1
|
Wang N, Zhang J, Xiao B, Chen A. Microfluidic-assisted integrated nucleic acid test strips for POCT. Talanta 2024; 267:125150. [PMID: 37672986 DOI: 10.1016/j.talanta.2023.125150] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/16/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
Numerous diseases have posed significant threats to public health, notably the global pandemic of COVID-19, resulting in widespread devastation due to its high infectivity and severity. The nucleic acid lateral flow assay (NALFA) addresses challenges of complexity, cost, and time associated with traditional assays, offering a reliable platform for rapid and precise nucleic acid target detection. NALFA is gaining prominence as a point-of-care testing (POCT) technique, thanks to its user-friendly operation and rapid results. Nevertheless, conventional NALFA relies on specialized technicians and involves labor-intensive steps like DNA extraction and PCR processes, impeding its efficiency. To overcome these limitations, integrating NALFA with microfluidic technology, widely employed in rapid field detection, holds promise. This review comprehensively outlines prevailing strategies for integrating NALFA, encompassing both research initiatives and commercial applications. Addressing the bottleneck of nucleic acid amplification as a rate-limiting step, the review delves into progress in amplification-free NALFA and highlights prevalent signal amplification techniques. Ultimately, the review outlines the future prospect of integrated NALFA development, capturing the technology's evolution and providing valuable insights for academic and commercial endeavors.
Collapse
Affiliation(s)
- Nan Wang
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Juan Zhang
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Bin Xiao
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Ailiang Chen
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China.
| |
Collapse
|
2
|
Kim S, Lee S, Zhang Y, Park S, Gu J. Carbon-Based Radar Absorbing Materials toward Stealth Technologies. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2303104. [PMID: 37735148 PMCID: PMC10646258 DOI: 10.1002/advs.202303104] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/10/2023] [Indexed: 09/23/2023]
Abstract
Stealth technology is used to enhance the survival of military equipment in the field of military surveillance, as it utilizes a combination of techniques to render itself undetectable by enemy radar systems. Radar absorbing materials (RAMs) are specialized materials used to reduce the reflection (or absorption) of radar signals to provide stealth capability, which is a core component of passive countermeasures in military applications. The properties of RAMs can be optimized by adjusting their composition, microstructure, and surface geometry. Carbon-based materials present a promising approach for the fabrication of ultrathin, versatile, and high-performance RAMs due to their large specific surface area, lightweight, excellent dielectric properties, high electrical conductivity, and stability under harsh conditions. This review begins with a brief history of stealth technology and an introduction to electromagnetic waves, radar systems, and radar absorbing materials. This is followed by a discussion of recent research progress in carbon-based RAMs, including carbon blacks, carbon fibers, carbon nanotubes, graphite, graphene, and MXene, along with an in-depth examination of the principles and strategies on electromagnetic attenuation characteristics. Hope this review will offer fresh perspectives on the design and fabrication of carbon-based RAMs, thereby fostering a deeper fundamental understanding and promoting practical applications.
Collapse
Affiliation(s)
- Seong‐Hwang Kim
- Department of ChemistryInha University100 InharoIncheon22212South Korea
| | - Seul‐Yi Lee
- Department of ChemistryInha University100 InharoIncheon22212South Korea
| | - Yali Zhang
- Shaanxi Key Laboratory of Macromolecular Science and TechnologySchool of Chemistry and Chemical EngineeringNorthwestern Polytechnical UniversityXi'anShaanxi710072P. R. China
| | - Soo‐Jin Park
- Department of ChemistryInha University100 InharoIncheon22212South Korea
| | - Junwei Gu
- Shaanxi Key Laboratory of Macromolecular Science and TechnologySchool of Chemistry and Chemical EngineeringNorthwestern Polytechnical UniversityXi'anShaanxi710072P. R. China
| |
Collapse
|
3
|
|
4
|
Current Developments in Diagnostic Assays for Laboratory Confirmation and Investigation of Botulism. J Clin Microbiol 2021; 60:e0013920. [PMID: 34586891 DOI: 10.1128/jcm.00139-20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Detection of botulinum neurotoxin or isolation of the toxin producing organism is required for the laboratory confirmation of botulism in clinical specimens. In an effort to reduce animal testing required by the gold standard method of botulinum neurotoxin detection, the mouse bioassay, many technologies have been developed to detect and characterize the causative agent of botulism. Recent advancements in these technologies have led to improvements in technical performance of diagnostic assays; however, many emerging assays have not been validated for the detection of all serotypes in complex clinical and environmental matrices. Improvements to culture protocols, endopeptidase-based assays, and a variety of immunological and molecular methods have provided laboratories with a variety of testing options to evaluate and incorporate into their testing algorithms. While significant advances have been made to improve these assays, additional work is necessary to evaluate these methods in various clinical matrices and to establish standardized criteria for data analysis and interpretation.
Collapse
|
5
|
Soliman R, Magdy MM, Samir A, Abdalla YA, Sayed RH. Development of immunochromatographic lateral flow test for rapid detection of Clostridium perfringens α, β and ε toxins in clinical samples. BULGARIAN JOURNAL OF VETERINARY MEDICINE 2021. [DOI: 10.15547/bjvm.2019-0131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
In the present work a lateral flow immunochromatographic test (LFT) for rapid detection of Clostridium perfringens toxins types, alpha (α), beta (β) and epsilon (ε) in clinical samples was developed. C. perfringens toxins were prepared, purified and inactivated with 0.2% formalin. Polyclonal antibodies specific to C. perfringens toxins types α, β and ε toxoids were prepared in rabbits and guinea pigs. The toxoid specific polyclonal antibodies prepared in rabbits were labelled with gold chloride nanoparticles. The prepared toxin specific rabbit and guinea pigs antibodies and goat anti-rabbit antibodies were utilised in development of a lateral flow immunochromatographic test and the latter - evaluated for detection of C. perfringens α, β and ε toxins in clinical samples. The sensitivity and specificity and accuracy of the developed LFT were determined by comparison with a commercially available ELISA used for detection of these toxins. The prepared LFT was capable to detect C. perfringens α, β and ε toxins in quantities of 2 μg/ml, 250 ng/ml and 60 ng/ml, respectively. One hundred poultry suspected faecal samples was examined both with the prepared LFT and commercial ELISA to test the validity of developed LFT. The sensitivity, specificity and accuracy of the LFT for detection of C. perfringens toxins were 81%, 95.2% and 90%, respectively, for α toxin, 76.6%, 98.5% and 72%, respectively, for β toxin and 66.6%, 98.8% and 95%, respectively, for ε toxin.
Collapse
Affiliation(s)
- R Soliman
- Microbiology Department, Faculty of Veterinary Medicine, Cairo University, Egypt
| | | | - A. Samir
- Microbiology Department, Faculty of Veterinary Medicine, Cairo University, Egypt
| | - Y. A. Abdalla
- Anaerobic Vaccine Department, Veterinary Serum and Vaccine Research Institute (VSVRI), Abbasia, Cairo, Egypt
| | - R. H. Sayed
- Central Laboratory for Evaluation of Veterinary Biologics (CLEVB, ARC), Abbasia, Cai-ro, Egypt
| |
Collapse
|
6
|
Chan WS, Wong GF, Hung CW, Wong YN, Fung KM, Lee WK, Dao KL, Leung CW, Lo KM, Lee WM, Cheung BKK. Interpol review of toxicology 2016-2019. Forensic Sci Int Synerg 2020; 2:563-607. [PMID: 33385147 PMCID: PMC7770452 DOI: 10.1016/j.fsisyn.2020.01.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/23/2020] [Indexed: 12/13/2022]
Abstract
This review paper covers the forensic-relevant literature in toxicology from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.int/content/download/14458/file/Interpol%20Review%20.Papers%202019.pdf.
Collapse
|
7
|
Klisara N, Yu YM, Palaniappan A, Liedberg B. Towards on-site visual detection of proteases in food matrices. Anal Chim Acta 2019; 1078:182-188. [DOI: 10.1016/j.aca.2019.06.037] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/22/2019] [Accepted: 06/17/2019] [Indexed: 12/31/2022]
|
8
|
Hobbs RJ, Thomas CA, Halliwell J, Gwenin CD. Rapid Detection of Botulinum Neurotoxins-A Review. Toxins (Basel) 2019; 11:E418. [PMID: 31319550 PMCID: PMC6669533 DOI: 10.3390/toxins11070418] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 07/15/2019] [Accepted: 07/15/2019] [Indexed: 12/13/2022] Open
Abstract
A toxin is a poisonous substance produced within living cells or organisms. One of the most potent groups of toxins currently known are the Botulinum Neurotoxins (BoNTs). These are so deadly that as little as 62 ng could kill an average human; to put this into context that is approximately 200,000 × less than the weight of a grain of sand. The extreme toxicity of BoNTs leads to the need for methods of determining their concentration at very low levels of sensitivity. Currently the mouse bioassay is the most widely used detection method monitoring the activity of the toxin; however, this assay is not only lengthy, it also has both cost and ethical issues due to the use of live animals. This review focuses on detection methods both existing and emerging that remove the need for the use of animals and will look at three areas; speed of detection, sensitivity of detection and finally cost. The assays will have wide reaching interest, ranging from the pharmaceutical/clinical industry for production quality management or as a point of care sensor in suspected cases of botulism, the food industry as a quality control measure, to the military, detecting BoNT that has been potentially used as a bio warfare agent.
Collapse
Affiliation(s)
- Robert J Hobbs
- Applied Research in Chemistry and Health (ARCH) Research Group, School of Natural Sciences, Bangor University, Bangor, Gwynedd, Wales LL57 2UW, UK
| | - Carol A Thomas
- Applied Research in Chemistry and Health (ARCH) Research Group, School of Natural Sciences, Bangor University, Bangor, Gwynedd, Wales LL57 2UW, UK
| | - Jennifer Halliwell
- Applied Research in Chemistry and Health (ARCH) Research Group, School of Natural Sciences, Bangor University, Bangor, Gwynedd, Wales LL57 2UW, UK
| | - Christopher D Gwenin
- Applied Research in Chemistry and Health (ARCH) Research Group, School of Natural Sciences, Bangor University, Bangor, Gwynedd, Wales LL57 2UW, UK.
| |
Collapse
|
9
|
Frohnmeyer E, Tuschel N, Sitz T, Hermann C, Dahl GT, Schulz F, Baeumner AJ, Fischer M. Aptamer lateral flow assays for rapid and sensitive detection of cholera toxin. Analyst 2019; 144:1840-1849. [PMID: 30681077 DOI: 10.1039/c8an01616j] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Aptamers are envisioned to serve as powerful synthetic substitutes to antibodies in a variety of bioanalytical assay formats. However, lateral flow assays (LFAs) remain dominated by antibody-based strategies. In this study, a LFA for the detection of cholera toxin as a model analyte is developed and optimized using a synthetic aptamer and a naturally occurring receptor as biorecognition elements and directly compared with solely aptamer and aptamer and antibody-based alternative approaches. The aptamer (CT916) recently selected by our group, GM1 receptors and an anti-cholera toxin antibody were evaluated. Relying solely on molecules that can easily be synthesized while aiming for high sensitivity, we applied a novel combination of capture aptamer and GM1 cell receptor-labeled liposomes for cholera toxin detection, achieving a limit of detection (LOD) of 2 ng ml-1 (3σ)/10 ng ml-1 (visual) in ∼15 min. To put our novel aptasensor into perspective, we developed a competitive lateral flow assay, exploiting the competition of cholera toxin in solution with immobilized cholera toxin for binding of aptamer-coated gold nanoparticles (AuNPs) (LOD = 51 ng ml-1 (3σ)/100 ng ml-1 (visual), assay time ∼10 min). As dual simultaneously binding aptamers were not available, we designed aptamer antibody pair-based lateral flow assays using aptamer-coated AuNPs which yielded a LOD of 5 ng ml-1 (by the 3σ rule)/10 ng ml-1 (visual) in a 10 min assay and an even better LOD of 0.6 ng ml-1 (3σ)/1 ng ml-1 (visual), with an ∼20 min total assay time. All set-ups are highly specific and provide an excellent alternative for cholera toxin detection in places where professional knowledge and sophisticated equipment are not readily available and cost efficient, simple, and rapid tests are needed, while the combination of GM1 cell receptor-labeled liposomes and aptamers is clearly the most promising.
Collapse
Affiliation(s)
- Esther Frohnmeyer
- Hamburg School of Food Science, Institute of Food Chemistry, University of Hamburg, Grindelallee 117, 20146 Hamburg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Ji B, Kenaan A, Gao S, Cheng J, Cui D, Yang H, Wang J, Song J. Label-free detection of biotoxins via a photo-induced force infrared spectrum at the single-molecular level. Analyst 2019; 144:6108-6117. [DOI: 10.1039/c9an01338e] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Schematic illustration of photo-induced force microscopy combine principal component analysis detected and distinguish single molecule particles of biotoxins AT, RT/ETX with label-free.
Collapse
Affiliation(s)
- Bin Ji
- State Key Laboratory of Pathogen and Biosecurity
- Beijing Institute of Microbiology and Epidemiology
- Beijing 100071
- China
- Institute of Nano Biomedicine and Engineering
| | - Ahmad Kenaan
- Institute of Nano Biomedicine and Engineering
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument
- Department of Instrument Science and Engineering
- School of Electronic Information and Electrical Engineering
- Shanghai Jiao Tong University
| | - Shan Gao
- State Key Laboratory of Pathogen and Biosecurity
- Beijing Institute of Microbiology and Epidemiology
- Beijing 100071
- China
| | - Jin Cheng
- Institute of Nano Biomedicine and Engineering
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument
- Department of Instrument Science and Engineering
- School of Electronic Information and Electrical Engineering
- Shanghai Jiao Tong University
| | - Daxiang Cui
- Institute of Nano Biomedicine and Engineering
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument
- Department of Instrument Science and Engineering
- School of Electronic Information and Electrical Engineering
- Shanghai Jiao Tong University
| | - Hao Yang
- State Key Laboratory of Pathogen and Biosecurity
- Beijing Institute of Microbiology and Epidemiology
- Beijing 100071
- China
| | - Jinglin Wang
- State Key Laboratory of Pathogen and Biosecurity
- Beijing Institute of Microbiology and Epidemiology
- Beijing 100071
- China
| | - Jie Song
- Institute of Nano Biomedicine and Engineering
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument
- Department of Instrument Science and Engineering
- School of Electronic Information and Electrical Engineering
- Shanghai Jiao Tong University
| |
Collapse
|
11
|
Real-Time Monitoring of a Botulinum Neurotoxin Using All-Carbon Nanotube-Based Field-Effect Transistor Devices. SENSORS 2018; 18:s18124235. [PMID: 30513867 PMCID: PMC6308983 DOI: 10.3390/s18124235] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 11/23/2018] [Accepted: 11/27/2018] [Indexed: 02/01/2023]
Abstract
The possibility of exposure to botulinum neurotoxin (BoNT), a powerful and potential bioterrorism agent, is considered to be ever increasing. The current gold-standard assay, live-mouse lethality, exhibits high sensitivity but has limitations including long assay times, whereas other assays evince rapidity but lack factors such as real-time monitoring or portability. In this study, we aimed to devise a novel detection system that could detect BoNT at below-nanomolar concentrations in the form of a stretchable biosensor. We used a field-effect transistor with a p-type channel and electrodes, along with a channel comprising aligned carbon nanotube layers to detect the type E light chain of BoNT (BoNT/E-Lc). The detection of BoNT/E-Lc entailed observing the cleavage of a unique peptide and the specific bonding between BoNT/E-Lc and antibody BoNT/E-Lc (Anti-BoNT/E-Lc). The unique peptide was cleaved by 60 pM BoNT/E-Lc; notably, 52 fM BoNT/E-Lc was detected within 1 min in the device with the antibody in the bent state. These results demonstrated that an all-carbon nanotube-based device (all-CNT-based device) could be produced without a complicated fabrication process and could be used as a biosensor with high sensitivity, suggesting its potential development as a wearable BoNT biosensor.
Collapse
|
12
|
Tam CC, Flannery AR, Cheng LW. A Rapid, Sensitive, and Portable Biosensor Assay for the Detection of Botulinum Neurotoxin Serotype A in Complex Food Matrices. Toxins (Basel) 2018; 10:toxins10110476. [PMID: 30445734 PMCID: PMC6266793 DOI: 10.3390/toxins10110476] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 11/09/2018] [Accepted: 11/12/2018] [Indexed: 12/14/2022] Open
Abstract
Botulinum neurotoxin (BoNT) intoxication can lead to the disease botulism, characterized by flaccid muscle paralysis that can cause respiratory failure and death. Due to the significant morbidity and mortality costs associated with BoNTs high toxicity, developing highly sensitive, rapid, and field-deployable assays are critically important to protect the nation’s food supply against either accidental or intentional contamination. We report here that the B-cell based biosensor assay CANARY® (Cellular Analysis and Notification of Antigen Risks and Yields) Zephyr detects BoNT/A holotoxin at limits of detection (LOD) of 10.0 ± 2.5 ng/mL in assay buffer. Milk matrices (whole milk, 2% milk and non-fat milk) with BoNT/A holotoxin were detected at similar levels (7.4–7.9 ng/mL). BoNT/A complex was positive in carrot, orange, and apple juices at LODs of 32.5–75.0 ng/mL. The detection of BoNT/A complex in solid complex foods (ground beef, smoked salmon, green bean baby puree) ranged from 14.8 ng/mL to 62.5 ng/mL. Detection of BoNT/A complex in the viscous liquid egg matrix required dilution in assay buffer and gave a LOD of 171.9 ± 64.7 ng/mL. These results show that the CANARY® Zephyr assay can be a highly useful qualitative tool in environmental and food safety surveillance programs.
Collapse
Affiliation(s)
- Christina C Tam
- Foodborne Toxin Detection and Prevention Research Unit, Western Regional Research Center, Agricultural Research Services, United States Department of Agriculture, 800 Buchanan Street, Albany, CA 94710, USA.
| | | | - Luisa W Cheng
- Foodborne Toxin Detection and Prevention Research Unit, Western Regional Research Center, Agricultural Research Services, United States Department of Agriculture, 800 Buchanan Street, Albany, CA 94710, USA.
| |
Collapse
|