1
|
Application of biomolecules modification strategies on PEEK and its composites for osteogenesis and antibacterial properties. Colloids Surf B Biointerfaces 2022; 215:112492. [PMID: 35430485 DOI: 10.1016/j.colsurfb.2022.112492] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 03/24/2022] [Accepted: 04/04/2022] [Indexed: 12/24/2022]
Abstract
As orthopedic and dental implants, polyetheretherketone (PEEK) is expected to be a common substitute material of titanium (Ti) and its alloys due to its good biocompatibility, chemical stability, and elastic modulus close to that of bone tissue. It could avoid metal allergy and bone resorption caused by the stress shielding effect of Ti implants, widely studied in the medical field. However, the lack of biological activity is not conducive to the clinical application of PEEK implants. Therefore, the surface modification of PEEK has increasingly become one of the research hotspots. Researchers have explored various biomolecules modification methods to effectively enhance the osteogenic and antibacterial activities of PEEK and its composites. Therefore, this review mainly summarizes the recent research of PEEK modified by biomolecules and discusses the further research directions to promote the clinical transformation of PEEK implants.
Collapse
|
2
|
Rodzeń K, McIvor MJ, Sharma PK, Acheson JG, McIlhagger A, Mokhtari M, McFerran A, Ward J, Meenan BJ, Boyd AR. The Surface Characterisation of Fused Filament Fabricated (FFF) 3D Printed PEEK/Hydroxyapatite Composites. Polymers (Basel) 2021; 13:3117. [PMID: 34578018 PMCID: PMC8471434 DOI: 10.3390/polym13183117] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/06/2021] [Accepted: 09/13/2021] [Indexed: 01/25/2023] Open
Abstract
Polyetheretherketone (PEEK) is a high-performance thermoplastic polymer which has found increasing application in orthopaedics and has shown a lot of promise for 'made-to-measure' implants via additive manufacturing approaches. However, PEEK is bioinert and needs to undergo surface modification to make it at least osteoconductive to ensure a more rapid, improved, and stable fixation that will last longer in vivo. One approach to solving this issue is to modify PEEK with bioactive agents such as hydroxyapatite (HA). The work reported in this study demonstrates the direct 3D printing of PEEK/HA composites of up to 30 weight percent (wt%) HA using a Fused Filament Fabrication (FFF) approach. The surface characteristics and in vitro properties of the composite materials were investigated. X-ray diffraction revealed the samples to be semi-crystalline in nature, with X-ray Photoelectron Spectroscopy and Time-of-Flight Secondary Ion Mass Spectrometry revealing HA materials were available in the uppermost surface of all the 3D printed samples. In vitro testing of the samples at 7 days demonstrated that the PEEK/HA composite surfaces supported the adherence and growth of viable U-2 OS osteoblast like cells. These results demonstrate that FFF can deliver bioactive HA on the surface of PEEK bio-composites in a one-step 3D printing process.
Collapse
Affiliation(s)
- Krzysztof Rodzeń
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Mary Josephine McIvor
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Preetam K. Sharma
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
- Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, UK
| | - Jonathan G. Acheson
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Alistair McIlhagger
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Mozaffar Mokhtari
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Aoife McFerran
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Joanna Ward
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Brian J. Meenan
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| | - Adrian R. Boyd
- School of Engineering, Ulster University, Shore Road, Newtownabbey BT37 0QB, UK; (M.J.M.); (P.K.S.); (J.G.A.); (A.M.); (M.M.); (A.M.); (J.W.); (B.J.M.)
| |
Collapse
|
3
|
Abd El-Fattah A, Youssef H, Gepreel MAH, Abbas R, Kandil S. Surface Morphology and Mechanical Properties of Polyether Ether Ketone (PEEK) Nanocomposites Reinforced by Nano-Sized Silica (SiO 2) for Prosthodontics and Restorative Dentistry. Polymers (Basel) 2021; 13:3006. [PMID: 34503046 PMCID: PMC8434100 DOI: 10.3390/polym13173006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 08/29/2021] [Accepted: 08/30/2021] [Indexed: 12/23/2022] Open
Abstract
In the field of orthopedics and traumatology, polyether ether ketone (PEEK) serves a significant role as a suitable alternative to traditional metal-based implants like titanium. PEEK is being used more commonly to replace traditional dental products. For bonding with various adhesive agents and preserved teeth, the surface alteration of PEEK was investigated. The aim of this research was to understand how different types and contents of nano-sized silica (SiO2) fillers influenced the surface and mechanical properties of PEEK nanocomposites used in prosthodontics. In this work, PEEK based nanocomposites containing hydrophilic or hydrophobic nano-silica were prepared by a compression molding technique. The influence of nano-SiO2 type and content (10, 20 and 30% wt) on surface properties of the resultant nanocomposites was investigated by the use of scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), surface roughness analysis, and contact angle measurement. The crystalline structures of PEEK/SiO2 nanocomposites were examined by X-ray diffraction (XRD) spectroscopy. Mechanical properties were measured by microhardness, elastic compression modulus, and flexural strength. All nanocomposites showed increased surface roughness compared to pure PEEK. SEM images revealed that nanocomposites filled with low content hydrophobic nano-SiO2 showed uniform dispersion within the PEEK matrix. The introduction of 10 wt% of hydrophobic nano-SiO2 to the PEEK matrix improved elastic modulus, flexural strength, and microhardness, according to the findings. The addition of nano-SiO2 fillers in a higher weight percentage, over 10%, significantly damages the mechanical characteristics of the resultant nanocomposite. On the basis of the obtained results, PEEK/SiO2 nanocomposites loaded with low content hydrophobic nano-SiO2 are recommended as promising candidates for orthopedic and prosthodontics materials.
Collapse
Affiliation(s)
- Ahmed Abd El-Fattah
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt; (R.A.); (S.K.)
- Department of Chemistry, College of Science, University of Bahrain, Sakhir P.O. Box 32038, Bahrain
| | - Heba Youssef
- College of Dentistry, Arab Academy for Science, Technology and Maritime Transport (AASTMT), El-Alamein 51718, Egypt;
| | - Mohamed Abdel Hady Gepreel
- Department of Materials Science and Engineering, Egypt-Japan University of Science and Technology (E-JUST), New Borg El-Arab City 21934, Egypt;
| | - Rafik Abbas
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt; (R.A.); (S.K.)
| | - Sherif Kandil
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt; (R.A.); (S.K.)
| |
Collapse
|
4
|
Li S, Wang T, Hu J, Li Z, Wang B, Wang L, Zhou Z. Surface porous poly-ether-ether-ketone based on three-dimensional printing for load-bearing orthopedic implant. J Mech Behav Biomed Mater 2021; 120:104561. [PMID: 33965810 DOI: 10.1016/j.jmbbm.2021.104561] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 04/16/2021] [Accepted: 04/19/2021] [Indexed: 02/07/2023]
Abstract
Poly-ether-ether-ketone (PEEK) possesses excellent biocompatibility and similar elastic modulus as bones but yet suffers from poor osseointegration. In order to balance PEEK's mechanical and osseointegration properties, a novel surface porous PEEK (SP-PEEK) is successfully fabricated by fused deposition modelling three-dimensional printing (FDM 3DP) and characterized by mechanical and osteogenesis in vitro tests. Moreover, the effects of pore diameter and pore layer number on the mechanical behaviors of SP-PEEK are investigated by theoretical model and numerical simulation. Comparison among experimental, theoretical and simulation results show good agreement. As pore diameter decreases, the equivalent strength and modulus become more sensitive to the decrease of pore layer number. In addition, the SP-PEEK exhibits the mechanical properties within the range of human trabecular bone and cortical bone, and thus can be tailored to mimic human bone by adjusting the pore diameter and pore layer number, which is benefit to mitigate stress shielding. The effects of pore diameter on the cell proliferation and osteogenic differentiation of SP-PEEK are tested by the co-culture of osteoblast precursor cells (MC3T3-E1) and SP-PEEK round discs. Results showcase that porous surface improves the osteogenesis in vitro, and the SP-PEEK group that the pore diameter is 0.6 mm exhibits optimal-performance osteogenesis in vitro.
Collapse
Affiliation(s)
- Shuai Li
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150080, China
| | - Tianyu Wang
- Department of Orthopedics, First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Jiqiang Hu
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150080, China
| | - Zhibin Li
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150080, China
| | - Bing Wang
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150080, China.
| | - Lianchao Wang
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150080, China
| | - Zhengong Zhou
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150080, China
| |
Collapse
|
5
|
Ma H, Suonan A, Zhou J, Yuan Q, Liu L, Zhao X, Lou X, Yang C, Li D, Zhang YG. PEEK (Polyether-ether-ketone) and its composite materials in orthopedic implantation. ARAB J CHEM 2021. [DOI: 10.1016/j.arabjc.2020.102977] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|
6
|
Hu J, Zhang R, Chen H, Wu Y, Chen L, Zhang Q, Ren H, Yan Y. The study on calcium polyphosphate/poly-amino acid composite for supportive bone substitute materials in vitro. NEW J CHEM 2021. [DOI: 10.1039/d0nj06128j] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A poly-amino acid/calcium polyphosphate composite with high mechanical strength, excellent stability and biological activity was prepared and studied for bone-repaired.
Collapse
Affiliation(s)
- Jinbo Hu
- School of Chemical Engineering
- Sichuan University
- Chengdu
- China
| | - Rongguang Zhang
- School of Chemical Engineering
- Sichuan University
- Chengdu
- China
| | - Hong Chen
- College of Physics
- Sichuan University
- Chengdu 610065
- China
| | - Yanan Wu
- College of Physics
- Sichuan University
- Chengdu 610065
- China
| | - Lichao Chen
- School of Chemical Engineering
- Sichuan University
- Chengdu
- China
| | - Qiyi Zhang
- School of Chemical Engineering
- Sichuan University
- Chengdu
- China
| | - Haohao Ren
- College of Physics
- Sichuan University
- Chengdu 610065
- China
| | - Yonggang Yan
- College of Physics
- Sichuan University
- Chengdu 610065
- China
| |
Collapse
|
7
|
Bhaduri SB, Sikder P. Biomaterials for Dental Applications. Biomed Mater 2021. [DOI: 10.1007/978-3-030-49206-9_14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
8
|
Yu Y, Xie K, Xie L, Deng Y. Endowing polyetheretherketone with anti-inflammatory ability and improved osteogenic ability. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2020; 32:42-59. [PMID: 32847454 DOI: 10.1080/09205063.2020.1815634] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Both osteogenesis and anti-inflammatory bioactive materials play a vital role in the regeneration of skeletal defects. Bone inflammation is hard to cure and can lead to malformation or amputation. The purpose of this study is to use anti-inflammatory drugs to endow polyetheretherketone (PEEK) with the dual ability to achieve anti-inflammatory effects while maintaining favorable biocompatibility. In this experiment, the porous PEEK was immersed in an aspirin (ASP) solution after sulfonation, and the obtained porous PEEK had significantly improved the anti-inflammatory abilities. Additionally, grafting the bone forming peptide (BFP) onto the porous PEEK can distinctly enchance the osteogenesis capability. The effects of the BFP polypeptide on the proliferation of MC3T3-E1 cells and ALP activity, and the effects of aspirin on inflammation were systematically investigated. The modified material showed favorable biocompatibility and osteogenic ability. The results suggest that the combination of the BFP polypeptide with aspirin may lead to a synergetic effect on the stimulation of osteogenesis and on the reduction of inflammation.
Collapse
Affiliation(s)
- Yue Yu
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Kenan Xie
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Lu Xie
- State Key Laboratory of Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Yi Deng
- School of Chemical Engineering, Sichuan University, Chengdu, China.,State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China.,Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
9
|
Knaus J, Schaffarczyk D, Cölfen H. On the Future Design of Bio-Inspired Polyetheretherketone Dental Implants. Macromol Biosci 2019; 20:e1900239. [PMID: 31802617 DOI: 10.1002/mabi.201900239] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2019] [Revised: 10/10/2019] [Indexed: 11/09/2022]
Abstract
Polyetheretherketone (PEEK) is a promising implant material because of its excellent mechanical characteristics. Although this polymer is a standard material in spinal applications, PEEK is not in use in the manufacturing of dental implants, where titanium is still the most-used material. This may be caused by its relative bio-inertness. By the use of various surface modification techniques, efforts have been made to enhance its osseointegrative characteristics to enable the polymer to be used in dentistry. In this feature paper, the state-of-the-art for dental implants is given and different surface modification techniques of PEEK are discussed. The focus will lie on a covalently attached surface layer mimicking natural bone. The usage of such covalently anchored biomimetic composite materials combines many advantageous properties: A biocompatible organic matrix and a mineral component provide the cells with a surrounding close to natural bone. Bone-related cells may not recognize the implant as a foreign body and therefore, may heal and integrate faster and more firmly. Because neither metal-based nor ceramics are ideal material candidates for a dental implant, the combination of PEEK and a covalently anchored mineralized biopolymer layer may be the start of the desired evolution in dental surgery.
Collapse
Affiliation(s)
- Jennifer Knaus
- Department of Chemistry, Physical Chemistry, University of Konstanz, Universitätsstraße 10, 78457, Konstanz, Germany.,stimOS GmbH, Byk-Gulden-Straße 2, 78467, Konstanz, Germany
| | | | - Helmut Cölfen
- Department of Chemistry, Physical Chemistry, University of Konstanz, Universitätsstraße 10, 78457, Konstanz, Germany
| |
Collapse
|
10
|
Jung HD, Jang TS, Lee JE, Park SJ, Son Y, Park SH. Enhanced bioactivity of titanium-coated polyetheretherketone implants created by a high-temperature 3D printing process. Biofabrication 2019; 11:045014. [PMID: 31365916 DOI: 10.1088/1758-5090/ab376b] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Polyetheretherketone (PEEK), one of the potential alternatives to metallic materials for implants, necessarily involves high temperature process conditions to be three-dimensionally (3D) printed. We developed a 3D printing setup equipped with thermally stabilized modules of the printing nozzle and building chamber, by which the PEEK implants could be successfully manufactured. Under optimized printing conditions, the maximal mechanical strength of the 3D printed sample attained over 80% of the original bulk property of PEEK. To enhance the interfacial biocompatibility, the as-printed implants were postprocessed with titanium (Ti) sputtering. The Ti-coated surfaces were evaluated through characterization studies of x-ray diffraction spectra, microscopic topographies, and wetting properties. For the in vitro tests, preosteoblasts were cultured on the developed PEEK-Ti structures and evaluated in terms of cell adhesion, proliferation, and osteogenic differentiation. In addition, the bone regeneration capability of the PEEK-Ti implants was confirmed by animal experiments using a rabbit tibia defect model for a period of 12 weeks. In the overall in vitro and in vivo tests, we confirmed the superior bioactivities of the Ti-modified and 3D printed interface by comparisons between the samples of machined and printed samples with or without Ti coating. Taken together, the comprehensive manufacturing approaches that involve 3D printing and biocompatible postprocessing are expected to have universal applicability in a wide range of bone tissue engineering.
Collapse
Affiliation(s)
- Hyun-Do Jung
- Research Institute of Advanced Manufacturing Technology, Korea Institute of Industrial Technology, Incheon 21999, Republic of Korea
| | | | | | | | | | | |
Collapse
|
11
|
He X, Deng Y, Yu Y, Lyu H, Liao L. Drug-loaded/grafted peptide-modified porous PEEK to promote bone tissue repair and eliminate bacteria. Colloids Surf B Biointerfaces 2019; 181:767-777. [PMID: 31234064 DOI: 10.1016/j.colsurfb.2019.06.038] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 06/16/2019] [Accepted: 06/17/2019] [Indexed: 02/07/2023]
Abstract
Bone restoration and related infection in bone defect repair remain thorny problems in clinical practice. Herein, a drug-loaded (chlorogenic acid, CGA)/grafted peptide (BFP) hydrogel system supported on a sulfonated polyetheretherketone (SPEEK) surface is constructed to address the problem of large-scale defects and related infections in clinical bone implantation. Briefly, the encapsulated chlorogenic acid is released during hydrogel degradation and can inhibit the growth of bacteria and provide a bacteria-free environment for new bone formation. In vitro experiments and cell adhesion/proliferation evaluation reveal that the chlorogenic acid-sodium alginate-peptide bridging system shows better bioaffinity than the control groups due to the BFP peptide on the surface of the hydrogel. In addition, bacterial experiments suggest that the released chlorogenic acid has excellent antibacterial activity against gram-negative and gram-positive bacteria. Therefore, the hydrogel bridging system has a prospective application in clinical applications for bone repair.
Collapse
Affiliation(s)
- Xianhua He
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China
| | - Yi Deng
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China; Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, SAR, China.
| | - Yue Yu
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China
| | - Hao Lyu
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China
| | - Li Liao
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China.
| |
Collapse
|
12
|
Masamoto K, Fujibayashi S, Yabutsuka T, Hiruta T, Otsuki B, Okuzu Y, Goto K, Shimizu T, Shimizu Y, Ishizaki C, Fukushima K, Kawai T, Hayashi M, Morizane K, Kawata T, Imamura M, Matsuda S. In vivo and in vitro bioactivity of a "precursor of apatite" treatment on polyetheretherketone. Acta Biomater 2019; 91:48-59. [PMID: 31009758 DOI: 10.1016/j.actbio.2019.04.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 03/20/2019] [Accepted: 04/17/2019] [Indexed: 01/01/2023]
Abstract
We recently developed a surface treatment, "precursor of apatite" (PrA), for polyetheretherketone (PrA-PEEK) via a simple, low-temperature process aiming to achieve stronger and faster adhesion to bone. The treatment involves three steps: H2SO4 immersion, exposure to O2 plasma discharge, and alkaline simulated body fluid (alkaline SBF) treatment. This method produces homogeneous fine particles of amorphous calcium phosphate on the PEEK, and we confirmed that PrA-PEEK had excellent apatite formation ability in an SBF immersion test. In the present study using PEEK implants in rabbit tibia, mechanical tests, and histological and radiological analyses revealed that PrA provided the PEEK substrate with excellent bone-bonding properties and osteo-conductivity at early stages (4 and 8 weeks), extending to 16 weeks. In vitro study using MC3T3-E1 cells revealed via XTT assay that PrA on the PEEK substrate resulted in no cytotoxicity, though PrA treatment seemed to suppress gene expression of integrin β-1 and Alp after 7-day incubation as shown by real-time PCR. On the whole, PrA treatment succeeded in giving in vivo bone-bonding properties to the PEEK substrate, and the treatment is a safe and promising method that can be applied in clinical settings. There was an inconsistency between in vivo and in vitro bioactivity, and this discrepancy indicated that apatite formation does not always need activation of osteoblasts at very early stage and that optimal conditions at cell and organism level may be different. STATEMENT OF SIGNIFICANCE: Polyetheretherketone (PEEK) is an attractive engineering polymer used for spine and dental surgery. To further improve clinical outcome of PEEK-based materials, we developed "Precursor of apatite" (PrA) treatment on the PEEK surface to confer bone-bonding properties. The advantages of this treatment are that it does not require high-temperature processing or special chemicals, and it is inexpensive. The present study clarified excellent in vivo bone-bonding property of PrA treatment. In addition, the results revealed important insights indicating that optimal conditions, especially wettability and crystallinity in calcium phosphate, differ at cell and organism levels. Moreover, our results indicated that prediction of in vivo bioactivity should be done in combination with multiple in vitro tests.
Collapse
|
13
|
Rehman M, Madni A, Webster TJ. The era of biofunctional biomaterials in orthopedics: what does the future hold? Expert Rev Med Devices 2018; 15:193-204. [DOI: 10.1080/17434440.2018.1430569] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Mubashar Rehman
- Department of Chemical Engineering, Northeastern University, Boston, MA, USA
- Department of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, Pakistan
- Nanobiotechnology Group, National Institute of Biotechnology and Genetic Engineering, Faisalabad, Pakistan
| | - Asadullah Madni
- Department of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, Pakistan
- Nanobiotechnology Group, National Institute of Biotechnology and Genetic Engineering, Faisalabad, Pakistan
| | - Thomas J. Webster
- Department of Chemical Engineering, Northeastern University, Boston, MA, USA
| |
Collapse
|
14
|
Yabutsuka T, Fukushima K, Hiruta T, Takai S, Yao T. Effect of pores formation process and oxygen plasma treatment to hydroxyapatite formation on bioactive PEEK prepared by incorporation of precursor of apatite. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 81:349-358. [DOI: 10.1016/j.msec.2017.07.017] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Revised: 06/08/2017] [Accepted: 07/13/2017] [Indexed: 11/28/2022]
|
15
|
Yabutsuka T, Fukushima K, Hiruta T, Takai S, Yao T. Fabrication of Bioactive Fiber-reinforced PEEK and MXD6 by Incorporation of Precursor of Apatite. J Biomed Mater Res B Appl Biomater 2017; 106:2254-2265. [DOI: 10.1002/jbm.b.34025] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 09/21/2017] [Accepted: 10/02/2017] [Indexed: 11/05/2022]
Affiliation(s)
- Takeshi Yabutsuka
- Department of Fundamental Energy Science, Graduate School of Energy Science; Kyoto University, Yoshida-Honmachi; Sakyo-ku Kyoto 606-8501 Japan
| | - Keito Fukushima
- Department of Fundamental Energy Science, Graduate School of Energy Science; Kyoto University, Yoshida-Honmachi; Sakyo-ku Kyoto 606-8501 Japan
| | - Tomoko Hiruta
- Department of Fundamental Energy Science, Graduate School of Energy Science; Kyoto University, Yoshida-Honmachi; Sakyo-ku Kyoto 606-8501 Japan
| | - Shigeomi Takai
- Department of Fundamental Energy Science, Graduate School of Energy Science; Kyoto University, Yoshida-Honmachi; Sakyo-ku Kyoto 606-8501 Japan
| | - Takeshi Yao
- National Institute of Technology, Kagawa College, 355, Chokushi-cho; Takamatsu Kagawa 761-8058 Japan
| |
Collapse
|
16
|
Deng L, Deng Y, Xie K. AgNPs-decorated 3D printed PEEK implant for infection control and bone repair. Colloids Surf B Biointerfaces 2017; 160:483-492. [PMID: 28992487 DOI: 10.1016/j.colsurfb.2017.09.061] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 09/17/2017] [Accepted: 09/29/2017] [Indexed: 10/18/2022]
Abstract
Polyetheretherketone (PEEK) is an ideal substitute material for bone tissue engineering, which can avoid the stress shielding phenomenon due to its similar mechanical properties to natural human bone. Complex bone defect and postoperative infection are still two enormous challenges in orthopedic clinics. It's well-known that additive manufacturing possesses the merits of high-precision and rapid prototyping, thus it easily meets the needs of mold processing. In the present study, we developed a novel Ag-decorated 3D printed PEEK via catecholamine chemistry. SEM image showed that silver nanoparticles (AgNPs) were evenly anchored on the surface. The following antibacterial tests, including bacterial inhibition ring, bacterial dynamics curves and antibiofilm test, indicated that the Ag-decorated 3D PEEK scaffolds displayed significant antibacterial effect towards Gram-negative and Gram-positive bacteria. Then MG-63 cells were seeded on samples for cell proliferation and ALP activity tests. The results demonstrated the scaffold modified with AgNPs could support cell proliferation, and enhanced higher alkaline phosphatase activity compared with pure PEEK scaffold. Expectedly, this dual functional 3D material holds great potential application in clinical bone tissue repair.
Collapse
Affiliation(s)
- Lijun Deng
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China
| | - Yi Deng
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China.
| | - Kenan Xie
- School of Chemical Engineering, Sichuan University, Chengdu, 610065, China
| |
Collapse
|
17
|
Monich PR, Berti FV, Porto LM, Henriques B, Novaes de Oliveira AP, Fredel MC, Souza JCM. Physicochemical and biological assessment of PEEK composites embedding natural amorphous silica fibers for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017. [PMID: 28629028 DOI: 10.1016/j.msec.2017.05.031] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
The main aim of this study was to assess the physicochemical and biological properties of a novel poly(ether ether ketone) (PEEK) composite containing 30%wt natural amorphous silica fibers (NASF). PEEK and NASF powders were previously functionalized by atomization and citric acid in order to enhance adhesion between polymeric matrix and fillers. Then, composites were produced by cold compression molding technique at 350°C for 3h. Materials were characterized by chemical, microstructural, thermophysical, mechanical and cytotoxic analysis. The results of the mechanical assays showed that the incorporation fibers increased the elastic modulus of the resultant PEEK composite in 56% while its microhardness increased in 26.7%. Chemical and microscopic analyses detected a good interfacial adhesion between PEEK and NASF. The results of the cytotoxicity assays indicated that PEEK/NASF composites stimulated the metabolic activity of fibroblasts and therefore a high cytocompatibility was noticed. PEEK composites embedding natural amorphous silica fibers revealed a high potential to be used in medicine and dentistry replacing several polymeric and composite materials.
Collapse
Affiliation(s)
- Patrícia R Monich
- Ceramic and Composite Materials Research Laboratories (CERMAT), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil
| | - Fernanda V Berti
- Integrated Technologies Laboratory (InteLAB), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil
| | - Luismar M Porto
- Integrated Technologies Laboratory (InteLAB), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil
| | - Bruno Henriques
- Ceramic and Composite Materials Research Laboratories (CERMAT), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil; Centre Microelectromechanical Systems (CMEMS), University of Minho, Guimarães 4800-058, Portugal
| | - Antonio P Novaes de Oliveira
- Laboratory of Glass-Ceramic Materials (VITROCER), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil
| | - Márcio C Fredel
- Ceramic and Composite Materials Research Laboratories (CERMAT), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil
| | - Júlio C M Souza
- Ceramic and Composite Materials Research Laboratories (CERMAT), Federal University of Santa Catarina (UFSC), Florianópolis/SC 88040-900, Brazil; Centre Microelectromechanical Systems (CMEMS), University of Minho, Guimarães 4800-058, Portugal; Center for Research on Dental Implants (CEPID), Postgraduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), 88040-900, Florianópolis/SC, Brazil.
| |
Collapse
|
18
|
Miyazaki T, Matsunami C, Shirosaki Y. Bioactive carbon–PEEK composites prepared by chemical surface treatment. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 70:71-75. [DOI: 10.1016/j.msec.2016.08.058] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Revised: 08/03/2016] [Accepted: 08/22/2016] [Indexed: 10/21/2022]
|
19
|
Ma R, Yu Z, Tang S, Pan Y, Wei J, Tang T. Osseointegration of nanohydroxyapatite- or nano-calcium silicate-incorporated polyetheretherketone bioactive composites in vivo. Int J Nanomedicine 2016; 11:6023-6033. [PMID: 27881916 PMCID: PMC5115692 DOI: 10.2147/ijn.s115286] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Polyetheretherketone (PEEK) exhibits appropriate biomechanical strength as well as good biocompatibility and stable chemical properties but lacks bioactivity and cannot achieve highly efficient osseointegration after implantation. Incorporating bioceramics into the PEEK matrix is a feasible approach for improving its bioactivity. In this study, nanohydroxyapatite (n-HA) and nano-calcium silicate (n-CS) were separately incorporated into PEEK to prepare n-HA/PEEK and n-CS/PEEK biocomposites, respectively, using a compounding and injection-molding technique, and the in vitro degradation characteristics were evaluated. Discs with a diameter of 8 mm were inserted in 8 mm full-thickness cranial defects in rabbits for 4 and 8 weeks, and implantation of pure PEEK was used as the control. Three-dimensional microcomputed tomography, histological analysis, fluorescence microscopy of new bone formation, and scanning electron microscopy were used to evaluate the osseointegration performance at the bone/implant interface. The results of the in vitro degradation study demonstrated that degradation of n-CS on the surface of n-CS/PEEK could release Ca and Si ions and form a porous structure. In vivo tests revealed that both n-CS/PEEK and n-HA/PEEK promoted osseointegration at the bone/implant interface compared to PEEK, and n-CS/PEEK exhibited higher bone contact ratio and more new bone formation compared with those of n-HA/PEEK, implying that n-CS/PEEK possessed a stronger ability to promote osseointegration. These two PEEK biocomposites are promising materials for the preparation of orthopedic or craniofacial implants.
Collapse
Affiliation(s)
- Rui Ma
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China; Department of Orthopedic Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shanxi Province, People's Republic of China
| | - Zhifeng Yu
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Songchao Tang
- Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, People's Republic of China
| | - Yongkang Pan
- Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, People's Republic of China
| | - Jie Wei
- Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, People's Republic of China
| | - Tingting Tang
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| |
Collapse
|
20
|
Dziadek M, Stodolak-Zych E, Cholewa-Kowalska K. Biodegradable ceramic-polymer composites for biomedical applications: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 71:1175-1191. [PMID: 27987674 DOI: 10.1016/j.msec.2016.10.014] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2016] [Revised: 09/18/2016] [Accepted: 10/13/2016] [Indexed: 01/11/2023]
Abstract
The present work focuses on the state-of-the-art of biodegradable ceramic-polymer composites with particular emphasis on influence of various types of ceramic fillers on properties of the composites. First, the general needs to create composite materials for medical applications are briefly introduced. Second, various types of polymeric materials used as matrices of ceramic-containing composites and their properties are reviewed. Third, silica nanocomposites and their material as well as biological characteristics are presented. Fourth, different types of glass fillers including silicate, borate and phosphate glasses and their effect on a number of properties of the composites are described. Fifth, wollastonite as a composite modifier and its effect on composite characteristics are discussed. Sixth, composites containing calcium phosphate ceramics, namely hydroxyapatite, tricalcium phosphate and biphasic calcium phosphate are presented. Finally, general possibilities for control of properties of composite materials are highlighted.
Collapse
Affiliation(s)
- Michal Dziadek
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Department of Glass Technology and Amorphous Coatings, 30 Mickiewicza Ave., 30-059 Krakow, Poland.
| | - Ewa Stodolak-Zych
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Department of Biomaterials, 30 Mickiewicza Ave., 30-059 Krakow, Poland.
| | - Katarzyna Cholewa-Kowalska
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Department of Glass Technology and Amorphous Coatings, 30 Mickiewicza Ave., 30-059 Krakow, Poland.
| |
Collapse
|
21
|
Panayotov IV, Orti V, Cuisinier F, Yachouh J. Polyetheretherketone (PEEK) for medical applications. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2016; 27:118. [PMID: 27259708 DOI: 10.1007/s10856-016-5731-4] [Citation(s) in RCA: 238] [Impact Index Per Article: 29.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Accepted: 05/24/2016] [Indexed: 05/22/2023]
Abstract
Polyetheretherketone (PEEK) is a polyaromatic semi-crystalline thermoplastic polymer with mechanical properties favorable for bio-medical applications. Polyetheretherketone forms: PEEK-LT1, PEEK-LT2, and PEEK-LT3 have already been applied in different surgical fields: spine surgery, orthopedic surgery, maxillo-facial surgery etc. Synthesis of PEEK composites broadens the physicochemical and mechanical properties of PEEK materials. To improve their osteoinductive and antimicrobial capabilities, different types of functionalization of PEEK surfaces and changes in PEEK structure were proposed. PEEK based materials are becoming an important group of biomaterials used for bone and cartilage replacement as well as in a large number of diverse medical fields. The current paper describes the structural changes and the surface functionalization of PEEK materials and their most common biomedical applications. The possibility to use these materials in 3D printing process could increase the scientific interest and their future development as well.
Collapse
Affiliation(s)
- Ivan Vladislavov Panayotov
- Laboratoire de Bioingénierie et Nanosciences EA 4203, UFR Odontologie, Université de Montpellier, 545 Avenue du Professeur Jean-Louis Viala, 34193, Montpellier Cedex 5, France.
| | - Valérie Orti
- Laboratoire de Bioingénierie et Nanosciences EA 4203, UFR Odontologie, Université de Montpellier, 545 Avenue du Professeur Jean-Louis Viala, 34193, Montpellier Cedex 5, France
| | - Frédéric Cuisinier
- Laboratoire de Bioingénierie et Nanosciences EA 4203, UFR Odontologie, Université de Montpellier, 545 Avenue du Professeur Jean-Louis Viala, 34193, Montpellier Cedex 5, France
| | - Jacques Yachouh
- Laboratoire de Bioingénierie et Nanosciences EA 4203, UFR Odontologie, Université de Montpellier, 545 Avenue du Professeur Jean-Louis Viala, 34193, Montpellier Cedex 5, France
| |
Collapse
|
22
|
Vaezi M, Black C, Gibbs DMR, Oreffo ROC, Brady M, Moshrefi-Torbati M, Yang S. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming. Molecules 2016; 21:molecules21060687. [PMID: 27240326 PMCID: PMC6273399 DOI: 10.3390/molecules21060687] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Revised: 05/20/2016] [Accepted: 05/20/2016] [Indexed: 11/21/2022] Open
Abstract
Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK) has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA) composite with a unique configuration in which the bioactive phase (i.e., HA) distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.
Collapse
Affiliation(s)
- Mohammad Vaezi
- Engineering Materials Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, UK.
| | - Cameron Black
- Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK.
| | - David M R Gibbs
- Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK.
| | - Richard O C Oreffo
- Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK.
| | - Mark Brady
- Invibio Ltd., Thornton-Cleveleys, Lancashire FY5 4QD, UK.
| | - Mohamed Moshrefi-Torbati
- Engineering Materials Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, UK.
| | - Shoufeng Yang
- Engineering Materials Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, UK.
| |
Collapse
|
23
|
Preparation Methods for Improving PEEK's Bioactivity for Orthopedic and Dental Application: A Review. Int J Biomater 2016; 2016:8202653. [PMID: 27127513 PMCID: PMC4834406 DOI: 10.1155/2016/8202653] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 02/25/2016] [Accepted: 03/07/2016] [Indexed: 11/30/2022] Open
Abstract
There is an increased interest in the use of polyether ether ketone (PEEK) for orthopedic and dental implant applications due to its elastic modulus close to that of bone, biocompatibility, and its radiolucent properties. However, PEEK is still categorized as bioinert due to its low integration with surrounding tissues. Many studies have reported on methods to increase the bioactivity of PEEK, but there is still one-preparation method for preparing bioactive PEEK implant where the produced implant with desirable mechanical and bioactivity properties is required. The aim of this review is to present the progress of the preparation methods for improvement of the bioactivity of PEEK and to discuss the strengths and weaknesses of the existing methods.
Collapse
|
24
|
Rao PJ, Pelletier MH, Walsh WR, Mobbs RJ. Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration. Orthop Surg 2015; 6:81-9. [PMID: 24890288 DOI: 10.1111/os.12098] [Citation(s) in RCA: 152] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Accepted: 02/18/2014] [Indexed: 01/09/2023] Open
Abstract
The clinical outcome of lumbar spinal fusion is correlated with achievement of bony fusion. Improving interbody implant bone on-growth and in-growth may enhance fusion, limiting pseudoarthrosis, stress shielding, subsidence and implant failure. Polyetheretherketone (PEEK) and titanium (Ti) are commonly selected for interbody spacer construction. Although these materials have desirable biocompatibility and mechanical properties, they require further modification to support osseointegration. Reports of extensive research on this topic are available in biomaterial-centric published reports; however, there are few clinical studies concerning surface modification of interbody spinal implants. The current article focuses on surface modifications aimed at fostering osseointegration from a clinician's point of view. Surface modification of Ti by creating rougher surfaces, modifying its surface topography (macro and nano), physical and chemical treatment and creating a porous material with high interconnectivity can improve its osseointegrative potential and bioactivity. Coating the surface with osteoconductive materials like hydroxyapatite (HA) can improve osseointegration. Because PEEK spacers are relatively inert, creating a composite by adding Ti or osteoconductive materials like HA can improve osseointegration. In addition, PEEK may be coated with Ti, effectively bio-activating the coating.
Collapse
Affiliation(s)
- Prashanth J Rao
- Neurospine Clinic, Prince of Wales Hospital, Sydney, NSW, Australia; University of New South Wales, Sydney, NSW, Australia; Surgical and Orthopaedics Research Laboratory, Sydney, NSW, Australia
| | | | | | | |
Collapse
|
25
|
Kizuki T, Matsushita T, Kokubo T. Apatite-forming PEEK with TiO2 surface layer coating. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:5359. [PMID: 25589201 DOI: 10.1007/s10856-014-5359-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Accepted: 09/07/2014] [Indexed: 05/15/2023]
Abstract
Polyetheretherketone (PEEK) is widely used in orthopedic implants, such as spinal fusion devices, because of its moderate elastic modulus, as well as relatively high mechanical strength. However, it does not bond to living bone, and hence it needs autograft to be fixed to the bone. In this study, we attempted to add bone-bonding properties to PEEK by coating with TiO2 synthesized by the sol-gel process. When a TiO2 sol solution consisting of titanium isopropoxide, water, ethanol, and nitric acid was deposited on a PEEK substrate without any pretreatment, the formed TiO2 gel layer was easily peeled off after subsequent treatments. However, when the same solution was deposited on PEEK that was preliminarily subjected to UV or O2 plasma treatment, the deposited TiO2 gel layer strongly adhered to the substrate even after subsequent treatments. The strong adhesion was attributed to the interaction among the C-O, C=O, and O-C=O groups on the PEEK owing to the UV or O2 plasma treatment and the Ti-O bond of the TiO2 gel. Apatite did not form on the as-formed TiO2 gel layer in a simulated body fluid (SBF) even within 3 days; however, apatite formed after soaking in 0.1 M HCl solution at 80 °C for 24 h. This apatite formation was attributed to positive surface charge of the TiO2 gel layer induced by the acid treatment. The PEEK with the TiO2 gel layer coating formed by the proposed process is expected to bond to living bone, because a positively charged titanium oxide which facilitates the formation of apatite in SBF within a short period is known to bond to living bone.
Collapse
Affiliation(s)
- Takashi Kizuki
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, 1200 Matsumoto-cho, Kasugai, Aichi, 487-8501, Japan,
| | | | | |
Collapse
|
26
|
Current strategies to improve the bioactivity of PEEK. Int J Mol Sci 2014; 15:5426-45. [PMID: 24686515 PMCID: PMC4013573 DOI: 10.3390/ijms15045426] [Citation(s) in RCA: 234] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2014] [Revised: 03/14/2014] [Accepted: 03/24/2014] [Indexed: 11/18/2022] Open
Abstract
The synthetic thermoplastic polymer polyetheretherketone (PEEK) is becoming a popular component of clinical orthopedic and spinal applications, but its practical use suffers from several limitations. Although PEEK is biocompatible, chemically stable, radiolucent and has an elastic modulus similar to that of normal human bone, it is biologically inert, preventing good integration with adjacent bone tissues upon implantation. Recent efforts have focused on increasing the bioactivity of PEEK to improve the bone-implant interface. Two main strategies have been used to overcome the inert character of PEEK. One approach is surface modification to activate PEEK through surface treatment alone or in combination with a surface coating. Another strategy is to prepare bioactive PEEK composites by impregnating bioactive materials into PEEK substrate. Researchers believe that modified bioactive PEEK will have a wide range of orthopedic applications.
Collapse
|
27
|
Shirazi FS, Moghaddam E, Mehrali M, Oshkour AA, Metselaar HSC, Kadri NA, Zandi K, Abu NA. In vitro characterization and mechanical properties of β-calcium silicate/POC composite as a bone fixation device. J Biomed Mater Res A 2014; 102:3973-85. [PMID: 24376053 DOI: 10.1002/jbm.a.35074] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Revised: 11/26/2013] [Accepted: 12/19/2013] [Indexed: 11/06/2022]
Abstract
Calcium silicate (CS, CaSiO3 ) is a bioactive, degradable, and biocompatible ceramic and has been considered for its potential in the field of orthopedic surgery. The objective of this study is the fabrication and characterization of the β-CS/poly(1.8-octanediol citrate) (POC) biocomposite, with the goals of controlling its weight loss and improving its biological and mechanical properties. POC is one of the most biocompatible polymers, and it is widely used in biomedical engineering applications. The degradation and bioactivity of the composites were determined by soaking the composites in phosphate-buffered saline and simulated body fluid, respectively. Human osteoblast cells were cultured on the composites to determine their cell proliferation and adhesion. The results illustrated that the flexural and compressive strengths were significantly enhanced by a modification of 40% POC. It was also concluded that the degradation bioactivity and amelioration of cell proliferation increased significantly with an increasing β-CS content.
Collapse
Affiliation(s)
- F S Shirazi
- Department of Mechanical Engineering and Advanced Material Research Center, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Kim IY, Ohtsuki C, Coughlan A, Placek L, Wren AW, Towler MR. Characteristics of glass ionomer cements composed of glass powders in CaO-SrO-ZnO-SiO₂ system prepared by two different synthetic routes. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2013; 24:2677-2682. [PMID: 23918526 DOI: 10.1007/s10856-013-5017-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Accepted: 07/22/2013] [Indexed: 06/02/2023]
Abstract
Glass ionomer cements (GICs) are composed of an acid degradable glass, polyacrylic acid and water. Sol-gel processing to prepare the glass phase has certain advantages, such as the ability to employ lower synthesis temperatures than melt quenching and glasses that are reported to have higher purity. A previous study reported the effects of glass synthesis route on GIC fabrication. However, in that study, the sol-gel derived glass exhibited a reduced concentration of cations. This study investigates increasing the cation content of a sol-gel derived glass, 12CaO.4SrO.36ZnO.48SiO2 (molar ratio) by heating before aging to reduce dissolution of cations. This glass was prepared by both sol-gel and melt-quenched routes. GICs were subsequently prepared using both glasses. The resultant cement based on the sol-gel derived glass had a shorter working time than the cement based on the melt-quenched one. Contrary to this, setting time was considerably longer for the cement based on the sol-gel derived glass than for the cement based on the melt-quenched one. The cements based on the sol-gel derived glass were stronger in both compression and biaxial flexure than the cements prepared from the melt-quenched glass. The differences in setting and mechanical properties were associated with both cation content in the glass phase and the different surface area of the resultant cements.
Collapse
Affiliation(s)
- Ill Yong Kim
- Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan,
| | | | | | | | | | | |
Collapse
|
29
|
Abstract
PEEK based composites have been increasingly employed as biomaterials due to its excellent biological characteristics. In this paper, the biocompatibility, bioactivity, bio-tribology and biomechanics of PEEK composites were investigated. The results showed that PEEK possesses excellent cellular and blood compatibility. The bioactivity of PEEK could be improved by various techniques such as plasma treatment, surface grafting, surface deposition and addition of bioactive glass ceramic in the PEEK matrix. The results of bio-tribology showed that the biotribological properties of PEEK based composites could be comparable with that of traditional artificial joint materials such as UHMWPE. It is even superior to UHMWPE under certain conditions. The biomechanical properties of PEEK composites showed that they can improve the initial stability, reduce the stress shielding and improve bonding strength between bone and implant after replacement, while they are compared with traditional implants such as stainless steel, titanium alloy and Co-Cr-Mo alloy.
Collapse
|
30
|
Abstract
Osteoconductive bone-repairing materials with mechanical properties analogous to those of human bone can be prepared through the combination of an osteoconductive ceramic filler with an organic polymer. Osteoconduction is archived from apatite formation on substrates. Previously, we reported that novel osteoconductive spherical particles in a binary CaO-SiO2 system were produced through a sol-gel process as ceramic filler for the fabrication of composites. In this study, we fabricated the composites consisting of polyetheretherketone (PEEK) and 30CaO·70SiO2 (CS) spherical particles and evaluated the effects of heat treatment in the range of 320-360 °C on apatite formation of the composites in a simulated body fluid. The prepared composites of PEEK and CS particles form hydroxyapatite on their surfaces in the simulated body fluid. The induction periods of hydroxyapatite on the composites decreased with increasing the amount of CS particles and decreasing the temperature for heat treatment. The apatite formation was affected by exposure of ceramic filler on the polymer matrix.
Collapse
|
31
|
Musib M, Saha S. Nanostructured materials for bone tissue replacement. Nanomedicine (Lond) 2012. [DOI: 10.1533/9780857096449.4.599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
32
|
Characterization of PEEK biomaterials using the small punch test. J Mech Behav Biomed Mater 2011; 4:1275-82. [PMID: 21783136 DOI: 10.1016/j.jmbbm.2011.04.014] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2011] [Revised: 04/12/2011] [Accepted: 04/15/2011] [Indexed: 11/21/2022]
Abstract
The small punch test is widely used to characterize the ductility and fracture resistance in metals and ceramics, when only a small volume of material is available. This study was conducted to investigate the suitability of the small punch test for characterizing polyetheretherketone (PEEK) polymeric biomaterials for changes in material grade, crystallinity, and molding process. The small punch test reproducibly characterized the mechanical behavior of PEEK and was able to distinguish differences induced by molding process alterations and annealing. Peak load was most sensitive to changes in crystallinity, grade, molding process, and increased with increasing crystallinity, but decreased with the addition of image contrast materials. The ultimate displacement was negatively correlated with crystallinity. Molding process conditions had the greatest influence on metrics of the small punch test, when compared with the effects of annealing and the addition of a radiopacifier. The results of this study validate the small punch test as a repeatable method for measuring the mechanical behavior of PEEK biomaterials.
Collapse
|
33
|
Wagoner Johnson AJ, Herschler BA. A review of the mechanical behavior of CaP and CaP/polymer composites for applications in bone replacement and repair. Acta Biomater 2011; 7:16-30. [PMID: 20655397 DOI: 10.1016/j.actbio.2010.07.012] [Citation(s) in RCA: 339] [Impact Index Per Article: 26.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2010] [Revised: 07/09/2010] [Accepted: 07/12/2010] [Indexed: 12/22/2022]
Abstract
Repair of load-bearing defects resulting from disease or trauma remains a critical barrier for bone tissue engineering. Calcium phosphate (CaP) scaffolds are among the most extensively studied for this application. However, CaPs are reportedly too weak for use in such defects and, therefore, have been limited to non-load-bearing applications. This paper reviews the compression, flexural and tensile properties of CaPs and CaP/polymer composites for applications in bone replacement and repair. This review reveals interesting trends that have not, to our knowledge, previously been reported. Data are classified as bulk, scaffolds, and composites, then organized in order of decreasing strength. This allows for general comparisons of magnitudes of strength both within and across classifications. Bulk and scaffold strength and porosity overlap significantly and scaffold data are comparable to bone both in strength and porosity. Further, for compression, all composite data fall below those of the bulk and most of the scaffold. Another interesting trend revealed is that strength decreases with increasing β-tricalcium phosphate (β-TCP) content for CaP scaffolds and with increasing CaP content for CaP/polymer composites. The real limitation for CaPs appears not to be strength necessarily, but toughness and reliability, which are rarely characterized. We propose that research should focus on novel ways of toughening CaPs and discuss several potential strategies.
Collapse
|
34
|
Brochu ABW, Craig SL, Reichert WM. Self-healing biomaterials. J Biomed Mater Res A 2010; 96:492-506. [PMID: 21171168 DOI: 10.1002/jbm.a.32987] [Citation(s) in RCA: 99] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Revised: 07/16/2010] [Accepted: 09/21/2010] [Indexed: 11/11/2022]
Abstract
The goal of this review is to introduce the biomaterials community to the emerging field of self-healing materials, and also to suggest how one could utilize and modify self-healing approaches to develop new classes of biomaterials. A brief discussion of the in vivo mechanical loading and resultant failures experienced by biomedical implants is followed by presentation of the self-healing methods for combating mechanical failure. If conventional composite materials that retard failure may be considered zeroth generation self-healing materials, then taxonomically speaking, first generation self-healing materials describe approaches that "halt" and "fill" damage, whereas second generation self-healing materials strive to "fully restore" the prefailed material structure. In spite of limited commercial use to date, primarily because the technical details have not been suitably optimized, it is likely from a practical standpoint that first generation approaches will be the first to be employed commercially, whereas second generation approaches may take longer to implement. For self-healing biomaterials the optimization of technical considerations is further compounded by the additional constraints of toxicity and biocompatibility, necessitating inclusion of separate discussions of design criteria for self-healing biomaterials.
Collapse
Affiliation(s)
- Alice B W Brochu
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708-0281, USA
| | | | | |
Collapse
|