Hahne M, Crone V, Thomas I, Wolfgramm C, Liedtke FKP, Wurm FH, Torner B. Interaction of a Ventricular Assist Device With Patient-Specific Cardiovascular Systems: In-Silico Study With Bidirectional Coupling. ASAIO J 2024; 70:832-840. [PMID: 38551498 PMCID: PMC11426988 DOI: 10.1097/mat.0000000000002181] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2024] Open
Abstract
Ventricular assist devices (VADs) are used to assist the heart function of patients with advanced heart failure. Computational fluid dynamics in VADs are widely applied in the development and optimization, for example, to evaluate blood damage. For these simulations, the pulsating operating conditions, in which the VAD operates, should be included accurately. Therefore, this study aims to evaluate the flow in a VAD by interacting with patient-specific cardiovascular systems of heart failure patients. A numeric method will be presented, which includes a patient-specific cardiovascular system model that is bidirectionally coupled with a three-dimensional (3D) flow simulation of the HeartMate 3. The cardiovascular system is represented by a lumped parameter model. Three heart failure patients are considered, based on clinical data from end-stage heart failure patients. Various parameters of the cardiovascular system and the VAD are analyzed, for example, flow rates, pressures, VAD heads, and efficiencies. A further important parameter is the blood damage potential of the VAD, which varies significantly among different patients. Moreover, the predicted blood damage fluctuates within a single heartbeat. The increase in blood damage is evaluated based on the operating conditions. Both, overload and especially partial load conditions during the pulsating operation result in elevated blood damage.
Collapse
Affiliation(s)
- Mario Hahne
- From the Institute of Turbomachinery, University of Rostock, Rostock, Germany
| | - Vincenz Crone
- From the Institute of Turbomachinery, University of Rostock, Rostock, Germany
| | - Inga Thomas
- From the Institute of Turbomachinery, University of Rostock, Rostock, Germany
| | - Calvin Wolfgramm
- From the Institute of Turbomachinery, University of Rostock, Rostock, Germany
| | | | - Frank-Hendrik Wurm
- From the Institute of Turbomachinery, University of Rostock, Rostock, Germany
| | - Benjamin Torner
- From the Institute of Turbomachinery, University of Rostock, Rostock, Germany
| |
Collapse
|
2
|
Zhou M, Qi Z, Xia Z, Li Y, Ling W, Yang J, Yang Z, Pei J, Wu D, Huo W, Huang X. Miniaturized soft centrifugal pumps with magnetic levitation for fluid handling. SCIENCE ADVANCES 2021; 7:eabi7203. [PMID: 34705505 PMCID: PMC8550243 DOI: 10.1126/sciadv.abi7203] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Centrifugal pumps are essential mechanical components for liquid delivery in many biomedical systems whose miniaturization can promote innovative disease treatment approaches. However, centrifugal pumps are predominately constructed by rigid and bulky components. Here, we combine the soft materials and flexible electronics to achieve soft magnetic levitation micropumps (SMLMs) that are only 1.9 to 12.8 grams in weight. The SMLMs that rotate at a rotation speed of 1000 revolutions per min to pump liquids with various viscosities ranging from 1 to 6 centipoise can be used in assisting dialysis, blood circulation, and skin temperature control because of excellent biocompatibility with no organ damage. The development of SMLMs not only demonstrates the possibility to replace rigid rotating structures with soft materials for handling large volumes of fluids but also indicates the potential for fully flexible artificial organs that may revolutionize health care and improve the well-being of patients.
Collapse
Affiliation(s)
- Mingxing Zhou
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Zhijie Qi
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Zhiqiang Xia
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Ya Li
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Wei Ling
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Jingxuan Yang
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Zhen Yang
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Ji Pei
- National Research Center of Pumps, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China
| | - Dazhuan Wu
- College of Energy Engineering, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang 310027, China
| | - Wenxing Huo
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
- Corresponding author. (W.H.); (X.H.)
| | - Xian Huang
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China
- Corresponding author. (W.H.); (X.H.)
| |
Collapse
|