1
|
Sanai F, Sahid AS, Huvanandana J, Spoa S, Boyle LH, Hribar J, Wang DTY, Kwan B, Colagiuri S, Cox SJ, Telfer TJ. Evaluation of a Continuous Blood Glucose Monitor: A Novel and Non-Invasive Wearable Using Bioimpedance Technology. J Diabetes Sci Technol 2023; 17:336-344. [PMID: 34711074 PMCID: PMC10012362 DOI: 10.1177/19322968211054110] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Frequent blood glucose level (BGL) monitoring is essential for effective diabetes management. Poor compliance is common due to the painful finger pricking or subcutaneous lancet implantation required from existing technologies. There are currently no commercially available non-invasive devices that can effectively measure BGL. In this real-world study, a prototype non-invasive continuous glucose monitoring system (NI-CGM) developed as a wearable ring was used to collect bioimpedance data. The aim was to develop a mathematical model that could use these bioimpedance data to estimate BGL in real time. METHODS The prototype NI-CGM was worn by 14 adult participants with type 2 diabetes for 14 days in an observational clinical study. Bioimpedance data were collected alongside paired BGL measurements taken with a Food and Drug Administration (FDA)-approved self-monitoring blood glucose (SMBG) meter and an FDA-approved CGM. The SMBG meter data were used to improve CGM accuracy, and CGM data to develop the mathematical model. RESULTS A gradient boosted model was developed using a randomized 80-20 training-test split of data. The estimated BGL from the model had a Mean Absolute Relative Difference (MARD) of 17.9%, with the Parkes error grid (PEG) analysis showing 99% of values in clinically acceptable zones A and B. CONCLUSIONS This study demonstrated the reliability of the prototype NI-CGM at collecting bioimpedance data in a real-world scenario. These data were used to train a model that could successfully estimate BGL with a promising MARD and clinically relevant PEG result. These results will enable continued development of the prototype NI-CGM as a wearable ring.
Collapse
Affiliation(s)
- Farid Sanai
- Scimita Ventures Pty Ltd, Sydney, NSW,
Australia
| | | | | | - Sandra Spoa
- Scimita Ventures Pty Ltd, Sydney, NSW,
Australia
| | | | | | | | | | - Stephen Colagiuri
- Boden Collaboration of Obesity,
Nutrition, Exercise and Eating Disorders, The University of Sydney, Sydney, NSW,
Australia
- WHO Collaborating Centre on Physical
Activity, Nutrition and Obesity, The University of Sydney, Sydney, NSW,
Australia
| | - Shane J. Cox
- Scimita Ventures Pty Ltd, Sydney, NSW,
Australia
| | - Thomas J. Telfer
- Scimita Ventures Pty Ltd, Sydney, NSW,
Australia
- Thomas J. Telfer, PhD (Medicine), BSc (Adv)
(Hons I), Scimita Ventures Pty Ltd, 31/2 Bishop Street, St Peters, Sydney, NSW
2044, Australia.
| |
Collapse
|
2
|
Fiedorova K, Augustynek M, Kubicek J, Kudrna P, Bibbo D. Review of present method of glucose from human blood and body fluids assessment. Biosens Bioelectron 2022; 211:114348. [DOI: 10.1016/j.bios.2022.114348] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 03/22/2022] [Accepted: 05/05/2022] [Indexed: 12/15/2022]
|
3
|
An overview of recent advances in insulin delivery and wearable technology for effective management of diabetes. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2022.103728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
4
|
Hwang YM, Kim JH. The first survey on patient needs for remote monitoring of cardiac implantable electronic device in South Korea. Medicine (Baltimore) 2022; 101:e29414. [PMID: 35687779 PMCID: PMC9276406 DOI: 10.1097/md.0000000000029414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 04/18/2022] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND/AIMS Studies showed that remote device monitoring reduced unnecessary outpatient visits and increased patient satisfaction. As there was no local research on remote monitoring (RM) in Korea, there was a lack of evidence for policy or insurance standards due to the lack of domestic data despite high demand by domestic arrhythmia experts. To establish the basis for patient satisfaction, economic efficiency, and safety of wireless monitoring, a survey-based study was planned. METHODS This was a single-university hospital survey. The satisfaction index was evaluated using a questionnaire to investigate patient satisfaction in outpatient clinics, economic efficiency (measured as home-to-clinic time, waiting time, and actual clinic time), and demand for RM in patients with implantable cardiac devices. The questionnaire was adopted and modified from the Survey on Telehealth Patient Experience by Bas-Villalobos, 2006 (modified Korean version 2.0 by You Mi Hwang, 2020). RESULTS Surveys were answered by 171 patients. The mean age of these patients was 71.2 ± 12.4 years. Based on the survey, home to clinic time was usually less than one h, mean waiting time in the hospital until clinic time ranged 42.6 ± 24.5 minutes, and mean clinic time ranged 3.1 ± 1.7 minutes. Based on the survey, patients favored RM over hospital visits with cardiac implantable electronic device follow-up mainly because of long travel times from home to clinic. CONCLUSION Based on the survey results, there is a clear need for RM in patients who have cardiac implantable electronic devices.
Collapse
Affiliation(s)
- You Mi Hwang
- Department of Cardiology, St.Vincent's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
- Catholic Research Institute for Intractable Cardiovascular Disease (CRID), College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Ji-Hoon Kim
- Department of Cardiology, St.Vincent's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
- Catholic Research Institute for Intractable Cardiovascular Disease (CRID), College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
5
|
Alhaddad AY, Aly H, Gad H, Al-Ali A, Sadasivuni KK, Cabibihan JJ, Malik RA. Sense and Learn: Recent Advances in Wearable Sensing and Machine Learning for Blood Glucose Monitoring and Trend-Detection. Front Bioeng Biotechnol 2022; 10:876672. [PMID: 35646863 PMCID: PMC9135106 DOI: 10.3389/fbioe.2022.876672] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 04/12/2022] [Indexed: 12/12/2022] Open
Abstract
Diabetes mellitus is characterized by elevated blood glucose levels, however patients with diabetes may also develop hypoglycemia due to treatment. There is an increasing demand for non-invasive blood glucose monitoring and trends detection amongst people with diabetes and healthy individuals, especially athletes. Wearable devices and non-invasive sensors for blood glucose monitoring have witnessed considerable advances. This review is an update on recent contributions utilizing novel sensing technologies over the past five years which include electrocardiogram, electromagnetic, bioimpedance, photoplethysmography, and acceleration measures as well as bodily fluid glucose sensors to monitor glucose and trend detection. We also review methods that use machine learning algorithms to predict blood glucose trends, especially for high risk events such as hypoglycemia. Convolutional and recurrent neural networks, support vector machines, and decision trees are examples of such machine learning algorithms. Finally, we address the key limitations and challenges of these studies and provide recommendations for future work.
Collapse
Affiliation(s)
- Ahmad Yaser Alhaddad
- Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
| | - Hussein Aly
- KINDI Center for Computing Research, Qatar University, Doha, Qatar
| | - Hoda Gad
- Weill Cornell Medicine - Qatar, Doha, Qatar
| | - Abdulaziz Al-Ali
- KINDI Center for Computing Research, Qatar University, Doha, Qatar
| | | | - John-John Cabibihan
- Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
| | - Rayaz A. Malik
- Weill Cornell Medicine - Qatar, Doha, Qatar
- *Correspondence: Rayaz A. Malik,
| |
Collapse
|
6
|
Xue Y, Thalmayer AS, Zeising S, Fischer G, Lübke M. Commercial and Scientific Solutions for Blood Glucose Monitoring-A Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:425. [PMID: 35062385 PMCID: PMC8780031 DOI: 10.3390/s22020425] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/27/2021] [Accepted: 12/29/2021] [Indexed: 12/25/2022]
Abstract
Diabetes is a chronic and, according to the state of the art, an incurable disease. Therefore, to treat diabetes, regular blood glucose monitoring is crucial since it is mandatory to mitigate the risk and incidence of hyperglycemia and hypoglycemia. Nowadays, it is common to use blood glucose meters or continuous glucose monitoring via stinging the skin, which is classified as invasive monitoring. In recent decades, non-invasive monitoring has been regarded as a dominant research field. In this paper, electrochemical and electromagnetic non-invasive blood glucose monitoring approaches will be discussed. Thereby, scientific sensor systems are compared to commercial devices by validating the sensor principle and investigating their performance utilizing the Clarke error grid. Additionally, the opportunities to enhance the overall accuracy and stability of non-invasive glucose sensing and even predict blood glucose development to avoid hyperglycemia and hypoglycemia using post-processing and sensor fusion are presented. Overall, the scientific approaches show a comparable accuracy in the Clarke error grid to that of the commercial ones. However, they are in different stages of development and, therefore, need improvement regarding parameter optimization, temperature dependency, or testing with blood under real conditions. Moreover, the size of scientific sensing solutions must be further reduced for a wearable monitoring system.
Collapse
Affiliation(s)
| | | | | | - Georg Fischer
- Institute for Electronics Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstr. 9, 91058 Erlangen, Germany; (Y.X.); (A.S.T.); (S.Z.)
| | - Maximilian Lübke
- Institute for Electronics Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstr. 9, 91058 Erlangen, Germany; (Y.X.); (A.S.T.); (S.Z.)
| |
Collapse
|
7
|
Smart-watch-programmed green-light-operated percutaneous control of therapeutic transgenes. Nat Commun 2021; 12:3388. [PMID: 34099676 PMCID: PMC8184832 DOI: 10.1038/s41467-021-23572-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 04/23/2021] [Indexed: 02/05/2023] Open
Abstract
Wearable smart electronic devices, such as smart watches, are generally equipped with green-light-emitting diodes, which are used for photoplethysmography to monitor a panoply of physical health parameters. Here, we present a traceless, green-light-operated, smart-watch-controlled mammalian gene switch (Glow Control), composed of an engineered membrane-tethered green-light-sensitive cobalamin-binding domain of Thermus thermophilus (TtCBD) CarH protein in combination with a synthetic cytosolic TtCBD-transactivator fusion protein, which manage translocation of TtCBD-transactivator into the nucleus to trigger expression of transgenes upon illumination. We show that Apple-Watch-programmed percutaneous remote control of implanted Glow-controlled engineered human cells can effectively treat experimental type-2 diabetes by producing and releasing human glucagon-like peptide-1 on demand. Directly interfacing wearable smart electronic devices with therapeutic gene expression will advance next-generation personalized therapies by linking biopharmaceutical interventions to the internet of things.
Collapse
|
8
|
Shokrekhodaei M, Quinones S. Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1251. [PMID: 32106464 PMCID: PMC7085605 DOI: 10.3390/s20051251] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 02/22/2020] [Accepted: 02/23/2020] [Indexed: 12/12/2022]
Abstract
Annual deaths in the U.S. attributed to diabetes are expected to increase from 280,210 in 2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has made it one of the major public health challenges around the world. Better management of diabetes has the potential to decrease yearly medical costs and deaths associated with the disease. Non-invasive methods are in high demand to take the place of the traditional finger prick method as they can facilitate continuous glucose monitoring. Research groups have been trying for decades to develop functional commercial non-invasive glucose measurement devices. The challenges associated with non-invasive glucose monitoring are the many factors that contribute to inaccurate readings. We identify and address the experimental and physiological challenges and provide recommendations to pave the way for a systematic pathway to a solution. We have reviewed and categorized non-invasive glucose measurement methods based on: (1) the intrinsic properties of glucose, (2) blood/tissue properties and (3) breath acetone analysis. This approach highlights potential critical commonalities among the challenges that act as barriers to future progress. The focus here is on the pertinent physiological aspects, remaining challenges, recent advancements and the sensors that have reached acceptable clinical accuracy.
Collapse
Affiliation(s)
- Maryamsadat Shokrekhodaei
- Department of Electrical and Computer Engineering, The University of Texas at El Paso, El Paso, TX 79968, USA
| | - Stella Quinones
- Department of Metallurgical, Materials and Biomedical Engineering, The University of Texas at El Paso, El Paso, TX 79968, USA;
| |
Collapse
|
9
|
He Y, Wu T, Tao S, Liu L, Wu J, Guo Q. NiCo
2
S
4
Nanowire‐Decorated Flexible Carbon Foam for Sensitive Glucose Sensors. ChemistrySelect 2020. [DOI: 10.1002/slct.201904201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Yi He
- Key Laboratory of Functional Small Organic Molecule Ministry of Education College of Chemistry and Chemical EngineeringJiangxi Normal University Nanchang, Jiangxi 330022 China
| | - Tingting Wu
- Key Laboratory of Functional Small Organic Molecule Ministry of Education College of Chemistry and Chemical EngineeringJiangxi Normal University Nanchang, Jiangxi 330022 China
| | - Shihan Tao
- Key Laboratory of Functional Small Organic Molecule Ministry of Education College of Chemistry and Chemical EngineeringJiangxi Normal University Nanchang, Jiangxi 330022 China
| | - Lijuan Liu
- Key Laboratory of Functional Small Organic Molecule Ministry of Education College of Chemistry and Chemical EngineeringJiangxi Normal University Nanchang, Jiangxi 330022 China
| | - Jun Wu
- Key Laboratory of Functional Small Organic Molecule Ministry of Education College of Chemistry and Chemical EngineeringJiangxi Normal University Nanchang, Jiangxi 330022 China
| | - Qiaohui Guo
- Key Laboratory of Functional Small Organic Molecule Ministry of Education College of Chemistry and Chemical EngineeringJiangxi Normal University Nanchang, Jiangxi 330022 China
| |
Collapse
|
10
|
Caduff A, Ben Ishai P, Feldman Y. Continuous noninvasive glucose monitoring; water as a relevant marker of glucose uptake in vivo. Biophys Rev 2019; 11:1017-1035. [PMID: 31741172 DOI: 10.1007/s12551-019-00601-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Accepted: 10/13/2019] [Indexed: 01/22/2023] Open
Abstract
With diabetes set to become the number 3 killer in the Western hemisphere and proportionally growing in other parts of the world, the subject of noninvasive monitoring of glucose dynamics in blood remains a "hot" topic, with the involvement of many groups worldwide. There is a plethora of techniques involved in this academic push, but the so-called multisensor system with an impedance-based core seems to feature increasingly strongly. However, the symmetrical structure of the glucose molecule and its shielding by the smaller dipoles of water would suggest that this option should be less enticing. Yet there is enough phenomenological evidence to suggest that impedance-based methods are truly sensitive to the biophysical effects of glucose variations in the blood. We have been trying to answer this very fundamental conundrum: "Why is impedance or dielectric spectroscopy sensitive to glucose concentration changes in the blood and why can this be done over a very broad frequency band, including microwaves?" The vistas for medical diagnostics are very enticing. There have been a significant number of papers published that look seriously at this problem. In this review, we want to summarize this body of research and the underlying mechanisms and propose a perspective toward utilizing the phenomena. It is our impression that the current world view on the dielectric response of glucose in solution, as outlined below, will support the further evolution and implementation toward practical noninvasive glucose monitoring solutions.
Collapse
Affiliation(s)
- Andreas Caduff
- Applied Physics Department and the Center for Electromagnetic Research and Characterization, The Hebrew University of Jerusalem, 91904, Jerusalem, Israel
| | - Paul Ben Ishai
- Department of Physics, Ariel University, 40700, Ariel, Israel
| | - Yuri Feldman
- Applied Physics Department and the Center for Electromagnetic Research and Characterization, The Hebrew University of Jerusalem, 91904, Jerusalem, Israel.
| |
Collapse
|
11
|
Acciaroli G, Zanon M, Facchinetti A, Caduff A, Sparacino G. Retrospective Continuous-Time Blood Glucose Estimation in Free Living Conditions with a Non-Invasive Multisensor Device. SENSORS 2019; 19:s19173677. [PMID: 31450547 PMCID: PMC6749353 DOI: 10.3390/s19173677] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 08/01/2019] [Accepted: 08/22/2019] [Indexed: 01/09/2023]
Abstract
Even if still at an early stage of development, non-invasive continuous glucose monitoring (NI-CGM) sensors represent a promising technology for optimizing diabetes therapy. Recent studies showed that the Multisensor provides useful information about glucose dynamics with a mean absolute relative difference (MARD) of 35.4% in a fully prospective setting. Here we propose a method that, exploiting the same Multisensor measurements, but in a retrospective setting, achieves a much better accuracy. Data acquired by the Multisensor during a long-term study are retrospectively processed following a two-step procedure. First, the raw data are transformed to a blood glucose (BG) estimate by a multiple linear regression model. Then, an enhancing module is applied in cascade to the regression model to improve the accuracy of the glucose estimation by retrofitting available BG references through a time-varying linear model. MARD between the retrospectively reconstructed BG time-series and reference values is 20%. Here, 94% of values fall in zone A or B of the Clarke Error Grid. The proposed algorithm achieved a level of accuracy that could make this device a potential complementary tool for diabetes management and also for guiding prediabetic or nondiabetic users through life-style changes.
Collapse
Affiliation(s)
- Giada Acciaroli
- Department of Information Engineering, University of Padova, 35131 Padova, Italy
| | | | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, 35131 Padova, Italy
| | | | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, 35131 Padova, Italy.
| |
Collapse
|
12
|
Yilmaz T, Foster R, Hao Y. Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels. Diagnostics (Basel) 2019; 9:diagnostics9010006. [PMID: 30626128 PMCID: PMC6468903 DOI: 10.3390/diagnostics9010006] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 12/13/2018] [Accepted: 12/21/2018] [Indexed: 12/13/2022] Open
Abstract
This paper reviews non-invasive blood glucose measurements via dielectric spectroscopy at microwave frequencies presented in the literature. The intent is to clarify the key challenges that must be overcome if this approach is to work, to suggest some possible ways towards addressing these challenges and to contribute towards prevention of unnecessary ‘reinvention of the wheel’.
Collapse
Affiliation(s)
- Tuba Yilmaz
- Department of Electronics and Communication Engineering, Istanbul Technical University, 34469 Istanbul, Turkey.
| | - Robert Foster
- Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Birmingham B15 2TT, UK.
| | - Yang Hao
- School of Electronic Engineering and Computer Science, Queen Mary University of London, London E1 4NS, UK.
| |
Collapse
|
13
|
Delbeck S, Vahlsing T, Leonhardt S, Steiner G, Heise HM. Non-invasive monitoring of blood glucose using optical methods for skin spectroscopy-opportunities and recent advances. Anal Bioanal Chem 2018; 411:63-77. [PMID: 30283998 DOI: 10.1007/s00216-018-1395-x] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 09/17/2018] [Accepted: 09/20/2018] [Indexed: 12/29/2022]
Abstract
Diabetes mellitus is a widespread disease with greatly rising patient numbers expected in the future, not only for industrialized countries but also for regions in the developing world. There is a need for efficient therapy, which can be via self-monitoring of blood glucose levels to provide tight glycemic control for reducing the risks of severe health complications. Advancements in diabetes technology can nowadays offer different sensor approaches, even for continuous blood glucose monitoring. Non-invasive blood glucose assays have been promised for many years and various vibrational spectroscopy-based methods of the skin are candidates for achieving this goal. Due to the small spectral signatures of the glucose hidden among a largely variable background, the largest signal-to-noise ratios and multivariate calibration are essential to provide the method applicability for self-monitoring of blood glucose. Besides multiparameter approaches, recently presented devices based on photoplethysmography with wavelengths in the visible and near-infrared range are evaluated for their potential of providing reliable blood glucose concentration predictions. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Sven Delbeck
- Interdisciplinary Center for Life Sciences, South-Westphalia University of Applied Sciences, Frauenstuhlweg 31, 58644, Iserlohn, Germany
| | - Thorsten Vahlsing
- Bundesanstalt für Materialforschung und -prüfung (BAM), Acoustic and Electromagnetic Methods, Unter den Eichen 87, 12205, Berlin, Germany.,Chair for Medical Information Technology, Helmholtz Institute of Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Steffen Leonhardt
- Chair for Medical Information Technology, Helmholtz Institute of Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Gerald Steiner
- Faculty of Medicine Carl Gustav Carus, Clinical Sensoring and Monitoring, Technical University of Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - H Michael Heise
- Interdisciplinary Center for Life Sciences, South-Westphalia University of Applied Sciences, Frauenstuhlweg 31, 58644, Iserlohn, Germany.
| |
Collapse
|