1
|
Yazdanpanah-Ardakani K, Niroomand-Oscuii H, Sahebi-Kuzeh Kanan R, Shokri N. Optimization of a centrifugal blood pump designed using an industrial method through experimental and numerical study. Sci Rep 2024; 14:7443. [PMID: 38548818 DOI: 10.1038/s41598-024-57019-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 03/13/2024] [Indexed: 04/02/2024] Open
Abstract
With improved treatment of coronary artery disease, more patients are surviving until heart failure occurs. This leads to an increase in patients needing devices for struggling with heart failure. Ventricular assist devices are known as the mainstay of these devices. This study aimed to design a centrifugal pump as a ventricular assist device. In order to design the pump, firstly, the geometrical parameters of the pump, including the gap distance, blade height, and position of the outlet relative to the blade, were investigated. Finally, the selected configuration, which had all the appropriate characteristics, both hydraulically and physiologically, was used for the rest of the study. The study of the blade, as the main component in energy transfer to the blood, in a centrifugal pump, has been considered in the present study. In this regard, the point-to-point design method, which is used in industrial applications, was implemented. The designer chooses the relationship between the blade angles at each radius in the point-to-point method. The present study selected logarithmic and second-order relations for designing the blade's profile. In total, 58 blades were examined in this study, which differed regarding blade inlet and outlet angles and the relationship between angle and radial position. ANSYS CFX 17.0 software was utilized to simulate blades' performances, and a benchmark pump provided by the US Food and Drug Administration (FDA) was used to validate the numerical simulations. Then, the selected impeller from the numerical investigation was manufactured, and its performance was compared experimentally with the FDA benchmark pump. A hydraulic test rig was also developed for experimental studies. The results showed that among the blades designed in this study, the blade with an input angle of 45° and an output angle of 55°, which is designed to implement a logarithmic relationship, has the best performance. The selected impeller configuration can increase the total head (at least by 20%) at different flow rates compared to the FDA pump.
Collapse
Affiliation(s)
| | | | | | - Nasim Shokri
- Department of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran
| |
Collapse
|
2
|
Mehmood K, Lazoglu I, Küçükaksu DS. Acausal Modelling of Advanced-Stage Heart Failure and the Istanbul Heart Ventricular Assist Device Support with Patient Data. Cardiovasc Eng Technol 2023; 14:726-741. [PMID: 37723332 DOI: 10.1007/s13239-023-00683-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 09/05/2023] [Indexed: 09/20/2023]
Abstract
BACKGROUND In object-oriented or acausal modelling, components of the model can be connected topologically, following the inherent structure of the physical system, and system equations can be formulated automatically. This technique allows individuals without a mathematics background to develop knowledge-based models and facilitates collaboration in multidisciplinary fields like biomedical engineering. This study conducts a preclinical evaluation of a ventricular assist device (VAD) in assisting advanced-stage heart failure patients in an acausal modelling environment. METHODS A comprehensive object-oriented model of the cardiovascular system with a VAD is developed in MATLAB/SIMSCAPE, and its hemodynamic behaviour is studied. An analytically derived pump model is calibrated for the experimental prototype of the Istanbul Heart VAD. Hemodynamics are produced under healthy, diseased, and assisted conditions. The study features a comprehensive collection of advanced-stage heart failure patients' data from the literature to identify parameters for disease modelling and to validate the resulting hemodynamics. RESULTS Regurgitation, suction, and optimal speeds are identified, and trends in different hemodynamic parameters are observed for the simulated pathophysiological conditions. Using pertinent parameters in disease modelling allows for more accurate results compared to the traditional approach of arbitrary reduction in left ventricular contractility to model dilated cardiomyopathy. CONCLUSION The current research provides a comprehensive and validated framework for the preclinical evaluation of cardiac assist devices. Due to its object-oriented nature, the featured model is readily modifiable for other cardiovascular diseases for studying the effect of pump operating conditions on hemodynamics and vice versa in silico and hybrid mock circulatory loops. The work also provides a potential teaching tool for understanding the pathophysiology of heart failure, diagnosis rationale, and degree of assist requirements.
Collapse
Affiliation(s)
- Khunsha Mehmood
- Department of Mechanical Engineering, Koç University, 34450, Istanbul, Turkey
| | - Ismail Lazoglu
- Department of Mechanical Engineering, Koç University, 34450, Istanbul, Turkey.
| | - Deniz Süha Küçükaksu
- Cardiovascular Surgery Department, School of Medicine, Başkent University, 34662, Istanbul, Turkey
| |
Collapse
|
3
|
Hemodynamic Evaluation of a Centrifugal Left Atrial Decompression Pump for Heart Failure with Preserved Ejection Fraction. Bioengineering (Basel) 2023; 10:bioengineering10030366. [PMID: 36978757 PMCID: PMC10044772 DOI: 10.3390/bioengineering10030366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/08/2023] [Accepted: 03/12/2023] [Indexed: 03/19/2023] Open
Abstract
This article discusses a new continuous flow mini pump that has been developed to improve symptoms and prognosis in patients with Heart Failure with Preserved Ejection Fraction (HFpEF), for which there are currently no established treatments. The pump is designed to discharge a reduced percentage of blood volume from the left atrium to the subclavian artery, clamped at the bifurcation with the aortic arch. The overall specifications, design parameters, and hemodynamics of this new device are discussed, along with data from in vitro circulation loop tests and numerical simulations. The article also compares the results for two configurations of the pump with respect to key indicators of hemocompatibility used in blood pump development.
Collapse
|
4
|
Jing T, Sun H, Cheng J, Zhou L. Optimization of a Screw Centrifugal Blood Pump Based on Random Forest and Multi-Objective Gray Wolf Optimization Algorithm. MICROMACHINES 2023; 14:406. [PMID: 36838106 PMCID: PMC9962552 DOI: 10.3390/mi14020406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 01/31/2023] [Accepted: 02/04/2023] [Indexed: 06/18/2023]
Abstract
The centrifugal blood pump is a commonly used ventricular assist device. It can replace part of the heart function, pumping blood throughout the body in order to maintain normal function. However, the high shear stress caused by the impeller rotating at high speeds can lead to hemolysis and, as a consequence, to stroke and other syndromes. Therefore, reducing the hemolysis level while ensuring adequate pressure generation is key to the optimization of centrifugal blood pumps. In this study, a screw centrifugal blood pump was used as the research object. In addition, pressure generation and the hemolysis level were optimized simultaneously using a coupled algorithm composed of random forest (RF) and multi-objective gray wolf optimization (MOGWO). After verifying the prediction accuracy of the algorithm, three optimized models were selected and compared with the baseline model in terms of pressure cloud, 2D streamline, SSS distribution, HI distribution, and vortex distribution. Finally, via a comprehensive evaluation, the optimized model was selected as the final optimization design, in which the pressure generation increased by 24% and the hemolysis value decreased by 48%.
Collapse
Affiliation(s)
| | | | | | - Ling Zhou
- Correspondence: ; Tel.: +86-138-1547-7737
| |
Collapse
|
5
|
Li Y, Xi Y, Wang H, Sun A, Deng X, Chen Z, Fan Y. The impact of rotor configurations on hemodynamic features, hemocompatibility and dynamic balance of the centrifugal blood pump: A numerical study. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3671. [PMID: 36507614 DOI: 10.1002/cnm.3671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 09/11/2022] [Accepted: 12/04/2022] [Indexed: 06/17/2023]
Abstract
To investigate the effect of rotor design configuration on hemodynamic features, hemocompatibility and dynamic balance of blood pumps. Computational fluid dynamics was employed to investigate the effects of rotor type (closed impeller, semi-open impeller), clearance height and back vanes on blood pump performance. In particular, the Eulerian hemolysis model based on a power-law function and the Lagrangian thrombus model with integrated stress accumulation and residence time were applied to evaluate the hemocompatibility of the blood pump. This study shows that compared to the closed impeller, the semi-open impeller can improve hemolysis at a slight sacrifice in head pressure, but increase the risk of thrombogenic potential and disrupt rotor dynamic balance. For the semi-open impeller, the pressure head, hemolysis, and axial thrust of the blood pump decrease with increasing front clearance, and the risk of thrombosis increases first and then decreases with increasing front clearance. Variations in back clearance have little effect on pressure head, but larger on back clearance, worsens hemolysis, thrombogenic potential and rotor dynamic balance. The employment of back vanes has little effect on the pressure head. All back vanes configurations have an increased risk of hemolysis in the blood pump but are beneficial for the improvement of the rotor dynamic balance of the blood pump. Reasonable back vanes configuration (higher height, wider width, longer length and more number) decreases the flow separation, increases the velocity of blood in the back clearance, and reduces the risk of blood pooling and thrombosis. It was also found that hemolysis index (HI) was highly negatively correlated with pressure difference between the top and back clearances (r = -.87), and thrombogenic potential was positively correlated with pressure difference between the top and back clearances (r = .71). This study found that rotor type, clearance height, and back vanes significantly affect the hydraulic performance, hemocompatibility and rotor dynamic balance of centrifugal blood pumps through secondary flow. These parameters should be carefully selected when designing and optimizing centrifugal blood pumps for improving the blood pump clinical outcomes.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
6
|
Wu P. Recent advances in the application of computational fluid dynamics in the development of rotary blood pumps. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
|
7
|
Li C, Qiu H, Ma J, Wang Y. Numerical study on the performance of centrifugal blood pump with superhydrophobic surface. Int J Artif Organs 2022; 45:1028-1036. [PMID: 36028949 DOI: 10.1177/03913988221114156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
AIM In order to reduce the blood damage of an artificial heart pump and optimize its hydraulic performance, a centrifugal blood pump with superhydrophobic characteristics is proposed in this study. METHODS To study the influence of superhydrophobic surface characteristics on the performance of centrifugal blood pumps, the Navier slip model is used to simulate the slip characteristics of superhydrophobic surfaces, which is realized by the user defined function of ANSYS fluent. The user defined functions with different values of slip length are verified by two benchmark solutions of laminar flow and turbulence in the pipeline. The blood pump model adopts the designed centrifugal blood pump, and its head, hydraulic efficiency and hemolysis index are calculated. The Navier slip boundary condition (a constant slip-length of 50 μm) is applied to the walls of the blood pump impeller and a volute at different positions, and the influence of the superhydrophobic surface on the performance of the blood pump at the design point Q = 6 L/min was compared and analyzed. RESULTS The results show that the centrifugal blood pump model used in this paper has good blood compatibility and meets the design requirements; the superhydrophobic surface can significantly reduce the scalar shear stress in the blood pump. At the design point, when the slip length is 50 μm, the mass-average scalar shear stress in the impeller area and the volute area reduction rate is about 5.9%, the hydraulic efficiency growth rate is about 3.8%, the hemolysis index reduction rate is about 18.4%, and the pressure head changes little with a growth rate of 0.3%. CONCLUSIONS Centrifugal blood pumps with superhydrophobic surfaces can improve the efficiency of blood pumps and reduce hemolysis. Based on these encouraging results, vitro investigations for actual blood damage would be practicable.
Collapse
Affiliation(s)
- Chengcheng Li
- Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Huihe Qiu
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong
| | - Jianying Ma
- Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai, China
| | - Ying Wang
- Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China.,Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong
| |
Collapse
|
8
|
Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study. J Funct Biomater 2022; 13:jfb13010007. [PMID: 35076513 PMCID: PMC8788462 DOI: 10.3390/jfb13010007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/22/2021] [Accepted: 01/07/2022] [Indexed: 02/05/2023] Open
Abstract
Background: Currently, left ventricular assist devices (LVADs) are a successful surgical treatment for patients with end-stage heart failure on the waiting list or with contraindicated heart transplantation. In Russia, Sputnik 1 LVAD was also successfully introduced into clinical practice as a bridge-to-transplant and a destination therapy device. Development of Sputnik 2 LVAD was aimed at miniaturization to reduce invasiveness, optimize hemocompatibility, and improve versatility for patients of various sizes. Methods: We compared hemolysis level in flow path of the Sputnik LVADs and investigated design aspects influencing other types of blood damage, using predictions of computational fluid dynamics (CFD) and experimental assessment. The investigated operating point was a flow rate of 5 L/min and a pressure head of 100 mm Hg at an impeller rotational speed of 9100 min−1. Results: Mean hemolysis indices predicted with CFD were 0.0090% in the Sputnik 1 and 0.0023% in the Sputnik 2. Averaged values of normalized index of hemolysis obtained experimentally for the Sputnik 1 and the Sputnik 2 were 0.011 ± 0.003 g/100 L and 0.004 ± 0.002 g/100 L, respectively. Conclusions: Obtained results indicate obvious improvements in hemocompatibility and sufficiently satisfy the determined miniaturization aim for the Sputnik 2 LVAD development.
Collapse
|
9
|
Geometric Optimization of an Extracorporeal Centrifugal Blood Pump with an Unshrouded Impeller Concerning Both Hydraulic Performance and Shear Stress. Processes (Basel) 2021. [DOI: 10.3390/pr9071211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Centrifugal blood pumps have provided a powerful artificial support system for patients with vascular diseases. In the design process, geometrical optimization is usually needed to acquire a more biocompatible model for clinical uses. In the current paper, we propose a method for multi-objective optimization concerning both the hydraulic and the hemolytic performances of the pump based on the near-orthogonal array in which the traditional hemolysis index (HI) is replaced with the maximum scalar shear stress criteria to reduce the computation load. The method is demonstrated with the optimization of an extracorporeal centrifugal blood pump with an unshrouded impeller. CFD studies on the original and nine modified pump models are carried out. The calculated hydraulic performances of the optimized model are also compared against the experiments for validation of the numeric method, with an error of 3.6% at the original design point. The resulting blood pump with low maximum scalar shear stress (132.2 Pa) shows a low degree of calculated HI (1.69 × 10−3).
Collapse
|
10
|
Wu P, Huo J, Dai W, Wu WT, Yin C, Li S. On the Optimization of a Centrifugal Maglev Blood Pump Through Design Variations. Front Physiol 2021; 12:699891. [PMID: 34220556 PMCID: PMC8249853 DOI: 10.3389/fphys.2021.699891] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 05/25/2021] [Indexed: 11/13/2022] Open
Abstract
Centrifugal blood pumps are usually designed with secondary flow paths to avoid flow dead zones and reduce the risk of thrombosis. Due to the secondary flow path, the intensity of secondary flows and turbulence in centrifugal blood pumps is generally very high. Conventional design theory is no longer applicable to centrifugal blood pumps with a secondary flow path. Empirical relationships between design variables and performance metrics generally do not exist for this type of blood pump. To date, little scientific study has been published concerning optimization and experimental validation of centrifugal blood pumps with secondary flow paths. Moreover, current hemolysis models are inadequate in an accurate prediction of hemolysis in turbulence. The purpose of this study is to optimize the hydraulic and hemolytic performance of an inhouse centrifugal maglev blood pump with a secondary flow path through variation of major design variables, with a focus on bringing down intensity of turbulence and secondary flows. Starting from a baseline design, through changing design variables such as blade angles, blade thickness, and position of splitter blades. Turbulent intensities have been greatly reduced, the hydraulic and hemolytic performance of the pump model was considerably improved. Computational fluid dynamics (CFD) combined with hemolysis models were mainly used for the evaluation of pump performance. A hydraulic test was conducted to validate the CFD regarding the hydraulic performance. Collectively, these results shed light on the impact of major design variables on the performance of modern centrifugal blood pumps with a secondary flow path.
Collapse
Affiliation(s)
- Peng Wu
- Artificial Organ Technology Laboratory, School of Mechanical and Electric Engineering, Soochow University, Suzhou, China
| | - Jiadong Huo
- Artificial Organ Technology Laboratory, School of Mechanical and Electric Engineering, Soochow University, Suzhou, China
| | - Weifeng Dai
- Artificial Organ Technology Laboratory, School of Mechanical and Electric Engineering, Soochow University, Suzhou, China
| | - Wei-Tao Wu
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, China
| | - Chengke Yin
- Artificial Organ Technology Laboratory, School of Mechanical and Electric Engineering, Soochow University, Suzhou, China
| | - Shu Li
- Institute for Medical Device Control, National Institutes for Food and Drug Control, Beijing, China
| |
Collapse
|
11
|
YAZDANPANH-ARDAKANI KOHYAR, NIROOMAND-OSCUII HANIEH. COMPUTATIONAL STUDY ON THE PERFORMANCE OF A CENTRIFUGAL LVAD WITH THE IMPELLER DESIGNED BY INDUSTRIAL METHOD: PROPOSING SIMPLE-TO-MANUFACTURE LVAD’S IMPELLERS. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421500111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Although the demand of donor hearts for patients with end-stage heart failure is growing, its supply has remained constant. Ventricular assist devices (VADs) provide a chance of finding donor heart by increasing waiting period. In this study, the main goal is to employ an industrial method (point-by-point method) for designing blades profile with a simplified geometry which can be produced by conventional manufacturing methods. In this study, a centrifugal continuous-flow rotary pump is designed and the effects of components’ different geometries on the left ventricular assist devices (LVADs) function are investigated. Moreover, both hydraulic performance and blood damages (hemolysis index (HI)) caused by the pump are considered as design criteria. ANSYS CFX 17 is used to analyze the performance of the designed LVAD. Additionally, the geometry of components are investigated based on fulfilling the required performance of the LVAD while reducing the blood damage level. Comparing the designed VAD with the commercial ones shows that the designed blade further improves the performance of the centrifugal LVAD. Therefore, designing the impeller’s blade profile with point-by-point method seems to be promising. Simplicity in manufacturing is considered to be a big advantage for a design which also leads to lower manufacturing costs. This study demonstrates how industrial design methods can be employed to design simple-to-manufacture impellers which are suitable for LVADs.
Collapse
|
12
|
Aka IB, Ozturk C, Lazoglu I. Numerical investigation of volute tongue design on hemodynamic characteristics and hemolysis of the centrifugal blood pump. SN APPLIED SCIENCES 2021. [DOI: 10.1007/s42452-021-04142-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
AbstractIn the design of rotary blood pumps, the optimization of design parameters plays an essential role in enhancing the hydrodynamic performance and hemocompatibility. This study investigates the influence of the volute tongue angle as a volute geometric parameter on the hemodynamic characteristics of a blood pump. A numerical investigation on five different versions of volute designs is carried out by utilizing a computational fluid dynamics (CFD) software ANSYS-FLUENT. The effect of volute tongue angle is evaluated regarding the hydrodynamic performance, circumferential pressure distribution, the radial force, and the blood damage potential. A series of volute configurations are constructed with a fixed radial gap (5%), but varying tongue angles ranging from 10 to 50°. The relative hemolysis is assessed with the Eulerian based empirical power-law blood damage model. The pressure-flow rate characteristics of the volute designs at a range of rotational speeds are obtained from the experimental measurements by using the blood analog fluid. The results indicate an inverse relationship between hydraulic performance and the tongue angle; at higher tongue angles, a decrease in performance was observed. However, a higher tongue angle improves the net radial force acting on the impeller. The pump achieves the optimized performance at 20° of the tongue angle with the relatively high hydrodynamic performance and minor blood damage risk.
Collapse
|
13
|
Sarkisyan H, Stevens R, Tchantchaleishvili V, Rossano J, Throckmorton A. Integrated long-term multifunctional pediatric mechanical circulatory assist device. Artif Organs 2020; 45:E65-E78. [PMID: 33191508 DOI: 10.1111/aor.13863] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 10/11/2020] [Accepted: 11/03/2020] [Indexed: 11/27/2022]
Abstract
There continues to be limited, viable ventricular assist device technology options to support the dysfunctional states of pediatric heart failure. To address this need, we are developing a magnetically suspended, versatile pumping technology that uniquely integrates two blood pumps in a series configuration within a single device housing. This device enables operational switching from the usage of one pump to another as needed for clinical management or to support growth and development of the pediatric patient. Here, we present the initial design where we conducted a virtual fit study, the Taguchi Design Optimization Method, iterative design to develop pump geometries. Computational tools were used to estimate the pressure generation, capacity delivery, hydraulic efficiency, fluid stress levels, exposure time to stresses, blood damage index, and fluid forces on the impellers. Prototypes of the pumps were tested in a flow loop using a water-glycerin solution. Both designs demonstrated the capability to generate target pressures and flows. Blood damage estimations were below threshold levels and achieved design requirements; however, maximum scalar stress levels were above the target limit. Radial and axial forces were less than 1 N and 10 N, respectively. The performance data trends for physical prototypes correlated with theoretical expectations. The centrifugal prototype was able to generate slightly higher pressure rises than numerical predictions. In contrast, the axial prototype outperformed the computational studies. Experimental data were both repeatable and reproducible. The findings from this research are promising, and development will continue.
Collapse
Affiliation(s)
- Harutyun Sarkisyan
- BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Randy Stevens
- Pediatrics, College of Medicine, Drexel University, Philadelphia, PA, USA.,Heart Center for Children, St. Christopher's Hospital for Children, Philadelphia, PA, USA
| | | | - Joseph Rossano
- Division of Cardiology, Pediatric Heart Failure & Transplant Program, The Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Amy Throckmorton
- BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA
| |
Collapse
|
14
|
Cheng L, Tan J, Yun Z, Wang S, Yu Z. Analysis of flow field and hemolysis index in axial flow blood pump by computational fluid dynamics-discrete element method. Int J Artif Organs 2020; 44:46-54. [PMID: 32393086 DOI: 10.1177/0391398820917145] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
To fully study the relationship between the internal flow field and hemolysis index in an axial flow blood pump, a computational fluid dynamics-discrete element method coupled calculation method was used. Through numerical analysis under conditions of 6000, 8000, and 10,000 r/min, it was found that there was flow separation of blood cell particles in the tip of the impeller and the guide vane behind the impeller. The flow field has a larger pressure gradient distribution, which reduces the lift ratio of the blood pump and easily causes blood cell damage. The study shows that the hemolysis index obtained by the computational fluid dynamics-discrete element method is 4.75% higher than that from the traditional computational fluid dynamics method, which indicates the impact of microcollision between erythrocyte particles and walls on hemolysis index and also further verifies the validity of the computational fluid dynamics-discrete element coupling method. Through the hydraulic and particle image velocimetry experiments of the blood pump, the coincidence between numerical calculation and experiment is analyzed from macro and micro aspects, which shows that the numerical calculation method is feasible.
Collapse
Affiliation(s)
- Lizhi Cheng
- School of Mechanical and Electrical Engineering, Central South University, Changsha, China.,School of Mechanical and Electrical Engineering, Changsha University, Changsha, China
| | - Jianping Tan
- School of Mechanical and Electrical Engineering, Central South University, Changsha, China
| | - Zhong Yun
- School of Mechanical and Electrical Engineering, Central South University, Changsha, China
| | - Shuai Wang
- School of Mechanical and Electrical Engineering, Central South University, Changsha, China
| | - Zheqin Yu
- School of Mechanical and Electrical Engineering, Central South University, Changsha, China
| |
Collapse
|
15
|
Good BC, Manning KB. Computational modeling of the Food and Drug Administration's benchmark centrifugal blood pump. Artif Organs 2020; 44:E263-E276. [PMID: 31971269 DOI: 10.1111/aor.13643] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 01/06/2020] [Accepted: 01/08/2020] [Indexed: 12/13/2022]
Abstract
In order to simulate hemodynamics within centrifugal blood pumps and to predict pump hemolysis, CFD simulations must be thoroughly validated against experimental data. They must also account for and accurately model the specific working fluid in the pump, whether that is a blood-analog solution to match an experimental PIV study or animal blood in a hemolysis experiment. Therefore, the Food and Drug Administration (FDA) benchmark centrifugal blood pump and its database of experimental PIV and hemolysis data were used to thoroughly validate CFD simulations of the same blood pump. A Newtonian blood model was first used to compare to the PIV data with a blood analog fluid while hemolysis data were compared using a power-law hemolysis model fit to porcine blood data. A viscoelastic blood model was then incorporated into the CFD solver to investigate the importance of modeling blood's viscoelasticity in centrifugal pumps. The established computational framework, including a dynamic rotating mesh, animal blood-specific fluid properties and hemolysis modeling, and a k-ω SST turbulence model, was shown to more accurately predict pump pressure heads, velocity fields, and hemolysis compared to previously published CFD studies of the FDA centrifugal pump. The CFD simulations were able to match the FDA pressure and hemolysis data for multiple pump operating conditions, with the CFD results being within the standard deviations of the experimental results. While CFD radial velocity profiles between the impeller blades also compared well to the PIV velocity results, more work is still needed to address the large variability among both experimental and computational predictions of velocity in the diffuser outlet jet. Small differences were observed between the Newtonian and viscoelastic blood models in pressure head and hemolysis at the higher flow rate cases (FDA Conditions 4 and 5) but were more significant at lower flow rate and pump impeller speeds (FDA Condition 1). These results suggest that the importance of accounting for blood's viscoelasticity may be dependent on the specific blood pump operating conditions. This detailed computational framework with improved modeling techniques and an extensive validation procedure will be used in future CFD studies of centrifugal blood pumps to aid in device design and predictions of their biological responses.
Collapse
Affiliation(s)
- Bryan C Good
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, USA
| | - Keefe B Manning
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, USA.,Department of Surgery, Penn State Hershey Medical Center, Hershey, PA, USA
| |
Collapse
|