1
|
Tarhan M, Meller D, Hammer M. Hyperautofluorescent material inside areas of macular atrophy may reveal non-lipofuscin fluorophores in late stage AMD. Acta Ophthalmol 2024. [PMID: 39177106 DOI: 10.1111/aos.16752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 08/08/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE To characterize fundus autofluorescence (FAF) in complete (cRORA) and incomplete retinal pigment epithelium and outer retinal atrophy (iRORA) by fluorescence lifetime imaging ophthalmology (FLIO). METHODS Overall, 98 macular atrophy (MA) lesions in 42 eyes of 37 age-related macular degeneration (AMD) patients (mean age: 80.9 ± 5.8 years), 25 of them classified as iRORA and 73 as cRORA by OCT, were investigated by FLIO in a short (SSC: 498-560 nm) and a long wavelength channel (LSC: 560-720 nm). Differences of FAF lifetimes and peak emission wavelength (PEW) between atrophic lesions and intact retinal pigment epithelium (RPE) in the outer ring of the ETDRS grid were considered. RESULTS FAF lifetimes in MA were longer and PEW were significantly (p < 0.001) shorter than in intact RPE by 112 ± 78 ps (SSC), 91 ± 64 ps (LSC), 27 ± 18 nm (PEW) in iRORA and by 227 ± 112 ps (SSC), 167 ± 81 ps (LSC), and 54 ± 17 nm (PEW) in cRORA. 37% of iRORA and 24% of cRORA were hyperautofluorescent in SSC. Persistent sub-RPE-BL material in MA was newly found as a hyperautofluorescent entity with lifetimes considerably longer than that of drusen and RPE. CONCLUSIONS Despite RPE and, thus, lipofuscin are greatly absent in MA, considerable FAF, preferably at short wavelengths, was found in those lesions. Drusen, persistent sub-RPE-BL material, basal laminar deposits, persistent activated RPE, and sclera were identified as putative sources of this fluorescence. FLIO can help to characterize respective fluorophores.
Collapse
Affiliation(s)
- Melih Tarhan
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Daniel Meller
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Martin Hammer
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
- Center for Medical Optics and Photonics, University of Jena, Jena, Germany
| |
Collapse
|
2
|
Kunala K, Tang JAH, Parkins K, Hunter JJ. Multispectral label-free in vivo cellular imaging of human retinal pigment epithelium using adaptive optics fluorescence lifetime ophthalmoscopy improves feasibility for low emission analysis and increases sensitivity for detecting changes with age and eccentricity. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S22707. [PMID: 38962492 PMCID: PMC11221116 DOI: 10.1117/1.jbo.29.s2.s22707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 04/25/2024] [Accepted: 04/26/2024] [Indexed: 07/05/2024]
Abstract
Significance Adaptive optics fluorescence lifetime ophthalmoscopy (AOFLIO) provides a label-free approach to observe functional and molecular changes at cellular scale in vivo. Adding multispectral capabilities improves interpretation of lifetime fluctuations due to individual fluorophores in the retinal pigment epithelium (RPE). Aim To quantify the cellular-scale changes in autofluorescence with age and eccentricity due to variations in lipofuscin, melanin, and melanolipofuscin in RPE using multispectral AOFLIO. Approach AOFLIO was performed on six subjects at seven eccentricities. Four imaging channels (λ ex / λ em ) were used: 473/SSC, 473/LSC, 532/LSC, and 765/NIR. Cells were segmented and the timing signals of each pixel in a cell were combined into a single histogram, which were then used to compute the lifetime and phasor parameters. An ANOVA was performed to investigate eccentricity and spectral effects on each parameter. Results A repeatability analysis revealed < 11.8 % change in lifetime parameters in repeat visits for 532/LSC. The 765/NIR and 532/LSC had eccentricity and age effects similar to previous reports. The 473/LSC had a change in eccentricity with mean lifetime and a phasor component. Both the 473/LSC and 473/SSC had changes in eccentricity in the short lifetime component and its relative contribution. The 473/SSC had no trend in eccentricity in phasor. The comparison across the four channels showed differences in lifetime and phasor parameters. Conclusions Multispectral AOFLIO can provide a more comprehensive picture of changes with age and eccentricity. These results indicate that cell segmentation has the potential to allow investigations in low-photon scenarios such as in older or diseased subjects with the co-capture of an NIR channel (such as 765/NIR) with the desired spectral channel. This work represents the first multispectral, cellular-scale fluorescence lifetime comparison in vivo in the human RPE and may be a useful method for tracking diseases.
Collapse
Affiliation(s)
- Karteek Kunala
- Stanford University, Byers Eye Institute, Palo Alto, California, United States
| | - Janet A. H. Tang
- University of Rochester, Center for Visual Science, Rochester, New York, United States
- University of Rochester, The Institute of Optics, Rochester, New York, United States
| | - Keith Parkins
- University of Rochester, Center for Visual Science, Rochester, New York, United States
| | - Jennifer J. Hunter
- University of Rochester, Center for Visual Science, Rochester, New York, United States
- University of Rochester, The Institute of Optics, Rochester, New York, United States
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Ontario, Canada
| |
Collapse
|
3
|
Kunala K, Tang JAH, Bowles Johnson KE, Huynh KT, Parkins K, Kim HJ, Yang Q, Sparrow JR, Hunter JJ. Near Infrared Autofluorescence Lifetime Imaging of Human Retinal Pigment Epithelium Using Adaptive Optics Scanning Light Ophthalmoscopy. Invest Ophthalmol Vis Sci 2024; 65:27. [PMID: 38758638 PMCID: PMC11107951 DOI: 10.1167/iovs.65.5.27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 04/23/2024] [Indexed: 05/19/2024] Open
Abstract
Purpose To demonstrate the first near-infrared adaptive optics fluorescence lifetime imaging ophthalmoscopy (NIR-AOFLIO) measurements in vivo of the human retinal pigment epithelial (RPE) cellular mosaic and to visualize lifetime changes at different retinal eccentricities. Methods NIR reflectance and autofluorescence were captured using a custom adaptive optics scanning light ophthalmoscope in 10 healthy subjects (23-64 years old) at seven eccentricities and in two eyes with retinal abnormalities. Repeatability was assessed across two visits up to 8 weeks apart. Endogenous retinal fluorophores and hydrophobic whole retinal extracts of Abca4-/- pigmented and albino mice were imaged to probe the fluorescence origin of NIR-AOFLIO. Results The RPE mosaic was resolved at all locations in five of seven younger subjects (<35 years old). The mean lifetime across near-peripheral regions (8° and 12°) was longer compared to near-foveal regions (0° and 2°). Repeatability across two visits showed moderate to excellent correlation (intraclass correlation: 0.88 [τm], 0.75 [τ1], 0.65 [τ2], 0.98 [a1]). The mean lifetime across drusen-containing eyes was longer than in age-matched healthy eyes. Fluorescence was observed in only the extracts from pigmented Abca4-/- mouse. Conclusions NIR-AOFLIO was repeatable and allowed visualization of the RPE cellular mosaic. An observed signal in only the pigmented mouse extract infers the fluorescence signal originates predominantly from melanin. Variations observed across the retina with intermediate age-related macular degeneration suggest NIR-AOFLIO may act as a functional measure of a biomarker for in vivo monitoring of early alterations in retinal health.
Collapse
Affiliation(s)
- Karteek Kunala
- Center for Visual Science, University of Rochester, Rochester, New York, United States
- Byers Eye Institute, Stanford University, Palo Alto, California, United States
| | - Janet A. H. Tang
- Center for Visual Science, University of Rochester, Rochester, New York, United States
- The Institute of Optics, University of Rochester, Rochester, New York, United States
| | - Kristen E. Bowles Johnson
- Center for Visual Science, University of Rochester, Rochester, New York, United States
- Flaum Eye Institute, University of Rochester, Rochester, New York, United States
- School of Optometry, Indiana University, Bloomington, Indiana, United States
| | - Khang T. Huynh
- Center for Visual Science, University of Rochester, Rochester, New York, United States
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States
- Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, Berkeley, California, United States
| | - Keith Parkins
- Center for Visual Science, University of Rochester, Rochester, New York, United States
| | - Hye-Jin Kim
- College of Pharmacy, Keimyung University, Dalseo-gu, Daegu, South Korea
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
| | - Qiang Yang
- Center for Visual Science, University of Rochester, Rochester, New York, United States
| | - Janet R. Sparrow
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
| | - Jennifer J. Hunter
- Center for Visual Science, University of Rochester, Rochester, New York, United States
- Flaum Eye Institute, University of Rochester, Rochester, New York, United States
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
4
|
Curcio CA, Kar D, Owsley C, Sloan KR, Ach T. Age-Related Macular Degeneration, a Mathematically Tractable Disease. Invest Ophthalmol Vis Sci 2024; 65:4. [PMID: 38466281 PMCID: PMC10916886 DOI: 10.1167/iovs.65.3.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 02/19/2024] [Indexed: 03/12/2024] Open
Abstract
A progression sequence for age-related macular degeneration onset may be determinable with consensus neuroanatomical nomenclature augmented by drusen biology and eye-tracked clinical imaging. This narrative review proposes to supplement the Early Treatment of Diabetic Retinopathy Study (sETDRS) grid with a ring to capture high rod densities. Published photoreceptor and retinal pigment epithelium (RPE) densities in flat mounted aged-normal donor eyes were recomputed for sETDRS rings including near-periphery rich in rods and cumulatively for circular fovea-centered regions. Literature was reviewed for tissue-level studies of aging outer retina, population-level epidemiology studies regionally assessing risk, vision studies regionally assessing rod-mediated dark adaptation (RMDA), and impact of atrophy on photopic visual acuity. The 3 mm-diameter xanthophyll-rich macula lutea is rod-dominant and loses rods in aging whereas cone and RPE numbers are relatively stable. Across layers, the largest aging effects are accumulation of lipids prominent in drusen, loss of choriocapillary coverage of Bruch's membrane, and loss of rods. Epidemiology shows maximal risk for drusen-related progression in the central subfield with only one third of this risk level in the inner ring. RMDA studies report greatest slowing at the perimeter of this high-risk area. Vision declines precipitously when the cone-rich central subfield is invaded by geographic atrophy. Lifelong sustenance of foveal cone vision within the macula lutea leads to vulnerability in late adulthood that especially impacts rods at its perimeter. Adherence to an sETDRS grid and outer retinal cell populations within it will help dissect mechanisms, prioritize research, and assist in selecting patients for emerging treatments.
Collapse
Affiliation(s)
- Christine A. Curcio
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham Heersink School of Medicine, Birmingham, Alabama, United States
| | - Deepayan Kar
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham Heersink School of Medicine, Birmingham, Alabama, United States
| | - Cynthia Owsley
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham Heersink School of Medicine, Birmingham, Alabama, United States
| | - Kenneth R. Sloan
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham Heersink School of Medicine, Birmingham, Alabama, United States
| | - Thomas Ach
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
5
|
Schweitzer D, Haueisen J, Klemm M. Suppression of natural lens fluorescence in fundus autofluorescence measurements: review of hardware solutions. BIOMEDICAL OPTICS EXPRESS 2022; 13:5151-5170. [PMID: 36425615 PMCID: PMC9664869 DOI: 10.1364/boe.462559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/25/2022] [Accepted: 07/25/2022] [Indexed: 06/16/2023]
Abstract
Fluorescence lifetime imaging ophthalmoscopy (FLIO), a technique for investigating metabolic changes in the eye ground, can reveal the first signs of diseases related to metabolism. The fluorescence of the natural lens overlies the fundus fluorescence. Although the influence of natural lens fluorescence can be somewhat decreased with mathematical models, excluding this influence during the measurement by using hardware enables more exact estimation of the fundus fluorescence. Here, we analyze four 1-photon excitation hardware solutions to suppress the influence of natural lens fluorescence: aperture stop separation, confocal scanning laser ophthalmoscopy, combined confocal scanning laser ophthalmoscopy and aperture stop separation, and dual point confocal scanning laser ophthalmoscopy. The effect of each principle is demonstrated in examples. The best suppression is provided by the dual point principle, realized with a confocal scanning laser ophthalmoscope. In this case, in addition to the fluorescence of the whole eye, the fluorescence of the anterior part of the eye is detected from a non-excited spot of the fundus. The intensity and time-resolved fluorescence spectral data of the fundus are derived through the subtraction of the simultaneously measured fluorescence of the excited and non-excited spots. Advantages of future 2-photon fluorescence excitation are also discussed. This study provides the first quantitative evaluation of hardware principles to suppress the fluorescence of the natural lens during measurements of fundus autofluorescence.
Collapse
Affiliation(s)
- D. Schweitzer
- Department of Ophthalmology, University Hospital Jena, Am Klinikum 1, 07747 Jena, Germany
| | - J. Haueisen
- Institute of Biomedical Engineering and Informatics, POB 100565, 98694 Ilmenau, Germany
| | - M. Klemm
- Institute of Biomedical Engineering and Informatics, POB 100565, 98694 Ilmenau, Germany
| |
Collapse
|
6
|
Tang JAH, Granger CE, Kunala K, Parkins K, Huynh KT, Bowles-Johnson K, Yang Q, Hunter JJ. Adaptive optics fluorescence lifetime imaging ophthalmoscopy of in vivo human retinal pigment epithelium. BIOMEDICAL OPTICS EXPRESS 2022; 13:1737-1754. [PMID: 35414970 PMCID: PMC8973160 DOI: 10.1364/boe.451628] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 02/11/2022] [Accepted: 02/14/2022] [Indexed: 05/18/2023]
Abstract
The intrinsic fluorescence properties of lipofuscin - naturally occurring granules that accumulate in the retinal pigment epithelium - are a potential biomarker for the health of the eye. A new modality is described here which combines adaptive optics technology with fluorescence lifetime detection, allowing for the investigation of functional and compositional differences within the eye and between subjects. This new adaptive optics fluorescence lifetime imaging ophthalmoscope was demonstrated in 6 subjects. Repeated measurements between visits had a minimum intraclass correlation coefficient of 0.59 Although the light levels were well below maximum permissible exposures, the safety of the imaging paradigm was tested using clinical measures; no concerns were raised. This new technology allows for in vivo adaptive optics fluorescence lifetime imaging of the human RPE mosaic.
Collapse
Affiliation(s)
- Janet A. H. Tang
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Contributed equally
| | - Charles E. Granger
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Contributed equally
| | - Karteek Kunala
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Keith Parkins
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Khang T. Huynh
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Kristen Bowles-Johnson
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Flaum Eye Institute, University of Rochester, Rochester, NY 14627, USA
| | - Qiang Yang
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Jennifer J. Hunter
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Flaum Eye Institute, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|