1
|
Prem Senthil M, Anand S, Chakraborty R, Bordon JE, Constable PA, Brown S, Al-Dasooqi D, Simon S. Exploring the utility of retinal optical coherence tomography as a biomarker for idiopathic intracranial hypertension: a systematic review. J Neurol 2024; 271:4769-4793. [PMID: 38856724 PMCID: PMC11319609 DOI: 10.1007/s00415-024-12481-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 05/24/2024] [Accepted: 05/26/2024] [Indexed: 06/11/2024]
Abstract
This study aimed to examine the existing literature that investigated the effectiveness of optical coherence tomography (OCT) and optical coherence tomography angiography (OCT-A) as a biomarker for idiopathic intracranial hypertension (IIH). Our search was conducted on January 17th, 2024, and included the databases, Medline, Scopus, Embase, Cochrane, Latin American and Caribbean Health Sciences Literature (LILACS), International Standard Randomized Controlled Trial Number (ISRCTN) registry, and the International Clinical Trials Registry Platform (ICTRP). Our final review included 84 articles. In 74 studies, OCT was utilized as the primary ocular imaging method, while OCT-A was employed in two studies including eight studies that utilized both modalities. Overall, the results indicated that IIH patients exhibited significant increases in retinal nerve fiber layer (RNFL) thickness, total retinal and macular thickness, optic nerve head volume, and height, optic disc diameter and area, rim area, and thickness compared to controls. A significant correlation was observed between cerebrospinal fluid (CSF) pressure and OCT parameters including RNFL thickness, total retinal thickness, macular thickness, optic nerve head volume, and optic nerve head height. Interventions aimed at lowering CSF pressure were associated with a substantial improvement in these parameters. Nevertheless, studies comparing peripapillary vessel density using OCT-A between IIH patients and controls yielded conflicting results. Our systematic review supports OCT as a powerful tool to accurately monitor retinal axonal and optic nerve head changes in patients with IIH. Future research is required to determine the utility of OCT-A in IIH.
Collapse
Affiliation(s)
- Mallika Prem Senthil
- College of Nursing and Health Sciences, Caring Futures Institute, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia.
| | - Saumya Anand
- College of Nursing and Health Sciences, Caring Futures Institute, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia
| | - Ranjay Chakraborty
- College of Nursing and Health Sciences, Caring Futures Institute, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia
| | - Jose Estevez Bordon
- College of Nursing and Health Sciences, Caring Futures Institute, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia
| | - Paul A Constable
- College of Nursing and Health Sciences, Caring Futures Institute, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia
| | - Shannon Brown
- Central Library, Flinders University, Bedford Park, Adelaide, South Australia, Australia
| | - Dalia Al-Dasooqi
- College of Nursing and Health Sciences, Caring Futures Institute, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia
| | - Simu Simon
- University of Adelaide, Adelaide, South Australia, Australia
| |
Collapse
|
2
|
Abri Aghdam K, Soltan Sanjari M, Chaibakhsh S, Fathi Z, Kazemi P, Aghajani A. Assessment of the relationship between structural and functional tests in patients with idiopathic intracranial hypertension. Int Ophthalmol 2024; 44:121. [PMID: 38427085 DOI: 10.1007/s10792-024-03054-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 02/16/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE To assess the relationship between structural and functional tests in mild and moderate idiopathic intracranial hypertension (IIH). METHODS Patients with mild and moderate IIH and a control group were enrolled. Best-corrected visual acuity (BCVA), macular ganglion cell layer (MGCL) thickness, peripapillary retinal nerve fiber layer (pp RNFL) thickness, perimetric mean deviation (MD), and photopic negative responses (PhNR) of the electroretinogram were recorded. The associations between structural (pp RNFL and MGCL thickness) and functional (PhNR amplitude, MD and BCVA) parameters were assessed. RESULTS 154 eyes from 78 subjects (74 eyes from IIH patients and 80 eyes from healthy subjects) were included in this comparative observational study. The MGCL thickness, VA, pp RNFL, and PhNR base-to-trough (BT) amplitude were significantly worse in moderate IIH. The BCVA and MD were associated with MGCL thickness only in moderate IIH. The relationship between MD and MGCL thickness started when MD fell below -5.7 dB. CONCLUSIONS The association between functional and structural parameters varies between mild and moderate IIH. The MD and MGCL thickness outperformed in assessing disease severity in mild and moderate IIH, respectively. The association between MD and MGCL thickness could be considered in IIH severity categorization.
Collapse
Affiliation(s)
- Kaveh Abri Aghdam
- Eye Research Center, Eye Department, The Five Senses Health Institute, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Mostafa Soltan Sanjari
- Eye Research Center, Eye Department, The Five Senses Health Institute, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Samira Chaibakhsh
- Rajaie Cardiovascular Medical and Research Institute, Iran University of Medical Sciences, Tehran, Iran
| | - Zahra Fathi
- Eye Research Center, Eye Department, The Five Senses Health Institute, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Pegah Kazemi
- Eye Research Center, Eye Department, The Five Senses Health Institute, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Aghajani
- Isfahan Eye Research Center, Department of Ophthalmology, Isfahan University of Medical Sciences, Isfahan, Iran.
| |
Collapse
|
3
|
Tsay K, Safari S, Abou-Samra A, Kremers J, Tzekov R. Pre-stimulus bioelectrical activity in light-adapted ERG under blue versus white background. Vis Neurosci 2023; 40:E004. [PMID: 38087845 PMCID: PMC11016353 DOI: 10.1017/s0952523823000032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 11/13/2023] [Accepted: 10/30/2023] [Indexed: 12/18/2023]
Abstract
To compare the baseline signal between two conditions used to generate the photopic negative response (PhNR) of the full-field electroretinogram (ERG): red flash on a blue background (RoB) and white flash on a white background (LA3). The secondary purpose is to identify how the level of pre-stimulus signal affects obtaining an unambiguous PhNR component. A retrospective chart review was conducted on four cohorts of patients undergoing routine ERG testing. In each group, LA3 was recorded the same way while RoB was generated differently using various luminances of red and blue light. The background bioelectrical activity 30 ms before the flash was extracted, and the root mean square (RMS) of the signal was calculated and compared between RoB and LA3 using Wilcoxon test. Pre-stimulus noise was significantly higher under RoB stimulation versus LA3 in all four conditions for both right and left eyes (ratio RoB/LA3 RMS 1.70 and 1.57 respectively, p < 0.033). There was also no significant difference between the RMS of either LA3 or RoB across protocols, indicating that the baseline noise across cohorts were comparable. Additionally, pre-stimulus noise was higher in signals where PhNR was not clearly identifiable as an ERG component versus signals with the presence of unambiguous PhNR component under RoB in all four groups for both eyes (p < 0.05), whereas the difference under LA3 was less pronounced. Our study suggests that LA3 produces less background bioelectrical activity, likely due to decreased facial muscle activity. As it seems that the pre-stimulus signal level affects PhNR recordability, LA3 may also produce a better-quality signal compared to RoB. Therefore, until conditions for a comparable bioelectrical activity under RoB are established, we believe that LA3 should be considered at least as a supplementary method to evaluate retinal ganglion cell function by ERG.
Collapse
Affiliation(s)
- Katherine Tsay
- Morsani College of Medicine, University of South Florida, Tampa, FL, USA
| | - Sara Safari
- Morsani College of Medicine, University of South Florida, Tampa, FL, USA
| | | | - Jan Kremers
- University Hospital Erlangen, Erlangen, Germany
| | - Radouil Tzekov
- Department of Ophthalmology, University of South Florida, Tampa, FL, USA
- Department of Medical Engineering, University of South Florida, Tampa, FL, USA
| |
Collapse
|
4
|
Polat OA, Gultekin M, Sener H, Ozer F, Arda H. Retinal dysfunction in Parkinson's disease-results of the extended protocol for photopic negative response (PHNR) full-field electroretinogram (ERG). Doc Ophthalmol 2023; 147:89-98. [PMID: 37515709 DOI: 10.1007/s10633-023-09945-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 07/06/2023] [Indexed: 07/31/2023]
Abstract
BACKGROUND We investigated whether the photopic negative response (PhNR) in the electroretinogram (ERG) was affected in Parkinson's disease (PD) patients and whether it was associated with retinal changes on optical coherence tomography (OCT). METHODS Thirty-two patients with PD and 31 age and sex-matched healthy controls from a single tertiary centre were included in the study. Hoehn and Yahr scale scores and the presence of REM sleep behaviour were recorded. PhNR, a-wave and b-wave responses in photopic ERG (red on blue background) and retinal layer thicknesses in OCT were obtained. RESULTS The mean age was 61 ± 10.4 in the PD group (female/male: 18/14) and 60.9 ± 7 in the control group (female/male: 18/13). The amplitudes of the PhNR, a- and b-waves in the ERG were significantly decreased in the PD group, but the implicit times were not significantly different. BCVA was significantly correlated with Hoehn and Yahr scores (p < 0.001, r = - 0.596). There was a significant correlation between BCVA and a-wave amplitude (p = 0.047, r = - 0.251). On OCT analysis, the thickness of the nasal INL was increased, and the temporal and inferior OPL and temporal peripapillary RNFL were decreased in the PD group compared to healthy controls (p = 0.032, p = 0.002, p = 0.016 and p = 0.012, respectively). CONCLUSION This study demonstrated reduced a-wave, b-wave and PhNR-wave amplitudes on ERG measurements in PD patients. These findings suggest that the whole ERG response, not just the PhNR, is attenuated in patient with PD, suggesting a possible involvement of the visual system in the disease.
Collapse
Affiliation(s)
- Osman Ahmet Polat
- Department of Ophthalmology, Erciyes University Medical Faculty, Kayseri, Turkey.
| | - Murat Gultekin
- Department of Neurology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Hidayet Sener
- Department of Ophthalmology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Furkan Ozer
- Department of Ophthalmology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Hatice Arda
- Department of Ophthalmology, Erciyes University Medical Faculty, Kayseri, Turkey
| |
Collapse
|
5
|
Miao Q, Cheng Y, Zheng H, Yuan J, Chen C. PhNR and Peripapillary RNFL Changes in Leber Hereditary Optic Neuropathy With m.G11778A Mutation. Mitochondrion 2023; 70:111-117. [PMID: 37127073 DOI: 10.1016/j.mito.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 02/08/2023] [Accepted: 04/23/2023] [Indexed: 05/03/2023]
Abstract
PURPOSE To analyze the functional and structural changes in retinal ganglion cells (RGCs) and their axons that occur during Leber's hereditary optic neuropathy (LHON) using photopic negative response (PhNR) and spectral domain optical coherence tomography (SD-OCT). METHODS Individuals diagnosed with LHON and their family members were invited to participate in this cross-sectional study. PhNR and OCT were used. The PhNR amplitude and peripapillary retinal nerve fiber layer (pRNFL) thicknesses were compared among the three groups. In addition, affected individuals were divided into subacute, dynamic and chronic phases based on disease duration in order to evaluate the decay in RGCs function and structure. RESULTS 73 affected and 30 carriers with a m.11778G>A mutation were included. PhNR amplitude and the thickness of pRNFL significantly decreased in affected individuals and carriers compared to that of the controls (P<0.001). However, there was no difference between the carriers and the controls (P>0.05). There was no difference in the PhNR amplitude of different phases (P=0.464). In the subacute phase, only temporal pRNFL thickness decreased significantly (P<0.001). PRNFL thickness decreased significantly in dynamic phase (P<0.001). Temporal pRNFL thickness continued to decrease in the chronic phase (P=0.042). CONCLUSION In the subacute phase, the function of RGCs was severely impaired. Thickness of pRNFL decreased significantly in four quadrants during disease progression. In the chronic phase, pRNFL thickness decreased slightly. Carriers have shown RGCs dysfunction before pathological changes occur, suggesting subclinical abnormalities.
Collapse
Affiliation(s)
- Qingmei Miao
- Eye Center, Renmin Hospital of Wuhan University, Wuhan 430060, China
| | - Yufang Cheng
- Eye Center, Renmin Hospital of Wuhan University, Wuhan 430060, China
| | - Hongmei Zheng
- Eye Center, Renmin Hospital of Wuhan University, Wuhan 430060, China
| | - Jiajia Yuan
- Eye Center, Renmin Hospital of Wuhan University, Wuhan 430060, China.
| | - Changzheng Chen
- Eye Center, Renmin Hospital of Wuhan University, Wuhan 430060, China.
| |
Collapse
|
6
|
Barbano L, Ziccardi L, Antonelli G, Nicoletti CG, Landi D, Mataluni G, Falsini B, Marfia GA, Centonze D, Parisi V. Multifocal Electroretinogram Photopic Negative Response: A Reliable Paradigm to Detect Localized Retinal Ganglion Cells' Impairment in Retrobulbar Optic Neuritis Due to Multiple Sclerosis as a Model of Retinal Neurodegeneration. Diagnostics (Basel) 2022; 12:diagnostics12051156. [PMID: 35626311 PMCID: PMC9139610 DOI: 10.3390/diagnostics12051156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 04/28/2022] [Accepted: 05/05/2022] [Indexed: 11/28/2022] Open
Abstract
The measure of the full-field photopic negative response (ff-PhNR) of light-adapted full-field electroretinogram (ff-ERG) allows to evaluate the function of the innermost retinal layers (IRL) containing primarily retinal ganglion cells (RGCs) and other non-neuronal elements of the entire retina. The aim of this study was to acquire functional information of localized IRL by measuring the PhNR in response to multifocal stimuli (mfPhNR). In this case-control observational and retrospective study, we assessed mfPhNR responses from 25 healthy controls and from 20 patients with multiple sclerosis with previous history of optic neuritis (MS-ON), with full recovery of visual acuity, IRL morphological impairment, and absence of morpho-functional involvement of outer retinal layers (ORL). MfPhNR response amplitude densities (RADs) were measured from concentric rings (R) with increasing foveal eccentricity: 0−5° (R1), 5−10° (R2), 10−15° (R3), 15−20° (R4), and 20−25° (R5) from retinal sectors (superior-temporal (ST), superior-nasal (SN), inferior-nasal (IN), and inferior-temporal (IT)); between 5° and 20° and from retinal sectors (superior (S), temporal (T), inferior (I), and nasal (N)); and within 5° to 10° and within 10° and 20° from the fovea. The mfPhNR RAD values observed in all rings or sectors in MS-ON eyes were significantly reduced (p < 0.01) with respect to control ones. Our results suggest that mfPhNR recordings may detect localized IRL dysfunction in the pathologic condition of selective RGCs neurodegeneration.
Collapse
Affiliation(s)
- Lucilla Barbano
- IRCCS—Fondazione Bietti, Via Livenza 1, 00198 Rome, Italy; (L.B.); (G.A.); (V.P.)
| | - Lucia Ziccardi
- IRCCS—Fondazione Bietti, Via Livenza 1, 00198 Rome, Italy; (L.B.); (G.A.); (V.P.)
- Correspondence: ; Tel.: +39-06-85356727; Fax: +39-06-84242333
| | - Giulio Antonelli
- IRCCS—Fondazione Bietti, Via Livenza 1, 00198 Rome, Italy; (L.B.); (G.A.); (V.P.)
| | - Carolina Gabri Nicoletti
- Multiple Sclerosis Clinical and Research Unit, Department of Systems Medicine, Tor Vergata University, Via Montpellier 1, 00133 Rome, Italy; (C.G.N.); (D.L.); (G.M.); (G.A.M.); (D.C.)
| | - Doriana Landi
- Multiple Sclerosis Clinical and Research Unit, Department of Systems Medicine, Tor Vergata University, Via Montpellier 1, 00133 Rome, Italy; (C.G.N.); (D.L.); (G.M.); (G.A.M.); (D.C.)
| | - Giorgia Mataluni
- Multiple Sclerosis Clinical and Research Unit, Department of Systems Medicine, Tor Vergata University, Via Montpellier 1, 00133 Rome, Italy; (C.G.N.); (D.L.); (G.M.); (G.A.M.); (D.C.)
| | - Benedetto Falsini
- Ophthalmology Department, IRCCS—Fondazione Policlinico Universitario A. Gemelli, Catholic University, Largo F. Vito 1, 00168 Rome, Italy;
| | - Girolama Alessandra Marfia
- Multiple Sclerosis Clinical and Research Unit, Department of Systems Medicine, Tor Vergata University, Via Montpellier 1, 00133 Rome, Italy; (C.G.N.); (D.L.); (G.M.); (G.A.M.); (D.C.)
| | - Diego Centonze
- Multiple Sclerosis Clinical and Research Unit, Department of Systems Medicine, Tor Vergata University, Via Montpellier 1, 00133 Rome, Italy; (C.G.N.); (D.L.); (G.M.); (G.A.M.); (D.C.)
- Unit of Neurology and Neurorehabilitation, IRCCS—Neuromed, Via Atinense 18, 86077 Pozzilli, Italy
| | - Vincenzo Parisi
- IRCCS—Fondazione Bietti, Via Livenza 1, 00198 Rome, Italy; (L.B.); (G.A.); (V.P.)
| |
Collapse
|
7
|
Chen S, Li M, Sun J, Wang D, Weng C, Zeng Y, Li Y, Huo S, Huang X, Li S, Zou T, Xu H. Human Umbilical Cord Blood-Derived CD133+CD34+ Cells Protect Retinal Endothelial Cells and Ganglion Cells in X-Irradiated Rats through Angioprotective and Neurotrophic Factors. Front Cell Dev Biol 2022; 10:801302. [PMID: 35223834 PMCID: PMC8866877 DOI: 10.3389/fcell.2022.801302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 01/12/2022] [Indexed: 11/13/2022] Open
Abstract
Radiation retinopathy (RR) is a common complication following radiation therapy of globe, head, and neck malignancies, and is characterized by microangiopathy, neuroretinopathy, and the irreversible loss of visual function. To date, there is no effective treatment for RR. Stem cells have been clinically used to treat retinal degeneration. CD133+CD34+ cells from human umbilical cord blood (hUCB-CD133+CD34+ cells), a subpopulation of hematopoietic stem cells, were applied to determine their protective efficacy on irradiated rat retinas. After X-ray irradiation on the retinas, rats were intravitreally injected with hUCB-CD133+CD34+ cells. Transplantation of hUCB-CD133+CD34+ cells prevented retinal dysfunction 2 weeks post-operation and lasted at least 8 weeks. CD133+CD34+ cells were distributed along the retinal vessel and migrated to the ganglion cell layer. Moreover, grafted CD133+CD34+ cells reduced the apoptosis of endothelial and ganglion cells in irradiated rats and increased the number of survived CD31+ retinal endothelial cells and Brn3a+ ganglion cells at 2 and 4 weeks, respectively, post-operation. Co-culturing of CD133+CD34+ cells or supernatants with irradiated human retinal microvascular endothelial cells (hRECs) in vitro, confirmed that CD133+CD34+ cells ameliorated hREC apoptosis caused by irradiation. Mechanistically, we found that angioprotective mediators and neurotrophic factors were secreted by CD133+CD34+ cells, which might attenuate irradiation-induced injury of retinal endothelial cells and ganglion cells. hUCB-CD133+CD34+ cell transplantation, as a novel treatment, protects retinal endothelial and ganglion cells of X-irradiated rat retinas, possibly through angioprotective and neurotrophic factors.
Collapse
Affiliation(s)
- Siyu Chen
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Minghui Li
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Jianguo Sun
- Cancer Institute, Xinqiao Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Dan Wang
- Department of Obstetrics and Gynecology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Chuanhuang Weng
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Yuxiao Zeng
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Yijian Li
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Shujia Huo
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Xiaona Huang
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Shiying Li
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
| | - Ting Zou
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
- *Correspondence: Ting Zou, ; Haiwei Xu,
| | - Haiwei Xu
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing, China
- Key Lab of Visual Damage and Regeneration and Restoration of Chongqing, Chongqing, China
- *Correspondence: Ting Zou, ; Haiwei Xu,
| |
Collapse
|
8
|
Diao T, Kushzad F, Patel MD, Bindiganavale MP, Wasi M, Kochenderfer MJ, Moss HE. Comparison of Machine Learning Approaches to Improve Diagnosis of Optic Neuropathy Using Photopic Negative Response Measured Using a Handheld Device. Front Med (Lausanne) 2021; 8:771713. [PMID: 34926514 PMCID: PMC8677942 DOI: 10.3389/fmed.2021.771713] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 11/05/2021] [Indexed: 11/20/2022] Open
Abstract
The photopic negative response of the full-field electroretinogram (ERG) is reduced in optic neuropathies. However, technical requirements for measurement and poor classification performance have limited widespread clinical application. Recent advances in hardware facilitate efficient clinic-based recording of the full-field ERG. Time series classification, a machine learning approach, may improve classification by using the entire ERG waveform as the input. In this study, full-field ERGs were recorded in 217 eyes (109 optic neuropathy and 108 controls) of 155 subjects. User-defined ERG features including photopic negative response were reduced in optic neuropathy eyes (p < 0.0005, generalized estimating equation models accounting for age). However, classification of optic neuropathy based on user-defined features was only fair with receiver operating characteristic area under the curve ranging between 0.62 and 0.68 and F1 score at the optimal cutoff ranging between 0.30 and 0.33. In comparison, machine learning classifiers using a variety of time series analysis approaches had F1 scores of 0.58–0.76 on a test data set. Time series classifications are promising for improving optic neuropathy diagnosis using ERG waveforms. Larger sample sizes will be important to refine the models.
Collapse
Affiliation(s)
- Tina Diao
- Department of Management Science & Engineering, Stanford University, Stanford, CA, United States
| | - Fareshta Kushzad
- Department of Ophthalmology, Stanford University, Palo Alto, CA, United States
| | - Megh D Patel
- Department of Ophthalmology, Stanford University, Palo Alto, CA, United States
| | | | - Munam Wasi
- Department of Ophthalmology, Stanford University, Palo Alto, CA, United States
| | - Mykel J Kochenderfer
- Department of Ophthalmology, Stanford University, Palo Alto, CA, United States.,Department of Aeronautics and Astronautics, Stanford University, Stanford, CA, United States
| | - Heather E Moss
- Department of Ophthalmology, Stanford University, Palo Alto, CA, United States.,Department of Neurology and Neurological Sciences, Stanford University, Palo Alto, CA, United States
| |
Collapse
|
9
|
Marmoy OR, Viswanathan S. Clinical electrophysiology of the optic nerve and retinal ganglion cells. Eye (Lond) 2021; 35:2386-2405. [PMID: 34117382 PMCID: PMC8377055 DOI: 10.1038/s41433-021-01614-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/11/2021] [Accepted: 05/19/2021] [Indexed: 12/28/2022] Open
Abstract
Clinical electrophysiological assessment of optic nerve and retinal ganglion cell function can be performed using the Pattern Electroretinogram (PERG), Visual Evoked Potential (VEP) and the Photopic Negative Response (PhNR) amongst other more specialised techniques. In this review, we describe these electrophysiological techniques and their application in diseases affecting the optic nerve and retinal ganglion cells with the exception of glaucoma. The disease groups discussed include hereditary, compressive, toxic/nutritional, traumatic, vascular, inflammatory and intracranial causes for optic nerve or retinal ganglion cell dysfunction. The benefits of objective, electrophysiological measurement of the retinal ganglion cells and optic nerve are discussed, as are their applications in clinical diagnosis of disease, determining prognosis, monitoring progression and response to novel therapies.
Collapse
Affiliation(s)
- Oliver R Marmoy
- Clinical and Academic Department of Ophthalmology, Great Ormond Street Hospital for Children, London, UK.
- UCL-GOS Institute for Child Health, University College London, London, UK.
- Manchester Metropolitan University, Manchester, UK.
| | | |
Collapse
|
10
|
Marmoy OR, Hodson-Tole E, Thompson DA. Photopic negative response (PhNR) in the diagnosis and monitoring of raised intracranial pressure in children: a prospective cross-sectional and longitudinal protocol. BMJ Open 2021; 11:e047299. [PMID: 34285008 PMCID: PMC8292810 DOI: 10.1136/bmjopen-2020-047299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Raised intracranial pressure (rICP) can be a consequence of a variety of neurological disorders. A significant complication of rICP is visual impairment, due to retinal ganglion cell (RGC) dysfunction. In children, subjective measurements to monitor this, such as visual field examination, are challenging. Therefore, objective measurements offer promising alternatives for monitoring these effects. The photopic negative response (PhNR) is a component of the flash electroretinogram produced by RGCs; the cells directly affected in rICP-related vision loss. This project aims to assess the clinical feasibility and diagnostic efficacy of the PhNR in detecting and monitoring paediatric rICP. METHODS AND ANALYSIS Section 1 is a cross-sectional study; group 1 young persons with disorders associated with rICP and a comparator group 2 of age-matched children without rICP. Both groups will undergo a PhNR recording alongside a series of structural and functional ophthalmic investigations, with the rICP group also having measurement of intracranial pressure.Section 2 is a longitudinal study of the relationship between the PhNR and directly recorded intracranial pressure measurements, through repeated measures. PhNR amplitudes and peak times will be assessed against optical coherence tomography parameters, mean deviation of visual fields, other electrophysiology and ICP measurement through regression analyses.Group differences between PhNR measurements in the rICP and control groups will be performed to determine clinically relevant cut-off values and calculation of diagnostic accuracy. Longitudinal analysis will assess PhNR amplitude against ICP measurements through regression analysis. Feasibility and efficacy will be measured through acceptability, practicality and sensitivity outcomes. ETHICS AND DISSEMINATION Favourable opinion from a research ethics committee has been received and the study approved by Manchester Metropolitan University, the Health Research Authority and the Great Ormond Street Institute of Child Health (GOS-ICH) Research and Development office. This project is being undertaken as a doctoral award (ORM) with findings written for academic thesis submission, peer-reviewed journal and conference publications.
Collapse
Affiliation(s)
- Oliver Rajesh Marmoy
- Clinical and Academic Department of Ophthalmology, Great Ormond Street Hospital For Children NHS Foundation Trust, London, UK
- School of Healthcare Science, Manchester Metropolitan University, Manchester, UK
- GOS-ICH, University College London, London, UK
| | - Emma Hodson-Tole
- Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, UK
| | - Dorothy Ann Thompson
- Clinical and Academic Department of Ophthalmology, Great Ormond Street Hospital For Children NHS Foundation Trust, London, UK
- GOS-ICH, University College London, London, UK
| |
Collapse
|
11
|
Raharja A, Leo SM, Chow I, Indusegaran M, Hammond CJ, Mahroo OA, Wong SH. Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device. Life (Basel) 2021; 11:437. [PMID: 34068365 PMCID: PMC8153331 DOI: 10.3390/life11050437] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/07/2021] [Accepted: 05/11/2021] [Indexed: 11/16/2022] Open
Abstract
The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal electroretinography. This study explored the use of a handheld device (RETeval, LKC technologies, Gaithersburg, MD, USA) in 72 IIH patients of varying stages and severity (and seven controls) and investigated associations between PhNR parameters and disease severity. PhNR amplitudes at 72 ms (P72) and p-ratio (ratio to b-wave peak value) differed significantly across groups, with a trend towards smaller amplitudes in those with severe IIH, defined as papilloedema with Modified Frisén Scale (MFS) ≥ 3, retinal nerve fibre layer (RNFL) ≥ 150 μm or atrophic papilloedema (p = 0.0048 and p = 0.018 for P72 and p-ratio, respectively). PhNR parameters did not correlate with MFS, RNFL thickness, standard automated perimetry mean deviation or macular ganglion cell layer volume. This study suggests that PhNR measurement using a handheld device is feasible and could potentially augment the assessment of disease severity in IIH. The clinical utility of PhNR monitoring in IIH patients requires further investigation.
Collapse
Affiliation(s)
- Antony Raharja
- Medical Eye Unit, St Thomas’ Hospital, London SE1 7EH, UK;
- Department of Ophthalmology, Guys & St Thomas’ NHS Foundation Trust, London SE1 7EH, UK; (I.C.); (M.I.); (C.J.H.); (O.A.M.)
| | - Shaun M. Leo
- Institute of Ophthalmology, University College London, London EC1V 9EL, UK;
- Moorfields Eye Hospital NHS Foundation Trust, London EC1V 2PD, UK
| | - Isabelle Chow
- Department of Ophthalmology, Guys & St Thomas’ NHS Foundation Trust, London SE1 7EH, UK; (I.C.); (M.I.); (C.J.H.); (O.A.M.)
- Section of Ophthalmology, King’s College London, London SE1 7EH, UK
| | - Mathura Indusegaran
- Department of Ophthalmology, Guys & St Thomas’ NHS Foundation Trust, London SE1 7EH, UK; (I.C.); (M.I.); (C.J.H.); (O.A.M.)
- Section of Ophthalmology, King’s College London, London SE1 7EH, UK
| | - Christopher J. Hammond
- Department of Ophthalmology, Guys & St Thomas’ NHS Foundation Trust, London SE1 7EH, UK; (I.C.); (M.I.); (C.J.H.); (O.A.M.)
- Section of Ophthalmology, King’s College London, London SE1 7EH, UK
| | - Omar A. Mahroo
- Department of Ophthalmology, Guys & St Thomas’ NHS Foundation Trust, London SE1 7EH, UK; (I.C.); (M.I.); (C.J.H.); (O.A.M.)
- Institute of Ophthalmology, University College London, London EC1V 9EL, UK;
- Moorfields Eye Hospital NHS Foundation Trust, London EC1V 2PD, UK
- Section of Ophthalmology, King’s College London, London SE1 7EH, UK
| | - Sui H. Wong
- Medical Eye Unit, St Thomas’ Hospital, London SE1 7EH, UK;
- Department of Ophthalmology, Guys & St Thomas’ NHS Foundation Trust, London SE1 7EH, UK; (I.C.); (M.I.); (C.J.H.); (O.A.M.)
- Moorfields Eye Hospital NHS Foundation Trust, London EC1V 2PD, UK
| |
Collapse
|
12
|
Mitchell C, Mathew S, Harris A, Lang M, Mackay D, Kovoor J. Etiology, pathogenesis and management of idiopathic intracranial hypertension, and role of optic canal size in asymmetric papilledema: A review. Eur J Ophthalmol 2021; 31:892-903. [PMID: 33779328 DOI: 10.1177/11206721211005709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Idiopathic intracranial hypertension (IIH) is characterized by raised intracranial pressure of unknown origin that primarily afflicts obese women of childbearing age. There are several treatment options, but currently there are none that are effective for the entire affected population. The lack of a universally effective treatment is related to an incomplete understanding of the etiology of the condition and the lack of a well-defined pathophysiological mechanism for the disease process. Classically, IIH has been thought of as a diagnosis of exclusion once radiographical imaging has ruled out all other causes of elevated intracranial pressure. Today, we know that imaging does capture subtle changes, and might provide keys to finally understand the pathogenesis of IIH so that a definitive treatment can be discovered or developed. Recently, advancements in radiography, optical coherence tomography, and electroretinography have shown promise for the future of IIH evaluation. A topic within IIH imaging that has recently sparked interest is the possibility that the severity of papilledema may have an association with the size of the optic canal. In this article, we also discuss the recent studies on the relationship between asymmetric papilledema and optic canal size.
Collapse
Affiliation(s)
- Chandler Mitchell
- Eugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Sunu Mathew
- Eugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Alon Harris
- Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Matthew Lang
- Eugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Devin Mackay
- Eugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, Indianapolis, IN, USA.,Department of Neurology, Indiana University School of Medicine, Indianapolis, IN, USA.,Department of Neurosurgery, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Jerry Kovoor
- Department of Radiology, Indiana University School of Medicine, Indianapolis, IN, USA
| |
Collapse
|
13
|
Asanad S, Felix CM, Fantini M, Harrington MG, Sadun AA, Karanjia R. Retinal ganglion cell dysfunction in preclinical Alzheimer's disease: an electrophysiologic biomarker signature. Sci Rep 2021; 11:6344. [PMID: 33737516 PMCID: PMC7973731 DOI: 10.1038/s41598-021-85010-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 02/20/2021] [Indexed: 11/09/2022] Open
Abstract
The current study evaluated retinal function using electroretinography (ERG) in cognitively healthy (CH) participants with preclinical Alzheimer's disease (AD), as classified by cerebral spinal fluid (CSF) Aβ42/Tau ratio. Individuals with normal retinal morphology ascertained by spectral-domain optical coherence tomography were enrolled. Full-field ERG, pattern PERG, and photopic negative response (PhNR) were performed in 29 adult participants (58 eyes). Amplitude and implicit times of the ERG wave components were analyzed. Preclinical AD participants showed marked retinal ganglion cell dysfunction relative to controls. The PhNR was significantly diminished in preclinical AD relative to controls. PhNR amplitude and N95 implicit time differentiated CH individuals with CSF biomarkers of AD pathology with 87% sensitivity and 82% specificity. These quantitative electrophysiologic findings expand our understanding of early retinal functional changes that precede cognitive decline in AD. Retinal ganglion cell dysfunction, as detected by ERG, may be a clinically useful, non-invasive in vivo biomarker for early disease detection, which is necessary for ultimately pursuing early intervention.
Collapse
Affiliation(s)
- Samuel Asanad
- Doheny Eye Centers-UCLA, Pasadena, CA, USA. .,Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD, USA.
| | - Christian M Felix
- Charles R. Drew University of Medicine and Science, Los Angeles, CA, USA.,David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA
| | - Michele Fantini
- Department of Ophthalmology, Sacro Cuore Don Calabria Hospital, Negrar, Italy
| | | | - Alfredo A Sadun
- Doheny Eye Centers-UCLA, Pasadena, CA, USA.,David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA
| | - Rustum Karanjia
- Doheny Eye Centers-UCLA, Pasadena, CA, USA.,David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA.,Department of Ophthalmology, University of Ottawa, Ottawa, ON, Canada.,Ottawa Hospital Research Institute, Ottawa, ON, Canada
| |
Collapse
|
14
|
Botelho GIS, Salomão SR, Tengan CH, Karanjia R, Moura FV, Rocha DM, da Silva PBE, Fernandes AG, Watanabe SES, Sacai PY, Belfort R, Carelli V, Sadun AA, Berezovsky A. Impaired Ganglion Cell Function Objectively Assessed by the Photopic Negative Response in Affected and Asymptomatic Members From Brazilian Families With Leber's Hereditary Optic Neuropathy. Front Neurol 2021; 11:628014. [PMID: 33584522 PMCID: PMC7874135 DOI: 10.3389/fneur.2020.628014] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 12/21/2020] [Indexed: 01/13/2023] Open
Abstract
Purpose: The photopic negative response (PhNR) is an electrophysiological method that provides retinal ganglion cell function assessment using full-field stimulation that does not require clear optics or refractive correction. The purpose of this study was to assess ganglion cell function by PhNR in affected and asymptomatic carriers from Brazilian families with LHON. Methods: Individuals either under suspicion or previously diagnosed with LHON and their family members were invited to participate in this cross-sectional study. Screening for the most frequent LHON mtDNA mutations was performed. Visual acuity, color discrimination, visual fields, pattern-reversal visual evoked potentials (PRVEP), full-field electroretinography and PhNR were tested. A control group of healthy subjects was included. Full-field ERG PhNR were recorded using red (640 nm) flashes at 1 cd.s/m2, on blue (470 nm) rod saturating background. PhNR amplitude (μV) was measured using baseline-to-trough (BT). Optical coherence tomography scans of both the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were measured. PhNR amplitudes among affected, carriers and controls were compared by Kruskal-Wallis test followed by post-hoc Dunn test. The associations between PhNR amplitude and OCT parameters were analyzed by Spearman rank correlation. Results: Participants were 24 LHON affected patients (23 males, mean age=30.5 ± 11.4 yrs) from 19 families with the following genotype: m.11778G>A [N = 15 (62%), 14 males]; m.14484T>C [N = 5 (21%), all males] and m.3460G>A [N = 4 (17%), all males] and 14 carriers [13 females, mean age: 43.2 ± 13.3 yrs; m.11778G>A (N = 11); m.3460G>A (N = 2) and m.14484T>C (N = 1)]. Controls were eight females and seven males (mean age: 32.6 ± 11.5 yrs). PhNR amplitudes were significantly reduced (p = 0.0001) in LHON affected (-5.96 ± 3.37 μV) compared to carriers (-16.53 ± 3.40 μV) and controls (-23.91 ± 4.83; p < 0.0001) and in carriers compared to controls (p = 0.01). A significant negative correlation was found between PhNR amplitude and total macular ganglion cell thickness (r = -0.62, p < 0.05). Severe abnormalities in color discrimination, visual fields and PRVEPs were found in affected and subclinical abnormalities in carriers. Conclusions: In this cohort of Brazilian families with LHON the photopic negative response was severely reduced in affected patients and mildly reduced in asymptomatic carriers suggesting possible subclinical abnormalities in the latter. These findings were similar among pathogenic mutations.
Collapse
Affiliation(s)
- Gabriel Izan Santos Botelho
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Solange Rios Salomão
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Célia Harumi Tengan
- Departamento de Neurologia e Neurocirurgia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Rustum Karanjia
- Doheny Eye Institute, University of California Los Angeles, Los Angeles, CA, United States.,Department of Ophthalmology, Doheny Eye Center, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States.,Ottawa Eye Institute, University of Ottawa, Ottawa, ON, Canada.,Ottawa Hospital Research Institute, Ottawa, ON, Canada
| | - Felipo Victor Moura
- Departamento de Neurologia e Neurocirurgia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Daniel Martins Rocha
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Paula Baptista Eliseo da Silva
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Arthur Gustavo Fernandes
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Sung Eun Song Watanabe
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Paula Yuri Sacai
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Rubens Belfort
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil.,Instituto da Visão-IPEPO, São Paulo, Brazil
| | - Valerio Carelli
- Department of Biomedical and NeuroMotor Sciences (DIBINEM), University of Bologna School of Medicine, Bologna, Italy
| | - Alfredo Arrigo Sadun
- Doheny Eye Institute, University of California Los Angeles, Los Angeles, CA, United States.,Department of Ophthalmology, Doheny Eye Center, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Adriana Berezovsky
- Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| |
Collapse
|
15
|
Mehr JA, Moss HE, Hatami-Marbini H. Numerical Investigation on the Role of Mechanical Factors Contributing to Globe Flattening in States of Elevated Intracranial Pressure. Life (Basel) 2020; 10:life10120316. [PMID: 33260780 PMCID: PMC7760332 DOI: 10.3390/life10120316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/11/2020] [Accepted: 11/23/2020] [Indexed: 11/16/2022] Open
Abstract
Flattening of the posterior eye globe in the magnetic resonance (MR) images is a sign associated with elevated intracranial pressure (ICP), often seen in people with idiopathic intracranial hypertension (IIH). The exact underlying mechanisms of globe flattening (GF) are not fully known but mechanical factors are believed to play a role. In the present study, we investigated the effects of material properties and pressure loads on GF. For this purpose, we used a generic finite element model to investigate the deformation of the posterior eyeball. The degree of GF in numerical models and the significance of different mechanical factors on GF were characterized using an automated angle-slope technique and a statistical measure. From the numerical models, we found that ICP had the most important role in GF. We also showed that the angle-slope graphs pertaining to MR images from five people with high ICP can be represented numerically by manipulating the parameters of the finite element model. This numerical study suggests that GF observed in IIH patients can be accounted for by the forces caused by elevation of ICP from its normal level, while material properties of ocular tissues, such as sclera (SC), peripapillary sclera (PSC), and optic nerve (ON), would impact its severity.
Collapse
Affiliation(s)
- Jafar A. Mehr
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL 60612, USA;
| | - Heather E. Moss
- Departments of Ophthalmology and Neurology & Neurosciences, Stanford University, Palo Alto, CA 94303, USA;
| | - Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL 60612, USA;
- Correspondence:
| |
Collapse
|
16
|
Prencipe M, Perossini T, Brancoli G, Perossini M. The photopic negative response (PhNR): measurement approaches and utility in glaucoma. Int Ophthalmol 2020; 40:3565-3576. [PMID: 32737731 PMCID: PMC7669808 DOI: 10.1007/s10792-020-01515-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 07/17/2020] [Indexed: 11/22/2022]
Abstract
Purpose Visual electrophysiological testing continues to generate interest among glaucoma experts because of its potential help in clarifying disease pathophysiology and promoting early detection of glaucomatous damage. The photopic negative response (PhNR) is a slow negative component of the full-field electroretinogram that has been shown to provide specific information about retinal ganglion cells (RGCs) activity. The purpose of this article is to review the literature to explore the currently available measurement methods and the utility of PhNR in glaucoma diagnostic process. Methods We gathered publications related to the origins, types of stimuli used, measurements methods and applications of the PhNR of ERG in animal models and humans through a search of the literature cited in PubMed. Search terms were: “PhNR”, “photopic negative response”, “glaucoma”, “glaucomatous optic neuropathy”, “ERG”, “electroretinogram”. Results The most reliable PhNR measurements are obtained using a red stimulus on a blue background, without requiring refractive correction, fixation monitoring, or ocular media transparency. Given its direct correlation with RGCs response, the PhNR measured as baseline-to-trough (BT) represents the most reliable parameter of evaluation. Glaucoma patients with evident perimetric defects show pathologic PhNR values. Even though the PhNR is promising in detecting early RGCs impairment, distinguishing between healthy subjects and suspect patients at risk of developing glaucomatous damage still remains challenging. Conclusion The PhNR is a useful additional tool to explore disorders that affect the innermost retina, including glaucoma and other forms of optic neuropathy. In particular, comparing reports of the standard examinations (optic disc assessment, OCT RNFL measurement, standard automated perimetry) with the results of electrophysiological tests may be helpful in solving clinical diagnostic and management dilemmas. On the one hand, the PhNR of the ERG can examine the parvocellular pathways; on the other hand, the steady-state pattern ERG optimized for glaucoma screening (PERGLA) can explore the magnocellular pathways. This could give ophthalmologists a useful feedback to identify early RGCs alterations suggestive of glaucoma, stratify the risk and potentially monitor disease progression.
Collapse
Affiliation(s)
- Matteo Prencipe
- Department of Surgical, Medical, Molecular Pathology and of Critical Area, University of Pisa, Pisa, Italy.
| | - Tommaso Perossini
- Studio Oculistico Associato Mario and Tommaso Perossini, Livorno, Italy
| | | | - Mario Perossini
- Studio Oculistico Associato Mario and Tommaso Perossini, Livorno, Italy
| |
Collapse
|
17
|
Morny EKA, Patel K, Votruba M, Binns AM, Margrain TH. The Relationship Between the Photopic Negative Response and Retinal Ganglion Cell Topography. Invest Ophthalmol Vis Sci 2019; 60:1879-1887. [PMID: 31042794 DOI: 10.1167/iovs.18-25272] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To assess the topographic relationship between the photopic negative response (PhNR) and retinal ganglion cell distribution in healthy individuals. Method Data was recorded from 16 healthy participants. The amplitude of PhNRs obtained in response to focal long duration (250 ms) and brief flash (5 ms), red (660 nm) on blue (469 nm) stimuli of increasing size (5° - full field) were measured. The number of retinal ganglion cell receptive fields (RGCf) in each stimulus area was established from the literature and regression analysis used to determine the relationships between: PhNR amplitude and number of RGCfs stimulated, PhNR density and the RGCf density and response per RGCf as a function of eccentricity. Results The overall amplitude of the PhNR increased with stimulus size and the response density declined from ∼0.1 μV/deg in the macular region to ∼0.003 μV/deg approximately 45° from the fovea. Contrary to expectations, the relationship between the PhNR and number of RGCf was nonlinear, the response from more eccentric neurons being about three times greater than those in the macular region. Conclusions Although the amplitude of the PhNR broadly maps on to the topographic distribution of RGCf the increase in PhNR amplitude with increasing eccentricity is only partly explained by RGCf numbers. Increases in the PhNR amplitude may be due to topographic variations in the contributions from other non-RGC neurons, as well as eccentricity-related morphologic and physiologic differences in RGCs.
Collapse
Affiliation(s)
- Enyam Komla A Morny
- Department of Optometry and Vision Science, University of Cape Coast, Cape Coast, Ghana
| | - Kishan Patel
- School of Optometry and Vision Sciences, Cardiff University, Cardiff, Wales, United Kingdom
| | - Marcela Votruba
- School of Optometry and Vision Sciences, Cardiff University, Cardiff, Wales, United Kingdom.,Eye Unit, University Hospital of Wales, Cardiff, Wales, United Kingdom
| | - Alison M Binns
- School of Health Sciences, City, University of London, London, United Kingdom
| | - Tom H Margrain
- School of Optometry and Vision Sciences, Cardiff University, Cardiff, Wales, United Kingdom
| |
Collapse
|
18
|
The photopic negative response of the Light-adapted 3.0 ERG in clinical settings. Doc Ophthalmol 2019; 140:115-128. [DOI: 10.1007/s10633-019-09723-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 09/16/2019] [Indexed: 11/27/2022]
|
19
|
Park JC, Chau FY, Lim JI, McAnany JJ. Electrophysiological and pupillometric measures of inner retina function in nonproliferative diabetic retinopathy. Doc Ophthalmol 2019; 139:99-111. [PMID: 31016437 DOI: 10.1007/s10633-019-09699-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 04/15/2019] [Indexed: 12/11/2022]
Abstract
PURPOSE To evaluate three measures of inner retina function, the pattern electroretinogram (pERG), the photopic negative response (PhNR), and the post-illumination pupil response (PIPR) in diabetics with and without nonproliferative diabetic retinopathy (NPDR). METHODS Fifteen non-diabetic control subjects and 45 type 2 diabetic subjects participated (15 have no clinically apparent retinopathy [NDR], 15 have mild NPDR, and 15 have moderate/severe NPDR). The pERG was elicited by a contrast-reversing checkerboard pattern, and the PhNR was measured in response to a full-field, long-wavelength flash presented against a short-wavelength adapting field. The PIPR was elicited by a full-field, 450 cd/m2, short-wavelength flash. All responses were recorded and analyzed using conventional techniques. One-way ANOVAs were performed to compare the pERG, PhNR, and PIPR among the control and diabetic groups. RESULTS ANOVA indicated statistically significant differences among the control and diabetic subjects for all three measures. Holm-Sidak post hoc comparisons indicated small, nonsignificant reductions in the pERG (8%), PhNR (8%), and PIPR (10%) for the NDR group compared to the controls (all p > 0.25). In contrast, there were significant reductions in the pERG (35), PhNR (34%), and PIPR (30%) for the mild NPDR group compared to the controls (all p < 0.01). Likewise, there were significant reductions in the pERG (40%), PhNR (32%), and PIPR (32%) for the moderate/severe NPDR group compared to the controls (all p < 0.01). CONCLUSION Abnormalities of the pERG, PhNR, and PIPR suggest inner retina neural dysfunction in diabetics who have clinically apparent vascular abnormalities. Taken together, these measures provide a noninvasive, objective approach to study neural dysfunction in these individuals.
Collapse
Affiliation(s)
- Jason C Park
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., MC/648, Chicago, IL, 60612, USA
| | - Felix Y Chau
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., MC/648, Chicago, IL, 60612, USA
| | - Jennifer I Lim
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., MC/648, Chicago, IL, 60612, USA
| | - J Jason McAnany
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., MC/648, Chicago, IL, 60612, USA. .,Department of Bioengineering, University of Illinois at Chicago, 851 South Morgan St., Chicago, IL, 60607, USA.
| |
Collapse
|
20
|
Tang J, Hui F, Hadoux X, Sarossy M, van Wijngaarden P, Coote M, Crowston JG. A Comparison of the RETeval Sensor Strip and DTL Electrode for Recording the Photopic Negative Response. Transl Vis Sci Technol 2018; 7:27. [PMID: 30619647 PMCID: PMC6314057 DOI: 10.1167/tvst.7.6.27] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Accepted: 10/12/2018] [Indexed: 12/02/2022] Open
Abstract
PURPOSE To compare the RETeval sensor strip and Dawson-Trick-Litzkow (DTL) electrodes for recording the photopic negative response (PhNR) using a portable electroretinogram (ERG) device in eyes with and without glaucoma. METHODS Twenty-six control and 31 glaucoma or glaucoma-suspect participants were recruited. Photopic ERGs were recorded with sensor strip and DTL electrodes in random order using the LKC RETeval device. Stimuli consisted of brief, red flashes (1.7 cd.s/m2) on a blue background (photopic 10 cd/m2). The PhNR amplitude was measured from baseline to trough and also expressed as a ratio over the b-wave amplitude. RESULTS The sensor strip-recorded PhNR amplitude was significantly attenuated (mean ± standard deviation [SD], 4.8 ± 2.1 vs. 12.7 ± 4.8 μV, P < 0.0001), with lower signal-to-noise ratio (SNR; 5.5 ± 2.1 vs. 8.1 ± 3.9, P < 0.0001), and a trend toward a larger PhNR/b-wave ratio compared with DTL electrodes. The PhNR amplitude, implicit time and PhNR/b-wave ratio correlated with visual field mean light sensitivity, although this fell short of significance for the sensor strip recorded PhNR amplitude. The electrodes demonstrated similar intersession repeatability with a coefficient of repeatability of ±27% and ±28% for the DTL and sensor strip, respectively. CONCLUSIONS Sensor strip electrodes are a viable alternative for recording reproducible PhNRs, especially when values are normalized to the b-wave. However, DTL electrodes should be considered in cases of attenuated PhNR, or in elevated noise levels, due to its better signal-to-noise quality. TRANSLATIONAL RELEVANCE Sensor strip electrodes can simplify PhNR recordings in the clinic, potentially eliminating the need for an experienced operator.
Collapse
Affiliation(s)
- Jessica Tang
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Flora Hui
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Xavier Hadoux
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Marc Sarossy
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Peter van Wijngaarden
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Michael Coote
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Jonathan G Crowston
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
21
|
Tang J, Hui F, Coote M, Crowston JG, Hadoux X. Baseline Detrending for the Photopic Negative Response. Transl Vis Sci Technol 2018; 7:9. [PMID: 30258702 PMCID: PMC6152608 DOI: 10.1167/tvst.7.5.9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 08/05/2018] [Indexed: 11/24/2022] Open
Abstract
Purpose The photopic negative response (PhNR) of the light-adapted electroretinogram (ERG) holds promise as an objective marker of retinal ganglion cell function. We compared baseline detrending methods to improve PhNR repeatability without compromising its diagnostic ability in glaucoma. Methods Photopic ERGs were recorded in 20 glaucoma and 18 age-matched control participants. A total of 50 brief, red-flashes (1.6 cd.s/m2) on a blue background (10 photopic cd/m2) were delivered using the RETeval device. Detrending methods compared were: (1) increasing the high-pass filter from 1 to 10 Hz and (2) estimating and removing the trend with an increasing polynomial (order from 1–10) applied to the prestimulus interval, prestimulus and postsignal interval, or the whole ERG signal. Coefficient of repeatability (COR%), unpaired Student's t-test, and area under the receiver operating characteristic curve (AUC) were used to compare the detrending methods. Results Most detrending methods improved PhNR test–retest repeatability compared to the International Society for Clinical Electrophysiology of Vision (ISCEV) recommended 0.3 to 300 Hz band-pass filter (COR% ± 200%). In particular, detrending with a polynomial (order 3) applied to the whole signal performed the best (COR% ± 44%) while achieving similar diagnostic ability as ISCEV band-pass (AUC 0.74 vs. 0.75, respectively). However, over-correcting with higher orders of processing can cause waveform distortion and reduce diagnostic ability. Conclusions Baseline detrending can improve the PhNR repeatability without compromising its clinical use in glaucoma. Further studies exploring more complex processing methods are encouraged. Translational Relevance Baseline detrending can significantly improve the quality of the PhNR.
Collapse
Affiliation(s)
- Jessica Tang
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Flora Hui
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Michael Coote
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Jonathan G Crowston
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Xavier Hadoux
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| |
Collapse
|
22
|
Frishman L, Sustar M, Kremers J, McAnany JJ, Sarossy M, Tzekov R, Viswanathan S. ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram. Doc Ophthalmol 2018; 136:207-211. [PMID: 29855761 PMCID: PMC6061118 DOI: 10.1007/s10633-018-9638-x] [Citation(s) in RCA: 107] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 05/09/2018] [Indexed: 11/24/2022]
Abstract
The International Society for Clinical Electrophysiology of Vision (ISCEV) Standard for full-field electroretinography (ERG) describes a minimum procedure, but encourages more extensive testing. This ISCEV extended protocol describes an extension to the ERG Standard, namely the photopic negative response (PhNR) of the light-adapted flash ERG, as a well-established technique that is broadly accepted by experts in the field. The PhNR is a slow negative-going wave after the b-wave that provides information about the function of retinal ganglion cells and their axons. The PhNR can be reduced in disorders that affect the innermost retina, including glaucoma and other forms of optic neuropathy. This document, based on existing literature, provides a protocol for recording and analyzing the PhNR in response to a brief flash. The protocol includes full-field stimulation, a frequency bandwidth of the recording in which the lower limit does not exceed 0.3 Hz, and a spectrally narrowband stimulus, specifically, a red flash on a rod saturating blue background. Suggested flash strengths cover a range up to and including the minimum required to elicit a maximum amplitude PhNR. This extended protocol for recording the PhNR provides a simple test of generalized retinal ganglion cell function that could be added to standard ERG testing.
Collapse
Affiliation(s)
- Laura Frishman
- College of Optometry, University of Houston, Houston, TX, USA.
| | - Maja Sustar
- Eye Hospital, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Jan Kremers
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - J Jason McAnany
- Department of Ophthalmology and Visual Sciences, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, USA
| | - Marc Sarossy
- Department of Ophthalmology, Centre for Eye Research Australia, The Royal Victorian Eye and Ear Hospital, University of Melbourne, Melbourne, VIC, Australia
| | - Radouil Tzekov
- Department of Ophthalmology, University of South Florida, Tampa, FL, USA
| | | |
Collapse
|
23
|
Electroretinography in idiopathic intracranial hypertension: comparison of the pattern ERG and the photopic negative response. Doc Ophthalmol 2017; 136:45-55. [PMID: 29139045 DOI: 10.1007/s10633-017-9620-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Accepted: 11/02/2017] [Indexed: 10/18/2022]
Abstract
PURPOSE To evaluate the relationship between electrophysiological measures of retinal ganglion cell (RGC) function in patients who have idiopathic intracranial hypertension (IIH). METHODS The pattern electroretinogram (pERG) and photopic negative response (PhNR) were recorded from 11 IIH patients and 11 age-similar controls. The pERG was elicited by a contrast-reversing checkerboard. The PhNR, a slow negative component following the flash ERG b-wave, was recorded in response to a long-wavelength flash presented against a short-wavelength adapting field. The PhNR was elicited using full-field (ffPhNR) and focal macular (fPhNR) stimuli. Additionally, Humphrey visual field mean deviation (HVF MD) was measured and ganglion cell complex volume (GCCV) was obtained by optical coherence tomography. RESULTS The ffPhNR, fPhNR, and pERG amplitudes were outside of the normal range in 45, 9, and 45% of IIH patients, respectively. However, only mean ffPhNR amplitude was reduced significantly in the patients compared to controls (p < 0.01). The pERG amplitude correlated significantly with HVF MD and GCCV (both r > 0.65, p < 0.05). There were associations between ffPhNR amplitude and HVF MD (r = 0.58, p = 0.06) and with GCCV (r = 0.52, p = 0.10), but these did not reach statistical significance. fPhNR amplitude was not correlated significantly with HVF MD or GCCV (both r < 0.40, p > 0.20). CONCLUSIONS Although the fPhNR is generally normal in IIH, other electrophysiological measures of RGC function, the ffPhNR and pERG, are abnormal in some patients. These measures provide complementary information regarding RGC dysfunction in these individuals.
Collapse
|
24
|
Ba-Ali S, Lund-Andersen H. Pupillometric evaluation of the melanopsin containing retinal ganglion cells in mitochondrial and non-mitochondrial optic neuropathies. Mitochondrion 2017; 36:124-129. [PMID: 28716667 DOI: 10.1016/j.mito.2017.07.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 05/29/2017] [Accepted: 07/13/2017] [Indexed: 01/08/2023]
Abstract
In recent years, chromatic pupillometry is used in humans to evaluate the activity of melanopsin expressing intrinsic photosensitive retinal ganglion cells (ipRGCs). Blue light is used to stimulate the ipRGCs and red light activates the rod/cone photoreceptors. The late re-dilation phase of pupillary light reflex is primarily driven by the ipRGCs. Optic neuropathies i.e. Leber hereditary optic neuropathy (LHON), autosomal dominant optic atrophy (ADOA), nonarteritic anterior ischemic optic neuropathy (NAION), glaucoma, optic neuritis and idiopathic intracranial hypertension (IIH) are among the diseases, which have been subject to pupillometric studies. The ipRGCs are differentially affected in these various optic neuropathies. In mitochondrial optic neuropathies, the ipRGCs are protected against degeneration, whereas in glaucoma, NAION, optic neuritis and IIH the ipRGCs are damaged. Here, we will review the results of pupillometric, histopathological and animal studies evaluating the ipRGCs in mitochondrial and non-mitochondrial optic neuropathies.
Collapse
Affiliation(s)
- Shakoor Ba-Ali
- Department of Ophthalmology, Rigshospitalet, Glostrup, Denmark; Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
| | - Henrik Lund-Andersen
- Department of Ophthalmology, Rigshospitalet, Glostrup, Denmark; Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
25
|
Joshi NR, Ly E, Viswanathan S. Intensity response function of the photopic negative response (PhNR): effect of age and test-retest reliability. Doc Ophthalmol 2017; 135:1-16. [PMID: 28508299 DOI: 10.1007/s10633-017-9591-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 05/03/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE To assess the effect of age and test-retest reliability of the intensity response function of the full-field photopic negative response (PhNR) in normal healthy human subjects. METHODS Full-field electroretinograms (ERGs) were recorded from one eye of 45 subjects, and 39 of these subjects were tested on two separate days with a Diagnosys Espion System (Lowell, MA, USA). The visual stimuli consisted of brief (<5 ms) red flashes ranging from 0.00625 to 6.4 phot cd.s/m2, delivered on a constant 7 cd/m2 blue background. PhNR amplitudes were measured at its trough from baseline (BT) and from the preceding b-wave peak (PT), and b-wave amplitude was measured at its peak from the preceding a-wave trough or baseline if the a-wave was not present. The intensity response data of all three ERG measures were fitted with a generalized Naka-Rushton function to derive the saturated amplitude (V max), semisaturation constant (K) and slope (n) parameters. Effect of age on the fit parameters was assessed with linear regression, and test-retest reliability was assessed with the Wilcoxon signed-rank test and Bland-Altman analysis. Holm's correction was applied to account for multiple comparisons. RESULTS V max of BT was significantly smaller than that of PT and b-wave, and the V max of PT and b-wave was not significantly different from each other. The slope parameter n was smallest for BT and the largest for b-wave and the difference between the slopes of all three measures were statistically significant. Small differences observed in the mean values of K for the different measures did not reach statistical significance. The Wilcoxon signed-rank test indicated no significant differences between the two test visits for any of the Naka-Rushton parameters for the three ERG measures, and the Bland-Altman plots indicated that the mean difference between test and retest measurements of the different fit parameters was close to zero and within 6% of the average of the test and retest values of the respective parameters for all three ERG measurements, indicating minimal bias. While the coefficient of reliability (COR, defined as 1.96 times the standard deviation of the test and retest difference) of each fit parameter was more or less comparable across the three ERG measurements, the %COR (COR normalized to the mean test and retest measures) was generally larger for BT compared to both PT and b-wave for each fit parameter. The Naka-Rushton fit parameters did not show statistically significant changes with age for any of the ERG measures when corrections were applied for multiple comparisons. However, the V max of BT demonstrated a weak correlation with age prior to correction for multiple comparisons, and the effect of age on this parameter showed greater significance when the measure was expressed as a ratio of the V max of b-wave from the same subject. CONCLUSION V max of the BT amplitude measure of PhNR at the best was weakly correlated with age. None of the other parameters of the Naka-Rushton fit to the intensity response data of either the PhNR or the b-wave showed any systematic changes with age. The test-retest reliability of the fit parameters for PhNR BT amplitude measurements appears to be lower than those of the PhNR PT and b-wave amplitude measurements.
Collapse
Affiliation(s)
- Nabin R Joshi
- College of Optometry, State University of New York, 33 West 42nd Street, New York, NY, 10036, USA
| | - Emma Ly
- Southern California College of Optometry, Marshall B. Ketchum University, Fullerton, CA, USA
| | - Suresh Viswanathan
- College of Optometry, State University of New York, 33 West 42nd Street, New York, NY, 10036, USA.
| |
Collapse
|
26
|
Kundra H, Park JC, McAnany JJ. Comparison of photopic negative response measurements in the time and time-frequency domains. Doc Ophthalmol 2016; 133:91-98. [PMID: 27562839 DOI: 10.1007/s10633-016-9558-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Accepted: 08/15/2016] [Indexed: 11/30/2022]
Abstract
PURPOSE To compare measurements of the full-field photopic negative response (PhNR), as well as intra-subject variation in the PhNR, using time and time-frequency domain analyses. METHODS Full-field ERGs were recorded from 20 normally sighted subjects (aged 24-65 years) elicited by a long-wavelength pulse (3 cd s m-2) presented against a short-wavelength adapting field (12.5 cd m-2). Three to 10 waveforms were obtained from each subject, and each waveform was analyzed using standard time domain analyses of the PhNR, as well as a discrete wavelet transform (DWT) to extract time-frequency components that correspond to the PhNR. Three different measures of the PhNR were derived and compared: (1) amplitude at the PhNR trough; (2) amplitude at 72 ms following stimulus onset; (3) energy in the 11 Hz, 60-120 ms DWT frequency bin that corresponds to the PhNR. In addition, the effect of normalizing the PhNR by the b-wave was evaluated for each of the measures. Coefficients of variation (CVs) were computed for each definition to evaluate intra-subject variation. RESULTS PhNR amplitudes measured at the trough and at 72 ms were significantly correlated (r = 0.88, p < 0.001). Additionally, PhNR energy derived by DWT was significantly correlated with the amplitude measured at the trough (r = 0.64, p = 0.002) and at 72 ms (r = 0.60, p = 0.005). Mean (±SD) intra-subject CVs were 26 % (15 %), 49 % (26 %), and 30 % (15 %), for measures at the trough, 72 ms, and DWT, respectively. Normalization by the b-wave amplitude (i.e., PhNR/b) had minimal effect on the intra-subject CVs, whereas normalization by the sum of the b-wave and PhNR amplitudes (i.e., PhNR/[b + PhNR]) substantially reduced the CVs for all three measures (mean CVs were less than 17 % for all conditions). CONCLUSIONS Although each PhNR definition has advantages and disadvantages, all three metrics provide similar estimates of the PhNR. Intra-subject CVs, however, were relatively high for measurements made at 72 ms, indicating that definitions based on a fixed time point may introduce variability. The substantial decrease in intra-subject variation after normalization by the sum of the PhNR and b-wave amplitudes may be advantageous under some conditions.
Collapse
Affiliation(s)
- Hansa Kundra
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., Chicago, IL, 60612, USA.,Department of Bioengineering, University of Illinois at Chicago, 851 South Morgan St., Chicago, IL, 60607, USA
| | - Jason C Park
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., Chicago, IL, 60612, USA
| | - J Jason McAnany
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 W. Taylor St., Chicago, IL, 60612, USA. .,Department of Bioengineering, University of Illinois at Chicago, 851 South Morgan St., Chicago, IL, 60607, USA. .,Department of Psychology, University of Illinois at Chicago, 1007 W. Harrison St., Chicago, IL, 60612, USA.
| |
Collapse
|
27
|
Sebag J, Sadun AA, Pierce EA. Paradigm Shifts in Ophthalmic Diagnostics. TRANSACTIONS OF THE AMERICAN OPHTHALMOLOGICAL SOCIETY 2016; 114:WP1. [PMID: 28008209 PMCID: PMC5141845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE Future advances in ophthalmology will see a paradigm shift in diagnostics from a focus on dysfunction and disease to better measures of psychophysical function and health. Practical methods to define genotypes will be increasingly important and non-invasive nanotechnologies are needed to detect molecular changes that predate histopathology. METHODS This is not a review nor meant to be comprehensive. Specific topics have been selected to illustrate the principles of important paradigm shifts that will influence the future of ophthalmic diagnostics. It is our impression that future evaluation of vision will go beyond visual acuity to assess ocular health in terms of psychophysical function. The definition of disease will incorporate genotype into what has historically been a phenotype-centric discipline. Non-invasive nanotechnologies will enable a paradigm shift from disease detection on a cellular level to a sub-cellular molecular level. RESULTS Vision can be evaluated beyond visual acuity by measuring contrast sensitivity, color vision, and macular function, as these provide better insights into the impact of aging and disease. Distortions can be quantified and the psychophysical basis of vision can be better evaluated than in the past by designing tests that assess particular macular cell function(s). Advances in our understanding of the genetic basis of eye diseases will enable better characterization of ocular health and disease. Non-invasive nanotechnologies can assess molecular changes in the lens, vitreous, and macula that predate visible pathology. Oxygen metabolism and circulatory physiology are measurable indices of ocular health that can detect variations of physiology and early disease. CONCLUSIONS This overview of paradigm shifts in ophthalmology suggests that the future will see significant improvements in ophthalmic diagnostics. The selected topics illustrate the principles of these paradigm shifts and should serve as a guide to further research and development. Indeed, successful implementation of these paradigm shifts in ophthalmology may provide useful guidance for similar developments in all of healthcare.
Collapse
Affiliation(s)
- J Sebag
- Dr. Sebag: VMR Institute for Vitreous Macula Retina, Huntington Beach, CA; Dr. Sadun: Doheny Eye Institute/UCLA, Los Angeles, CA; Dr. Pierce: Ocular Genomics Institute, Massachusetts Eye and Ear Infirmary, Harvard Medical School
| | - Alfredo A Sadun
- Dr. Sebag: VMR Institute for Vitreous Macula Retina, Huntington Beach, CA; Dr. Sadun: Doheny Eye Institute/UCLA, Los Angeles, CA; Dr. Pierce: Ocular Genomics Institute, Massachusetts Eye and Ear Infirmary, Harvard Medical School
| | - Eric A Pierce
- Dr. Sebag: VMR Institute for Vitreous Macula Retina, Huntington Beach, CA; Dr. Sadun: Doheny Eye Institute/UCLA, Los Angeles, CA; Dr. Pierce: Ocular Genomics Institute, Massachusetts Eye and Ear Infirmary, Harvard Medical School
| |
Collapse
|
28
|
Abstract
Visual function is an important parameter to consider when managing patients with papilledema. Though the current standard of care uses standard automated perimetry (SAP) to obtain this information, this test is inherently subjective and prone to patient errors. Objective visual function tests including the visual evoked potential, pattern electroretinogram, photopic negative response of the full field electroretinogram, and pupillary light response have the potential to replace or supplement subjective visual function tests in papilledema management. This article reviews the evidence for use of objective visual function tests to assess visual function in papilledema and discusses future investigations needed to develop them as clinically practical and useful measures for this purpose.
Collapse
Affiliation(s)
- Heather E Moss
- Department of Ophthalmology & Visual Sciences, Department of Neurology & Rehabilitation, University of Illinois at Chicago, Chicago, IL
| |
Collapse
|
29
|
Park JC, Moss HE, McAnany JJ. The Pupillary Light Reflex in Idiopathic Intracranial Hypertension. Invest Ophthalmol Vis Sci 2016; 57:23-9. [PMID: 26746015 PMCID: PMC4713014 DOI: 10.1167/iovs.15-18181] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Purpose To evaluate the effects of idiopathic intracranial hypertension (IIH) on rod-, cone-, and melanopsin-mediated pupillary light reflexes (PLRs). Methods Pupillary light reflexes elicited by full-field, brief-flash stimuli were recorded in 13 IIH patients and 13 normal controls. Subjects were dark-adapted for 10 minutes and the PLR was recorded in response to short-wavelength flashes (0.001 cd/m2: rod condition; 450 cd/m2: melanopsin condition). Subjects were then exposed to a rod-suppressing field and 10 cd/m2 long-wavelength flashes were presented (cone condition). Pupillary light reflexes were quantified as the maximum transient constriction (rod and cone conditions) and the post-illumination pupil constriction (melanopsin condition), relative to the baseline pupil size. Diagnostic power was evaluated using receiver operating characteristic (ROC) analysis. Results The IIH patients had significantly smaller PLRs under the melanopsin (P < 0.001) and rod (P = 0.04) paradigms; a trend for reduced cone-mediated PLRs was also found (P = 0.08). Receiver operating characteristic analysis indicated areas under the curves (AUC) of 0.83 (melanopsin-meditated; P = 0.001), 0.71 (rod-mediated; P = 0.07), and 0.77 (cone-mediated; P = 0.02). The AUC (0.90, P < 0.001), sensitivity (85%), and specificity (85%) were high for ROC analysis performed on the mean of the rod, cone, and melanopsin PLRs. Conclusions Pupillary light reflex reductions in IIH patients indicate compromised RGC function. PLR measurement, particularly under rod- and melanopsin-mediated conditions, may be a useful adjunct to standard clinical measures of visual function in IIH.
Collapse
Affiliation(s)
- Jason C Park
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois, United States
| | - Heather E Moss
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois, United States 2Department of Neurology & Rehabilitation, University of Illinois at Chicago, Chicago, Illinois, United States
| | - J Jason McAnany
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois, United States 3Department of Psychology, University of Illinois at Chicago, Chicago, Illinois, United States 4Department of Bioengineering, University o
| |
Collapse
|