1
|
Berg KA, DeFreese AJ, Sisler-Dinwiddie AL, Labadie RF, Tawfik KO, Gifford RH. Clinical Applications for Spread of Excitation Functions Obtained Via Electrically Evoked Compound Action Potentials (eCAP). Otol Neurotol 2024; 45:790-797. [PMID: 38923968 DOI: 10.1097/mao.0000000000004242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
OBJECTIVES To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample. STUDY DESIGN Retrospective case review. SETTING Cochlear implant (CI) program at a tertiary medical center. PATIENTS Two hundred seventy-two ears (238 patients) with Cochlear Ltd. CIs (mean age = 46 yr, range = 9 mo-93 yr, 50% female) implanted between August 2014 and December 2022 were included. MAIN OUTCOME MEASURES eCAP SOE widths (mm) (probe electrodes 5, 11, and 17), incidence of electrode tip fold-over, CT imaging data (electrode-to-modiolus distance, angular insertion depth, scalar location), and speech recognition outcomes (consonant-nucleus-consonant [CNC], AzBio quiet, and +5 dB SNR) through the first year after CI activation. RESULTS 1) eCAP SOE demonstrated a sensitivity of 85.7% for identifying tip fold-over instances that were confirmed by CT imaging. In the current dataset, the tip fold-over incidence rate was 3.1% (7 patients), with all instances involving a precurved electrode array. 2) There was a significant positive relationship between eCAP SOE and mean electrode-to-modiolus distance for precurved arrays, and a significant positive relationship between eCAP SOE and angular insertion depth for straight arrays. No relationships between eCAP SOE and scalar location or cochlea diameter were found in this sample. 3) There were no significant relationships between eCAP SOE and speech recognition outcomes for any measure or time point, except for a weak negative correlation between average eCAP SOE widths and CNC word scores at 6 months post-activation for precurved arrays. CONCLUSIONS In the absence of intraoperative CT or fluoroscopic imaging, eCAP SOE is a reasonable alternative method for identifying electrode array tip fold-over and should be routinely measured intraoperatively, especially for precurved electrode arrays with a sheath.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Andrea J DeFreese
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | | | - Robert F Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | | | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
2
|
Micuda A, Li H, Rask-Andersen H, Ladak HM, Agrawal SK. Morphologic Analysis of the Scala Tympani Using Synchrotron: Implications for Cochlear Implantation. Laryngoscope 2024; 134:2889-2897. [PMID: 38189807 DOI: 10.1002/lary.31263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 12/04/2023] [Accepted: 12/20/2023] [Indexed: 01/09/2024]
Abstract
OBJECTIVES To use synchrotron radiation phase-contrast imaging (SR-PCI) to visualize and measure the morphology of the entire cochlear scala tympani (ST) and assess cochlear implant (CI) electrode trajectories. METHODS SR-PCI images were used to obtain geometric measurements of the cochlear scalar diameter and area at 5-degree increments in 35 unimplanted and three implanted fixed human cadaveric cochleae. RESULTS The cross-sectional diameter and area of the cochlea were found to decrease from the base to the apex. This study represents a wide variability in cochlear morphology and suggests that even in the smallest cochlea, the ST can accommodate a 0.4 mm diameter electrode up to 720°. Additionally, all lateral wall array trajectories were within the anatomically accommodating insertion zone. CONCLUSION This is the first study to use SR-PCI to visualize and quantify the entire ST morphology, from the round window to the apical tip, and assess the post-operative trajectory of electrodes. These high-resolution anatomical measurements can be used to inform the angular insertion depth that can be accommodated in CI patients, accounting for anatomical variability. LEVEL OF EVIDENCE N/A. Laryngoscope, 134:2889-2897, 2024.
Collapse
Affiliation(s)
- Ashley Micuda
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Hao Li
- Department of Surgical Sciences, Otorhinolaryngology and Head and Neck Surgery, Uppsala University, Uppsala, Sweden
| | - Helge Rask-Andersen
- Department of Surgical Sciences, Otorhinolaryngology and Head and Neck Surgery, Uppsala University, Uppsala, Sweden
| | - Hanif M Ladak
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Western University, London, Ontario, Canada
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Ontario, Canada
- Department of Electrical and Computer Engineering, Western University, London, Ontario, Canada
| | - Sumit K Agrawal
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Western University, London, Ontario, Canada
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Ontario, Canada
- Department of Electrical and Computer Engineering, Western University, London, Ontario, Canada
| |
Collapse
|
3
|
Vohra V, Andresen NS, Carver C, Dunham R, Marsiglia D, Yeagle J, Della Santina CC, Creighton FX, Bowditch SP, Sun DQ. Cochlear Implant Electrode Array Design and Speech Understanding. Otol Neurotol 2024; 45:136-142. [PMID: 38152035 DOI: 10.1097/mao.0000000000004083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2023]
Abstract
OBJECTIVE Cochlear implant electrode arrays are categorized based on their design as lateral wall (LW) and perimodiolar (PM) electrode arrays. The objective of this study was to investigate the effect of LW versus PM designs on postoperative speech perception across multiple manufacturers and over long follow-up durations. DESIGN Retrospective cohort study. SETTING Single academic medical center. PARTICIPANTS A total of 478 adult cochlear implant recipients, implanted between the years 1992 and 2017. INTERVENTIONSS PM versus LW cochlear implants. MAIN OUTCOMES AND MEASURES Postoperative Consonant-Nucleus-Consonant Word (CNC-w) and Hearing in Noise Test (HINT) scores between 6 months and 5 years. RESULTS Across 478 patients, approximately one-third received LW (n = 176, 36.8%), whereas 302 patients received a PM array (63.2%). The PM group had higher CNC-w scores from 6 months to 2 years (52 [interquartile range, 38-68] versus 48 [31-62], p = 0.036) and from 2 to 5 years (58 [43-72] versus 48 [33-66], p < 0.001). Multivariable analysis of patient-averaged scores indicated that the PM group had greater improvement from preoperative scores at all time points after the initial 6 months for both CNC-w ( β = 4.4 [95% confidence interval, 0.6-8.3], p = 0.023) and HINT testing ( β = 4.5 [95% confidence interval, 0.3-8.7], p = 0.038). CONCLUSIONS This study indicates that PM electrode arrays are associated with small increases in postoperative speech perception scores, relative to LW arrays, when assessed across manufacturers, over long time durations, and using multiple outcome instruments. These findings may help guide surgeon selection and patient counseling of cochlear implant arrays.
Collapse
Affiliation(s)
| | - Nicholas S Andresen
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Courtney Carver
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Rachel Dunham
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Dawn Marsiglia
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Jenifer Yeagle
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Charles C Della Santina
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Francis X Creighton
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Stephen P Bowditch
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Daniel Q Sun
- Department of Otolaryngology-Head and Neck Surgery and Cochlear Implant Center, Johns Hopkins University School of Medicine, Baltimore, Maryland
| |
Collapse
|
4
|
Smetak MR, Fernando SJ, O'Malley MR, Bennett ML, Haynes DS, Wootten CT, Virgin FW, Dwyer RT, Dawant BM, Noble JH, Labadie RF. Electrode array positioning after cochlear reimplantation from single manufacturer. Cochlear Implants Int 2023; 24:273-281. [PMID: 37489512 PMCID: PMC10372339 DOI: 10.1080/14670100.2023.2179756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
OBJECTIVE To investigate whether revision surgery with the same device results in a change in three key indicators of electrode positioning: scalar location, mean modiolar distance (M ¯ ), and angular insertion depth (AID). METHODS Retrospective analysis of a cochlear implant database at a university-based tertiary medical center. Intra-operative CT scans were obtained after initial and revision implantation. Electrode array (EA) position was calculated using auto-segmentation techniques. Initial and revision scalar location, M ¯ , and AID were compared. RESULTS Mean change in M ¯ for all ears was -0.07 mm (SD 0.24 mm; P = 0.16). The mean change in AID for all ears was -5° (SD 67°; P = 0.72). Three initial implantations with pre-curved EAs resulted in a translocation from Scala Tympani (ST) to Scala Vestibuli (SV). Two remained translocated after revision, while one was corrected when revised with a straight EA. An additional five translocations occurred after revision. CONCLUSIONS In this study examining revision cochlear implantation from a single manufacturer, we demonstrated no significant change in key indicators of EA positioning, even when revising with a different style of electrode. However, the revision EA is not necessarily confined by the initial trajectory and there may be an increased risk of translocation.
Collapse
Affiliation(s)
- Miriam R Smetak
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Shanik J Fernando
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Matthew R O'Malley
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Marc L Bennett
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - David S Haynes
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Christopher T Wootten
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Frank W Virgin
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN 37232, USA
| | - Benoit M Dawant
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, TN 37235, USA
| | - Jack H Noble
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, TN 37235, USA
| | - Robert F Labadie
- Department of Otolaryngology - Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge 135 Rutledge Avenue, MSC 550, Charleston, SC 29425, USA
| |
Collapse
|
5
|
Fujiwara RJ, Ishiyama G, Lopez IA, Ishiyama A. Morphometric Analysis and Linear Measurements of the Scala Tympani and Implications in Cochlear Implant Electrodes. Otol Neurotol 2023; 44:e343-e349. [PMID: 36893208 PMCID: PMC10175138 DOI: 10.1097/mao.0000000000003848] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/10/2023]
Abstract
HYPOTHESIS The objective of this study was to perform detailed height and cross-sectional area measurements of the scala tympani in histologic sections of nondiseased human temporal bones and correlate them with cochlear implant electrode dimensions. BACKGROUND Previous investigations in scala tympani dimensions have used microcomputed tomography or casting modalities, which cannot be correlated directly with microanatomy visible on histologic specimens. METHODS Three-dimensional reconstructions of 10 archival human temporal bone specimens with no history of middle or inner ear disease were generated using hematoxylin and eosin histopathologic slides. At 90-degree intervals, the heights of the scala tympani at lateral wall, midscala, and perimodiolar locations were measured, along with cross-sectional area. RESULTS The vertical height of the scala tympani at its lateral wall significantly decreased from 1.28 to 0.88 mm from 0 to 180 degrees, and the perimodiolar height decreased from 1.20 to 0.85 mm. The cross-sectional area decreased from 2.29 (standard deviation, 0.60) mm 2 to 1.38 (standard deviation, 0.13) mm 2 from 0 to 180 degrees ( p = 0.001). After 360 degrees, the scala tympani shape transitioned from an ovoid to triangular shape, corresponding with a significantly decreased lateral height relative to perimodiolar height. Wide variability was observed among the cochlear implant electrode sizes relative to scala tympani measurements. CONCLUSION The present study is the first to conduct detailed measurements of heights and cross-sectional area of the scala tympani and the first to statistically characterize the change in its shape after the basal turn. These measurements have important implications in understanding locations of intracochlear trauma during insertion and electrode design.
Collapse
Affiliation(s)
- Rance J.T. Fujiwara
- David Geffen School of Medicine at UCLA, Department of Head and Neck Surgery, Los Angeles 90095
| | - Gail Ishiyama
- David Geffen School of Medicine at UCLA, Department of Neurology, Los Angeles 90095
| | - Ivan A. Lopez
- David Geffen School of Medicine at UCLA, Department of Head and Neck Surgery, Los Angeles 90095
| | - Akira Ishiyama
- David Geffen School of Medicine at UCLA, Department of Head and Neck Surgery, Los Angeles 90095
| |
Collapse
|
6
|
Thomas JP, Klein H, Haubitz I, Dazert S, Völter C. Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection. J Pers Med 2023; 13:jpm13040633. [PMID: 37109019 PMCID: PMC10142378 DOI: 10.3390/jpm13040633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 03/25/2023] [Accepted: 03/30/2023] [Indexed: 04/09/2023] Open
Abstract
Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection.
Collapse
Affiliation(s)
- Jan Peter Thomas
- Department of Otorhinolaryngology, Head and Neck Surgery, St. Johannes Hospital, Cath. St. Paulus Society, Academic Teaching Hospital of the University of Münster, Johannesstr. 9-17, 44137 Dortmund, Germany
| | - Hannah Klein
- Department of Otorhinolaryngology, Head and Neck Surgery, Katholisches Klinikum, Ruhr University Bochum, Bleichstr. 15, 44787 Bochum, Germany
| | - Imme Haubitz
- Department of Otorhinolaryngology, Head and Neck Surgery, Katholisches Klinikum, Ruhr University Bochum, Bleichstr. 15, 44787 Bochum, Germany
| | - Stefan Dazert
- Department of Otorhinolaryngology, Head and Neck Surgery, Katholisches Klinikum, Ruhr University Bochum, Bleichstr. 15, 44787 Bochum, Germany
| | - Christiane Völter
- Department of Otorhinolaryngology, Head and Neck Surgery, Katholisches Klinikum, Ruhr University Bochum, Bleichstr. 15, 44787 Bochum, Germany
| |
Collapse
|
7
|
Munhall CC, Noble JH, Dawant B, Labadie RF. Cochlear Implant Translocation: Diagnosis, Prevention, and Clinical Implications. CURRENT OTORHINOLARYNGOLOGY REPORTS 2022. [DOI: 10.1007/s40136-022-00434-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
8
|
Weber L, Kwok P, Picou EM, Wendl C, Bohr C, Marcrum SC. [Measuring the cochlea using a tablet-based software package: influence of imaging modality and rater background]. HNO 2022; 70:769-777. [PMID: 35970933 PMCID: PMC9512738 DOI: 10.1007/s00106-022-01208-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/20/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND Cochlear duct length (CDL) is subject to significant individual variation. In the context of cochlear implantation, adapting the electrode array length to the CDL is of potential interest, as it has been associated with improvements in both speech recognition and sound quality. Using a tablet-based software package, it is possible to measure CDL at the level of the organ of Corti (CDLOC) to select appropriate electrode array lengths based on individual cochlear anatomy. OBJECTIVE To identify effects of imaging modality and rater background on CDL estimates. METHODS Magnetic resonance imaging (MRI) and flat-panel volume CT (fpVCT) scans of 10 patients (20 cochleae) were analyzed using the OTOPLAN software package (MED-EL, Innsbruck, Austria). Raters were an otorhinolaryngology (ORL) specialist, an ORL resident, and an audiologist. To analyze effects of rater background and imaging modality on CDL measurements, linear mixed models were constructed. RESULTS Measurements showed mean CDLOC(fpVCT) = 36.69 ± 1.78 mm and CDLOC(MRI) = 36.81 ± 1.87 mm. Analyses indicated no significant effect of rater background (F(2, 105) = 0.84; p = 0.437) on CDL estimates. Imaging modality, on the other hand, significantly affected CDL (F (1, 105) = 20.70; p < 0.001), whereby estimates obtained using MRI were 0.89 mm larger than those obtained using fpVCT. CONCLUSION No effect of rater background on CDL estimates could be identified, suggesting that comparable measurements could be obtained by personnel other than specially trained neurootologists. While imaging modality (fpVCT vs. MRI) did impact CDL results, the difference was small and of questionable clinical significance.
Collapse
Affiliation(s)
- Lena Weber
- Klinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde, Universitätsklinikum Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Deutschland.
| | - Pingling Kwok
- Klinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde, Universitätsklinikum Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Deutschland
| | - Erin M Picou
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 2201 West End Avenue, Nashville, TN 37235, USA
| | - Christina Wendl
- Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, Franz-Josef-Strauß Allee 11, 93053, Regensburg, Deutschland
| | - Christopher Bohr
- Klinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde, Universitätsklinikum Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Deutschland
| | - Steven C Marcrum
- Klinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde, Universitätsklinikum Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Deutschland
| |
Collapse
|
9
|
Computed-Tomography Estimates of Interaural Mismatch in Insertion Depth and Scalar Location in Bilateral Cochlear-Implant Users. Otol Neurotol 2022; 43:666-675. [PMID: 35761459 DOI: 10.1097/mao.0000000000003538] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
HYPOTHESIS Bilateral cochlear-implant (BI-CI) users will have a range of interaural insertion-depth mismatch because of different array placement or characteristics. Mismatch will be larger for electrodes located near the apex or outside scala tympani, or for arrays that are a mix of precurved and straight types. BACKGROUND Brainstem superior olivary-complex neurons are exquisitely sensitive to interaural-difference cues for sound localization. Because these neurons rely on interaurally place-of-stimulation-matched inputs, interaural insertion-depth or scalar-location differences for BI-CI users could cause interaural place-of-stimulation mismatch that impairs binaural abilities. METHODS Insertion depths and scalar locations were calculated from temporal-bone computed-tomography scans for 107 BI-CI users (27 Advanced Bionics, 62 Cochlear, 18 MED-EL). RESULTS Median interaural insertion-depth mismatch was 23.4 degrees or 1.3 mm. Mismatch in the estimated clinically relevant range expected to impair binaural processing (>75 degrees or 3 mm) occurred for 13 to 19% of electrode pairs overall, and for at least three electrode pairs for 23 to 37% of subjects. There was a significant three-way interaction between insertion depth, scalar location, and array type. Interaural insertion-depth mismatch was largest for apical electrodes, for electrode pairs in two different scala, and for arrays that were both-precurved. CONCLUSION Average BI-CI interaural insertion-depth mismatch was small; however, large interaural insertion-depth mismatch-with the potential to degrade spatial hearing-occurred frequently enough to warrant attention. For new BICI users, improved surgical techniques to avoid interaural insertion-depth and scalar mismatch are recommended. For existing BI-CI users with interaural insertion-depth mismatch, interaural alignment of clinical frequency tables might reduce negative spatial-hearing consequences.
Collapse
|
10
|
Van de Heyning P, Roland P, Lassaletta L, Agrawal S, Atlas M, Baumgartner WD, Brown K, Caversaccio M, Dazert S, Gstoettner W, Hagen R, Hagr A, Jablonski GE, Kameswaran M, Kuzovkov V, Leinung M, Li Y, Loth A, Magele A, Mlynski R, Mueller J, Parnes L, Radeloff A, Raine C, Rajan G, Schmutzhard J, Skarzynski H, Skarzynski PH, Sprinzl G, Staecker H, Stöver T, Tavora-Viera D, Topsakal V, Usami SI, Van Rompaey V, Weiss NM, Wimmer W, Zernotti M, Gavilan J. Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events. Front Surg 2022; 9:823219. [PMID: 35402479 PMCID: PMC8987358 DOI: 10.3389/fsurg.2022.823219] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/09/2022] [Indexed: 12/05/2022] Open
Abstract
Background and Objective The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. Methods A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. Results A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4-6.6%) of ETFO, 28.6% (26.6-30.6%) of ESD, and 0.53% (0.2-1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1-1.3%), 11% (9.2-13.0%), and 3.2% (2.5-3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. Conclusion Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications.
Collapse
Affiliation(s)
- Paul Van de Heyning
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Peter Roland
- Department of Otolaryngology, Head & Neck Surgery, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Luis Lassaletta
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| | - Sumit Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Marcus Atlas
- Ear Sciences Institute Australia, Lions Hearing Clinic, Perth, WA, Australia
| | | | - Kevin Brown
- UNC Ear and Hearing Center at Chapel Hill School of Medicine, Chapel Hill, NC, United States
| | - Marco Caversaccio
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | | | - Rudolf Hagen
- Würzburg ENT University Hospital, Würzburg, Germany
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Greg Eigner Jablonski
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Otorhinolaryngology & Head and Neck Surgery, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| | | | - Vladislav Kuzovkov
- St. Petersburg ENT and Speech Research Institute, St. Petersburg, Russia
| | - Martin Leinung
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Yongxin Li
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Key Laboratory of Otolaryngology Head and Neck Surgery (Capital Medical University), Ministry of Education, Beijing, China
| | - Andreas Loth
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Astrid Magele
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner” Rostock University Medical Center, Rostock, Germany
| | - Joachim Mueller
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Ludwig-Maximilians-Universitat Munchen, Munchen, Germany
| | - Lorne Parnes
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Andreas Radeloff
- Division of Oto-Rhino-Laryngology, Evangelisches Krankenhaus Oldenburg, Research Center of Neurosensory Sciences, University Oldenburg, Oldenburg, Germany
| | - Chris Raine
- Bradford Royal Infirmary Yorkshire Auditory Implant Center, Bradford, United Kingdom
| | - Gunesh Rajan
- Department of Otolaryngology, Head and Neck Surgery, Luzerner Kantonsspital, Luzern, Medical Sciences Department of Health Sciences and Medicine. University of Lucerne, Luzern, Switzerland. Otolaryngology, Head & Neck Surgery, Medical School University of Western Australia, Perth, WA, Australia
| | - Joachim Schmutzhard
- Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Henryk Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Piotr H. Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Georg Sprinzl
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Hinrich Staecker
- Kansas University Center for Hearing and Balance Disorders, Kansas City, KS, United States
| | - Timo Stöver
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | | | - Vedat Topsakal
- Department of ENT HNS, University Hospital Brussels, Brussels, Belgium
| | - Shin-Ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Nagano, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Nora M. Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Wilhelm Wimmer
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Mario Zernotti
- Catholic University of Córdoba and National University of Córdoba, Córdoba, Argentina
| | - Javier Gavilan
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| |
Collapse
|
11
|
Canfarotta MW, Dillon MT, Brown KD, Pillsbury HC, Dedmon MM, O'Connell BP. Insertion Depth and Cochlear Implant Speech Recognition Outcomes: A Comparative Study of 28- and 31.5-mm Lateral Wall Arrays. Otol Neurotol 2022; 43:183-189. [PMID: 34772886 PMCID: PMC8752482 DOI: 10.1097/mao.0000000000003416] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES 1) To compare speech recognition outcomes between cochlear implant (CI) recipients of 28- and 31.5-mm lateral wall electrode arrays, and 2) to characterize the relationship between angular insertion depth (AID) and speech recognition. STUDY DESIGN Retrospective review. SETTING Tertiary academic referral center. PATIENTS Seventy-five adult CI recipients of fully inserted 28-mm (n = 28) or 31.5-mm (n = 47) lateral wall arrays listening with a CI-alone device. INTERVENTIONS Cochlear implantation with postoperative computed tomography. MAIN OUTCOME MEASURES Consonant-nucleus-consonant (CNC) word recognition assessed with the CI-alone at 12 months postactivation. RESULTS The mean AID of the most apical electrode contact for the 31.5-mm array recipients was significantly deeper than the 28-mm array recipients (628° vs 571°, p < 0.001). Following 12 months of listening experience, mean CNC word scores were significantly better for recipients of 31.5-mm arrays compared with those implanted with 28-mm arrays (59.5% vs 48.3%, p = 0.004; Cohen's d = 0.70; 95% CI [0.22, 1.18]). There was a significant positive correlation between AID and CNC word scores (r = 0.372, p = 0.001), with a plateau in performance observed around 600°. CONCLUSIONS Cochlear implant recipients implanted with a 31.5-mm array experienced better speech recognition than those with a 28-mm array at 12 months postactivation. Deeper insertion of a lateral wall array appears to confer speech recognition benefit up to ∼600°, with a plateau in performance observed thereafter. These data provide preliminary evidence of the insertion depth necessary to optimize speech recognition outcomes for lateral wall electrode arrays among CI-alone users.
Collapse
Affiliation(s)
- Michael W Canfarotta
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | | | | | | | | | | |
Collapse
|
12
|
Aebischer P, Mantokoudis G, Weder S, Anschuetz L, Caversaccio M, Wimmer W. In-Vitro Study of Speed and Alignment Angle in Cochlear Implant Electrode Array Insertions. IEEE Trans Biomed Eng 2021; 69:129-137. [PMID: 34110987 DOI: 10.1109/tbme.2021.3088232] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE The insertion of the electrode array is a critical step in cochlear implantation. Herein we comprehensively investigate the impact of the alignment angle and feed-forward speed on deep insertions in artificial scala tympani models with accurate macro-anatomy and controlled frictional properties. METHODS Motorized insertions (n=1033) were performed in six scala tympani models with varying speeds and alignment angles. We evaluated reaction forces and micrographs of the insertion process and developed a mathematical model to estimate the normal force distribution along the electrode arrays. RESULTS Insertions parallel to the cochlear base significantly reduce insertion energies and lead to smoother array movement. Non-constant insertion speeds allow to reduce insertion forces for a fixed total insertion time compared to a constant feed rate. CONCLUSION In cochlear implantation, smoothness and peak forces can be reduced with alignment angles parallel to the scala tympani centerline and with non-constant feed-forward speed profiles. SIGNIFICANCE Our results may help to provide clinical guidelines and improve surgical tools for manual and automated cochlear implantation.
Collapse
|
13
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for an array with large inter-electrode distances. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2752. [PMID: 33940865 PMCID: PMC8062138 DOI: 10.1121/10.0004244] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 03/22/2021] [Accepted: 03/22/2021] [Indexed: 05/28/2023]
Abstract
This study investigated the number of channels available to cochlear implant (CI) recipients for maximum speech understanding and sound quality for lateral wall electrode arrays-which result in large electrode-to-modiolus distances-featuring the greatest inter-electrode distances (2.1-2.4 mm), the longest active lengths (23.1-26.4 mm), and the fewest number of electrodes commercially available. Participants included ten post-lingually deafened adult CI recipients with MED-EL electrode arrays (FLEX28 and STANDARD) entirely within scala tympani. Electrode placement and scalar location were determined using computerized tomography. The number of channels was varied from 4 to 12 with equal spatial distribution across the array. A continuous interleaved sampling-based strategy was used. Speech recognition, sound quality ratings, and a closed-set vowel recognition task were measured acutely for each electrode condition. Participants did not demonstrate statistically significant differences beyond eight channels at the group level for almost all measures. However, several listeners showed considerable improvements from 8 to 12 channels for speech and sound quality measures. These results suggest that channel interaction caused by the greater electrode-to-modiolus distances of straight electrode arrays could be partially compensated for by a large inter-electrode distance or spacing.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
14
|
Mitchell MB, Labadie RF. Cost-Effectiveness of Intraoperative CT Scanning in Cochlear Implantation in Fee-for-Service and Bundled Payment Models. EAR, NOSE & THROAT JOURNAL 2020; 101:NP164-NP168. [PMID: 32865462 DOI: 10.1177/0145561320952192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE Electrode array tip fold-over is a complication of cochlear implant surgery that results in poor hearing outcomes and often leads to revision surgery. However, tip fold-over can be corrected immediately if identified through intraoperative computed tomography, which also potentially provides information about final intracochlear positioning. Our objective was to provide the first economic analysis of intraoperative computed tomography by generating models in fee-for-service and bundled payment reimbursement structures of payer and institutional cost-effectiveness of this technology used in cochlear implantation over 1, 5, and 10-year time periods. METHODS Cost data specific to a commerically available intraoperative computed tomography machine was obtained from the manufacturer, Xoran Technologies. Institutional tip fold-over rate was obtained from already published data. Medicare reimbursement rate for cochlear implantation was obtained from institutional accountants. Private payer reimbursement for and cost of revision cochlear implantation were estimated based on available data. RESULTS AND CONCLUSION At large volume centers, cost-effectiveness of this technology is possible in both fee-for-service and bundled payment reimbursement structures at various time points dependent on payer mix. Even low volume cochlear implantation centers (<150 per year) can financially benefit from intraoperative computed tomography in bundled payment models at 5- and 10-year periods regardless of payer mix. This model demonstrates key factors at play in determining cost-effectiveness of this technology including institutional factors and payer type and suggests this technology can align incentives both to improve patient care and outcomes with institutional and payer financial well-being.
Collapse
Affiliation(s)
- Margaret B Mitchell
- Department of Otolaryngology-Head & Neck Surgery, 1866Massachusetts Eye and Ear Infirmary, Boston, MA, USA
| | - Robert F Labadie
- Department of Otolaryngology-Head and Neck Surgery, 12328Vanderbilt University Medical Center, Nashville, TN, USA
| |
Collapse
|