1
|
Dang S, Han D, Duan H, Jiang Y, Aihemaiti A, Yu N, Yu Y, Duan X. The value of T2-weighted MRI contrast ratio combined with DWI in evaluating the pathological grade of solid lung adenocarcinoma. Clin Radiol 2024; 79:279-286. [PMID: 38216369 DOI: 10.1016/j.crad.2023.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/30/2023] [Accepted: 12/09/2023] [Indexed: 01/14/2024]
Abstract
AIM To assess the predictive value of T2-weighted (T2W) magnetic resonance imaging (MRI) in combination with diffusion-weighted imaging (DWI) for determining the pathological grading of solid lung adenocarcinoma. MATERIALS AND METHODS The clinical and imaging data from 153 cases of solid lung adenocarcinoma (82 men, 71 women, mean age 63.2 years) confirmed at histopathology in The First Affiliated Hospital of Xi'an Jiaotong University from January 2017 to May 2022 were analysed retrospectively. Adenocarcinomas were classified into low-grade (G1 and G2) and high-grade (G3) groups following the 2020 pathological grading system proposed by the International Association for the Study of Lung Cancer. The T2-weighted contrast ratio (T2CR), calculated as the T2 signal intensity of the lung mass/nodule divided by the T2 signal intensity of the right rhomboid muscle was utilised. Two experienced radiologists reviewed the MRI images independently, measured the T2CR, and obtained apparent diffusion coefficient (ADC) values. The Mann-Whitney U-test was used to compare general characteristics (sex, age, maximum diameter), T2CR, and ADC values between the low-grade and high-grade groups. The non-parametric Kruskal-Wallis test determined differences in T2CR and ADC values among the five adenocarcinoma subtypes. Receiver characteristic curve (ROC) analysis, along with area under the curve (AUC) calculation, assessed the effectiveness of each parameter in distinguishing the pathological grade of lung adenocarcinoma. A Z-test was used to compare the AUC values. RESULTS Among the 153 patients with adenocarcinoma, 103 had low-grade adenocarcinoma, and 50 had high-grade adenocarcinoma. The agreement between T2CR and ADC observers was good (0.948 and 0.929, respectively). None of the parameters followed a normal distribution (p<0.05). The ADC value was lower in the high-grade adenocarcinoma group compared to the low-grade adenocarcinoma group (p=0.004), while the T2CR value was higher in the high-grade group (p=0.011). Statistically significant differences were observed in maximum diameter and gender between the two groups (p<0.001 and p=0.005, respectively), while no significant differences were noted in age (p=0.980). Among the five adenocarcinoma subtypes, only the lepidic and micropapillary subtypes displayed statistical differences in ADC values (p=0.047), with the remaining subtypes showing no statistical differences (p>0.05). The AUC values for distinguishing high-grade adenocarcinoma from low-grade adenocarcinoma were 0.645 for ADC and 0.627 for T2CR. Combining T2CR, ADC, sex, and maximum diameter resulted in an AUC of 0.778, sensitivity of 70%, and specificity of 75%. This combination significantly improved diagnostic efficiency compared to T2CR and ADC alone (p=0.008, z = 2.624; p=0.007, z = 2.679). CONCLUSION The MRI quantitative parameters are useful for distinguishing the pathological grades of solid lung adenocarcinoma, offering valuable insights for precise lung cancer treatment.
Collapse
Affiliation(s)
- S Dang
- The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shannxi 710061, China; Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - D Han
- The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shannxi 710061, China; Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - H Duan
- The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shannxi 710061, China; Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - Y Jiang
- Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - A Aihemaiti
- Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - N Yu
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang 712000, China; Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - Y Yu
- The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shannxi 710061, China; Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang 712000, China; Shaanxi University of Chinese Medicine, Xianyang 712000, China
| | - X Duan
- The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shannxi 710061, China.
| |
Collapse
|
2
|
Cavion CC, Altmayer S, Forte GC, Feijó Andrade RG, Hochhegger DQDR, Zaguini Francisco M, Camargo C, Patel P, Hochhegger B. Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis. Radiol Cardiothorac Imaging 2024; 6:e230241. [PMID: 38634743 PMCID: PMC11056753 DOI: 10.1148/ryct.230241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 02/18/2024] [Accepted: 03/07/2024] [Indexed: 04/19/2024]
Abstract
Purpose To perform a meta-analysis of the diagnostic performance of MRI for the detection of pulmonary nodules, with use of CT as the reference standard. Materials and Methods PubMed, Embase, Scopus, and other databases were systematically searched for studies published from January 2000 to March 2023 evaluating the performance of MRI for diagnosis of lung nodules measuring 4 mm or larger, with CT as reference. Studies including micronodules, nodules without size stratification, or those from which data for contingency tables could not be extracted were excluded. Primary outcomes were the per-lesion sensitivity of MRI and the rate of false-positive nodules per patient (FPP). Subgroup analysis by size and meta-regression with other covariates were performed. The study protocol was registered in the International Prospective Register of Systematic Reviews, or PROSPERO (no. CRD42023437509). Results Ten studies met inclusion criteria (1354 patients and 2062 CT-detected nodules). Overall, per-lesion sensitivity of MRI for nodules measuring 4 mm or larger was 87.7% (95% CI: 81.1, 92.2), while the FPP rate was 12.4% (95% CI: 7.0, 21.1). Subgroup analyses demonstrated that MRI sensitivity was 98.5% (95% CI: 90.4, 99.8) for nodules measuring at least 8-10 mm and 80.5% (95% CI: 71.5, 87.1) for nodules less than 8 mm. Conclusion MRI demonstrated a good overall performance for detection of pulmonary nodules measuring 4 mm or larger and almost equal performance to CT for nodules measuring at least 8-10 mm, with a low rate of FPP. Systematic review registry no. CRD42023437509 Keywords: Lung Nodule, Lung Cancer, Lung Cancer Screening, MRI, CT Supplemental material is available for this article. © RSNA, 2024.
Collapse
Affiliation(s)
- César Campagnolo Cavion
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Stephan Altmayer
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Gabriele Carra Forte
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Rubens Gabriel Feijó Andrade
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Daniela Quinto dos Reis Hochhegger
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Martina Zaguini Francisco
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Capitulino Camargo
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Pratik Patel
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| | - Bruno Hochhegger
- From the Department of Radiology, Pontifícia Universidade
Católica do Rio Grande do Sul, Av Ipiranga, 6681 – Partenon, Porto
Alegre, Rio Grande do Sul, Brazil, 90619-900 (C.C.C., G.C.F., R.G.F.A.);
Department of Radiology, Stanford University, Stanford, Calif (S.A.); Department
of Radiology, College of Medicine, University of Florida, Gainesville, Fla
(D.Q.d.R.H., P.P., B.H.); and Universidade Federal de Ciências da
Saúde de Porto Alegre, Porto Alegre, Brazil (M.Z.F., C.C.J.)
| |
Collapse
|
3
|
Sanchez F, Tyrrell PN, Cheung P, Heyn C, Graham S, Poon I, Ung Y, Louie A, Tsao M, Oikonomou A. Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo. Cancer Imaging 2023; 23:17. [PMID: 36793094 PMCID: PMC9933280 DOI: 10.1186/s40644-023-00531-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 02/04/2023] [Indexed: 02/17/2023] Open
Abstract
BACKGROUND Although MRI is a radiation-free imaging modality, it has historically been limited in lung imaging due to inherent technical restrictions. The aim of this study is to explore the performance of lung MRI in detecting solid and subsolid pulmonary nodules using T1 gradient-echo (GRE) (VIBE, Volumetric interpolated breath-hold examination), ultrashort time echo (UTE) and T2 Fast Spin Echo (HASTE, Half fourier Single-shot Turbo spin-Echo). METHODS Patients underwent a lung MRI in a 3 T scanner as part of a prospective research project. A baseline Chest CT was obtained as part of their standard of care. Nodules were identified and measured on the baseline CT and categorized according to their density (solid and subsolid) and size (> 4 mm/ ≤ 4 mm). Nodules seen on the baseline CT were classified as present or absent on the different MRI sequences by two thoracic radiologists independently. Interobserver agreement was determined using the simple Kappa coefficient. Paired differences were compared using nonparametric Mann-Whitney U tests. The McNemar test was used to evaluate paired differences in nodule detection between MRI sequences. RESULTS Thirty-six patients were prospectively enrolled. One hundred forty-nine nodules (100 solid/49 subsolid) with mean size 10.8 mm (SD = 9.4) were included in the analysis. There was substantial interobserver agreement (k = 0.7, p = 0.05). Detection for all nodules, solid and subsolid nodules was respectively; UTE: 71.8%/71.0%/73.5%; VIBE: 61.6%/65%/55.1%; HASTE 72.4%/72.2%/72.7%. Detection rate was higher for nodules > 4 mm in all groups: UTE 90.2%/93.4%/85.4%, VIBE 78.4%/88.5%/63.4%, HASTE 89.4%/93.8%/83.8%. Detection of lesions ≤4 mm was low for all sequences. UTE and HASTE performed significantly better than VIBE for detection of all nodules and subsolid nodules (diff = 18.4 and 17.6%, p = < 0.01 and p = 0.03, respectively). There was no significant difference between UTE and HASTE. There were no significant differences amongst MRI sequences for solid nodules. CONCLUSIONS Lung MRI shows adequate performance for the detection of solid and subsolid pulmonary nodules larger than 4 mm and can serve as a promising radiation-free alternative to CT.
Collapse
Affiliation(s)
- Felipe Sanchez
- grid.17063.330000 0001 2157 2938Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Pascal N. Tyrrell
- grid.17063.330000 0001 2157 2938Department of Medical Imaging, Department of Statistical Sciences, Institute of Medical Science, University of Toronto, 263 McCaul Street, Toronto, Ontario M5T 1WT Canada
| | - Patrick Cheung
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Chinthaka Heyn
- grid.17063.330000 0001 2157 2938Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Simon Graham
- grid.17063.330000 0001 2157 2938Physical Sciences Platform of Sunnybrook Research Institute, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Ian Poon
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Yee Ung
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Alexander Louie
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - May Tsao
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Anastasia Oikonomou
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario, M4N 3M5, Canada.
| |
Collapse
|
4
|
Application of deep learning-based super-resolution to T1-weighted postcontrast gradient echo imaging of the chest. LA RADIOLOGIA MEDICA 2023; 128:184-190. [PMID: 36609662 PMCID: PMC9938811 DOI: 10.1007/s11547-022-01587-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 12/30/2022] [Indexed: 01/09/2023]
Abstract
OBJECTIVES A deep learning-based super-resolution for postcontrast volume-interpolated breath-hold examination (VIBE) of the chest was investigated in this study. Aim was to improve image quality, noise, artifacts and diagnostic confidence without change of acquisition parameters. MATERIALS AND METHODS Fifty patients who received VIBE postcontrast imaging of the chest at 1.5 T were included in this retrospective study. After acquisition of the standard VIBE (VIBES), a novel deep learning-based algorithm and a denoising algorithm were applied, resulting in enhanced images (VIBEDL). Two radiologists qualitatively evaluated both datasets independently, rating sharpness of soft tissue, vessels, bronchial structures, lymph nodes, artifacts, cardiac motion artifacts, noise levels and overall diagnostic confidence, using a Likert scale ranging from 1 to 4. In the presence of lung lesions, the largest lesion was rated regarding sharpness and diagnostic confidence using the same Likert scale as mentioned above. Additionally, the largest diameter of the lesion was measured. RESULTS The sharpness of soft tissue, vessels, bronchial structures and lymph nodes as well as the diagnostic confidence, the extent of artifacts, the extent of cardiac motion artifacts and noise levels were rated superior in VIBEDL (all P < 0.001). There was no significant difference in the diameter or the localization of the largest lung lesion in VIBEDL compared to VIBES. Lesion sharpness as well as detectability was rated significantly better by both readers with VIBEDL (both P < 0.001). CONCLUSION The application of a novel deep learning-based super-resolution approach in T1-weighted VIBE postcontrast imaging resulted in an improvement in image quality, noise levels and diagnostic confidence as well as in a shortened acquisition time.
Collapse
|
5
|
Applying Compressed Sensing Volumetric Interpolated Breath-Hold Examination and Spiral Ultrashort Echo Time Sequences for Lung Nodule Detection in MRI. Diagnostics (Basel) 2021; 12:diagnostics12010093. [PMID: 35054260 PMCID: PMC8774698 DOI: 10.3390/diagnostics12010093] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/17/2021] [Accepted: 12/29/2021] [Indexed: 11/17/2022] Open
Abstract
This prospective study aimed to investigate the ability of spiral ultrashort echo time (UTE) and compressed sensing volumetric interpolated breath-hold examination (CS-VIBE) sequences in magnetic resonance imaging (MRI) compared to conventional VIBE and chest computed tomography (CT) in terms of image quality and small nodule detection. Patients with small lung nodules scheduled for video-assisted thoracoscopic surgery (VATS) for lung wedge resection were prospectively enrolled. Each patient underwent non-contrast chest CT and non-contrast MRI on the same day prior to thoracic surgery. The chest CT was performed to obtain a standard reference for nodule size, location, and morphology. The chest MRI included breath-hold conventional VIBE and CS-VIBE with scanning durations of 11 and 13 s, respectively, and free-breathing spiral UTE for 3.5–5 min. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normal structure visualizations were measured to evaluate MRI quality. Nodule detection sensitivity was evaluated on a lobe-by-lobe basis. Inter-reader and inter-modality reliability analyses were performed using the Cohen κ statistic and the nodule size comparison was performed using Bland–Altman plots. Among 96 pulmonary nodules requiring surgery, the average nodule diameter was 7.7 ± 3.9 mm (range: 4–20 mm); of the 73 resected nodules, most were invasive cancer (74%) or pre-invasive carcinoma in situ (15%). Both spiral UTE and CS-VIBE images achieved significantly higher overall image quality scores, SNRs, and CNRs than conventional VIBE. Spiral UTE (81%) and CS-VIBE (83%) achieved a higher lung nodule detection rate than conventional VIBE (53%). Specifically, the nodule detection rate for spiral UTE and CS-VIBE reached 95% and 100% for nodules >8 and >10 mm, respectively. A 90% detection rate was achieved for nodules of all sizes with a part-solid or solid morphology. Spiral UTE and CS-VIBE under-estimated the nodule size by 0.2 ± 1.4 mm with 95% limits of agreement from −2.6 to 2.9 mm and by 0.2 ± 1.7 mm with 95% limits of agreement from −3.3 to 3.5 mm, respectively, compared to the reference CT. In conclusion, chest CT remains the gold standard for lung nodule detection due to its high image resolutions. Both spiral UTE and CS-VIBE MRI could detect small lung nodules requiring surgery and could be considered a potential alternative to chest CT; however, their clinical application requires further investigation.
Collapse
|
6
|
Yu N, Duan H, Yang C, Yu Y, Dang S. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence for assessment of pulmonary lesions: a prospective comparison of CT and MRI. Cancer Imaging 2021; 21:68. [PMID: 34930463 PMCID: PMC8686653 DOI: 10.1186/s40644-021-00441-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 12/05/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose To determine whether the pulmonary MR imaging with free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence can detect lung lesions and display lesion profiles with an accuracy comparable to that of computed tomography (CT), which is the reference standard in this study. Population Sixty-three consecutive patients were prospectively enrolled between October, 2016 and March, 2017. All the patients received both 3T MRI scanning with a free-breathing r-VIBE sequence and chest standard CT. Morphologic features of lesions were evaluated by two radiologists with a 5-point system. Chest standard CT were used as reference standard. Weighted kappa analysis and chi-squared test were used to determine both inter-observer agreement and inter-method agreement. Results A total of 210 solid pulmonary nodules or masses and 1 ground-glass nodule were detected by CT. Compared to CT, r-VIBE correctly detected 95.7% of pulmonary nodules, including 100% of detection rate with diameter greater than 6 mm, 92.3% of pulmonary nodules with diameter between 4 and 6 mm, and 83.3% of pulmonary nodules with diameter less than 4 mm The inter-method agreements between r-VIBE and standard-dose CT were either “substantial” or “excellent” in the evaluation of following features of pulmonary nodules with diameter more than 10mm: including lobulation, spiculation, convergence of vessels, bubble-like attenuation, cavitation and mediastinal lymph node enlargement (0.605≤K≤1.000; P<0.0001). However, K values for inter-method agreements were significant but “moderate” or “poor” for evaluating pleural tag, halo, and calcification (0.355≤ K≤0.451; P<0.0001). Conclusion The use of pulmonary MR imaging with r-VIBE showed high detection rate of pulmonary nodules and inter-method agreement with CT. It is also useful for nodule morphologic assessment.
Collapse
Affiliation(s)
- Nan Yu
- Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, Xian Yang, China
| | - Haifeng Duan
- Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, Xian Yang, China
| | - Chuangbo Yang
- Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, Xian Yang, China
| | - Yong Yu
- Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, Xian Yang, China
| | - Shan Dang
- Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, Xian Yang, China. .,Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, -2# Weiyang Western Road, 712000, Xian Yang, China.
| |
Collapse
|
7
|
Olthof SC, Reinert C, Nikolaou K, Pfannenberg C, Gatidis S, Benkert T, Küstner T, Krumm P. Detection of lung lesions in breath-hold VIBE and free-breathing Spiral VIBE MRI compared to CT. Insights Imaging 2021; 12:175. [PMID: 34817715 PMCID: PMC8613318 DOI: 10.1186/s13244-021-01124-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 11/06/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Detection of pulmonary nodules in MRI requires fast imaging strategies without respiratory motion impairment, such as single-breath-hold Cartesian VIBE. As patients with pulmonary diseases have limited breath-hold capacities, this study investigates the clinical feasibility of non-Cartesian Spiral VIBE under free-breathing compared to CT as the gold standard. METHODS Prospective analysis of 27 oncological patients examined in PET/CT and PET/MR. A novel motion-robust 3D ultrashort-echo-time (UTE) MR sequence was evaluated in comparison with CT and conventional breath-hold MR. CT scans were performed under breath-hold in end-expiratory and end-inspiratory position (CT ex, CT in). MR data was acquired with non-contrast-enhanced breath-hold Cartesian VIBE followed by a free-breathing 3D UTE Spiral VIBE. Impact of respiratory motion on pulmonary evaluation was investigated by two readers in Cartesian VIBE, followed by UTE Spiral VIBE and CT ex and the reference standard of CT in. Diagnostic accuracy was calculated, and visual image quality assessed. RESULTS Higher detection rate and sensitivity of pulmonary nodules in free-breathing UTE Spiral VIBE in comparison with breath-hold Cartesian VIBE were found for lesions > 10 mm (UTE Spiral VIBE/VIBE/CT ex): 93%/54%/100%; Lesions 5-10 mm: 67%/25%/ 92%; Lesions < 5 mm: 11%/11%/78%. Lobe-based analysis revealed sensitivities and specificities of 64%/96%/41% and 96%/93%/100% for UTE Spiral VIBE/VIBE/CT ex. CONCLUSION Free-breathing UTE Spiral VIBE indicates higher sensitivity for detection of pulmonary nodules than breath-hold Cartesian VIBE and is a promising but time-consuming approach. However, sensitivity and specificity of inspiratory CT remain superior in comparison and should be preferred for detection of pulmonary lesions.
Collapse
Affiliation(s)
- Susann-Cathrin Olthof
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany
| | - Christian Reinert
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany
| | - Christina Pfannenberg
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany
| | - Sergios Gatidis
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany
| | - Thomas Benkert
- MR Applications Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen, Germany
| | - Thomas Küstner
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany.
| | - Patrick Krumm
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Straβe 3, 72076, Tuebingen, Germany
| |
Collapse
|
8
|
Feng H, Shi G, Liu H, Xu Q, Zhang N, Kuang J. Free-breathing radial volumetric interpolated breath-hold examination sequence and dynamic contrast-enhanced MRI combined with diffusion-weighted imaging for assessment of solitary pulmonary nodules. Magn Reson Imaging 2020; 75:100-106. [PMID: 33096226 DOI: 10.1016/j.mri.2020.10.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 09/27/2020] [Accepted: 10/18/2020] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To test the performance of free-breathing Dynamic Contrast-Enhanced MRI (DCE-MRI) using a radial volumetric interpolated breath-hold examination (VIBE) sequence combined with diffusion-weighted imaging (DWI) for quantitative solitary pulmonary nodule (SPN) assessment. METHODS A total of 67 SPN cases receiving routine MRI routine scans, DWI, and dynamic-enhanced MRI in our hospital from May 2017 to November 2018 were collected. These cases were divided into a malignant group and a benign group according to the characteristics of the SPNs. The quantitative DCE-MRI parameters (Ktrans, Kep, Ve) and apparent diffusion coefficient (ADC) values of the nodules were measured. RESULTS The Ktrans and Kep values in the malignant group were higher than those in the benign group, while the ADC values in the malignant group were lower than those in the benign group. Furthermore, the Ktrans value of adenocarcinoma was higher than that of squamous cell carcinoma and small cell carcinoma (P < 0.05). The Ve value was significantly different between non-small cell carcinoma and small cell carcinoma (P < 0.05). With an ADC value of 0.98 × 10-3 mm2/s as the threshold, the specificity and sensitivity to diagnose benign and malignant nodules was 90.6% and 80%, respectively. CONCLUSION High-temporal-resolution DCE-MRI using the r-VIBE technique in combination with DWI could contribute to pulmonary nodule analysis and possibly serve as a potential alternative to distinguish malignant from benign nodules as well as differentiate different types of malignancies.
Collapse
Affiliation(s)
- Hui Feng
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
| | - Gaofeng Shi
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China.
| | - Hui Liu
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
| | - Qian Xu
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
| | - Ning Zhang
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
| | - Jie Kuang
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, China
| |
Collapse
|