1
|
Piersanti A, Pacini G, Tura A, D'Argenio DZ, Morettini M. An in-silico modeling approach to separate exogenous and endogenous plasma insulin appearance, with application to inhaled insulin. Sci Rep 2024; 14:10936. [PMID: 38740832 PMCID: PMC11091049 DOI: 10.1038/s41598-024-61293-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 05/03/2024] [Indexed: 05/16/2024] Open
Abstract
The aim of this study was to develop a dynamic model-based approach to separately quantify the exogenous and endogenous contributions to total plasma insulin concentration and to apply it to assess the effects of inhaled-insulin administration on endogenous insulin secretion during a meal test. A three-step dynamic in-silico modeling approach was developed to estimate the two insulin contributions of total plasma insulin in a group of 21 healthy subjects who underwent two equivalent standardized meal tests on separate days, one of which preceded by inhalation of a Technosphere® Insulin dose (22U or 20U). In the 30-120 min test interval, the calculated endogenous insulin component showed a divergence in the time course between the test with and without inhaled insulin. Moreover, the supra-basal area-under-the-curve of endogenous insulin in the test with inhaled insulin was significantly lower than that in the test without (2.1 ± 1.7 × 104 pmol·min/L vs 4.2 ± 1.8 × 104 pmol·min/L, p < 0.01). The percentage of exogenous insulin reaching the plasma, relative to the inhaled dose, was 42 ± 21%. The proposed in-silico approach separates exogenous and endogenous insulin contributions to total plasma insulin, provides individual bioavailability estimates, and can be used to assess the effect of inhaled insulin on endogenous insulin secretion during a meal.
Collapse
Affiliation(s)
- Agnese Piersanti
- Department of Information Engineering, Università Politecnica Delle Marche, Via Brecce Bianche 12, Ancona, Italy
| | | | | | - David Z D'Argenio
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Micaela Morettini
- Department of Information Engineering, Università Politecnica Delle Marche, Via Brecce Bianche 12, Ancona, Italy.
| |
Collapse
|
2
|
Taylor G. The Pharmacokinetics of Inhaled Drugs. J Aerosol Med Pulm Drug Deliv 2023; 36:281-288. [PMID: 37851977 DOI: 10.1089/jamp.2023.29091.gt] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023] Open
Abstract
The pharmacokinetic (PK) profile of a drug after inhalation may differ quite markedly from that seen after dosing by other routes of administration. Drugs may be administered to the lung to elicit a local action or as a portal for systemic delivery of the drug to its site of action elsewhere in the body. Some knowledge of PK is important for both locally- and systemically-acting drugs. For a systemically-acting drug, the plasma concentration-time profile shares some similarities with drug given by the oral or intravenous routes, since the plasma concentrations (after the distribution phase) will be in equilibrium with concentrations at the site of action. For a locally-acting drug, however, the plasma concentrations reflect its fate after it has been absorbed and removed from the airways, and not what is available to its site of action in the lung. Consequently, those typical PK parameters which are determined from plasma concentration measurements, e.g., area under the curve (AUC), Cmax, tmax and post-peak t1/2 may provide information on the deposition and absorption of drugs from the lung; however, the information from these parameters becomes more complicated to decipher for those drugs which are locally-acting in the lung. Additionally, the plasma concentration profile for both locally- and systemically-acting drugs will not only reflect drug absorbed from the lung but also that absorbed from the gastrointestinal (GI) tract from the portion of the dose which is swallowed. This absorption from the GI tract adds a further complication to the interpretation of plasma concentrations, particularly for locally-acting drugs. The influence of physiological and pathological factors needs to be considered in the absorption of some inhaled drugs. The absorption of some hydrophilic drugs is influenced by the inspiratory maneuver used during initial inhalation of the drug, and at later times after deposition. Similarly, the effects of smoking have been shown to increase lung permeability and increase the absorption of certain hydrophilic drugs. The effects of different disease states of the lung have less defined influences on absorption into the systemic circulation.
Collapse
Affiliation(s)
- Glyn Taylor
- School of Pharmacy and Pharmaceutical Sciences, University of Cardiff, United Kingdom
| |
Collapse
|
3
|
Kurtzhals P, Østergaard S, Nishimura E, Kjeldsen T. Derivatization with fatty acids in peptide and protein drug discovery. Nat Rev Drug Discov 2023; 22:59-80. [PMID: 36002588 DOI: 10.1038/s41573-022-00529-w] [Citation(s) in RCA: 30] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/29/2022] [Indexed: 01/28/2023]
Abstract
Peptides and proteins are widely used to treat a range of medical conditions; however, they often have to be injected and their effects are short-lived. These shortcomings of the native structure can be addressed by molecular engineering, but this is a complex undertaking. A molecular engineering technology initially applied to insulin - and which has now been successfully applied to several biopharmaceuticals - entails the derivatization of peptides and proteins with fatty acids. Various protraction mechanisms are enabled by the specific characteristics and positions of the attached fatty acid. Furthermore, the technology can ensure a long half-life following oral administration of peptide drugs, can alter the distribution of peptides and may hold potential for tissue targeting. Due to the inherent safety and well-defined chemical nature of the fatty acids, this technology provides a versatile approach to peptide and protein drug discovery.
Collapse
|
4
|
Levin P, Hoogwerf BJ, Snell-Bergeon J, Vigers T, Pyle L, Bromberger L. Ultra Rapid-Acting Inhaled Insulin Improves Glucose Control in Patients With Type 2 Diabetes Mellitus. Endocr Pract 2020; 27:449-454. [PMID: 33853718 DOI: 10.1016/j.eprac.2020.10.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 09/12/2020] [Accepted: 10/15/2020] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To determine whether the use of an inhaled insulin would improve HbA1c. METHODS This study was performed in 20 type 2 diabetes mellitus (T2DM) participants with HbA1c values ≥7.5 (58) to ≤11.5% (102 mmol/mol) on a variety of glucose-lowering regimens. Prandial Technosphere insulin (TI) was rapidly titrated based on a treatment algorithm using postprandial blood glucose to calculate premeal doses. A 2-week baseline period was followed by 12 weeks of active treatment with TI. The primary outcome was change in HbA1c. Secondary outcomes included glucose time in range (time in range: 70-180 mg/dL) obtained by a blinded continuous glucose monitoring during the baseline period and at the end of 12 weeks. Goals were to assess how to rapidly and safely initiate TI intensification, determine dosing requirements, and establish an effective dose range in uncontrolled T2DM. RESULTS Mean HbA1c decreased by -1.6% (-17 mmol/mol) from 9.0% (75 mmol/mol) at baseline to 7.4% (57 mmol/mol) at 12 weeks (P < .0001). Mean time in range increased from 42.2% to 65.7% (P < .0002). Mean prandial doses of TI were 18 or 19 units for all meals. Time below range was 1.1% baseline and 2.6% post treatment (P = .01). CONCLUSION Treatment with inhaled TI dosed using a simple algorithm improved glycemic control measured by both HbA1c and time in range, with low rates of hypoglycemia. These data add significantly to understanding TI in the management of T2DM patients for whom prandial insulin is a consideration.
Collapse
Affiliation(s)
- Philip Levin
- MODEL Clinical Research, Endocrinology, Baltimore, Maryland.
| | - Byron J Hoogwerf
- Emeritus, Endocrinology, Diabetes and Metabolism, Cleveland Clinic, Cleveland, Ohio; Central Michigan University, Mount Pleasant, Michigan
| | - Janet Snell-Bergeon
- University of Colorado Anschutz Medical Campus, Pediatrics, Aurora, Colorado; Colorado School of Public Health, Department of Biostatistics and Informatics, Aurora, Colorado
| | - Tim Vigers
- University of Colorado Anschutz Medical Campus, Pediatrics, Aurora, Colorado; Colorado School of Public Health, Department of Biostatistics and Informatics, Aurora, Colorado
| | - Laura Pyle
- University of Colorado Anschutz Medical Campus, Pediatrics, Aurora, Colorado; Colorado School of Public Health, Department of Biostatistics and Informatics, Aurora, Colorado
| | - Lee Bromberger
- MODEL Clinical Research, Endocrinology, Baltimore, Maryland
| |
Collapse
|
5
|
Evaluation of pharmacokinetic model designs for subcutaneous infusion of insulin aspart. J Pharmacokinet Pharmacodyn 2017; 44:477-489. [DOI: 10.1007/s10928-017-9535-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 08/11/2017] [Indexed: 10/19/2022]
|
6
|
Rüppel D, Dahmen R, Boss A, Jäger R, Grant M, Baughman R, Klabunde T. A Population Dose-Response Model for Inhaled Technosphere Insulin Administered to Healthy Subjects. CPT-PHARMACOMETRICS & SYSTEMS PHARMACOLOGY 2017; 6:365-372. [PMID: 28568813 PMCID: PMC5488128 DOI: 10.1002/psp4.12189] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Revised: 01/24/2017] [Accepted: 02/16/2017] [Indexed: 11/30/2022]
Abstract
Technosphere insulin (TI), an inhaled insulin with a fast onset of action, provides a novel option for the control of prandial glucose. A euglycemic glucose clamp study was performed to compare the effects of TI and regular human insulin (RHI) on the induced glucose infusion rate (GIR) in healthy volunteers. Generation of a dose–response relationship between insulin dose and effect (expressed as AUC of GIR) was not possible from the clinical data directly. The GIR recording time was too short to capture the full effect and higher doses were not tested. Thus, a pharmacokinetic‐GIR model was developed to simulate GIR for a sufficient time window of 20 h and for higher doses. A dose–response model was then generated from the simulated GIR profiles. The resulting model provides an ED50 for TI that is 5‐fold higher than for RHI, a ratio that can be used as conversion factor for equivalent doses of RHI and TI.
Collapse
Affiliation(s)
- D Rüppel
- Sanofi-Aventis Deutschland GmbH, R&D Frankfurt, Germany
| | - R Dahmen
- Sanofi-Aventis Deutschland GmbH, R&D Frankfurt, Germany
| | - A Boss
- Sanofi US, Bridgewater, New Jersey, USA
| | - R Jäger
- Sanofi-Aventis Deutschland GmbH, R&D Frankfurt, Germany
| | - M Grant
- MannKind Corporation, Danbury, Connecticut, USA
| | - R Baughman
- MannKind Corporation, Danbury, Connecticut, USA
| | - T Klabunde
- Sanofi-Aventis Deutschland GmbH, R&D Frankfurt, Germany
| |
Collapse
|
7
|
Visentin R, Klabunde T, Grant M, Dalla Man C, Cobelli C. Incorporation of inhaled insulin into the FDA accepted University of Virginia/Padova Type 1 Diabetes Simulator. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:3250-3. [PMID: 26736985 DOI: 10.1109/embc.2015.7319085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The University of Virginia/Padova Type 1 Diabetes (T1DM) Simulator has been extensively used in artificial pancreas research mostly for testing and design of control algorithms. However, it also offers the possibility of testing new insulin analogs and alternative routes of delivery given that subcutaneous insulin administration present significant delays & variability. Inhaled insulin appears an important candidate to improve post-prandial glucose control given its rapid appearance in plasma. In this contribution, we present the results of incorporating a pharmacokinetic model of inhaled Technosphere(®) Insulin (TI) into the T1DM simulator. In particular, we successfully reproduced in silico the post-prandial glucose control observed in T1DM subjects treated with TI given at meal time, and the post-prandial glucose dynamics in response to different timing of TI dose.
Collapse
|
8
|
Visentin R, Giegerich C, Jäger R, Dahmen R, Boss A, Grant M, Dalla Man C, Cobelli C, Klabunde T. Improving Efficacy of Inhaled Technosphere Insulin (Afrezza) by Postmeal Dosing: In-silico Clinical Trial with the University of Virginia/Padova Type 1 Diabetes Simulator. Diabetes Technol Ther 2016; 18:574-85. [PMID: 27333446 PMCID: PMC5035370 DOI: 10.1089/dia.2016.0128] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Technosphere(®) insulin (TI), an inhaled human insulin with a fast onset of action, provides a novel option for the control of prandial glucose. We used the University of Virginia (UVA)/Padova simulator to explore in-silico the potential benefit of different dosing regimens on postprandial glucose (PPG) control to support the design of further clinical trials. Tested dosing regimens included at-meal or postmeal dosing, or dosing before and after a meal (split dosing). METHODS Various dosing regimens of TI were compared among one another and to insulin lispro in 100 virtual type-1 patients. Individual doses were identified for each regimen following different titration rules. The resulting postprandial glucose profiles were analyzed to quantify efficacy and the risk for hypoglycemic events. RESULTS This approach allowed us to assess the benefit/risk for each TI dosing regimen and to compare results with simulations of insulin lispro. We identified a new titration rule for TI that could significantly improve the efficacy of treatment with TI. CONCLUSION In-silico clinical trials comparing the treatment effect of different dosing regimens with TI and of insulin lispro suggest that postmeal dosing or split dosing of TI, in combination with an appropriate titration rule, can achieve a superior postprandial glucose control while providing a lower risk for hypoglycemic events than conventional treatment with subcutaneously administered rapid-acting insulin products.
Collapse
Affiliation(s)
- Roberto Visentin
- Department of Information Engineering, University of Padova, Padova, Italy
| | | | - Robert Jäger
- Sanofi-Aventis Deutschland GmbH, Frankfurt, Germany
| | | | | | | | - Chiara Dalla Man
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Claudio Cobelli
- Department of Information Engineering, University of Padova, Padova, Italy
| | | |
Collapse
|
9
|
Weiss M, Tura A, Kautzky-Willer A, Pacini G, D'Argenio DZ. Human insulin dynamics in women: a physiologically based model. Am J Physiol Regul Integr Comp Physiol 2015; 310:R268-74. [PMID: 26608654 DOI: 10.1152/ajpregu.00113.2015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Accepted: 11/20/2015] [Indexed: 11/22/2022]
Abstract
Currently available models of insulin dynamics are mostly based on the classical compartmental structure and, thus, their physiological utility is limited. In this work, we describe the development of a physiologically based model and its application to data from 154 patients who underwent an insulin-modified intravenous glucose tolerance test (IM-IVGTT). To determine the time profile of endogenous insulin delivery without using C-peptide data and to evaluate the transcapillary transport of insulin, the hepatosplanchnic, renal, and peripheral beds were incorporated into the circulatory model as separate subsystems. Physiologically reasonable population mean estimates were obtained for all estimated model parameters, including plasma volume, interstitial volume of the peripheral circulation (mainly skeletal muscle), uptake clearance into the interstitial space, hepatic and renal clearance, as well as total insulin delivery into plasma. The results indicate that, at a population level, the proposed physiologically based model provides a useful description of insulin disposition, which allows for the assessment of muscle insulin uptake.
Collapse
Affiliation(s)
- Michael Weiss
- Department of Pharmacology, Martin Luther University, Halle-Wittenberg, Halle, Germany;
| | - Andrea Tura
- Metabolic Unit, National Research Council Neuroscience Institute, Padova, Italy
| | | | - Giovanni Pacini
- Metabolic Unit, National Research Council Neuroscience Institute, Padova, Italy
| | - David Z D'Argenio
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California
| |
Collapse
|
10
|
Borghardt JM, Weber B, Staab A, Kloft C. Pharmacometric Models for Characterizing the Pharmacokinetics of Orally Inhaled Drugs. AAPS J 2015; 17:853-70. [PMID: 25845315 PMCID: PMC4477002 DOI: 10.1208/s12248-015-9760-6] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Accepted: 03/25/2015] [Indexed: 12/12/2022] Open
Abstract
During the last decades, the importance of modeling and simulation in clinical drug development, with the goal to qualitatively and quantitatively assess and understand mechanisms of pharmacokinetic processes, has strongly increased. However, this increase could not equally be observed for orally inhaled drugs. The objectives of this review are to understand the reasons for this gap and to demonstrate the opportunities that mathematical modeling of pharmacokinetics of orally inhaled drugs offers. To achieve these objectives, this review (i) discusses pulmonary physiological processes and their impact on the pharmacokinetics after drug inhalation, (ii) provides a comprehensive overview of published pharmacokinetic models, (iii) categorizes these models into physiologically based pharmacokinetic (PBPK) and (clinical data-derived) empirical models, (iv) explores both their (mechanistic) plausibility, and (v) addresses critical aspects of different pharmacometric approaches pertinent for drug inhalation. In summary, pulmonary deposition, dissolution, and absorption are highly complex processes and may represent the major challenge for modeling and simulation of PK after oral drug inhalation. Challenges in relating systemic pharmacokinetics with pulmonary efficacy may be another factor contributing to the limited number of existing pharmacokinetic models for orally inhaled drugs. Investigations comprising in vitro experiments, clinical studies, and more sophisticated mathematical approaches are considered to be necessary for elucidating these highly complex pulmonary processes. With this additional knowledge, the PBPK approach might gain additional attractiveness. Currently, (semi-)mechanistic modeling offers an alternative to generate and investigate hypotheses and to more mechanistically understand the pulmonary and systemic pharmacokinetics after oral drug inhalation including the impact of pulmonary diseases.
Collapse
Affiliation(s)
- Jens Markus Borghardt
- />Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Kelchstr. 31, 12169 Berlin, Germany
| | - Benjamin Weber
- />Department of Translational Medicine and Clinical Pharmacology, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Alexander Staab
- />Department of Translational Medicine and Clinical Pharmacology, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Charlotte Kloft
- />Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Kelchstr. 31, 12169 Berlin, Germany
| |
Collapse
|
11
|
Analysis of the absorption kinetics of macromolecules following intradermal and subcutaneous administration. Eur J Pharm Biopharm 2015; 89:134-44. [DOI: 10.1016/j.ejpb.2014.11.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Revised: 11/17/2014] [Accepted: 11/19/2014] [Indexed: 11/23/2022]
|
12
|
Nuffer W, Trujillo JM, Ellis SL. Technosphere insulin (Afrezza): a new, inhaled prandial insulin. Ann Pharmacother 2014; 49:99-106. [PMID: 25313261 DOI: 10.1177/1060028014554648] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE To review the pharmacology, pharmacokinetics, safety, and efficacy of Technosphere insulin (TI), a new inhaled insulin product. DATA SOURCES Searches were conducted in PubMed/MEDLINE, Scientific Citation Index, and abstracts from both the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) meetings from 2005 to August 2014, utilizing the search terms Afrezza, Technosphere, Afresa, and inhaled insulin. References were reviewed to identify additional sources. STUDY SELECTION AND DATA EXTRACTION Studies with adequate sample sizes, evaluating clinically relevant end points were included. DATA SYNTHESIS TI is approved by the Food and Drug Administration as a bolus insulin to treat patients with type 1 and type 2 diabetes. Its glucose-lowering properties are less than that of rapid-acting insulins, but it does demonstrate less hypoglycemia. TI's kinetics make it the fastest absorbed of any insulin available, although its overall onset of action appears similar to insulin lispro. It represents an alternative to bolus injections but would likely be used concomitantly with injected basal insulin. Major adverse effects are respiratory in nature, with cough being the most prominent. There is a small decrease in the forced expiratory volume in 1 s (FEV1) with TI; this appears to be consistent, nonprogressive, and reversible. Patients using TI must receive pulmonary function tests periodically throughout therapy. TI is contraindicated in patients with chronic lung disease and should be used with caution in patients who smoke. CONCLUSION TI is a novel inhaled insulin that provides prandial coverage to patients with diabetes, representing an alternative to bolus insulin injections.
Collapse
Affiliation(s)
- Wesley Nuffer
- University of Colorado Skaggs School of Pharmacy and Pharmaceutical Sciences, Aurora, CO, USA
| | - Jennifer M Trujillo
- University of Colorado Skaggs School of Pharmacy and Pharmaceutical Sciences, Aurora, CO, USA
| | - Samuel L Ellis
- University of Colorado Skaggs School of Pharmacy and Pharmaceutical Sciences, Aurora, CO, USA
| |
Collapse
|
13
|
Kagan L. Pharmacokinetic Modeling of the Subcutaneous Absorption of Therapeutic Proteins. Drug Metab Dispos 2014; 42:1890-905. [DOI: 10.1124/dmd.114.059121] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
|
14
|
de la Peña A, Ma X, Reddy S, Ovalle F, Bergenstal RM, Jackson JA. Application of PK/PD modeling and simulation to dosing regimen optimization of high-dose human regular U-500 insulin. J Diabetes Sci Technol 2014; 8:821-9. [PMID: 24876428 PMCID: PMC4764242 DOI: 10.1177/1932296814532326] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Pharmacokinetic/pharmacodynamic (PK/PD) studies of human regular U-500 insulin (U-500R) at high doses commonly used in clinical practice (>100 units) have not been performed. The current analysis applied PK/PD modeling/simulation to fit the data and simulate single-dose and steady-state PK/PD of U-500R high-dose regimens. Data from 3 single-dose euglycemic clamp studies in healthy obese and normal-weight patients, and normal-weight patients with type 1 diabetes were used to build the model. The model was sequential (PK inputs fed into PD component). PK was described using a 1-compartment model with first-order absorption and elimination. The model estimated separate absorption rate constants for U-500R and human regular U-100 insulin. The PD component used an effect compartment model, parameterized in terms of maximum pharmacologic effect (E(max)) and concentration to achieve 50% of E(max). The model described the data well. Steady-state PK for once-daily (QD), twice-daily (BID), or thrice-daily (TID) administration appeared to be reached 24 hours after the first dose. At steady-state, QD dosing showed the greatest fluctuations in PK/PD. BID dosing showed a gradual increase in insulin action with each dose and a fairly stable basal insulin effect. For TID dosing, activity was maintained throughout the dosing interval. PK/PD modeling/simulation of high U-500R doses supports BID or TID administration with an extended duration of activity relative to QD. TID dosing may provide slightly better full-day insulin effect. Additional PK/PD studies and randomized controlled trials of U-500R are needed to validate model predictions in patients with insulin-resistant diabetes requiring high-dose insulin.
Collapse
Affiliation(s)
| | - Xiaosu Ma
- Eli Lilly and Company, Indianapolis, IN, USA
| | | | - Fernando Ovalle
- UAB Comprehensive Diabetes Center, Division of Endocrinology, Diabetes & Metabolism, University of Alabama at Birmingham School of Medicine, Birmingham, AL, USA
| | | | | |
Collapse
|
15
|
Bartels C, Looby M, Sechaud R, Kaiser G. Determination of the pharmacokinetics of glycopyrronium in the lung using a population pharmacokinetic modelling approach. Br J Clin Pharmacol 2013; 76:868-79. [PMID: 23506208 PMCID: PMC3845310 DOI: 10.1111/bcp.12118] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Accepted: 03/10/2013] [Indexed: 11/27/2022] Open
Abstract
AIMS Glycopyrronium bromide (NVA237) is a once-daily long-acting muscarinic antagonist recently approved for the treatment of chronic obstructive pulmonary disease. In this study, we used population pharmacokinetic (PK) modelling to provide insights into the impact of the lung PK of glycopyrronium on its systemic PK profile and, in turn, to understand the impact of lung bioavailability and residence time on the choice of dosage regimen. METHODS We developed and validated a population PK model to characterize the lung absorption of glycopyrronium using plasma PK data derived from studies in which this drug was administered by different routes to healthy volunteers. The model was also used to carry out simulations of once-daily and twice-daily regimens and to characterize amounts of glycopyrronium in systemic compartments and lungs. RESULTS The model-derived PK parameters were comparable to those obtained with noncompartmental analysis, confirming the usefulness of our model. The model suggested that the lung absorption of glycopyrronium was dominated by slow-phase absorption with a half-life of about 3.5 days, which accounted for 79% of drug absorbed through the lungs into the bloodstream, from where glycopyrronium was quickly eliminated. Simulations of once-daily and twice-daily administration generated similar PK profiles in the lung compartments. CONCLUSIONS The slow absorption from the lungs, together with the rapid elimination from the systemic circulation, could explain how once-daily glycopyrronium provides sustained bronchodilatation with a low incidence of adverse effects in patients with chronic obstructive pulmonary disease. Its extended intrapulmonary residence time also provides pharmacokinetic evidence that glycopyrronium has the profile of a once-daily drug.
Collapse
Affiliation(s)
| | | | - Romain Sechaud
- Novartis Institutes for Biomedical ResearchBasel, Switzerland
| | - Guenther Kaiser
- Novartis Institutes for Biomedical ResearchBasel, Switzerland
| |
Collapse
|
16
|
Haidar A, Duval C, Legault L, Rabasa-Lhoret R. Pharmacokinetics of insulin aspart and glucagon in type 1 diabetes during closed-loop operation. J Diabetes Sci Technol 2013; 7:1507-12. [PMID: 24351176 PMCID: PMC3876328 DOI: 10.1177/193229681300700610] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND We assessed the pharmacokinetics of subcutaneous insulin aspart and glucagon during closed-loop operation and their relationship with body composition variables. METHODS We retrospectively analyzed data collected from closed-loop experiments in 15 type 1 diabetes patients (age 47.1 ± 12.3 years, body mass index 25.9 ± 4.6 kg/m², glycated hemoglobin 7.9% ± 0.7%). Patients received an evening meal accompanied with prandial insulin bolus and stayed in the clinical facility until the next morning. Glucose levels were regulated by dual-hormone closed-loop delivery. Insulin and glucagon were delivered using two subcutaneous infusion pumps installed on the abdominal wall. Plasma insulin and glucagon were measured every 10-30 min. Percentage of body fat, percentage of fat in the abdominal area, and mass of abdominal fat were measured by dual X-ray absorptiometry. RESULTS A pharmacokinetic model estimated time-to-peak plasma concentrations [t(max) insulin 51 (19) min, t(max) glucagon 19 (4) min, mean (standard deviation)], metabolic clearance rate [MCR insulin 0.019 (0.015-0.026) liter/kg/min, MCR glucagon 0.012 (0.010-0.014) liter/kg/min, median (interquartile range)], and the background plasma concentrations [I(b) insulin 10.2 (6.3-15.2) mU/liter, I(b) glucagon 50 (45-56) pg/ml, median (interquartile range)]. t(max) correlated positively between insulin and glucagon (r = 0.7; p = .007) while MCR correlated negatively (r = -0.7; p = .015). In this small sample size, t(max), MCR, and I(b) of insulin and glucagon did not correlate with percentage of body fat, percentage of fat in the abdominal area, or total mass of abdominal fat. CONCLUSIONS Insulin and glucagon pharmacokinetics might be related during closed-loop operation. Our data suggest that slower absorption of insulin is associated with slower absorption of glucagon. Body composition does not seem to influence insulin and glucagon pharmacokinetics.
Collapse
Affiliation(s)
- Ahmad Haidar
- Institut de Recherches Cliniques de Montréal 110, avenue des Pins Ouest, Montréal, Québec, Canada H2W 1R7.
| | | | | | | |
Collapse
|
17
|
Zarogoulidis P, Petridis D, Ritzoulis C, Li Q, Huang H, Ning Y, Darwiche K, Freitag L, Zarogoulidis K. Further experimentation of inhaled; LANTUS, ACTRAPID and HUMULIN with todays' production systems. Int J Pharm 2013; 458:39-47. [PMID: 24140545 DOI: 10.1016/j.ijpharm.2013.10.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Revised: 09/30/2013] [Accepted: 10/02/2013] [Indexed: 12/22/2022]
Abstract
BACKGROUND Several aerosol production systems have been used for aerosol insulin production. However; since the first studies several new models of jet-nebulizers and ultrasound nebulizers have been introduced in the market. MATERIALS AND METHODS Three different models of jet-nebulizers (different brands, same properties) and three different ultrasound nebulizers (different brands, same properties). Six residual cups (2 small ≤ 6 ml and 3 large ≤ 8 ml) were used for the jet-nebulizers. The ultrasound nebulizers were used with their facemasks or with their inlets which were included in the purchase package. RESULTS Ultrasound nebulizers; LANTUS produces by far the lowest mean droplets (2.44) half the size of the other two drugs (4.43=4.97). GIMA nebulizer is the most efficient producing one third of the droplet size of SHIMED and one second of EASYNEB (2.06<3.15<6.62). Finally, the 4 ml loading concentration is more suitable for supporting the production of smaller droplets (3.65<4.24). Drugs and nebulizers act interactively yielding very large droplets when ACTRAPID and HUMULIN are administered in joint with SHIMED nebulizer (9.59=7.72). Jet-nebulizers; HUMULIN again is the least preferred insulin since it hardly reaches the low but equal performance of others at the loading level of 6 ml. Residual cups E and B produce uniquely lower mean droplets at loading level 6. CONCLUSIONS Ultrasound nebulizers; the best suggested combination should be LANTUS insulin, GIMA nebulizer administered at loading dose of 4 ml jet-nebulizers. A global review can give the best combination: the lowest mean droplets are produced when the drugs LANTUS (mostly) and ACTRAPID are administered, applying the SUNMIST nebulizer in concert with residual cup B at loading levels of 6 ml.
Collapse
Affiliation(s)
- Paul Zarogoulidis
- Pulmonary Department, "G. Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece; Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Hong Y, Dingemanse J, Sidharta P, Mager DE. Population pharmacodynamic modeling of hyperglycemic clamp and meal tolerance tests in patients with type 2 diabetes mellitus. AAPS JOURNAL 2013; 15:1051-63. [PMID: 23904152 DOI: 10.1208/s12248-013-9512-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Accepted: 07/08/2013] [Indexed: 11/30/2022]
Abstract
In this study, glucose and insulin concentration-time profiles in subjects with type 2 diabetes mellitus (T2DM) under meal tolerance test (MTT) and hyperglycemic clamp (HGC) conditions were co-modeled simultaneously. Blood glucose and insulin concentrations were obtained from 20 subjects enrolled in a double-blind, placebo-controlled, randomized, two-way crossover study. Patients were treated with palosuran or placebo twice daily for 4 weeks and then switched to the alternative treatment after a 4-week washout period. The MTT and HGC tests were performed 1 h after drug administration on days 28 and 29 of each treatment period. Population data analysis was performed using NONMEM. The HGC model incorporates insulin-dependent glucose clearance and glucose-induced insulin secretion. This model was extended for the MTT, in which glucose absorption was described using a transit compartment with a mean transit time of 62.5 min. The incretin effect (insulin secretion triggered by oral glucose intake) was also included, but palosuran did not influence insulin secretion or sensitivity. Glucose clearance was 0.164 L/min with intersubject and interoccasion variability of 9.57% and 31.8%. Insulin-dependent glucose clearance for the HGC was about 3-fold greater than for the MTT (0.0111 vs. 0.00425 L/min/[mU/L]). The maximal incretin effect was estimated to enhance insulin secretion 2-fold. The lack of palosuran effect coupled with a population-based analysis provided quantitative insights into the variability of glucose and insulin regulation in patients with T2DM following multiple glucose tolerance tests. Application of these models may also prove useful in antihyperglycemic drug development and assessing glucose-insulin homeostasis.
Collapse
Affiliation(s)
- Ying Hong
- Department of Pharmaceutical Sciences, University at Buffalo, SUNY, 431 Kapoor Hall, Buffalo, New York, 14214, USA
| | | | | | | |
Collapse
|
19
|
Ramchandani N, Heptulla RA. New technologies for diabetes: a review of the present and the future. INTERNATIONAL JOURNAL OF PEDIATRIC ENDOCRINOLOGY 2012; 2012:28. [PMID: 23098076 PMCID: PMC3541087 DOI: 10.1186/1687-9856-2012-28] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Accepted: 10/15/2012] [Indexed: 11/10/2022]
Abstract
This review summarizes the technologies in use and in the pipeline for the management of diabetes. The review focuses on glucose meters, continuous glucose monitoring devices, insulin pumps, and getting clinicians connected to technologies. All information presented can be found in the public domain, and was obtained from journal articles, websites, product review tables in patient publications, and professional conferences. The technology concerns, ongoing development and future trends in this area are also discussed.
Collapse
Affiliation(s)
- Neesha Ramchandani
- The Children's Hospital at Montefiore, Division of Pediatric Endocrinology & Diabetes, 3415 Bainbridge Ave, Bronx, NY, 10467, USA.
| | | |
Collapse
|
20
|
Abstract
INTRODUCTION Insulin has usually been administered subcutaneously in the treatment of diabetes mellitus. Alternative delivery routes of insulin are expected to overcome some limitations, mainly concerned with the possibility of hypoglycemia episodes, weight gain and inadequate post-meal glucose control, in order to lead a better patient compliance. AREAS COVERED This review article covers all the most relevant non-invasive insulin delivery methods under development, respective technology and clinical data available according to their status of development. Special focus is given to the systems with late clinical trial evidences, their achievements and pitfalls. Pulmonary and oral appear to be the most advantageous routes, with regard to the long list of potentially marketed products. EXPERT OPINION Alternative insulin delivery to the subcutaneous administration is more and more close to the success, being fundamental that any optimized technology could overcome the overall low mucosal bioavailability of insulin, mostly due to its early degradation before absorption, inactivation and digestion by proteolytic enzymes and poor permeability across mucosal epithelium because of its high molecular weight and lack of lipophilicity.
Collapse
Affiliation(s)
- Sandra Soares
- CICS, Department of Pharmaceutical Sciences, Instituto Superior de Ciências da Saúde-Norte, CESPU, Gandra, Portugal
| | | | | |
Collapse
|
21
|
Flip-flop pharmacokinetics--delivering a reversal of disposition: challenges and opportunities during drug development. Ther Deliv 2012; 2:643-72. [PMID: 21837267 DOI: 10.4155/tde.11.19] [Citation(s) in RCA: 176] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Flip-flop pharmacokinetics is a phenomenon often encountered with extravascularly administered drugs. Occurrence of flip-flop spans preclinical to human studies. The purpose of this article is to analyze both the pharmacokinetic interpretation errors and opportunities underlying the presence of flip-flop pharmacokinetics during drug development. Flip-flop occurs when the rate of absorption is slower than the rate of elimination. If it is not recognized, it can create difficulties in the acquisition and interpretation of pharmacokinetic parameters. When flip-flop is expected or discovered, a longer duration of sampling may be necessary in order to avoid overestimation of fraction of dose absorbed. Common culprits of flip-flop disposition are modified dosage formulations; however, formulation characteristics such as the drug chemical entities themselves or the incorporated excipients can also cause the phenomenon. Yet another contributing factor is the physiological makeup of the extravascular site of administration. In this article, these causes of flip-flop pharmacokinetics are discussed with incorporation of relevant examples and the implications for drug development outlined.
Collapse
|
22
|
|
23
|
Abstract
Recombinant therapeutic protein drugs have now been in clinical use for nearly three decades and have advanced considerably in complexity over this time period. Regulatory approvals of some early pioneering protein drugs did not require characterization of metabolism, but more recently regulatory expectations and guidance have appropriately evolved. Sponsors may now be expected to investigate metabolism of newer biologics as the structural complexity of proteins has increased markedly, particularly with the introduction of conjugated and modified proteins. This review discusses the value and need for metabolite characterization of some therapeutic proteins by presenting select examples. Regulatory expectations will undoubtedly evolve further with the development of other novel macromolecular biologic therapeutics based on modified nucleic acids, novel conjugated lipids and polysaccharides.
Collapse
|