1
|
Howe EE, Bent LR. Pressure-Induced Microvascular Reactivity With Whole Foot Loading Is Unique Across the Human Foot Sole. Microcirculation 2025; 32:e12893. [PMID: 39531225 DOI: 10.1111/micc.12893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 09/06/2024] [Accepted: 10/21/2024] [Indexed: 11/16/2024]
Abstract
BACKGROUND Foot sole plantar pressure generates transient but habitual cutaneous ischemia, which is even more exacerbated in atypical gait patterns. Thus, adequate post-occlusive reactive hyperaemia (PORH) is necessary to maintain skin health. Plantar pressure regional variance during daily tasks potentially generates region-specific PORH, crucial for ischemic defence. AIMS The current work investigated regional PORH across the human foot sole resulting from stance-like loading. MATERIALS & METHODS A loading device equipped with an in-line laser speckle contrast imager measured blood flux before, during, and after whole-foot loading for 2 and 10 min durations at 15% and 50% body weight. Flux was compared between six regions: the heel, lateral arch, medial arch, and fifth, third, and first metatarsals (MT). RESULTS Baseline flux was significantly greater in the 1MT and 3MT than all other regions. Loading occluded the heel, 5MT and 3MT more than all other regions. Regional PORH peak, time to peak, area under the curve, and recovery rate were ranked between regions. DISCUSSION The 3MT, followed by 5MT, overall had the strongest PORH response, suggesting a heightened protection against ischemia compared to other regions. CONCLUSION This work highlights regional variations within a healthy foot, providing a framework for future ulcer risk assessments and interventions to preserve foot health.
Collapse
Affiliation(s)
- Erika E Howe
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, Ontario, Canada
| | - Leah R Bent
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, Ontario, Canada
| |
Collapse
|
2
|
Bahrami F, Psikuta A, Rossi RM, Dommann A, Defraeye T. Exploring the thermally-controlled fentanyl transdermal therapy to provide constant drug delivery by physics-based digital twins. Eur J Pharm Sci 2024; 200:106848. [PMID: 38986719 DOI: 10.1016/j.ejps.2024.106848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 06/20/2024] [Accepted: 07/07/2024] [Indexed: 07/12/2024]
Abstract
Transdermal drug delivery is suitable for low-molecular-weight drugs with specific lipophilicity, like fentanyl, which is widely used for cancer-induced pain management. However, fentanyl's transdermal therapy displays high intra-individual variability. Factors like skin characteristics at application sites and ambient temperature contribute to this variation. In this study, we developed a physics-based digital twin of the human body to cope with this variability and propose better adapted setups. This twin includes an in-silico skin model for drug penetration, a pharmacokinetic model, and a pharmacodynamic model. Based on the results of our simulations, applying the patch on the flank (side abdominal area) showed a 15.3 % higher maximum fentanyl concentration in the plasma than on the chest. Additionally, the time to reach this maximum concentration when delivered through the flank was 19.8 h, which was 10.3 h earlier than via the upper arm. Finally, this variation led to an 18 % lower minimum pain intensity for delivery via the flank than the chest. Moreover, the impact of seasonal changes on ambient temperature and skin temperature by considering the activity level was investigated. Based on our result, the fentanyl uptake flux by capillaries increased by up to 11.8 % from an inactive state in winter to an active state in summer. We also evaluated the effect of controlling fentanyl delivery by adjusting the temperature of the patch to alleviate the pain to reach a mild pain intensity (rated three on the VAS scale). By implementing this strategy, the average pain intensity decreased by 1.1 points, and the standard deviation for fentanyl concentration in plasma and average pain intensity reduced by 37.5 % and 33.3 %, respectively. Therefore, our digital twin demonstrated the efficacy of controlled drug release through temperature regulation, ensuring the therapy toward the intended target outcome and reducing therapy outcome variability. This holds promise as a potentially useful tool for physicians.
Collapse
Affiliation(s)
- Flora Bahrami
- Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, Empa, Lerchenfeldstrasse 5, CH-9014St. Gallen, Switzerland; ARTORG Center for Biomedical Engineering Research, University of Bern, Mittelstrasse 43, Bern CH-3012, Switzerland
| | - Agnes Psikuta
- Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, Empa, Lerchenfeldstrasse 5, CH-9014St. Gallen, Switzerland
| | - René Michel Rossi
- Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, Empa, Lerchenfeldstrasse 5, CH-9014St. Gallen, Switzerland
| | - Alex Dommann
- ARTORG Center for Biomedical Engineering Research, University of Bern, Mittelstrasse 43, Bern CH-3012, Switzerland
| | - Thijs Defraeye
- Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, Empa, Lerchenfeldstrasse 5, CH-9014St. Gallen, Switzerland.
| |
Collapse
|
3
|
Peng C, Huang G, Chen X, Xie Z, Ali S, Chen X, Nie H, Yang Z, Zhu L, Chen X, Yan S. Identification of near-infrared characteristic bands of small bowel necrosis based on cellwise detection algorithm. JOURNAL OF BIOPHOTONICS 2024; 17:e202300438. [PMID: 38468556 DOI: 10.1002/jbio.202300438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 01/10/2024] [Accepted: 01/30/2024] [Indexed: 03/13/2024]
Abstract
The near-infrared spectroscopy is often used to distinguish small bowel necrosis due to necrotizing enterocolitis (NEC). The characteristic bands of small bowel necrosis, as an important basis for evaluating the confidence of the differentiation results, are challenging to identify quickly. In this study, we proposed to identify characteristic bands of lesion samples based on hyperspectral imaging (HSI) and cellwise outlier detection. Rabbits were used as an animal model to simulate the clinical symptoms of NEC. The rabbits were detected at intervals of 10, 30, 60, and 90 min. The characteristic bands were identified within the same rabbit, between different rabbits and at different times. The result showed the bands near 763 nm, corresponding to the absorption peak of deoxyhemoglobin, were the characteristic bands separating samples with NEC. The identification result was plausible because hypoxia was the main cause of NEC. The method was easy to perform.
Collapse
Affiliation(s)
- Chenxi Peng
- College of Life and Environmental Sciences, Wenzhou University, Wenzhou, China
| | - Guangzao Huang
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Xiaojing Chen
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Zhonghao Xie
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Shujat Ali
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Xi Chen
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Huagui Nie
- College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, China
| | - Zhi Yang
- College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, China
| | - Libin Zhu
- Pediatric General Surgery, The Second Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Xiaoqing Chen
- Pediatric General Surgery, The Second Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Shubin Yan
- School of Electrical Engineering, Zhejiang University of Water Resources and Electric Power, Hangzhou, China
| |
Collapse
|
4
|
Howe EE, Apollinaro M, Bent LR. Mechanoreceptor sensory feedback is impaired by pressure induced cutaneous ischemia on the human foot sole and can predict cutaneous microvascular reactivity. Front Neurosci 2024; 18:1329832. [PMID: 38629048 PMCID: PMC11019310 DOI: 10.3389/fnins.2024.1329832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 03/06/2024] [Indexed: 04/19/2024] Open
Abstract
Introduction The foot sole endures high magnitudes of pressure for sustained periods which results in transient but habitual cutaneous ischemia. Upon unloading, microvascular reactivity in cutaneous capillaries generates an influx of blood flow (PORH: post-occlusive reactive hyperemia). Whether pressure induced cutaneous ischemia from loading the foot sole impacts mechanoreceptor sensitivity remains unknown. Methods Pressure induced ischemia was attained using a custom-built-loading device that applied load to the whole right foot sole at 2 magnitudes (15 or 50% body weight), for 2 durations (2 or 10 minutes) in thirteen seated participants. Mechanoreceptor sensitivity was assessed using Semmes-Weinstein monofilaments over the third metatarsal (3MT), medial arch (MA), and heel. Perceptual thresholds (PT) were determined for each site prior to loading and then applied repeatedly to a metronome to establish the time course to return to PT upon unload, defined as PT recovery time. Microvascular flux was recorded from an in-line laser speckle contrast imager (FLPI-2, Moor Instruments Inc.) to establish PORH peak and recovery rates at each site. Results PT recovery and PORH recovery rate were most influenced at the heel and by load duration rather than load magnitude. PT recovery time at the heel was significantly longer with 10 minutes of loading, regardless of magnitude. Heel PORH recovery rate was significantly slower with 10minutes of loading. The 3MT PT recovery time was only longer after 10 minutes of loading at 50% body weight. Microvascular reactivity or sensitivity was not influenced with loading at the MA. A simple linear regression found that PORH recovery rate could predict PT recovery time at the heel (R2=0.184, p<0.001). Conclusion In populations with degraded sensory feedback, such as diabetic neuropathy, the risk for ulcer development is heightened. Our work demonstrated that prolonged loading in healthy individuals can impair skin sensitivity, which highlights the risks of prolonged loading and is likely exacerbated in diabetes. Understanding the direct association between sensory function and microvascular reactivity in age and diabetes related nerve damage, could help detect early progressions of neuropathy and mitigate ulcer development.
Collapse
Affiliation(s)
- Erika E. Howe
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON, Canada
| | | | | |
Collapse
|
5
|
Sharif F, Ahmad A, Shabbir A. Does the ultrasound imaging predict lower limb tendinopathy in athletes: a systematic review. BMC Med Imaging 2023; 23:217. [PMID: 38129787 PMCID: PMC10740248 DOI: 10.1186/s12880-023-01181-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 12/11/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND To conduct a systematic review looking into the possibility of US imaging to anticipate and identify future patellar or Achilles tendinopathy symptoms. METHODS The studies that were taken into consideration for this review were prospective studies that employed baseline US imaging of the patellar OR Achilles tendons in asymptomatic patients and follow-up measures of pain and/or function. Two impartial reviewers evaluated the study's quality using the Critical Appraisal Skills Programme instrument. RESULTS Participants in the included studies in this review came from various sports. The systematic review revealed a link between baseline tendon abnormalities in the US and a higher chance of developing both patellar and Achilles tendinopathy as well as their future occurrence. Nine of the included studies examined the patellar tendon alone, eight the patellar and Achilles tendon together, and four the Achilles tendon exclusively. For both tendons, US administration is done in a largely consistent manner. The tendon abnormalities of tendon thickness, hypoechogenicity and vascularity at baseline were associated with an increased risk of both Achilles and patellar tendinopathy. CONCLUSIONS This systematic review shows that abnormal tendon structures seen by US in asymptomatic persons can predict the development of tendinopathy.
Collapse
Affiliation(s)
- Faiza Sharif
- University Institute of Physical Therapy, The University of Lahore, Lahore, Pakistan.
| | - Ashfaq Ahmad
- Faculty of Allied Health Sciences, The University of Lahore, Lahore, Pakistan
| | | |
Collapse
|
6
|
Deng Y, Ohgami N, Kagawa T, Kurniasari F, Chen D, Kato M, Tazaki A, Aoki M, Katsuta H, Tong K, Gu Y, Kato M. Vascular endothelium as a target tissue for short-term exposure to low-frequency noise that increases cutaneous blood flow. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 851:158828. [PMID: 36191705 DOI: 10.1016/j.scitotenv.2022.158828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 08/09/2022] [Accepted: 09/13/2022] [Indexed: 06/16/2023]
Abstract
Harmful health effects of exposure to low-frequency noise (LFN) defined as noise with frequencies at ≤100 Hz on the circulatory system have been a concern. However, there has been no study on the effects of exposure to LFN on the circulatory system with consideration of its frequencies and decibels. In this study, the effects of short-term exposure to broad-band LFNs and their pure-tone components (pure-tone LFNs) on cutaneous blood flow in the extremities including the hands were investigated. In our fieldwork study, we first sampled some kinds of common broad-band LFNs. Our human study then showed that broad-band LFN with a narrower frequency range more strongly increased cutaneous blood flow than did broad-band LFN with a wider frequency range. Pure-tone LFNs of 70-100 Hz at ≤85 dB(Z), but not pure-tone LFNs exceeding 100 Hz, further increased levels of cutaneous blood flow. Our wavelet-transform spectrum analysis of cutaneous blood flow next revealed that the nitric oxide (NO)-dependent and -independent vascular activities of the vascular endothelium were specifically increased by exposure to pure-tone LFN. Our animal study again indicated that exposure to pure-tone LFN increased cutaneous blood flow in mice with impairments of bilateral inner ears as well as cutaneous blood flow in control mice, suggesting a limited effect of inner ear function on the LFN-mediated increase in cutaneous blood flow. The NO-dependent suppressive effect of pure-tone LFN on cutaneous blood flow was confirmed by inhibition of vascular endothelial activity through intravenous injection of an NO inhibitor in wild-type mice. Taken together, the results of this study demonstrated that the vascular endothelium is a target tissue of LFN and that NO is an effector of the LFN-mediated increase in cutaneous blood flow. Since improvement of peripheral circulation could generally promote human health, short-term exposure to LFN may be beneficial for health.
Collapse
Affiliation(s)
- Yuqi Deng
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Nobutaka Ohgami
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan.
| | - Takumi Kagawa
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Fitri Kurniasari
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Dijie Chen
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Masashi Kato
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Gokiso, Showa-ku, Nagoya 466-8555, Japan
| | - Akira Tazaki
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Masayo Aoki
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Hiroki Katsuta
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Keming Tong
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Yishuo Gu
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan
| | - Masashi Kato
- Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan.
| |
Collapse
|
7
|
Youngblood RT, Hafner BJ, Czerniecki JM, Larsen BG, Allyn KJ, Sanders JE. Mechanically and physiologically optimizing prosthetic elevated vacuum systems in people with transtibial amputation: a pilot study. JOURNAL OF PROSTHETICS AND ORTHOTICS : JPO 2022; 34:194-201. [PMID: 36582938 PMCID: PMC9793861 DOI: 10.1097/jpo.0000000000000396] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Introduction The most suitable elevated vacuum (EV) pressure may differ for each individual prosthesis user depending on suspension needs, socket fit, prosthetic components, and health. Mechanical and physiological effects of EV were evaluated in an effort to determine the optimal vacuum pressure for three individuals. Methods Instrumented EV sockets were created based on the participants' regular EV sockets. Inductive distance sensors were embedded into the wall of the socket at select locations to measure limb movement relative to the socket. Each participant conducted an activity protocol while limb movement, limb fluid volume, and user-reported comfort were measured at various socket vacuum pressure settings. Results Increased socket vacuum pressure resulted in reduced limb-socket displacement for each participant; however, 81-93% of limb movement was eliminated by a vacuum pressure setting of 12 (approximately -9 inHg). Relative limb-socket displacement by sensor location varied for each participant, suggesting distinct differences related to socket fit or residual limb tissue content. The rate of limb fluid volume change and the change in socket comfort did not consistently differ with socket vacuum pressure, suggesting a more complex relationship unique to each individual. Conclusions Practitioners may use individual responses to optimize socket vacuum pressure settings, balancing mechanical and physiological effects of EV for improved clinical outcomes.
Collapse
Affiliation(s)
| | - Brian J Hafner
- Department of Rehabilitation Medicine, University of Washington, Seattle, WA, USA
| | - Joseph M Czerniecki
- VA Center for Limb Loss and Mobility, VA Puget Sound Health Care System, Seattle, WA, USA
| | - Brian G Larsen
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Katheryn J Allyn
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Joan E Sanders
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| |
Collapse
|
8
|
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. Nat Biomed Eng 2021; 5:749-758. [PMID: 34272524 DOI: 10.1038/s41551-021-00763-4] [Citation(s) in RCA: 89] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 06/10/2021] [Indexed: 02/06/2023]
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Collapse
|
9
|
Soppi E, Knuuti J, Kalliokoski K. Positron emission tomography study of effects of two pressure-relieving support surfaces on pressure ulcer development. J Wound Care 2021; 30:54-62. [PMID: 33439081 DOI: 10.12968/jowc.2021.30.1.54] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
OBJECTIVE To study the pathophysiological cascade of pressure ulcer (PU) development consisting of tissue deformation, inflammation and hypoxia. METHOD In this crossover study, deformation was measured with computerised tomography (CT) linked with contact area reflecting immersion and envelopment. Inflammation and hypoxia were measured using subepidermal moisture (SEM), skin temperature and tissue perfusion with positron emission tomography. These variables were investigated under 90 minutes of pressure exposure caused by two functionally different support surfaces-a regular foam mattress and a minimum pressure air (MPA) mattress. RESULTS A total of eight healthy volunteers took part in the study. There was major tissue deformation when the participants lay on a foam mattress while the tissues retained their original shape on the MPA mattress (p<0.0001). During the pressure exposure, the skin temperature increased significantly on both support surfaces but the final temperature on the foam mattress was about 1oC higher than on the MPA mattress (p<0.0001). SEM increased on both support surfaces compared with an unexposed reference site, but the cause may be different between the two support surfaces. Tissue perfusion was lowest in the skin followed by subcutaneous tissues and highest in the muscles. The pressure exposure did not cause any substantial changes in perfusion. The results showed that tissue deformation was more pronounced, the support surface contact area (envelopment), was smaller and the skin temperature higher on the foam mattress than on the MPA mattress, without significant differences in tissue perfusion. CONCLUSION In this study, the MPA mattress support surface had mechanobiological properties that counteracted tissue deformation and thereby may prevent PUs.
Collapse
Affiliation(s)
- Esa Soppi
- Outpatient Clinic, Eira Hospital, Laivurinkatu 29, FI-00150 Helsinki, Finland
| | - Juhani Knuuti
- Turku PET Centre, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, Finland
| | - Kari Kalliokoski
- Turku PET Centre, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, Finland
| |
Collapse
|
10
|
Suvorov NB, Belov AV, Kuliabin KG, Anisimov AA, Sergeev TV, Markelov OA. High Precision Human Skin Temperature Fluctuations Measuring Instrument. SENSORS 2021; 21:s21124101. [PMID: 34203648 PMCID: PMC8232319 DOI: 10.3390/s21124101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/06/2021] [Accepted: 06/11/2021] [Indexed: 11/30/2022]
Abstract
This paper describes the experimental results of testing a prototype of a high precision human skin rapid temperature fluctuations measuring instrument. Based on the author’s work, an original circuit solution on a miniature semiconductor diode sensor has been designed. The proposed circuitry provides operation in the full voltage range with automatic setting and holding the operating point, as well as the necessary slope of the conversion coefficient (up to 2300 mV/°C), which makes it possible to register fast temperature oscillations from the surface of the human body and other biological objects. Simulation results in the Microcap 12 software and laboratory tests have confirmed all declared design specifications: temperature resolution of 0.01 °C, transducer thermal time constant of 0.05 s. An original thermostat and an experimental setup for the simultaneous registration of the electrocardiogram, pulse wave signals from the Biopac polygraph MP36 and a signal of temperature oscillations from the prototype thermometer have been designed for further investigations. The preliminary test results indicates that using the designed measuring instrument gives a possibility to provide an in-depth study of the relationship between micro- and macro-blood circulations manifested in skin temperature fluctuations.
Collapse
Affiliation(s)
- Nikolai B. Suvorov
- Department of Ecological Physiology, Federal State Budgetary Scientific Institution “Institute of Experimental Medicine”, 12 Acad. Pavlov Str., 197376 Saint Petersburg, Russia; (N.B.S.); (A.V.B.); (K.G.K.); (A.A.A.); (T.V.S.)
| | - Alexander V. Belov
- Department of Ecological Physiology, Federal State Budgetary Scientific Institution “Institute of Experimental Medicine”, 12 Acad. Pavlov Str., 197376 Saint Petersburg, Russia; (N.B.S.); (A.V.B.); (K.G.K.); (A.A.A.); (T.V.S.)
| | - Konstantin G. Kuliabin
- Department of Ecological Physiology, Federal State Budgetary Scientific Institution “Institute of Experimental Medicine”, 12 Acad. Pavlov Str., 197376 Saint Petersburg, Russia; (N.B.S.); (A.V.B.); (K.G.K.); (A.A.A.); (T.V.S.)
| | - Aleksei A. Anisimov
- Department of Ecological Physiology, Federal State Budgetary Scientific Institution “Institute of Experimental Medicine”, 12 Acad. Pavlov Str., 197376 Saint Petersburg, Russia; (N.B.S.); (A.V.B.); (K.G.K.); (A.A.A.); (T.V.S.)
- Department of Biomedical Engineering, Saint Petersburg Electrotechnical University “LETI”, 5 Prof. Popov Str., 197376 Saint Petersburg, Russia
| | - Timofei V. Sergeev
- Department of Ecological Physiology, Federal State Budgetary Scientific Institution “Institute of Experimental Medicine”, 12 Acad. Pavlov Str., 197376 Saint Petersburg, Russia; (N.B.S.); (A.V.B.); (K.G.K.); (A.A.A.); (T.V.S.)
- Department of Biomedical Engineering, Saint Petersburg Electrotechnical University “LETI”, 5 Prof. Popov Str., 197376 Saint Petersburg, Russia
| | - Oleg A. Markelov
- Department of Biomedical Engineering, Saint Petersburg Electrotechnical University “LETI”, 5 Prof. Popov Str., 197376 Saint Petersburg, Russia
- Correspondence:
| |
Collapse
|
11
|
Qiu L, Ouyang Y, Feng Y, Zhang X, Wang X. In vivo skin thermophysical property testing technology using flexible thermosensor-based 3 ω method. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER 2020; 163:120550. [PMID: 33071298 PMCID: PMC7546650 DOI: 10.1016/j.ijheatmasstransfer.2020.120550] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 09/18/2020] [Accepted: 09/28/2020] [Indexed: 05/05/2023]
Abstract
Thermophysical properties of human skin surface and subsurface can reflect the hydration state of the skin and the blood flow rate in the near surface microvessels, which reveals important physiological information related to dermatology and overall health status of human body. Although a few techniques have been developed to measure these signs, complicated devices are required and the subjects need to be completely fixed during the test period. Here, a flexible thermosensor-based 3ω technology was used to monitor thermal conductivity of human skins at different states. Through the analysis of these characteristics, the corresponding physiological state can be established, which can provide a new detection method for the evaluation or prediction of human health status.
Collapse
Affiliation(s)
- Lin Qiu
- School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing, 100083, China
- Beijing Key Laboratory of Energy Saving and Emission Reduction for Metallurgical Industry, University of Science and Technology Beijing, Beijing, 100083, China
| | - Yuxin Ouyang
- School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing, 100083, China
- Beijing Key Laboratory of Energy Saving and Emission Reduction for Metallurgical Industry, University of Science and Technology Beijing, Beijing, 100083, China
| | - Yanhui Feng
- School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing, 100083, China
- Beijing Key Laboratory of Energy Saving and Emission Reduction for Metallurgical Industry, University of Science and Technology Beijing, Beijing, 100083, China
| | - Xinxin Zhang
- School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing, 100083, China
- Beijing Key Laboratory of Energy Saving and Emission Reduction for Metallurgical Industry, University of Science and Technology Beijing, Beijing, 100083, China
| | - Xiaotian Wang
- School of Chemistry, Beihang University, Beijing, 100191, China
| |
Collapse
|
12
|
Mawhinney C, Heinonen I, Low DA, Han C, Jones H, Kalliokoski KK, Kirjavainen A, Kemppainen J, Di Salvo V, Weston M, Cable T, Gregson W. Changes in quadriceps femoris muscle perfusion following different degrees of cold-water immersion. J Appl Physiol (1985) 2020; 128:1392-1401. [PMID: 32352343 DOI: 10.1152/japplphysiol.00833.2019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
We examined the influence of graded cold-water immersion (CWI) on global and regional quadriceps muscle perfusion with positron emission tomography (PET) and [15O]H2O. In 30 healthy men [33 ± 8 yr; 81 ± 10 kg; 184 ± 5 cm; percentage body fat: 13 ± 5%; peak oxygen uptake (V̇o2peak): 47 ± 8 mL·kg-1·min-1] quadriceps perfusion, thigh and calf cutaneous vascular conductance (CVC), intestinal, muscle, and local skin temperatures, thermal comfort, mean arterial pressure, and heart rate were assessed before and after 10 min of CWI at 8°C, 15°C, or 22°C. Global quadriceps perfusion did not change beyond a clinically relevant threshold (0.75 mL·100 g·min-1) in any condition and was similar between conditions {range of differences [95% confidence interval (CI)]: 0.1 mL·100 g·min-1 (-0.9 to 1.2 mL·100 g·min-1) to 0.9 mL·100 g·min-1 (-0.2 to 1.9 mL·100 g·min-1)}. Muscle perfusion was greater in vastus intermedius (VI) compared with vastus lateralis (VL) (2.2 mL·100 g·min-1; 95% CI 1.5 to 3.0 mL·100 g·min-1) and rectus femoris (RF) (2.2 mL·100 g·min-1; 1.4 to 2.9 mL·100 g·min-1). A clinically relevant increase in VI muscle perfusion after immersion at 8°C and a decrease in RF muscle perfusion at 15°C were observed. A clinically relevant increase in perfusion was observed in VI in 8°C compared with 22°C water (2.3 mL·100 g·min-1; 1.1 to 3.5 mL·100 g·min-1). There were no clinically relevant between-condition differences in thigh CVC. Our findings suggest that CWI (8-22°C) does not reduce global quadriceps muscle perfusion to a clinically relevant extent; however, colder water increases (8°C) deep muscle perfusion and reduces (15°C) superficial muscle (RF) perfusion in the quadriceps muscle.NEW & NOTEWORTHY Using positron emission tomography, we report for the first time muscle perfusion heterogeneity in the quadriceps femoris in response to different degrees of cold-water immersion (CWI). Noxious CWI temperatures (8°C) increase perfusion in the deep quadriceps muscle, whereas superficial quadriceps muscle perfusion is reduced in cooler (15°C) water. Therefore, these data have important implications for the selection of CWI approaches used in the treatment of soft tissue injury, while also increasing our understanding of the potential mechanisms underpinning CWI.
Collapse
Affiliation(s)
- Chris Mawhinney
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom.,College of Sports Science and Technology, Mahidol University, Salaya, Thailand
| | - Ilkka Heinonen
- Turku PET Centre, University of Turku and Turku University Hospital, Turku, Finland.,Department of Clinical Physiology and Nuclear Medicine, University of Turku, Turku, Finland.,Rydberg Laboratory of Applied Sciences, University of Halmstad, Halmstad, Sweden
| | - David A Low
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom
| | - Chunlei Han
- Turku PET Centre, University of Turku and Turku University Hospital, Turku, Finland
| | - Helen Jones
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom
| | - Kari K Kalliokoski
- Turku PET Centre, University of Turku and Turku University Hospital, Turku, Finland
| | - Anna Kirjavainen
- Turku PET Centre, University of Turku and Turku University Hospital, Turku, Finland
| | - Jukka Kemppainen
- Turku PET Centre, University of Turku and Turku University Hospital, Turku, Finland
| | - Valter Di Salvo
- Football Performance and Science Department, Aspire Academy, Doha, Qatar
| | - Matthew Weston
- School of Health and Social Care, Teesside University, Middlesbrough, United Kingdom.,Football Performance and Science Department, Aspire Academy, Doha, Qatar
| | - Tim Cable
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Warren Gregson
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom.,Football Performance and Science Department, Aspire Academy, Doha, Qatar
| |
Collapse
|
13
|
Banerjee G, Briggs M, Johnson MI. The immediate effects of kinesiology taping on cutaneous blood flow in healthy humans under resting conditions: A randomised controlled repeated-measures laboratory study. PLoS One 2020; 15:e0229386. [PMID: 32084245 PMCID: PMC7034885 DOI: 10.1371/journal.pone.0229386] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 02/05/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Kinesiology taping (KT) is used in musculoskeletal practice for preventive and rehabilitative purposes. It is claimed that KT improves blood flow in the microcirculation by creating skin convolutions and that this reduces swelling and facilitates healing of musculoskeletal injuries. There is a paucity of physiological studies evaluating the effect of KT on cutaneous blood microcirculation. OBJECTIVES The purpose of this parallel-group controlled laboratory repeated measures design study was to evaluate the effects of KT on cutaneous blood microcirculation in healthy human adults using a dual wavelength (infrared and visible-red) laser Doppler Imaging (LDI) system. KT was compared with rigid taping and no taping controls to isolate the effects associated with the elasticity of KT. METHODS Forty-five healthy male and female human adults were allocated to one of the three interventions using constrained randomisation following the pre-intervention measurement: (i) KT (ii) ST (standard taping) (iii) NT (no taping). Cutaneous blood perfusion was measured using LDI in the ventral surface of forearm at pre-intervention, during-intervention and post-intervention in a normothermic environment at resting conditions. RESULTS Mixed ANOVA of both infrared and visible-red datasets revealed no statistically significant interaction between Intervention and Time. There was statistically significant main effect for Time but not Intervention. CONCLUSION KT does not increase cutaneous blood microcirculation in healthy human adults under resting physiological conditions in a normothermic environment. On the contrary, evidence suggests that taping, regardless of the elasticity in the tape, is associated with immediate reductions in cutaneous blood flow.
Collapse
Affiliation(s)
- Gourav Banerjee
- Centre for Pain Research, School of Clinical and Applied Sciences, Leeds Beckett University, Leeds, England, United Kingdom
- * E-mail:
| | - Michelle Briggs
- Division of Nursing, Midwifery and Social Work, School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, England, United Kingdom
| | - Mark I. Johnson
- Centre for Pain Research, School of Clinical and Applied Sciences, Leeds Beckett University, Leeds, England, United Kingdom
| |
Collapse
|
14
|
Ray TR, Choi J, Bandodkar AJ, Krishnan S, Gutruf P, Tian L, Ghaffari R, Rogers JA. Bio-Integrated Wearable Systems: A Comprehensive Review. Chem Rev 2019; 119:5461-5533. [PMID: 30689360 DOI: 10.1021/acs.chemrev.8b00573] [Citation(s) in RCA: 460] [Impact Index Per Article: 76.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Bio-integrated wearable systems can measure a broad range of biophysical, biochemical, and environmental signals to provide critical insights into overall health status and to quantify human performance. Recent advances in material science, chemical analysis techniques, device designs, and assembly methods form the foundations for a uniquely differentiated type of wearable technology, characterized by noninvasive, intimate integration with the soft, curved, time-dynamic surfaces of the body. This review summarizes the latest advances in this emerging field of "bio-integrated" technologies in a comprehensive manner that connects fundamental developments in chemistry, material science, and engineering with sensing technologies that have the potential for widespread deployment and societal benefit in human health care. An introduction to the chemistries and materials for the active components of these systems contextualizes essential design considerations for sensors and associated platforms that appear in following sections. The subsequent content highlights the most advanced biosensors, classified according to their ability to capture biophysical, biochemical, and environmental information. Additional sections feature schemes for electrically powering these sensors and strategies for achieving fully integrated, wireless systems. The review concludes with an overview of key remaining challenges and a summary of opportunities where advances in materials chemistry will be critically important for continued progress.
Collapse
Affiliation(s)
- Tyler R Ray
- Northwestern University , 2145 Sheridan Road , Evanston , Illinois 60208 , United States
| | - Jungil Choi
- Northwestern University , 2145 Sheridan Road , Evanston , Illinois 60208 , United States
| | - Amay J Bandodkar
- Northwestern University , 2145 Sheridan Road , Evanston , Illinois 60208 , United States
| | - Siddharth Krishnan
- Northwestern University , 2145 Sheridan Road , Evanston , Illinois 60208 , United States
| | - Philipp Gutruf
- Department of Biomedical Engineering University of Arizona Tucson , Arizona 85721 , United States
| | - Limei Tian
- Department of Biomedical Engineering , Texas A&M University , College Station , Texas 77843 , United States
| | - Roozbeh Ghaffari
- Northwestern University , 2145 Sheridan Road , Evanston , Illinois 60208 , United States
| | - John A Rogers
- Northwestern University , 2145 Sheridan Road , Evanston , Illinois 60208 , United States
| |
Collapse
|
15
|
Joshi VS, Joshi SS, Maruthy. Systemic and Local Effects of Warm Oxygen Exposure to the Lower Extremities in Healthy Volunteers. J Clin Diagn Res 2017; 11:CC01-CC03. [PMID: 28571131 DOI: 10.7860/jcdr/2017/23603.9679] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 12/23/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Warmth to the extremity is known to improve the cutaneous blood flow and tissue perfusion. Oxygen is essential for healing of chronic wounds. Topical oxygen therapy has become standard therapy in management of lower extremity wounds. A combination of local heat and oxygen is likely to be beneficial in many clinical scenarios of non-healing wounds without any systemic effects. AIM To evaluate the local and systemic effects of the exposure of extremity to warm oxygen in healthy volunteers. MATERIALS AND METHODS Thirty one volunteers were included in the study. The index foot was exposed to oxygen 7l/min, 93%-95% concentration at temperature of 43oC for 90 minutes with the device. The following parameters such as basal and periprocedural blood pressure, body temperature, heart rate, 24 lead ECG, temperatures at foot and plethysmographic waveforms from the index foot were measured. A NRS-11 questionnaire was asked to the patient to rate his or her pain from 0 to 10 and documented by health care worker at the end of the session. RESULTS The skin temperature of index foot reached to 34oC from 32.9oC, (p=0.011). The average pulse amplitude changed from 39.8 mV to 79.8 mV over the duration of the experiment (p< 0.001). Overall heart rate and core body temperature decreased and not much change in blood pressure. CONCLUSION The result of the study can be extrapolated to the healing of chronic non healing wounds using warm oxygen therapy. Further studies are required on patient population to prove benefits in clinical settings.
Collapse
Affiliation(s)
- Vidya Sunil Joshi
- Associate Professor, Department of Physiology, Vydehi Institute of Medical Sciences and Research, Bengaluru, Karnataka, India
| | - Sunil Subhash Joshi
- Associate Professor, Department of Vascular Surgery, St Johns Medical College Hospital, Sarjapur Road, Bengaluru, Karnataka, India
| | - Maruthy
- Professor, Department of Physiology, Narayana Medical College, Nellore, Andhra Pradesh, India
| |
Collapse
|
16
|
McAuliffe S, McCreesh K, Culloty F, Purtill H, O'Sullivan K. Can ultrasound imaging predict the development of Achilles and patellar tendinopathy? A systematic review and meta-analysis. Br J Sports Med 2016; 50:1516-1523. [DOI: 10.1136/bjsports-2016-096288] [Citation(s) in RCA: 101] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/24/2016] [Indexed: 12/22/2022]
|
17
|
Hu G, Zhang Q, Ivkovic V, Strangman GE. Ambulatory diffuse optical tomography and multimodality physiological monitoring system for muscle and exercise applications. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:091314. [PMID: 27467190 DOI: 10.1117/1.jbo.21.9.091314] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 07/08/2016] [Indexed: 05/09/2023]
Abstract
Ambulatory diffuse optical tomography (aDOT) is based on near-infrared spectroscopy (NIRS) and enables three-dimensional imaging of regional hemodynamics and oxygen consumption during a person’s normal activities. Although NIRS has been previously used for muscle assessment, it has been notably limited in terms of the number of channels measured, the extent to which subjects can be ambulatory, and/or the ability to simultaneously acquire synchronized auxiliary data such as electromyography (EMG) or electrocardiography (ECG). We describe the development of a prototype aDOT system, called NINscan-M, capable of ambulatory tomographic imaging as well as simultaneous auxiliary multimodal physiological monitoring. Powered by four AA size batteries and weighing 577 g, the NINscan-M prototype can synchronously record 64-channel NIRS imaging data, eight channels of EMG, ECG, or other analog signals, plus force, acceleration, rotation, and temperature for 24+ h at up to 250 Hz. We describe the system’s design, characterization, and performance characteristics. We also describe examples of isometric, cycle ergometer, and free-running ambulatory exercise to demonstrate tomographic imaging at 25 Hz. NINscan-M represents a multiuse tool for muscle physiology studies as well as clinical muscle assessment.
Collapse
Affiliation(s)
- Gang Hu
- Harvard Medical School, Massachusetts General Hospital, Neural Systems Group, Building 149, 13th Street, Charlestown, Massachusetts 02129, United States
| | - Quan Zhang
- Harvard Medical School, Massachusetts General Hospital, Neural Systems Group, Building 149, 13th Street, Charlestown, Massachusetts 02129, United StatesbBaylor College of Medicine, Center for Space Medicine, 6500 Main Street, Houston, Texas 77030, United
| | - Vladimir Ivkovic
- Harvard Medical School, Massachusetts General Hospital, Neural Systems Group, Building 149, 13th Street, Charlestown, Massachusetts 02129, United States
| | - Gary E Strangman
- Harvard Medical School, Massachusetts General Hospital, Neural Systems Group, Building 149, 13th Street, Charlestown, Massachusetts 02129, United StatesbBaylor College of Medicine, Center for Space Medicine, 6500 Main Street, Houston, Texas 77030, United
| |
Collapse
|
18
|
Webb RC, Ma Y, Krishnan S, Li Y, Yoon S, Guo X, Feng X, Shi Y, Seidel M, Cho NH, Kurniawan J, Ahad J, Sheth N, Kim J, Taylor VI JG, Darlington T, Chang K, Huang W, Ayers J, Gruebele A, Pielak RM, Slepian MJ, Huang Y, Gorbach AM, Rogers JA. Epidermal devices for noninvasive, precise, and continuous mapping of macrovascular and microvascular blood flow. SCIENCE ADVANCES 2015; 1:e1500701. [PMID: 26601309 PMCID: PMC4646823 DOI: 10.1126/sciadv.1500701] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Accepted: 09/01/2015] [Indexed: 05/17/2023]
Abstract
Continuous monitoring of variations in blood flow is vital in assessing the status of microvascular and macrovascular beds for a wide range of clinical and research scenarios. Although a variety of techniques exist, most require complete immobilization of the subject, thereby limiting their utility to hospital or clinical settings. Those that can be rendered in wearable formats suffer from limited accuracy, motion artifacts, and other shortcomings that follow from an inability to achieve intimate, noninvasive mechanical linkage of sensors with the surface of the skin. We introduce an ultrathin, soft, skin-conforming sensor technology that offers advanced capabilities in continuous and precise blood flow mapping. Systematic work establishes a set of experimental procedures and theoretical models for quantitative measurements and guidelines in design and operation. Experimental studies on human subjects, including validation with measurements performed using state-of-the-art clinical techniques, demonstrate sensitive and accurate assessment of both macrovascular and microvascular flow under a range of physiological conditions. Refined operational modes eliminate long-term drifts and reduce power consumption, thereby providing steps toward the use of this technology for continuous monitoring during daily activities.
Collapse
Affiliation(s)
- R. Chad Webb
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Yinji Ma
- Departments of Civil and Environmental Engineering, and Mechanical Engineering, Center for Engineering and Health, and Skin Disease Research Center, Northwestern University, Evanston, IL 60208, USA
- Department of Engineering Mechanics, Center for Mechanics and Materials, Tsinghua University, Beijing 100084, China
| | - Siddharth Krishnan
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Yuhang Li
- Departments of Civil and Environmental Engineering, and Mechanical Engineering, Center for Engineering and Health, and Skin Disease Research Center, Northwestern University, Evanston, IL 60208, USA
- Institute of Solid Mechanics, Beihang University (BUAA), Beijing 100191, China
| | - Stephen Yoon
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Xiaogang Guo
- Departments of Civil and Environmental Engineering, and Mechanical Engineering, Center for Engineering and Health, and Skin Disease Research Center, Northwestern University, Evanston, IL 60208, USA
- College of Aerospace and Civil Engineering, Harbin Engineering University, Harbin 150001, China
| | - Xue Feng
- Department of Engineering Mechanics, Center for Mechanics and Materials, Tsinghua University, Beijing 100084, China
| | - Yan Shi
- Departments of Civil and Environmental Engineering, and Mechanical Engineering, Center for Engineering and Health, and Skin Disease Research Center, Northwestern University, Evanston, IL 60208, USA
- State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Miles Seidel
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Nam Heon Cho
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Jonas Kurniawan
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - James Ahad
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Niral Sheth
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Joseph Kim
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - James G. Taylor VI
- Genomic Medicine Section, Hematology Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
| | - Tom Darlington
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Ken Chang
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - Weizhong Huang
- Department of Electrical and Computer Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Joshua Ayers
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Alexander Gruebele
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Rafal M. Pielak
- L’Oréal California Research Center, 953 Indiana Street, San Francisco, CA 94107, USA
| | - Marvin J. Slepian
- Department of Medicine, Sarver Heart Center, and Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85724, USA
| | - Yonggang Huang
- Departments of Civil and Environmental Engineering, and Mechanical Engineering, Center for Engineering and Health, and Skin Disease Research Center, Northwestern University, Evanston, IL 60208, USA
| | - Alexander M. Gorbach
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA
| | - John A. Rogers
- Department of Materials Science and Engineering, and Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Corresponding author. E-mail:
| |
Collapse
|
19
|
Laymon M, Petrofsky J, McKivigan J, Lee H, Yim J. Effect of heat, cold, and pressure on the transverse carpal ligament and median nerve: a pilot study. Med Sci Monit 2015; 21:446-51. [PMID: 25669437 PMCID: PMC4335578 DOI: 10.12659/msm.892462] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Background This study quantified the effects of heat, cold, and pressure on the median nerve and transverse carpal ligament in subjects without carpal tunnel syndrome. Material/Methods Subjects were individuals ages 20–50 who had no symptoms of carpal tunnel disease. Imaging ultrasound was used to measure the clearance around the median nerve, transverse ligament elasticity, nerve conduction velocity, thickness of the carpal ligament, and area of the median nerve. Pressure was applied to the carpal ligament to assess the effects of increasing pressure on these structures. On 3 separate days, 10 subjects had ThermaCare heat or cold packs applied, for either 60 or 120 minutes for heat or 20 minutes for cold, to the palmer surface of the hand. Results Tissue changes were recorded as a response to pressure applied at 0, 5, 10, and 20 N. The size of the nerve and ligaments were not significantly altered by pressure with the hand at room temperature and after cold exposure. After heat, the nerve, ligaments, and tendons showed significantly more elasticity. Conclusions Application of cold to the hand may reduce compression of the carpal ligament and nerve.
Collapse
Affiliation(s)
- Michael Laymon
- School of Physical Therapy, Touro University Nevada, Henderson, NV, USA
| | - Jerrold Petrofsky
- Department of Physical Therapy, School of Allied Health Professions, Loma Linda University, Loma Linda, CA, USA
| | - James McKivigan
- School of Physical Therapy, Touro University Nevada, Henderson, NV, USA
| | - Haneul Lee
- Department of Physical Therapy, School of Allied Health Professions, Loma Linda University, Loma Linda, CA, USA
| | - JongEun Yim
- Department of Physical Therapy, Sahmyook University, Seoul, Korea
| |
Collapse
|
20
|
Manevski N, Swart P, Balavenkatraman KK, Bertschi B, Camenisch G, Kretz O, Schiller H, Walles M, Ling B, Wettstein R, Schaefer DJ, Itin P, Ashton-Chess J, Pognan F, Wolf A, Litherland K. Phase II metabolism in human skin: skin explants show full coverage for glucuronidation, sulfation, N-acetylation, catechol methylation, and glutathione conjugation. Drug Metab Dispos 2014; 43:126-39. [PMID: 25339109 DOI: 10.1124/dmd.114.060350] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Although skin is the largest organ of the human body, cutaneous drug metabolism is often overlooked, and existing experimental models are insufficiently validated. This proof-of-concept study investigated phase II biotransformation of 11 test substrates in fresh full-thickness human skin explants, a model containing all skin cell types. Results show that skin explants have significant capacity for glucuronidation, sulfation, N-acetylation, catechol methylation, and glutathione conjugation. Novel skin metabolites were identified, including acyl glucuronides of indomethacin and diclofenac, glucuronides of 17β-estradiol, N-acetylprocainamide, and methoxy derivatives of 4-nitrocatechol and 2,3-dihydroxynaphthalene. Measured activities for 10 μM substrate incubations spanned a 1000-fold: from the highest 4.758 pmol·mg skin(-1)·h(-1) for p-toluidine N-acetylation to the lowest 0.006 pmol·mg skin(-1)·h(-1) for 17β-estradiol 17-glucuronidation. Interindividual variability was 1.4- to 13.0-fold, the highest being 4-methylumbelliferone and diclofenac glucuronidation. Reaction rates were generally linear up to 4 hours, although 24-hour incubations enabled detection of metabolites in trace amounts. All reactions were unaffected by the inclusion of cosubstrates, and freezing of the fresh skin led to loss of glucuronidation activity. The predicted whole-skin intrinsic metabolic clearances were significantly lower compared with corresponding whole-liver intrinsic clearances, suggesting a relatively limited contribution of the skin to the body's total systemic phase II enzyme-mediated metabolic clearance. Nevertheless, the fresh full-thickness skin explants represent a suitable model to study cutaneous phase II metabolism not only in drug elimination but also in toxicity, as formation of acyl glucuronides and sulfate conjugates could play a role in skin adverse reactions.
Collapse
Affiliation(s)
- Nenad Manevski
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Piet Swart
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Kamal Kumar Balavenkatraman
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Barbara Bertschi
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Gian Camenisch
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Olivier Kretz
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Hilmar Schiller
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Markus Walles
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Barbara Ling
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Reto Wettstein
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Dirk J Schaefer
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Peter Itin
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Joanna Ashton-Chess
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Francois Pognan
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Armin Wolf
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| | - Karine Litherland
- Drug Metabolism and Pharmacokinetics (N.M., P.S., G.C., O.K., H.S., M.W., K.L.), Pre-clinical Safety (K.K.B., B.B., F.P., A.W.), and Clinical Sciences and Innovation Translational Medicine (J.A.-C.), Novartis Institutes for BioMedical Research, Novartis Pharma, Basel, Switzerland; and Department of Plastic, Reconstructive, Aesthetic and Hand Surgery (B.L., R.W., D.J.S.), and Department of Dermatology (P.I.), University Hospital Basel, Basel, Switzerland
| |
Collapse
|
21
|
Petrofsky JS, Alshammari F, Bains GS, Khowailed IA, Lee H, Kuderu YN, Lodha RD, Rodrigues S, Nguyen D, Potnis PA, Deshpande PP, Yim JE, Berk L. What is more damaging to vascular endothelial function: Diabetes, age, high BMI, or all of the above? Med Sci Monit 2013; 19:257-63. [PMID: 23666370 PMCID: PMC3659113 DOI: 10.12659/msm.883878] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2012] [Accepted: 12/10/2012] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND It is well established that there is a reduction in the skin blood flow (SBF) in response to heat with age and diabetes. While it is known that high BMI creates a stress on the cardiovascular system and increases the risk of all cause of morbidity and mortality, little is known of the effect of high BMI on SBF response to heat. Since diabetes is associated with age and a higher BMI, the interrelationship between age, BMI and SBF needs to be investigated to better understand the contribution diabetes alone has to endothelial impairment. MATERIAL AND METHODS This study examined the SBF to heat in young and old people with low and high BMI and people with diabetes with high BMI to determine the contribution these variables have on SBF. Subjects were ten young and older people with BMI <20 and ten young and older people with BMI >20 and ten subjects with diabetes with BMI >20. The SBF response, above the quadriceps, was determined during a 6 minutes exposure to heat at 44°C. RESULTS Even in young people, SBF after the stress of heat exposure was reduced in subjects with a high BMI. The effect of BMI was greatest in young people and lowest in older people and people with diabetes; in people with diabetes, BMI was a more significant variable than diabetes in causing impairment of blood flow to heat. BMI, for example, was responsible for 49% of the reduction in blood flow after stress heat exposure (R=-0.7) while ageing only accounted for 16% of the blood flow reduction (R=-0.397). CONCLUSIONS These results would suggest the importance of keeping BMI low not only in people with diabetes to minimize further circulatory vascular damage, but also in young people to diminish long term circulatory vascular compromise.
Collapse
Affiliation(s)
- Jerrold Scott Petrofsky
- Department of Physical Therapy, School of Allied Health Professions, Loma Linda University, Loma LInda, CA, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Petrofsky JS, Laymon M, Berk L, Al-Nakhli HH, Banh A, Eisentrout A, Tokar A, Valentine M, Batt J. Pilot study: physiological evidence that heat reduces pain and muscle damage in delayed-onset muscle soreness. ACTA ACUST UNITED AC 2012. [DOI: 10.2217/cpr.12.58] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|