1
|
Salama AA, Abozied OA, Anderson JH, Miranda WR, Connolly HM, Jain C, Cabalka A, Egbe AC. Cardiac Reverse Remodeling and Changes in Heart Failure Indices After Transcatheter Tricuspid Valve Replacement in Adults With Congenital Heart Disease. Circ Cardiovasc Interv 2024; 17:e013334. [PMID: 37942627 PMCID: PMC10841471 DOI: 10.1161/circinterventions.123.013334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 09/11/2023] [Indexed: 11/10/2023]
Abstract
BACKGROUND There are limited data about changes in cardiac function (cardiac reverse remodeling) and heart failure indices after transcatheter tricuspid valve-in-valve replacement (TT-VIVR). The purpose of this study was to evaluate cardiac reverse remodeling and temporal changes in heart failure indices after TT-VIVR in adults with congenital heart disease. METHODS Retrospective cohort study of adults with congenital heart disease that underwent TT-VIVR and had >6 months of follow-up (January 1, 2011, to April 30, 2023). Echocardiographic indices of cardiac remodeling and heart failure indices (New York Heart Association class, NT-proBNP (N-terminal pro-brain natriuretic peptide), glomerular filtration rate, and model for end-stage liver disease excluding international normalized ratio score) were assessed preintervention and at 1-, 3-, and 5-year postintervention. RESULTS Of 39 patients (age 39 [32-46] years), 14 (36%) and 25 (64%) received Melody valve and Sapien valve prosthesis, respectively. At 1-year post-TT-VIVR, there was a temporal improvement in right atrial reservoir strain (17±8% versus 22±8%, P<0.001), right atrial volume (81 [59-108] versus 63 [48-82] mL/m2, P<0.001), right atrial pressure (12±4% versus 6±4%, P<0.001), and right ventricular global longitudinal strain (-15±7% versus -20±7%, P<0.001). Similarly, there was a temporal improvement in NT-proBNP, glomerular filtration rate, model for end-stage liver disease excluding international normalized ratio score, and New York Heart Association class. The temporal improvements in heart failure indices and valve function were maintained at 3- and 5-year post-TT-VIVR. CONCLUSIONS Considering the significant mortality risk associated with reoperations for tricuspid valve replacement, these data suggest favorable outcomes after TT-VIVR, and support TT-VIVR as a viable alternative to surgical tricuspid valve replacement, especially in high-risk patients.
Collapse
Affiliation(s)
- Abdalla A Salama
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
- Department of Cardiovascular Diseases, Suez Canal University, Ismailia, Egypt (A.A.S.)
| | - Omar A Abozied
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| | - Jason H Anderson
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| | - William R Miranda
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| | - Heidi M Connolly
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| | - Charles Jain
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| | - Allison Cabalka
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| | - Alexander C Egbe
- Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN (A.A.S., O.A.A., J.H.A., W.R.M., H.M.C., C.J., A.C., A.C.E.)
| |
Collapse
|
2
|
Wei W, Ning L, Xiaoping N, Zhiyun X, Bailing L, Chengliang C, Fan Y, Guangwei Z, Yifan B, Lin H, Fan Q, Fanglin L. Hemodynamics of transcatheter tricuspid valve replacement with Lux-Valve. Front Cardiovasc Med 2022; 9:1007888. [PMID: 36312292 PMCID: PMC9614150 DOI: 10.3389/fcvm.2022.1007888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 09/29/2022] [Indexed: 11/24/2022] Open
Abstract
Objective Transcatheter tricuspid valve intervention (TTVI) has emerged as an alternative treatment option for high-risk and inoperable patients with symptomatic tricuspid regurgitation (TR). However, scarce data in hemodynamic profiles were available on TTVI. In this paper, we attempt to report the hemodynamic profiles of LuX-Valve. Methods 30 patients from July 2020 to July 2021 were enrolled in this study. The patient was diagnosed with severe symptomatic TR. The clinical, invasive hemodynamic, and echocardiographic data were collected. Results The surgical success rate was 100%. The cardiac index and stroke volume increased sharply from 2.42(2.27, 2.85) and 47.8(43.6, 62.0) to 3.04 ± 0.63 and 57.2 ± 14.7, respectively. With the elimination of TR and the increase of forward blood flow of the tricuspid valve, the extravascular lung water [798.0 (673.0, 1147.0) vs. 850.3 ± 376.1, P < 0.01] increased subsequently. The peak right atrium pressure decreased after Lux-Valve implantation (21.0 ± 6.4 vs. 19.4 ± 6.5, P < 0.05). On the contrary, the nadir right atrium pressure increased [10.0(8.0, 15.0) vs. 12.0(10.0, 17.0), P < 0.01]. Notably, the right atrium pressure difference dropped sharply from 9.0(5.0, 13.0) to 5.0(4.0, 8.0) after Lux-Valve implantation. There was no significant change in the pulmonary artery pressure. The right atrium volume decreased from 128(83, 188) to 91(67, 167) mL at 1 month and 107(66,157) mL at 6 months. With the remolding of the right heart chamber, the tricuspid annulus diameter shrank significantly from 42.5 ± 5.6 to 36.6 ± 6.3 mm at 1 month and 36.0 (33.0, 38.0) at 6 months. Conclusion Invasive right atrium pressure may act as a potential candidate for TR evaluation and procedural guidance. Elimination of TR by LuX-Valve implantation improves the cardiac output and right atrium pressure and has no significant effect on the pulmonary artery pressure even with the increment of forward blood flow, suggesting the hemodynamic superiority of transcatheter tricuspid valve replacement but needs further study.
Collapse
Affiliation(s)
- Wang Wei
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Li Ning
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China,Department of Cardiothoracic Surgery, Naval Medical Center of PLA, Shanghai, China
| | - Ning Xiaoping
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Xu Zhiyun
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Li Bailing
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Cai Chengliang
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Yang Fan
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Zhou Guangwei
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Bai Yifan
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China
| | - Han Lin
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China,Han Lin
| | - Qiao Fan
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China,Qiao Fan
| | - Lu Fanglin
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Military Medical University, Shanghai, China,*Correspondence: Lu Fanglin
| |
Collapse
|
3
|
Seckeler MD, Bliss A, Rischard F, Klewer SE. Early bioprosthetic tricuspid valve stenosis due to size mismatch in Ebstein anomaly-Successful transcatheter treatment. J Card Surg 2020; 35:3138-3140. [PMID: 32789873 DOI: 10.1111/jocs.14945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Patients with congenital heart disease are surviving well into adulthood thanks to advances in medical and clinical care. We present a patient with Ebstein anomaly who underwent surgical tricuspid valve replacement and suffered early valve stenosis due to her unique anatomy. This case highlights the importance of the "unnatural" anatomy that can be encounter in this challenging patient population.
Collapse
Affiliation(s)
- Michael D Seckeler
- Department of Pediatrics (Cardiology), University of Arizona, Tucson, Arizona
| | - Alison Bliss
- Department of Pediatrics (Cardiology), University of Arizona, Tucson, Arizona
| | - Franz Rischard
- Division of Pulmonary and Critical Care, Department of Medicine, University of Arizona, Tucson, Arizona
| | - Scott E Klewer
- Department of Pediatrics (Cardiology), University of Arizona, Tucson, Arizona
| |
Collapse
|