1
|
Malatos S, Fazzini L, Raptis A, Nana P, Kouvelos G, Tasso P, Gallo D, Morbiducci U, Xenos MA, Giannoukas A, Matsagkas M. Evaluation of Hemodynamic Properties After Chimney and Fenestrated Endovascular Aneurysm Repair. Ann Vasc Surg 2024; 104:237-247. [PMID: 38492732 DOI: 10.1016/j.avsg.2023.12.084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 12/14/2023] [Accepted: 12/16/2023] [Indexed: 03/18/2024]
Abstract
BACKGROUND Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.
Collapse
Affiliation(s)
- Stavros Malatos
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece
| | - Laura Fazzini
- Department of Mechanical and Aerospace Engineering, Biomedical Engineering, Politecnico di Torino, Torino, Italy
| | - Anastasios Raptis
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece
| | - Petroula Nana
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece.
| | - George Kouvelos
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Paola Tasso
- Department of Mechanical and Aerospace Engineering, Biomedical Engineering, Politecnico di Torino, Torino, Italy
| | - Diego Gallo
- Department of Mechanical and Aerospace Engineering, Biomedical Engineering, Politecnico di Torino, Torino, Italy
| | - Umberto Morbiducci
- Department of Mechanical and Aerospace Engineering, Biomedical Engineering, Politecnico di Torino, Torino, Italy
| | - Michail A Xenos
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece; Department of Mathematics, Section of Applied and Computational Mathematics, University of Ioannina, Ioannina, Greece
| | - Athanasios Giannoukas
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Miltiadis Matsagkas
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| |
Collapse
|
2
|
Tran K, Deslarzes-Dubuis C, DeGlise S, Kaladji A, Yang W, Marsden AL, Lee JT. Patient-specific computational flow simulation reveals significant differences in paravisceral aortic hemodynamics between fenestrated and branched endovascular aneurysm repair. JVS Vasc Sci 2023; 5:100183. [PMID: 38314201 PMCID: PMC10832507 DOI: 10.1016/j.jvssci.2023.100183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 11/10/2023] [Indexed: 02/06/2024] Open
Abstract
Background Endovascular aneurysm repair with four-vessel fenestrated endovascular aneurysm repair (fEVAR) or branched endovascular aneurysm repair (bEVAR) currently represent the forefront of minimally invasive complex aortic aneurysm repair. This study sought to use patient-specific computational flow simulation (CFS) to assess differences in postoperative hemodynamic effects associated with fEVAR vs bEVAR. Methods Patients from two institutions who underwent four-vessel fEVAR with the Cook Zenith Fenestrated platform and bEVAR with the Jotec E-xtra Design platform were retrospectively selected. Patients in both cohorts were treated for paravisceral and extent II, II, and V thoracoabdominal aortic aneurysms. Three-dimensional finite element volume meshes were created from preoperative and postoperative computed tomography scans. Boundary conditions were adjusted for body surface area, heart rate, and blood pressure. Pulsatile flow simulations were performed with equivalent boundary conditions between preoperative and postoperative states. Postoperative changes in hemodynamic parameters were compared between the fEVAR and bEVAR groups. Results Patient-specific CFS was performed on 20 patients (10 bEVAR, 10 fEVAR) with a total of 80 target vessels (40 renal, 20 celiac, 20 superior mesenteric artery stents). bEVAR was associated with a decrease in renal artery peak flow rate (-5.2% vs +2.0%; P < .0001) and peak pressure (-3.4 vs +0.1%; P < .0001) compared with fEVAR. Almost all renal arteries treated with bEVAR had a reduction in renal artery perfusion (n = 19 [95%]), compared with 35% (n = 7) treated with fEVAR. There were no significant differences in celiac or superior mesenteric artery perfusion metrics (P = .10-.27) between groups. Time-averaged wall shear stress in the paravisceral aorta and branches also varied significantly depending on endograft configuration, with bEVAR associated with large postoperative increases in renal artery (+47.5 vs +13.5%; P = .002) and aortic time-averaged wall shear stress (+200.1% vs -31.3%; P = .001) compared with fEVAR. Streamline analysis revealed areas of hemodynamic abnormalities associated with branched renal grafts which adopt a U-shaped geometry, which may explain the observed differences in postoperative changes in renal perfusion between bEVAR and fEVAR. Conclusions bEVAR may be associated with subtle decreases in renal perfusion and a large increase in aortic wall shear stress compared with fEVAR. CFS is a novel tool for quantifying and visualizing the unique patient-specific hemodynamic effect of different complex EVAR strategies. Clinical Relevance This study used patient-specific CFS to compare postoperative hemodynamic effects of four-vessel fenestrated endovascular aneurysm repair (fEVAR) and branched endovascular aneurysm repair (bEVAR) in patients with complex aortic aneurysms. The findings indicate that bEVAR may result in subtle reductions in renal artery perfusion and a significant increase in aortic wall shear stress compared with fEVAR. These differences are clinically relevant, providing insights for clinicians choosing between these approaches. Understanding the patient-specific hemodynamic effects of complex EVAR strategies, as revealed by CFS, can aid in future personalized treatment decisions, and potentially reduce postoperative complications in aortic aneurysm repair.
Collapse
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford Healthcare, Stanford, CA
| | | | - Sebastien DeGlise
- Division of Vascular Surgery, Lausanne University Hospital, Lausanne, Switzerland
| | - Adrien Kaladji
- Department of Vascular Surgery, University of Rennes, Paris, France
| | - Weiguang Yang
- Department of Mechanical Engineering, Stanford University, Stanford, CA
| | - Alison L Marsden
- Department of Mechanical Engineering, Stanford University, Stanford, CA
| | - Jason T Lee
- Division of Vascular Surgery, Stanford Healthcare, Stanford, CA
| |
Collapse
|
3
|
Tran K, Kaladji A, Yang W, Marsden AL, Lee JT. Assessing Differences in Aortic Haemodynamics Between Two vs. Four Vessel Fenestrated Endovascular Aortic Repair using Patient Specific Computational Flow Simulation. Eur J Vasc Endovasc Surg 2023; 66:739-740. [PMID: 37536515 DOI: 10.1016/j.ejvs.2023.07.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 06/26/2023] [Accepted: 07/28/2023] [Indexed: 08/05/2023]
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford Health Care, Stanford, CA, USA.
| | - Adrien Kaladji
- Department of Vascular Surgery, University of Rennes, Paris, France
| | - Weiguang Yang
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Alison L Marsden
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Jason T Lee
- Division of Vascular Surgery, Stanford Health Care, Stanford, CA, USA
| |
Collapse
|
4
|
Cha MJ, An DG, Kang M, Kim HM, Kim SW, Cho I, Hong J, Choi H, Cho JH, Shin SY, Song S. Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging. Korean J Radiol 2023; 24:647-659. [PMID: 37404107 DOI: 10.3348/kjr.2023.0173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 04/06/2023] [Accepted: 04/17/2023] [Indexed: 07/06/2023] Open
Abstract
OBJECTIVE The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. MATERIALS AND METHODS Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold (|V̅| < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. RESULTS Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surface-and-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa-1 , respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa-1 , respectively) and pre-occlusion (0.072 Pa and 5.861 Pa-1 , respectively) models. CONCLUSION These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF.
Collapse
Affiliation(s)
- Min Jae Cha
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Don-Gwan An
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul, Korea
- Center for Precision Medicine Platform Based-on Smart Hemo-Dynamic Index, Seoul, Korea
| | - Minsoo Kang
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul, Korea
- Center for Precision Medicine Platform Based-on Smart Hemo-Dynamic Index, Seoul, Korea
| | - Hyue Mee Kim
- Division of Cardiology, Department of Internal Medicine, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Sang-Wook Kim
- Division of Cardiology, Department of Internal Medicine, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Iksung Cho
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Yonsei University Health System, Seoul, Korea
| | - Joonhwa Hong
- Department of Thoracic and Cardiovascular Surgery, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Hyewon Choi
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Jee-Hyun Cho
- Bio-Chemical Analysis Team, Korea Basic Science Institute, Cheongju, Korea
| | - Seung Yong Shin
- Center for Precision Medicine Platform Based-on Smart Hemo-Dynamic Index, Seoul, Korea
- Division of Cardiology, Department of Internal Medicine, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.
| | - Simon Song
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul, Korea
- Center for Precision Medicine Platform Based-on Smart Hemo-Dynamic Index, Seoul, Korea
- Institute of Nano Science and Technology, Hanyang University, Seoul, Korea.
| |
Collapse
|
5
|
Tran K, Feliciano KB, Yang W, Schwarz EL, Marsden AL, Dalman RL, Lee JT. Patient-specific changes in aortic hemodynamics is associated with thrombotic risk after fenestrated endovascular aneurysm repair with large diameter endografts. JVS Vasc Sci 2022; 3:219-231. [PMID: 35647564 PMCID: PMC9133635 DOI: 10.1016/j.jvssci.2022.04.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 04/06/2022] [Indexed: 12/24/2022] Open
Abstract
Background The durability of fenestrated endovascular aneurysm repair (fEVAR) has been threatened by thrombotic complications. In the present study, we used patient-specific computational fluid dynamic (CFD) simulation to investigate the effect of the endograft diameter on hemodynamics after fEVAR and explore the hypothesis that diameter-dependent alterations in aortic hemodynamics can predict for thrombotic events. Methods A single-institutional retrospective study was performed of patients who had undergone fEVAR for juxtarenal aortic aneurysms. The patients were stratified into large diameter (34-36 mm) and small diameter (24-26 mm) endograft groups. Patient-specific CFD simulations were performed using three-dimensional paravisceral aortic models created from computed tomographic images with allometrically scaled boundary conditions. Aortic time-averaged wall shear stress (TAWSS) and residence time (RT) were computed and correlated with future thrombotic complications (eg, renal stent occlusion, development of significant intraluminal graft thrombus). Results A total of 36 patients (14 with a small endograft and 22 with a large endograft) were included in the present study. The patients treated with large endografts had experienced a higher incidence of thrombotic complications compared with small endografts (45.5% vs 7.1%; P = .016). Large endografts were associated with a lower postoperative aortic TAWSS (1.45 ± 0.76 dynes/cm2 vs 3.16 ± 1.24 dynes/cm2; P < .001) and longer aortic RT (0.78 ± 0.30 second vs 0.34 ± 0.08 second; P < .001). In the large endograft group, a reduction >0.39 dynes/cm2 in aortic TAWSS demonstrated discriminatory power for thrombotic complications (area under the receiver operating characteristic curve, 0.77). An increased aortic RT of ≥0.05 second had similar accuracy for predicting thrombotic complications (area under the receiver operating characteristic curve, 0.78). The odds of thrombotic complications were significantly higher if patients had met the hemodynamic threshold changes in aortic TAWSS (odds ratio, 7.0; 95% confidence interval, 1.1-45.9) and RT (odds ratio, 8.0; 95% confidence interval, 1.13-56.8). Conclusions Patient-specific CFD simulation of fEVAR in juxtarenal aortic aneurysms demonstrated significant endograft diameter-dependent differences in aortic hemodynamics. A postoperative reduction in TAWSS and an increased RT correlated with future thrombotic events after large-diameter endograft implantation. Patient-specific simulation of hemodynamics provides a novel method for thrombotic risk stratification after fEVAR. The durability of fenestrated endovascular aneurysm repair (fEVAR) has been threatened by thrombotic complications. Using patient-specific computational flow simulation, the present retrospective study of 36 patients with juxtarenal aortic aneurysms treated with fEVAR identified several endograft diameter-dependent changes in aortic hemodynamics associated with thrombotic complications. A postoperative reduction in aortic wall shear stress and increased particle residence time correlated with the development of intraluminal graft thrombus and renal stent occlusion in patients treated with large diameter (>34 mm) endografts. These computationally estimated hemodynamic parameters could provide a novel method for patient-specific risk stratification for adverse events after fEVAR.
Collapse
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
- Correspondence: Kenneth Tran, MD, Department of Vascular Surgery, Stanford University School of Medicine, 300 Pasteur Dr, Ste H3600, Stanford, CA 94305-5851
| | - K. Brennan Feliciano
- Department of Bioengineering, Stanford University School of Medicine, Stanford, CA
| | - Weiguang Yang
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, CA
| | - Erica L. Schwarz
- Department of Bioengineering, Stanford University School of Medicine, Stanford, CA
| | - Alison L. Marsden
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
- Department of Bioengineering, Stanford University School of Medicine, Stanford, CA
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, CA
| | - Ronald L. Dalman
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
| | - Jason T. Lee
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
| |
Collapse
|
6
|
van der Riet C, Schuurmann RCL, Bokkers RPH, van der Zijden FA, Tielliu IFJ, Slump CH, de Vries JPPM. In Vitro Geometry Analysis of Fenestrations in Endovascular Aneurysm Repair. J Endovasc Ther 2022; 30:204-213. [PMID: 35227104 PMCID: PMC10052373 DOI: 10.1177/15266028221079755] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE Changes in the flared end of balloon-expandable covered stent (BECS) may precede BECS-associated complications but are not regularly assessed with computed tomographic angiography (CTA) after fenestrated endovascular aneurysm repair (FEVAR). Validation of the flare geometric analysis (FGA) and assessment of intraobserver and interobserver variability are investigated in this study. METHODS Two series of 3 BeGraft BECSs (Bentley InnoMed GmbH, Hechingen, Germany) and 1 series of 3 Advanta V12 BECSs (Getinge AB, Göteborg, Sweden) were deployed in 3 side branches (45°, 60°, and 90° aortic branch angles) of an aorta phantom model. A standard post-FEVAR CTA scan was acquired. Computed tomographic angiography-derived measurements consisted of centerline reconstructions and placement of 3-dimensional coordinate markers by 2 observers in a vascular workstation. Flare geometric analysis calculates 3 BECS parameters: the circumferential flare-to-fenestration distance (FFD), which is the distance from the proximal end of the flare to fenestration, and diameters at the proximal end of the flare (Dflare) and at the fenestration (Dfenestration). Computed tomographic angiography-derived measurements were validated against microscopy measurements. Bland-Altman plots were used to determine the intraobserver and interobserver variability of the BECS parameters and intraclass correlation coefficient (ICC). RESULTS For each BECS, the FFD at 4 equidistant quadrants of the circumference, Dflare, and Dfenestration were calculated. The mean difference and repeatability coefficient (RC) of the validation were 0.8 (2.1) mm for FFD, 0.4 (1.0) mm for Dflare, and -0.2 (1.2) mm for Dfenestration. The mean intraobserver and interobserver difference (RC) was 0.5 (1.6) mm and 0.7 (2.6) mm for FFD, 0.1 (0.6) mm and 0.1 (0.7) mm for Dflare, and -0.1 (0.8) mm and -0.8 (1.0) mm for Dfenestration. The mean ICC of intraobserver variability was 0.86 for FFD, 0.94 for Dflare, and 0.78 for Dfenestration. The mean ICC of interobserver variability was 0.77 for FFD, 0.92 for Dflare, and 0.48 for Dfenestration. CONCLUSION This study showed that FGA of the flared ends of BECS can be performed with high accuracy in a phantom model, with good intraobserver and interobserver variability. Flare geometric analysis can be used to determine flare geometry of the BECS on standard post-FEVAR CTA scans.
Collapse
Affiliation(s)
- Claire van der Riet
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Richte C L Schuurmann
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.,Multimodality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Reinoud P H Bokkers
- Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Fenna A van der Zijden
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Ignace F J Tielliu
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Cornelis H Slump
- Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), Robotics and Mechatronics (RAM), University of Twente, Enschede, The Netherlands
| | - Jean-Paul P M de Vries
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
7
|
Avril S, Gee MW, Hemmler A, Rugonyi S. Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3529. [PMID: 34490740 DOI: 10.1002/cnm.3529] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 08/30/2021] [Indexed: 06/13/2023]
Abstract
Endovascular aortic repair (EVAR) has become the preferred intervention option for aortic aneurysms and dissections. This is because EVAR is much less invasive than the alternative open surgery repair. While in-hospital mortality rates are smaller for EVAR than open repair (1%-2% vs. 3%-5%), the early benefits of EVAR are lost after 3 years due to larger rates of complications in the EVAR group. Clinicians follow instructions for use (IFU) when possible, but are left with personal experience on how to best proceed and what choices to make with respect to stent-graft (SG) model choice, sizing, procedural options, and their implications on long-term outcomes. Computational modeling of SG deployment in EVAR and tissue remodeling after intervention offers an alternative way of testing SG designs in silico, in a personalized way before intervention, to ultimately select the strategies leading to better outcomes. Further, computational modeling can be used in the optimal design of SGs in cases of complex geometries. In this review, we address some of the difficulties and successes associated with computational modeling of EVAR procedures. There is still work to be done in all areas of EVAR in silico modeling, including model validation, before models can be applied in the clinic, but much progress has already been made. Critical to clinical implementation are current efforts focusing on developing fast algorithms that can achieve (near) real-time solutions, as well as ways of dealing with inherent uncertainties related to patient aortic wall degradation on an individualized basis. We are optimistic that EVAR modeling in the clinic will soon become a reality to help clinicians optimize EVAR interventions and ultimately reduce EVAR-associated complications.
Collapse
Affiliation(s)
- Stéphane Avril
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, Saint-Étienne, France
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - André Hemmler
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - Sandra Rugonyi
- Biomedical Engineering Department, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
8
|
Huang CY, Chen PL, Lu HY, Hsu HL, Kuo TT, Chen IM, Hsu CP, Shih CC. Midterm result of custom-made iliac branch device for common iliac aneurysm with and without abdominal aortic aneurysm. Interact Cardiovasc Thorac Surg 2021; 32:97-105. [PMID: 33346345 DOI: 10.1093/icvts/ivaa229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Revised: 08/18/2020] [Accepted: 09/04/2020] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES Although commercial iliac branch devices offer a new and valid endovascular approach to treating iliac aneurysm and effectively preserve antegrade flow of the internal iliac artery, their use may not be suited for all types of challenging anatomy, especially isolated common iliac artery aneurysm. Our custom-made iliac bifurcation device has a unique design and excludes both combined and isolated iliac branch aneurysm. This study validated the efficacy and safety of the custom device by comparing clinical outcomes between groups receiving commercial and custom devices. METHODS Data of consecutive patients receiving iliac bifurcation device implantation for iliac aneurysm with or without concomitant endovascular repair for abdominal aortic aneurysm from January 2010 to May 2019 were reviewed. RESULTS Iliac bifurcation device implantation with or without concomitant abdominal aortic aneurysm stent grafting was completed in 46 patients (commercial, n = 35; custom, n = 11). No significant differences were observed regarding postoperative complications, occlusion or endoleak. Comparisons of primary (80.8% vs 85.7%, P = 0.88) and secondary (86.5% vs 85.7%, P = 0.85) patency and freedom from reintervention (88.2% vs 100%, P = 0.33), all-cause mortality (78.6% vs 100%, P = 0.25) and aneurysm-related mortality (100% vs 100%, P = 1.00) also indicated no differences at a 5-year surveillance point. Furthermore, the iliac aneurysms of the groups displayed similar shrinkage 1 year after procedures. CONCLUSIONS For iliac aneurysm, the novel custom-made iliac bifurcation device is an adaptable design not inferior to commercial devices with regard to postoperative complications, bridge occlusion, endoleak and short-term aneurysm remodelling. It provides an alternative for treatment, particularly when certain anatomic challenges are present. CLINICAL TRIAL REGISTRATION 2018-07-050BC, 2017-01-023ACF.
Collapse
Affiliation(s)
- Chun-Yang Huang
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Po-Lin Chen
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Hsin-Ying Lu
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
- Division of Cardiovascular Surgery, Taipei Municipal Wanfang Hospital, Taipei, Taiwan
- Taipei Heart Institute, Taipei Medical University, Taipei, Taiwan
| | - Hung-Lung Hsu
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
- Division of Cardiovascular Surgery, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Tzu-Ting Kuo
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - I-Ming Chen
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Chiao-Po Hsu
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Chun-Che Shih
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Clinical Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
- Division of Cardiovascular Surgery, Taipei Municipal Wanfang Hospital, Taipei, Taiwan
- Taipei Heart Institute, Taipei Medical University, Taipei, Taiwan
| |
Collapse
|
9
|
Yoon WJ, Rodriguez VM, Lee CJ. Insights on Bridging Stent Grafts in Fenestrated and Branched Aortic Endografting. Vasc Specialist Int 2021; 37:14. [PMID: 34135130 PMCID: PMC8209487 DOI: 10.5758/vsi.210025] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/27/2021] [Accepted: 05/28/2021] [Indexed: 11/20/2022] Open
Abstract
Major branches of the aortic arch and visceral aorta pose a particular challenge for endovascular repair of aneurysms involving these regions. To preserve perfusion through these essential branches, fenestrated and branched endografts have been used. Current fenestrated and branched aortic endografts have evolved into modular devices in which the aortic main body provides appropriate access to the target branch vessel either through reinforced fenestrations or directional cuffs as the hinge point for bridging stent grafts (BSGs). BSGs are used to connect the aortic main body and target branch vessel, and must provide both unhindered flow and a seal. Appropriate selection of BSG for target vessels in branched and fenestrated endovascular aortic repair is critical for technical success and durability. At present, there are no dedicated devices for use as BSGs, and a variety of stent grafts are currently used off-label. In this report, we review the available published series on the performance of presently available BSGs in relation to their design and selection.
Collapse
Affiliation(s)
- William J Yoon
- Division of Vascular Surgery, Department of Surgery, University of California-Davis, Sacramento, CA, USA.,Section of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Victor M Rodriguez
- Division of Vascular Surgery, Department of Surgery, University of California-Davis, Sacramento, CA, USA.,Division of Cardiothoracic Surgery, Department of Surgery, University of California-Davis, Sacramento, CA, USA
| | - Cheong Jun Lee
- Division of Vascular Surgery, Department of Surgery, NorthShore University HealthSystem, University of Chicago Pritzker School of Medicine, Evanston, IL, USA
| |
Collapse
|
10
|
van der Riet C, Schuurmann RCL, Verhoeven ELG, Zeebregts CJ, Tielliu IFJ, Bokkers RPH, Katsargyris A, de Vries JPPM. Outcomes of Advanta V12 Covered Stents After Fenestrated Endovascular Aneurysm Repair. J Endovasc Ther 2021; 28:700-706. [PMID: 34008441 PMCID: PMC8438773 DOI: 10.1177/15266028211016423] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Purpose: Fenestrated endovascular aneurysm repair (FEVAR) is a well-established endovascular treatment option for pararenal abdominal aortic aneurysms in which balloon-expandable covered stents (BECS) are used to bridge the fenestration to the target vessels. This study presents midterm clinical outcomes and patency rates of the Advanta V12 BECS used as a bridging stent. Methods: All patients treated with FEVAR with at least 1 Advanta V12 BECS were included from 2 large-volume vascular centers between January 2012 and December 2015. Primary endpoints were freedom from all-cause reintervention, and freedom from BECS-associated complications and reintervention. BECS-associated complications included significant stenosis, occlusion, type 3 endoleak, or stent fracture. Secondary endpoints included all-cause mortality in-hospital and during follow-up. Results: This retrospective study included 194 FEVAR patients with a mean age of 72.2±8.0 years. A total of 457 visceral arteries were stented with an Advanta V12 BECS. Median (interquartile range) follow-up time was 24.6 (1.6, 49.9) months. The FEVAR procedure was technically successful in 93% of the patients. Five patients (3%) died in-hospital. Patient survival was 77% (95% CI 69% to 84%) at 3 years. Freedom from all-cause reintervention was 70% (95% CI 61% to 78%) at 3 years, and 33% of all-cause reinterventions were BECS associated. Complications were seen in 24 of 457 Advanta V12 BECSs: type 3 endoleak in 8 BECSs, significant stenosis in 4 BECSs, occlusion in 6 BECSs, and stent fractures in 3 BECSs. A combination of complications occurred in 3 BECSs: type 3 endoleak and stenosis, stent fracture and stenosis, and stent fracture and occlusion. The freedom from BECS-associated complications for Advanta V12 BECSs was 98% (95% CI 96% to 99%) at 1 year and 92% (95% CI 88% to 95%) at 3 years. The freedom from BECS-associated reinterventions was 98% (95% CI 95% to 100%) at 1 year and 94% (95% CI 91% to 97%) at 3 years. Conclusion: The Advanta V12 BECS used as bridging stent in FEVAR showed low complication and reintervention rates at 3 years. A substantial number of FEVAR patients required a reintervention, but most were not BECS related.
Collapse
Affiliation(s)
- Claire van der Riet
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Richte C L Schuurmann
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.,Multimodality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Eric L G Verhoeven
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, Nuremberg, Germany
| | - Clark J Zeebregts
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Ignace F J Tielliu
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Reinoud P H Bokkers
- Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, Nuremberg, Germany
| | - Jean-Paul P M de Vries
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| |
Collapse
|
11
|
Tran K, Yang W, Marsden A, Lee JT. Patient-specific computational flow modelling for assessing hemodynamic changes following fenestrated endovascular aneurysm repair. JVS Vasc Sci 2021; 2:53-69. [PMID: 34258601 PMCID: PMC8274562 DOI: 10.1016/j.jvssci.2020.11.032] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Objective This study aimed to develop an accessible patient-specific computational flow modelling pipeline for evaluating the hemodynamic performance of fenestrated endovascular aneurysm repair (fEVAR), with the hypothesis that computational flow modelling can detect aortic branch hemodynamic changes associated with fEVAR graft implantation. Methods Patients who underwent fEVAR for juxtarenal aortic aneurysms with the Cook ZFEN were retrospectively selected. Using open-source SimVascular software, preoperative and postoperative visceral aortic anatomy was manually segmented from computed tomography angiograms. Three-dimensional geometric models were then discretized into tetrahedral finite element meshes. Patient-specific pulsatile in-flow conditions were derived from known supraceliac aortic flow waveforms and adjusted for patient body surface area, average resting heart rate, and blood pressure. Outlet boundary conditions consisted of three-element Windkessel models approximated from physiologic flow splits. Rigid wall flow simulations were then performed on preoperative and postoperative models with the same inflow and outflow conditions. We used SimVascular's incompressible Navier-Stokes solver to perform blood flow simulations on a cluster using 72 cores. Results Preoperative and postoperative flow simulations were performed for 10 patients undergoing fEVAR with a total of 30 target vessels (20 renal stents, 10 mesenteric scallops). Postoperative models required a higher mean number of mesh elements to reach mesh convergence (3.2 ± 1.8 × 106 vs 2.6 ± 1.1 × 106; P = .005) with a longer mean computational time (10.3 ± 6.3 hours vs 7.8 ± 3.5 hours; P = .04) compared with preoperative models. fEVAR was associated with small but statistically significant increases in mean peak proximal aortic arterial pressure (140.3 ± 11.0 mm Hg vs 136.9 ± 8.7 mm Hg; P = .02) and peak renal artery pressure (131.6 ± 14.8 mm Hg vs 128.9 ± 11.8 mm Hg; P = .04) compared with preoperative simulations. No differences were observed in peak pressure in the celiac, superior mesenteric, or distal aortic arteries (P = .17-.96). When measuring blood flow, the only observed difference was an increase in peak renal flow rate after fEVAR (17.5 ± 3.8 mL/s vs 16.9 ± 3.5 mL/s; P = .04). fEVAR was not associated with changes in the mean pressure or the mean flow rate in the celiac, superior mesenteric, or renal arteries (P = .06-.98). Stenting of the renal arteries did not induce significant changes time-averaged wall shear stress in the proximal renal artery (23.4 ± 8.1 dynes/cm2 vs 23.2 ± 8.4 dynes/cm2; P = .98) or distal renal artery (32.7 ± 13.9 dynes/cm2 vs 29.6 ± 11.8 dynes/cm2; P = .23). In addition, computational visualization of cross-sectional velocity profiles revealed low flow disturbances associated with protrusion of renal graft fabric into the aortic lumen. Conclusions In a pilot study involving a selective cohort of patients who underwent uncomplicated fEVAR, patient-specific flow modelling was a feasible method for assessing the hemodynamic performance of various two-vessel fenestrated device configurations and revealed subtle differences in computationally derived peak branch pressure and blood flow rates. Structural changes in aortic flow geometry after fEVAR do not seem to affect computationally estimated renovisceral branch perfusion or wall shear stress adversely. Additional studies with invasive angiography or phase contrast magnetic resonance imaging are required to clinically validate these findings. (JVS–Vascular Science 2021;2:53-69.) Clinical Relevance Using a computational flow modelling for assessing the hemodynamic performance of fenestrated endovascular aneurysm repair (fEVAR), this real-world, patient-specific study included 10 participants and found that structural changes in aortic flow geometry after fEVAR did not seem to adversely impact estimated renal or visceral branch perfusion metrics (eg, peak and mean arterial pressure and flow rates) or wall shear stress. These findings overall support the ongoing clinical use of commercially available fEVAR devices for repair of juxtarenal aortic aneurysms, and provides a computational framework for future evaluation of fEVAR configurations in a preoperative or postoperative settings.
Collapse
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford University.,Cardiovascular Institute, Stanford University
| | - Weiguang Yang
- Department of Pediatrics (Cardiology), Stanford University
| | - Alison Marsden
- Department of Pediatrics (Cardiology), Stanford University.,Department of Bioengineering, Stanford University
| | - Jason T Lee
- Division of Vascular Surgery, Stanford University.,Cardiovascular Institute, Stanford University
| | | |
Collapse
|
12
|
Zhu Y, Zhan W, Hamady M, Xu XY. A pilot study of aortic hemodynamics before and after thoracic endovascular repair with a double-branched endograft. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2019. [DOI: 10.1016/j.medntd.2020.100027] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
13
|
Hemodynamic analysis of a novel stent graft design with slit perforations in thoracic aortic aneurysm. J Biomech 2019; 85:210-217. [DOI: 10.1016/j.jbiomech.2019.01.019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Revised: 12/08/2018] [Accepted: 01/08/2019] [Indexed: 01/11/2023]
|