1
|
Ye ZT, Tseng SF, Tsou SX, Tsai CW. Spectral analysis with highly collimated mini-LEDs as light sources for quantitative detection of direct bilirubin. DISCOVER NANO 2024; 19:13. [PMID: 38238545 PMCID: PMC10796896 DOI: 10.1186/s11671-024-03957-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 01/11/2024] [Indexed: 01/22/2024]
Abstract
Because the human eye cannot visually detect the results of direct bilirubin test papers accurately and quantitatively, this study proposes four different highly collimated mini light-emitting diodes (HC mini-LEDs) as light sources for detection. First, different concentrations of bilirubin were oxidized to biliverdin by FeCl3 on the test paper, and pictures were obtained with a smartphone. Next, the red, green, and blue (RGB) channels of the pictures were separated to average grayscale values, and their linear relationship with the direct bilirubin concentration was analyzed to detect bilirubin on the test paper noninvasively and quantitatively. The experimental results showed that when green HC mini-LEDs were used as the light sources and image analysis was performed using the G channel, for a direct bilirubin concentration range of 0.1-2 mg/dL, the G channel determination coefficient (R2) reached 0.9523 and limit of detection was 0.459 mg/dL. The detection method proposed herein has advantages such as rapid analysis, noninvasive detection, and digitization according to RGB grayscale changes in the images of the detection test paper.
Collapse
Affiliation(s)
- Zhi Ting Ye
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High-Tech Innovations, National Chung Cheng University, 168, University Rd., Min-Hsiung, Chia-Yi, 62102, Taiwan, ROC.
| | - Shen Fu Tseng
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High-Tech Innovations, National Chung Cheng University, 168, University Rd., Min-Hsiung, Chia-Yi, 62102, Taiwan, ROC
| | - Shang Xuan Tsou
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High-Tech Innovations, National Chung Cheng University, 168, University Rd., Min-Hsiung, Chia-Yi, 62102, Taiwan, ROC
| | - Chun Wei Tsai
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No. 1, Sec. 4, Roosevelt Rd., Taipei, 106319, Taiwan, ROC.
| |
Collapse
|
2
|
Arioka M, Koyano K, Nakao Y, Ozaki M, Nakamura S, Kiuchi H, Okada H, Itoh S, Murao K, Kusaka T. Quantitative effects of bilirubin structural photoisomers on the measurement of direct bilirubin via the vanadate oxidation method. Ann Clin Biochem 2023; 60:177-183. [PMID: 36772822 DOI: 10.1177/00045632231154748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
BACKGROUND Exposing blood serum samples to ambient white light-emitting diode (WLED) light may accelerate bilirubin photoisomer production. We previously demonstrated the quantitative effect of bilirubin configurational isomers (BCI) on direct bilirubin (DB) value using the vanadate oxidation method. However, the effects of bilirubin structural photoisomers (BSI) remain unclear. METHODS In Study 1, the relationship between WLED irradiation time and BSI production was examined. Serum samples from five neonates were irradiated with WLED light for 0, 10, 30, 60 and 180 min. Bilirubin isomer concentration and BSI production rates were calculated. In Study 2, we performed quantitative investigation of BSI effect on DB values: Differences in DB, BCI and BSI values before and after irradiation were calculated as ⊿DB, ⊿BCI and ⊿BSI, respectively. Assuming the coefficient of BCI affecting DB values was 'a', relational expression was ⊿DB = a*⊿BSI + 0.19*⊿BCI. Serum samples from 15 neonates were irradiated with green LED light for 10 and 30 s. The respective bilirubin isomer levels were measured, and the coefficient was derived. RESULTS In Study 1, the median BSI production rate was 0.022 mg/dL per min in specimens with an unconjugated bilirubin concentration of 10.88 mg/dL. In Study 2, assuming that ⊿DB-0.19*⊿BCI was Y and ⊿BSI was X, the relational expression was Y = 0.34X-0.03 (R2 = 0.87; p < .01) and a = 0.34. CONCLUSIONS Under ambient WLED light, serum sample generated 1.3 mg/dL BSIs in 1 h. Approximately 34% (0.44 mg/dL) of BSI concentrations was measured as DB when using the vanadate oxidation method according to the above equation.
Collapse
Affiliation(s)
- Makoto Arioka
- Department of Pediatrics, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Kosuke Koyano
- Department of Pediatrics, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Yasuhiro Nakao
- Department of Pediatrics, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Miyo Ozaki
- Department of Clinical Laboratory, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Shinji Nakamura
- Department of Pediatrics, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Hiroyuki Kiuchi
- Department of Clinical Laboratory, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Hitoshi Okada
- Department of Medical Technology, Kagawa Prefectural University of Health Sciences, Kagawa, Japan
| | - Susumu Itoh
- Department of Pediatrics, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Koji Murao
- Department of Clinical Laboratory, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| | - Takashi Kusaka
- Department of Pediatrics, Faculty of Medicine, 12850Kagawa University, Kagawa, Japan
| |
Collapse
|
3
|
Ye ZT, Kuo HC, Tseng SF, Chung SR, Tsou SX. Using Blue Mini-LEDs as a Light Source Designed a Miniaturized Optomechanical Device for the Detection of Direct Bilirubin. NANOSCALE RESEARCH LETTERS 2022; 17:111. [PMID: 36417033 PMCID: PMC9684399 DOI: 10.1186/s11671-022-03750-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 11/15/2022] [Indexed: 05/30/2023]
Abstract
This study developed a miniaturized optomechanical device (MOD) for the feasibility study of direct bilirubin in urine using high-collimation blue mini-light-emitting diodes (Mini-LEDs) as the light source. The constructed MOD used optical spectroscopy to analyze different concentrations of direct bilirubin using the absorbance spectrum to achieve a noninvasive method for detection. The experimental results showed that between the absorbance and different concentrations of direct bilirubin at the blue Mini-LEDs central wavelength (462 nm) was the optimum fitting wavelength; in the direct bilirubin concentration range from 0.855 to 17.1 μmol/L, the coefficient of determination (R2) was 0.9999, the limit of detection (LOD) of 0.171 μmol/L, and the limit of quantitation (LOQ) of 0.570 μmol/L. Therefore, we propose using blue Mini-LEDs as a light source to design a MOD to replace the invasive blood sampling method with a spectroscopic detection of direct bilirubin concentration corresponding to absorbance.
Collapse
Affiliation(s)
- Zhi Ting Ye
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High-Tech Innovations, National Chung Cheng University, 168, University Rd., Min-Hsiung, Chia-Yi, 62102 Taiwan, ROC
| | - Hsin-Ching Kuo
- Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chia-Yi, Taiwan, ROC
| | - Shen Fu Tseng
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High-Tech Innovations, National Chung Cheng University, 168, University Rd., Min-Hsiung, Chia-Yi, 62102 Taiwan, ROC
| | - Shu-Ru Chung
- Department of Materials Science and Engineering, National Formosa University, No. 64, Wunhua Rd., Huwei Township, 632 Yunlin County Taiwan, ROC
| | - Shang-Xuan Tsou
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High-Tech Innovations, National Chung Cheng University, 168, University Rd., Min-Hsiung, Chia-Yi, 62102 Taiwan, ROC
| |
Collapse
|
4
|
Kiuchi S, Ihara H, Osawa S, Ishibashi M, Kinpara K, Ohtake K, Ida T, Miura Y, Fujimura Y, Ueda S, Hirano Y, Watahiki K, Takada D, Shinzaki A, Tanimoto K, Adachi H, Nejime T, Totani M, Itoh S. A survey of the reactivity of in vitro diagnostic bilirubin reagents developed in Japan using artificially prepared bilirubin materials: A comparison of synthetic delta, unconjugated, and taurine-conjugated bilirubin. Ann Clin Biochem 2021; 58:563-571. [PMID: 34120480 DOI: 10.1177/00045632211026699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND In vitro diagnostic bilirubin reagents based on oxidation with bilirubin oxidase or vanadic acid for total and direct-reacting bilirubin are widely used in Japan; however, their reactivity to unconjugated and conjugated bilirubin and delta bilirubin has not been completely disclosed by manufacturers. We used artificially prepared bilirubin materials to investigate the reactivity with four in vitro diagnostic bilirubin reagents. METHODS Porcine unconjugated bilirubin solution, chemically synthesized ditaurobilirubin solution, and chemically synthesized delta bilirubin solution were used as surrogates of naturally occurring unconjugated bilirubin, conjugated bilirubin, and delta bilirubin, respectively. The total bilirubin and direct-reacting bilirubin concentrations were measured by three bilirubin oxidase methods and one vanadic acid method, and the observed concentrations were compared with those obtained by the diazo-based reference measurement procedure. RESULTS The unconjugated bilirubin and delta bilirubin concentrations were similar when any of the four in vitro diagnostic bilirubin reagents were used during total bilirubin measurement. This was consistent with reference measurement procedure and exhibited a converged inter-method variation. Compared with reference measurement procedure, significantly low ditaurobilirubin concentrations were observed by the in vitro diagnostic bilirubin reagents despite the converged inter-method variation. In delta bilirubin measurement, some reagents reacted doubtfully with unconjugated bilirubin, while showed lower ditaurobilirubin concentrations than its corresponding total bilirubin concentration. Reactivity with delta bilirubin was different for each method including reference measurement procedure. Some reagents were developed to react less with delta bilirubin and others to strongly react with delta bilirubin. CONCLUSIONS We revealed the reactivity of IVD-TB and IVD-DB reagents to artificially prepared bilirubin materials, and their consistency with reference measurement procedure. The delta bilirubin data results vary depending on the reagents used.
Collapse
Affiliation(s)
- Sachiko Kiuchi
- Faculty of Risk and Crisis Management, Chiba Institute of Science, Chiba, Japan
| | - Hiroshi Ihara
- Faculty of Risk and Crisis Management, Chiba Institute of Science, Chiba, Japan
| | - Susumu Osawa
- Medical laboratory Sciences, Health Sciences, International University of Health and Welfare Graduate School, Chiba, Japan
| | | | - Kiyoko Kinpara
- Department of Clinical Laboratory, Toranomon Hospital, Tokyo, Japan
| | - Kazuko Ohtake
- Department of Laboratory Medicine, Keio University Hospital, Tokyo, Japan
| | - Takehisa Ida
- Central Laboratory, Saiseikai Chuwa Hospital, Nara, Japan
| | - Yoshinori Miura
- Department of Clinical Laboratory, Kitasato University Hospital, Kanagawa, Japan
| | - Yoshiyuki Fujimura
- Department of Clinical Laboratory, Kitasato University Hospital, Kanagawa, Japan
| | - Shigeru Ueda
- Faculty of Risk and Crisis Management, Chiba Institute of Science, Chiba, Japan
| | | | | | | | | | | | | | | | | | - Susumu Itoh
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | | |
Collapse
|
5
|
Kawamoto S, Koyano K, Ozaki M, Arai T, Iwase T, Okada H, Itoh S, Murao K, Kusaka T. Effects of bilirubin configurational photoisomers on the measurement of direct bilirubin by the vanadate oxidation method. Ann Clin Biochem 2021; 58:311-317. [PMID: 33588585 DOI: 10.1177/0004563221999068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Direct-reacting bilirubin concentrations measured using vanadate chemical oxidation method do not exactly match the conjugated bilirubin concentration. One of the causes is the effect of bilirubin photoisomers. However, the quantitative evaluation of the effects of these photoisomers has not been sufficiently conducted. In particular, the influence of bilirubin configurational isomers on direct bilirubin is the most critical factor. METHODS Sixteen residual serum samples were used. For quantitative analysis based on the change in direct bilirubin and bilirubin configurational isomer, samples were irradiated via blue light-emitting diodes to suppress the production of bilirubin structural isomers. Total bilirubin and direct bilirubin concentrations were measured using the vanadate chemical oxidation method. Concentrations of 4Z,15Z-bilirubin IXα and its photoisomers were measured using high-performance liquid chromatography. The sum of 4Z,15E-bilirubin IXα and 4E,15Z-bilirubin IXα was notated as bilirubin configurational isomer, and the differences between the measured values of the irradiated and non-irradiated samples were calculated and notated as ΔDB and ΔBCI. RESULTS In non-irradiated and irradiated samples, total bilirubin and direct bilirubin concentrations were 10.73 mg/dL with significant a decrease to 10.60 mg/dL and 0.69 mg/dL with a significant increase to 0.78 mg/dL, while bilirubin configurational isomer values were 1.00 mg/dL and 1.52 mg/dL, respectively. The linear regression equation revealed a significant positive correlation of Y = 0.187X-0.006 between ΔDB (Y) and ΔBCI (X). CONCLUSION Applying the vanadate chemical oxidation method affected approximately 19% of the bilirubin configurational isomer concentration for direct bilirubin. Extreme caution is necessary when interpreting the measured values of samples indicative of unconjugated hyperbilirubinaemia.
Collapse
Affiliation(s)
- Shohei Kawamoto
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Kosuke Koyano
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Miyo Ozaki
- Department of Clinical Laboratory, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Takeshi Arai
- Department of Clinical Laboratory, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Takashi Iwase
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Hitoshi Okada
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Susumu Itoh
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Koji Murao
- Department of Clinical Laboratory, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Takashi Kusaka
- Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan
| |
Collapse
|
6
|
Rodríguez CE. New method for the determination of the net bilirubin absorbance in cerebrospinal fluid that minimizes the interference of oxyhaemoglobin and biliverdin. Scandinavian Journal of Clinical and Laboratory Investigation 2019; 80:81-86. [PMID: 31738583 DOI: 10.1080/00365513.2019.1692367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The presence of oxyhaemoglobin and biliverdin interferes with the method recommended by the UK NEQAS Specialist Advisory group for EQA of CSF Proteins and Biochemistry for estimating of the net bilirubin absorbance in CSF. This is easily demonstrated by using solutions with different concentrations of these three substances.The two secondary peaks of the oxyhaemoglobin spectrum at 540 nm and 577 nm are used as reference to minimize these interferences. Those peaks have the same absorbance as at 456 nm in the oxyhaemoglobin spectrum, independent of its concentration. This wavelength is very close to the maximum absorption of bilirubin and, therefore, is suitable for estimating the net bilirubin absorbance.A preliminary study with 48 spectrophotometric analyses of CSF from patients who were suspected of having subarachnoid haemorrhage were used to compare both net bilirubin absorbance estimation methods.The new method is practically free of oxyhaemoglobin and biliverdin interference. This allows for higher sensitivity and a more realistic estimation of the bilirubin concentration in a sample.A better estimation of the bilirubin concentration can have special relevance for diminishing the amount of equivocal or inconclusive cases and also to improve the prematurity of the diagnosis.
Collapse
Affiliation(s)
- Carlos Emilio Rodríguez
- Department of Clinical Chemistry and Transfusion Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
7
|
Comprehensive characterization and resolution of discrepant spectrophotometric bilirubin results in patients on eltrombopag therapy. ACTA ACUST UNITED AC 2019; 58:1713-1723. [DOI: 10.1515/cclm-2019-0684] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Accepted: 08/29/2019] [Indexed: 01/15/2023]
Abstract
Abstract
Background
Eltrombopag is a thrombopoietin receptor agonist used for the treatment of thrombocytopenic conditions. It can cause pH-dependent discoloration of plasma/serum. Eltrombopag is potentially hepatotoxic. It can affect the assessment of hyperbilirubinemia because of its (i) absorbance at ~450 nm (bilirubin), (ii) absorbance at ~550 nm (diazo-bilirubin) and (iii) it can cause yellowish discoloration of the eyes at normal circulating bilirubin levels.
Methods
We collected 66 samples from patients on a range of eltrombopag dosages up to 150 mg daily. Bilirubin was measured using multiple routine spectrophotometric analyzers, the Doumas reference method and high-performance liquid chromatography (HPLC). Plasma/serum eltrombopag concentrations were determined using liquid chromatography tandem mass spectrometry (LC-MS/MS). Spike-in and admixture experiments delineated the effects of eltrombopag and its metabolites.
Results
Forty-nine of 52 samples from patients on ≥50 mg daily eltrombopag therapy showed significantly discrepant inter-analyzer total bilirubin results, a difference up to 64 μmol/L (3.7 mg/dL). In one sample, total bilirubin varied from 8 to 65 μmol/L (0.4–3.8 mg/dL) by different routine analyzers, with direct bilirubin ≤4 μmol/L (0.2 mg/dL). There was a positive correlation between total bilirubin difference and plasma eltrombopag concentration (r = 0.679), and spike-in experiments demonstrated that Beckman AU and Doumas reference methods were susceptible to positive interference. HPLC can quantify bilirubin after separating eltrombopag, and results suggest different analyzers are affected to varying degrees by eltrombopag and its metabolites.
Conclusions
Eltrombopag and its metabolites can cause positive interference to the spectrophotometric measurements of total bilirubin. Accurate measurements of total bilirubin may improve our understanding of the prevalence of hyperbilirubinemia in patients on eltrombopag therapy.
Collapse
|