Balachandran S, Cross MH, Karthikeyan S, Mulpur A, Hansbro SD, Hobson P. Retrograde autologous priming of the cardiopulmonary bypass circuit reduces blood transfusion after coronary artery surgery.
Ann Thorac Surg 2002;
73:1912-8. [PMID:
12078790 DOI:
10.1016/s0003-4975(02)03513-0]
[Citation(s) in RCA: 53] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND
Hemodilution occurring with cardiopulmonary bypass imposes a risk for blood transfusion. Autologous priming of the cardiopulmonary bypass circuit at the initiation of bypass partially replaces the priming solution with autologous blood. We examined the efficacy of autologous priming of the circuit in reducing blood transfusion.
METHODS
One hundred and four patients were entered into a prospective, randomized, controlled study. Initiation of cardiopulmonary bypass was with or without autologous priming.
RESULTS
With autologous priming, a mean volume of 808.8 +/- 159.3 mL of priming solution was replaced with autologous blood. This allowed a higher hematocrit value on admission to the intensive care unit and at discharge from hospital. In all, 49% of the control group required a blood transfusion compared with 17% from the autologous priming group (p = 0.0007). The mean volume of blood transfused was 277.6 +/- 363.8 mL in the control group compared with 70.1 +/- 173.5 mL in the autologous priming group (p = 0.0005).
CONCLUSIONS
Retrograde autologous priming of the bypass circuit reduces homologous blood transfusion owing to the reduction in bypass circuit priming volume.
Collapse