1
|
Wu P, Wu ZJ, Chen H, Chen Z, Zhang X, Yang M. Editorial: Recent advances in the design and preclinical evaluation of ventricular assist devices. Front Physiol 2023; 14:1322077. [PMID: 38028772 PMCID: PMC10680364 DOI: 10.3389/fphys.2023.1322077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Accepted: 10/16/2023] [Indexed: 12/01/2023] Open
Affiliation(s)
- Peng Wu
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, China
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Zhongjun J. Wu
- Department of Surgery, University of Maryland School of Medicine, Baltimore, MD, United States
| | - Haibo Chen
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiwen Zhang
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Ming Yang
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Jiang Q, Mei X, Huan N, Su W, Cheng L, He H, Zhang L. In vitro comparative study of red blood cell and VWF damage on 3D printing biomaterials under different blood-contacting conditions. Proc Inst Mech Eng H 2023; 237:1029-1036. [PMID: 37417741 DOI: 10.1177/09544119231186474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Mechanical circulatory support devices (MCSDs) are often associated with hemocompatible complications such as hemolysis and gastrointestinal bleeding when treating patients with end-stage heart failure. Shear stress and exposure time have been identified as the two most important mechanical factors causing blood damage. However, the materials of MCSDs may also induce blood damage when contacting with blood. In this study, the red blood cell and von Willebrand Factor (VWF) damage caused by four 3D printing biomaterials were investigated, including acrylic, PCISO, Somos EvoLVe 128, and stainless steel. A roller pump circulation experimental platform and a rotor blood-shearing experimental platform were constructed to mimic static and dynamic blood-contacting conditions of materials in MCSDs, respectively. Free hemoglobin assay and VWF molecular weight analysis were performed on the experimental blood samples. It indicated that different 3D printing materials and technology could induce different levels of damage to red blood cells and VWF, with acrylic causing the least damage under both static and dynamic conditions. In addition, it was found that blood damage measured for the same material differed on the two platforms. Therefore, a combination of static and dynamic experiments should be used to comprehensively investigate the effects of blood damage caused by the material. It can provide a reference for the design and evaluation of materials in different components of MCSDs.
Collapse
Affiliation(s)
- Qiubo Jiang
- Artificial Organ Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Xu Mei
- Artificial Organ Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Nana Huan
- Artificial Organ Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Wangwang Su
- Artificial Organ Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Longhui Cheng
- Artificial Organ Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Haidong He
- Robotics and Microsystems Center, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Liudi Zhang
- Artificial Organ Laboratory, Bio-manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, Jiangsu, China
| |
Collapse
|
3
|
Ahmad F, Cheema TA, Rehman K, Ullah M, Jamil M, Park CW. Hemodynamic performance evaluation of neonatal ECMO double lumen cannula using fluid-structure interaction. Int J Numer Method Biomed Eng 2023; 39:e3706. [PMID: 37039384 DOI: 10.1002/cnm.3706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 12/30/2022] [Accepted: 03/19/2023] [Indexed: 06/07/2023]
Abstract
Extra corporeal membrane oxygenation (ECMO) is an artificial oxygenation facility, employed in situations of cardio-pulmonary failure. Some diseases i.e., acute respiratory distress syndrome, pulmonary hypertension, corona virus disease (COVID-19) etc. affect oxygenation performance of the lungs thus requiring the need of artificial oxygenation. Critical care teams used ECMO technique during the COVID-19 pandemic to support the heart and lungs of COVID-19 patients who had an acute respiratory or cardiac failure. Double Lumen Cannula (DLC) is one of the most critical components of ECMO as it resides inside the patient and, connects patient with external oxygenation circuit. DLC facilitates delivery and drainage of blood from the patient's body. DLC is characterized by delicate balance of internal and external flows inside a limited space of the right atrium (RA). An optimal performance of the DLC necessitates structural stability under biological and hemodynamic loads, a fact that has been overlooked by previously published studies. In the past, many researchers experimentally and computationally investigated the hemodynamic performance of DLC by employing Eulerian approach, which evaluate instantaneous blood damage without considering blood shear exposure history (qualitative assessment only). The present study is an attempt to address the aforementioned limitations of the previous studies by employing Lagrangian (quantitative assessment) and incorporating the effect of fluid-structure interaction (FSI) to study the hemodynamic performance of neonatal DLC. The study was performed by solving three-dimensional continuity, momentum, and structural mechanics equation(s) by numerical methods for the blood flow through neonatal DLC. A two-way coupled FSI analysis was performed to analyze the effect of DLC structural deformation on its hemodynamic performance. Results show that the return lumen was the most critical section with maximum pressure drop, velocity, shear stresses, and blood damage. Recirculation and residence time of blood in the right atrium (RA) increases with increasing blood flow rates. Considering the structural deformation has led to higher blood damage inside the DLC-atrium system. Maximum Von-Mises stress was present on the side edges of the return lumen that showed direct proportionality with the blood flow rate.
Collapse
Affiliation(s)
- Faiq Ahmad
- Faculty of Mechanical Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Taqi Ahmad Cheema
- Faculty of Mechanical Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Khawar Rehman
- Department of Civil and Environmental Engineering, Hanyang University, Seoul, 04763, South Korea
- Department of Civil Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Minhaj Ullah
- Faculty of Mechanical Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Muhammad Jamil
- Analysis Group, Starfish Medical, 455 Boleskine Rd, Victoria, British Columbia, Canada
- Department of Mechanical Engineering, KoÇ University, Sariyar, Istanbul, 34450, Turkey
| | - Cheol Woo Park
- School of Mechanical Engineering, Kyungpook National University, 80 Daehak-Ro, Buk-Gu, Daegu, 41566, South Korea
| |
Collapse
|
4
|
Li P, Mei X, Ge W, Wu T, Zhong M, Huan N, Jiang Q, Hsu PL, Steinseifer U, Dong N, Zhang L. A comprehensive comparison of the in vitro hemocompatibility of extracorporeal centrifugal blood pumps. Front Physiol 2023; 14:1136545. [PMID: 37228828 PMCID: PMC10204736 DOI: 10.3389/fphys.2023.1136545] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 04/20/2023] [Indexed: 05/27/2023] Open
Abstract
Purpose: Blood damage has been associated with patients under temporary continuous-flow mechanical circulatory support. To evaluate the side effects caused by transit blood pumping, in vitro hemocompatibility testing for blood damage in pumps is considered a necessary reference before clinical trials. Methods: The hemocompatibility of five extracorporeal centrifugal blood pumps was investigated comprehensively, including four commercial pumps (the Abbott CentriMag, the Terumo Capiox, the Medos DP3, and the Medtronic BPX-80) and a pump in development (the magAssist MoyoAssist®). In vitro, hemolysis was tested with heparinized porcine blood at nominal operating conditions (5 L/min, 160 mmHg) and extreme operating conditions (1 L/min, 290 mmHg) using a circulation flow loop. Hematology analyses concerning the blood cell counts and the degradation of high-molecular-weight von Willebrand factor (VWF) during 6-h circulation were also evaluated. Results: Comparing the in vitro hemocompatibility of blood pumps at different operations, the blood damage was significantly more severe at extreme operating conditions than that at nominal operating conditions. The performance of the five blood pumps was arranged in different orders at these two operating conditions. The results also demonstrated superior hemocompatibility of CentriMag and MoyoAssist® at two operating conditions, with overall low blood damage at hemolysis level, blood cell counts, and degradation of high-molecular-weight VWF. It suggested that magnetic bearings have an advantage in hemocompatibility compared to the mechanical bearing of blood pumps. Conclusion: Involving multiple operating conditions of blood pumps in in vitro hemocompatibility evaluation will be helpful for clinical application. In addition, the magnetically levitated centrifugal blood pump MoyoAssist® shows great potential in the future as it demonstrated good in vitro hemocompatibility.
Collapse
Affiliation(s)
- Ping Li
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xu Mei
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Wanning Ge
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Tingting Wu
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Min Zhong
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Nana Huan
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Qiubo Jiang
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Po-Lin Hsu
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Nianguo Dong
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Liudi Zhang
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| |
Collapse
|
5
|
Krisher JA, Malinauskas RA, Day SW. The Effect of Blood Viscosity on Shear-Induced Hemolysis using a Magnetically Levitated Shearing Device. Artif Organs 2022; 46:1027-1039. [PMID: 35030287 DOI: 10.1111/aor.14172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 11/17/2021] [Accepted: 12/30/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Blood contacting medical devices, including rotary blood pumps, can cause shear-induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell-scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). METHODS We empirically investigated hemolysis in a magnetically levitated axial Couette flow device typical of a rotary VAD. The device is able to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Using this device, we explored the effects of both hematocrit and plasma viscosity on shear-induced hemolysis to characterize blood damage based on the viscosity-independent shear rate, rather than on shear stress. RESULTS Over a shear rate range of 20,000-80,000 1/s, the Index of Hemolysis (IH) was found to be dependent upon and well-predicted by shear rate alone. IH was independent of hematocrit, bulk viscosity, or the suspension media viscosity, and less correlated to shear stress (MSE=0.46-0.75) than to shear rate (MSE=0.06-0.09). CONCLUSION This study recommends that future investigations of shear-induced blood damage report findings with respect to the viscosity-neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.
Collapse
Affiliation(s)
- James A Krisher
- Kate Gleason College of Engineering, Rochester Institute of Technology
| | | | - Steven W Day
- Kate Gleason College of Engineering, Rochester Institute of Technology
| |
Collapse
|
6
|
Mei X, Lu B, Zhong M, Zhu Y, Zhang L, Ge W. The influence of surface roughness on the damage of von Willebrand Factor under shear flow condition. Int J Artif Organs 2021; 45:412-420. [PMID: 34736346 DOI: 10.1177/03913988211056961] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Despite technological advances in mechanical circulatory support devices to treat end-stage heart failure, blood damage induced by non-physiological shear stress in operation often triggered clinical hemocompatibility complications. The loss of high molecular weight von Willebrand Factor (HMW-VWF) has been considered as an essential cause of gastrointestinal bleeding. In addition to the mechanics factors, interface factors may also affect blood damage, especially the surface characteristics. In this study, the effect of surface roughness on VWF damage under flow condition was investigated. A roller pump circulation experimental platform with a roughness embedded sample chamber was constructed to provide blood shearing flow condition. VWF molecular weight analysis, VWF antigen (VWF-Ag) concentration assay, and VWF ristocetin cofactor activity (VWF-Rico) assay were performed on the sheared blood samples. These variables are the main functional indicators of VWF. It was found that the surface roughness induced VWF damage is mainly caused by the loss of HMW-VWF rather than reducing the total amount of VWF. The threshold value of surface roughness for a rapid increase in the degradation of HMW-VWF under low flow rate was obtained between Ra 0.4 and 0.6 μm, which was smaller than the threshold for hemolysis. Our findings indicated that VWF is more sensitive to the interface factor of surface roughness than red blood cells, thus has a higher requirement for blood pump design. It could provide reference for the material design and processing in developing mechanical circulatory support devices.
Collapse
Affiliation(s)
- Xu Mei
- Artificial Organ Laboratory, Bio-Manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Bin Lu
- Artificial Organ Laboratory, Bio-Manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Min Zhong
- Artificial Organ Laboratory, Bio-Manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Yuxin Zhu
- Artificial Organ Laboratory, Bio-Manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Liudi Zhang
- Artificial Organ Laboratory, Bio-Manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Wanning Ge
- Artificial Organ Laboratory, Bio-Manufacturing Research Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| |
Collapse
|
7
|
Kuck L, Simmonds MJ, Chan CHH, Pauls JP, Tansley GD, Feldmann F, McNamee AP. Ex vivo assessment of erythrocyte tolerance to the HeartWare ventricular assist device operated in three discrete configurations. Artif Organs 2020; 45:E146-E157. [PMID: 33236358 DOI: 10.1111/aor.13877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/11/2020] [Accepted: 11/18/2020] [Indexed: 12/13/2022]
Abstract
Despite technological advances in ventricular assist devices (VADs) to treat end-stage heart failure, hemocompatibility remains a constant concern, with supraphysiological shear stresses an unavoidable reality with clinical use. Given that impeller rotational speed is related to the instantaneous shear within the pump housing, it is plausible that the modulation of pump speed may regulate peak mechanical shear stresses and thus ameliorate blood damage. The present study investigated the hemocompatibility of the HeartWare HVAD in three configurations typical of clinical applications: standard systemic support left VAD (LVAD), pediatric support LVAD, and pulmonary support right VAD (RVAD) conditions. Two ex vivo mock circulation blood loops were constructed using explanted HVADs, in which pump speed and external loop resistance were manipulated to reflect the flow rates and differential pressures reported in configurations for standard adult LVAD (at 3150 rev⸱min-1 ), pediatric LVAD (at 2400 rev⸱min-1 ), and adult RVAD (at 1900 rev⸱min-1 ). Using bovine blood, the mock circulation blood loops were tested at 37°C over a period of 6 hours (consistent with ASTM F1841-97) and compared with static control. Hemocompatibility assessments were conducted for each test condition, examining hematology, hemolysis (absolute and normalized index), osmotic fragility, and blood viscosity. Regardless of configuration, continuous exposure of blood to the VAD over the 6-hour period significantly altered hematological and rheological blood parameters, and induced increased hemolysis when compared with a static control sample. Comparison of the three operational VAD configurations identified that the adult LVAD condition-associated with the highest pump speed, flow rate, and differential pressure across the pump-resulted in increased normalized hemolysis index (NIH; 0.07) when compared with the lower pump speed "off-label" counterparts (NIH of 0.04 in pediatric LVAD and 0.01 in adult RVAD configurations). After normalizing blood residence times between configurations, pump speed was identified as the primary determinant of accumulated blood damage; plausibly, blood damage could be limited by restricting pump speed to the minimum required to support matched cardiac output, but not beyond.
Collapse
Affiliation(s)
- Lennart Kuck
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Michael J Simmonds
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Chris Hoi Houng Chan
- School of Engineering and Built Environment, Griffith University, Southport, QLD, Australia.,Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, QLD, Australia
| | - Jo P Pauls
- School of Engineering and Built Environment, Griffith University, Southport, QLD, Australia.,Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, QLD, Australia
| | - Geoff D Tansley
- School of Engineering and Built Environment, Griffith University, Southport, QLD, Australia
| | - Friederike Feldmann
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Antony P McNamee
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| |
Collapse
|
8
|
Yu Z, Tan J, Wang S, Guo B. Structural improvement study of streamline design method, conical hub, and auxiliary blades for axial blood pump. Int J Artif Organs 2020; 44:251-261. [PMID: 32957840 DOI: 10.1177/0391398820959344] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The blood pump is a medical device used to assist or replace the diseased heart. Research on the structure of blood pumps has been committed to achieving better hemolysis and hydraulic performance. The purpose of this study was to find some effective ways to improve design methods and hydraulic structures. The research contents of improvement include: (1) improved blade streamline design method; (2) conical impeller hub; (3) additional auxiliary blades. Characteristic analysis and parameter design were carried out on the above three aspects. The methods used in this study included Dynamics (CFD) simulation, hydraulic experiments, and Particle Image Velocimetry (PIV) experiments. The results showed that this improved streamline design method could improve the distortion of blades and ensure a smaller impeller length. And, in the enhanced design of the hub, it is designed to be conical with inlet and outlet diameters of 7.5 and 12.8 mm, respectively. Furthermore, the auxiliary blades between the main blades are analyzed and designed. The results have the best performance optimization effect when the length of the auxiliary blades is 55% of the main blades. In general, the structural improvements in this study achieved the effect of improving hydraulic performance and avoiding increased hemolysis. These methods can be considered as an effective means of improving blood pump performance.
Collapse
Affiliation(s)
- Zheqin Yu
- College of Mechanical and Electrical Engineering, Central South University, Hunan, China
| | - Jianping Tan
- College of Mechanical and Electrical Engineering, Central South University, Hunan, China
| | - Shuai Wang
- College of Mechanical and Electrical Engineering, Central South University, Hunan, China
| | - Bin Guo
- School of Mechanical and Electrical Engineering, Jiangxi University of Science and Technology, Ganzhou, Jiangxi, China
| |
Collapse
|
9
|
Hatoum H, Maureira P, Dasi LP. A turbulence in vitro assessment of On-X and St Jude Medical prostheses. J Thorac Cardiovasc Surg 2019; 159:88-97. [PMID: 30905419 PMCID: PMC6703975 DOI: 10.1016/j.jtcvs.2019.02.046] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 01/17/2019] [Accepted: 02/09/2019] [Indexed: 02/08/2023]
Abstract
OBJECTIVE The objective of this study was to investigate and compare the hemodynamic and turbulence characteristics upon implantation of St Jude Medical (SJM) (St Jude Medical, St Paul, Minn) and On-X (On-X Life Technologies, Kennesaw, Ga) bileaflet mechanical valves. Both valves are considered highly successful bileaflet mechanical valves characterized by good clinical outcomes despite their numerous design differences. Although thromboembolism remains the main disadvantage of bileaflet mechanical valves, On-X valves have been shown to need less anticoagulation therapy. METHODS Hemodynamic assessment of a 23-mm On-X bileaflet mechanical valve and a 23-mm bileaflet SJM valve implanted in an aortic root was performed under pulsatile physiologic conditions. Time-resolved and phase-locked particle-image-velocimetry images and high-speed imaging data were acquired. Pressure gradients, effective orifice areas, dimensionless area index, leaflet position tracking, velocity, and principal Reynolds shear stress were calculated. RESULTS Pressure gradient for the On-X valve was 4.15 ± 0.099 mm Hg versus 4.75 ± 0.048 mm Hg for SJM (P < .001). Effective orifice area for the On-X valve was 2.61 ± 0.045 cm2 versus 2.36 ± 0.022 cm2 for SJM (P < .001). Area index was higher with SJM (0.87 ± 0.008) than with On-X (0.73 ± 0.013) (P < .001). On-X showed fluctuating leaflet behavior during systole, whereas SJM leaflets were stable. At peak systole, the maximal velocity with On-X was 1.86 m/s versus 2.33 m/s with SJM. Reynolds shear stress was higher with On-X compared with SJM at peak systole (95 vs 72 Pa). Higher velocity fluctuation was noted with the On-X valve. CONCLUSIONS This study shows that despite the design differences that characterize the On-X valve, the hemodynamic and turbulence parameters were not necessarily improved compared with SJM.
Collapse
Affiliation(s)
- Hoda Hatoum
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio
| | - Pablo Maureira
- Department of Cardiovascular Surgery, CHU de Nancy, Nancy, France
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio.
| |
Collapse
|
10
|
Khalili F, Gamage PPT, Sandler RH, Mansy HA. Adverse Hemodynamic Conditions Associated with Mechanical Heart Valve Leaflet Immobility. Bioengineering (Basel) 2018; 5:E74. [PMID: 30223603 DOI: 10.3390/bioengineering5030074] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 09/08/2018] [Accepted: 09/10/2018] [Indexed: 11/16/2022] Open
Abstract
Artificial heart valves may dysfunction, leading to thrombus and/or pannus formations. Computational fluid dynamics is a promising tool for improved understanding of heart valve hemodynamics that quantify detailed flow velocities and turbulent stresses to complement Doppler measurements. This combined information can assist in choosing optimal prosthesis for individual patients, aiding in the development of improved valve designs, and illuminating subtle changes to help guide more timely early intervention of valve dysfunction. In this computational study, flow characteristics around a bileaflet mechanical heart valve were investigated. The study focused on the hemodynamic effects of leaflet immobility, specifically, where one leaflet does not fully open. Results showed that leaflet immobility increased the principal turbulent stresses (up to 400%), and increased forces and moments on both leaflets (up to 600% and 4000%, respectively). These unfavorable conditions elevate the risk of blood cell damage and platelet activation, which are known to cascade to more severe leaflet dysfunction. Leaflet immobility appeared to cause maximal velocity within the lateral orifices. This points to the possible importance of measuring maximal velocity at the lateral orifices by Doppler ultrasound (in addition to the central orifice, which is current practice) to determine accurate pressure gradients as markers of valve dysfunction.
Collapse
|
11
|
Abstract
Red blood cells (RBC) can be damaged by medical products, from storage or from disease. Haemolysis (cell rupture and haemoglobin release) is often a key indicator, with mechanical fragility (MF) offering the potential to assess sub-haemolytic damage as well. This article reports on a unique approach to measuring haemolysis, without the need for centrifugation or other sample separation. It also reports on employing that in measuring blood fragility (susceptibility to haemolysis) under shear stress, utilising an electromagnet to cause a bead to oscillate within a cartridge that contains the sample. Cycling between stressing and optical measurement of induced haemolysis at progressively increasing durations of stress provides a fragility profile. Sub-system-level testing shows high accuracy for the haemolysis measurements and fair consistency for MF profiling. Improving accuracy and precision of profiling is a current focus and a fully integrated and automated version of this system is under development.
Collapse
Affiliation(s)
- Kenneth M Alfano
- a University of Michigan , Ann Arbor , MI , USA ;,b Blaze Medical Devices , Ann Arbor , MI , USA
| | | | | | | |
Collapse
|