1
|
Chen TL, Hsiao TC, Chuang HC, Ting YC, Wang CH. A mobile platform for characterizing on-road tailpipe emissions and toxicity of ultrafine particles under real driving Conditions. ENVIRONMENTAL RESEARCH 2023; 216:114523. [PMID: 36270534 DOI: 10.1016/j.envres.2022.114523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 10/01/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Acute exposure to fresh traffic-related air pollutants (TRAPs) can be high for road users, including motorbike drivers, cyclists, and pedestrians. However, evaluating the toxicity of fresh traffic emissions from on-road vehicles is challenging since pollution properties can change dynamically within a short distance and time. This study demonstrated a mobile platform equipped with an On-Board Diagnostic II (OBDII) system, a tailor-made portable emission measurement system, and an electrostatic air-liquid interface exposure system with human monocytic THP-1 cells to characterize on-road tailpipe emissions under real driving conditions. High number concentrations up to 106-107 # cm-3 of ultrafine particles (UFPs) were observed for a gasoline engine at the cold-start stage and a diesel engine during particulate filter regeneration. In particular, a substantial fraction of freshly emitted UFPs within the size less than 23 nm were observed and should be cautioned. The potential toxicity of fresh TRAPs was quantified by cell viability, cytotoxicity, oxidative stress, and inflammatory biomarkers. Results show that the decreased cell viability, increased lactate dehydrogenase (LDH) activity, and high oxidative stress induced by the fresh TRAPs were potentially contributed by gaseous pollutants as well as particles, especially driving with the high idling frequency. Moreover, the dominant contributor to the toxicity is different for gasoline's and diesel's TRAPs. Characterizing on-road air pollutant toxicity as well as physicochemical properties using an innovative mobile platform can fill this knowledge gap.
Collapse
Affiliation(s)
- Tse-Lun Chen
- Graduate Institute of Environmental Engineering, National Taiwan University, Taipei, Taiwan
| | - Ta-Chih Hsiao
- Graduate Institute of Environmental Engineering, National Taiwan University, Taipei, Taiwan; Research Center for Environmental Changes, Academia Sinica, Taipei, Taiwan.
| | - Hsiao-Chi Chuang
- School of Respiratory Therapy, College of Medicine, Taipei Medical University, Taipei, Taiwan; Division of Pulmonary Medicine, Department of Internal Medicine, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan; Cell Physiology and Molecular Image Research Center, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.
| | - Yu-Chieh Ting
- Graduate Institute of Environmental Engineering, National Taiwan University, Taipei, Taiwan
| | - Chen-Hua Wang
- Graduate Institute of Environmental Engineering, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
2
|
Bruggink S, Kentch K, Kronenfeld J, Renquist BJ. A Leak-Free Head-Out Plethysmography System to Accurately Assess Lung Function in Mice. J Appl Physiol (1985) 2022; 133:104-118. [DOI: 10.1152/japplphysiol.00835.2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Mice are a valuable model for elegant studies of complex, systems-dependent diseases, including pulmonary diseases. Current tools to assess lung function in mice are either terminal or lack accuracy. We set out to develop a low-cost, accurate, head-out variable-pressure plethysmography system to allow for repeated, non-terminal measurements of lung function in mice. Current head-out plethysmography systems are limited by air leaks that prevent accurate measures of volume and flow. We designed an inflatable cuff that encompasses the mouse's neck preventing air leak. We wrote corresponding software to collect and analyze the data, remove movement artifacts, and automatically calibrate each dataset. This software calculates inspiratory/expiratory volume, inspiratory/expiratory time, breaths per minute, mid-expiratory flow, and end-inspiratory pause. To validate the use, we established that our plethysmography system accurately measured tidal breathing, the bronchoconstrictive response to methacholine, sex and age associated changes in breathing, and breathing changes associated with house dust mite sensitization. Our estimates of volume, flow, and timing of breaths are in line with published estimates, we observed dose-dependent decreases in volume and flow in response to methacholine (P < 0.05), increased lung volume and decreased breathing rate with aging (P < 0.05), and that house dust mite sensitization decreased volume and flow (P <0.05) while exacerbating the methacholine induced increases in inspiratory and expiratory time (P < 0.05). We describe an accurate, sensitive, low-cost, head-out plethysmography system that allows for longitudinal studies of pulmonary disease in mice.
Collapse
Affiliation(s)
- Stephanie Bruggink
- Animal and Comparative Biomedical Sciences, University of Arizona, Tucson, AZ, United States
- Physiological Sciences GIDP, University of Arizona, Tucson, AZ, United States
| | - Kyle Kentch
- Animal and Comparative Biomedical Sciences, University of Arizona, Tucson, AZ, United States
| | - Jason Kronenfeld
- Animal and Comparative Biomedical Sciences, University of Arizona, Tucson, AZ, United States
| | - Benjamin Jennings Renquist
- Animal and Comparative Biomedical Sciences, University of Arizona, Tucson, AZ, United States
- Physiological Sciences GIDP, University of Arizona, Tucson, AZ, United States
| |
Collapse
|
3
|
Hua-Huy T, Le-Dong NN, Duong-Quy S, Bei Y, Rivière S, Tiev KP, Nicco C, Chéreau C, Batteux F, Dinh-Xuan AT. Increased exhaled nitric oxide precedes lung fibrosis in two murine models of systemic sclerosis. J Breath Res 2015; 9:036007. [PMID: 26079155 DOI: 10.1088/1752-7155/9/3/036007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Exhaled nitric oxide (NO) is increased as a result of lung inflammation, which in turn causes subsequent interstitial lung disease in patients with systemic sclerosis (SSc). However, the exact time course of inflammatory and fibrotic changes in the SSc lung has not yet been described. Our objective was to assess the chronological evolution of lung inflammatory and fibrotic processes in mice pre-treated with hypochlorous acid (HOCl) or bleomycin. C57BL/6 mice were randomized into three groups receiving subcutaneous injections of HOCl, bleomycin, or PBS for 2, 4 or 6 weeks. Exhaled NO (eNO) was measured at the end of each injection period and after 2 resting weeks without injection (8 week group). Mice were then sacrificed to obtain skin and lung tissues to measure fibrotic changes and NO synthases (NOS) expression. Increased eNO, inducible NOS and nitrotyrosine expression in bronchial epithelium, lung neutrophils and macrophages were observed at early phases in both HOCl- and bleomycin-treated mice. Conversely, lung vascular endothelial NOS expression decreased significantly at 6th and 8th weeks. Skin fibrosis was significantly increased from the 4th week and lung fibrosis from 6th week. We conclude that lung inflammation occurs early after injury as reflected by increased exhaled NO and inducible NOS expression, and precedes fibrotic changes in skin and lungs of mice pre-treated with bleomycin and HOCl. Early detection and treatment of pulmonary inflammation might be useful in preventing subsequent occurrence of lung fibrosis in SSc patients.
Collapse
Affiliation(s)
- Thong Hua-Huy
- Paris Descartes University, Department of Physiology, Sorbonne Paris Cité, Cochin Hospital, 27 rue du faubourg Saint-Jacques, 75679 Paris Cedex 14, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Sun M, Zhao X, Yin H, Wang Z, Jiang C, Liu W, Chen Z, Yuan Y, Li Y, Wang C. Study of breath acetone and its correlations with blood glucose and blood beta-hydroxybutyrate using an animal model with lab-developed type 1 diabetic rats. RSC Adv 2015. [DOI: 10.1039/c5ra07084h] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
We report for the first time a study of breath acetone and its correlations with blood glucose (BG) and blood β-hydroxybutyrate (BHB) using an animal model of rats.
Collapse
|
5
|
The Influence of L-NAME on iNOS Expression and Markers of Oxidative Stress in Allergen-Induced Airway Hyperreactivity. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2014; 838:1-10. [DOI: 10.1007/5584_2014_62] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
6
|
Barbour AG, Hirsch CM, Ghalyanchi Langeroudi A, Meinardi S, Lewis ERG, Estabragh AS, Blake DR. Elevated carbon monoxide in the exhaled breath of mice during a systemic bacterial infection. PLoS One 2013; 8:e69802. [PMID: 23936104 PMCID: PMC3729689 DOI: 10.1371/journal.pone.0069802] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2013] [Accepted: 06/13/2013] [Indexed: 11/18/2022] Open
Abstract
Blood is the specimen of choice for most laboratory tests for diagnosis and disease monitoring. Sampling exhaled breath is a noninvasive alternative to phlebotomy and has the potential for real-time monitoring at the bedside. Improved instrumentation has advanced breath analysis for several gaseous compounds from humans. However, application to small animal models of diseases and physiology has been limited. To extend breath analysis to mice, we crafted a means for collecting nose-only breath samples from groups and individual animals who were awake. Samples were subjected to gas chromatography and mass spectrometry procedures developed for highly sensitive analysis of trace volatile organic compounds (VOCs) in the atmosphere. We evaluated the system with experimental systemic infections of severe combined immunodeficiency Mus musculus with the bacterium Borrelia hermsii. Infected mice developed bacterial densities of ∼107 per ml of blood by day 4 or 5 and in comparison to uninfected controls had hepatosplenomegaly and elevations of both inflammatory and anti-inflammatory cytokines. While 12 samples from individual infected mice on days 4 and 5 and 6 samples from uninfected mice did not significantly differ for 72 different VOCs, carbon monoxide (CO) was elevated in samples from infected mice, with a mean (95% confidence limits) effect size of 4.2 (2.8–5.6), when differences in CO2 in the breath were taken into account. Normalized CO values declined to the uninfected range after one day of treatment with the antibiotic ceftriaxone. Strongly correlated with CO in the breath were levels of heme oxygenase-1 protein in serum and HMOX1 transcripts in whole blood. These results (i) provide further evidence of the informativeness of CO concentration in the exhaled breath during systemic infection and inflammation, and (ii) encourage evaluation of this noninvasive analytic approach in other various other rodent models of infection and for utility in clinical management.
Collapse
Affiliation(s)
- Alan G Barbour
- Departments of Medicine and Microbiology & Molecular Genetics, University of California Irvine, Irvine, California, USA.
| | | | | | | | | | | | | |
Collapse
|
7
|
Le-Dong NN, Duong-Quy S, Bei Y, Hua-Huy T, Chen W, Dinh-Xuan AT. Measuring exhaled nitric oxide in animal models: methods and clinical implications. J Breath Res 2012; 6:047001. [PMID: 22990104 DOI: 10.1088/1752-7155/6/4/047001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Animal models such as rats and mice are useful for studying the multiple roles of nitric oxide (NO) in various respiratory disorders. The production of NO is catalyzed by the three isoforms of the enzymes (NO synthases; NOS). Indirect assessment of NOS gene or protein expression only provides partial information on the role of NO in health and lung disease. NO can also be measured in exhaled air by invasive or non-invasive approaches as a direct and quantitative marker of NO production in animal models. Whilst addressing the different methods of exhaled NO analysis in small animals (rats and mice), this review also focuses on the possible clinical implications, and discusses the advantages and limitations of these methods.
Collapse
Affiliation(s)
- Nhât-Nam Le-Dong
- Paris Descartes University, Medical School, Assistance Publique Hôpitaux de Paris, Service de Physiologie-Explorations Fonctionnelles. Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014 Paris, France
| | | | | | | | | | | |
Collapse
|
8
|
Diaz EA, Chung Y, Papapostolou V, Lawrence J, Long MS, Hatakeyama V, Gomes B, Calil Y, Sato R, Koutrakis P, Godleski JJ. Effects of fresh and aged vehicular exhaust emissions on breathing pattern and cellular responses--pilot single vehicle study. Inhal Toxicol 2012; 24:288-95. [PMID: 22486346 DOI: 10.3109/08958378.2012.668572] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The study presented here is a laboratory pilot study using diluted car exhaust from a single vehicle to assess differences in toxicological response between primary emissions and secondary products resulting from atmospheric photochemical reactions of gas phase compounds with O₃, OH and other radicals. Sprague Dawley rats were exposed for 5 h to either filtered room air (sham) or one of two different atmospheres: (i) diluted car exhaust (P)+Mt. Saint Helens Ash (MSHA); (ii) P+MSHA+secondary organic aerosol (SOA, formed during simulated photochemical aging of diluted exhaust). Primary and secondary gases were removed using a nonselective diffusion denuder. Continuous respiratory data was collected during the exposure, and bronchoalveolar lavage (BAL) and complete blood counts (CBC) were performed 24 h after exposure. ANOVA models were used to assess the exposure effect and to compare those effects across different exposure types. Total average exposures were 363 ± 66 μg/m³ P+MSHA and 212 ± 95 µg/m³ P+MSHA+SOA. For both exposures, we observed decreases in breathing rate, tidal and minute volumes (TV, MV) and peak and median flows (PIF, PEF and EF50) along with increases in breathing cycle times (Ti, Te) compared to sham. These results indicate that the animals are changing their breathing pattern with these test atmospheres. Exposure to P+MSHA+SOA produced significant increases in total cells, macrophages and neutrophils in the BAL and in vivo chemiluminescence of the lung. There were no significant differences in CBC parameters. Our data suggest that simulated atmospheric photochemistry, producing SOA in the P+MSHA+SOA exposures, enhanced the toxicity of vehicular emissions.
Collapse
Affiliation(s)
- Edgar A Diaz
- Department of Environmental Health, Harvard School of Public Health, Boston, MA 02115, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Guamán AV, Carreras A, Calvo D, Agudo I, Navajas D, Pardo A, Marco S, Farré R. Rapid detection of sepsis in rats through volatile organic compounds in breath. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 881-882:76-82. [DOI: 10.1016/j.jchromb.2011.12.001] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 11/28/2011] [Accepted: 12/02/2011] [Indexed: 11/28/2022]
|
10
|
Ameredes BT. Translating airway biomarker information into practice: from theoretical science to applied medicine. Pulm Pharmacol Ther 2010; 24:187-92. [PMID: 20883807 DOI: 10.1016/j.pupt.2010.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2010] [Accepted: 09/21/2010] [Indexed: 11/17/2022]
Abstract
Biomarkers ranging from simple to sophisticated have been used by man for many years of his existence. The main use for biomarkers over that time has been to assess relative states health and well-being, including the presence of functional limitations that presage debilitation and even death. In recent years, there has been intense interest in the development of non-invasive biomarkers to accurately predict disease state and progression, as well as potential drug therapy to assist in early mitigation of morbidity and possibly, forestall premature mortality. The development of biomarkers of airway status has followed a similar pattern, and in recent years, several biomarkers have followed the progression from basic and pre-clinical development, to clinical/translational application, and finally to potential clinical therapeutic application. Inherent in this progression is the refinement of technology that has allowed measurement of these biomarkers in a fast, convenient, and reliable fashion, such that they can be obtainable within a clinical practice setting, to allow the physician to make treatment decisions for diseases such as asthma and COPD. While the clinical therapeutic application of airway biomarkers such as exhaled nitric oxide and β(2)-adrenoreceptor Arg-16 polymorphism are still in their infancy, they have followed this common pathway of development, and now will require some years of application to demonstrate their true utility as predictive biomarkers of airway status and treatment response.
Collapse
Affiliation(s)
- Bill T Ameredes
- Division of Pulmonary, Allergy, and Critical Care Medicine, Department of Internal Medicine, University of Texas Medical Branch, Medical Research Building 8.104, 301 University Blvd., Galveston, TX 77555-1083, USA.
| |
Collapse
|
11
|
Vautz W, Nolte J, Bufe A, Baumbach JI, Peters M. Analyses of mouse breath with ion mobility spectrometry: a feasibility study. J Appl Physiol (1985) 2010; 108:697-704. [PMID: 20075263 DOI: 10.1152/japplphysiol.00658.2009] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Exhaled breath can provide comprehensive information about the metabolic state of the subject. Breath analysis carried out during animal experiments promises to increase the information obtained from a particular experiment significantly. This feasibility study should demonstrate the potential of ion mobility spectrometry for animal breath analysis, even for mice. In the framework of the feasibility study, an ion mobility spectrometer coupled with a multicapillary column for rapid preseparation was used to analyze the breath of orotracheally intubated spontaneously breathing mice during anesthesia for the very first time. The sampling procedure was validated successfully. Furthermore, the breath of four mice (2 healthy control mice, 2 with allergic airway inflammation) was analyzed. Twelve peaks were identified directly by comparison with a database. Additional mass spectrometric analyses were carried out for validation and for identification of unknown signals. Significantly different patterns of metabolites were detected in healthy mice compared with asthmatic mice, thus demonstrating the feasibility of analyzing mouse breath with ion mobility spectrometry. However, further investigations including a higher animal number for validation and identification of unknown signals are needed. Nevertheless, the results of the study demonstrate that the method is capable of rapid analyses of the breath of mice, thus significantly increasing the information obtained from each particular animal experiment.
Collapse
Affiliation(s)
- Wolfgang Vautz
- ISAS-Institute for Analytical Sciences, Department of Metabolomics, Bunsen-Kirchhoff-Strasse 11, 44139 Dortmund, Germany.
| | | | | | | | | |
Collapse
|
12
|
Ahmad T, Mabalirajan U, Joseph DA, Makhija L, Singh VP, Ghosh B, Agrawal A. Exhaled nitric oxide estimation by a simple and efficient noninvasive technique and its utility as a marker of airway inflammation in mice. J Appl Physiol (1985) 2009; 107:295-301. [PMID: 19407252 DOI: 10.1152/japplphysiol.00235.2009] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Allergic airway inflammation (AI) is commonly associated with enhanced exhaled nitric oxide (ENO) in both humans and mice. Since mouse models are being used to understand various mechanisms of asthma, a noninvasive, simple, and reproducible method to determine ENO in mice is required for serial nonterminal assessment that can be used independent of environmental situations in which the ambient air contains substantial amounts of NO as a contaminant. The aim of this study was to noninvasively measure ENO in individual mice and to test its utility as a marker of AI in different models of allergic AI. We modified the existing ENO measuring methods by incorporating flushing and washout steps that allowed simple but reliable measurements under highly variable ambient NO conditions (1-100 ppb). This method was used to serially follow ENO in acute and chronic models of allergic AI in mice. ENO was reproducibly measured by this modified method and was positively correlated to AI in both acute and chronic models of asthma but was not independently related to airway remodeling. Resolution of AI and other related parameters in dexamethasone-treated mice resulted in reduction of ENO, further confirming this association. Restriction of allergen challenge to pulmonary but not nasal airways was associated with a smaller increase in ENO compared with allergen challenge to both. Hence, ENO can now be reliably measured in mice independent of ambient NO levels and is a valid biomarker for AI. However, nasal and pulmonary airways are likely to be independent sources of ENO, and any results must be interpreted as such.
Collapse
Affiliation(s)
- Tanveer Ahmad
- Centre of Excellence for Translational Research in Asthma and Lung disease (TRiAL), Institute of Genomics and Integrative Biology, Delhi, India
| | | | | | | | | | | | | |
Collapse
|
13
|
Torres R, Herrerias A, Serra-Pagès M, Roca-Ferrer J, Pujols L, Marco A, Picado C, de Mora F. An intranasal selective antisense oligonucleotide impairs lung cyclooxygenase-2 production and improves inflammation, but worsens airway function, in house dust mite sensitive mice. Respir Res 2008; 9:72. [PMID: 19014484 PMCID: PMC2600823 DOI: 10.1186/1465-9921-9-72] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2008] [Accepted: 11/12/2008] [Indexed: 01/11/2023] Open
Abstract
Background Despite its reported pro-inflammatory activity, cyclooxygenase (COX)-2 has been proposed to play a protective role in asthma. Accordingly, COX-2 might be down-regulated in the airway cells of asthmatics. This, together with results of experiments to assess the impact of COX-2 blockade in ovalbumin (OVA)-sensitized mice in vivo, led us to propose a novel experimental approach using house dust mite (HDM)-sensitized mice in which we mimicked altered regulation of COX-2. Methods Allergic inflammation was induced in BALBc mice by intranasal exposure to HDM for 10 consecutive days. This model reproduces spontaneous exposure to aeroallergens by asthmatic patients. In order to impair, but not fully block, COX-2 production in the airways, some of the animals received an intranasal antisense oligonucleotide. Lung COX-2 expression and activity were measured along with bronchovascular inflammation, airway reactivity, and prostaglandin production. Results We observed impaired COX-2 mRNA and protein expression in the lung tissue of selective oligonucleotide-treated sensitized mice. This was accompanied by diminished production of mPGE synthase and PGE2 in the airways. In sensitized mice, the oligonucleotide induced increased airway hyperreactivity (AHR) to methacholine, but a substantially reduced bronchovascular inflammation. Finally, mRNA levels of hPGD synthase remained unchanged. Conclusion Intranasal antisense therapy against COX-2 in vivo mimicked the reported impairment of COX-2 regulation in the airway cells of asthmatic patients. This strategy revealed an unexpected novel dual effect: inflammation was improved but AHR worsened. This approach will provide insights into the differential regulation of inflammation and lung function in asthma, and will help identify pharmacological targets within the COX-2/PG system.
Collapse
Affiliation(s)
- Rosa Torres
- Department of Pneumology and Respiratory Allergy, Hospital Clínic, IDIBAPS, Universitat de Barcelona, Barcelona, Spain.
| | | | | | | | | | | | | | | |
Collapse
|