1
|
Fyenbo DB, Bjerre HL, Frausing MHJP, Stephansen C, Sommer A, Borgquist R, Bakos Z, Glikson M, Milman A, Beinart R, Kockova R, Sedlacek K, Wichterle D, Saba S, Jain S, Shalaby A, Kronborg MB, Nielsen JC. Targeted left ventricular lead positioning to the site of latest activation in cardiac resynchronization therapy: a systematic review and meta-analysis. Europace 2023; 25:euad267. [PMID: 37695316 PMCID: PMC10507669 DOI: 10.1093/europace/euad267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 09/06/2023] [Indexed: 09/12/2023] Open
Abstract
AIMS Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.
Collapse
Affiliation(s)
- Daniel Benjamin Fyenbo
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 11, 8200 Aarhus N, Denmark
- Diagnostic Center, Silkeborg Regional Hospital, Falkevej 1A, 8600 Silkeborg, Denmark
| | - Henrik Laurits Bjerre
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 11, 8200 Aarhus N, Denmark
| | - Maria Hee Jung Park Frausing
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 11, 8200 Aarhus N, Denmark
| | - Charlotte Stephansen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
| | - Anders Sommer
- Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark
| | | | - Zoltan Bakos
- Department of Cardiology, Kristianstad Hospital, Kristianstad, Sweden
| | - Michael Glikson
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel
- Faculty of Medicine, Hebrew University, Jerusalem, Israel
| | - Anat Milman
- Leviev Heart Institute, The Chaim Sheba Medical Center, Tel Hashomer, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Roy Beinart
- Leviev Heart Institute, The Chaim Sheba Medical Center, Tel Hashomer, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Radka Kockova
- Department of Cardiac Surgery, Na Homolce Hospital, Prague, Czech Republic
| | - Kamil Sedlacek
- 1st Department of Internal Medicine—Cardiology and Angiology, University Hospital, Hradec Králové, Czech Republic
- Faculty of Medicine, Charles University, Hradec Králové, Czech Republic
| | - Dan Wichterle
- Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Samir Saba
- Heart and Vascular Institute, Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Sandeep Jain
- Heart and Vascular Institute, Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Alaa Shalaby
- Heart and Vascular Institute, Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Mads Brix Kronborg
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 11, 8200 Aarhus N, Denmark
| | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 11, 8200 Aarhus N, Denmark
| |
Collapse
|
2
|
Allen LaPointe NM, Ali-Ahmed F, Dalgaard F, Kosinski AS, Schmidler GS, Al-Khatib SM. Outcomes of Cardiac Resynchronization Therapy with Image-Guided Left Ventricular Lead Placement at the Site of Latest Mechanical Activation: A Systematic Review and Meta-Analysis. J Interv Cardiol 2022; 2022:6285894. [PMID: 35655661 PMCID: PMC9146808 DOI: 10.1155/2022/6285894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 04/22/2022] [Indexed: 12/07/2022] Open
Abstract
Aim To assess evidence for an image-guided approach for cardiac resynchronization therapy (CRT) that targets left ventricular (LV) lead placement at the segment of latest mechanical activation. Methods A systematic review of EMBASE and PubMed was performed for randomized controlled trials (RCTs) and prospective observational studies from October 2008 through October 2020 that compared an image-guided CRT approach with a non-image-guided approach for LV lead placement. Meta-analyses were performed to assess the association between the image-guided approach and NYHA class improvement or changes in end-systolic volume (LVESV), end-diastolic volume (LVEDV), and ejection fraction (LVEF). Results From 5897 citations, 5 RCTs including 818 patients (426 image-guided and 392 non-image-guided) were identified. The mean age ranged from 66 to 71 years, 76% were male, and 53% had ischemic cardiomyopathy. Speckle tracking echocardiography was the primary image-guided method in all studies. LV lead placement within the segment of the latest mechanical activation (concordant) was achieved in the image-guided arm in 45% of the evaluable patients. There was a statistically significant improvement in the NYHA class at 6 months (odds ratio 1.66; 95% confidence interval (CI) [1.02, 2.69]) with the image-guided approach, but no statistically significant change in LVESV (MD -7.1%; 95% CI [-16.0, 1.8]), LVEDV (MD -5.2%; 95% CI [-15.8, 5.4]), or LVEF (MD 0.68; 95% CI [-4.36, 5.73]) versus the non-image-guided approach. Conclusion The image-guided CRT approach was associated with improvement in the NYHA class but not echocardiographic measures, possibly due to the small sample size and a low rate of concordant LV lead placement despite using the image-guided approach. Therefore, our meta-analysis was not able to identify consistent improvement in CRT outcomes with an image-guided approach.
Collapse
Affiliation(s)
- Nancy M. Allen LaPointe
- Department of Medicine, Duke University School of Medicine, Durham, NC 27710, USA
- Duke-Margolis Center for Health Policy, Duke University, Durham, NC 27708, USA
| | | | - Frederik Dalgaard
- Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - Andrzej S. Kosinski
- Department of Biostatistics and Bioinformatics, Duke University School of Medicine, Durham, NC 27710, USA
- Duke Clinical Research Institute, Durham, NC 27710, USA
| | - Gillian Sanders Schmidler
- Duke-Margolis Center for Health Policy, Duke University, Durham, NC 27708, USA
- Department of Population Health Sciences, Duke University School of Medicine, Durham, NC 27710, USA
| | - Sana M. Al-Khatib
- Department of Medicine, Duke University School of Medicine, Durham, NC 27710, USA
- Duke Clinical Research Institute, Durham, NC 27710, USA
- Division of Cardiology, Duke University Medical Center, Durham, NC 27710, USA
| |
Collapse
|
3
|
Nisar H, Fakim D, Bainbridge D, Chen ECS, Peters T. 3D localization of vena contracta using Doppler ICE imaging in tricuspid valve interventions. Int J Comput Assist Radiol Surg 2022; 17:1569-1577. [PMID: 35588338 PMCID: PMC9463221 DOI: 10.1007/s11548-022-02660-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 04/25/2022] [Indexed: 11/27/2022]
Abstract
Purpose Tricuspid valve (TV) interventions face the challenge of imaging the anatomy and tools because of the ‘TEE-unfriendly’ nature of the TV. In edge-to-edge TV repair, a core step is to position the clip perpendicular to the coaptation gap. In this study, we provide a semi-automated method to localize the VC from Doppler intracardiac echo (ICE) imaging in a tracked 3D space, thus providing a pre-mapped location of the coaptation gap to assist device positioning. Methods A magnetically tracked ICE probe with Doppler imaging capabilities is employed in this study for imaging three patient-specific TVs placed in a pulsatile heart phantom. For each of the valves, the ICE probe is positioned to image the maximum regurgitant flow for five cardiac cycles. An algorithm then extracts the regurgitation imaging and computes the exact location of the vena contracta on the image. Results Across the three pathological, patient-specific valves, the average distance error between the detected VC and the ground truth model is \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$({1.22 \pm 2.00})$$\end{document}(1.22±2.00)mm. For each of the valves, one case represented the outlier where the algorithm misidentified the vena contracta to be near the annulus. In such cases, it is recommended to retake the five-second imaging data. Conclusion This study presented a method for ultrasound-based localization of vena contracta in 3D space. Mapping such anatomical landmarks has the potential to assist with device positioning and to simplify tricuspid valve interventions by providing more contextual information to the interventionalists, thus enhancing their spatial awareness. Additionally, ICE can be used to provide live US and Doppler imaging of the complex TV anatomy throughout the procedure.
Collapse
Affiliation(s)
- Hareem Nisar
- Robarts Research Institute, 1151 Richmond St., London, ON, N6A5B7, Canada. .,School of Biomedical Engineering, Western University, 1151 Richmond St, London, ON, N6A3K7, Canada.
| | - Djalal Fakim
- Schulic School of Medicine and Dentistry, Western University, 1151 Richmond St., London, ON, N6A3K7, Canada
| | - Daniel Bainbridge
- Department of Anesthesia and Perioperative Medicine, London Health Sciences Centre, 339 Windermere Rd., London, ON, N6A5A5, Canada
| | - Elvis C S Chen
- Robarts Research Institute, 1151 Richmond St., London, ON, N6A5B7, Canada.,School of Biomedical Engineering, Western University, 1151 Richmond St, London, ON, N6A3K7, Canada.,Schulic School of Medicine and Dentistry, Western University, 1151 Richmond St., London, ON, N6A3K7, Canada.,Department of Medical Biophysics, Western University, 1151 Richmond St., London, ON, N6A3K7, Canada
| | - Terry Peters
- Robarts Research Institute, 1151 Richmond St., London, ON, N6A5B7, Canada.,School of Biomedical Engineering, Western University, 1151 Richmond St, London, ON, N6A3K7, Canada.,Schulic School of Medicine and Dentistry, Western University, 1151 Richmond St., London, ON, N6A3K7, Canada.,Department of Medical Biophysics, Western University, 1151 Richmond St., London, ON, N6A3K7, Canada
| |
Collapse
|
4
|
Wouters PC, van Lieshout C, van Dijk VF, Delnoy PPH, Doevendans PA, Cramer MJ, Frederix GW, van Slochteren FJ, Meine M. Advanced image-supported lead placement in cardiac resynchronisation therapy: protocol for the multicentre, randomised controlled ADVISE trial and early economic evaluation. BMJ Open 2021; 11:e054115. [PMID: 34697125 PMCID: PMC8547507 DOI: 10.1136/bmjopen-2021-054115] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
INTRODUCTION Achieving optimal placement of the left ventricular (LV) lead in cardiac resynchronisation therapy (CRT) is a prerequisite in order to achieve maximum clinical benefit, and is likely to help avoid non-response. Pacing outside scar tissue and targeting late activated segments may improve outcome. The present study will be the first randomised controlled trial to compare the efficacy of real-time image-guided LV lead delivery to conventional CRT implantation. In addition, to estimate the cost-effectiveness of targeted lead implantation, an early decision analytic model was developed, and described here. METHODS AND ANALYSIS A multicentre, interventional, randomised, controlled trial will be conducted in a total of 130 patients with a class I or IIa indication for CRT implantation. Patients will be stratified to ischaemic heart failure aetiology and 1:1 randomised to either empirical lead placement or live image-guided lead placement. Ultimate lead location and echocardiographic assessment will be performed by core laboratories, blinded to treatment allocation and patient information. Late gadolinium enhancement cardiac magnetic resonance imaging (CMR) and CINE-CMR with feature-tracking postprocessing software will be used to semi-automatically determine myocardial scar and late mechanical activation. The subsequent treatment file with optimal LV-lead positions will be fused with the fluoroscopy, resulting in live target-visualisation during the procedure. The primary endpoint is the difference in percentage of successfully targeted LV-lead location. Secondary endpoints are relative percentage reduction in indexed LV end-systolic volume, a hierarchical clinical endpoint, and quality of life. The early analytic model was developed using a Markov-model, consisting of seven mutually exclusive health states. ETHICS AND DISSEMINATION The protocol was approved by the Medical Research Ethics Committee Utrecht (NL73416.041.20). All participants are required to provide written informed consent. Results will be submitted to peer-reviewed journals. TRIAL REGISTRATION NUMBER NCT05053568; Trial NL8666.
Collapse
Affiliation(s)
- Philippe C Wouters
- Department of Cardiology, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | - Chris van Lieshout
- Department of Public Health, Healthcare Innovation & Evaluation and Medical Humanities (PHM), Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | - Vincent F van Dijk
- Department of Cardiology, Sint Antonius Ziekenhuis, Nieuwegein, The Netherlands
| | | | - Pieter Afm Doevendans
- Department of Cardiology, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | - Maarten J Cramer
- Department of Cardiology, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | - Geert Wj Frederix
- Department of Public Health, Healthcare Innovation & Evaluation and Medical Humanities (PHM), Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | | | - Mathias Meine
- Department of Cardiology, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| |
Collapse
|
5
|
Hu X, Xu H, Hassea SRA, Qian Z, Wang Y, Zhang X, Hou X, Zou J. Comparative efficacy of image-guided techniques in cardiac resynchronization therapy: a meta-analysis. BMC Cardiovasc Disord 2021; 21:255. [PMID: 34024286 PMCID: PMC8142495 DOI: 10.1186/s12872-021-02061-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 05/11/2021] [Indexed: 01/06/2023] Open
Abstract
Background Several studies have illustrated the use of echocardiography, magnetic resonance imaging, and nuclear imaging to optimize left ventricular (LV) lead placement to enhance the response of cardiac resynchronization therapy (CRT) in heart failure patients. We aimed to conduct a meta-analysis to determine the incremental efficacy of image-guided CRT over standard CRT. Methods We searched PubMed, Cochrane library, and EMBASE to identify relevant studies. The outcome measures of cardiac function and clinical outcomes were CRT response, concordance of the LV lead to the latest sites of contraction (concordance of LV), heart failure (HF) hospitalization, mortality rates, changes of left ventricular ejection fraction (LVEF), and left ventricular end-systolic volume (LVESV). Results The study population comprised 1075 patients from eight studies. 544 patients underwent image-guided CRT implantation and 531 underwent routine implantation without imaging guidance. The image-guided group had a significantly higher CRT response and more on-target LV lead placement than the control group (RR, 1.33 [95% CI, 1.21 to 1.47]; p < 0.01 and RR, 1.39 [95% CI, 1.01 to 1.92]; p < 0.05, respectively). The reduction of LVESV in the image-guided group was significantly greater than that in the control group (weighted mean difference, − 12.46 [95% CI, − 18.89 to − 6.03]; p < 0.01). The improvement in LVEF was significantly higher in the image-guided group (weighted mean difference, 3.25 [95% CI, 1.80 to 4.70]; p < 0.01). Pooled data demonstrated no significant difference in HF hospitalization and mortality rates between two groups (RR, 0.89 [95% CI, 0.16 to 5.08]; p = 0.90, RR, 0.69 [95% CI, 0.37 to 1.29]; p = 0.24, respectively). Conclusions This meta-analysis indicates that image-guided CRT is correlated with improved CRT volumetric response and cardiac function in heart failure patients but not with lower hospitalization or mortality rate. Supplementary Information The online version contains supplementary material available at 10.1186/s12872-021-02061-y.
Collapse
Affiliation(s)
- Xiao Hu
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China.,Department of Cardiology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian, Jiangsu, China
| | - Hai Xu
- Department of Cardiology, Staten Island University Hospital / Northwell Health, 475 Seaview Drive, Staten Island, NY, 10305, USA
| | - Shameer Raaj Avishkar Hassea
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China
| | - Zhiyong Qian
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China
| | - Yao Wang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China
| | - Xinwei Zhang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China
| | - Xiaofeng Hou
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China
| | - Jiangang Zou
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, No.300, Guangzhou Road, Nanjing, 210029, China.
| |
Collapse
|
6
|
Sugimoto A, Takigiku K, Shiraishi S, Takahashi M, Tsuchida M. Adverse impact of univentricular pacing for the patient with functional single ventricle: successful conversion to cardiac resynchronization therapy. Surg Case Rep 2020; 6:101. [PMID: 32405970 PMCID: PMC7221050 DOI: 10.1186/s40792-020-00863-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 05/06/2020] [Indexed: 12/02/2022] Open
Abstract
Background In a Fontan candidate, univentricular pacing may cause delay in interventricular conduction, which induces asynchronous contraction. Cardiac resynchronization therapy is expected to be an effective mode of therapy in such a case. Case presentation A 7-month-old girl, diagnosed with dextrocardia, congenitally corrected transposition of the great artery [situs solitus, L-loop, and L-transposition], ventricular septal defect, infundibular and pulmonary valvular stenosis, and straddling of the tricuspid valve, was considered as a candidate for the Fontan procedure. She had undergone Blalock-Taussig shunt, and epicardial univentricular pacemaker implantation for persistent complete atrioventricular block. She underwent a bidirectional cavopulmonary shunt concomitant with ventricular lead translocation from the morphological left ventricle to the morphological right ventricle. After discharge, ventricular dyssynchrony was noted and cardiac failure persisted. She was converted to cardiac resynchronization therapy (CRT) at 13 months of age. Two-dimensional speckle tracking imaging was used by cardiologists to determine the most suitable pacing site. CRT rapidly corrected the heart failure; thus, she underwent the Fontan procedure after 1.5 years. Five years have passed since the cardiac resynchronization therapy; her interventricular synchrony is maintained well and the level of brain natriuretic peptide remains within normal range. Conclusion We describe the successful conversion from single ventricular pacing to CRT, in a case of congenitally corrected transposition of the great artery indicated for the Fontan procedure. The long-term prognosis of cardiac resynchronization therapy is undetermined in the pediatric population; therefore, further follow-up is required.
Collapse
Affiliation(s)
- Ai Sugimoto
- Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, 1-757, Asahimachi-dori, Niigata City, 951-8510, Japan.
| | - Kiyohiro Takigiku
- Department of Pediatric Cardiology, Nagano Children's Hospital, Azumino City, Japan
| | - Shuichi Shiraishi
- Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, 1-757, Asahimachi-dori, Niigata City, 951-8510, Japan
| | - Masashi Takahashi
- Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, 1-757, Asahimachi-dori, Niigata City, 951-8510, Japan
| | - Masanori Tsuchida
- Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, 1-757, Asahimachi-dori, Niigata City, 951-8510, Japan
| |
Collapse
|
7
|
Behar JM, Mountney P, Toth D, Reiml S, Panayiotou M, Brost A, Fahn B, Karim R, Claridge S, Jackson T, Sieniewicz B, Patel N, O'Neill M, Razavi R, Rhode K, Rinaldi CA. Real-Time X-MRI-Guided Left Ventricular Lead Implantation for Targeted Delivery of Cardiac Resynchronization Therapy. JACC Clin Electrophysiol 2017; 3:803-814. [PMID: 29759775 DOI: 10.1016/j.jacep.2017.01.018] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 01/23/2017] [Accepted: 01/27/2017] [Indexed: 11/19/2022]
Abstract
OBJECTIVES This study sought to test the feasibility of a purpose-built, integrated software platform to process, analyze, and overlay cardiac magnetic resonance (CMR) data in real time within a combined cardiac catheter laboratory and magnetic resonance imaging scanner suite (X-MRI) to guide left ventricular (LV) lead implantation. BACKGROUND Suboptimal LV lead position is a major determinant of poor cardiac resynchronization therapy (CRT) response, and the optimal site is highly patient specific. Pacing myocardial scar is associated with poorer outcomes; conversely, targeting latest mechanical activation (LMA) may improve them. METHODS Fourteen patients (age 74 ± 5.1 years; New York Heart Association functional class: 2.7 ± 0.4; 86% ischemic with ejection fraction 27 ± 7.6%; QRSd: 157 ± 19 ms) underwent CMR followed by immediate CRT implantation using derived scar and dyssynchrony data, overlaid onto fluoroscopy in an X-MRI suite. Rapid LV segmentation enabled detailed scar quantification, identification of LMA segments, and selection of myocardial targets. At coronary venography, the CMR-derived 3-dimensional shell was fused, enabling identification of viable venous targets subtended by target segments for LV lead placement. RESULTS The platform was successful in all 14 patients, of whom 10 (71%) were paced in pre-procedurally defined target segments. Pacing in CMR-defined target segments (out of scar) showed a significant decrease in the LV capture threshold (mean difference: 2.4 [1.5 to 3.2]; p < 0.001) and shorter paced QRS duration (mean difference: 25 [15 to 34]; p < 0.001) compared with pacing in areas of CMR determined scar. In 5 (36%) patients with extensive scar in the posterolateral wall, CMR guidance enabled successful lead delivery in an alternative anatomically favorable site. Radiation dose and implant times were similar to historical controls (p = NS). CONCLUSIONS Real-time CMR-guided LV lead placement is feasible and achievable in a single clinical setting and may prove helpful to preferentially select sites for LV lead placement.
Collapse
Affiliation(s)
- Jonathan M Behar
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
| | - Peter Mountney
- Medical Imaging Technologies, Siemens Healthineers, Princeton, New Jersey
| | - Daniel Toth
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom; Siemens Healthineers, Frimley, Camberley, United Kingdom
| | | | - Maria Panayiotou
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | | | | | - Rashed Karim
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Simon Claridge
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Tom Jackson
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Ben Sieniewicz
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Nik Patel
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Mark O'Neill
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Reza Razavi
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Kawal Rhode
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| | - Christopher Aldo Rinaldi
- Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom
| |
Collapse
|
8
|
Behar JM, Claridge S, Jackson T, Sieniewicz B, Porter B, Webb J, Rajani R, Kapetanakis S, Carr-White G, Rinaldi CA. The role of multi modality imaging in selecting patients and guiding lead placement for the delivery of cardiac resynchronization therapy. Expert Rev Cardiovasc Ther 2016; 15:93-107. [DOI: 10.1080/14779072.2016.1252674] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Jonathan M Behar
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | - Simon Claridge
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | - Tom Jackson
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | - Ben Sieniewicz
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | - Bradley Porter
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | - Jessica Webb
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | - Ronak Rajani
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| | | | | | - Christopher A Rinaldi
- Department of Imaging Sciences & Biomedical Engineering, King’s College London, London, UK
- Department of Cardiology, St. Thomas’ Hospital, London, UK
| |
Collapse
|