Chung Y, Joh JH, Park HC. Measuring of Abdominal Aortic Aneurysm with Three-Dimensional Computed Tomography Reconstruction before Endovascular Aortic Aneurysm Repair.
Vasc Specialist Int 2017;
33:27-32. [PMID:
28377909 PMCID:
PMC5374957 DOI:
10.5758/vsi.2017.33.1.27]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 01/21/2017] [Accepted: 01/24/2017] [Indexed: 11/20/2022] Open
Abstract
PURPOSE
Conventional computed tomography (CT) is the gold standard method for case planning for endovascular aortic aneurysm repair (EVAR). However, aortography with a marking catheter is needed for measuring the actual length of an aneurysm. With advances in imaging technology, a 3-dimensional (3D) workstation can obviate the need for the aortography. The objective of this study was to determine whether a 3D workstation could obviate the need for aortography for EVAR.
MATERIALS AND METHODS
One vascular surgeon and 1 interventional radiologist retrospectively assessed axial CT scans and reformatted the 3D CT scans by using the iNtuition workstation (TeraRecon Inc., San Mateo, CA, USA) for 25 patients who underwent EVAR. Four measurements of diameter and length were obtained from each modality. The actual length of an aneurysm for the proper graft was decided by 2 observers by reviewing the aortography with a marking catheter.
RESULTS
The measurements from the 2 modalities were reproducible with intraobserver correlation coefficients of 0.89 to 1.0 for conventional CT and 0.98 to 1.0 for 3D workstation. Interobserver correlation coefficients were 0.29 to 0.95 for conventional CT and 0.85 to 0.99 for the 3D workstation. The length of the aneurysm for proper main graft coincided in 18 and 14 patients according to the conventional CT scan and in 21 and 18 patients according to the 3D workstation, respectively.
CONCLUSION
The interobserver agreement in planning EVAR was significantly better with the iNtuition 3D workstation. But aortography with a marking catheter may still be needed for selecting the proper graft.
Collapse