1
|
Oberhoffner T, Mlynski R, Schraven S, Brademann G, Dierker A, Spitzer P, Hey M. Effects of Intraoperative Cochlear Implant Electrode Conditioning on Impedances and Electrically Evoked Compound Action Potentials. IEEE Trans Biomed Eng 2024; 71:650-659. [PMID: 37682654 DOI: 10.1109/tbme.2023.3313198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
OBJECTIVE The current study investigates whether, during a Cochlear Implant (CI) surgery, conditioning (i.e. applying short bursts of electrical stimulation) within a saline solution can have positive effects on subsequent intra-operative measurements. We hypothesize that, based on previous research, the impedance values will be reduced, and that the reproducibility of Electrically Evoked Compound Action Potentials (ECAPs) is improved as a result of conditioning. METHODS We conditioned half of the electrode contacts, within a saline solution, before CI insertion, using 23 MED-EL implants. Impedance was measured for both the conditioned and non-conditioned groups at five time points. Repeated ECAP recordings were measured and compared between the conditioned and non-conditioned groups. RESULTS Impedance of the electrode contacts were reduced by 31% after conditioning in saline solution; however, there were no clinically relevant differences after the implantation of the electrode array. The hypothesis that measurement reproducibility would be increased after conditioning could not be confirmed with our data. Within the saline solution, we observed that 44% of the electrode contacts were covered with air bubbles, which most disappeared after implantation. However, these air bubbles limited the effectiveness of the conditioning within the saline solution. Lastly, the effect of conditioning on the reference electrode stimulation was approximately 16% of the total reduction in impedance. CONCLUSION Our data does not suggest that intraoperative conditioning is clinically required for cochlear implantation with MED-EL implants. Additionally, an in-vivo ECAP recording can be considered as a method of conditioning the electrode contacts. SIGNIFICANCE We confirm that the common clinical practice does not need to be changed.
Collapse
|
2
|
Dennison SR, Thakkar T, Kan A, Litovsky RY. Lateralization of binaural envelope cues measured with a mobile cochlear-implant research processora). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:3543-3558. [PMID: 37390320 PMCID: PMC10314808 DOI: 10.1121/10.0019879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 06/09/2023] [Accepted: 06/09/2023] [Indexed: 07/02/2023]
Abstract
Bilateral cochlear implant (BICI) listeners do not have full access to the binaural cues that normal hearing (NH) listeners use for spatial hearing tasks such as localization. When using their unsynchronized everyday processors, BICI listeners demonstrate sensitivity to interaural level differences (ILDs) in the envelopes of sounds, but interaural time differences (ITDs) are less reliably available. It is unclear how BICI listeners use combinations of ILDs and envelope ITDs, and how much each cue contributes to perceived sound location. The CCi-MOBILE is a bilaterally synchronized research processor with the untested potential to provide spatial cues to BICI listeners. In the present study, the CCi-MOBILE was used to measure the ability of BICI listeners to perceive lateralized sound sources when single pairs of electrodes were presented amplitude-modulated stimuli with combinations of ILDs and envelope ITDs. Young NH listeners were also tested using amplitude-modulated high-frequency tones. A cue weighting analysis with six BICI and ten NH listeners revealed that ILDs contributed more than envelope ITDs to lateralization for both groups. Moreover, envelope ITDs contributed to lateralization for NH listeners but had negligible contribution for BICI listeners. These results suggest that the CCi-MOBILE is suitable for binaural testing and developing bilateral processing strategies.
Collapse
Affiliation(s)
| | - Tanvi Thakkar
- University of Wisconsin-La Crosse, La Crosse, Wisconsin 54601, USA
| | - Alan Kan
- Macquarie University, Macquarie Park, New South Wales, Australia
| | - Ruth Y Litovsky
- University of Wisconsin-Madison, Madison, Wisconsin 53711, USA
| |
Collapse
|
3
|
Ghosh R, Hansen JHL. Bilateral Cochlear Implant Processing of Coding Strategies With CCi-MOBILE, an Open-Source Research Platform. IEEE/ACM TRANSACTIONS ON AUDIO, SPEECH, AND LANGUAGE PROCESSING 2023; 31:1839-1850. [PMID: 38046574 PMCID: PMC10691824 DOI: 10.1109/taslp.2023.3267608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
While speech understanding for cochlear implant (CI) users in quiet is relatively effective, listeners experience difficulty in identification of speaker and sound location. To assist for better residual hearing abilities and speech intelligibility support, bilateral and bimodal forms of assisted hearing is becoming popular among CI users. Effective bilateral processing calls for testing precise algorithm synchronization and fitting between both left and right ear channels in order to capture interaural time and level difference cues (ITD and ILDs). This work demonstrates bilateral implant algorithm processing using a custom-made CI research platform - CCi-MOBILE, which is capable of capturing precise source localization information and supports researchers in testing bilateral CI processing in real-time naturalistic environments. Simulation-based, objective, and subjective testing has been performed to validate the accuracy of the platform. The subjective test results produced an RMS error of ±8.66° for source localization, which is comparable to the performance of commercial CI processors.
Collapse
Affiliation(s)
- Ria Ghosh
- Center for Robust Speech Systems, CILab - Cochlear Implant Processing Lab, Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX 75080 USA
| | - John H L Hansen
- Center for Robust Speech Systems, CILab - Cochlear Implant Processing Lab, Department of Electrical and Computer Engineering, Erik Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, TX 75080 USA, and also with the School of Behavioral and Brain Sciences, University of Texas at Dallas, Richardson, TX 75080 USA
| |
Collapse
|
4
|
Thakkar T, Kan A, Litovsky RY. Lateralization of interaural time differences with mixed rates of stimulation in bilateral cochlear implant listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:1912. [PMID: 37002065 PMCID: PMC10036141 DOI: 10.1121/10.0017603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 02/23/2023] [Accepted: 02/25/2023] [Indexed: 05/18/2023]
Abstract
While listeners with bilateral cochlear implants (BiCIs) are able to access information in both ears, they still struggle to perform well on spatial hearing tasks when compared to normal hearing listeners. This performance gap could be attributed to the high stimulation rates used for speech representation in clinical processors. Prior work has shown that spatial cues, such as interaural time differences (ITDs), are best conveyed at low rates. Further, BiCI listeners are sensitive to ITDs with a mixture of high and low rates. However, it remains unclear whether mixed-rate stimuli are perceived as unitary percepts and spatially mapped to intracranial locations. Here, electrical pulse trains were presented on five, interaurally pitch-matched electrode pairs using research processors, at either uniformly high rates, low rates, or mixed rates. Eight post-lingually deafened adults were tested on perceived intracranial lateralization of ITDs ranging from 50 to 1600 μs. Extent of lateralization depended on the location of low-rate stimulation along the electrode array: greatest in the low- and mixed-rate configurations, and smallest in the high-rate configuration. All but one listener perceived a unitary auditory object. These findings suggest that a mixed-rate processing strategy can result in good lateralization and convey a unitary auditory object with ITDs.
Collapse
Affiliation(s)
- Tanvi Thakkar
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Alan Kan
- School of Engineering, Macquarie University, New South Wales 2109, Australia
| | - Ruth Y Litovsky
- Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| |
Collapse
|
5
|
Anderson SR, Kan A, Litovsky RY. Asymmetric temporal envelope sensitivity: Within- and across-ear envelope comparisons in listeners with bilateral cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:3294. [PMID: 36586876 PMCID: PMC9731674 DOI: 10.1121/10.0016365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 11/14/2022] [Accepted: 11/16/2022] [Indexed: 06/17/2023]
Abstract
For listeners with bilateral cochlear implants (BiCIs), patient-specific differences in the interface between cochlear implant (CI) electrodes and the auditory nerve can lead to degraded temporal envelope information, compromising the ability to distinguish between targets of interest and background noise. It is unclear how comparisons of degraded temporal envelope information across spectral channels (i.e., electrodes) affect the ability to detect differences in the temporal envelope, specifically amplitude modulation (AM) rate. In this study, two pulse trains were presented simultaneously via pairs of electrodes in different places of stimulation, within and/or across ears, with identical or differing AM rates. Results from 11 adults with BiCIs indicated that sensitivity to differences in AM rate was greatest when stimuli were paired between different places of stimulation in the same ear. Sensitivity from pairs of electrodes was predicted by the poorer electrode in the pair or the difference in fidelity between both electrodes in the pair. These findings suggest that electrodes yielding poorer temporal fidelity act as a bottleneck to comparisons of temporal information across frequency and ears, limiting access to the cues used to segregate sounds, which has important implications for device programming and optimizing patient outcomes with CIs.
Collapse
Affiliation(s)
- Sean R Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Alan Kan
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | - Ruth Y Litovsky
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| |
Collapse
|
6
|
Cleary M, Bernstein JGW, Stakhovskaya OA, Noble J, Kolberg E, Jensen KK, Hoa M, Kim HJ, Goupell MJ. The Relationship Between Interaural Insertion-Depth Differences, Scalar Location, and Interaural Time-Difference Processing in Adult Bilateral Cochlear-Implant Listeners. Trends Hear 2022; 26:23312165221129165. [PMID: 36379607 PMCID: PMC9669699 DOI: 10.1177/23312165221129165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Sensitivity to interaural time differences (ITDs) in acoustic hearing involves comparison of interaurally frequency-matched inputs. Bilateral cochlear-implant arrays are, however, only approximately aligned in angular insertion depth and scalar location across the cochleae. Interaural place-of-stimulation mismatch therefore has the potential to impact binaural perception. ITD left-right discrimination thresholds were examined in 23 postlingually-deafened adult bilateral cochlear-implant listeners, using low-rate constant-amplitude pulse trains presented via direct stimulation to single electrodes in each ear. Angular insertion depth and scalar location measured from computed-tomography (CT) scans were used to quantify interaural mismatch, and their association with binaural performance was assessed. Number-matched electrodes displayed a median interaural insertion-depth mismatch of 18° and generally yielded best or near-best ITD discrimination thresholds. Two listeners whose discrimination thresholds did not show this pattern were confirmed via CT to have atypical array placement. Listeners with more number-matched electrode pairs located in the scala tympani displayed better thresholds than listeners with fewer such pairs. ITD tuning curves as a function of interaural electrode separation were broad; bandwidths at twice the threshold minimum averaged 10.5 electrodes (equivalent to 5.9 mm for a Cochlear-brand pre-curved array). Larger angular insertion-depth differences were associated with wider bandwidths. Wide ITD tuning curve bandwidths appear to be a product of both monopolar stimulation and angular insertion-depth mismatch. Cases of good ITD sensitivity with very wide bandwidths suggest that precise matching of insertion depth is not critical for discrimination thresholds. Further prioritizing scala tympani location at implantation should, however, benefit ITD sensitivity.
Collapse
Affiliation(s)
- Miranda Cleary
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Joshua G. W. Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical
Center, Bethesda, MD, USA
| | - Olga A. Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Jack Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA,Department of Hearing and Speech Sciences, Vanderbilt University
Medical Center, Nashville, TN, USA,Department of Otolaryngology, Vanderbilt University Medical Center,
Nashville, TN, USA
| | - Elizabeth Kolberg
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Kenneth K. Jensen
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical
Center, Bethesda, MD, USA
| | - Michael Hoa
- Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical
Center, Washington, DC, USA
| | - Hung Jeffrey Kim
- Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical
Center, Washington, DC, USA
| | - Matthew J. Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA,Matthew J. Goupell, Department of Hearing
and Speech Sciences, University of Maryland, College Park, MD 20742, USA.
| |
Collapse
|
7
|
Recording EEG in Cochlear Implant Users: Guidelines for Experimental Design and Data Analysis for Optimizing Signal Quality and Minimizing Artifacts. J Neurosci Methods 2022; 375:109592. [PMID: 35367234 DOI: 10.1016/j.jneumeth.2022.109592] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 03/26/2022] [Accepted: 03/27/2022] [Indexed: 11/22/2022]
Abstract
Cochlear implants (CI) are neural prostheses that can restore hearing in individuals with severe to profound hearing loss. Although CIs significantly improve quality of life, clinical outcomes are still highly variable. An important part of this variability is explained by the brain reorganization following cochlear implantation. Therefore, clinicians and researchers are seeking objective measurements to investigate post-implantation brain plasticity. Electroencephalography (EEG) is a promising technique because it is objective, non-invasive, and implant-compatible, but is nonetheless susceptible to massive artifacts generated by the prosthesis's electrical activity. CI artifacts can blur and distort brain responses; thus, it is crucial to develop reliable techniques to remove them from EEG recordings. Despite numerous artifact removal techniques used in previous studies, there is a paucity of documentation and consensus on the optimal EEG procedures to reduce these artifacts. Herein, and through a comprehensive review process, we provide a guideline for designing an EEG-CI experiment minimizing the effect of the artifact. We provide some technical guidance for recording an accurate neural response from CI users and discuss the current challenges in detecting and removing CI-induced artifacts from a recorded signal. The aim of this paper is also to provide recommendations to better appraise and report EEG-CI findings.
Collapse
|
8
|
Ghosh R, Ali H, Hansen JHL. CCi-MOBILE: A Portable Real Time Speech Processing Platform for Cochlear Implant and Hearing Research. IEEE Trans Biomed Eng 2022; 69:1251-1263. [PMID: 34705633 PMCID: PMC8918373 DOI: 10.1109/tbme.2021.3123241] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Experimental hardware-research interfaces form a crucial role during developmental stages of any medical, signal-monitoring system as it allows researchers to test and optimize output results before perfecting the design for the actual FDA approved medical device and large-scale production. These testing platforms, intake raw signals through which performance of novel algorithms can be analyzed and modified to generate the desired data points for an optimized output, allowing the advancement of the medical device. With cochlear implants (CIs) and hearing aids (HAs) becoming a more common solution for varying degrees of hearing impairment, having modern signal processing strategies tested for such speech sensitive systems is a necessity. But the rigid design requirements of commercial CI and HA processors make it difficult to explore novel algorithms for research investigations and conducting longitudinal studies. This study presents the design, development, clinical evaluation, and applications of CCi-MOBILE, a computationally powerful signal processing testing platform built for researchers in the hearing-impaired field. The custom-made, portable research platform allows researchers to design and perform complex speech processing algorithm assessment offline and in real-time. It can be operated through user-friendly, open-source software and is compatible with implants manufactured by Cochlear Corporation. The FPGA design and hardware processing pipeline for CI stimulation is discussed followed by results from an acute study with implant users' speech intelligibility in quiet and noisy conditions. The results show a consistent level of performance compared with CI users' clinical processor, thus confirming the viability of the platform in chronic CI based studies.
Collapse
|
9
|
Navntoft CA, Landsberger DM, Barkat TR, Marozeau J. The Perception of Ramped Pulse Shapes in Cochlear Implant Users. Trends Hear 2021; 25:23312165211061116. [PMID: 34935552 PMCID: PMC8724057 DOI: 10.1177/23312165211061116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The electric stimulation provided by current cochlear implants (CI) is not power
efficient. One underlying problem is the poor efficiency by which information
from electric pulses is transformed into auditory nerve responses. A novel
stimulation paradigm using ramped pulse shapes has recently been proposed to
remedy this inefficiency. The primary motivation is a better biophysical fit to
spiral ganglion neurons with ramped pulses compared to the rectangular pulses
used in most contemporary CIs. Here, we tested the hypotheses that ramped pulses
provide more efficient stimulation compared to rectangular pulses and that a
rising ramp is more efficient than a declining ramp. Rectangular, rising ramped
and declining ramped pulse shapes were compared in terms of charge efficiency
and discriminability, and threshold variability in seven CI listeners. The tasks
included single-channel threshold detection, loudness-balancing, discrimination
of pulse shapes, and threshold measurement across the electrode array. Results
showed that reduced charge, but increased peak current amplitudes, was required
at threshold and most comfortable levels with ramped pulses relative to
rectangular pulses. Furthermore, only one subject could reliably discriminate
between equally-loud ramped and rectangular pulses, suggesting variations in
neural activation patterns between pulse shapes in that participant. No
significant difference was found between rising and declining ramped pulses
across all tests. In summary, the present findings show some benefits of charge
efficiency with ramped pulses relative to rectangular pulses, that the direction
of a ramped slope is of less importance, and that most participants could not
perceive a difference between pulse shapes.
Collapse
Affiliation(s)
- Charlotte Amalie Navntoft
- Hearing Systems Group, Department of Health Technology, 5205Technical University of Denmark, Kgs. Lyngby, Denmark.,Brain and Sound Lab, Department of Biomedicine, 27209Basel University, Basel, Switzerland
| | - David M Landsberger
- Department of Otolaryngology, 12296New York University School of Medicine, New York, USA
| | - Tania Rinaldi Barkat
- Brain and Sound Lab, Department of Biomedicine, 27209Basel University, Basel, Switzerland
| | - Jeremy Marozeau
- Hearing Systems Group, Department of Health Technology, 5205Technical University of Denmark, Kgs. Lyngby, Denmark
| |
Collapse
|
10
|
Gärtner L, Spitzer P, Lauss K, Takanen M, Lenarz T, Hoth S. Optimized SNR-based ECAP threshold determination is comparable to the judgement of human evaluators. PLoS One 2021; 16:e0259347. [PMID: 34723991 PMCID: PMC8559956 DOI: 10.1371/journal.pone.0259347] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 10/18/2021] [Indexed: 12/02/2022] Open
Abstract
In cochlear implant (CI) users, measurements of electrically evoked compound action potentials (ECAPs) prove the functionality of the neuron-electrode interface. Objective measures, e.g., the ECAP threshold, may serve as a basis for the clinical adjustment of the device for the optimal benefit of the CI user. As for many neural responses, the threshold determination often is based on the subjective assessment of the clinical specialist, whose decision-making process could be aided by autonomous computational algorithms. To that end, we extended the signal-to-noise ratio (SNR) approach for ECAP threshold determination to be applicable for FineGrain (FG) ECAP responses. The new approach takes advantage of two features: the FG stimulation paradigm with its enhanced resolution of recordings, and SNR-based ECAP threshold determination, which allows defining thresholds independently of morphology and with comparably low computational power. Pearson's correlation coefficient r between the ECAP threshold determined by five experienced evaluators and the threshold determined with the FG-SNR algorithm was in the range of r = 0.78-0.93. Between evaluators, r was in a comparable range of 0.84-0.93. A subset of the parameters of the algorithm was varied to identify the parameters with the highest potential to improve the FG-SNR formalism in the future. The two steps with the strongest influence on the agreement between the threshold estimate of the evaluators and the algorithm were the removal of undesired frequency components (denoising of the response traces) and the exact determination of the two time windows (signal and noise and noise only)."The parameters were linked to the properties of an ECAP response, indicating how to adjust the algorithm for the automatic detection of other neurophysiological responses.
Collapse
Affiliation(s)
- Lutz Gärtner
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Philipp Spitzer
- Research and Development, MED-EL Medical Electronics, Innsbruck, Austria
| | - Kathrin Lauss
- Research and Development, MED-EL Medical Electronics, Innsbruck, Austria
| | - Marko Takanen
- Research and Development, MED-EL Medical Electronics, Innsbruck, Austria
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Sebastian Hoth
- Funktionsbereich Audiologie, Universitäts-HNO-Klinik, Heidelberg, Germany
| |
Collapse
|
11
|
Johnson KC, Xie Z, Shader MJ, Mayo PG, Goupell MJ. Effect of Chronological Age on Pulse Rate Discrimination in Adult Cochlear-Implant Users. Trends Hear 2021; 25:23312165211007367. [PMID: 34028313 PMCID: PMC8150454 DOI: 10.1177/23312165211007367] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Cochlear-implant (CI) users rely heavily on temporal envelope cues to understand speech. Temporal processing abilities may decline with advancing age in adult CI users. This study investigated the effect of age on the ability to discriminate changes in pulse rate. Twenty CI users aged 23 to 80 years participated in a rate discrimination task. They attempted to discriminate a 35% rate increase from baseline rates of 100, 200, 300, 400, or 500 pulses per second. The stimuli were electrical pulse trains delivered to a single electrode via direct stimulation to an apical (Electrode 20), a middle (Electrode 12), or a basal location (Electrode 4). Electrically evoked compound action potential amplitude growth functions were recorded at each of those electrodes as an estimate of peripheral neural survival. Results showed that temporal pulse rate discrimination performance declined with advancing age at higher stimulation rates (e.g., 500 pulses per second) when compared with lower rates. The age-related changes in temporal pulse rate discrimination at higher stimulation rates persisted after statistical analysis to account for the estimated peripheral contributions from electrically evoked compound action potential amplitude growth functions. These results indicate the potential contributions of central factors to the limitations in temporal pulse rate discrimination ability associated with aging in CI users.
Collapse
Affiliation(s)
- Kelly C Johnson
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States
| | - Zilong Xie
- Department of Hearing and Speech, University of Kansas Medical Center, Kansas City, United States
| | - Maureen J Shader
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States.,Bionics Institute, Melbourne, Australia.,Department of Medical Bionics, The University of Melbourne, Melbourne, Australia
| | - Paul G Mayo
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States
| |
Collapse
|
12
|
Shekar RCMC, Hansen JHL. An evaluation framework for research platforms to advance cochlear implant/hearing aid technology: A case study with CCi-MOBILE. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:229. [PMID: 33514127 PMCID: PMC7803384 DOI: 10.1121/10.0002989] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 12/06/2020] [Accepted: 12/09/2020] [Indexed: 06/12/2023]
Abstract
Cochlear implants (CIs) and hearing aids (HAs) are advanced assistive hearing devices that perform sound processing to achieve acoustic to acoustic/electrical stimulation, thus enabling the prospects for hearing restoration and rehabilitation. Since commercial CIs/HAs are typically constrained by manufacturer design/production constraints, it is necessary for researchers to use research platforms (RPs) to advance algorithms and conduct investigational studies with CI/HA subjects. While previous CI/HA research platforms exist, no study has explored establishing a formal evaluation protocol for the operational safety and reliability of RPs. This study proposes a two-phase analysis and evaluation paradigm for RPs. In the acoustic phase 1 step, a signal processing acoustic space is explored in order to present a sampled set of audio input content to explore the safety of the resulting output electric/acoustic stimulation. In the parameter phase 2 step, the configurable space for realizable electrical stimulation pulses is determined, and overall stimulation reliability and safety are evaluated. The proposed protocol is applied and demonstrated using Costakis Cochlear Implant Mobile. Assessment protocol observations, results, and additional best practices for subsampling of the acoustic and parameter test spaces are discussed. The proposed analysis-evaluation protocol establishes a viable framework for assessing RP operational safety and reliability. Guidelines for adapting the proposed protocol to address variability in RP configuration due to experimental factors such as custom algorithms, stimulation techniques, and/or individualization are also considered.
Collapse
Affiliation(s)
- Ram C M C Shekar
- Cochlear Implant Processing Laboratory, Center for Robust Speech Systems (CRSS-CILab), Department of Electrical and Computer Engineering, Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, Texas 75080, USA
| | - John H L Hansen
- Cochlear Implant Processing Laboratory, Center for Robust Speech Systems (CRSS-CILab), Department of Electrical and Computer Engineering, Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, Texas 75080, USA
| |
Collapse
|
13
|
Shader MJ, Gordon-Salant S, Goupell MJ. Impact of Aging and the Electrode-to-Neural Interface on Temporal Processing Ability in Cochlear-Implant Users: Amplitude-Modulation Detection Thresholds. Trends Hear 2020; 24:2331216520936160. [PMID: 32833587 PMCID: PMC7448135 DOI: 10.1177/2331216520936160] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Although cochlear implants (CIs) are a viable treatment option for severe hearing loss in adults of any age, older adults may be at a disadvantage compared with younger adults. CIs deliver signals that contain limited spectral information, requiring CI users to attend to the temporal information within the signal to recognize speech. Older adults are susceptible to acquiring auditory temporal processing deficits, presenting a potential age-related limitation for recognizing speech signals delivered by CIs. The goal of this study was to measure auditory temporal processing ability via amplitude-modulation (AM) detection as a function of age in CI users. The contribution of the electrode-to-neural interface, in addition to age, was estimated using electrically evoked compound action potential (ECAP) amplitude growth functions. Within each participant, two electrodes were selected: one with the steepest ECAP slope and one with the shallowest ECAP slope, in order to represent electrodes with varied estimates of the electrode-to-neural interface. Single-electrode AM detection thresholds were measured using direct stimulation at these two electrode locations. Results revealed that AM detection ability significantly declined as a function of chronological age. ECAP slope did not significantly impact AM detection, but ECAP slope decreased (became shallower) with increasing age, suggesting that factors influencing the electrode-to-neural interface change with age. Results demonstrated a significant negative impact of chronological age on auditory temporal processing. The locus of the age-related limitation (peripheral vs. central origin), however, is difficult to evaluate because the peripheral influence (ECAPs) was correlated with the central factor (age).
Collapse
Affiliation(s)
- Maureen J Shader
- Department of Hearing and Speech Sciences, University of Maryland
| | | | | |
Collapse
|
14
|
Thakkar T, Anderson SR, Kan A, Litovsky RY. Evaluating the Impact of Age, Acoustic Exposure, and Electrical Stimulation on Binaural Sensitivity in Adult Bilateral Cochlear Implant Patients. Brain Sci 2020; 10:E406. [PMID: 32604860 PMCID: PMC7348899 DOI: 10.3390/brainsci10060406] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 06/15/2020] [Accepted: 06/19/2020] [Indexed: 01/10/2023] Open
Abstract
Deafness in both ears is highly disruptive to communication in everyday listening situations. Many individuals with profound deafness receive bilateral cochlear implants (CIs) to gain access to spatial cues used in localization and speech understanding in noise. However, the benefit of bilateral CIs, in particular sensitivity to interaural time and level differences (ITD and ILDs), varies among patients. We measured binaural sensitivity in 46 adult bilateral CI patients to explore the relationship between binaural sensitivity and three classes of patient-related factors: age, acoustic exposure, and electric hearing experience. Results show that ILD sensitivity increased with shorter years of acoustic exposure, younger age at testing, or an interaction between these factors, moderated by the duration of bilateral hearing impairment. ITD sensitivity was impacted by a moderating effect between years of bilateral hearing impairment and CI experience. When age at onset of deafness was treated as two categories (<18 vs. >18 years of age), there was no clear effect for ILD sensitivity, but some differences were observed for ITD sensitivity. Our findings imply that maximal binaural sensitivity is obtained by listeners with a shorter bilateral hearing impairment, a longer duration of CI experience, and potentially a younger age at testing. 198/200.
Collapse
Affiliation(s)
- Tanvi Thakkar
- Waisman Center, University of Wisconsin-Madison, Madison, WI 53705, USA; (T.T.); (S.R.A.)
| | - Sean R. Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, WI 53705, USA; (T.T.); (S.R.A.)
| | - Alan Kan
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia;
| | - Ruth Y. Litovsky
- Waisman Center, University of Wisconsin-Madison, Madison, WI 53705, USA; (T.T.); (S.R.A.)
| |
Collapse
|
15
|
Shader MJ, Gordon-Salant S, Goupell MJ. Impact of Aging and the Electrode-to-Neural Interface on Temporal Processing Ability in Cochlear-Implant Users: Gap Detection Thresholds. Trends Hear 2020; 24:2331216520956560. [PMID: 32941111 PMCID: PMC7502859 DOI: 10.1177/2331216520956560] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 08/06/2020] [Accepted: 08/14/2020] [Indexed: 11/17/2022] Open
Abstract
Accurate processing of temporal information is critical to understanding speech through a cochlear implant (CI). This has potential implications for the growing population of CI users who are ≥65 years of age because of age-related auditory temporal processing deficits. The goal of this study was to measure temporal processing ability in a gap detection task in younger, middle-aged, and older CI users and to determine the relative contributions of chronological age and peripheral neural survival to performance. Single-electrode gap detection thresholds (GDTs) were measured using direct stimulation at five electrode locations and three electrical stimulation rates. The relationship between peripheral status (e.g., electrode-to-neural interface) and GDTs was assessed by the slope of the electrically evoked compound action potential (ECAP) amplitude growth function. Results showed that ECAP slope was the strongest subject-level predictor of GDTs. Steeper ECAP slopes, which are partially indicative of better peripheral function, were associated with better GDTs in younger participants. However, ECAP slope significantly interacted with stimulation rate and age, suggesting that ECAP slopes were not predictive of GDTs in middle-aged and older participants at some stimulation rates. ECAP slope was also related to age, with middle-aged and older participants exhibiting relatively shallow slopes and smaller ranges of slopes compared with younger participants. This pattern of ECAP results limited the evaluation of the independent effects of aging per se and peripheral status on temporal processing ability.
Collapse
Affiliation(s)
- Maureen J. Shader
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, United States
| | - Sandra Gordon-Salant
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, United States
| | - Matthew J. Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, United States
| |
Collapse
|
16
|
Anderson SR, Easter K, Goupell MJ. Effects of rate and age in processing interaural time and level differences in normal-hearing and bilateral cochlear-implant listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:3232. [PMID: 31795662 PMCID: PMC6948219 DOI: 10.1121/1.5130384] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 09/27/2019] [Accepted: 10/02/2019] [Indexed: 05/25/2023]
Abstract
Bilateral cochlear implants (BICIs) provide improved sound localization and speech understanding in noise compared to unilateral CIs. However, normal-hearing (NH) listeners demonstrate superior binaural processing abilities compared to BICI listeners. This investigation sought to understand differences between NH and BICI listeners' processing of interaural time differences (ITDs) and interaural level differences (ILDs) as a function of fine-structure and envelope rate using an intracranial lateralization task. The NH listeners were presented band-limited acoustical pulse trains and sinusoidally amplitude-modulated tones using headphones, and the BICI listeners were presented single-electrode electrical pulse trains using direct stimulation. Lateralization range increased as fine-structure rate increased for ILDs in BICI listeners. Lateralization range decreased for rates above 100 Hz for fine-structure ITDs, but decreased for rates lower or higher than 100 Hz for envelope ITDs in both groups. Lateralization ranges for ITDs were smaller for BICI listeners on average. After controlling for age, older listeners showed smaller lateralization ranges and BICI listeners had a more rapid decline for ITD sensitivity at 300 pulses per second. This work suggests that age confounds comparisons between NH and BICI listeners in temporal processing tasks and that some NH-BICI binaural processing differences persist even when age differences are adequately addressed.
Collapse
Affiliation(s)
- Sean R Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Kyle Easter
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| |
Collapse
|
17
|
Kan A, Goupell MJ, Litovsky RY. Effect of channel separation and interaural mismatch on fusion and lateralization in normal-hearing and cochlear-implant listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1448. [PMID: 31472555 PMCID: PMC6713556 DOI: 10.1121/1.5123464] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 08/05/2019] [Accepted: 08/05/2019] [Indexed: 05/29/2023]
Abstract
Bilateral cochlear implantation has provided access to some of the benefits of binaural hearing enjoyed by normal-hearing (NH) listeners. However, a gap in performance still exists between the two populations. Single-channel stimulation studies have shown that interaural place-of-stimulation mismatch (IPM) due to differences in implantation depth leads to decreased binaural fusion and lateralization of interaural time and level differences (ITDs and ILDs, respectively). While single-channel studies are informative, multi-channel stimulation is needed for good speech understanding with cochlear implants (CIs). Some multi-channel studies have shown that channel interaction due to current spread can affect ITD sensitivity. In this work, we studied the effect of IPM and channel spacing, along with their potential interaction, on binaural fusion and ITD/ILD lateralization. Experiments were conducted in adult NH listeners and CI listeners with a history of acoustic hearing. Results showed that IPM reduced the range of lateralization for ITDs but not ILDs. CI listeners were more likely to report a fused percept in the presence of IPM with multi-channel stimulation than NH listeners. However, no effect of channel spacing was found. These results suggest that IPM should be accounted for in clinical mapping practices in order to maximize bilateral CI benefits.
Collapse
Affiliation(s)
- Alan Kan
- Waisman Center, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, Wisconsin 53705, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Ruth Y Litovsky
- Waisman Center, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, Wisconsin 53705, USA
| |
Collapse
|
18
|
Goupell MJ, Fong S, Stakhovskaya O. The effect of envelope modulations on binaural processing. Hear Res 2019; 379:117-127. [PMID: 31154164 DOI: 10.1016/j.heares.2019.05.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 04/29/2019] [Accepted: 05/17/2019] [Indexed: 10/26/2022]
Abstract
An experiment was performed with 10 young normal-hearing listeners that attempted to determine if envelope modulations affected binaural processing in bandlimited pulse trains. Listeners detected an interaurally out-of-phase carrier pulse train in the presence of different amplitude modulations. The peaks of the pulses were constant (called "flat" or F), followed envelope modulations from an interaurally correlated 50-Hz bandwidth noise (called CM), or followed modulations from an interaurally uncorrelated noise (called UM). The pulse rate was varied from 50 to 500 pulses per second (pps) and the center frequency (CF) was 4 or 8 kHz. It was hypothesized that CM would cause no change or an increase in performance compared to F; UM would cause a decrease because of the blurring of the binaural detection cue. There was a small but significant decrease from F to CM (inconsistent with the hypothesis) and a further decrease from CM to UM (consistent with the hypothesis). Critically, there was a significant envelope by rate interaction caused by a decrease from F to CM for the 200-300 pps rates. The data can be explained by a subject-based factor, where some listeners experienced interaural envelope decorrelation when the sound was encoded by the auditory system that reduced performance when the modulations were present. Since the decrease in performance between F and CM conditions was small, it seems that most young normal-hearing listeners have very similar encoding of modulated stimuli across the ears. This type of task, when further optimized, may be able to assess if hearing-impaired populations experience interaural decorrelation from encoding modulated stimuli and therefore could help better understand the limited spatial hearing in populations like cochlear-implant users.
Collapse
Affiliation(s)
- Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, 20742, USA.
| | - Stephen Fong
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, 20742, USA
| | - Olga Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, 20742, USA
| |
Collapse
|
19
|
Stupak N, Padilla M, Morse RP, Landsberger DM. Perceptual Differences Between Low-Frequency Analog and Pulsatile Stimulation as Shown by Single- and Multidimensional Scaling. Trends Hear 2019; 22:2331216518807535. [PMID: 30378468 PMCID: PMC6236864 DOI: 10.1177/2331216518807535] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Cochlear-implant users who have experienced both analog and pulsatile sound
coding strategies often have strong preferences for the sound quality of one
over the other. This suggests that analog and pulsatile stimulation may provide
different information or sound quality to an implant listener. It has been well
documented that many implant listeners both prefer and perform better with
multichannel analog than multichannel pulsatile strategies, although the reasons
for these differences remain unknown. Here, we examine the perceptual
differences between analog and pulsatile stimulation on a single electrode. A
multidimensional scaling task, analyzed across two dimensions, suggested that
pulsatile stimulation was perceived to be considerably different from analog
stimulation. Two associated tasks using single-dimensional scaling showed that
analog stimulation was perceived to be less Clean on average than pulsatile
stimulation and that the perceptual differences were not related to pitch. In a
follow-up experiment, it was determined that the perceptual differences between
analog and pulsatile stimulation were not dependent on the interpulse gap
present in pulsatile stimulation. Although the results suggest that there is a
large perceptual difference between analog and pulsatile stimulation, further
work is needed to determine the nature of these differences.
Collapse
Affiliation(s)
- Natalia Stupak
- 1 Department of Otolaryngology, New York University School of Medicine, NY, USA
| | - Monica Padilla
- 1 Department of Otolaryngology, New York University School of Medicine, NY, USA.,2 USC Tina and Rick Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Robert P Morse
- 3 School of Engineering, University of Warwick, Coventry, UK
| | - David M Landsberger
- 1 Department of Otolaryngology, New York University School of Medicine, NY, USA
| |
Collapse
|
20
|
Interaural Pitch-Discrimination Range Effects for Bilateral and Single-Sided-Deafness Cochlear-Implant Users. J Assoc Res Otolaryngol 2019; 20:187-203. [PMID: 30623318 DOI: 10.1007/s10162-018-00707-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Accepted: 11/26/2018] [Indexed: 10/27/2022] Open
Abstract
By allowing bilateral access to sound, bilateral cochlear implants (BI-CIs) or unilateral CIs for individuals with single-sided deafness (SSD; i.e., normal or near-normal hearing in one ear) can improve sound localization and speech understanding in noise. Spatial hearing in the horizontal plane is primarily conveyed by interaural time and level differences computed from neurons in the superior olivary complex that receive frequency-matched inputs. Because BI-CIs and SSD-CIs do not necessarily convey frequency-matched information, it is critical to understand how to align the inputs to CI users. Previous studies show that interaural pitch discrimination for SSD-CI listeners is highly susceptible to contextual biases, questioning its utility for establishing interaural frequency alignment. Here, we replicate this finding for SSD-CI listeners and show that these biases also extend to BI-CI listeners. To assess the testing-range bias, three ranges of comparison electrodes (BI-CI) or pure-tone frequencies (SSD-CI) were tested: full range, apical/lower half, or basal/upper half. To assess the reference bias, the reference electrode was either held fixed throughout a testing block or randomly chosen from three electrodes (basal end, middle, or apical end of the array). Results showed no effect of reference electrode randomization, but a large testing range bias; changing the center of the testing-range shifted the pitch match by an average 63 % (BI-CI) or 43 % (SSD-CI) of the change magnitude. This bias diminished pitch-match accuracy, with a change in reference electrode shifting the pitch match only an average 34 % (BI-CI) or 40 % (SSD-CI) of the expected amount. Because these effects extended to the relatively more symmetric BI-CI listeners, the results suggest that the bias cannot be attributed to interaural asymmetry. Unless the range effect can be minimized or accounted for, a pitch-discrimination task will produce interaural place-of-stimulation estimates that are highly influenced by the conditions tested, rather than reflecting a true interaural place-pitch comparison.
Collapse
|
21
|
Guérit F, Marozeau J, Deeks JM, Epp B, Carlyon RP. Effects of the relative timing of opposite-polarity pulses on loudness for cochlear implant listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:2751. [PMID: 30522299 DOI: 10.1121/1.5070150] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Accepted: 10/19/2018] [Indexed: 06/09/2023]
Abstract
The symmetric biphasic pulses used in contemporary cochlear implants (CIs) consist of both cathodic and anodic currents, which may stimulate different sites on spiral ganglion neurons and, potentially, interact with each other. The effect on the order of anodic and cathodic stimulation on loudness at short inter-pulse intervals (IPIs; 0-800 μs) is investigated. Pairs of opposite-polarity pseudomonophasic (PS) pulses were used and the amplitude of each pulse was manipulated independently. In experiment 1 the two PS pulses differed in their current level in order to elicit the same loudness when presented separately. Six users of the Advanced Bionics CI (Valencia, CA) loudness-ranked trains of the pulse pairs using a midpoint-comparison procedure. Stimuli with anodic-leading polarity were louder than those with cathodic-leading polarity for IPIs shorter than 400 μs. This effect was small-about 0.3 dB-but consistent across listeners. When the same procedure was repeated with both PS pulses having the same current level (experiment 2), anodic-leading stimuli were still louder than cathodic-leading stimuli at very short intervals. However, when using symmetric biphasic pulses (experiment 3) the effect disappeared at short intervals and reversed at long intervals. Possible peripheral sources of such polarity interactions are discussed.
Collapse
Affiliation(s)
- François Guérit
- Hearing Systems Group, Department of Electrical Engineering, Technical University of Denmark, 352 Ørsteds Plads, Kongens Lyngby, 2800, Denmark
| | - Jeremy Marozeau
- Hearing Systems Group, Department of Electrical Engineering, Technical University of Denmark, 352 Ørsteds Plads, Kongens Lyngby, 2800, Denmark
| | - John M Deeks
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, United Kingdom
| | - Bastian Epp
- Hearing Systems Group, Department of Electrical Engineering, Technical University of Denmark, 352 Ørsteds Plads, Kongens Lyngby, 2800, Denmark
| | - Robert P Carlyon
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, United Kingdom
| |
Collapse
|
22
|
Charan RMC, Ali H, Hansen JHL. Testing paradigms for assistive hearing devices in diverse acoustic environments. INTERSPEECH 2018; 2018:1686-1690. [PMID: 34307637 PMCID: PMC8297665 DOI: 10.21437/interspeech.2018-1471] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Many individuals worldwide are at risk of hearing loss due to unsafe acoustical exposure and chronic listening experience using personal audio devices. Assistive hearing devices(AHD), such as hearing-aids(HAs) and cochlear-implants(CIs) are a common choice for the restoration and rehabilitation of the auditory function. Audio sound processors in CIs and HAs operate within limits, prescribed by audiologists, not only for acceptable sound perception but also for safety reasons. Signal processing(SP) engineers follow best design practices to ensure reliable performance and incorporate necessary safety checks within the design of SP strategies to ensure safety limits are never exceeded irrespective of acoustic environments. This paper proposes a comprehensive testing and evaluation paradigm to investigate the behavior of audio devices that addresses the safety concerns in diverse acoustic conditions. This is achieved by characterizing the performance of devices with large amounts of acoustic inputs and monitoring the output behavior. The CCi-MOBILE Research-Interface(RI) (used for CI/HA research) is used in this study as the testing paradigm. Factors such as pulse-width(PW), inter-phase gap(IPG) and a number of other parameters are estimated to evaluate the impact of AHDs on hearing comfort, subjective sound quality and characterize audio devices in terms of listening perception and biological safety.
Collapse
Affiliation(s)
- Ram M C Charan
- Cochlear Implant Laboratory - Center for Robust Speech Systems The University of Texas at Dallas, Richardson TX, USA
| | - Hussnain Ali
- Cochlear Implant Laboratory - Center for Robust Speech Systems The University of Texas at Dallas, Richardson TX, USA
| | - John H L Hansen
- Cochlear Implant Laboratory - Center for Robust Speech Systems The University of Texas at Dallas, Richardson TX, USA
| |
Collapse
|
23
|
Deprez H, Gransier R, Hofmann M, Wouters J, Verhaert N. Development and validation of a method to record electrophysiological responses in direct acoustic cochlear implant subjects. Hear Res 2018; 370:217-231. [PMID: 30213516 DOI: 10.1016/j.heares.2018.08.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 07/30/2018] [Accepted: 08/14/2018] [Indexed: 11/25/2022]
Abstract
Acoustic hearing implants, such as direct acoustic cochlear implants (DACIs), can be used to treat profound mixed hearing loss. Electrophysiological responses in DACI subjects are of interest to confirm auditory processing intra-operatively, and to assist DACI fitting postoperatively. We present two related studies, focusing on DACI artifacts and electrophysiological measurements in DACI subjects, respectively. In the first study we aimed to characterize DACI artifacts, to study the feasibility of measuring frequency-specific electrophysiological responses in DACI subjects. Measurements of DACI artifacts were collected in a cadaveric head to disentangle possible DACI artifact sources and compared to a constructed DACI artifact template. It is shown that for moderate stimulation levels, DACI artifacts are mainly dominated by the artifact from the radio frequency (RF) communication signal, that can be modeled if the RF encoding protocol is known. In a second study, the feasibility of measuring intra-operative responses, without applying the RF artifact models, in DACI subjects is investigated. Auditory steady-state and brainstem responses were measured intra-operatively in three DACI subjects, immediately after implantation, to confirm proper DACI functioning and coupling to the inner ear. Intra-operative responses could be measured in two of the three tested subjects. Absence of intra-operative responses in the third subject can possibly be explained by the hearing loss, attenuation of intra-operative responses, the difference between electrophysiological and behavioral threshold, and a temporary threshold shift due to the DACI surgery. In conclusion, RF artifacts can be modeled, such that electrophysiological responses to frequency-specific stimuli could possibly be measured in DACI subjects, and intra-operative responses in DACI subjects can be obtained.
Collapse
Affiliation(s)
- Hanne Deprez
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49, 3000, Leuven, Belgium.
| | - Robin Gransier
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Michael Hofmann
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Jan Wouters
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Nicolas Verhaert
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49, 3000, Leuven, Belgium; University Hospitals Leuven, Department of Otolaryngology, Head and Neck Surgery, 3000, Leuven, Belgium
| |
Collapse
|