|
12
|
Güldner A, Huhle R, Beda A, Kiss T, Bluth T, Rentzsch I, Kerber S, Carvalho NC, Kasper M, Pelosi P, de Abreu MG. Periodic Fluctuation of Tidal Volumes Further Improves Variable Ventilation in Experimental Acute Respiratory Distress Syndrome. Front Physiol 2018; 9:905. [PMID: 30050467 PMCID: PMC6052143 DOI: 10.3389/fphys.2018.00905] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 06/21/2018] [Indexed: 11/28/2022] Open
Abstract
In experimental acute respiratory distress syndrome (ARDS), random variation of tidal volumes (VT) during volume controlled ventilation improves gas exchange and respiratory system mechanics (so-called stochastic resonance hypothesis). It is unknown whether those positive effects may be further enhanced by periodic VT fluctuation at distinct frequencies, also known as deterministic frequency resonance. We hypothesized that the positive effects of variable ventilation on lung function may be further amplified by periodic VT fluctuation at specific frequencies. In anesthetized and mechanically ventilated pigs, severe ARDS was induced by saline lung lavage and injurious VT (double-hit model). Animals were then randomly assigned to 6 h of protective ventilation with one of four VT patterns: (1) random variation of VT (WN); (2) P04, main VT frequency of 0.13 Hz; (3) P10, main VT frequency of 0.05 Hz; (4) VCV, conventional non-variable volume controlled ventilation. In groups with variable VT, the coefficient of variation was identical (30%). We assessed lung mechanics and gas exchange, and determined lung histology and inflammation. Compared to VCV, WN, P04, and P10 resulted in lower respiratory system elastance (63 ± 13 cm H2O/L vs. 50 ± 14 cm H2O/L, 48.4 ± 21 cm H2O/L, and 45.1 ± 5.9 cm H2O/L respectively, P < 0.05 all), but only P10 improved PaO2/FIO2 after 6 h of ventilation (318 ± 96 vs. 445 ± 110 mm Hg, P < 0.05). Cycle-by-cycle analysis of lung mechanics suggested intertidal recruitment/de-recruitment in P10. Lung histologic damage and inflammation did not differ among groups. In this experimental model of severe ARDS, periodic VT fluctuation at a frequency of 0.05 Hz improved oxygenation during variable ventilation, suggesting that deterministic resonance adds further benefit to variable ventilation.
Collapse
Affiliation(s)
- Andreas Güldner
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Robert Huhle
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Alessandro Beda
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Departamento de Engenharia Eletrônica, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Thomas Kiss
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Thomas Bluth
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Ines Rentzsch
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Department of Orthodontics, Technische Universität Dresden, Dresden, Germany
| | - Sarah Kerber
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Nadja C Carvalho
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Departamento de Engenharia Eletrônica, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Michael Kasper
- Institute of Anatomy, Technische Universität Dresden, Dresden, Germany
| | - Paolo Pelosi
- Department of Surgical Sciences and Integrated Diagnostics, IRCCS San Martino IST, University of Genoa, Genoa, Italy
| | - Marcelo G de Abreu
- Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
13
|
Thungtong A, Knoch MF, Jacono FJ, Dick TE, Loparo KA. Periodicity: A Characteristic of Heart Rate Variability Modified by the Type of Mechanical Ventilation After Acute Lung Injury. Front Physiol 2018; 9:772. [PMID: 29971020 PMCID: PMC6018479 DOI: 10.3389/fphys.2018.00772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 06/04/2018] [Indexed: 11/16/2022] Open
Abstract
We present a novel approach to quantify heart rate variability (HRV) and the results of applying this approach to synthetic and original data sets. Our approach evaluates the periodicity of heart rate by calculating the transform of Relative Shannon Entropy, the maximum value of the RR interval periodogram, and the maximum, mean values, and sample entropy of the autocorrelation function. Synthetic data were generated using a Van der Pol oscillator; and the original data were electrocardiogram (ECG) recordings from anesthetized rats after acute lung injury while on biologically variable (BVV) or continuous mechanical ventilation (CMV). Analysis of the synthetic data revealed that our measures were correlated highly to the bandwidth of the oscillator and assessed periodicity. Then, applying these analytical tools to the ECGs determined that the heart rate (HR) of BVV group had less periodicity and higher variability than the HR of the CMV group. Quantifying periodicity effectively identified a readily apparent difference in HRV during BVV and CMV that was not identified by power spectral density measures during BVV and CMV. Cardiorespiratory coupling is the probable mechanism for HRV increasing during BVV and becoming periodic during CMV. Thus, the absence or presence of periodicity in ventilation determined HRV, and this mechanism is distinctly different from the cardiorespiratory uncoupling that accounts for the loss of HRV during sepsis.
Collapse
Affiliation(s)
- Anurak Thungtong
- School of Engineering and Resources, Walailak University, Nakhon Si Thammarat, Thailand.,Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH, United States
| | - Matthew F Knoch
- Division of Pulmonary, Critical Care & Sleep Medicine, Department of Medicine, University Hospitals Cleveland Medical Center (UHCMC), Cleveland, OH, United States
| | - Frank J Jacono
- Division of Pulmonary, Critical Care & Sleep Medicine, Department of Medicine, University Hospitals Cleveland Medical Center (UHCMC), Cleveland, OH, United States.,Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States
| | - Thomas E Dick
- Division of Pulmonary, Critical Care & Sleep Medicine, Department of Medicine, University Hospitals Cleveland Medical Center (UHCMC), Cleveland, OH, United States.,Department of Neurosciences, Case Western Reserve University, Cleveland, OH, United States
| | - Kenneth A Loparo
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH, United States
| |
Collapse
|
14
|
Fontela PC, Prestes RB, Forgiarini LA, Friedman G. Variable mechanical ventilation. Rev Bras Ter Intensiva 2018; 29:77-86. [PMID: 28444076 PMCID: PMC5385989 DOI: 10.5935/0103-507x.20170012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2016] [Accepted: 08/18/2016] [Indexed: 11/20/2022] Open
Abstract
Objective To review the literature on the use of variable mechanical ventilation and
the main outcomes of this technique. Methods Search, selection, and analysis of all original articles on variable
ventilation, without restriction on the period of publication and language,
available in the electronic databases LILACS, MEDLINE®,
and PubMed, by searching the terms "variable ventilation" OR "noisy
ventilation" OR "biologically variable ventilation". Results A total of 36 studies were selected. Of these, 24 were original studies,
including 21 experimental studies and three clinical studies. Conclusion Several experimental studies reported the beneficial effects of distinct
variable ventilation strategies on lung function using different models of
lung injury and healthy lungs. Variable ventilation seems to be a viable
strategy for improving gas exchange and respiratory mechanics and preventing
lung injury associated with mechanical ventilation. However, further
clinical studies are necessary to assess the potential of variable
ventilation strategies for the clinical improvement of patients undergoing
mechanical ventilation.
Collapse
Affiliation(s)
- Paula Caitano Fontela
- Programa de Pós-Graduação em Ciências Pneumológicas, Universidade Federal do Rio Grande do Sul - Porto Alegre (RS), Brasil
| | - Renata Bernardy Prestes
- Curso de Mestrado Acadêmico em Biociências e Reabilitação, Centro Universitário Metodista IPA - Porto Alegre (RS), Brasil
| | - Luiz Alberto Forgiarini
- Programa de Pós-Graduação em Biociências e Reabilitação e Reabilitação e Inclusão, Centro Universitário Metodista IPA - Porto Alegre (RS), Brasil
| | - Gilberto Friedman
- Programa de Pós-Graduação em Ciências Pneumológicas, Faculdade de Medicina, Universidade Federal do Rio Grande do Sul - Porto Alegre (RS), Brasil
| |
Collapse
|
15
|
Spieth P, Güldner A, Uhlig C, Bluth T, Kiss T, Conrad C, Bischlager K, Braune A, Huhle R, Insorsi A, Tarantino F, Ball L, Schultz M, Abolmaali N, Koch T, Pelosi P, Gama de Abreu M. Variable versus conventional lung protective mechanical ventilation during open abdominal surgery (PROVAR): a randomised controlled trial. Br J Anaesth 2018; 120:581-591. [DOI: 10.1016/j.bja.2017.11.078] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 07/31/2017] [Accepted: 09/18/2017] [Indexed: 10/18/2022] Open
|
16
|
Rentzsch I, Santos CL, Huhle R, Ferreira JMC, Koch T, Schnabel C, Koch E, Pelosi P, Rocco PRM, Gama de Abreu M. Variable stretch reduces the pro-inflammatory response of alveolar epithelial cells. PLoS One 2017; 12:e0182369. [PMID: 28813446 PMCID: PMC5557541 DOI: 10.1371/journal.pone.0182369] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 07/17/2017] [Indexed: 11/18/2022] Open
Abstract
Mechanical ventilation has the potential to increase inflammation in both healthy and injured lungs. Several animal studies have shown that variable ventilation recruits the lungs and reduces inflammation. However, it is unclear which cellular mechanisms are involved in those findings. We hypothesized that variable stretch of LPS-stimulated alveolar epithelial cells (AECs) reduces the production of pro-inflammatory cytokines compared to non-variable stretch. AECs were subjected to non-variable or variable cyclic stretch (sinusoidal pattern), with and without LPS stimulation. The expression and release of interleukin-6, CXCL-2 and CCL-2 mRNA were analyzed after 4 hours. The phosphorylation of the MAPKs ERK1/2 and SAPK/JNK was determined by Western Blot analysis at 0, 15, 30, 45 and 60 min of cyclic stretch. In LPS-stimulated AECs, variable cyclic cell stretching led to reduced cytokine expression and release compared to non-variable cell stretching. Furthermore, the phosphorylation of the MAPK ERK1/2 was increased after 30 minutes in non-variable stretched AECs, whereas variable stretched cells demonstrated only the non-stretched level of phosphorylation. After the 4h period of cyclic cell stretch and inhibition of the ERK1/2, but not the SAPK/JNK, signaling pathway, the gene expression of investigated cytokines increased in variable stretched, and decreased in non-variable stretched AECs. We conclude that in LPS-stimulated AECs, variable stretch reduced the pro-inflammatory response compared to non-variable stretch. This effect was mediated by the ERK1/2 signaling pathway, and might partly explain the findings of reduced lung inflammation during mechanical ventilation modes that enhance breath-by-breath variability of the respiratory pattern.
Collapse
Affiliation(s)
- Ines Rentzsch
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Cíntia L. Santos
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Robert Huhle
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Jorge M. C. Ferreira
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Thea Koch
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Christian Schnabel
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Edmund Koch
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Paolo Pelosi
- Department of Surgical Sciences and Integrated Diagnostics, AOU IRCCS San Martino –IST, University of Genoa, Genoa, Italy
| | - Patricia R. M. Rocco
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Marcelo Gama de Abreu
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
- * E-mail:
| |
Collapse
|
17
|
Suki B, Parameswaran H, Imsirovic J, Bartolák-Suki E. Regulatory Roles of Fluctuation-Driven Mechanotransduction in Cell Function. Physiology (Bethesda) 2017; 31:346-58. [PMID: 27511461 DOI: 10.1152/physiol.00051.2015] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Cells in the body are exposed to irregular mechanical stimuli. Here, we review the so-called fluctuation-driven mechanotransduction in which stresses stretching cells vary on a cycle-by-cycle basis. We argue that such mechanotransduction is an emergent network phenomenon and offer several potential mechanisms of how it regulates cell function. Several examples from the vasculature, the lung, and tissue engineering are discussed. We conclude with a list of important open questions.
Collapse
Affiliation(s)
- Béla Suki
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts
| | | | - Jasmin Imsirovic
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts
| | | |
Collapse
|
18
|
Abstract
This article is one of ten reviews selected from the Annual Update in Intensive Care and Emergency medicine 2016. Other selected articles can be found online at http://www.biomedcentral.com/collections/annualupdate2016. Further information about the Annual Update in Intensive Care and Emergency Medicine is available from http://www.springer.com/series/8901.
Collapse
Affiliation(s)
- Robert Huhle
- Pulmonary Engineering Group, Department of Anaesthesiology and Intensive Care Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Paolo Pelosi
- University of Genoa, Department of Surgical Sciences and Integrated Diagnostics, IRCCS AOU San Martino IST, 16131, Genoa, Italy.
| | - Marcelo Gama de Abreu
- Pulmonary Engineering Group, Department of Anaesthesiology and Intensive Care Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
19
|
Camilo LM, Ávila MB, Cruz LFS, Ribeiro GCM, Spieth PM, Reske AA, Amato M, Giannella-Neto A, Zin WA, Carvalho AR. Positive end-expiratory pressure and variable ventilation in lung-healthy rats under general anesthesia. PLoS One 2014; 9:e110817. [PMID: 25383882 PMCID: PMC4226529 DOI: 10.1371/journal.pone.0110817] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Accepted: 09/13/2014] [Indexed: 11/25/2022] Open
Abstract
Objectives Variable ventilation (VV) seems to improve respiratory function in acute lung injury and may be combined with positive end-expiratory pressure (PEEP) in order to protect the lungs even in healthy subjects. We hypothesized that VV in combination with moderate levels of PEEP reduce the deterioration of pulmonary function related to general anesthesia. Hence, we aimed at evaluating the alveolar stability and lung protection of the combination of VV at different PEEP levels. Design Randomized experimental study. Setting Animal research facility. Subjects Forty-nine male Wistar rats (200–270 g). Interventions Animals were ventilated during 2 hours with protective low tidal volume (VT) in volume control ventilation (VCV) or VV and PEEP adjusted at the level of minimum respiratory system elastance (Ers), obtained during a decremental PEEP trial subsequent to a recruitment maneuver, and 2 cmH2O above or below of this level. Measurements and Main Results Ers, gas exchange and hemodynamic variables were measured. Cytokines were determined in lung homogenate and plasma samples and left lung was used for histologic analysis and diffuse alveolar damage scoring. A progressive time-dependent increase in Ers was observed independent on ventilatory mode or PEEP level. Despite of that, the rate of increase of Ers and lung tissue IL-1 beta concentration were significantly lower in VV than in VCV at the level of the PEEP of minimum Ers. A significant increase in lung tissue cytokines (IL-6, IL-1 beta, CINC-1 and TNF-alpha) as well as a ventral to dorsal and cranial to caudal reduction in aeration was observed in all ventilated rats with no significant differences among groups. Conclusions VV combined with PEEP adjusted at the level of the PEEP of minimal Ers seemed to better prevent anesthesia-induced atelectasis and might improve lung protection throughout general anesthesia.
Collapse
Affiliation(s)
- Luciana M. Camilo
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Mariana B. Ávila
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Luis Felipe S. Cruz
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Gabriel C. M. Ribeiro
- Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luis Coimbra Institute of Post-Graduation and Research in Engineering, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Peter M. Spieth
- Pulmonary Engineering Group, Department of Anesthesiology and Intensive Care Medicine, Technische Universität Dresden, Germany
| | - Andreas A. Reske
- Department of Anesthesiology and Intensive Care Medicine, University of Leipzig, Leipzig, Germany
| | - Marcelo Amato
- Cardio-Pulmonary Department, Pulmonary Division, Hospital das Clínicas, Universidade de São Paulo, São Paulo, Brazil
| | - Antonio Giannella-Neto
- Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luis Coimbra Institute of Post-Graduation and Research in Engineering, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Walter A. Zin
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Alysson R. Carvalho
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
- Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luis Coimbra Institute of Post-Graduation and Research in Engineering, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
- * E-mail:
| |
Collapse
|
20
|
Huhle R, Spieth PM, Güldner A, Koch T, Abreu MGD. A new adaptive controller for volume-controlled mechanical ventilation in small animals. Exp Lung Res 2014; 40:186-97. [DOI: 10.3109/01902148.2014.900156] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
21
|
Abstract
Mechanical ventilation of patients with acute respiratory distress syndrome (ARDS) is a necessary life support measure which may lead to ventilator-induced lung injury, a complication that can be reduced or ameliorated by using appropriate tidal volumes and positive end-expiratory pressures. However, the optimal mechanical ventilation parameters are almost certainly different for each patient, and will vary with time as the injury status of the lung changes. In order to optimize mechanical ventilation in an individual ARDS patient, therefore, it is necessary to track the manner in which injury status is reflected in the mechanical properties of the lungs. Accordingly, we developed an algorithm for assessing the time-dependent manner in which different lung regions open (recruit) and close (derecruit) as a function of the pressure waveform that is applied to the airways during mechanical ventilation. We used this algorithm to test the notion that variable ventilation provides the dynamic perturbations in lung volume necessary to accurately identify recruitment/derecruitment dynamics in the injured lung. We performed this test on synthetic pressure and flow data generated with established numerical models of lung function corresponding to both healthy mice and mice with lung injury. The data were generated by subjecting the models to a variety of mechanical ventilation regimens including variable ventilation. Our results support the hypothesis that variable ventilation can be used as a diagnostic tool to identify the injury status of the lung in ARDS.
Collapse
|
22
|
Baudin F, Wu HT, Bordessoule A, Beck J, Jouvet P, Frasch MG, Emeriaud G. Impact of ventilatory modes on the breathing variability in mechanically ventilated infants. Front Pediatr 2014; 2:132. [PMID: 25505779 PMCID: PMC4242927 DOI: 10.3389/fped.2014.00132] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Accepted: 11/10/2014] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Reduction of breathing variability is associated with adverse outcome. During mechanical ventilation, the variability of ventilatory pressure is dependent on the ventilatory mode. During neurally adjusted ventilatory assist (NAVA), the support is proportional to electrical activity of the diaphragm (EAdi), which reflects the respiratory center output. The variability of EAdi is, therefore, translated into a similar variability in pressures. Contrastingly, conventional ventilatory modes deliver less variable pressures. The impact of the mode on the patient's own respiratory drive is less clear. This study aims to compare the impact of NAVA, pressure-controlled ventilation (PCV), and pressure support ventilation (PSV) on the respiratory drive patterns in infants. We hypothesized that on NAVA, EAdi variability resembles most of the endogenous respiratory drive pattern seen in a control group. METHODS Electrical activity of the diaphragm was continuously recorded in 10 infants ventilated successively on NAVA (5 h), PCV (30 min), and PSV (30 min). During the last 10 min of each period, the EAdi variability pattern was assessed using non-rhythmic to rhythmic (NRR) index. These variability profiles were compared to the pattern of a control group of 11 spontaneously breathing and non-intubated infants. RESULTS In control infants, NRR was higher as compared to mechanically ventilated infants (p < 0.001), and NRR pattern was relatively stable over time. While the temporal stability of NRR was similar in NAVA and controls, the NRR profile was less stable during PCV. PSV exhibited an intermediary pattern. PERSPECTIVES Mechanical ventilation impacts the breathing variability in infants. NAVA produces EAdi pattern resembling most that of control infants. NRR can be used to characterize respiratory variability in infants. Larger prospective studies are necessary to understand the differential impact of the ventilatory modes on the cardio-respiratory variability and to study their impact on clinical outcomes.
Collapse
Affiliation(s)
- Florent Baudin
- Department of Pediatrics, CHU Sainte-Justine, Université de Montréal , Montreal, QC , Canada
| | - Hau-Tieng Wu
- Department of Mathematics, University of Toronto , Toronto, ON , Canada
| | - Alice Bordessoule
- Pediatric Critical Care Unit, Geneva University Hospital , Geneva , Switzerland
| | - Jennifer Beck
- Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, St. Michael's Hospital , Toronto, ON , Canada ; Department of Pediatrics, University of Toronto , Toronto, ON , Canada
| | - Philippe Jouvet
- Department of Pediatrics, CHU Sainte-Justine, Université de Montréal , Montreal, QC , Canada
| | - Martin G Frasch
- Department of Obstetrics and Gynecology, CHU Ste-Justine Research Center, Université de Montréal , Montreal, QC , Canada ; Department of Neurosciences, CHU Ste-Justine Research Center, Université de Montréal , Montreal, QC , Canada ; Centre de recherche en reproduction animale, Université de Montréal , St-Hyacinthe, QC , Canada
| | - Guillaume Emeriaud
- Department of Pediatrics, CHU Sainte-Justine, Université de Montréal , Montreal, QC , Canada
| |
Collapse
|
23
|
Abstract
This article describes the gas exchange abnormalities occurring in the acute respiratory distress syndrome seen in adults and children and in the respiratory distress syndrome that occurs in neonates. Evidence is presented indicating that the major gas exchange abnormality accounting for the hypoxemia in both conditions is shunt, and that approximately 50% of patients also have lungs regions in which low ventilation-to-perfusion ratios contribute to the venous admixture. The various mechanisms by which hypercarbia may develop and by which positive end-expiratory pressure improves gas exchange are reviewed, as are the effects of vascular tone and airway narrowing. The mechanisms by which surfactant abnormalities occur in the two conditions are described, as are the histological findings that have been associated with shunt and low ventilation-to-perfusion.
Collapse
Affiliation(s)
- Richard K Albert
- Chief of Medicine, Denver Health, Professor of Medicine, University of Colorado, Adjunct Professor of Engineering and Computer Science, University of Denver, Denver, Colorado, USA.
| | | |
Collapse
|
24
|
Tobin MJ, Laghi F, Jubran A. Ventilatory failure, ventilator support, and ventilator weaning. Compr Physiol 2013; 2:2871-921. [PMID: 23720268 DOI: 10.1002/cphy.c110030] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The development of acute ventilatory failure represents an inability of the respiratory control system to maintain a level of respiratory motor output to cope with the metabolic demands of the body. The level of respiratory motor output is also the main determinant of the degree of respiratory distress experienced by such patients. As ventilatory failure progresses and patient distress increases, mechanical ventilation is instituted to help the respiratory muscles cope with the heightened workload. While a patient is connected to a ventilator, a physician's ability to align the rhythm of the machine with the rhythm of the patient's respiratory centers becomes the primary determinant of the level of rest accorded to the respiratory muscles. Problems of alignment are manifested as failure to trigger, double triggering, an inflationary gas-flow that fails to match inspiratory demands, and an inflation phase that persists after a patient's respiratory centers have switched to expiration. With recovery from disorders that precipitated the initial bout of acute ventilatory failure, attempts are made to discontinue the ventilator (weaning). About 20% of weaning attempts fail, ultimately, because the respiratory controller is unable to sustain ventilation and this failure is signaled by development of rapid shallow breathing. Substantial advances in the medical management of acute ventilatory failure that requires ventilator assistance are most likely to result from research yielding novel insights into the operation of the respiratory control system.
Collapse
Affiliation(s)
- Martin J Tobin
- Division of Pulmonary and Critical Care Medicine, Edward Hines Jr. Veterans Affairs Hospital and Loyola University of Chicago Stritch School of Medicine, Hines, Illinois, USA.
| | | | | |
Collapse
|
25
|
|
26
|
Variable ventilation enhances ventilation without exacerbating injury in preterm lambs with respiratory distress syndrome. Pediatr Res 2012; 72:384-92. [PMID: 22805999 DOI: 10.1038/pr.2012.97] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND As compared with constant respiratory rate (RR) and tidal volume (V(T)) during controlled conventional mechanical ventilation (CV), variable ventilation (VV) using the same breath-to-breath minute volume but variable V(T) and RRs enhances ventilation efficiency in preterm lambs. We hypothesized that if V(T) was adjusted to target permissive hypercarbia, VV would result in more efficient gas exchange without increasing inflammatory and injurious responses in the lung. METHODS Preterm lambs at 129 d gestation were anesthetized, tracheotomized, and randomized to either CV (n = 8) or VV (n = 8) using the same initial average V(T) and RR. Lung mechanics and gas exchange were measured intermittently, and average V(T) was adjusted to target partial pressure of arterial carbon dioxide (PaCO2) of 40-50 mm Hg for 3 h. Lung injury and inflammation were assessed from bronchoalveolar lavage fluid, lung tissue, and peripheral blood. RESULTS VV achieved permissive hypercarbia using a lower average V(T), peak inspiratory pressure, and elastance (increased compliance) as compared with CV. Oxygenation and markers of lung tissue inflammation or injury were not different apart from a lower wet:dry tissue ratio in the VV lungs. CONCLUSIONS VV improves ventilation efficiency and in vivo lung compliance in the ovine preterm lung without increasing lung inflammation or lung injury.
Collapse
|
27
|
Albert RK. The role of ventilation-induced surfactant dysfunction and atelectasis in causing acute respiratory distress syndrome. Am J Respir Crit Care Med 2012; 185:702-8. [PMID: 22227381 DOI: 10.1164/rccm.201109-1667pp] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
This Pulmonary Perspective describes a new pathophysiologic scenario by which the acute respiratory distress syndrome (ARDS) might develop, summarizes the literature on which this new scenario is based, and discusses the resulting implications with respect to patient management. Rather than ARDS occurring as a result of the inflammatory response associated with predisposing risk factors, the proposed scenario theorizes that the initiating problem is atelectasis that develops as a result of a surfactant abnormality that is caused by spontaneous or mechanical ventilation, together with our current approaches to patient positioning and sedation. The proposed pathophysiology implies that ventilation-induced lung injury occurs before, and causes, ARDS (rather than developing after the fact and only serving to magnify the existing injury) and that some instances of ARDS are iatrogenic. If the proposed scenario is correct, it also implies that at least some instances of ARDS might be prevented by implementing a number of simple, safe modifications in patient care.
Collapse
Affiliation(s)
- Richard K Albert
- Department of Medicine, Denver Health, Denver, Colorado 80204-4507, USA.
| |
Collapse
|
28
|
Quantitative computed tomography in porcine lung injury with variable versus conventional ventilation: Recruitment and surfactant replacement*. Crit Care Med 2011; 39:1721-30. [DOI: 10.1097/ccm.0b013e3182186d09] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
29
|
Resolution of pulmonary edema with variable mechanical ventilation in a porcine model of acute lung injury. Can J Anaesth 2011; 58:740-50. [DOI: 10.1007/s12630-011-9517-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2010] [Accepted: 05/10/2011] [Indexed: 12/20/2022] Open
|
30
|
Pillow JJ, Musk GC, McLean CM, Polglase GR, Dalton RGB, Jobe AH, Suki B. Variable ventilation improves ventilation and lung compliance in preterm lambs. Intensive Care Med 2011; 37:1352-9. [DOI: 10.1007/s00134-011-2237-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2010] [Accepted: 02/23/2011] [Indexed: 11/29/2022]
|
31
|
Spontaneously regulated vs. controlled ventilation of acute lung injury/acute respiratory distress syndrome. Curr Opin Crit Care 2011; 17:24-9. [PMID: 21157317 DOI: 10.1097/mcc.0b013e328342726e] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE OF REVIEW To present an updated discussion of those aspects of controlled positive pressure breathing and retained spontaneous regulation of breathing that impact the management of patients whose tissue oxygenation is compromised by acute lung injury. RECENT FINDINGS The recent introduction of ventilation techniques geared toward integrating natural breathing rhythms into even the earliest phase of acute respiratory distress syndrome support (e.g., airway pressure release, proportional assist ventilation, and neurally adjusted ventilatory assist), has stimulated a burst of new investigations. SUMMARY Optimizing gas exchange, avoiding lung injury, and preserving respiratory muscle strength and endurance are vital therapeutic objectives for managing acute lung injury. Accordingly, comparing the physiology and consequences of breathing patterns that preserve and eliminate breathing effort has been a theme of persisting investigative interest throughout the several decades over which it has been possible to sustain cardiopulmonary life support outside the operating theater.
Collapse
|
32
|
Ma B, Suki B, Bates JHT. Effects of recruitment/derecruitment dynamics on the efficacy of variable ventilation. J Appl Physiol (1985) 2011; 110:1319-26. [PMID: 21372101 DOI: 10.1152/japplphysiol.01364.2010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Variable (or noisy) ventilation (VV) has been demonstrated in animal models of acute lung injury to be superior to constant (or conventional) ventilation (CV), in terms of improved gas exchange and mitigation of lung injury, for reasons that are not entirely clear. We hypothesized that the efficacy of VV is related to the fact that recruitment and derecruitment of lung units are dynamic processes. To test this hypothesis, we modeled the lung computationally as a symmetrically bifurcating airway tree terminating in elastic units. Each airway was fully open or completely closed, at any point in time, according to its pressure history. The model is able to accurately mimic previous experimental measurements showing that the lungs of mice injured by acid aspiration are better recruited after 60 min of VV than CV. The model also shows that recruitment/derecruitment dynamics contribute to the relative efficacy of VV, provided lung units open more rapidly than they close once a critical opening or closing pressure threshold has been crossed. We conclude that the dynamics of recruitment and derecruitment in the lung may be important factors responsible for the benefits of VV compared with CV.
Collapse
Affiliation(s)
- Baoshun Ma
- Vermont Lung Center, Department of Medicine, University of Vermont College of Medicine, Burlington, VT 05405, USA
| | | | | |
Collapse
|
33
|
Interrelations entre ventilation mécanique et système nerveux autonome. MEDECINE INTENSIVE REANIMATION 2011. [DOI: 10.1007/s13546-011-0218-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
34
|
Lower interbreath interval complexity is associated with extubation failure in mechanically ventilated patients during spontaneous breathing trials. ACTA ACUST UNITED AC 2010; 68:1310-6. [PMID: 20539175 DOI: 10.1097/ta.0b013e3181da90db] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To determine whether lower complexity of interbreath interval as measured with nonlinear analysis techniques will identify patients who fail to separate from mechanical ventilation after 30-minute spontaneous breathing trials (SBTs). METHODS Respiratory waveforms from SBT of patients in surgical or burn intensive care units were recorded for later analysis. The decision to extubate was made by attending physician. Extubated patients were observed for 48 hours; during this time, reintubation or noninvasive positive pressure ventilation was considered as a failure. Analysis of waveform data by software was performed post hoc. Sample entropy (SampEn) and other nonlinear measures were 48 hours of extubation. RESULTS Thirty-two patients (24 burn, 8 trauma/surgical admissions; mean age, 40.2 +/- 16.9 years; 26 men and 6 women) who were intubated >24 hours were extubated after SBT. Twenty-four patients were successfully separated from mechanical ventilation and eight failed. Age, gender, and mechanism of injury did not influence outcome. SampEn calculated for the two groups presented in this study was different with the cohort that failed extubation having a lower mean value (1.35 +/- 0.39 vs. 1.87 +/- 0.27; p < 0.001). Other nonlinear metrics were moved in concert with SampEn. The stationarity in the respiratory signal was not different between groups. CONCLUSION In intubated patients, the interbreath interval in those who were successfully separated from mechanical ventilation was more irregular than those who failed, as measured by nonlinear techniques. When available at bedside, these metrics may be useful markers of pulmonary health and assist in clinical decision making.
Collapse
|
35
|
|
36
|
Beda A, Spieth PM, Handzsuj T, Pelosi P, Carvalho NC, Koch E, Koch T, Gama de Abreu M. A novel adaptive control system for noisy pressure-controlled ventilation: a numerical simulation and bench test study. Intensive Care Med 2009; 36:164-8. [PMID: 19779696 DOI: 10.1007/s00134-009-1665-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2009] [Accepted: 07/21/2009] [Indexed: 10/20/2022]
Abstract
PURPOSE There is growing interest in the use of both variable and pressure-controlled ventilation (PCV). The combination of these approaches as "noisy PCV" requires adaptation of the mechanical ventilator to the respiratory system mechanics. Thus, we developed and evaluated a new control system based on the least-mean-squares adaptive approach, which automatically and continuously adjusts the driving pressure during PCV to achieve the desired variability pattern of tidal volume (V (T)). METHODS The controller was tested during numerical simulations and with a physical model reproducing the mechanical properties of the respiratory system. We applied step changes in respiratory system mechanics and mechanical ventilation settings. The time needed to converge to the desired V (T) variability pattern after each change (t (c)) and the difference in minute ventilation between the measured and target pattern of V (T) (DeltaMV) were determined. RESULTS During numerical simulations, the control system for noisy PCV achieved the desired variable V (T) pattern in less than 30 respiratory cycles, with limited influence of the dynamic elastance (E*) on t (c), except when E* was underestimated by >25%. We also found that, during tests in the physical model, the control system converged in <60 respiratory cycles and was not influenced by airways resistance. In all measurements, the absolute value of DeltaMV was <25%. CONCLUSION The new control system for noisy PCV can prove useful for controlled mechanical ventilation in the intensive care unit.
Collapse
Affiliation(s)
- Alessandro Beda
- Department of Anesthesiology and Intensive Care Therapy, University Hospital Dresden, Dresden, Germany
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Spieth PM, Carvalho AR, Pelosi P, Hoehn C, Meissner C, Kasper M, Hübler M, von Neindorff M, Dassow C, Barrenschee M, Uhlig S, Koch T, de Abreu MG. Variable tidal volumes improve lung protective ventilation strategies in experimental lung injury. Am J Respir Crit Care Med 2009; 179:684-93. [PMID: 19151194 DOI: 10.1164/rccm.200806-975oc] [Citation(s) in RCA: 117] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
RATIONALE Noisy ventilation with variable Vt may improve respiratory function in acute lung injury. OBJECTIVES To determine the impact of noisy ventilation on respiratory function and its biological effects on lung parenchyma compared with conventional protective mechanical ventilation strategies. METHODS In a porcine surfactant depletion model of lung injury, we randomly combined noisy ventilation with the ARDS Network protocol or the open lung approach (n = 9 per group). MEASUREMENTS AND MAIN RESULTS Respiratory mechanics, gas exchange, and distribution of pulmonary blood flow were measured at intervals over a 6-hour period. Postmortem, lung tissue was analyzed to determine histological damage, mechanical stress, and inflammation. We found that, at comparable minute ventilation, noisy ventilation (1) improved arterial oxygenation and reduced mean inspiratory peak airway pressure and elastance of the respiratory system compared with the ARDS Network protocol and the open lung approach, (2) redistributed pulmonary blood flow to caudal zones compared with the ARDS Network protocol and to peripheral ones compared with the open lung approach, (3) reduced histological damage in comparison to both protective ventilation strategies, and (4) did not increase lung inflammation or mechanical stress. CONCLUSIONS Noisy ventilation with variable Vt and fixed respiratory frequency improves respiratory function and reduces histological damage compared with standard protective ventilation strategies.
Collapse
Affiliation(s)
- Peter M Spieth
- Department of Anesthesiology and Intensive Care Therapy, University Hospital Dresden, Fetscherstrasse 74, 01307 Dresden, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Gama de Abreu M, Spieth PM, Pelosi P. Variable Mechanical Ventilation: Breaking the Monotony. Intensive Care Med 2009. [DOI: 10.1007/978-0-387-92278-2_35] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
39
|
Physiological noise versus white noise to drive a variable ventilator in a porcine model of lung injury. Can J Anaesth 2008; 55:577-86. [DOI: 10.1007/bf03021431] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
40
|
Gebber GL, Barman SM. Variable rate ventilation strategies for the injured lung. Can J Anaesth 2008; 55:572-6. [DOI: 10.1007/bf03021430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
41
|
Thammanomai A, Hueser LE, Majumdar A, Bartolák-Suki E, Suki B. Design of a new variable-ventilation method optimized for lung recruitment in mice. J Appl Physiol (1985) 2008; 104:1329-40. [DOI: 10.1152/japplphysiol.01002.2007] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Variable ventilation (VV), characterized by breath-to-breath variation of tidal volume (Vt) and breathing rate (f), has been shown to improve lung mechanics and blood oxygenation during acute lung injury in many species compared with conventional ventilation (CV), characterized by constant Vt and f. During CV as well as VV, the lungs of mice tend to collapse over time; therefore, the goal of this study was to develop a new VV mode (VVN) with an optimized distribution of Vt to maximize recruitment. Groups of normal and HCl-injured mice were subjected to 1 h of CV, original VV (VVO), CV with periodic large breaths (CVLB), and VVN, and the effects of ventilation modes on respiratory mechanics, airway pressure, blood oxygenation, and IL-1β were assessed. During CV and VVO, normal and injured mice showed regional lung collapse with increased airway pressures and poor oxygenation. CVLB and VVN resulted in a stable dynamic equilibrium with significantly improved respiratory mechanics and oxygenation. Nevertheless, VVN provided a consistently better physiological response. In injured mice, VVO and VVN, but not CVLB, were able to reduce the IL-1β-related inflammatory response compared with CV. In conclusion, our results suggest that application of higher Vt values than the single Vt currently used in clinical situations helps stabilize lung function. In addition, variable stretch patterns delivered to the lung by VV can reduce the progression of lung injury due to ventilation in injured mice.
Collapse
|
42
|
Noisy pressure support ventilation: A pilot study on a new assisted ventilation mode in experimental lung injury*. Crit Care Med 2008; 36:818-27. [DOI: 10.1097/01.ccm.0000299736.55039.3a] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
43
|
|
44
|
Mutch WAC, Buchman TG, Girling LG, Walker EKY, McManus BM, Graham MR. Biologically variable ventilation improves gas exchange and respiratory mechanics in a model of severe bronchospasm*. Crit Care Med 2007; 35:1749-55. [PMID: 17522581 DOI: 10.1097/01.ccm.0000269039.61615.a1] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Mechanical ventilation can be lifesaving for status asthmaticus, but how best to accomplish mechanical ventilation is unclear. Biologically variable ventilation (mechanical ventilation that emulates healthy variation) and conventional control mode ventilation (monotonously regular) were compared in an animal model of bronchospasm to determine which approach yields better gas exchange and respiratory mechanics. DESIGN A randomized prospective trial of biologically variable ventilation vs. control mode ventilation in swine. SETTING University research laboratory. SUBJECTS Eighteen farm-raised pigs. INTERVENTIONS Methacholine was administered as a nebulized aerosol to initiate bronchospasm, defined as doubling of peak inspiratory pressure and respiratory system resistance, and then randomized (n = 9 each group) to either continue control mode ventilation or switch to biologically variable ventilation at the same minute ventilation. Over the next 4 hrs, hemodynamics, blood gases, respiratory mechanics, and carbon dioxide expirograms were recorded hourly. At end-experiment, tracheobronchial lavage was undertaken to determine interleukin-6 and -10 concentrations. MEASUREMENTS AND MAIN RESULTS Measurements of physiologic variables and inflammatory cytokines showed that biologically variable ventilation significantly improved gas exchange, with greater arterial oxygen tensions (p = .006; group x time interaction), lower arterial carbon dioxide tensions (p = .0003; group effect), lower peak inspiratory pressures (p = .0001; group x time), greater static compliance (p = .0001; group x time), greater dynamic compliance (p = .0001; group x time), and lower total respiratory system resistance (p = .028; group x time), compared with conventional ventilation. The appearance of inflammatory cytokines in bronchoalveolar lavage fluid (interleukin-6 and -10) was not affected by mode of ventilation. CONCLUSIONS In this experimental model, biologically variable ventilation was superior to control mode ventilation in terms of gas exchange and respiratory mechanics during severe bronchospasm.
Collapse
|
45
|
Abstract
Physiologic systems in health and disease display an extraordinary range of temporal behaviors and structural patterns that defy understanding based on linear constructs, reductionist strategies, and classical homeostasis. Application of concepts and computational tools derived from the contemporary study of complex systems, including nonlinear dynamics, fractals and "chaos theory," is having an increasing impact on biology and medicine. This presentation provides a brief overview of an emerging area of biomedical research, including recent applications to cardiopulmonary medicine and chronic obstructive lung disease.
Collapse
Affiliation(s)
- Ary L Goldberger
- Cardiology Division, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, GZ-435, Boston, MA 02215, USA.
| |
Collapse
|
46
|
Brewster JF, Graham MR, Mutch WAC. Convexity, Jensen's inequality and benefits of noisy mechanical ventilation. J R Soc Interface 2006; 2:393-6. [PMID: 16849198 PMCID: PMC1578266 DOI: 10.1098/rsif.2005.0043] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Mechanical ventilators breathe for you when you cannot or when your lungs are too sick to do their job. Most ventilators monotonously deliver the same-sized breaths, like clockwork; however, healthy people do not breathe this way. This has led to the development of a biologically variable ventilator--one that incorporates noise. There are indications that such a noisy ventilator may be beneficial for patients with very sick lungs. In this paper we use a probabilistic argument, based on Jensen's inequality, to identify the circumstances in which the addition of noise may be beneficial and, equally important, the circumstances in which it may not be beneficial. Using the local convexity of the relationship between airway pressure and tidal volume in the lung, we show that the addition of noise at low volume or low pressure results in higher mean volume (at the same mean pressure) or lower mean pressure (at the same mean volume). The consequence is enhanced gas exchange or less stress on the lungs, both clinically desirable. The argument has implications for other life support devices, such as cardiopulmonary bypass pumps. This paper illustrates the benefits of research that takes place at the interface between mathematics and medicine.
Collapse
Affiliation(s)
- John F Brewster
- Department of Statistics & Institute of Industrial Mathematical Sciences, University of Manitoba, Winnipeg, Manitoba, Canada R3 2N2.
| | | | | |
Collapse
|
47
|
|
48
|
Bellardine CL, Hoffman AM, Tsai L, Ingenito EP, Arold SP, Lutchen KR, Suki B. Comparison of variable and conventional ventilation in a sheep saline lavage lung injury model*. Crit Care Med 2006; 34:439-45. [PMID: 16424726 DOI: 10.1097/01.ccm.0000196208.01682.87] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE There has recently been considerable interest in alternative lung-protective ventilation strategies such as variable ventilation (VV). We aimed at testing VV in a large animal lung injury model and exploring the mechanism of improvement in gas exchange seen with VV. DESIGN Randomized, controlled comparative ventilation study. SETTING Research laboratory at a veterinary hospital. SUBJECTS Female sheep weighing 59.8 +/- 10.57 kg and excised calf lungs. INTERVENTIONS In a sheep saline lavage model of lung injury, we applied VV, whereby tidal volume (VT) and frequency (f) varied on each breath. Sheep were randomized into one of two groups (VV, n = 7; or control, n = 6) and ventilated for 4 hrs with all mean ventilation settings matched. MEASUREMENTS AND MAIN RESULTS Gas exchange, lung mechanics, and hemodynamic measures were recorded over the 4 hrs. VV sheep showed improvement in gas exchange (i.e., oxygenation and carbon dioxide elimination) and ventilation pressures (i.e., reduced mean and peak airway pressures) but control sheep did not. VV sheep also displayed lower-lung elastance and mechanical heterogeneity in comparison with control sheep from 2 to 4 hrs of ventilation. To study the mechanism behind improvements seen with VV, we examined the time course associated with the enhanced recruitment occurring during VV in eight saline-lavaged excised calf lungs. We found that the recruitment associated with a larger VT during VV lasted over 200 secs, nearly an order of magnitude greater than the average time interval between large VT deliveries during VV. CONCLUSIONS The application of VV in a large animal model of lung injury results in improved gas exchange and superior lung mechanics in comparison with CV that can be explained at least partially by the long-lasting effects of the recruitments occurring during VV.
Collapse
|
49
|
Abstract
Alveolar recruitment is one of the primary goals of respiratory care for acute lung injury. It is aimed at improving pulmonary gas exchange and, even more important, at protecting the lungs from ventilator-induced trauma. This review addresses the concept of alveolar recruitment for lung protection in acute lung injury. It provides reasons for why atelectasis and atelectrauma should be avoided; it analyses current and future approaches on how to achieve and preserve alveolar recruitment; and it discusses the possibilities of detecting alveolar recruitment and derecruitment. The latter is of particular clinical relevance because interventions aimed at lung recruitment are often undertaken without simultaneous verification of their effectiveness.
Collapse
Affiliation(s)
- G Mols
- Department of Anaesthesia and Critical Care Medicine, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg, Germany.
| | | | | |
Collapse
|
50
|
Graham MR, Haberman CJ, Brewster JF, Girling LG, McManus BM, Mutch WAC. Mathematical modelling to centre low tidal volumes following acute lung injury: a study with biologically variable ventilation. Respir Res 2005; 6:64. [PMID: 15985159 PMCID: PMC1200564 DOI: 10.1186/1465-9921-6-64] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2005] [Accepted: 06/28/2005] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND With biologically variable ventilation [BVV--using a computer-controller to add breath-to-breath variability to respiratory frequency (f) and tidal volume (VT)] gas exchange and respiratory mechanics were compared using the ARDSNet low VT algorithm (Control) versus an approach using mathematical modelling to individually optimise VT at the point of maximal compliance change on the convex portion of the inspiratory pressure-volume (P-V) curve (Experimental). METHODS Pigs (n = 22) received pentothal/midazolam anaesthesia, oleic acid lung injury, then inspiratory P-V curve fitting to the four-parameter logistic Venegas equation F(P) = a + b[1 + e-(P-c)/d]-1 where: a = volume at lower asymptote, b = the vital capacity or the total change in volume between the lower and upper asymptotes, c = pressure at the inflection point and d = index related to linear compliance. Both groups received BVV with gas exchange and respiratory mechanics measured hourly for 5 hrs. Postmortem bronchoalveolar fluid was analysed for interleukin-8 (IL-8). RESULTS All P-V curves fit the Venegas equation (R2 > 0.995). Control VT averaged 7.4 +/- 0.4 mL/kg as compared to Experimental 9.5 +/- 1.6 mL/kg (range 6.6 - 10.8 mL/kg; p < 0.05). Variable VTs were within the convex portion of the P-V curve. In such circumstances, Jensen's inequality states "if F(P) is a convex function defined on an interval (r, s), and if P is a random variable taking values in (r, s), then the average or expected value (E) of F(P); E(F(P)) > F(E(P))." In both groups the inequality applied, since F(P) defines volume in the Venegas equation and (P) pressure and the range of VTs varied within the convex interval for individual P-V curves. Over 5 hrs, there were no significant differences between groups in minute ventilation, airway pressure, blood gases, haemodynamics, respiratory compliance or IL-8 concentrations. CONCLUSION No difference between groups is a consequence of BVV occurring on the convex interval for individualised Venegas P-V curves in all experiments irrespective of group. Jensen's inequality provides theoretical proof of why a variable ventilatory approach is advantageous under these circumstances. When using BVV, with VT centred by Venegas P-V curve analysis at the point of maximal compliance change, some leeway in low VT settings beyond ARDSNet protocols may be possible in acute lung injury. This study also shows that in this model, the standard ARDSNet algorithm assures ventilation occurs on the convex portion of the P-V curve.
Collapse
Affiliation(s)
- M Ruth Graham
- Department of Anesthesia, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Craig J Haberman
- Department of Anesthesia, University of Manitoba, Winnipeg, Manitoba, Canada
| | - John F Brewster
- Institute of Industrial Mathematical Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Linda G Girling
- Department of Anesthesia, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Bruce M McManus
- Department of Pathology and Laboratory Medicine, James Hogg iCAPTURE Centre for Cardiovascular and Pulmonary Research, University of British Columbia, Vancouver, British Columbia, Canada
| | - W Alan C Mutch
- Department of Anesthesia, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|