1
|
Htay H, Johnson DW, Wiggins KJ, Badve SV, Craig JC, Strippoli GFM, Cho Y. Biocompatible dialysis fluids for peritoneal dialysis. Cochrane Database Syst Rev 2018; 10:CD007554. [PMID: 30362116 PMCID: PMC6517187 DOI: 10.1002/14651858.cd007554.pub3] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND Biocompatible peritoneal dialysis (PD) solutions, including neutral pH, low glucose degradation product (GDP) solutions and icodextrin, have previously been shown to favourably influence some patient-level outcomes, albeit based on generally sub-optimal quality studies. Several additional randomised controlled trials (RCT) evaluating biocompatible solutions in PD patients have been published recently. This is an update of a review first published in 2014. OBJECTIVES This review aimed to look at the benefits and harms of biocompatible PD solutions in comparison to standard PD solutions in patients receiving PD. SEARCH METHODS The Cochrane Kidney and Transplant Specialised Register was searched up to 12 February 2018 through contact with the Information Specialist using search terms relevant to this review. Studies in the Specialised Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Register Search Portal and ClinicalTrials.gov. SELECTION CRITERIA All RCTs and quasi-RCTs in adults and children comparing the effects of biocompatible PD solutions (neutral pH, lactate-buffered, low GDP; neutral pH, bicarbonate(± lactate)-buffered, low GDP; glucose polymer (icodextrin)) in PD were included. Studies of amino acid-based solutions were excluded. DATA COLLECTION AND ANALYSIS Two authors extracted data on study quality and outcomes. Summary effect estimates were obtained using a random-effects model, and results were expressed as risk ratios and 95% confidence intervals (CI) for categorical variables, and mean differences (MD) or standardised mean differences (SMD) and 95% CI for continuous variables. MAIN RESULTS This review update included 42 eligible studies (3262 participants), including six new studies (543 participants). Overall, 29 studies (1971 participants) compared neutral pH, low GDP PD solution with conventional PD solution, and 13 studies (1291 participants) compared icodextrin with conventional PD solution. Risk of bias was assessed as high for sequence generation in three studies, allocation concealment in three studies, attrition bias in 21 studies, and selective outcome reporting bias in 16 studies.Neutral pH, low GDP versus conventional glucose PD solutionUse of neutral pH, low GDP PD solutions improved residual renal function (RRF) preservation (15 studies, 835 participants: SMD 0.19, 95% CI 0.05 to 0.33; high certainty evidence). This approximated to a mean difference in glomerular filtration rate of 0.54 mL/min/1.73 m2 (95% CI 0.14 to 0.93). Better preservation of RRF was evident at all follow-up durations with progressively greater preservation observed with increasing follow up duration. Neutral pH, low GDP PD solution use also improved residual urine volume preservation (11 studies, 791 participants: MD 114.37 mL/day, 95% CI 47.09 to 181.65; high certainty evidence). In low certainty evidence, neutral pH, low GDP solutions may make little or no difference to 4-hour peritoneal ultrafiltration (9 studies, 414 participants: SMD -0.42, 95% CI -0.74 to -0.10) which approximated to a mean difference in peritoneal ultrafiltration of 69.72 mL (16.60 to 122.00 mL) lower, and may increase dialysate:plasma creatinine ratio (10 studies, 746 participants: MD 0.01, 95% CI 0.00 to 0.03), technique failure or death compared with conventional PD solutions. It is uncertain whether neutral pH, low GDP PD solution use led to any differences in peritonitis occurrence, hospitalisation, adverse events (6 studies, 519 participants) or inflow pain (1 study, 58 participants: RR 0.51, 95% CI 0.24 to 1.08).Glucose polymer (icodextrin) versus conventional glucose PD solutionIn moderate certainty evidence, icodextrin probably reduced episodes of uncontrolled fluid overload (2 studies, 100 participants: RR 0.30, 95% CI 0.15 to 0.59) and augmented peritoneal ultrafiltration (4 studies, 102 participants: MD 448.54 mL/d, 95% CI 289.28 to 607.80) without compromising RRF (4 studies, 114 participants: SMD 0.12, 95% CI -0.26 to 0.49; low certainty evidence) which approximated to a mean creatinine clearance of 0.30 mL/min/1.73m2 higher (0.65 lower to 1.23 higher) or urine output (3 studies, 69 participants: MD -88.88 mL/d, 95% CI -356.88 to 179.12; low certainty evidence). It is uncertain whether icodextrin use led to any differences in adverse events (5 studies, 816 participants) technique failure or death. AUTHORS' CONCLUSIONS This updated review strengthens evidence that neutral pH, low GDP PD solution improves RRF and urine volume preservation with high certainty. These effects may be related to increased peritoneal solute transport and reduced peritoneal ultrafiltration, although the evidence for these outcomes is of low certainty due to significant heterogeneity and suboptimal methodological quality. Icodextrin prescription increased peritoneal ultrafiltration and mitigated uncontrolled fluid overload with moderate certainty. The effects of either neutral pH, low GDP solution or icodextrin on peritonitis, technique survival and patient survival remain uncertain and require further high quality, adequately powered RCTs.
Collapse
Affiliation(s)
- Htay Htay
- Singapore General HospitalDepartment of Renal Medicine20 College StreetSingaporeSingapore169856
| | - David W Johnson
- Princess Alexandra HospitalDepartment of NephrologyIpswich RoadWoolloongabbaQueenslandAustralia4102
- University of QueenslandBrisbaneAustralia
| | | | - Sunil V Badve
- St George HospitalDepartment of NephrologyKogarahNSWAustralia
| | - Jonathan C Craig
- The Children's Hospital at WestmeadCochrane Kidney and Transplant, Centre for Kidney ResearchWestmeadNSWAustralia2145
- Flinders UniversityCollege of Medicine and Public HealthAdelaideSAAustralia5001
| | - Giovanni FM Strippoli
- The Children's Hospital at WestmeadCochrane Kidney and Transplant, Centre for Kidney ResearchWestmeadNSWAustralia2145
- University of BariDepartment of Emergency and Organ TransplantationBariItaly
- DiaverumMedical Scientific OfficeLundSweden
- Diaverum AcademyBariItaly
| | - Yeoungjee Cho
- Princess Alexandra HospitalDepartment of NephrologyIpswich RoadWoolloongabbaQueenslandAustralia4102
- University of QueenslandBrisbaneAustralia
| | | |
Collapse
|
2
|
Seo EY, An SH, Cho JH, Suh HS, Park SH, Gwak H, Kim YL, Ha H. Effect of biocompatible peritoneal dialysis solution on residual renal function: a systematic review of randomized controlled trials. Perit Dial Int 2014; 34:724-31. [PMID: 25185015 DOI: 10.3747/pdi.2012.00331] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
INTRODUCTION Residual renal function (RRF) plays an important role in outcome of peritoneal dialysis (PD) including mortality. It is, therefore, important to provide a strategy for the preservation of RRF. The objective of this study was to evaluate relative protective effects of new glucose-based multicompartmental PD solution (PDS), which is well known to be more biocompatible than glucose-based conventional PDS, on RRF compared to conventional PDS by performing a systematic review (SR) of randomized controlled trials. METHODS We searched studies presented up to January 2014 in MEDLINE, EMBASE, the COCHRANE library, and local databases. Three independent reviewers reviewed and extracted prespecified data from each study. The random effects model, a more conservative analysis model, was used to combine trials and to perform stratified analyses based on the duration of follow-up. Study quality was assessed using the Cochrane Handbook for risk of bias. Eleven articles with 1,034 patients were identified for the SR. RESULTS The heterogeneity of the studies under 12 months was very high, and the heterogeneity decreased substantially when we stratified studies by the duration of follow-up. The mean difference of the studies after 12 months was 0.46 mL/min/1.73 m(2) (95% confidence interval = 0.25 to + 0.67). CONCLUSION New PDS showed the effect to preserve and improve RRF for long-term use compared to conventional PDS, even though it did not show a significant difference to preserve RRF for short-term use.
Collapse
Affiliation(s)
- Eun-Young Seo
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Sook Hee An
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Jang-Hee Cho
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Hae Sun Suh
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Sun-Hee Park
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Hyesun Gwak
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Yong-Lim Kim
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| | - Hunjoo Ha
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Global Top5 Program, Ewha Womans University, Seoul, Korea; Department of Pharmacy, Wonkwang University, Iksan City, Jeonbuk, Korea; Division of Nephrology and Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea; and College of Pharmacy, Pusan National University, Korea
| |
Collapse
|
3
|
Cho Y, Johnson DW, Craig JC, Strippoli GFM, Badve SV, Wiggins KJ. Biocompatible dialysis fluids for peritoneal dialysis. Cochrane Database Syst Rev 2014:CD007554. [PMID: 24671928 DOI: 10.1002/14651858.cd007554.pub2] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND The longevity of peritoneal dialysis (PD) is limited by high rates of technique failure, some of which stem from peritoneal membrane injury. 'Biocompatible' PD solutions have been developed to reduce damage to the peritoneal membrane. OBJECTIVES This review aimed to look at the benefits and harms of biocompatible PD solutions in comparison to standard PD solutions in patients receiving PD. SEARCH METHODS We searched the Cochrane Renal Group's Specialised Register (28 February 2013), through contact with the Trials Search Co-ordinator using search terms relevant to this review. Studies contained in the Specialised Register are identified through search strategies specifically designed for CENTRAL, MEDLINE and EMBASE, and handsearching conference proceedings. SELECTION CRITERIA All randomised controlled trials (RCTs) and quasi-RCTs in adults and children comparing the effects of biocompatible PD solutions (neutral pH, lactate-buffered, low glucose degradation product (GDP); neutral pH, bicarbonate (± lactate)-buffered, low GDP; glucose polymer (icodextrin)) in PD were included. Studies of amino acid-based PD solutions were excluded. DATA COLLECTION AND ANALYSIS Two authors extracted data on study quality and outcomes (including adverse effects). The authors contacted investigators to obtain missing information. Summary estimates of effect were obtained using a random-effects model, and results were expressed as risk ratios (RR) and their 95% confidence intervals (CI) for categorical variables, and mean difference (MD) or standardised mean difference (SMD) and 95% CI for continuous variables. MAIN RESULTS Thirty-six eligible studies (2719 patients) were identified: Neutral pH, lactate-buffered/bicarbonate (± lactate)-buffered, low GDP PD solution (24); icodextrin (12). Allocation methods and concealment were generally incompletely reported, and adequate in only ten studies (27.8%). Patients lost to follow-up ranged from 0% to 83.4%. Neutral pH, low GDP versus conventional glucose PD solutionBased on generally sub-optimal quality evidence, the use of neutral pH, low GDP PD solutions was associated with larger urine volumes at the end of the studies, up to three years of therapy duration (7 studies, 520 patients: MD 126.39 mL/d, 95% CI 26.73 to 226.05). Improved preservation of residual renal function was evident in studies with greater than 12 month follow-up (6 studies, 360 patients: SMD 0.31, 95% CI 0.10 to 0.52). There was no significant effect on peritonitis, technique failure or adverse events with the use of neutral pH, low GDP PD solutions. Glucose polymer (icodextrin) versus conventional glucose PD solutionThere was a significant reduction in episodes of uncontrolled fluid overload (2 studies, 100 patients: RR 0.30, 95% CI 0.15 to 0.59) and improvement in peritoneal ultrafiltration (4 studies, 102 patients, MD 448.54 mL/d, 95% CI 289.28 to 607.80) without compromising residual renal function (4 studies, 114 patients: SMD 0.12, 95% CI -0.26 to 0.49) or urine output (3 studies, 69 patients: MD -88.88 mL/d, 95% CI -356.88 to 179.12) with icodextrin use. A comparable incidence of adverse events with the icodextrin (four studies) was reported. AUTHORS' CONCLUSIONS Based on generally sub-optimal quality studies, use of neutral pH, low GDP PD solution led to greater urine output and higher residual renal function after use exceeded 12 months. Icodextrin prescription improved peritoneal ultrafiltration and mitigated uncontrolled fluid overload. There were no significant effects on peritonitis, technique survival, patient survival or harms identified with their use. Based on the best available evidence, the use of these 'biocompatible' PD solutions resulted in clinically relevant benefits without added risks of harm.
Collapse
Affiliation(s)
- Yeoungjee Cho
- Department of Nephrology, Princess Alexandra Hospital, ARTS Building, Ipswich Rd, Woolloongabba, Queensland, Australia, 4012
| | | | | | | | | | | |
Collapse
|
5
|
Lee HY, Choi HY, Park HC, Seo BJ, Do JY, Yun SR, Song HY, Kim YH, Kim YL, Kim DJ, Kim YS, Kim MJ, Shin SK. Changing prescribing practice in CAPD patients in Korea: increased utilization of low GDP solutions improves patient outcome. Nephrol Dial Transplant 2006; 21:2893-9. [PMID: 16957012 DOI: 10.1093/ndt/gfl393] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Novel, biocompatible peritoneal dialysis (PD) solutions have become available in recent years. In 2001, low glucose degradation products (GDP), neutral pH solutions became commercially available in Korea. To date, there are no reports regarding the large scale adoption of these solutions in clinical practice and regarding what, if any, impact these solutions have on patient outcomes. METHODS Using a database of almost 4000 patients treated by PD in Korea, we conducted a prospective, longitudinal observational study documenting the patterns of use of one novel low GDP solution (balance, Fresenius Medical Care, St Wendel, Germany) in 1909 PD incident patients between 1 January 2002 and midyear 2005. Outcomes including patient and technique survival and peritonitis rates were analysed using univariate and multivariate analysis. RESULTS Prescription of low GDP solutions reached between 70 and 80% by the year 2003 and persisted at this level. Patients prescribed low GDP PD solution tended to be younger and were more likely to be treated in centres with larger enrollment in the database. Survival of diabetic patients treated with the new PD solution was identical to that of the non-diabetic patients treated with standard PD fluids (PDF) and treatment with low GDP PDF independently reduced the relative risk (RR) of death (RR = 0.613; CI 0.50-0.74; P < 0.00001) in a proportional hazards model which included age, diabetes and centre experience. In a univariate analysis, low GDP PD solution was associated with a longer technique survival (P = 0.049) but this effect was not significant in multivariate analysis. No significant differences in peritonitis-free interval or peritonitis rate could be attributed to the prescribed PDF. CONCLUSION Prescription of low GDP, pH-neutral PD solutions has rapidly increased in Korea. This change has resulted in a significant improvement in patient and technique survival without any measurable change in peritonitis incidence or rate. Reasons for the improved patient survival cannot be determined from this analysis and require further study.
Collapse
Affiliation(s)
- Ho Yung Lee
- Department of Internal Medicine, Yonsei University College of Medicine, CPO Box 8044, Seoul, Korea.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|