Jermain PR, Muir B, McEwen M, Niu Y, Pang D. Accurate machine-specific reference and small-field dosimetry for a self-shielded neuro-radiosurgical system. Med Phys 2024; 51:4423-4433. [PMID: 38695760 DOI: 10.1002/mp.17111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 03/14/2024] [Accepted: 04/18/2024] [Indexed: 06/05/2024] Open
Abstract
BACKGROUND The newly available ZAP-X stereotactic radiosurgical system is designed for the treatment of intracranial lesions, with several unique features that include a self-shielding, gyroscopic gantry, wheel collimation, non-orthogonal kV imaging, short source-axis distance, and low-energy megavoltage beam. Systematic characterization of its radiation as well as other properties is imperative to ensure its safe and effective clinical application. PURPOSE To accurately determine the radiation output of the ZAP-X with a special focus on the smaller diameter cones and an aim to provide useful recommendations on quantification of small field dosimetry. METHODS Six different types of detectors were used to measure relative output factors at field sizes ranging from 4 to 25 mm, including the PTW microSilicon and microdiamond diodes, Exradin W2 plastic scintillator, Exradin A16 and A1SL ionization chambers, and the alanine dosimeter. The 25 mm cone served as the reference field size. Absolute dose was determined with both TG-51-based dosimetry using a calibrated PTW Semiflex ion chamber and measurements using alanine dosimeters. RESULTS The average radiation output factors (maximum deviation from the average) measured with the microDiamond, microSilicon, and W2 detectors were: for the 4 mm cone, 0.741 (1.0%); for the 5 mm cone: 0.817 (1.0%); for the 7.5 mm cone: 0.908 (1.0%); for the 10 mm cone: 0.946 (0.4%); for the 12.5 mm cone: 0.964 (0.2%); for the 15 mm cone: 0.976 (0.1%); for the 20 mm cone: 0.990 (0.1%). For field sizes larger than 10 mm, the A1SL and A16 micro-chambers also yielded consistent output factors within 1.5% of those obtained using the microSilicon, microdiamond, and W2 detectors. The absolute dose measurement obtained with alanine was within 1.2%, consistent with combined uncertainties, compared to the PTW Semiflex chamber for the 25 mm reference cone. CONCLUSION For field sizes less than 10 mm, the microSilicon diode, microDiamond detector, and W2 scintillator are suitable devices for accurate small field dosimetry of the ZAP-X system. For larger fields, the A1SL and A16 micro-chambers can also be used. Furthermore, alanine dosimetry can be an accurate verification of reference and absolute dose typically measured with ion chambers. Use of multiple suitable detectors and uncertainty analyses were recommended for reliable determination of small field radiation outputs.
Collapse
Affiliation(s)
- Peter R Jermain
- Department of Radiation Medicine, Medstar Georgetown University Hospital, Washington, District of Columbia, USA
| | - Bryan Muir
- Metrology Research Centre, National Research Council, Ottawa, Ontario, Canada
| | - Malcolm McEwen
- Metrology Research Centre, National Research Council, Ottawa, Ontario, Canada
| | - Ying Niu
- Department of Radiation Medicine, Medstar Georgetown University Hospital, Washington, District of Columbia, USA
| | - Dalong Pang
- Department of Radiation Medicine, Medstar Georgetown University Hospital, Washington, District of Columbia, USA
| |
Collapse
|
2
|
Tang JD, Mills MN, Nakashima J, Dohm AE, Khushalani NI, Forsyth PA, Vogelbaum MA, Wuthrick EJ, Yu HHM, Oliver DE, Liu JKC, Ahmed KA. Clinical outcomes of melanoma brain metastases treated with nivolumab and ipilimumab alone versus nivolumab and ipilimumab with stereotactic radiosurgery. J Neurooncol 2024; 166:431-440. [PMID: 38310157 DOI: 10.1007/s11060-023-04543-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 12/13/2023] [Indexed: 02/05/2024]
Abstract
PURPOSE Upfront dual checkpoint blockade with immune checkpoint inhibitors (ICI) has demonstrated efficacy for treating melanoma brain metastases (MBM) in asymptomatic patients. Whether the combination of stereotactic radiosurgery (SRS) with dual checkpoint blockade improves outcomes over dual-checkpoint blockade alone is unknown. We evaluated clinical outcomes of patients with MBM receiving ICI with nivolumab and ipilimumab, with and without SRS. METHODS 49 patients with 158 MBM receiving nivolumab and ipilimumab for untreated MBM between 2015 and 2022 were identified at our institution. Patient and tumor characteristics including age, Karnofsky Performance Status (KPS), presence of symptoms, cancer history, MBM burden, and therapy course were recorded. Outcomes measured from initiation of MBM-directed therapy included overall survival (OS), local control (LC), and distant intracranial control (DIC). Time-to-event analysis was conducted with the Kaplan-Meier method. RESULTS 25 patients with 74 MBM received ICI alone, and 24 patients with 84 MBM received concurrent SRS. Median follow-up was 24 months. No differences in age (p = 0.96), KPS (p = 0.85), presence of symptoms (p = 0.79), prior MBM (p = 0.68), prior MBM-directed surgery (p = 0.96) or SRS (p = 0.68), MBM size (p = 0.67), or MBM number (p = 0.94) were seen. There was a higher rate of nivolumab and ipilimumab course completion in the SRS group (54% vs. 24%; p = 0.029). The SRS group received prior immunotherapy more often than the ICI alone group (54% vs. 8.0%; p < 0.001). There was no significant difference in 1-year OS (72% vs. 71%, p = 0.20) and DIC (63% v 51%, p = 0.26) between groups. The SRS group had higher 1-year LC (92% vs. 64%; p = 0.002). On multivariate analysis, LC was improved with combination therapy (AHR 0.38, p = 0.01). CONCLUSION In our analysis, patients who received SRS with nivolumab and ipilimumab had superior LC without increased risk of toxicity or compromised immunotherapy treatment completion despite the SRS cohort having higher rates of prior immunotherapy. Further prospective study of combination nivolumab and ipilimumab with SRS is warranted.
Collapse
Affiliation(s)
- Joseph D Tang
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - Matthew N Mills
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - Justyn Nakashima
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - Ammoren E Dohm
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - Nikhil I Khushalani
- Department of Cutaneous Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, USA
| | - Peter A Forsyth
- Department of Neuro-Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, USA
| | - Michael A Vogelbaum
- Department of Neuro-Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, USA
| | - Evan J Wuthrick
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - Hsiang-Hsuan M Yu
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - Daniel E Oliver
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA
| | - James K C Liu
- Department of Neuro-Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, USA
| | - Kamran A Ahmed
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, 12902 Magnolia Dr. , Tampa, FL, USA.
| |
Collapse
|
3
|
Szewczyk B, Tarasek M, Campwala Z, Trowbridge R, Zhao Z, Johansen PM, Olmsted Z, Bhushan C, Fiveland E, Ghoshal G, Heffter T, Tavakkolmoghaddam F, Bales C, Wang Y, Rajamani DK, Gandomi K, Nycz C, Jeannotte E, Mane S, Nalwalk J, Burdette EC, Fischer G, Yeo D, Qian J, Pilitsis J. What happens to brain outside the thermal ablation zones? An assessment of needle-based therapeutic ultrasound in survival swine. Int J Hyperthermia 2022; 39:1283-1293. [PMID: 36162814 DOI: 10.1080/02656736.2022.2126901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
Abstract
BACKGROUND In stereotactic radiosurgery, isodose lines must be considered to determine how surrounding tissue is affected. In thermal ablative therapy, such as laser interstitial thermal therapy (LITT), transcranial MR-guided focused ultrasound (tcMRgFUS), and needle-based therapeutic ultrasound (NBTU), how the surrounding area is affected has not been well studied. OBJECTIVE We aimed to quantify the transition zone surrounding the ablation core created by magnetic resonance-guided robotically-assisted (MRgRA) delivery of NBTU using multi-slice volumetric 2-D magnetic resonance thermal imaging (MRTI) and subsequent characterization of the resultant tissue damage using histopathologic analysis. METHODS Four swine underwent MRgRA NBTU using varying duration and wattage for treatment delivery. Serial MRI images were obtained, and the most representative were overlaid with isodose lines and compared to brain tissue acquired postmortem which underwent histopathologic analysis. These results were also compared to predicted volumes using a finite element analysis model. Contralateral brain tissue was used for control data. RESULTS Intraoperative MRTI thermal isodose contours were characterized and comprehensively mapped to post-operative MRI images and qualitatively compared with histological tissue sections postmortem. NBTU 360° ablations induced smaller lesion volumes (33.19 mm3; 120 s, 3 W; 30.05 mm3, 180 s, 4 W) versus 180° ablations (77.20 mm3, 120 s, 3 W; 109.29 mm3; 180 s; 4 W). MRTI/MRI overlay demonstrated the lesion within the proximal isodose lines. The ablation-zone was characterized by dense macrophage infiltration and glial/neuronal loss as demonstrated by glial fibrillary acidic protein (GFAP) and neurofilament (NF) absence and avid CD163 staining. The transition-zone between lesion and normal brain demonstrated decreased macrophage infiltration and measured ∼345 microns (n - 3). We did not detect overt hemorrhages or signs of edema in the adjacent spared tissue. CONCLUSION We successfully performed MRgRA NBTU ablation in swine and demonstrated minimal histologic changes extended past the ablation-zone. The lesion was characterized by macrophage infiltration and glial/neuronal loss which decreased through the transition-zone.
Collapse
Affiliation(s)
- Benjamin Szewczyk
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.,Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | | | - Zahabiya Campwala
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Rachel Trowbridge
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Zhanyue Zhao
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Phillip M Johansen
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | - Zachary Olmsted
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | | | | | | | | | | | - Charles Bales
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Yang Wang
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Dhruv Kool Rajamani
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Katie Gandomi
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Christopher Nycz
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Erin Jeannotte
- Animal Resources Facility, Albany Medical Center, Albany, NY, USA
| | - Shweta Mane
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Julia Nalwalk
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | | | - Gregory Fischer
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Desmond Yeo
- GE Global Research Center, Niskayuna, NY, USA
| | - Jiang Qian
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.,Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Julie Pilitsis
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.,Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA.,Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| |
Collapse
|
4
|
A deep neural network-based model predicting peritumoral edema after radiosurgery for meningioma. World Neurosurg 2022; 164:e280-e289. [DOI: 10.1016/j.wneu.2022.04.125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 04/22/2022] [Accepted: 04/23/2022] [Indexed: 11/18/2022]
|
5
|
Saw CB, Battin F, McKeague J, Haggerty M, Baikadi M, Peters C. Dose planning management of patients undergoing salvage whole brain radiation therapy after radiosurgery. Med Dosim 2016; 41:277-280. [DOI: 10.1016/j.meddos.2016.05.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 05/19/2016] [Indexed: 11/28/2022]
|
6
|
Schönthal AH. Antitumor properties of dimethyl-celecoxib, a derivative of celecoxib that does not inhibit cyclooxygenase-2: implications for glioma therapy. Neurosurg Focus 2006; 20:E21. [PMID: 16709027 DOI: 10.3171/foc.2006.20.4.14] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
✓ Celecoxib (Celebrex) appears to be unique among the class of selective COX-2 inhibitors (coxibs), because this particular compound exerts a second function that is independent of its celebrated ability to inhibit COX-2. This second function is the potential to inhibit cell proliferation and stimulate apoptotic cell death at much lower concentrations than any other coxibs. Intriguingly, these two functions are mediated by different moieties of the celecoxib molecule and can be separated. The author, as well as others, have generated and investigated analogs of celecoxib that retain only one of these two functions. One derivative, 2,5-dimethyl-celecoxib (DMC), which retains the antiproliferative and apoptosis-inducing function, but completely lacks the COX-2 inhibitory activity, is able to mimic faithfully all of the numerous antitumor effects of celecoxib that have been investigated so far, including reduction of neovascularization and inhibition of experimental tumor growth in various in vivo tumor models. In view of the controversy that has recently arisen regarding the life-threatening side effects of this class of coxibs, it may be worthwhile to pursue further the potential benefits of drugs such as DMC for anticancer therapy. Because DMC is not a coxib yet potently maintains celecoxib's antitumor potential, one may be inclined to speculate that this novel compound could potentially be advantageous in the management of COX-2–independent cancers. In this summary, the implications of recent findings with DMC will be presented and discussed.
Collapse
Affiliation(s)
- Axel H Schönthal
- Department of Molecular Microbiology and Immunology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
| |
Collapse
|
7
|
Shah GD, Kesari S, Xu R, Batchelor TT, O’Neill AM, Hochberg FH, Levy B, Bradshaw J, Wen PY. Comparison of linear and volumetric criteria in assessing tumor response in adult high-grade gliomas. Neuro Oncol 2006; 8:38-46. [PMID: 16443946 PMCID: PMC1871928 DOI: 10.1215/s1522851705000529] [Citation(s) in RCA: 150] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
The Response Evaluation Criteria in Solid Tumors, or RECIST criteria (one-dimensional [1D] measurement), are widely used to measure response in tumors, but there are few studies evaluating these criteria in brain tumors. We compared linear and volumetric measurements in adult high-grade supratentorial enhancing gliomas to determine the agreement between measurements, in defining responses and in their subsequent relation to survival. We hypothesized that the 1D RECIST criteria maybe suitable for response assessment in adult high-grade gliomas. Tumor size on MRI scans in 104 patients with high-grade enhancing gliomas treated on clinical trial protocols was measured by using 1D (greatest length), 2D (two-dimensional: product of the two longest perpendicular diameters), 3D (three dimensional: product of the longest perpendicular diameters in one plane and the longest orthogonal diameter to that plane), enhancing volume (EV), and total volume (TV). A total of 388 T1 postgadolinium MRI scans (104 baseline and 284 follow-up scans) were evaluated. Volumetric analysis (EV and TV) was performed with commercially available software. Intraobserver and interobserver correlations (rho) were high for all modalities (rho > 0.92 and rho > 0.71, respectively). Correlation was excellent (rho > 0.9) among all modalities except for 3D (rho < 0.6). Patient response rates ranged from 12% to 26%. Median progression-free survival (mPFS) and six-month progression-free survival (6mPFS) were not significantly different among the methods (range, 5.3 months to 5.9 months and 42% to 48%, respectively). Landmark analyses of response at two months using linear methods predicted overall survival with hazard ratios of 0.19 to 0.29 (P < 0.005). These results suggest high concordance among 1D, 2D, TV, and EV, but not 3D, methods in assessing enhancing tumor progression and in estimating mPFS and 6mPFS in adult brain tumor patients. The tumor response at two months assessed by linear methods correlated better with overall survival. Thus, linear methods are comparable to volumetric methods, but simpler to implement for routine clinical use and for designing clinical trials of brain tumors.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Patrick Y. Wen
- Address correspondence to Patrick Y. Wen, Center for Neuro-Oncology, Dana-Farber Cancer Institute and Division of Neuro-Oncology, Department of Neurology, Brigham and Women’s Hospital, SW430D, 44 Binney Street, Boston, MA 02115, USA (
)
| |
Collapse
|