1
|
den Dekker BM, Broeders MJM, Meeuwis C, Setz-Pels W, Venmans A, van Gils CH, Pijnappel RM. Diagnostic accuracy of supplemental three-dimensional breast ultrasound in the work-up of BI-RADS 0 screening recalls. Insights Imaging 2024; 15:131. [PMID: 38816526 PMCID: PMC11139835 DOI: 10.1186/s13244-024-01714-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 05/04/2024] [Indexed: 06/01/2024] Open
Abstract
OBJECTIVE To evaluate the diagnostic accuracy of supplemental 3D automated breast ultrasound (ABUS) in the diagnostic work-up of BI-RADS 0 recalls. We hypothesized that 3D ABUS may reduce the benign biopsy rate. MATERIALS AND METHODS In this prospective multicenter diagnostic study, screening participants recalled after a BI-RADS 0 result underwent bilateral 3D ABUS supplemental to usual care: digital breast tomosynthesis (DBT) and targeted hand-held ultrasound (HHUS). Sensitivity, specificity, positive predictive value, and negative predictive value of 3D ABUS, and DBT plus HHUS, were calculated. New 3D ABUS findings and changes of management (biopsy or additional imaging) were recorded. RESULTS A total of 501 women (median age 55 years, IQR [51-64]) with 525 BI-RADS 0 lesions were included between April 2018 and March 2020. Cancer was diagnosed in 45 patients. 3D ABUS sensitivity was 72.1% (95% CI [57.2-83.4%]), specificity 84.4% (95% CI [80.8-87.4%]), PPV 29.2% (95% CI [21.4-38.5%]), and NPV 97.1% 95.0-98.4%). Sensitivity of DBT plus HHUS was 100% (95% CI [90.2-100%]), specificity 71.4% (95% CI [67.2-75.2%]), PPV 23.8% (95% CI [18.1-30.5%]) and NPV 100% (95% CI [98.7-100%]). Twelve out of 43 (27.9%) malignancies in BI-RADS 0 lesions were missed on 3D ABUS, despite being detected on DBT and/or HHUS. Supplemental 3D ABUS resulted in the detection of 57 new lesions and six extra biopsy procedures, all were benign. CONCLUSION 3D ABUS in the diagnostic work-up of BI-RADS 0 recalls may miss over a quarter of cancers detected with HHUS and/or DBT and should not be used to omit biopsy. Supplemental 3D ABUS increases the benign biopsy rate. TRIAL REGISTRATION Dutch Trial Register, available via https://www.onderzoekmetmensen.nl/en/trial/29659 CRITICAL RELEVANCE STATEMENT: Supplemental 3D automated breast ultrasound in the work-up of BI-RADS 0 recalls may miss over a quarter of cancers detected with other methods and should not be used to omit biopsy; ABUS findings did increase benign biopsy rate. KEY POINTS Automated breast ultrasound (ABUS) may miss over 25% of cancers detectable by alternative methods. Don't rely solely on 3D ABUS to assess indication for biopsy. New findings with supplemental 3D ABUS increase the benign biopsy rate.
Collapse
Affiliation(s)
- Bianca M den Dekker
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
| | - Mireille J M Broeders
- Department for Health Evidence, Radboud University Medical Center, Nijmegen, The Netherlands
- Dutch Expert Centre for Screening, Nijmegen, The Netherlands
| | - Carla Meeuwis
- Department of Radiology, Rijnstate Hospital, Arnhem, The Netherlands
| | - Wikke Setz-Pels
- Department of Radiology, Catharina Hospital, Eindhoven, The Netherlands
| | - Alexander Venmans
- Department of Radiology, Elisabeth-TweeSteden Hospital, Tilburg, The Netherlands
| | - Carla H van Gils
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Ruud M Pijnappel
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
- Dutch Expert Centre for Screening, Nijmegen, The Netherlands
| |
Collapse
|
2
|
Dan Q, Zheng T, Liu L, Sun D, Chen Y. Ultrasound for Breast Cancer Screening in Resource-Limited Settings: Current Practice and Future Directions. Cancers (Basel) 2023; 15:cancers15072112. [PMID: 37046773 PMCID: PMC10093585 DOI: 10.3390/cancers15072112] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 03/09/2023] [Accepted: 03/30/2023] [Indexed: 04/05/2023] Open
Abstract
Breast cancer (BC) is the most prevalent cancer among women globally. Cancer screening can reduce mortality and improve women’s health. In developed countries, mammography (MAM) has been primarily utilized for population-based BC screening for several decades. However, it is usually unavailable in low-resource settings due to the lack of equipment, personnel, and time necessary to conduct and interpret the examinations. Ultrasound (US) with high detection sensitivity for women of younger ages and with dense breasts has become a supplement to MAM for breast examination. Some guidelines suggest using US as the primary screening tool in certain settings where MAM is unavailable and infeasible, but global recommendations have not yet reached a unanimous consensus. With the development of smart devices and artificial intelligence (AI) in medical imaging, clinical applications and preclinical studies have shown the potential of US combined with AI in BC screening. Nevertheless, there are few comprehensive reviews focused on the role of US in screening BC in underserved conditions, especially in technological, economical, and global perspectives. This work presents the benefits, limitations, advances, and future directions of BC screening with technology-assisted and resource-appropriate strategies, which may be helpful to implement screening initiatives in resource-limited countries.
Collapse
Affiliation(s)
- Qing Dan
- Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
| | - Tingting Zheng
- Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
| | - Li Liu
- Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
| | - Desheng Sun
- Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
| | - Yun Chen
- Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
| |
Collapse
|
3
|
Zhang J, Cai L, Pan X, Chen L, Chen M, Yan D, Liu J, Luo L. Comparison and risk factors analysis of multiple breast cancer screening methods in the evaluation of breast non-mass-like lesions. BMC Med Imaging 2022; 22:202. [PMID: 36404330 PMCID: PMC9677910 DOI: 10.1186/s12880-022-00921-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 10/26/2022] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To compare multiple breast cancer screening methods for evaluating breast non-mass-like lesions (NMLs), and investigate new best screening method for breast non-mass-like lesions and the value of the lexicon of ACR BI-RADS in NML evaluation. METHODS This retrospective study examined 253 patients aged 24-68 years who were diagnosed with breast NMLs and described the lexicon of ACR BI-RADS from April 2017 to December 2019. All lesions were evaluated by HHUS, MG, and ABUS to determine BI-RADS category, and underwent pathological examination within six months or at least 2 years of follow-up. The sensitivity, specificity, accuracy, positive predictive values (PPV), and negative predictive values (NPV) of MG, HHUS and ABUS in the prediction of malignancy were compared. Independent risk factors for malignancy were assessed using non-conditional logistic regression. RESULTS HHUS, MG and ABUS findings significantly differed between benign and malignant breast NML, including internal echo, hyperechoic spot, peripheral blood flow, internal blood flow, catheter change, peripheral change, coronal features of ABUS, and structural distortion, asymmetry, and calcification in MG. ABUS is superior to MG and HHUS in sensitivity, specificity, PPV, NPV, as well as in evaluating the necessity of biopsy and accuracy in identifying malignancy. MG was superior to HHUS in specificity, PPV, and accuracy in evaluating the need for biopsy. CONCLUSIONS ABUS was superior to HHUS and MG in evaluating the need for biopsy in breast NMLs. Compared to each other, HHUS and MG had their own relative advantages. Internal blood flow, calcification, and coronal plane feature was independent risk factors in NMLs Management, and different screening methods had their own advantages in NML management. The lexicon of ACR BI-RADS could be used not only in the evaluation of mass lesions, but also in the evaluation of NML.
Collapse
Affiliation(s)
- Jianxing Zhang
- grid.258164.c0000 0004 1790 3548Department of Medical Imaging Center, The First Affiliated Hospital, Jinan University, No. 613, Huangpu Road West, Tianhe District, Guangzhou, 510630 Guangdong Province China ,grid.411866.c0000 0000 8848 7685Department of Ultrasound, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120 Guangdong Province China
| | - Lishan Cai
- grid.411866.c0000 0000 8848 7685Department of Ultrasound, The First Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 16, Jichang Road, Baiyun District, Guangzhou, 510403 Guangdong Province China
| | - Xiyang Pan
- grid.411866.c0000 0000 8848 7685Department of Ultrasound, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120 Guangdong Province China
| | - Ling Chen
- grid.411866.c0000 0000 8848 7685Department of Ultrasound, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120 Guangdong Province China
| | - Miao Chen
- grid.411866.c0000 0000 8848 7685Department of Ultrasound, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120 Guangdong Province China
| | - Dan Yan
- grid.411866.c0000 0000 8848 7685Department of Ultrasound, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120 Guangdong Province China
| | - Jia Liu
- grid.411866.c0000 0000 8848 7685Department of Ultrasound, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120 Guangdong Province China
| | - Liangping Luo
- grid.258164.c0000 0004 1790 3548Department of Medical Imaging Center, The First Affiliated Hospital, Jinan University, No. 613, Huangpu Road West, Tianhe District, Guangzhou, 510630 Guangdong Province China
| |
Collapse
|
4
|
Ibraheem SA, Mahmud R, Mohamad Saini S, Abu Hassan H, Keiteb AS, Dirie AM. Evaluation of Diagnostic Performance of Automatic Breast Volume Scanner Compared to Handheld Ultrasound on Different Breast Lesions: A Systematic Review. Diagnostics (Basel) 2022; 12:diagnostics12020541. [PMID: 35204629 PMCID: PMC8870745 DOI: 10.3390/diagnostics12020541] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 01/24/2022] [Accepted: 01/25/2022] [Indexed: 12/16/2022] Open
Abstract
Objective: To compare the diagnostic performance of the automatic breast volume scanner (ABVS) against the handheld ultrasound (HHUS) in the differential diagnosis of benign and malignant breast lesions. Methods: A systematic search and review of studies involving ABVS and HHUS for breast cancer screening were performed. The search involved the data taken from Scopus, PubMed, and science direct databases and was conducted between the year 2011 to 2020. The prospective method was used in determining the inclusion and exclusion criteria while the evidence level was determined using the BI-RADS categories for diagnostic studies. In addition, the parameters of specificity, mean age, sensitivity, tumor number, and diagnostic accuracy of the ABVS and HHUS were summarized. Results: No systematic review or randomized controlled trial were identified in the systematic search while one cross-sectional study, eight retrospective studies, and 10 prospective studies were found. Sufficient follow-up of the subjects with benign and malignant findings were made only in 10 studies, in which only two had used ABVS and HHUS after performing mammographic screening and MRI. Analysis was made of 21 studies, which included 5448 lesions (4074 benign and 1374 malignant) taken from 6009 patients. The range of sensitivity was (0.72–1.0) for ABVS and (0.62–1.0) for HHUS; the specificity range was (0.52–0.98)% for ABVS and (0.49–0.99)% for HHUS. The accuracy range among the 11 studies was (80–99)% and (59–98)% for the HHUS and ABVS, respectively. The identified tumors had a mean size of 2.1 cm, and the detected cancers had a mean percentage of 94% (81–100)% in comparison to the non-cancer in all studies. Conclusions: The evidence available in the literature points to the fact that the diagnostic performance of both ABVS and HHUS are similar with reference to the differentiation of malignant and benign breast lesions.
Collapse
Affiliation(s)
- Shahad A. Ibraheem
- Department of Radiology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Malaysia; (R.M.); (S.M.S.); (H.A.H.)
- Correspondence:
| | - Rozi Mahmud
- Department of Radiology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Malaysia; (R.M.); (S.M.S.); (H.A.H.)
- Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia, Serdang 43400, Malaysia
| | - Suraini Mohamad Saini
- Department of Radiology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Malaysia; (R.M.); (S.M.S.); (H.A.H.)
- Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia, Serdang 43400, Malaysia
| | - Hasyma Abu Hassan
- Department of Radiology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Malaysia; (R.M.); (S.M.S.); (H.A.H.)
| | - Aysar Sabah Keiteb
- Department of Radiological Techniques, College of Health and Medical Technologies, Baghdad 10047, Iraq;
| | - Ahmed M. Dirie
- Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Malaysia;
| |
Collapse
|
5
|
Güldogan N, Yılmaz E, Arslan A, Küçükkaya F, Atila N, Arıbal E. Comparison of 3D-Automated Breast Ultrasound With Handheld Breast Ultrasound Regarding Detection and BI-RADS Characterization of Lesions in Dense Breasts: A Study of 592 Cases. Acad Radiol 2021; 29:1143-1148. [PMID: 34955365 DOI: 10.1016/j.acra.2021.11.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/19/2021] [Accepted: 11/22/2021] [Indexed: 11/01/2022]
Abstract
RATIONALE AND OBJECTIVE We aimed to compare the diagnostic performance of an automated breast ultrasound system (ABUS) with handheld ultrasound (HHUS) in the detection and characterization of lesions regarding BI-RADS classification in women with dense breasts. MATERIALS AND METHODS After ethical approval, from July 2017 to August 2019, 592 consecutive patients were enrolled in this prospective study. On the same day, patients underwent ABUS followed by HHUS. Three breast radiologists participated in this study. The number and type of lesions and BI-RADS categorization of both ABUS and HHUS examinations of each patient were recorded in an excel file. The level of agreement between the two ultrasound systems in terms of lesion number and BI-RADS category were analyzed statistically. RESULTS ABUS and HHUS detected 1005 and 1491 cystic and 270 and 336 mass lesions in 592 patients respectively. ABUS and HHUS detected 171 and 167 positive/suspicious cases (BIRADS 0/3/4/5). Forty suspicious lesions underwent core needle biopsy whereas 11 malignant lesions were detected by both methods. The remaining lesions were followed with a mean of 31 months. The mean size of solid lesions detected by HHUS and ABUS was 7.67 mm (range 2.1-41 mm) and 7.74 mm (range 2-42 mm) respectively. The agreement for detection of cystic lesions between two methods for each breast was good (kappa: 0.61-0.62 p < 0.001). The agreement of two methods for solid mass lesions for each breast was moderate (k = 0.57-0.60 p < 0.001). There was good agreement between the two methods for detecting suspicious lesions (kappa = 0.66 p < 0.001). CONCLUSION The level of agreement of ABUS and HHUS for dichotomic assignment of BIRADS categories was good. Although ABUS detected fewer lesions compared to HHUS, both methods detected all malignant lesions. ABUS is a reliable method for the detection of malignancy in dense breasts.
Collapse
|
6
|
Chen H, Han M, Jing H, Liu Z, Shang H, Wang Q, Cheng W. Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG). Int J Gen Med 2021; 14:9193-9202. [PMID: 34880658 PMCID: PMC8647168 DOI: 10.2147/ijgm.s342567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 11/19/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose This study aimed to evaluate the dependability of automated breast ultrasound (ABUS) compared with handheld ultrasound (HHUS) and mammography (MG) on the Breast Imaging Reporting and Data System (BI-RADS) category and size assessment of malignant breast lesions. Patients and Methods A total of 344 confirmed malignant lesions were recruited. All participants underwent MG, HHUS, and ABUS examinations. Agreements on the BI-RADS category were evaluated. Lesion size assessed using the three methods was compared with the size of the pathological result as the control. Regarding the four major molecular subtypes, correlation coefficients between size on imaging and pathology were also evaluated. Results The agreement between ABUS and HHUS on the BI-RADS category was 86.63% (kappa = 0.77), whereas it was 32.22% (kappa = 0.10) between ABUS and MG. Imaging lesion size compared to pathologic lesion size was assessed correctly in 36.92%/52.91% (ABUS), 33.14%/48.84% (HHUS) and 33.44%/43.87% (MG), with the threshold of 3 mm/5 mm, respectively. The correlation coefficient of size of ABUS-Pathology (0.75, Spearman) was statistically higher than that of the MG-Pathology (0.58, Spearman) with P < 0.01, but not different from that of the HHUS-Pathology (0.74, Spearman) with P > 0.05. The correlation coefficient of ABUS-Pathology was statistically higher than that of MG-Pathology in the triple-negative subtype, luminal B subtype, and luminal A subtype (P<0.01). Conclusion The agreement between ABUS and HHUS in the BI-RADS category was good, whereas that between ABUS and MG was poor. ABUS and HHUS allowed a more accurate assessment of malignant tumor size compared to MG.
Collapse
Affiliation(s)
- He Chen
- Department of Ultrasound, Harbin Medical University Cancer Hospital, Harbin City, Heilongjiang Province, People's Republic of China
| | - Ming Han
- Department of General Surgery, Heji Hospital of Changzhi Medical College, Changzhi City, Shanxi Province, People's Republic of China
| | - Hui Jing
- Department of Ultrasound, Harbin Medical University Cancer Hospital, Harbin City, Heilongjiang Province, People's Republic of China
| | - Zhao Liu
- Department of Ultrasound, Harbin Medical University Cancer Hospital, Harbin City, Heilongjiang Province, People's Republic of China
| | - Haitao Shang
- Department of Ultrasound, Harbin Medical University Cancer Hospital, Harbin City, Heilongjiang Province, People's Republic of China
| | - Qiucheng Wang
- Department of Ultrasound, Harbin Medical University Cancer Hospital, Harbin City, Heilongjiang Province, People's Republic of China
| | - Wen Cheng
- Department of Ultrasound, Harbin Medical University Cancer Hospital, Harbin City, Heilongjiang Province, People's Republic of China
| |
Collapse
|
7
|
Zhang J, Cai L, Chen L, Pang X, Chen M, Yan D, Liu J, Luo L. Re-evaluation of high-risk breast mammography lesions by target ultrasound and ABUS of breast non-mass-like lesions. BMC Med Imaging 2021; 21:156. [PMID: 34702200 PMCID: PMC8549220 DOI: 10.1186/s12880-021-00665-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 09/06/2021] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE The purpose of this study was to reevaluate the high-risk breast non-mass-like lesions (NMLs) in mammography (MG) by target ultrasound (US) and Automated breast ultrasonography (ABUS), and to analyze the correlation between different imaging findings and the factors influencing the classification of lesions. METHODS A total of 161 patients with 166 breast lesions were recruited in this retrospectively study. All cases were diagnosed as BI-RADS 4 or 5 by MG and as NML on ultrasound. While all NMLs underwent mammography, target US and ABUS before breast surgery or biopsy in the consistent position of breast. The imaging and pathological features of all cases were collected. All lesions were classified according to the lexion of ACR BI-RADS®. RESULTS There were significant differences between benign and malignant breast NML in all the features of target US and ABUS. US, especially ABUS, was superior to MG in determining the malignant breast NML. There was a significant difference in the detection rate of calcification between MG and Target US (P < 0.001), and there was a significant difference in the detection rate of structural distortion between ABUS and MG (P < 0.001). CONCLUSIONS Target US, especially ABUS, can significantly improve the sensitivity, specificity and accuracy of the diagnosis of high-risk NMLs in MG. The features of Target US and ABUS such as blood supply, hyperechogenicity, ductal changes, peripheral changes and coronal features could be employed to predict benign and malignant lesions. The coronal features of ABUS were more sensitive than those of Target HHUS in showing structural abnormalities. Target US was less effective than MG in local micro-calcification.
Collapse
Affiliation(s)
- Jianxing Zhang
- Department of Medical Imaging Center, Jinan University First Affiliated Hospital, No. 613, Huangpu Road West, Tianhe District, Guangzhou, 510630, Guangdong Province, China.
- Department of Ultrasound, 2Nd Clinical Hospital of Guangzhou Chinese Traditional Medicine College: Guangdong Provincial Hospital of Traditional Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120, Guangdong Province, China.
| | - Lishang Cai
- Department of Ultrasound, Guangzhou University of Traditional Chinese Medicine First Affiliated Hospital, No. 16, Jichang Road, Baiyun District, Guangzhou, 510403, Guangdong Province, China
| | - Ling Chen
- Department of Ultrasound, 2Nd Clinical Hospital of Guangzhou Chinese Traditional Medicine College: Guangdong Provincial Hospital of Traditional Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120, Guangdong Province, China
| | - Xiyan Pang
- Department of Ultrasound, 2Nd Clinical Hospital of Guangzhou Chinese Traditional Medicine College: Guangdong Provincial Hospital of Traditional Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120, Guangdong Province, China
| | - Miao Chen
- Department of Ultrasound, 2Nd Clinical Hospital of Guangzhou Chinese Traditional Medicine College: Guangdong Provincial Hospital of Traditional Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120, Guangdong Province, China
| | - Dan Yan
- Department of Ultrasound, 2Nd Clinical Hospital of Guangzhou Chinese Traditional Medicine College: Guangdong Provincial Hospital of Traditional Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120, Guangdong Province, China
| | - Jia Liu
- Department of Ultrasound, 2Nd Clinical Hospital of Guangzhou Chinese Traditional Medicine College: Guangdong Provincial Hospital of Traditional Chinese Medicine, No. 111, Dade Road, Yuexiu District, Guangzhou, 510120, Guangdong Province, China
| | - Liangping Luo
- Department of Medical Imaging Center, Jinan University First Affiliated Hospital, No. 613, Huangpu Road West, Tianhe District, Guangzhou, 510630, Guangdong Province, China.
| |
Collapse
|
8
|
Pros and Cons for Automated Breast Ultrasound (ABUS): A Narrative Review. J Pers Med 2021; 11:jpm11080703. [PMID: 34442347 PMCID: PMC8400952 DOI: 10.3390/jpm11080703] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 07/21/2021] [Accepted: 07/22/2021] [Indexed: 12/15/2022] Open
Abstract
Automated breast ultrasound (ABUS) is an ultrasound technique that tends to be increasingly used as a supplementary technique in the evaluation of patients with dense glandular breasts. Patients with dense breasts have an increased risk of developing breast cancer compared to patients with fatty breasts. Furthermore, for this group of patients, mammography has a low sensitivity in detecting breast cancers, especially if it is not associated with architectural distortion or calcifications. ABUS is a standardized examination with many advantages in both screening and diagnostic settings: it increases the detection rate of breast cancer, improves the workflow, and reduces the examination time. On the other hand, like any imaging technique, ABUS has disadvantages and even some limitations. Many disadvantages can be diminished by additional attention and training. Disadvantages regarding image acquisition are the inability to assess the axilla, the vascularization, and the elasticity of a lesion, while concerning the interpretation, the disadvantages are the artifacts due to poor positioning, lack of contact, motion or lesion related. This article reviews and discusses the indications, the advantages, and disadvantages of the method and also the sources of error in the ABUS examination.
Collapse
|
9
|
A multicenter, hospital-based and non-inferiority study for diagnostic efficacy of automated whole breast ultrasound for breast cancer in China. Sci Rep 2021; 11:13902. [PMID: 34230562 PMCID: PMC8260602 DOI: 10.1038/s41598-021-93350-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 06/17/2021] [Indexed: 12/30/2022] Open
Abstract
This study is the first multi-center non-inferiority study that aims to critically evaluate the effectiveness of HHUS/ABUS in China breast cancer detection. This was a multicenter hospital-based study. Five hospitals participated in this study. Women (30–69 years old) with defined criteria were invited for breast examination by HHUS, ABUS or/and mammography. For BI-RADS category 3, an additional magnetic resonance imaging (MRI) test was provided to distinguish the true negative results from false negative results. For women classified as BI-RADS category 4 or 5, either core aspiration biopsy or surgical biopsy was done to confirm the diagnosis. Between February 2016 and March 2017, 2844 women signed the informed consent form, and 1947 of them involved in final analysis (680 were 30 to 39 years old, 1267 were 40 to 69 years old).For all participants, ABUS sensitivity (91.81%) compared with HHUS sensitivity (94.70%) with non-inferior Z tests, P = 0.015. In the 40–69 age group, non-inferior Z tests showed that ABUS sensitivity (93.01%) was non-inferior to MG sensitivity (86.02%) with P < 0.001 and HHUS sensitivity (95.44%) was non-inferior to MG sensitivity (86.02%) with P < 0.001. Sensitivity of ABUS and HHUS are all superior to that of MG with P < 0.001 by superior test.For all participants, ABUS specificity (92.89%) was non-inferior to HHUS specificity (89.36%) with P < 0.001. Superiority test show that specificity of ABUS was superior to that of HHUS with P < 0.001. In the 40–69 age group, ABUS specificity (92.86%) was non-inferior to MG specificity (91.68%) with P < 0.001 and HHUS specificity (89.55%) was non-inferior to MG specificity (91.68%) with P < 0.001. ABUS is not superior to MG with P = 0.114 by superior test. The sensitivity of ABUS/HHUS is superior to that of MG. The specificity of ABUS/HHUS is non-inferior to that of MG. In China, for an experienced US radiologist, both HHUS and ABUS have better diagnostic efficacy than MG in symptomatic individuals.
Collapse
|
10
|
Allajbeu I, Hickman SE, Payne N, Moyle P, Taylor K, Sharma N, Gilbert FJ. Automated Breast Ultrasound: Technical Aspects, Impact on Breast Screening, and Future Perspectives. CURRENT BREAST CANCER REPORTS 2021. [DOI: 10.1007/s12609-021-00423-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Abstract
Purpose of Review
Automated breast ultrasound (ABUS) is a three-dimensional imaging technique, used as a supplemental screening tool in women with dense breasts. This review considers the technical aspects, pitfalls, and the use of ABUS in screening and clinical practice, together with new developments and future perspectives.
Recent Findings
ABUS has been approved in the USA and Europe as a screening tool for asymptomatic women with dense breasts in addition to mammography. Supplemental US screening has high sensitivity for cancer detection, especially early-stage invasive cancers, and reduces the frequency of interval cancers. ABUS has similar diagnostic performance to handheld ultrasound (HHUS) and is designed to overcome the drawbacks of operator dependence and poor reproducibility. Concerns with ABUS, like HHUS, include relatively high recall rates and lengthy reading time when compared to mammography. ABUS is a new technique with unique features; therefore, adequate training is required to improve detection and reduce false positives. Computer-aided detection may reduce reading times and improve cancer detection. Other potential applications of ABUS include local staging, treatment response evaluation, breast density assessment, and integration of radiomics.
Summary
ABUS provides an efficient, reproducible, and comprehensive supplemental imaging technique in breast screening. Developments with computer-aided detection may improve the sensitivity and specificity as well as radiologist confidence and reduce reading times, making this modality acceptable in large volume screening centers.
Collapse
|
11
|
Philadelpho F, Calas MJG, Carneiro GDAC, Silveira IC, Vaz ABR, Nogueira AMC, Bergmann A, Lopes FPPL. Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts. REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRÍCIA 2021; 43:190-199. [PMID: 33860502 PMCID: PMC10183872 DOI: 10.1055/s-0040-1722156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
OBJECTIVE To compare hand-held breast ultrasound (HHBUS) and automated breast ultrasound (ABUS) as screening tool for cancer. METHODS A cross-sectional study in patients with mammographically dense breasts was conducted, and both HHBUS and ABUS were performed. Hand-held breast ultrasound was acquired by radiologists and ABUS by mammography technicians and analyzed by breast radiologists. We evaluated the Breast Imaging Reporting and Data System (BI-RADS) classification of the exam and of the lesion, as well as the amount of time required to perform and read each exam. The statistical analysis employed was measures of central tendency and dispersion, frequencies, Student t test, and a univariate logistic regression, through the odds ratio and its respective 95% confidence interval, and with p < 0.05 considered of statistical significance. RESULTS A total of 440 patients were evaluated. Regarding lesions, HHBUS detected 15 (7.7%) BI-RADS 2, 175 (89.3%) BI-RADS 3, and 6 (3%) BI-RADS 4, with 3 being confirmed by biopsy as invasive ductal carcinomas (IDCs), and 3 false-positives. Automated breast ultrasound identified 12 (12.9%) BI-RADS 2, 75 (80.7%) BI-RADS 3, and 6 (6.4%) BI-RADS 4, including 3 lesions detected by HHBUS and confirmed as IDCs, in addition to 1 invasive lobular carcinoma and 2 high-risk lesions not detected by HHBUS. The amount of time required for the radiologist to read the ABUS was statistically inferior compared with the time required to read the HHBUS (p < 0.001). The overall concordance was 80.9%. A total of 219 lesions were detected, from those 70 lesions by both methods, 126 only by HHBUS (84.9% not suspicious by ABUS) and 23 only by ABUS. CONCLUSION Compared with HHBUS, ABUS allowed adequate sonographic study in supplemental screening for breast cancer in heterogeneously dense and extremely dense breasts.
Collapse
Affiliation(s)
- Fernanda Philadelpho
- Radiology Department, Diagnósticos da América (DASA), Barra da Tijuca, RJ, Brazil
| | | | | | | | | | | | - Anke Bergmann
- Radiology Department, Diagnósticos da América (DASA), Barra da Tijuca, RJ, Brazil.,Clinical Epidemiology Program, Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ, Brazil
| | - Flávia Paiva Proença Lobo Lopes
- Radiology Department, Diagnósticos da América (DASA), Barra da Tijuca, RJ, Brazil.,Radiology Department, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| |
Collapse
|
12
|
Classification of breast ultrasound with human-rating BI-RADS scores using mined diagnostic patterns and optimized neuro-network. Neurocomputing 2020. [DOI: 10.1016/j.neucom.2020.07.104] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
13
|
Calas MJG, Pereira FPA, Gonçalves LP, Lopes FPPL. Preliminary study of the technical limitations of automated breast ultrasound: from procedure to diagnosis. Radiol Bras 2020; 53:293-300. [PMID: 33071372 PMCID: PMC7545727 DOI: 10.1590/0100-3984.2019.0079] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Objective To evaluate the main technical limitations of automated breast ultrasound and to determine the proportion of examinations excluded. Materials and Methods We evaluated 440 automated breast ultrasound examinations performed, over a 12-month period, by technicians using an established protocol. Results In five cases (1.1%), the examination was deemed unacceptable for diagnostic purposes, those examinations therefore being excluded. Conclusion Automated breast ultrasound is expected to overcome some of the major limitations of conventional ultrasound in breast cancer screening. In Brazil, this new method can be accepted for inclusion in routine clinical practice only after its advantages have been validated in the national context.
Collapse
|
14
|
Lin X, Jia M, Zhou X, Bao L, Chen Y, Liu P, Feng R, Zhang X, Zhu L, Wang H, Zhu Y, Tang G, Feng W, Li A, Qiao Y. The diagnostic performance of automated versus handheld breast ultrasound and mammography in symptomatic outpatient women: a multicenter, cross-sectional study in China. Eur Radiol 2020; 31:947-957. [PMID: 32852589 DOI: 10.1007/s00330-020-07197-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/04/2020] [Accepted: 08/14/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES The purpose of this study was to evaluate the diagnostic performance of automated breast ultrasound (ABUS) for breast cancer by comparing it to handheld ultrasound (HHUS) and mammography (MG). METHODS A multicenter cross-sectional study was conducted between February 2016 and March 2017 in five tertiary hospitals in China, and 1922 women aged 30-69 years old were recruited. Women aged 30-39 years (group A) underwent ABUS and HHUS, and women aged 40-69 (group B) underwent additional MG. Images were interpreted using the Breast Imaging Reporting and Data System (BI-RADS). All BI-RADS 4 and 5 cases were confirmed pathologically. Sensitivities and specificities of all modalities were compared. RESULTS There were 83 cancers in 677 women in group A and 321 cancers in 1245 women in group B. In the whole study population, the sensitivities of ABUS and HHUS were 92.8% (375/404) and 96.3% (389/404), and the specificities were 93.0% (1411/1518) and 89.6% (1360/1518), respectively. ABUS had a significantly higher specificity to HHUS (p < 0.01), while HHUS had higher sensitivity (p = 0.01). In group B, the sensitivities of ABUS, HHUS, and MG were 93.5% (300/321), 96.6% (310/321), and 87.9% (282/321). The specificities were 93.0% (859/924), 89.9% (831/924), and 91.6% (846/924). ABUS had significantly higher sensitivity (p = 0.02) and comparable specificity compared with MG (p = 0.14). CONCLUSION ABUS increased sensitivity and had similar specificity compared with mammography in the diagnosis of breast cancer. Additionally, ABUS has comparable performance to HHUS in women aged 30-69 years old. ABUS or HHUS is a suitable modality for breast cancer diagnosis. KEY POINTS • In breast cancer diagnosis settings, automated breast ultrasound has a higher cancer detection rate, sensitivity, and specificity than mammography, especially in women with dense breasts. • Compared with handheld ultrasound, automated breast ultrasound has higher specificity, lower sensitivity, and comparable diagnostic performance. • Automated breast ultrasound is a suitable modality for breast cancer diagnosis, and may have a potential indication for its further use in the breast cancer early detection.
Collapse
Affiliation(s)
- Xi Lin
- Department of Ultrasound, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, China
| | - Mengmeng Jia
- Department of Epidemiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Xiang Zhou
- Department of Interventional Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Lingyun Bao
- Department of Ultrasound, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, China
| | - Yaqing Chen
- Department of Ultrasound, Xin Hua Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200092, China
| | - Peifang Liu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, China
| | - Ruimei Feng
- Department of Cancer Prevention Research, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, China
| | - Xi Zhang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Beijing Office for Cancer Prevention and Control, Peking University Cancer Hospital and Institute, Beijing, 100142, China
| | - Luoxi Zhu
- Department of Ultrasound, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, China
| | - Hui Wang
- Department of Ultrasound, Xin Hua Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200092, China
| | - Ying Zhu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, China
| | - Guoxue Tang
- Department of Ultrasound, Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, 510120, China
| | - Wenqi Feng
- Department of Ultrasound, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Anhua Li
- Department of Ultrasound, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, China.
| | - Youlin Qiao
- Department of Epidemiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China. .,School of Population Medicine and Public Health, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China.
| |
Collapse
|
15
|
Nicosia L, Ferrari F, Bozzini AC, Latronico A, Trentin C, Meneghetti L, Pesapane F, Pizzamiglio M, Balesetreri N, Cassano E. Automatic breast ultrasound: state of the art and future perspectives. Ecancermedicalscience 2020; 14:1062. [PMID: 32728378 PMCID: PMC7373644 DOI: 10.3332/ecancer.2020.1062] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Indexed: 11/08/2022] Open
Abstract
The three-dimensional automated breast ultrasound system (3D ABUS) is a new device which represents a huge innovation in the breast ultrasound field, with several application scenarios of great interest. ABUS's aim is to solve some of the main defects of traditional ultrasound, such as lack of standardization, high level of skill non-reproducibility, small field of view and high commitment of physician time. ABUS has proven to be an excellent non-ionising alternative to other supplemental screening options for women with dense breast tissue; also, it has appeared to be very promising in daily clinical practice. The purpose of this paper is to present a summary of current applications of ABUS, focusing on clinical applications and future perspectives as ABUS is particularly promising for studies involving artificial intelligence, radiomics and evaluation of breast molecular subtypes.
Collapse
Affiliation(s)
- Luca Nicosia
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Federica Ferrari
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy
| | - Anna Carla Bozzini
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Antuono Latronico
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Chiara Trentin
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Lorenza Meneghetti
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Filippo Pesapane
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Maria Pizzamiglio
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Nicola Balesetreri
- Department of Radiology, European Institute of Oncology, 20141 Milan, Italy
| | - Enrico Cassano
- Department of Breast Radiology, European Institute of Oncology, 20141 Milan, Italy
| |
Collapse
|
16
|
Depretto C, Liguori A, Primolevo A, Di Cosimo S, Cartia F, Ferranti C, Scaperrotta GP. Automated breast ultrasound compared to hand-held ultrasound in surveillance after breast-conserving surgery. TUMORI JOURNAL 2020; 107:132-138. [PMID: 32552398 DOI: 10.1177/0300891620930278] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To investigate the agreement between automated breast ultrasound (ABUS) and hand-held ultrasound (HHUS) in surveillance of women with a history of breast cancer in terms of recurrences or new ipsilateral or contralateral breast cancer. METHODS The institutional review board approved this retrospective study and informed consent was waived. From April to June 2016, women with dense breasts undergoing annual surveillance with mammography and HHUS after breast-conserving surgery were offered supplemental ABUS (Invenia). HHUS was performed by a breast radiologist and ABUS by a trained technician. Images were reviewed by 2 breast radiologists. A per-patient BI-RADS category was independently assigned in all cases and categories were dichotomized into negative (1, 2, 3) and positive (4, 5). Cohen κ, McNemar, and Wilcoxon statistics were used. Final pathology was used as reference standard for malignant lesions. RESULTS A total of 154 women (mean age 62±11 years) were enrolled. Time from surgery was a mean of 8±6 years. Cancer prevalence was 4/154 (2.6%). Interreader agreement for ABUS was 1. Intermethod interreader agreement for HHUS and ABUS was substantial for BI-RADS categories (κ = 0.785) and for dichotomic assessment (κ = 0.794). There was no difference in dichotomic assignment between 2 readers (p = 0.5) but a significant difference in assigning BI-RADS categories (p < 0.05). CONCLUSIONS A substantial agreement resulted between HHUS and ABUS in surveillance of women with a previous history of breast cancer. In particular, ABUS recognized all cancers detected by HHUS and could play a role in first-level surveillance of women at intermediate risk.
Collapse
Affiliation(s)
| | | | | | - Serena Di Cosimo
- Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, Milano, Italy
| | - Francesco Cartia
- Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, Milano, Italy
| | - Claudio Ferranti
- Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, Milano, Italy
| | | |
Collapse
|
17
|
Screening Breast Ultrasound: Update After 10 Years of Breast Density Notification Laws. AJR Am J Roentgenol 2020; 214:1424-1435. [DOI: 10.2214/ajr.19.22275] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
18
|
Kim Y, Rim J, Kim SM, Yun BL, Park SY, Ahn HS, Kim B, Jang M. False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients. Ultrasonography 2020; 40:83-92. [PMID: 32422696 PMCID: PMC7758101 DOI: 10.14366/usg.19076] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 03/24/2020] [Indexed: 01/19/2023] Open
Abstract
Purpose The purpose of this study was to measure the cancer detection rate of computer-aided detection (CAD) software in preoperative automated breast ultrasonography (ABUS) of breast cancer patients and to determine the characteristics associated with false-negative outcomes. Methods A total of 129 index lesions (median size, 1.7 cm; interquartile range, 1.2 to 2.4 cm) from 129 consecutive patients (mean age±standard deviation, 53.4±11.8 years) who underwent preoperative ABUS from December 2017 to February 2018 were assessed. An index lesion was defined as a breast cancer confirmed by ultrasonography (US)-guided core needle biopsy. The detection rate of the index lesions, positive predictive value (PPV), and false-positive rate (FPR) of the CAD software were measured. Subgroup analysis was performed to identify clinical and US findings associated with false-negative outcomes. Results The detection rate of the CAD software was 0.84 (109 of 129; 95% confidence interval, 0.77 to 0.90). The PPV and FPR were 0.41 (221 of 544; 95% CI, 0.36 to 0.45) and 0.45 (174 of 387; 95% CI, 0.40 to 0.50), respectively. False-negative outcomes were more frequent in asymptomatic patients (P<0.001) and were associated with the following US findings: smaller size (P=0.001), depth in the posterior third (P=0.002), angular or indistinct margin (P<0.001), and absence of architectural distortion (P<0.001). Conclusion The CAD software showed a promising detection rate of breast cancer. However, radiologists should judge whether CAD software-marked lesions are true- or false-positive lesions, considering its low PPV and high FPR. Moreover, it would be helpful for radiologists to consider the characteristics associated with false-negative outcomes when reading ABUS with CAD.
Collapse
Affiliation(s)
- Youngjune Kim
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.,Aerospace Medical Group, Air Force Education and Training Command, Jinju, Korea
| | - Jiwon Rim
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Sun Mi Kim
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.,Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Bo La Yun
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - So Yeon Park
- Department of Pathology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea
| | - Hye Shin Ahn
- Department of Radiology, Chung-Ang University Hospital,ChungAng University College of Medicine, Seoul, Korea
| | - Bohyoung Kim
- Division of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Korea
| | - Mijung Jang
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| |
Collapse
|
19
|
Sood R, Rositch AF, Shakoor D, Ambinder E, Pool KL, Pollack E, Mollura DJ, Mullen LA, Harvey SC. Ultrasound for Breast Cancer Detection Globally: A Systematic Review and Meta-Analysis. J Glob Oncol 2020; 5:1-17. [PMID: 31454282 PMCID: PMC6733207 DOI: 10.1200/jgo.19.00127] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE Mammography is not always available or feasible. The purpose of this systematic review and meta-analysis is to assess the diagnostic performance of ultrasound as a primary tool for early detection of breast cancer. MATERIALS AND METHODS For this systematic review and meta-analysis, we comprehensively searched PubMed and SCOPUS to identify articles from January 2000 to December 2018 that included data on the performance of ultrasound for detection of breast cancer. Studies evaluating portable, handheld ultrasound as an independent detection modality for breast cancer were included. Quality assessment and bias analysis were performed with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity analyses and meta-regression were used to explore heterogeneity. The study protocol has been registered with the international prospective register of systematic reviews (PROSPERO identifier: CRD42019127752). RESULTS Of the 526 identified studies, 26 were eligible for inclusion. Ultrasound had an overall pooled sensitivity and specificity of 80.1% (95% CI, 72.2% to 86.3%) and 88.4% (95% CI, 79.8% to 93.6%), respectively. When only low- and middle-income country data were considered, ultrasound maintained a diagnostic sensitivity of 89.2% and specificity of 99.1%. Meta-analysis of the included studies revealed heterogeneity. The high sensitivity of ultrasound for the detection of breast cancer was not statistically significantly different in subgroup analyses on the basis of mean age, risk, symptoms, study design, bias level, and study setting. CONCLUSION Given the increasing burden of breast cancer and infeasibility of mammography in certain settings, we believe these results support the potential use of ultrasound as an effective primary detection tool for breast cancer, which may be beneficial in low-resource settings where mammography is unavailable.
Collapse
Affiliation(s)
- Rupali Sood
- Johns Hopkins Medicine, Baltimore, MD.,RAD-AID International, Chevy Chase, MD
| | - Anne F Rositch
- The Johns Hopkins Bloomberg School of Public Health, Baltimore, MD
| | | | | | - Kara-Lee Pool
- RAD-AID International, Chevy Chase, MD.,University of California, Los Angeles, CA
| | - Erica Pollack
- RAD-AID International, Chevy Chase, MD.,Denver Health Medical Center, Denver, CO
| | | | | | - Susan C Harvey
- Johns Hopkins Medicine, Baltimore, MD.,RAD-AID International, Chevy Chase, MD
| |
Collapse
|
20
|
Mussetto I, Gristina L, Schiaffino S, Tosto S, Raviola E, Calabrese M. Breast ultrasound: automated or hand-held? Exploring patients' experience and preference. Eur Radiol Exp 2020; 4:12. [PMID: 32040784 PMCID: PMC7010878 DOI: 10.1186/s41747-019-0136-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Accepted: 11/20/2019] [Indexed: 11/29/2022] Open
Abstract
Background Our aim was to compare women’s experience with automated breast ultrasound (ABUS) versus breast hand-held ultrasound (HHUS) and to evaluate their acceptance rate. Methods After ethical approval, from October 2017 to March 2018, 79 consecutive patients were enrolled in this prospective study. On the same day, patients underwent HHUS followed by ABUS. Each patient’s experience was assessed using the modified testing morbidities index (TMI) (the lower the score, the better is the experience). Nine items were assessed for both techniques: seven directly related to the examination technique (pain or discomfort immediately before (preparation), during and after testing, fear or anxiety immediately before (preparation) and during testing, physical and mental function after testing) and two indirectly related to the examination technique (embarrassment during testing and overall satisfaction). Finally, we asked patients to choose between the two techniques for a potential next breast examination. Wilcoxon signed ranks test was used. Results The median TMI score for the seven items was found to be significantly better for HHUS (8, interquartile range [IQR] 7–11) compared to ABUS (9, IQR 8–12) (p = 0.003). The item ‘pain/discomfort during the test’ (p < 0.001) was significantly higher for ABUS compared to HHUS. Instead, the item ‘fear/anxiety before the test’ was higher for HHUS (p = 0.001). Overall, 40.5% of the patients chose HHUS, 29.1% chose ABUS, and 30.4% were unable to choose. Conclusions ABUS and HHUS exams were well tolerated and accepted. However, HHUS was perceived to be less painful than ABUS.
Collapse
Affiliation(s)
- Ilaria Mussetto
- School of Radiology, University of Genoa, Department of Health Sciences DISSAL, Via Antonio Pastore 1, 16132, Genoa, Italy.
| | - Licia Gristina
- Diagnostic Senology, IRCCS - Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, Italy
| | - Simone Schiaffino
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, San Donato Milanese, 20097, Milan, Italy
| | - Simona Tosto
- Diagnostic Senology, IRCCS - Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, Italy
| | - Edoardo Raviola
- Università Vita-Salute, San Raffaele, Via Olgettina 58, 20132, Milan, Italy
| | - Massimo Calabrese
- Diagnostic Senology, IRCCS - Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, Italy
| |
Collapse
|
21
|
Green CA, Goodsitt MM, Roubidoux MA, Brock KK, Davis CL, Lau JH, Carson PL. Deformable mapping using biomechanical models to relate corresponding lesions in digital breast tomosynthesis and automated breast ultrasound images. Med Image Anal 2020; 60:101599. [DOI: 10.1016/j.media.2019.101599] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 10/24/2019] [Accepted: 10/31/2019] [Indexed: 11/25/2022]
|
22
|
Berg WA, Vourtsis A. Screening Breast Ultrasound Using Handheld or Automated Technique in Women with Dense Breasts. JOURNAL OF BREAST IMAGING 2019; 1:283-296. [PMID: 38424808 DOI: 10.1093/jbi/wbz055] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 08/01/2019] [Indexed: 03/02/2024]
Abstract
In women with dense breasts (heterogeneously or extremely dense), adding screening ultrasound to mammography increases detection of node-negative invasive breast cancer. Similar incremental cancer detection rates averaging 2.1-2.7 per 1000 have been observed for physician- and technologist-performed handheld ultrasound (HHUS) and automated ultrasound (AUS). Adding screening ultrasound (US) for women with dense breasts significantly reduces interval cancer rates. Training is critical before interpreting examinations for both modalities, and a learning curve to achieve optimal performance has been observed. On average, about 3% of women will be recommended for biopsy on the prevalence round because of screening US, with a wide range of 2%-30% malignancy rates for suspicious findings seen only on US. Breast Imaging Reporting and Data System 3 lesions identified only on screening HHUS can be safely followed at 1 year rather than 6 months. Computer-aided detection and diagnosis software can augment performance of AUS and HHUS; ongoing research on machine learning and deep learning algorithms will likely improve outcomes and workflow with screening US.
Collapse
Affiliation(s)
- Wendie A Berg
- University of Pittsburgh School of Medicine, Magee-Womens Hospital of the University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, PA
| | - Athina Vourtsis
- Diagnostic Mammography Medical Diagnostic Imaging Unit, Athens, Greece
| |
Collapse
|
23
|
Zhang X, Chen J, Zhou Y, Mao F, Lin Y, Shen S, Sun Q, Ouyang Z. Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a meta-analysis. Gland Surg 2019; 8:698-711. [PMID: 32042678 DOI: 10.21037/gs.2019.11.18] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Background The diagnostic performance of an automated breast volume scanner (ABVS) compared with that of a hand-held ultrasound (HHUS) for breast cancer remains unclear. We performed a meta-analysis to compare the diagnostic performances of the ABVS and HHUS for breast cancer. Methods We searched PubMed, EMBASE, Cochrane, and SinoMed databases to identify eligible studies up until November 14, 2018. Studies comparing ABVS and HHUS for differentiating benign and malignant breast tumors were included. A meta-analysis was performed to generate pooled diagnostic accuracy parameters [sensitivity, specificity, diagnostic odds ratio (DOR), area under the curve (AUC), and the Q* index] and detection rates for ABVS and HHUS. Results Nine studies involving 1,376 patients and 1,527 lesions were included in the meta-analysis for diagnostic accuracy. The pooled sensitivity was 0.93 [95% confidence interval (CI), 0.91-0.95] for ABVS and 0.90 (95% CI, 0.88-0.92) for HHUS, and the pooled specificity was 0.86 (95% CI, 0.83-0.88) for ABVS and 0.82 (95% CI, 0.79-0.84) for HHUS. The pooled DOR was 88.66 (95% CI, 51.44-152.78) for ABVS and 41.06 for HHUS (95% CI, 26.58-63.42). The AUC of the summary receiver operating characteristic (SROC) was 0.9496 for ABVS and 0.9143 for HHUS, and the Q* index was 0.8899 for ABVS and 0.8469 for HHUS. Meta-regression showed no significant difference between the diagnostic accuracy of ABVS and HHUS (P=0.0771). No publication bias was found. Thirteen published studies involving 1,047 pathologically confirmed malignant lesions were included to generate a pooled detection rate. The pooled detection rate was 1.00 (95% CI, 1.00-1.00) for both ABVS and HHUS, for which a publication bias was found. Conclusions ABVS can be used as an appropriate screening tool for breast cancer as well as HHUS in diagnostic accuracy and detection rate. Considering other advantages of ABVS including non-radioactivity, sensitivity to dense breast, three-dimensional reconstruction, time-saving and repeatability, it might be a promising screening tool for young or dense-breast women in the future.
Collapse
Affiliation(s)
- Xiaohui Zhang
- Department of Breast Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences (CAMS) & Peking Union Medical College, Beijing 100032, China
| | - Juan Chen
- Institute of Medical Information/Medical Library, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100020, China
| | - Yidong Zhou
- Department of Breast Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences (CAMS) & Peking Union Medical College, Beijing 100032, China
| | - Feng Mao
- Department of Breast Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences (CAMS) & Peking Union Medical College, Beijing 100032, China
| | - Yan Lin
- Department of Breast Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences (CAMS) & Peking Union Medical College, Beijing 100032, China
| | - Songjie Shen
- Department of Breast Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences (CAMS) & Peking Union Medical College, Beijing 100032, China
| | - Qiang Sun
- Department of Breast Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences (CAMS) & Peking Union Medical College, Beijing 100032, China
| | - Zhaolian Ouyang
- Institute of Medical Information/Medical Library, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100020, China
| |
Collapse
|
24
|
Wang L, Qi ZH. Automatic Breast Volume Scanner versus Handheld Ultrasound in Differentiation of Benign and Malignant Breast Lesions: A Systematic Review and Meta-analysis. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1874-1881. [PMID: 31130410 DOI: 10.1016/j.ultrasmedbio.2019.04.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 01/29/2019] [Accepted: 04/29/2019] [Indexed: 06/09/2023]
Abstract
The goal of the study described here was to compare the automatic breast volume scanner (ABVS) and handheld ultrasound (HHUS) with respect to diagnostic performance in the differential diagnosis of benign and malignant breast lesions. A literature search of the PubMed, EMBASE and Cochrane Library databases through 30 June 2018 was conducted. Pooled sensitivity, specificity, positive and negative likelihood ratios and diagnostic odds ratios of the ABVS and HHUS were calculated, and summary receiver operating characteristic (SROC) curves were drawn. A total of nine studies, including 1985 lesions (628 malignant and 1357 benign) from 1774 patients, were analyzed. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for ABVS were 90.8% (95% confidence interval: 88.3%-93.0%), 82.2% (80.0%-84.2%), 5.39 (4.26-6.80), 0.10 (0.06-0.15) and 61.68 (32.31-117.76); those for HHUS were 90.6% (88.1%-92.8%), 81.0% (78.8%-83.0%), 5.22 (3.14-8.67), 0.11 (0.08-0.17) and 52.60 (32.06-86.35), respectively. The areas under the SROC curves in the differentiation of benign and malignant breast lesions were 0.93 and 0.94 for ABVS and HHUS, respectively, which were not significantly different (p = 0.853). In conclusion, based on available evidence in the literature, ABVS the diagnostic performance of the ABVS is similar to that of HHUS in the differentiation of benign and malignant breast lesions.
Collapse
Affiliation(s)
- Liang Wang
- Department of Ultrasound, Chinese Academy of Medical Sciences, and Peking Union Medical College Hospital, Beijing, China
| | - Zhen-Hong Qi
- Department of Ultrasound, Chinese Academy of Medical Sciences, and Peking Union Medical College Hospital, Beijing, China.
| |
Collapse
|
25
|
Yun G, Kim SM, Yun BL, Ahn HS, Jang M. Reliability of automated versus handheld breast ultrasound examinations of suspicious breast masses. Ultrasonography 2018; 38:264-271. [PMID: 30999717 PMCID: PMC6595129 DOI: 10.14366/usg.18055] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 12/23/2018] [Indexed: 11/03/2022] Open
Abstract
PURPOSE The purpose of this study was to assess the reliability of automated breast ultrasound (ABUS) examinations of suspicious breast masses in comparison to handheld breast ultrasound (HHUS) with regard to Breast Imaging Reporting and Data System (BI-RADS) category assessment, and to investigate the factors affecting discrepancies in categorization. METHODS A total of 135 masses that were assessed as BI-RADS categories 4 and 5 on ABUS that underwent ultrasound (US)-guided core needle biopsy from May 2017 to December 2017 were included in this study. The BI-RADS categories were re-assessed using HHUS. Agreement of the BI-RADS categories was evaluated using kappa statistics, and the positive predictive value of each examination was calculated. Logistic regression analysis was performed to identify the mammography and US findings associated with discrepancies in the BI-RADS categorization. RESULTS The overall agreement between ABUS and HHUS in all cases was good (79.3%, kappa=0.61, P<0.001). Logistic regression analysis revealed that accompanying suspicious microcalcifications on mammography (odds ratio [OR], 4.63; 95% confidence interval [CI], 1.83 to 11.71; P=0.001) and an irregular shape on US (OR, 5.59; 95% CI, 1.43 to 21.83; P=0.013) were associated with discrepancies in the BI-RADS categorization. CONCLUSION The agreement between ABUS and HHUS examinations in the BI-RADS categorization of suspicious breast masses was good. The presence of suspicious microcalcifications on mammography and an irregular shape on US were factors associated with ABUS yielding a lower level of suspicion than HHUS in terms of the BI-RADS category assessment.
Collapse
Affiliation(s)
- Gabin Yun
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Sun Mi Kim
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Bo La Yun
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Hye Shin Ahn
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Mijung Jang
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| |
Collapse
|
26
|
Rella R, Belli P, Giuliani M, Bufi E, Carlino G, Rinaldi P, Manfredi R. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use. Acad Radiol 2018; 25:1457-1470. [PMID: 29555568 DOI: 10.1016/j.acra.2018.02.014] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 02/10/2018] [Accepted: 02/11/2018] [Indexed: 10/17/2022]
Abstract
Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research.
Collapse
|
27
|
Farrokh A, Erdönmez H, Schäfer F, Maass N. SOFIA: A Novel Automated Breast Ultrasound System Used on Patients in the Prone Position: A Pilot Study on Lesion Detection in Comparison to Handheld Grayscale Ultrasound. Geburtshilfe Frauenheilkd 2018; 78:499-505. [PMID: 29880985 PMCID: PMC5986565 DOI: 10.1055/a-0600-2279] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 03/31/2018] [Accepted: 04/01/2018] [Indexed: 12/12/2022] Open
Abstract
Introduction
Most of the currently available automated breast ultrasound systems require patients to be in the supine position. Previous data, however, show a high recall rate with this method due to artifacts. The novel automated breast ultrasound scanner SOFIA scans the breast with the patient in a prone position, resulting in even compression of breast tissue. We present our initial results with this examination method.
Material and Methods
63 patients were analyzed using a handheld B-mode ultrasound. In cases of BI-RADS 1, 2 or 5, a SOFIA scan was performed. Sensitivity, specificity and accuracy were calculated. Interobserver agreement was evaluated using Cohenʼs kappa. The duration of the scan was measured for both methods.
Results
No BI-RADS 5 lesion was missed with SOFIA. The SOFIA had an additional recall rate of 16.67% compared to B-mode ultrasound. The sensitivity, specificity and accuracy of SOFIA was 100, 83.33 and 88.89%, respectively. Cohenʼs kappa showed substantial agreement (κ = 0.769) between examiner 1 (B-mode) and examiner 2 (SOFIA). The mean scan duration for the B-mode system and the SOFIA system was 24.21 minutes and 12.94 minutes, respectively. In four cases, D-cup breasts were not scanned in their entirety.
Conclusion
No cancer was missed when SOFIA was used in this preselected study population. The scanning time was approximately half of that required for B-mode ultrasound. The additional unnecessary recall rate was 16.67%. Larger D cup-size breasts were difficult to position and resulted in an incomplete image in four cases.
Collapse
Affiliation(s)
- André Farrokh
- Universitätsklinik Schleswig-Holstein, Campus Kiel, Klinik für Gynäkologie und Geburtshilfe, Kiel, Germany
| | - Harika Erdönmez
- Klinikum Bremerhaven-Reinkenheide, Frauenklinik, Bremerhaven, Germany
| | - Fritz Schäfer
- Universitätsklinik Schleswig-Holstein, Campus Kiel, Mammazentrum, Klinik für Gynäkologie und Geburtshilfe und Klinik für Radiologie und Neuroradiologie, Kiel, Germany
| | - Nicolai Maass
- Universitätsklinik Schleswig-Holstein, Campus Kiel, Klinik für Gynäkologie und Geburtshilfe, Kiel, Germany
| |
Collapse
|
28
|
Butler RS. Invited Commentary: Handheld or Automated—Staying Focused on the Goals of Screening US, with Response from Drs van Zelst and Mann. Radiographics 2018; 38:683-687. [DOI: 10.1148/rg.2018180033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Reni Simov Butler
- Department of Diagnostic Radiology, Yale University School of Medicine New Haven, Connecticut
| |
Collapse
|
29
|
van Zelst JCM, Mann RM. Automated Three-dimensional Breast US for Screening: Technique, Artifacts, and Lesion Characterization. Radiographics 2018; 38:663-683. [DOI: 10.1148/rg.2018170162] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Jan C. M. van Zelst
- From the Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Internal Address 766, Geert Grooteplein Zuid 10, PO Box 9101, 6500HB Nijmegen, the Netherlands
| | - Ritse M. Mann
- From the Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Internal Address 766, Geert Grooteplein Zuid 10, PO Box 9101, 6500HB Nijmegen, the Netherlands
| |
Collapse
|
30
|
Durand MA, Hooley RJ. Implementation of Whole-Breast Screening Ultrasonography. Radiol Clin North Am 2017; 55:527-539. [DOI: 10.1016/j.rcl.2016.12.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
31
|
|
32
|
Arribas EM, Whitman GJ, De Bruhl N. Screening Breast Ultrasound: Where Are We Today? CURRENT BREAST CANCER REPORTS 2016. [DOI: 10.1007/s12609-016-0223-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
33
|
Kim Y, Kang BJ, Kim SH, Lee EJ. Prospective Study Comparing Two Second-Look Ultrasound Techniques: Handheld Ultrasound and an Automated Breast Volume Scanner. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:2103-2112. [PMID: 27503758 DOI: 10.7863/ultra.15.11076] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 01/24/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES The aim of this study was to compare the diagnostic performance of handheld ultrasound (US) and an automated breast volume scanner (ABVS) as second-look US techniques subsequent to preoperative breast magnetic resonance imaging (MRI). METHODS We prospectively enrolled patients with breast cancer who underwent handheld US and ABVS examinations as second-look US modalities for additional suspicious lesions found via preoperative breast MRI. We reviewed each second-look US modality independently and evaluated the detection rate of each modality. We then analyzed the correlation between the detection rate and the MRI factors (size, distance, and enhancement type). RESULTS From March to September 2014, both types of second-look US examinations were performed on 40 patients with breast cancer who had 76 additional suspicious lesions detected via preoperative breast MRI. The detection rate of the ABVS was higher than that of handheld US for the second-look examination (94.7% versus 86.8%; P< .05). Among the 76 total lesions, 7 were only identified by the ABVS, 1 was only found by handheld US, and 3 were not detected by either the ABVS or handheld US. When we analyzed the correlation between the detection rate and MRI factors, the only meaningful factor was the enhancement type. The ability to detect a nonmass lesion was lower than the ability to detect a mass-type lesion (P < 0.05) for both the ABVS and handheld US. CONCLUSIONS For a second-look US examination subsequent to preoperative breast MRI in patients with breast cancer, the ABVS is a more efficient modality than handheld US for preoperative evaluations. However, both techniques have limitations in detecting nonmass lesions.
Collapse
Affiliation(s)
- Yoonsoo Kim
- Department of Radiology, Seoul St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea
| | - Bong Joo Kang
- Department of Radiology, Seoul St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea
| | - Sung Hun Kim
- Department of Radiology, Seoul St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea
| | - Eun Jae Lee
- Department of Radiology, Seoul St Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea
| |
Collapse
|
34
|
Wilczek B, Wilczek HE, Rasouliyan L, Leifland K. Adding 3D automated breast ultrasound to mammography screening in women with heterogeneously and extremely dense breasts: Report from a hospital-based, high-volume, single-center breast cancer screening program. Eur J Radiol 2016; 85:1554-63. [DOI: 10.1016/j.ejrad.2016.06.004] [Citation(s) in RCA: 110] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 05/27/2016] [Accepted: 06/06/2016] [Indexed: 11/27/2022]
|
35
|
Eisenbrey JR, Dave JK, Forsberg F. Recent technological advancements in breast ultrasound. ULTRASONICS 2016; 70:183-190. [PMID: 27179143 DOI: 10.1016/j.ultras.2016.04.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 04/20/2016] [Accepted: 04/24/2016] [Indexed: 06/05/2023]
Abstract
Ultrasound is becoming increasingly common as an imaging tool for the detection and characterization of breast tumors. This paper provides an overview of recent technological advancements, especially those that may have an impact in clinical applications in the field of breast ultrasound in the near future. These advancements include close to 100% fractional bandwidth high frequency (5-18MHz) 2D and 3D arrays, automated breast imaging systems to minimize the operator dependence and advanced processing techniques, such as those used for detection of microcalcifications. In addition, elastography and contrast-enhanced ultrasound examinations that are expected to further enhance the clinical importance of ultrasound based breast tumor screening are briefly reviewed. These techniques have shown initial promise in clinical trials and may translate to more comprehensive clinical adoption in the future.
Collapse
Affiliation(s)
- John R Eisenbrey
- Thomas Jefferson University, Department of Radiology, Division of Ultrasound, 132 South 10th St., Philadelphia, PA 19107, United States.
| | - Jaydev K Dave
- Thomas Jefferson University, Department of Radiology, Division of Ultrasound, 132 South 10th St., Philadelphia, PA 19107, United States
| | - Flemming Forsberg
- Thomas Jefferson University, Department of Radiology, Division of Ultrasound, 132 South 10th St., Philadelphia, PA 19107, United States
| |
Collapse
|