Three Dimensional Lifetime-Multiplex Tomography Based on Time-Gated Capturing of Near-Infrared Fluorescence Images. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
We report a computed tomography (CT) technique for mapping near-infrared fluorescence (NIRF) lifetime as a multiplex three-dimensional (3D) imaging method, using a conventional NIR camera. This method is achieved by using a time-gated system composed of a pulsed laser and an NIR camera synchronized with a rotatable sample stage for NIRF-CT imaging. The fluorescence lifetimes in microsecond-order of lanthanides were mapped on reconstructed cross-sectional and 3D images, via back-projection of two-dimensional projected images acquired from multiple angles at each time point showing fluorescence decay. A method to select slopes (the observed decay rates in time-gated imaging) used for the lifetime calculation, termed as the slope comparison method, was developed for the accurate calculation of each pixel, resulting in reduction of image acquisition time. Time-gated NIRF-CT provides a novel choice for multiplex 3D observation of deep tissues in biology.
Collapse
|
2
|
Takematsu M, Umezawa M, Sera T, Kitagawa Y, Kurahashi H, Yamada S, Okubo K, Kamimura M, Yokota H, Soga K. Influence of the difference in refractive index on the interface of an object and the surroundings in near-infrared fluorescence tomography. APPLIED OPTICS 2022; 61:638-644. [PMID: 35200907 DOI: 10.1364/ao.445357] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 12/03/2021] [Indexed: 06/14/2023]
Abstract
The refraction of fluorescence from the inside of a sample at the surface results in fluctuations in fluorescence computed tomography (CT). We evaluated the influence of the difference in refractive index (RI) between the sample body and the surroundings on fluorescence CT results. The brightest fluorescent point is away from the correct point on the tomograms owing to the refraction. The speculated position is determined as the exact point if the RI ratio ranges between 0.97 and 1.03 by immersing the body in an RI matching liquid. The results can help in experimental settings of fluorescence CT for acquiring three-dimensional positional information.
Collapse
|
3
|
Liang X, Chen M, Bhattarai P, Hameed S, Dai Z. Perfluorocarbon@Porphyrin Nanoparticles for Tumor Hypoxia Relief to Enhance Photodynamic Therapy against Liver Metastasis of Colon Cancer. ACS NANO 2020; 14:13569-13583. [PMID: 32915537 DOI: 10.1021/acsnano.0c05617] [Citation(s) in RCA: 113] [Impact Index Per Article: 28.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Photodynamic therapy (PDT) shows great promise for the treatment of colon cancer. However, practically, it is a great challenge to use a nanocarrier for the codelivery of both the photosensitizer and oxygen to improve PDT against PDT-induced hypoxia, which is closely related to tumor metastasis. Hence, an effective strategy was proposed to develop an oxygen self-supplemented PDT nanocarrier based on the ultrasonic dispersion of perfluorooctyl bromide (PFOB) liquid into the preformed porphyrin grafted lipid (PGL) nanoparticles (NPs) with high porphyrin loading content of 38.5%, followed by entrapping oxygen. Interestingly, the orderly arranging mode of porphyrins and alkyl chains in PGL NPs not only guarantees a high efficacy of singlet oxygen generation but also reduces fluorescence loss of porphyrins to enable PGL NPs to be highly fluorescent. More importantly, PFOB liquid was stabilized inside PGL NPs with an ultrahigh loading content of 98.15% due to the strong hydrophobic interaction between PGL and PFOB molecules, facilitating efficient oxygen delivery. Both in vitro and in vivo results demonstrated that the obtained O2@PFOB@PGL NPs could act as a prominent oxygen reservoir and effectively replenish oxygen into the hypoxic tumors with no need for external stimulation, conducive to augmented singlet oxygen generation, hypoxia relief, and subsequent downregulation of COX-2 expression. As a result, the use of O2@PFOB@PGL NPs for hypoxia relief dramatically inhibits tumor growth and liver metastasis in an HT-29 colon cancer mouse model. In addition, the O2@PFOB@PGL NPs could serve as a bimodal contrast agent to enhance fluorescence and CT imaging, visualizing nanoparticle accumulation to guide the subsequent laser irradiation for precise PDT.
Collapse
Affiliation(s)
- Xiaolong Liang
- Department of Ultrasound, Peking University Third Hospital, Beijing 100191, China
| | - Min Chen
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Pravin Bhattarai
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Sadaf Hameed
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Zhifei Dai
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
4
|
Daly MJ, Chan H, Muhanna N, Akens MK, Wilson BC, Irish JC, Jaffray DA. Intraoperative cone-beam CT spatial priors for diffuse optical fluorescence tomography. ACTA ACUST UNITED AC 2019; 64:215007. [DOI: 10.1088/1361-6560/ab4917] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
5
|
A Novel Mouse Segmentation Method Based on Dynamic Contrast Enhanced Micro-CT Images. PLoS One 2017; 12:e0169424. [PMID: 28060917 PMCID: PMC5217965 DOI: 10.1371/journal.pone.0169424] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Accepted: 12/17/2016] [Indexed: 11/22/2022] Open
Abstract
With the development of hybrid imaging scanners, micro-CT is widely used in locating abnormalities, studying drug metabolism, and providing structural priors to aid image reconstruction in functional imaging. Due to the low contrast of soft tissues, segmentation of soft tissue organs from mouse micro-CT images is a challenging problem. In this paper, we propose a mouse segmentation scheme based on dynamic contrast enhanced micro-CT images. With a homemade fast scanning micro-CT scanner, dynamic contrast enhanced images were acquired before and after injection of non-ionic iodinated contrast agents (iohexol). Then the feature vector of each voxel was extracted from the signal intensities at different time points. Based on these features, the heart, liver, spleen, lung, and kidney could be classified into different categories and extracted from separate categories by morphological processing. The bone structure was segmented using a thresholding method. Our method was validated on seven BALB/c mice using two different classifiers: a support vector machine classifier with a radial basis function kernel and a random forest classifier. The results were compared to manual segmentation, and the performance was assessed using the Dice similarity coefficient, false positive ratio, and false negative ratio. The results showed high accuracy with the Dice similarity coefficient ranging from 0.709 ± 0.078 for the spleen to 0.929 ± 0.006 for the kidney.
Collapse
|
6
|
Mohajerani P, Ntziachristos V. An Inversion Scheme for Hybrid Fluorescence Molecular Tomography Using a Fuzzy Inference System. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:381-390. [PMID: 26340771 DOI: 10.1109/tmi.2015.2475356] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The imaging performance of fluorescence molecular tomography (FMT) improves when information from the underlying anatomy is incorporated into the inversion scheme, in the form of priors. The requirement for incorporation of priors has recently driven the development of hybrid FMT systems coupled to other modalities, such as X-ray CT and MRI. A critical methodological aspect in this modality relates to the particular method selected to incorporate prior information obtained from the anatomical imaging modality into the FMT inversion. We propose herein a new approach for utilizing prior information, which preferentially minimizes residual errors associated with measurements that better describe the anatomical segments considered. This preferential minimization was realized using a weighted least square (WLS) approach, where the weights were optimized using a Mamdani-type fuzzy inference system. The method of priors introduced herein was deployed as a two-step structured regularization approach and was verified with experimental measurements from phantoms as well as ex vivo and in vivo animal studies. The results demonstrate accurate performance and minimization of reconstruction bias, without requiring user input for setting the regularization parameters. As such, the proposed method offers significant progress in incorporation of anatomical priors in FMT and, as a result, in realization of the full potential of hybrid FMT.
Collapse
|
7
|
Darne C, Lu Y, Sevick-Muraca EM. Small animal fluorescence and bioluminescence tomography: a review of approaches, algorithms and technology update. Phys Med Biol 2013; 59:R1-64. [PMID: 24334634 DOI: 10.1088/0031-9155/59/1/r1] [Citation(s) in RCA: 116] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Emerging fluorescence and bioluminescence tomography approaches have several common, yet several distinct features from established emission tomographies of PET and SPECT. Although both nuclear and optical imaging modalities involve counting of photons, nuclear imaging techniques collect the emitted high energy (100-511 keV) photons after radioactive decay of radionuclides while optical techniques count low-energy (1.5-4.1 eV) photons that are scattered and absorbed by tissues requiring models of light transport for quantitative image reconstruction. Fluorescence imaging has been recently translated into clinic demonstrating high sensitivity, modest tissue penetration depth, and fast, millisecond image acquisition times. As a consequence, the promise of quantitative optical tomography as a complement of small animal PET and SPECT remains high. In this review, we summarize the different instrumentation, methodological approaches and schema for inverse image reconstructions for optical tomography, including luminescence and fluorescence modalities, and comment on limitations and key technological advances needed for further discovery research and translation.
Collapse
|
8
|
Correia T, Ducros N, D'Andrea C, Schweiger M, Arridge S. Quantitative fluorescence diffuse optical tomography in the presence of heterogeneities. OPTICS LETTERS 2013; 38:1903-5. [PMID: 23722784 DOI: 10.1364/ol.38.001903] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
In fluorescence diffuse optical tomography (fDOT), the accuracy of reconstructed fluorescence distributions highly depends on the knowledge of the tissue optical heterogeneities for correct modeling of light propagation. Common approaches are to assume homogeneous optical properties or, when structural information is available, assign optical properties to various segmented organs, which is likely to result in inaccurate reconstructions. Furthermore, DOT based only on intensity (continuous wave-DOT) is a nonunique inverse problem, and hence, cannot be used to retrieve simultaneously maps of absorption and diffusion coefficients. We propose a method that reconstructs a single parameter from the excitation measurements, which is used in the fDOT problem to accurately recover fluorescence distribution.
Collapse
Affiliation(s)
- Teresa Correia
- Department of Computer Science, University College London, Gower Street, London WC1E 6BT, UK.
| | | | | | | | | |
Collapse
|
9
|
Huang H, Dunne M, Lo J, Jaffray DA, Allen C. Comparison of Computed Tomography– and Optical Image–Based Assessment of Liposome Distribution. Mol Imaging 2013. [DOI: 10.2310/7290.2012.00028] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Affiliation(s)
- Huang Huang
- From the Leslie Dan Faculty of Pharmacy, Departments of Medical Biophysics and Radiation Oncology, and Institute of Biomaterials and Biomedical Engineering, University of Toronto, and STTARR Innovation Centre and Techna and Ontario Cancer Institutes, Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, ON
| | - Michael Dunne
- From the Leslie Dan Faculty of Pharmacy, Departments of Medical Biophysics and Radiation Oncology, and Institute of Biomaterials and Biomedical Engineering, University of Toronto, and STTARR Innovation Centre and Techna and Ontario Cancer Institutes, Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, ON
| | - John Lo
- From the Leslie Dan Faculty of Pharmacy, Departments of Medical Biophysics and Radiation Oncology, and Institute of Biomaterials and Biomedical Engineering, University of Toronto, and STTARR Innovation Centre and Techna and Ontario Cancer Institutes, Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, ON
| | - David A. Jaffray
- From the Leslie Dan Faculty of Pharmacy, Departments of Medical Biophysics and Radiation Oncology, and Institute of Biomaterials and Biomedical Engineering, University of Toronto, and STTARR Innovation Centre and Techna and Ontario Cancer Institutes, Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, ON
| | - Christine Allen
- From the Leslie Dan Faculty of Pharmacy, Departments of Medical Biophysics and Radiation Oncology, and Institute of Biomaterials and Biomedical Engineering, University of Toronto, and STTARR Innovation Centre and Techna and Ontario Cancer Institutes, Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, ON
| |
Collapse
|
10
|
Solomon M, Nothdruft RE, Akers W, Edwards WB, Liang K, Xu B, Suddlow GP, Deghani H, Tai YC, Eggebrecht AT, Achilefu S, Culver JP. Multimodal fluorescence-mediated tomography and SPECT/CT for small-animal imaging. J Nucl Med 2013; 54:639-46. [PMID: 23447655 DOI: 10.2967/jnumed.112.105742] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED Spatial and temporal coregistration of nuclear and optical images can enable the fusion of the information from these complementary molecular imaging modalities. A critical challenge is in integrating the optical and nuclear imaging hardware. Flexible fiber-based fluorescence-mediated tomography (FMT) systems provide a viable solution. The various bore sizes of small-animal nuclear imaging systems can potentially accommodate the FMT fiber imaging arrays. In addition, FMT imaging facilitates coregistration of the nuclear and optical contrasts in time. Herein, we combine a fiber-based FMT system with a preclinical SPECT/CT platform. Feasibility of in vivo imaging is demonstrated by tracking a monomolecular multimodal imaging agent (MOMIA) during transport from the forepaw to the axillary lymph node region of a rat. METHODS The fiber-based, video-rate FMT imaging system is composed of 12 sources (785- and 830-nm laser diodes) and 13 detectors. To maintain high temporal sampling, the system simultaneously acquires ratio-metric data at each detector. A 3-dimensional finite element model derived from CT projections provides anatomically based light propagation modeling. Injection of a MOMIA intradermally into the forepaw of rats provided spatially and temporally coregistered nuclear and optical contrasts. FMT data were acquired concurrently with SPECT and CT data. The incorporation of SPECT data as a priori information in the reconstruction of FMT data integrated both optical and nuclear contrasts. RESULTS Accurate depth localization of phantoms with different thicknesses was accomplished with an average center-of-mass error of 4.1 ± 2.1 mm between FMT and SPECT measurements. During in vivo tests, fluorescence and radioactivity from the MOMIA were colocalized in spatially coincident regions with an average center-of-mass error of 2.68 ± 1.0 mm between FMT and SPECT for axillary lymph node localization. Intravital imaging with surgical exposure of the lymph node validated the localization of the optical contrast. CONCLUSION The feasibility of integrating a fiber-based, video-rate FMT system with a commercial preclinical SPECT/CT platform was established. These coregistered FMT and SPECT/CT results with MOMIAs may facilitate the development of the next generation of preclinical and clinical multimodal optical-nuclear platforms for a broad array of imaging applications and help elucidate the underlying biologic processes relevant to cancer diagnosis and therapy monitoring.
Collapse
Affiliation(s)
- Metasebya Solomon
- Department of Biomedical Engineering, Washington University, St. Louis, MO 63110, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Tan Y, Cao Z, Sajja HK, Lipowska M, Wang YA, Yang L, Jiang H. DOT corrected fluorescence molecular tomography using targeted contrast agents for small animal tumor imaging. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2013; 21:43-52. [PMID: 23507851 PMCID: PMC3785613 DOI: 10.3233/xst-130365] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
PURPOSE To demonstrate diffuse optical tomography (DOT) corrected fluorescence molecular tomography (FMT) for quantitatively imaging tumor-targeted contrast agents in a 4T1 mouse mammary tumor model. PROCEDURES In the first set of experiments, we validated our DOT corrected FMT method using subcutaneously injected 4T1 cells pre-labeled with a near-infrared (NIR) Cy 5.5 dye labeled recombinant amino-terminal fragment (ATF) of the receptor binding domain of urokinase plasminogen activator (uPA), which binds to uPA receptor (uPAR) that is highly expressed in breast cancer tissues. Next, we apply the DOT corrected FMT method to quantitatively evaluate the ability of sensitive tumor imaging after systemic delivery of new uPAR-targeted optical imaging probes in the mice bearing 4T1 mammary tumors. These uPAR-targeted optical imaging probes are ATF peptides labeled with a newly developed NIR-830 dye being conjugated to magnetic iron oxide nanoparticles (IONPs). RESULTS Our results have shown that DOT corrected FMT can accurately quantify and localize the injected imaging probe labeled 4T1 cells. Following systemic delivery of the targeted imaging nanoprobes into the mice bearing orthotopic mammary tumors, specific accumulation of the imaging probes in the orthotopic mammary tumors was detected in the mice that received uPAR targeted NIR-830-ATF-IONP probes but not in the mice injected with non-targeted NIR-830-mouse serum albumin (MSA)-IONPs. Additionally, DOT corrected FMT also enables the detection of both locally recurrent tumor and lung metastasis in the mammary tumor model 72 hrs after systemic administration of the uPAR-targeted NIR-830-labeled ATF peptide imaging probes. CONCLUSIONS DOT corrected FMT and uPAR-targeted optical imaging probes have great potential for detection of breast cancer, recurrent tumor and metastasis in small animals.
Collapse
Affiliation(s)
- Yiyong Tan
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Zehong Cao
- Departments of Surgery, Emory University, Atlanta, GA, USA
| | | | | | | | - Lily Yang
- Departments of Surgery, Emory University, Atlanta, GA, USA
| | - Huabei Jiang
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| |
Collapse
|
12
|
Darne CD, Lu Y, Tan IC, Zhu B, Rasmussen JC, Smith AM, Yan S, Sevick-Muraca EM. A compact frequency-domain photon migration system for integration into commercial hybrid small animal imaging scanners for fluorescence tomography. Phys Med Biol 2012; 57:8135-52. [PMID: 23171509 DOI: 10.1088/0031-9155/57/24/8135] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The work presented herein describes the system design and performance evaluation of a miniaturized near-infrared fluorescence (NIRF) frequency-domain photon migration (FDPM) system with non-contact excitation and homodyne detection capability for small animal fluorescence tomography. The FDPM system was developed specifically for incorporation into a Siemens micro positron emission tomography/computed tomography (microPET/CT) commercial scanner for hybrid small animal imaging, but could be adapted to other systems. Operating at 100 MHz, the system noise was minimized and the associated amplitude and phase errors were characterized to be ±0.7% and ±0.3°, respectively. To demonstrate the tomographic ability, a commercial mouse-shaped phantom with 50 µM IRDye800CW and ⁶⁸Ga containing inclusion was used to associate PET and NIRF tomography. Three-dimensional mesh generation and anatomical referencing was accomplished through CT. A third-order simplified spherical harmonics approximation (SP₃) algorithm, for efficient prediction of light propagation in small animals, was tailored to incorporate the FDPM approach. Finally, the PET-NIRF target co-localization accuracy was analyzed in vivo with a dual-labeled imaging agent targeting orthotopic growth of human prostate cancer. The obtained results validate the integration of time-dependent fluorescence tomography system within a commercial microPET/CT scanner for multimodality small animal imaging.
Collapse
Affiliation(s)
- Chinmay D Darne
- Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, University of Texas Health Science Center at Houston, 1825 Pressler Street, Houston, TX 77030, USA
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Ale A, Ermolayev V, Herzog E, Cohrs C, de Angelis MH, Ntziachristos V. FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography. Nat Methods 2012; 9:615-20. [PMID: 22561987 DOI: 10.1038/nmeth.2014] [Citation(s) in RCA: 178] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2011] [Accepted: 04/02/2012] [Indexed: 11/09/2022]
Abstract
The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.
Collapse
Affiliation(s)
- Angelique Ale
- Technische Universität München and Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Neuherberg, Germany
| | | | | | | | | | | |
Collapse
|
14
|
Solomon M, White BR, Nothdruft RE, Akers W, Sudlow G, Eggebrecht AT, Achilefu S, Culver JP. Video-rate fluorescence diffuse optical tomography for in vivo sentinel lymph node imaging. BIOMEDICAL OPTICS EXPRESS 2011; 2:3267-3277. [PMID: 22162817 PMCID: PMC3233246 DOI: 10.1364/boe.2.003267] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2011] [Revised: 09/15/2011] [Accepted: 09/18/2011] [Indexed: 05/28/2023]
Abstract
We have developed a fiber-based, video-rate fluorescence diffuse optical tomography (DOT) system for noninvasive in vivo sentinel lymph node (SLN) mapping. Concurrent acquisition of fluorescence and reference signals allowed the efficient generation of ratio-metric data for 3D image reconstruction. Accurate depth localization and high sensitivity to fluorescent targets were established in to depths of >10 mm. In vivo accumulation of indocyanine green (ICG) dye was imaged in the region of the SLN following intradermal injection into the forepaw of rats. These results suggest that video-rate fluorescence DOT has significant potential as a clinical tool for noninvasive mapping of SLN.
Collapse
|
15
|
Fu J, Yang X, Wang K, Luo Q, Gong H. A generic, geometric cocalibration method for a combined system of fluorescence molecular tomography and microcomputed tomography with arbitrarily shaped objects. Med Phys 2011; 38:6561-70. [DOI: 10.1118/1.3658727] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
16
|
Baritaux JC, Hassler K, Bucher M, Sanyal S, Unser M. Sparsity-driven reconstruction for FDOT with anatomical priors. IEEE TRANSACTIONS ON MEDICAL IMAGING 2011; 30:1143-53. [PMID: 21507771 DOI: 10.1109/tmi.2011.2136438] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In this paper we propose a method based on (2, 1)-mixed-norm penalization for incorporating a structural prior in FDOT image reconstruction. The effect of (2, 1)-mixed-norm penalization is twofold: first, a sparsifying effect which isolates few anatomical regions where the fluorescent probe has accumulated, and second, a regularization effect inside the selected anatomical regions. After formulating the reconstruction in a variational framework, we analyze the resulting optimization problem and derive a practical numerical method tailored to (2, 1)-mixed-norm regularization. The proposed method includes as particular cases other sparsity promoting regularization methods such as l(1)-norm penalization and total variation penalization. Results on synthetic and experimental data are presented.
Collapse
|
17
|
Fluorescence molecular tomography: principles and potential for pharmaceutical research. Pharmaceutics 2011; 3:229-74. [PMID: 24310495 PMCID: PMC3864234 DOI: 10.3390/pharmaceutics3020229] [Citation(s) in RCA: 100] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2011] [Revised: 04/07/2011] [Accepted: 04/15/2011] [Indexed: 11/17/2022] Open
Abstract
Fluorescence microscopic imaging is widely used in biomedical research to study molecular and cellular processes in cell culture or tissue samples. This is motivated by the high inherent sensitivity of fluorescence techniques, the spatial resolution that compares favorably with cellular dimensions, the stability of the fluorescent labels used and the sophisticated labeling strategies that have been developed for selectively labeling target molecules. More recently, two and three-dimensional optical imaging methods have also been applied to monitor biological processes in intact biological organisms such as animals or even humans. These whole body optical imaging approaches have to cope with the fact that biological tissue is a highly scattering and absorbing medium. As a consequence, light propagation in tissue is well described by a diffusion approximation and accurate reconstruction of spatial information is demanding. While in vivo optical imaging is a highly sensitive method, the signal is strongly surface weighted, i.e., the signal detected from the same light source will become weaker the deeper it is embedded in tissue, and strongly depends on the optical properties of the surrounding tissue. Derivation of quantitative information, therefore, requires tomographic techniques such as fluorescence molecular tomography (FMT), which maps the three-dimensional distribution of a fluorescent probe or protein concentration. The combination of FMT with a structural imaging method such as X-ray computed tomography (CT) or Magnetic Resonance Imaging (MRI) will allow mapping molecular information on a high definition anatomical reference and enable the use of prior information on tissue's optical properties to enhance both resolution and sensitivity. Today many of the fluorescent assays originally developed for studies in cellular systems have been successfully translated for experimental studies in animals. The opportunity of monitoring molecular processes non-invasively in the intact organism is highly attractive from a diagnostic point of view but even more so for the drug developer, who can use the techniques for proof-of-mechanism and proof-of-efficacy studies. This review shall elucidate the current status and potential of fluorescence tomography including recent advances in multimodality imaging approaches for preclinical and clinical drug development.
Collapse
|
18
|
Sauter AW, Wehrl HF, Kolb A, Judenhofer MS, Pichler BJ. Combined PET/MRI: one step further in multimodality imaging. Trends Mol Med 2010; 16:508-15. [PMID: 20851684 DOI: 10.1016/j.molmed.2010.08.003] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2010] [Revised: 08/17/2010] [Accepted: 08/18/2010] [Indexed: 12/11/2022]
Abstract
Given the need for sophisticated in vivo detection techniques to better characterize the cellular and subcellular processes in animals and humans, molecular imaging has become an important discipline. Techniques in molecular imaging have developed from stand alone modalities to multimodality methods. Among these, the combination of positron emission tomography (PET) and computed tomography (CT) is a successful imaging method and has become an important tool in clinical practice. Technological approaches that combine magnetic resonance imaging (MRI) with diffuse optical tomography (DOT), fluorescence tomography (FT) and PET have now been introduced. PET/MRI and the resulting combination of molecular, morphological and functional information will pave the way for a better understanding of physiological and disease mechanisms in preclinical and clinical settings.
Collapse
Affiliation(s)
- Alexander W Sauter
- University of Tuebingen, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Roentgenweg 13, 72076 Tuebingen, Germany
| | | | | | | | | |
Collapse
|
19
|
Lin Y, Barber WC, Iwanczyk JS, Roeck WW, Nalcioglu O, Gulsen G. Quantitative fluorescence tomography using a trimodality system: in vivo validation. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:040503. [PMID: 20799770 PMCID: PMC2937044 DOI: 10.1117/1.3467495] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2010] [Revised: 06/23/2010] [Accepted: 06/25/2010] [Indexed: 05/25/2023]
Abstract
A fully integrated trimodality fluorescence, diffuse optical, and x-ray computed tomography (FT/DOT/XCT) system for small animal imaging is reported in this work. The main purpose of this system is to obtain quantitatively accurate fluorescence concentration images using a multimodality approach. XCT offers anatomical information, while DOT provides the necessary background optical property map to improve FT image accuracy. The quantitative accuracy of this trimodality system is demonstrated in vivo. In particular, we show that a 2-mm-diam fluorescence inclusion located 8 mm deep in a nude mouse can only be localized when functional a priori information from DOT is available. However, the error in the recovered fluorophore concentration is nearly 87%. On the other hand, the fluorophore concentration can be accurately recovered within 2% error when both DOT functional and XCT structural a priori information are utilized together to guide and constrain the FT reconstruction algorithm.
Collapse
|
20
|
Yang X, Gong H, Quan G, Deng Y, Luo Q. Combined system of fluorescence diffuse optical tomography and microcomputed tomography for small animal imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:054304. [PMID: 20515159 DOI: 10.1063/1.3422252] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We developed a dual-modality system that combines fluorescence diffuse optical tomography (fDOT) and flat panel detector-based microcomputed tomography (micro-CT) to simultaneously reveal molecular and structural information in small animals. In fDOT, a 748 nm diode laser was used as an excitation source, while a cooled charge coupled device camera was adopted to collect transmission fluorescence. In micro-CT, a flat panel detector based on amorphous silicon, with active area of 13 x 13 cm(2), and a microfocus x-ray tube were used. The fDOT system was mounted orthogonally to the micro-CT and the projection images were acquired without rotation of the sample, which is different from the method used for micro-CT alone. Both the finite element method and the algebraic reconstruction technique were used to reconstruct images from the fDOT. Phantom data showed that the resolution of the fDOT system was about 3 mm at an imaging depth of 7 mm. Quantitative error was no more than 5% and imaging sensitivity for 1,1(')-dioctadecyl-3,3,3('),3(')-etramethylindotricarbocyanine iodide bis-oleate (DiR-BOA) was estimated to be higher than 100 nM at a depth of 7 mm. Calculations of the phantom's center of mass showed that the location accuracy of fDOT was about 0.7 mm. We applied a Feldkamp algorithm to reconstruct the micro-CT image. By measuring the presampled modulation transfer function with a 30 microm tungsten thread, we estimated that the micro-CT has a resolution of 5 mm(-1) when the field of view was 6.5 cm. Our results indicate the uniformity of the transaxial micro-CT image and the contrast-to-noise ratio was measured as 1.95 for a radiation dose of 1 cGy. A non-image-based method was employed for merging images from the two imaging modalities. A nude mouse with DiR-BOA, imaged ex vivo, was used to validate the feasibility of the dual-modality system.
Collapse
Affiliation(s)
- Xiaoquan Yang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | | | | | | | | |
Collapse
|