1
|
Panneerselvam NK, Sudhir BJ, Kannath SK, Patnaik BSV. Influence of framing coil orientation and its shape on the hemodynamics of a basilar aneurysm model. Med Biol Eng Comput 2024; 62:3411-3432. [PMID: 38856881 DOI: 10.1007/s11517-024-03146-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Accepted: 05/28/2024] [Indexed: 06/11/2024]
Abstract
Aneurysms are bulges of an artery, which require clinical management solutions. Due to the inherent advantages, endovascular coil filling is emerging as the treatment of choice for intracranial aneurysms (IAs). However, after successful treatment of coil embolization, there is a serious risk of recurrence. It is well known that optimal packing density will enhance treatment outcomes. The main objective of endovascular coil embolization is to achieve flow stasis by enabling significant reduction in intra-aneurysmal flow and facilitate thrombus formation. The present study numerically investigates the effect of framing coil orientation on intra-aneurysmal hemodynamics. For the purpose of analysis, actual shape of the embolic coil is used, instead of simplified ideal coil shape. Typically used details of the framing coil are resolved for the analysis. However, region above the framing coil is assumed to be filled with a porous medium. Present simulations have shown that orientation of the framing coil loop (FCL) greatly influences the intra-aneurysmal hemodynamics. The FCLs which were placed parallel to the outlets of basilar tip aneurysm (Coil A) were found to reduce intra-aneurysmal flow velocity that facilitates thrombus formation. Involving the coil for the region is modeled using a porous medium model with a packing density of 20 % . The simulations indicate that the framing coil loop (FCL) has a significant influence on the overall outcome.
Collapse
Affiliation(s)
- Nisanth Kumar Panneerselvam
- Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, 600036, Tamilnadu, India
| | - B J Sudhir
- Department of Neurosurgery, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, 695011, Kerala, India.
| | - Santhosh K Kannath
- Department of Imaging Sciences and Interventional Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, 695011, Kerala, India
| | - B S V Patnaik
- Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, 600036, Tamilnadu, India.
| |
Collapse
|
2
|
Hanel RA, Cortez GM, Jankowitz BT, Sauvageau E, Aghaebrahim A, Lin E, Jadhav AP, Gross B, Khaldi A, Gupta R, Frei D, Loy D, Price LL, Hetts SW, Zaidat OO. Anterior circulation location-specific results for stent-assisted coiling - carotid versus distal aneurysms: 1-year outcomes from the Neuroform Atlas Stent Pivotal Trial. J Neurointerv Surg 2024; 16:1125-1130. [PMID: 37940387 PMCID: PMC11503183 DOI: 10.1136/jnis-2023-020591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 09/19/2023] [Indexed: 11/10/2023]
Abstract
BACKGROUND The Neuroform Atlas Stent System is an established treatment modality for unruptured anterior and posterior circulation intracranial aneurysms. Location-specific results are needed to guide treatment decision-making. However, it is unclear whether there are differences in safety and efficacy outcomes between carotid and more distal anterior circulation aneurysms. METHODS The ATLAS IDE trial was a prospective, multicenter, single-arm, open-label interventional study that evaluated the safety and efficacy of the Neuroform Atlas Stent System. We compared differences in efficacy and safety outcomes of proximal internal carotid artery (ICA) versus distal and bifurcation anterior circulation aneurysms. RESULTS Of 182 cases, there were 70 aneurysms in the ICA and 112 in the distal anterior circulation (including ICA terminus/bifurcation). There were no significant differences in the primary efficacy endpoint (85.5% vs 83.9%, p=0.78) and complete aneurysm occlusion rates (88.7% vs 87.9%, p=0.78) between proximal ICA aneurysms and distal aneurysms, respectively. Complications were more often encountered in distal and bifurcation aneurysms, but the overall rate of major safety events was low and comparable between the two groups (1.4% vs 6.3%, p=0.14). Recanalization and retreatment rates were also similar between the groups. CONCLUSION The results of this study suggest that the Neuroform Atlas Stent System is a safe and efficacious treatment modality for unruptured anterior circulation intracranial aneurysms, regardless of aneurysm location. TRIAL REGISTRATION NUMBER NCT02340585.
Collapse
Affiliation(s)
- Ricardo A Hanel
- Lyerly Neurosurgery, Baptist Medical Center Jacksonville, Jacksonville, Florida, USA
| | - Gustavo M Cortez
- Lyerly Neurosurgery, Baptist Medical Center Jacksonville, Jacksonville, Florida, USA
| | - Brian T Jankowitz
- Neurosurgery, Cooper Hospital University Medical Center, Camden, New Jersey, USA
| | - Eric Sauvageau
- Lyerly Neurosurgery, Baptist Medical Center Jacksonville, Jacksonville, Florida, USA
| | - Amin Aghaebrahim
- Lyerly Neurosurgery, Baptist Medical Center Jacksonville, Jacksonville, Florida, USA
| | - Eugene Lin
- Neuroscience, Mercy Health Saint Vincent Medical Center, Toledo, Ohio, USA
| | - Ashutosh P Jadhav
- Neurology, University of Pittsburgh Medical Center Health System, Pittsburgh, Pennsylvania, USA
- Neurology, Barrow Neurological Institute, Phoenix, Arizona, USA
| | - Bradley Gross
- Neurosurgery, University of Pittsburgh Medical Center Health System, Pittsburgh, Pennsylvania, USA
| | - Ahmad Khaldi
- Neurosurgery, WellStar Health System, Marietta, Georgia, USA
| | - Rishi Gupta
- Neurosurgery, WellStar Health System, Marietta, Georgia, USA
| | - Donald Frei
- Radiology Imaging Associates, Swedish Medical Center, Englewood, Colorado, USA
| | - David Loy
- Radiology Imaging Associates, Swedish Medical Center, Englewood, Colorado, USA
| | | | - Steven W Hetts
- Radiology, University of California San Francisco, San Francisco, California, USA
| | - Osama O Zaidat
- Neuroscience, Mercy Health Saint Vincent Medical Center, Toledo, Ohio, USA
| |
Collapse
|
3
|
Hu X, Deng P, Ma M, Tang X, Qian J, Wu G, Gong Y, Gao L, Zou R, Leng X, Xiang J, Wu J, Ding Z. How does the recurrence-related morphology characteristics of the Pcom aneurysms correlated with hemodynamics? Front Neurol 2023; 14:1236757. [PMID: 37869148 PMCID: PMC10585265 DOI: 10.3389/fneur.2023.1236757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 09/21/2023] [Indexed: 10/24/2023] Open
Abstract
Introduction Posterior communicating artery (Pcom) aneurysm has unique morphological characteristics and a high recurrence risk after coil embolization. This study aimed to evaluate the relationship between the recurrence-related morphology characteristics and hemodynamics. Method A total of 20 patients with 22 Pcom aneurysms from 2019 to 2022 were retrospectively enrolled. The recurrence-related morphology parameters were measured. The hemodynamic parameters were simulated based on finite element analysis and computational fluid dynamics. The hemodynamic differences before and after treatment caused by different morphological features and the correlation between these parameters were analyzed. Result Significant greater postoperative inflow rate at the neck (Qinflow), relative Qinflow, inflow concentration index (ICI), and residual flow volume (RFV) were reported in the aneurysms with wide neck (>4 mm). Significant greater postoperative RFV were reported in the aneurysms with large size (>7 mm). Significant greater postoperative Qinflow, relative Qinflow, and ICI were reported in the aneurysms located on the larteral side of the curve. The bending angle of the internal carotid artery at the initiation of Pcom (αICA@PCOM) and neck diameter had moderate positive correlations with Qinflow, relative Qinflow, ICI, and RFV. Conclusion The morphological factors, including aneurysm size, neck diameter, and αICA@PCOM, are correlated with the recurrence-inducing hemodynamic characteristics even after fully packing. This provides a theoretical basis for evaluating the risk of aneurysm recurrence and a reference for selecting a surgical plan.
Collapse
Affiliation(s)
- Xiaolong Hu
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Peng Deng
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Mian Ma
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Xiaoyu Tang
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Jinghong Qian
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Gang Wu
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Yuhui Gong
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Liping Gao
- ArteryFlow Technology Co., Ltd., Hangzhou, China
| | - Rong Zou
- ArteryFlow Technology Co., Ltd., Hangzhou, China
| | | | | | - Jiandong Wu
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| | - Zhiliang Ding
- Department of Neurosurgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, Jiangsu, China
| |
Collapse
|
4
|
Wan H, Lu G, Ge L, Huang L, Jiang Y, Leng X, Xiang J, Zhang X. Hemodynamic Effects of Stent-Induced Straightening of Parent Artery vs. Stent Struts for Intracranial Bifurcation Aneurysms. Front Neurol 2022; 12:802413. [PMID: 35211076 PMCID: PMC8862758 DOI: 10.3389/fneur.2021.802413] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 12/20/2021] [Indexed: 11/13/2022] Open
Abstract
Objective This study aims to compare the hemodynamic impact of stent-mesh and stent-induced straightening of the parent artery in intracranial bifurcation aneurysms using finite element method simulation. Material and Methods Three intracranial bifurcation aneurysms treated with different stent-assisted coil embolization were evaluated. Simulation using the finite element method was conducted for Solitaire, LVIS and Neuroform stents. Four models of each stent were established, including a pre-treatment baseline, stenting without parent artery straightening (presented as stent-mesh effect), no-stent with parent artery reconstruction (to reveal the straightening impact), and stenting with straightening (categorized as Models I–IV respectively). Hemodynamic characteristics of the four models for each stent were compared. Results In the Neuroform stent, compared with the pre-treatment model (100%), the mean WSS decreased to 82.3, 71.4, and 57.0% in Models II-IV, velocity to 88.3, 74.4, and 62.8%, and high flow volume (HFV, >0.3 m/s) to 77.7, 44.0, and 19.1%. For the LVIS stent, the mean WSS changed to 105.0, 40.2, and 39.8% in Models II to IV; velocity to 91.2, 58.1, and 52.5%, and HFV to 92.0, 56.1, and 43.9%. For the Solitaire stent, compared with the pre-treatment model (100%), the mean WSS of Models II-IV changed altered by 105.7, 42.6, and 39.4%, sac-averaged velocity changed to 111.3, 46.6, and 42.8%, and HFV 115.6, 15.1, and 13.6%. Conclusion The hemodynamic effect of straightening the parent artery of intracranial bifurcation aneurysms by stenting was noticeably improved over stent mesh diversion in all three stents tested. Therefore stent-induced remodeling of the parent artery appears to be the best method of decreasing recurrence in intracranial bifurcation aneurysms.
Collapse
Affiliation(s)
- Hailin Wan
- Huashan Hospital, Fudan University, Shanghai, China
| | - Gang Lu
- Huashan Hospital, Fudan University, Shanghai, China
| | - Liang Ge
- Huashan Hospital, Fudan University, Shanghai, China
| | - Lei Huang
- Huashan Hospital, Fudan University, Shanghai, China
| | - Yeqing Jiang
- Huashan Hospital, Fudan University, Shanghai, China
| | | | | | | |
Collapse
|
5
|
Low-profile LEO baby stents using dual stenting technique in treating complex intracranial aneurysms located in small artery: Initial and mid-term outcome. J Clin Neurosci 2022; 98:109-114. [PMID: 35152146 DOI: 10.1016/j.jocn.2022.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 02/03/2022] [Accepted: 02/04/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND Endovascular treatment of complex intracranial aneurysms (IAs) was challenging. Our retrospective study aimed to assess the efficacy and safety of LEO Baby stents using the dual stenting technique for complex IAs. METHODS Clinical and angiographic data of 15 IAs located in small arteries treated by LEO Baby stents in our neurosurgical center were retrospectively collected and analyzed between April 2019 to January 2021. RESULTS 15 patients received dual stent-assisted coiling procedures and the stent configurations include 7 cases of T- configuration, 5 cases of parallel- configuration, 2 cases of Y- configuration, and 1case of X- configuration. 11 patients received dual stents deployment with only LEO Baby stents and 4 patients received LEO Baby stent combined with LVIS stent. Immediate postprocedural results showed Raymond I in 4 patients (26.7%), Raymond II in 5 patients (33.3%), and Raymond III in 6 patients (40.0%). One patient (6.7%) was confirmed with an ischemic complication during the procedure. All 15 patients (100%) received clinical follow-up ranging between 6 and 28 months. An mRS score of 0-2 was reached in all patients. 13 patients (86.7%) received angiographic clinical follow-up ranging between 6 and 20 months. The results revealed that Raymond I was achieved in 10 patients (76.9%) and Raymond II was achieved in 3 patients (23.1%). One patient (7.7%) in 6 months after the procedure was confirmed with asymptomatic in-stent stenosis. CONCLUSION This preliminary study suggests that dual stents deployment of LEO Baby stents was a feasible strategy for the treatment of complex IAs located in the small arteries.
Collapse
|