1
|
Ballestero-Arnau M, Rodríguez-Herreros B, Nuño-Bermúdez N, Cunillera T. Sporadic fasting reduces attentional control without altering overall executive function in a binary classification task. Physiol Behav 2023; 260:114065. [PMID: 36549561 DOI: 10.1016/j.physbeh.2022.114065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 12/23/2022]
Abstract
Diets with intermittent fasting are an efficient method for producing clinically significant weight loss and preventing the development of obesity. However, individuals following intermittent fasting must face the difficulty of avoiding eating when experiencing the feeling of hunger. In this study, we investigated which aspects of executive function were affected following a prolonged period of food deprivation in participants that have never previously undergone intermittent fasting. Twenty-six participants with normal weight performed two binary classification tasks (Stop Signal (SST) and Go/NoGo) after either a 12 h fasting or a nonfasting period in separate sessions. We measured their performance in several underlying decision-making processes, such as response inhibition and attentional control. In line with previous studies, our results revealed that decision-making processes to resolve the classification task were unaffected by fasting. Response inhibition, as indexed by the stop signal reaction time in the SST, remained as well unaltered after food deprivation. Rather, we observed a higher error rate in NoGo trials following a fasting period, which was associated with disrupted attentional control. Overall, these results indicate that when a hunger feeling reaches consciousness, it induces deficits over certain aspects of attentional control. Our findings hint at the importance of structured behavioral change strategies to cope with fasting-induced difficulties in attentional control, to help achieve weight management goals through successful self-monitoring of food intake.
Collapse
Affiliation(s)
- M Ballestero-Arnau
- Department of Cognition, Development and Educational Psychology. Faculty of Psychology, University of Barcelona; Pg. Vall d'Hebron, 171; 08035, Barcelona, Spain; Institute of Neurosciences (UBNeuro), University of Barcelona, Barcelona, Spain
| | - B Rodríguez-Herreros
- Service des Troubles du Spectre de l'Autisme et apparentés, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland
| | - N Nuño-Bermúdez
- Department of Cognition, Development and Educational Psychology. Faculty of Psychology, University of Barcelona; Pg. Vall d'Hebron, 171; 08035, Barcelona, Spain
| | - T Cunillera
- Department of Cognition, Development and Educational Psychology. Faculty of Psychology, University of Barcelona; Pg. Vall d'Hebron, 171; 08035, Barcelona, Spain; Institute of Neurosciences (UBNeuro), University of Barcelona, Barcelona, Spain.
| |
Collapse
|
2
|
Battelino T, Bosnyak Z, Danne T, Mukherjee B, Edelman S, Pilorget V, Choudhary P, Renard E, Bergenstal R. InRange: Comparison of the Second-Generation Basal Insulin Analogues Glargine 300 U/mL and Degludec 100 U/mL in Persons with Type 1 Diabetes Using Continuous Glucose Monitoring-Study Design. Diabetes Ther 2020; 11:1017-1027. [PMID: 32100192 PMCID: PMC7136362 DOI: 10.1007/s13300-020-00781-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Indexed: 01/18/2023] Open
Abstract
INTRODUCTION Suboptimal glycaemic control among people with type 1 diabetes (T1D) is known to lead to long-term micro- and macrovascular complications and, unfortunately, it is still prevalent even in the most affluent societies. Although glycated haemoglobin monitoring is considered to be the gold standard for assessing glycaemic control, such monitoring is unable to reliably measure acute glycaemic excursions. Continuous glucose monitoring (CGM) has been shown to improve glucose control and reduce the incidence of hypoglycaemia, and also allow a more complete assessment of overall glycaemic control and hyper- and hypoglycaemic excursions. The use of CGM has led to time-in-range, which is the time that a patient is within the glycaemic range of 70 to 180 mg/dL, to be adopted as a treatment target. To date, only limited data comparing the second-generation insulins glargine 300 U/mL (Gla-300) and degludec 100 U/mL (IDeg-100) in people with T1D are available, and there is no CGM literature on comparisons of the use of CGM results to assess primary, secondary and tertiary endpoints. The aim of the InRange study was to address this unmet need. METHODS InRange is a multicentre, randomised, active-controlled, parallel-group, 12-week, open-label, phase 4, comparative study. Adults with T1D will be randomised to receive once-daily Gla-300 or IDeg-100 by subcutaneous injection in the morning. Following an 8-week titration period, CGM data will be collected over 20 consecutive days. PLANNED OUTCOMES The primary objective is to demonstrate that Gla-300 is noninferior to IDeg-100 in terms of glycaemic control [time-in-range ≥ 70 to ≤ 180 mg/dL (≥ 3.9 to ≤ 10 mmol/L)] and variability, as assessed using CGM, in adults with T1D. The results are expected to help confirm the utility of CGM in clinical practice in this population and provide insight into its application as an outcome measure in clinical practice. TRIAL REGISTRATION NCT04075513.
Collapse
Affiliation(s)
- Tadej Battelino
- UMC-University Children's Hospital, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia.
| | | | - Thomas Danne
- Diabetes Centre for Children and Adolescents, Children's and Youth Hospital "Auf Der Bult", Hannover, Germany
| | | | | | | | - Pratik Choudhary
- King's College Hospital NHS Foundation Trust, London, UK
- Department of Diabetes, School of Life Course Sciences, King's College London, London, UK
| | - Eric Renard
- Department of Endocrinology, Diabetes and Nutrition, Montpellier University Hospital, University of Montpellier, Montpellier, France
- Institute of Functional Genomics, University of Montpellier, Montpellier, France
- INSERM Clinical Investigation Centre, Montpellier, France
| | | |
Collapse
|
3
|
Increased risk of hepatitis B virus infection amongst individuals with diabetes mellitus. Biosci Rep 2019; 39:BSR20181715. [PMID: 30858308 PMCID: PMC6438870 DOI: 10.1042/bsr20181715] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 03/06/2019] [Accepted: 03/07/2019] [Indexed: 02/05/2023] Open
Abstract
There have been reports of hepatitis B outbreaks amongst diabetics in long-term care facilities, suggesting that risk of hepatitis B virus (HBV) infection is higher in this population. However, the magnitude of the risk and the incidence of HBV infection amongst the general diabetic population in China remains unknown. Data from a cohort study conducted in Mianyang City, Sichuan Province, China, were retrospectively analyzed in order to address this question. Demographic information was collected using a custom-designed questionnaire, and blood samples were tested for HBV using ELISA. We used multivariate logistic regression to explore the relationship between HBV infection and diabetes, while adjusting for age, sex, region, medical insurance, exposure history, and HBV vaccination. During 2013-2014, a total of 189766 adults were surveyed, of which 7382 were newly infected with HBV, corresponding to an incidence of 3.89%. In this study population, there were 4982 diabetic patients and 182710 non-diabetic individuals. Amongst those with diabetes, 265 (5.32%) were newly infected with HBV. In contrast, 7038 (3.85%) in the non-diabetic population were newly infected with HBV. The relative risk (RR) of HBV infection was 43% higher amongst those diagnosed with diabetes than amongst those not diagnosed (RR 1.43, 95% confidence interval (CI) 1.26-1.63). These results suggest that the risk of HBV infection is higher amongst individuals diagnosed with diabetes mellitus in Mianyang City, Sichuan Province, China. Hepatitis B vaccination and continuous infection control practices may help to reduce HBV infection in diabetic patients, and should be considered for diabetes management.
Collapse
|
4
|
Lin SP, Lin WY, Chang JT, Chu CF. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013. PLoS One 2017; 12:e0180617. [PMID: 28683148 PMCID: PMC5500346 DOI: 10.1371/journal.pone.0180617] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Accepted: 06/18/2017] [Indexed: 11/18/2022] Open
Abstract
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.
Collapse
Affiliation(s)
- Shu-Ping Lin
- Graduate Institute of Biomedical Engineering, National Chung Hsing University, Taichung, Taiwan R.O.C
- Research Center for Sustainable Energy and Nanotechnology, National Chung Hsing University, Taichung, Taiwan R.O.C
| | | | | | | |
Collapse
|
5
|
Chang H, Yeh YJ, Lee R, Shyu JH. A feature study of innovative high-speed lancing device and safety lancet. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2016; 39:895-902. [PMID: 27766600 DOI: 10.1007/s13246-016-0490-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2016] [Accepted: 09/30/2016] [Indexed: 11/28/2022]
Abstract
The study developed two models of an innovative high-speed lancing device and safety lancet, where the specially designed structure causes high-speed motion of the lancet, resulting in only one puncture of the skin. The two experimental models and other lancing devices sold on market were compared in order to: (1) measure the forces of lancets piercing animal skin by a load cell; (2) observe the wound areas caused by lancing devices under a microscope. The experimental results showed that, after using this innovative high-speed lancing device, the maximum force of a lancet piercing skin is only 1/3 of the force of conventional lancing devices, and the duration of the former under the skin is 1/6 of the latter. In addition, the wound area caused by the innovative lancing device is 20 % smaller than those of the conventional lancing devices. Usage of this innovative high-speed safety lancet shows that its maximum skin-piercing force is only 2/3 of conventional safety lancets, its duration under the skin is 1/4 of conventional safety lancets, and the wound area is 12 % smaller. In conclusion, both the innovative high-speed lancing device and safety lancet are proved effective in alleviating pain for diabetics and shortening the recovering time for wounds, thus, providing a more comfortable process for the self-monitoring of blood glucose.
Collapse
Affiliation(s)
- Ho Chang
- Graduate Institute of Manufacturing Technology, National Taipei University of Technology, No.1, Sec. 3, Zhongxiao E. Rd, Taipei, 10608, Taiwan
| | - Yao-Jen Yeh
- Graduate Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan.
| | - Rahnfong Lee
- Graduate Institute of Manufacturing Technology, National Taipei University of Technology, No.1, Sec. 3, Zhongxiao E. Rd, Taipei, 10608, Taiwan
| | - Jenq-Huey Shyu
- Graduate Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan
| |
Collapse
|
6
|
Design and Performance of Innovative High-Speed Lancing Device. J Med Biol Eng 2016. [DOI: 10.1007/s40846-016-0177-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
7
|
Characterization and Clinical Trial of an Innovative High-Speed Lancing Device. APPLIED SCIENCES-BASEL 2016. [DOI: 10.3390/app6040111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
8
|
Reilly ML, Schillie SF, Smith E, Poissant T, Vonderwahl CW, Gerard K, Baumgartner J, Mercedes L, Sweet K, Muleta D, Zaccaro DJ, Klevens RM, Murphy TV. Increased risk of acute hepatitis B among adults with diagnosed diabetes mellitus. J Diabetes Sci Technol 2012; 6:858-66. [PMID: 22920812 PMCID: PMC3440157 DOI: 10.1177/193229681200600417] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
INTRODUCTION The risk of acute hepatitis B among adults with diabetes mellitus is unknown. We investigated the association between diagnosed diabetes and acute hepatitis B. METHODS Confirmed acute hepatitis B cases were reported in 2009-2010 to eight Emerging Infections Program (EIP) sites; diagnosed diabetes status was determined. Behavioral Risk Factor Surveillance System respondents residing in EIP sites comprised the comparison group. Odds ratios (ORs) comparing acute hepatitis B among adults with diagnosed diabetes versus without diagnosed diabetes were determined by multivariate logistic regression, adjusting for age, sex, and race/ethnicity, and stratified by the presence or absence of risk behaviors for hepatitis B virus (HBV) infection. RESULTS During 2009-2010, EIP sites reported 865 eligible acute hepatitis B cases among persons aged ≥23 years; 95 (11.0%) had diagnosed diabetes. Comparison group diabetes prevalence was 9.1%. Among adults without hepatitis B risk behaviors and with reported diabetes status, the OR for acute hepatitis B comparing adults with and without diabetes was 1.9 (95% confidence interval [CI] = 1.4, 2.6); ORs for adults ages 23-59 and ≥60 years were 2.1 (95% CI = 1.6, 2.8) and 1.5 (95% = CI 0.9, 2.5), respectively. CONCLUSIONS Diabetes was independently associated with an increased risk for acute hepatitis B among adults without HBV risk behaviors.
Collapse
Affiliation(s)
- Meredith L. Reilly
- Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Sarah F. Schillie
- Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Emily Smith
- Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia
| | | | | | - Kristin Gerard
- Connecticut Department of Public Health, Hartford, Connecticut
| | - Jennifer Baumgartner
- New York City Department of Health and Mental Hygiene, Long Island City, New York
| | | | | | - Daniel Muleta
- Tennessee Department of Health, Nashville, Tennessee
| | | | - R. Monina Klevens
- Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Trudy V. Murphy
- Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia
| |
Collapse
|
9
|
Viswanathan S, Li P, Choi W, Filipek S, Balasubramaniam TA, Renugopalakrishnan V. Protein-carbon nanotube sensors: single platform integrated micro clinical lab for monitoring blood analytes. Methods Enzymol 2012; 509:165-94. [PMID: 22568906 DOI: 10.1016/b978-0-12-391858-1.00010-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Design of a unique, single-platform, integrated, multichannel sensor based on carbon nanotube (CNT)-protein adducts specific to each one of the major analytes of blood, glucose, cholesterol, triglyceride, and Hb1AC is presented. The concept underlying the sensor, amperometric detection, is applicable to various disease-monitoring strategies. There is an urgent need to enhance the sensitivity of glucometers to <5% level instead of greater than the present 15% standard in these detectors. CNTs enhance the signals derived from the interaction of the enzymes with the different analytes in blood. Fabricated sensors using the new methodology is a point-of-care device that is targeted for home, clinical, and emergency use and can be redesigned for continuous monitoring for critical care patients.