1
|
Xu L, Zhang Y, Jin S, Luo S, Chen K, Fang S, Zhong L, Zhang J, He R. Novel lignin α-O-4 derived hydrogen donors in CQ-based photoinitiating systems for dental resins. Sci Rep 2024; 14:16719. [PMID: 39030243 PMCID: PMC11271577 DOI: 10.1038/s41598-024-67377-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 07/10/2024] [Indexed: 07/21/2024] Open
Abstract
The purpose of this work is to explore the properties of the lignin-derived amine-free photoinitiating systems (PISs) during the curing process. Four novel hydrogen donors (HD1, HD2, HD3, and HD4) derived from lignin α-O-4 structural were designed and synthesized by simple methods, and their low C-H bond dissociation energies on methylene were determined by molecular orbitals theory. Four experimental groups using CQ (camphorquinone)/HD PIs formulated with Bis-GMA/TEGDMA (70 w%/30 w%) were compared to CQ/EDB (ethyl 4-dimethylamino benzoate) system. The photopolymerization profiles and double bond conversion rate was tracked by FTIR experiments; the color bleaching ability of the samples and color aging test assay were performed using color indexes measurements; The cytotoxicity of the samples was also compared to EDB related systems. All of the experimental groups with new HDs were compared to the control group with EDB by statistical analysis. Compared to CQ/EDB system, new lignin-derived hydrogen donors combined with CQ showed comparable or even better performances in polymerization initiation to form resin samples, under a blue dental LED in air. Excellent color bleaching property was observed with the new HDs. Aging tests and cytotoxicity examination of the resin were performed, indicating the new lignin compounds to be efficient hydrogen donors for amine-free CQ-based photo-initiating system. Novel lignin α-O-4 derived hydrogen donors are promising for further usage in light-curing materials.
Collapse
Affiliation(s)
- Lixia Xu
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- The 3rd People's Hospital of Deqing, Huzhou, Zhejiang, China
| | - Ying Zhang
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Shuqi Jin
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Shuxin Luo
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- Zhejiang Provincial Hospital of Chinese Medicine, Hangzhou, Zhejiang, China
| | - Kailun Chen
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Sheng Fang
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Liangjun Zhong
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Jian Zhang
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, Hangzhou, Zhejiang, China
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Rui He
- Center of Stomatology, The Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China.
| |
Collapse
|
2
|
Castro-Ramirez L, Espinoza-Salcedo M, Huamani-Echaccaya J, Ladera-Castañeda M, Cervantes-Ganoza L, Hernández-Huamaní E, Aroste-Andía R, Gavilán-Chávez P, Cayo-Rojas C. Effect of Polywave and Monowave Light Curing Units on the Microtensile Bond Strength and Failure Types of Different Bulk-Fill Resin Composites: An in vitro Study. Clin Cosmet Investig Dent 2024; 16:153-165. [PMID: 38808075 PMCID: PMC11131952 DOI: 10.2147/ccide.s465226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 05/17/2024] [Indexed: 05/30/2024] Open
Abstract
Aim This study aimed to evaluate the effects of polywave and monowave light-emitting diode curing units on the microtensile bond strength and failure types of three bulk-fill resin composites. Materials and Methods This in vitro experimental study was performed on 180 microbars obtained from human third molars and were distributed into 12 groups according to the type of bulk-fill resin composite and the light-curing unit. Third molars were restored using Filtek One Bulk Fill Restorative, Tetric® N-Ceram Bulk Fill, and Opus Bulk Fill resin composites was light-cured with Elipar Deep Cure L and Valo in three modes: standard, high power, and extra power. Subsequently, microtensile analysis was carried out with a universal testing machine and the type of failure with an optical stereomicroscope. For statistical analysis, the Kruskal-Wallis H-test was used, with the Bonferroni post hoc test and Fisher's exact test, considering a significance of p<0.05. Results There were significant differences in the microtensile bond strength between the Filtek One Bulk Fill restorative and Opus Bulk-Fill (p = 0.042) when light was cured with the polywave unit at standard power. On the other hand, the Filtek One Bulk Fill Restorative and Opus Bulk Fill resins showed significant differences in microtensile bond strength when light was cured with the monowave unit compared with the polywave unit (p<0.05). Conclusion The presence of alternative photoinitiator systems that are more reactive than camphorquinone produced higher microtensile bond strength in Tetric N-Ceram Bulk Fill and Opus Bulk Fill resins when light-cured with a high and standard polywave unit, respectively, compared to Filtek One Bulk Fill resins. Finally, Tetric N-Ceram Bulk Fill and Opus Bulk Fill resins had the highest percentage of mixed failures, while Filtek One Bulk Fill resin had adhesive failures, which was related to its lower microtensile bond strength.
Collapse
Affiliation(s)
- Leonor Castro-Ramirez
- Postgraduate School, Universidad Privada Antenor Orrego, Trujillo, Peru
- School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru
| | | | | | - Marysela Ladera-Castañeda
- Faculty of Dentistry and Postgraduate School, Research Team “Salud Pública – Salud Integral”, Universidad Nacional Federico Villarreal, Lima, Peru
| | | | | | - Rosa Aroste-Andía
- School of Stomatology, Universidad Privada San Juan Bautista, Ica, Peru
| | | | - César Cayo-Rojas
- School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru
| |
Collapse
|
3
|
Odabaş T, Harorlı OT. Dental restorative materials and halitosis: a preliminary in-vitrostudy. J Breath Res 2024; 18:036005. [PMID: 38744271 DOI: 10.1088/1752-7163/ad4b57] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 05/14/2024] [Indexed: 05/16/2024]
Abstract
Despite the widespread use of dental restorative materials, little information exists in the literature regarding their potential impact on bad breath. This in vitro study aims to fill this gap by investigating the influence of different restorative materials on the release of hydrogen sulfide (H2S). Thirteen diverse dental restorative materials, including composites, flowable composites, glass ionomer restorative materials, high-copper amalgam, and CAD-CAM blocks, were examined. Cellulose Sponge models were used as negative and positive control. All samples were prepared with a diameter of 5 mm and a height of 2 mm. Except for the negative control group, all samples were embedded into Allium cepa L., and the emitted H2S was measured using the Wintact W8802 hydrogen sulfide monitor. Surface roughness's effect on emission was explored by roughening the surfaces of CAD-CAM material samples, and gas emission was measured again. The data were statistically analyzed using the Kruskal-Wallis test and DSCF pairwise comparison tests. Fiber-reinforced flowable composite (EverX Flow), amalgam (Nova 70-caps), and certain composite materials (IPS Empress Direct, Tetric Evoceram, Admira Fusion X-tra) released higher H2S concentrations compared to the negative control. The H2S release period lasted longer in the same materials mentioned above, along with G-aenial Universal Injectable. Indirectly used materials, such as GC Cerasmart, Vita Enamic, and Vita YZ HT, demonstrated significantly lower emissions compared to other direct restoratives. Importantly, the surface roughness of indirect materials did not significantly affect peak H2S concentrations or release times. The study reveals variations in H2S release among restorative materials, suggesting potential advantages of indirect restorative materials in reducing H2S-induced halitosis. This comprehensive understanding of the relationship between restorative materials and halitosis can empower both dental professionals and patients to make well-informed treatment choices. Notably, there is evidence supporting the enhanced performance of indirect restorative materials for individuals affected by halitosis.
Collapse
Affiliation(s)
- Tuğçe Odabaş
- Department of Restorative Dentistry Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| | - Osman Tolga Harorlı
- Department of Restorative Dentistry Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| |
Collapse
|
4
|
D’Arcangelo C, Buonvivere M, De Angelis F. Anterior Esthetic Restorations with the Stratified Stamp Technique: A Case Report. Biomimetics (Basel) 2024; 9:299. [PMID: 38786510 PMCID: PMC11117549 DOI: 10.3390/biomimetics9050299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/08/2024] [Accepted: 05/16/2024] [Indexed: 05/25/2024] Open
Abstract
Anterior teeth restoration represents a challenge for dentists, who often rely on the dental technician's wax-up. The proposed Stratified Stamp Technique (SST) allows for clinically reproducing the wax-up in a quick and easy way. A patient with fractures and discoloration on the upper central incisors was treated with resin-based composite direct restorations. Using SST, a 1 mm thick thermoformed polyethylene-terephthalate-glycol (PETG) template, based on the technician's wax-up, was produced. Enamel Selective Area Reduction (SAR) was performed to guarantee adequate space for the restorations, and the fracture margins were rounded and finished. Traditional layering procedures according to the five color dimensions of teeth were performed, except for the final labial layer, which was realized with warm composite loaded inside the template and polymerized through it, in order to ensure accurate tooth morphology reproduction. SST offers a reliable method for transferring technician's wax-up morphology to direct composite restorations in anterior teeth. Compared with other methods, SST allows for better isolation with a rubber dam and permits traditional layering with multiple composite shades, thus leading to satisfactory esthetic outcomes.
Collapse
Affiliation(s)
| | | | - Francesco De Angelis
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University Chieti-Pescara, 66100 Chieti, Italy; (C.D.); (M.B.)
| |
Collapse
|
5
|
Santander-Rengifo F, Carreras-Presas CM, Aroste-Andía R, Hernández-Huamaní E, Gavilán-Chávez P, Cervantes-Ganoza L, Cayo-Rojas C. Microtensile Bond Strength and Failure Mode of Different Universal Adhesives on Human Dentin. Int Dent J 2024:S0020-6539(24)00114-X. [PMID: 38734514 DOI: 10.1016/j.identj.2024.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/13/2024] [Accepted: 04/05/2024] [Indexed: 05/13/2024] Open
Abstract
AIM The aim of this study was to compare the microtensile bond strength (µTBS) and failure mode of 4 different universal adhesive systems (UAs) on human dentin. MATERIALS AND METHODS The study sectioned the occlusal thirds of 32 human third molars and divided them into 4 groups based on the adhesive system used. Group A: Palfique Universal Bond, Group B: Single Bond Universal, Group C: All-Bond Universal, and Group D: One Coat 7 Universal. The specimens underwent a 10,000-cycle thermocycling ageing process prior to testing (n = 32). Afterwards, 8 beams were obtained per group and subjected to µTBS testing using a digital universal testing machine at a speed of 1 mm/min. The microtensile bond strength values were analysed in Megapascals (MPa), and the failure mode was evaluated using a stereomicroscope. Welch's parametric ANOVA with robust variance and the Games-Howell post hoc test were used for µTBS comparisons, and Fisher's exact test was used to determine the association between adhesive type and failure mode. The significance level was set at P < .05. RESULTS Group D showed a significantly higher µTBS than groups A (P < .001) and B (P < .001), but no significant difference was observed with group C (P= .075). Furthermore, groups B and C showed significantly higher µTBS than group A (P< .001 and P < .001, respectively), but there was no significant difference between groups B and C (P = .132). Additionally, group A exhibited a significant association with an adhesive failure mode (P < .05), whereas groups B, C, and D were significantly associated with a mixed failure mode (P < .05). CONCLUSION The One Coat 7 Universal adhesive system showed higher microtensile bond strength values and higher chemical interaction with dentin compared to Palfique Universal Bond and Single Bond Universal. However, no significant differences were observed compared to All-Bond Universal.
Collapse
Affiliation(s)
- Flor Santander-Rengifo
- Doctoral Program and Health Sciences, Doctoral and Research School, Universidad Europea de Madrid, Madrid, Spain; Academic Program of Dentistry, Universidad Peruana de Ciencias Aplicadas, Lima, Peru
| | - Carmen Martin Carreras-Presas
- Head of Esthetic Dentistry Program, Faculty of Health and Biomedical Sciences, Dentistry Department, Universidad Europea de Madrid, Madrid, Spain
| | - Rosa Aroste-Andía
- School of Stomatology, Universidad Privada San Juan Bautista, Ica, Peru
| | | | | | | | - César Cayo-Rojas
- School of Stomatology, Universidad Privada San Juan Bautista, Ica, Peru.
| |
Collapse
|
6
|
Alarcón-Torres SG, Chávez-Méndez MA. [Surface roughness of two composite resins after immersion in soda drinks: in vitro study]. REVISTA CIENTÍFICA ODONTOLÓGICA 2024; 12:e185. [PMID: 39015313 PMCID: PMC11247465 DOI: 10.21142/2523-2754-1201-2024-185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 03/13/2024] [Indexed: 07/18/2024] Open
Abstract
Objective Compare the surface roughness of two composite resins after immersion in carbonated beverages. Materials and methods 160 resin discs (6 x 2 mm) were divided into 8 groups (n=20 per group) according to type of resin (Filtek™ Z350 XT® and Palfique LX5®) and type of immersion in beverages (distilled water, Coca Cola®, Inca Kola® and Kola Escocesa®. The immersions were carried out under a structured cycle: 4 immersions a day for 5 days, intermediate storage in distilled water and overnight incubation for 8 h at 37°C. The measurements with the roughness meter were evaluated in three times: baseline, 7 and 14 days. The three-way Anova test was used at P<0.05. Results Roughness showed differences only for the individual factors of time (P<0.000) and resin (P=0.000), and for the interaction time*drink (P=0.000) and resin*drink (P=0.003). Roughness was higher with Filtek Z350 XT® immersed with Inca Kola® (0.85 ± 0.37) than 14 days compared to other times (P=0.035) and with Palfique LX5 immersed in Coca Cola® at 7 days (1.61 ± 0.42) and in Inca Kola® at 14 days (1.66 ± 0.56) compared to distilled water (P<0,05). Conclusion Surface roughness was affected by the type of resin, the type of soft drink and the immersion time. The roughness was greater with the Palfique LX5® nanohybrid resin, the Inca Kola® drink and after 14 days of immersion.
Collapse
Affiliation(s)
- Sharon Gianella Alarcón-Torres
- Carrera de Estomatologia, Universidad Cientifica del Sur. Lima Peru. , Universidad Científica del Sur Carrera de Estomatologia Universidad Cientifica del Sur Lima Peru
| | - Martín Andrés Chávez-Méndez
- Carrera de Estomatologia, Universidad Cientifica del Sur. Lima Peru. , Universidad Científica del Sur Carrera de Estomatologia Universidad Cientifica del Sur Lima Peru
| |
Collapse
|
7
|
Allccahuaman-Avalos R, Medina-Sánchez R, Castro-Ramirez L, Ladera-Castañeda M, Cervantes-Ganoza L, Martínez-Campos R, Solís-Dante F, Aliaga-Mariñas A, Verástegui-Sandoval A, Cayo-Rojas C. In Vitro Color Stability Evaluation of Three Polished and Unpolished Nanohybrid Resin Composites Immersed in a 0.12% Chlorhexidine-Based Mouthwash at Different Times. Polymers (Basel) 2023; 15:polym15061339. [PMID: 36987120 PMCID: PMC10055837 DOI: 10.3390/polym15061339] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 02/26/2023] [Accepted: 03/02/2023] [Indexed: 03/12/2023] Open
Abstract
The use of chlorhexidine-based mouthwashes on resin composites with rough surfaces can cause discoloration which compromises the esthetic of patients. The present study aimed to evaluate the in vitro color stability of Forma (Ultradent Products, Inc., South Jordan), Tetric N-Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Z350XT (3M, ESPE, St. Paul, MN, USA) resin composites, with and without polishing, after being immersed in a 0.12% chlorhexidine (CHX)-based mouthwash at different times. The present in vitro experimental and longitudinal study used 96 nanohybrid resin composite blocks (Forma, Tetric N-Ceram and Filtek Z350XT) 8 mm in diameter and 2 mm thick, evenly distributed. Each resin composite group was divided into two subgroups (n = 16) with and without polishing and then immersed in a 0.12% CHX-based mouthwash for 7, 14, 21 and 28 days. Color measurements were performed with a calibrated digital spectrophotometer. Nonparametric tests were used to compare independent (Mann–Whitney U and Kruskal–Wallis) and related (Friedman) measures. In addition, the Bonferroni post hoc correction was used considering a significance level of p < 0.05. All polished and unpolished resin composites presented color variation < 3.3 when immersed for up to 14 days in 0.12% CHX-based mouthwash. The polished resin composite with the lowest color variation (ΔE) values over time was Forma, and the one with the highest values was Tetric N-Ceram. When comparing the color variation (ΔE) over time, it was observed that the three resin composites, with and without polishing, presented a significant change (p < 0.001), although these changes in color variation (ΔE) were evident from 14 days between each color acquisition (p < 0.05). The unpolished Forma and Filtek Z350XT resin composites showed significantly more color variation than the same polished ones at all times when immersed in a 0.12% CHX-based mouthwash for 30 s daily. In addition, every 14 days, all three resin composites with and without polishing showed a significant color change, while, every 7 days, color stability was maintained. All the resin composites showed clinically acceptable color stability when exposed for up to 14 days to the above-mentioned mouthwash.
Collapse
Affiliation(s)
| | | | | | - Marysela Ladera-Castañeda
- Research Team “Salud Pública—Salud Integral”, Faculty of Dentistry, Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | | | - Reynaldo Martínez-Campos
- Oral Rehabilitation Department, School of Stomatology, Universidad Científica del Sur, Lima 15067, Peru
| | | | - Ana Aliaga-Mariñas
- Research Team “Salud Pública—Salud Integral”, Faculty of Dentistry, Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | - Arturo Verástegui-Sandoval
- Faculty of Health Sciences, Professional Academic School of Dentistry, Universidad Privada Norbert Wiener, Lima 15046, Peru
| | - César Cayo-Rojas
- School of Stomatology, Universidad Privada San Juan Bautista, Lima 15067, Peru
- Correspondence:
| |
Collapse
|
8
|
López-Torres J, Hernández-Caba K, Cervantes-Ganoza L, Ladera-Castañeda M, Martínez-Campos R, Solís-Dante F, Briceño-Vergel G, Cayo-Rojas C. Microleakage of Class II Bulk-Fill Resin Composite Restorations Cured with Light-Emitting Diode versus Quartz Tungsten-Halogen Light: An In Vitro Study in Human Teeth. Biomedicines 2023; 11:biomedicines11020556. [PMID: 36831092 PMCID: PMC9953121 DOI: 10.3390/biomedicines11020556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 01/28/2023] [Accepted: 02/08/2023] [Indexed: 02/17/2023] Open
Abstract
Background: Resin composites undergo a certain degree of shrinkage when light-cured with different light sources available on the market, resulting in microleakage of dental restorations. The aim of the present study was to assess microleakage of class II restorations with bulk-fill resin composites cured with LED (light-emitting diode) and QTH (quartz tungsten-halogen light) units, both in cervical and occlusal areas of cavity preparations. Materials and Methods: In the present in vitro experimental study, a total of 30 human molar teeth were used, in which 60 class II cavities were prepared (mesial and distal) and restored with Filtek bulk fill resin composite. Restorations were equally distributed in 3 groups according to type of curing light: A, QTH (Litex 680A Dentamerica®); B, LED (Bluephase N® 3rd generation); and C, LED (Valo® 3rd generation). Each group was further subdivided into subgroups 1 and 2 according to IV-A or IV-B resin composite color. Restored teeth were subjected to 20,000 thermal cycles between 5° and 55 °C, then immersed in 1M silver nitrate solution for 24 h. Subsequently, the teeth were sectioned mesiodistally to obtain samples for observation under stereomicroscope in order to determine microleakage degree. Kruskal-Wallis H and Mann-Whitney U statistical tests were applied with a significance level of 5% (p < 0.05). Results: No statistically significant differences were found in the degree of microleakage of bulk-fill resin composites light-cured with LED and QTH units for both occlusal (p > 0.05) and cervical areas (p > 0.05). Additionally, no significant differences were found when comparing microleakage between occlusal and cervical areas (p > 0.05), regardless of lamp type. In addition, significant differences in microleakage degree were found between bulk-fill resins with IV-A and IV-B shades when they were light-cured with QTH at cervical level (p = 0.023). However, there were no significant differences when comparing these bulk-fill resin composite shades at occlusal level with LED (p > 0.05) and QTH (p > 0.05) units. Conclusions: Class II restorations with bulk-fill resin composite in IV-A and IV-B shades light-cured with third generation LED lamp and QTH showed no significant differences in microleakage when compared in both occlusal and cervical areas. On the other hand, significantly more microleakage was found at the cervical level when a darker shade of resin composite was used and light-cured with the QTH unit.
Collapse
Affiliation(s)
- Jenny López-Torres
- School of Stomatology, Universidad Privada San Juan Bautista, Lima 15067, Peru
| | - Karen Hernández-Caba
- Research Team “Salud Pública—Salud Integral”, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | | | - Marysela Ladera-Castañeda
- Research Team “Salud Pública—Salud Integral”, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | - Reynaldo Martínez-Campos
- Oral Rehabilitation Department, School of Stomatology, Universidad Científica del Sur, Lima 15067, Peru
| | | | | | - César Cayo-Rojas
- School of Stomatology, Universidad Privada San Juan Bautista, Lima 15067, Peru
- Correspondence:
| |
Collapse
|
9
|
Delikan E, Erturk-Avunduk AT, Karatas O, Saçmacı Ş. Effect of topical fluoride applications on residual monomer release from resin-based restorative materials. BMC Oral Health 2023; 23:1. [PMID: 36593449 PMCID: PMC9808933 DOI: 10.1186/s12903-022-02698-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 12/26/2022] [Indexed: 01/03/2023] Open
Abstract
BACKGROUND The effects of topical fluoride applications on the release of monomer ingredients from resin-based dental materials by immersion in various extraction solutions are unclear. The aim of this study was to determine the effect of topical fluorides (APF and NaF) on the elution of residual monomers (Bis-GMA, TEGDMA, UDMA, and HEMA) from resin-based materials. METHODS Ninety specimens were prepared, 30 bulk-fill composite resin, 30 nanohybrid universal composite resin, and 30 polyacid-modified composite resin (compomer). These were randomly divided into three groups based on fluoride application procedures. Each specimen was kept in 75% ethanol solution, and residual monomers released from materials were analyzed using high-performance liquid chromatography (HPLC) after 10 min, 1 h, 24 h, and 30 days. The groups were compared using the Mann Whitney U and Kruskal Wallis tests. Measurements were analyzed using the Friedman and Wilcoxon signed-rank tests. RESULTS Fluoride applications generally had no considerable effect on the amount of residual monomer released from resin-based restorative materials. The amount of monomer release after topical APF application was similar to the release in the control group and was lower than the release in the NaF group. The release of monomers from the resin-based material used in the study did not approach toxic levels at the applied time intervals. The compomer released lower amounts of monomer than other resin-based materials. CONCLUSIONS Fluoride applications do not increase monomer release from resin-based restorative materials. However, compomers should be employed by clinicians due to their lower monomer release compared to other resin restorative materials. The release of monomers from all the resin-based materials did not approach toxic levels at the applied time intervals.
Collapse
Affiliation(s)
- Ebru Delikan
- grid.466101.40000 0004 0471 9784Department of Pediatric Dentistry, Faculty of Dentistry, Nuh Naci Yazgan University, TR-38170 Kayseri, Türkiye
| | - Ayse Tugba Erturk-Avunduk
- grid.411691.a0000 0001 0694 8546Department of Restorative Dentistry, Faculty of Dentistry, Mersin University, TR-33343 Mersin, Türkiye
| | - Ozcan Karatas
- grid.466101.40000 0004 0471 9784Department of Restorative Dentistry, Faculty of Dentistry, Nuh Naci Yazgan University, TR-38170 Kayseri, Türkiye
| | - Şerife Saçmacı
- grid.411739.90000 0001 2331 2603Department of Chemistry, Faculty of Sciences, Erciyes University, TR-38039 Kayseri, Türkiye
| |
Collapse
|
10
|
Zamudio-Santiago J, Ladera-Castañeda M, Santander-Rengifo F, López-Gurreonero C, Cornejo-Pinto A, Echavarría-Gálvez A, Cervantes-Ganoza L, Cayo-Rojas C. Effect of 16% Carbamide Peroxide and Activated-Charcoal-Based Whitening Toothpaste on Enamel Surface Roughness in Bovine Teeth: An In Vitro Study. Biomedicines 2022; 11:biomedicines11010022. [PMID: 36672530 PMCID: PMC9856117 DOI: 10.3390/biomedicines11010022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/18/2022] [Accepted: 12/19/2022] [Indexed: 12/25/2022] Open
Abstract
Background: Activated charcoal is a nanocrystalline form of carbon with a large specific surface area and high porosity in the nanometer range, having consequently the capacity to absorb pigments, chromophores, and stains responsible for tooth color change, while carbamide peroxide is unstable and breaks down immediately upon contact with tissue and saliva, first dissociating into hydrogen peroxide and urea and subsequently into oxygen, water, and carbon dioxide. Therefore, the aim of the present study was to assess the effect of 16% carbamide peroxide and activated-charcoal-based whitening toothpaste on enamel surface roughness in bovine teeth. Materials and Methods: The present experimental in vitro, longitudinal, and prospective study consisted of 60 teeth randomly distributed in six groups: A: artificial saliva, B: conventional toothpaste (Colgate Maximum Protection), C: whitening toothpaste with activated charcoal (Oral-B 3D White Mineral Clear), D: 16% carbamide peroxide (Whiteness Perfect 16%), E: 16% carbamide peroxide plus conventional toothpaste (Whiteness Perfect 16% plus Colgate Maximum Protection), and F: 16% carbamide peroxide plus whitening toothpaste with activated charcoal (Whiteness Perfect 16% plus Oral-B 3D White Mineral Clear). Surface roughness was assessed with a digital roughness meter before and after each treatment. For the statistical analysis, Student’s t test for related samples was used, in addition to the ANOVA test for one intergroup factor, considering a significance level of p < 0.05. Results: The surface roughness variation of bovine tooth enamel, before and after application of bleaching agent, was higher in groups of whitening toothpaste with activated charcoal (0.200 µm, Confidence Interval (CI): 0.105; 0.296 µm) and 16% carbamide peroxide plus whitening toothpaste with activated charcoal (0.201 µm, (CI): 0.092; 0.309 µm). In addition, bovine teeth treated with conventional toothpaste (p = 0.041), whitening toothpaste with activated charcoal (p = 0.001), and 16% carbamide peroxide plus whitening toothpaste with activated charcoal (p = 0.002) significantly increased their surface roughness values. On the other hand, significant differences were observed when comparing the variation in surface roughness between the application of artificial saliva (control) and the whitening toothpaste with activated charcoal (p = 0.031), and the 16% carbamide peroxide plus whitening toothpaste with activated charcoal (p = 0.030). Conclusion: The use of whitening toothpaste with activated charcoal and in combination with 16% carbamide peroxide significantly increased enamel surface roughness in bovine teeth.
Collapse
Affiliation(s)
- Jorge Zamudio-Santiago
- Grupo de Investigación Salud y Bienestar Global, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | - Marysela Ladera-Castañeda
- Grupo de Investigación Salud y Bienestar Global, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | - Flor Santander-Rengifo
- Academic Program of Dentistry, Universidad Peruana de Ciencias Aplicadas, Lima 15023, Peru
| | | | - Alberto Cornejo-Pinto
- Grupo de Investigación Salud y Bienestar Global, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | | | | | - César Cayo-Rojas
- Grupo de Investigación Salud y Bienestar Global, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
- School of Stomatology, Universidad Privada San Juan Bautista, Lima 15067, Peru
- Correspondence:
| |
Collapse
|
11
|
Influence of Air-Barrier and Curing Light Distance on Conversion and Micro-Hardness of Dental Polymeric Materials. Polymers (Basel) 2022; 14:polym14245346. [PMID: 36559715 PMCID: PMC9785261 DOI: 10.3390/polym14245346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 11/24/2022] [Accepted: 12/03/2022] [Indexed: 12/12/2022] Open
Abstract
This study aims to assess the conversion degree and hardness behavior of two new commercial dental restorative composites that have been submitted to light curing in different environments (air and glycerin, respectively) at various distances from the light source (1 to 5 mm) and to better understand the influence of the preparation conditions of the restorative materials. Through FT-IR spectrometry, the crosslinking degree of the commercial restorative materials have been investigated and different conversion values were obtained (from ~17% to ~90%) but more importantly, it was shown that the polymerization environment exhibits a significant influence on the crosslinking degree of the resin-based composites especially for obtaining degrees of higher polymerization. Additionally, the mechanical properties of the restorative materials were studied using the nanoindentation technique showing that the nano-hardness behavior is strongly influenced not only by the polymerization lamp position, but also by the chemical structure of the materials and polymerization conditions. Thus, the nanoindentation results showed that the highest nano-hardness values (~0.86 GPa) were obtained in the case of the flowable C3 composite that contains BisEMA and UDMA as a polymerizable organic matrix when crosslinked at 1 mm distance from the curing lamp using glycerin as an oxygen-inhibitor layer.
Collapse
|
12
|
Berto-Inga J, Santander-Rengifo F, Ladera-Castañeda M, López-Gurreonero C, Castro Pérez-Vargas A, Cornejo-Pinto A, Cervantes-Ganoza L, Cayo-Rojas C. Surface Microhardness of Bulk-Fill Resin Composites Handled With Gloves. Int Dent J 2022:S0020-6539(22)00231-3. [DOI: 10.1016/j.identj.2022.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 10/14/2022] [Accepted: 10/14/2022] [Indexed: 11/19/2022] Open
|
13
|
Erturk-Avunduk AT, Cengiz-Yanardag E, Karakaya I. The effect of bleaching applications on stained bulk-fill resin composites. BMC Oral Health 2022; 22:392. [PMID: 36088325 PMCID: PMC9464385 DOI: 10.1186/s12903-022-02414-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 08/29/2022] [Indexed: 08/26/2023] Open
Abstract
Background The structure of bulk-fill resin composites differs from that of their conventional counterparts, but how this difference affects the color stability of the former after staining and bleaching is unclear. Accordingly, this study was aimed at investigating color change in nine bulk-fill resin composites and one nanohybrid resin composite treated with hydrogen peroxide and carbamide peroxide after staining with tea, coffee, and red wine. Methods Eighty specimens were prepared from each resins [Clearfil Majesty Posterior (CMP), SDR flow+ (SDR), FiltekTMBulk-Fill Flowable Restorative (FBF), Reveal HD Bulk (RHD), Beautifil-Bulk Restorative (BBR), Tetric EvoCeram® Bulk Fill (TEC), SonicFill™2 (SF2), everX Posterior™ (eXP), X-tra base (XB), and Venus® Bulk Fill (VBF)]. Following baseline color measurements, the specimens were randomly divided into 4 groups according to immersion solutions and distilled water as the control. At the end of a 30-day test period, color measurements were repeated, and color change values (∆E00) were calculated. Each resin group was then divided into 2 subgroups (with 10 specimens per group) on the basis of bleaching agent (Opalescence Boost 40%, Opalescence PF 16%). Following bleaching application, ∆E00 and changes of whiteness (∆WID1 = WIDbleaching-WIDbaseline, ΔWID2 = WIDbleaching-WIDstaining) values were recorded. Two- and three-way analyses of variance and Tukey’s post hoc test were performed, with a P < 0.05 regarded as indicative of significance. Results After immersion in distilled water, tea, and red wine, the highest ΔE00 values were observed in eXP (P < 0.05). Resin materials immersed in coffee and tea exhibited statistically higher ∆E00 values than those immersed in red wine except for eXP, TEC, and FBF (P < 0.05). For eXP, the highest ∆E00 values were recorded in distilled water. For TEC and FBF, there was no statistically significant difference among the immersion solutions and distilled water (P > 0.05). For all the resins and staining beverages, no statistically significant difference in ∆WID1 and ∆WID2 values were detected between bleaching agents (P > 0.05). All the ΔWID1 values were above the whiteness perceptibility threshold. Conclusion The bulk-fill materials were more resistant to discoloration and bleaching procedures than the conventional resin composites. Coffee and tea caused more staining than distilled water and red wine generally. The type of bleaching procedure had no effect on the whiteness of the tested materials.
Collapse
|
14
|
Carrillo-Marcos A, Salazar-Correa G, Castro-Ramirez L, Ladera-Castañeda M, López-Gurreonero C, Cachay-Criado H, Aliaga-Mariñas A, Cornejo-Pinto A, Cervantes-Ganoza L, Cayo-Rojas CF. The Microhardness and Surface Roughness Assessment of Bulk-Fill Resin Composites Treated with and without the Application of an Oxygen-Inhibited Layer and a Polishing System: An In Vitro Study. Polymers (Basel) 2022; 14:polym14153053. [PMID: 35956567 PMCID: PMC9370367 DOI: 10.3390/polym14153053] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 07/16/2022] [Accepted: 07/25/2022] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to assess the microhardness and surface roughness of bulk-fill resin composites treated with and without the application of an oxygen-inhibited layer (OIL) and a polishing system. This in vitro experimental study consisted of 72 resin composite blocks divided into three groups: Tetric N-Ceram Bulk Fill, Opus Bulk Fill APS, and Filtek Bulk Fill. Each resin composite group was further divided into two subgroups: with and without OIL control. Subsequently, surface roughness and microhardness were measured before and after polishing. A t-test was used to compare independent and related measures. For the intergroup comparison of variation before and after polishing, the Kruskal−Wallis test with Bonferroni post hoc was used considering a significance level of p < 0.05. When comparing surface roughness, significant differences were observed between Opus Bulk Fill resin composite with and without OIL control (p = 0.003) before polishing. The same occurred when comparing Tetric N-Ceram resin composite with and without OIL control (p = 0.039) after polishing. In addition, the surface roughness of Filtek Bulk Fill, Opus Bulk Fill, and Tetric N-Ceram Bulk Fill resin composites, with and without OIL control, decreased significantly after polishing (p < 0.001), while surface microhardness significantly increased (p < 0.05), with the exception of Opus Bulk Fill resin with OIL control (p = 0.413). In conclusion, OIL control and polishing significantly improved the surface roughness and surface microhardness of Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites. However, in the case of Opus Bulk Fill resin composite, only its surface roughness was significantly improved.
Collapse
Affiliation(s)
- Ann Carrillo-Marcos
- School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru; (A.C.-M.); (G.S.-C.); (L.C.-R.); (H.C.-C.); (A.C.-P.)
| | - Giuliany Salazar-Correa
- School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru; (A.C.-M.); (G.S.-C.); (L.C.-R.); (H.C.-C.); (A.C.-P.)
| | - Leonor Castro-Ramirez
- School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru; (A.C.-M.); (G.S.-C.); (L.C.-R.); (H.C.-C.); (A.C.-P.)
| | - Marysela Ladera-Castañeda
- “Grupo de Investigación Salud y Bienestar Global”, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, 15001 Lima, Peru; (M.L.-C.); (A.A.-M.)
| | | | - Hernán Cachay-Criado
- School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru; (A.C.-M.); (G.S.-C.); (L.C.-R.); (H.C.-C.); (A.C.-P.)
| | - Ana Aliaga-Mariñas
- “Grupo de Investigación Salud y Bienestar Global”, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, 15001 Lima, Peru; (M.L.-C.); (A.A.-M.)
| | - Alberto Cornejo-Pinto
- School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru; (A.C.-M.); (G.S.-C.); (L.C.-R.); (H.C.-C.); (A.C.-P.)
- “Grupo de Investigación Salud y Bienestar Global”, Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, 15001 Lima, Peru; (M.L.-C.); (A.A.-M.)
| | | | - César Félix Cayo-Rojas
- School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru; (A.C.-M.); (G.S.-C.); (L.C.-R.); (H.C.-C.); (A.C.-P.)
- Correspondence:
| |
Collapse
|
15
|
Effect of Additional Dry Heat Curing on Microflexural Strength in Three Types of Resin Composite: An In Vitro Study. CRYSTALS 2022. [DOI: 10.3390/cryst12081045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Aim: Additional dry heat curing is a method that favorably influences the mechanical properties of an indirect resin composite restoration. Microflexural strength is a property currently applied for the evaluation of indirect resin composite restorations. The aim of the present study was to assess the effect of additional dry heat curing on microflexural strength in three types of direct-use resin composites. Materials and Methods: This in vitro study consisted of 70 resin composites samples made with a 6 × 2 × 1 mm metal matrix and divided into seven experimental groups, which included Gr1a: Tetric N-Ceram without additional dry heat curing (n = 10); Gr1b: Tetric N-Ceram with additional dry heat curing (n = 10); Gr 2a: Filtek Z350 XT without additional dry heat curing (n = 10); Gr2b: Filtek Z350 XT with additional dry heat curing (n = 10); Gr3a: Filtek Z250 without additional dry heat curing (n = 10); Gr3b: Filtek Z250 with additional dry heat curing (n = 10); and Gr4: SR Nexco Paste (control) without additional dry heat curing (n = 10). The samples were stored in distilled water at 37 °C for 24 h. A universal testing machine with a 2000 N load cell at a speed of 1 mm/min was used to assess flexural strength. The data were analyzed with a parametric ANOVA test with Tukey’s post hoc intergroup factor (for groups without heat treatment) and a nonparametric Kruskall Wallis test with Bonferroni’s post hoc (for groups with heat treatment). In addition, the comparison of independent groups in each resin composite type with and without heat treatment was performed with a Mann Whitney U test. A significance level of p < 0.05 was considered. Results: The Filtek Z250 resin composite with and without additional dry heat curing presented the highest microflexural strength values with 137.27 ± 24.43 MPa and 121.32 ± 9.74 MPa, respectively, while the SR Nexco Paste (control) resin composite presented the lowest microflexural strength values with 86.06 ± 14.34 MPa compared to all the resin composites with additional dry heat curing. The Filtek Z250 and Filtek Z350XT resin composites with and without additional dry heat curing presented significantly higher microflexural strength versus the SR Nexco (p < 0.05) and Tetric N-Ceram (p < 0.05) resin composites. In addition, the Filtek Z350XT and Tetric N-Ceram resin composites with additional dry heat curing showed significantly higher microflexural strength (p < 0.05) compared to those without additional dry heat curing. Conclusions: The Filtek Z250 and Z350XT resin composites had significantly higher microflexural strength values with and without additional dry heat curing. In addition, the Filtek Z350XT and Tetric N-Ceram resin composites subjected to additional dry heat curing showed significantly higher microflexural strength compared to when they did not receive the same procedure, a situation that did not occur with the Filtek Z250 resin composite.
Collapse
|