1
|
Hiraba H, Nishio K, Takeuchi Y, Ito T, Yamamori T, Kamimoto A. Application of one-piece endodontic crowns fabricated with CAD-CAM system to molars. JAPANESE DENTAL SCIENCE REVIEW 2024; 60:81-94. [PMID: 38303746 PMCID: PMC10830429 DOI: 10.1016/j.jdsr.2023.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 12/04/2023] [Accepted: 12/26/2023] [Indexed: 02/03/2024] Open
Abstract
Computer-aided design-computer-aided manufacturing (CAD-CAM) systems have been widely used as a fabrication method for restorations because of their high efficiency and accuracy, which significantly reduces fabrication time. However, molars with insufficient clearance or short clinical crown lengths require retention holes or grooves on the preparation, making it difficult to replicate the shapes with the CAM milling system. In these cases, restorations using the lost-wax method are selected. This article focuses on one-piece endodontic crowns (endocrowns) fabricated with a CAD-CAM system (CAD-CAM endocrowns), in which their posts and crowns are integrated. Articles from July 2012 to August 2023 were searched in PubMed with the keyword "endocrown". This review discusses the application of CAD-CAM endocrowns to molars from the viewpoint of model experiment (fracture resistance, adaptation) and clinical research. This technique, which allows margins and internal gaps to be set within the clinically acceptable range, is reported to be an effective way of restoring molars with high survival rates in clinical research.
Collapse
Affiliation(s)
- Haruto Hiraba
- Department of Dental Materials, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
- Division of Biomaterials Science, Dental Research Center, Nihon University School of Dentistry, 1-8-13 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Kensuke Nishio
- Department of Complete Denture Prosthodontics, Nihon University School of Dentistry, 1-8-13 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Yoshimasa Takeuchi
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Takashi Ito
- Center of Innovative Clinical Medicine, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan
| | - Tetsuo Yamamori
- Department of Prosthetic Dentistry, School of Dentistry, Ohu University School of Dentistry, 31-1 Misumido, Tomita, Koriyama, Fukushima 963-8611, Japan
| | - Atsushi Kamimoto
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| |
Collapse
|
2
|
Xiao P, Zheng Z, Zhang Y, Zeng Y, Yan W. Accuracy and adaptation of one-piece endodontic crowns fabricated through 3D printing and milling. J Prosthet Dent 2024; 132:422-433. [PMID: 38880678 DOI: 10.1016/j.prosdent.2024.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 05/17/2024] [Accepted: 05/17/2024] [Indexed: 06/18/2024]
Abstract
STATEMENT OF PROBLEM High-level evidence regarding the accuracy and adaptation of 1-piece endodontic crowns fabricated by using 3-dimensional (3D) printing technology is lacking. PURPOSE The purpose of this in vitro study was to compare the accuracy and adaptation of 1-piece endodontic crowns produced through 3D printing and computer-numerical-control milling technology and to explore the influence of trueness on 1-piece endodontic crown adaptation. MATERIAL AND METHODS One-piece endodontic crowns were prepared for a typodont right mandibular first molar, scanned with a 3Shape E3 scanner, and designed with a computer-aided design software program. Two types of 1-piece endodontic crowns were fabricated: 3D printed by using resin and zirconia slurry and milled from Grandio and zirconia blocks. A reverse engineering software program was used to superimpose 4 groups of crowns with the reference crowns used for accuracy analysis. Microcomputed tomography was used to measure 1-piece endodontic crown adaptation. The correlation between trueness and adaptation was evaluated through the Spearman correlation test (α=.05). RESULTS Milled resin-based 1-piece endodontic crowns demonstrated better trueness on marginal and occlusal surfaces compared with 3D printed ones (P<.001). However, no significant difference was observed in the trueness of intaglio surfaces between the 2 groups (P>.05). The milled group exhibited better adaptations than the printed one (P<.05). For zirconia 1-piece endodontic crowns, no significant differences were found in trueness or adaptation between the milled and printed groups (P>.05). Notably, the trueness of the axial wall had the greatest impact on overall crown adaptation, with its adaptation closely linked to the trueness of each area, particularly the axial wall. CONCLUSIONS Milled resin-based 1-piece endodontic crowns exhibited higher levels of trueness and adaptation compared with 3D printed ones, while 3D printed zirconia 1-piece endodontic crowns were comparable with milled ones.
Collapse
Affiliation(s)
- Ping Xiao
- Graduate student, Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, PR China
| | - Ziting Zheng
- Graduate student, Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, PR China
| | - Yanli Zhang
- Doctoral student, Stomatological Hospital, Southern Medical University, Guangzhou, PR China
| | - Yuting Zeng
- Graduate student, Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, PR China
| | - Wenjuan Yan
- Professor, Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, PR China.
| |
Collapse
|
3
|
Pilecco RO, da Rosa LS, Baldi A, Machry RV, Tribst JPM, Valandro LF, Kleverlaan CJ, Scotti N, Pereira GKR. How do different intraoral scanners and milling machines affect the fit and fatigue behavior of lithium disilicate and resin composite endocrowns? J Mech Behav Biomed Mater 2024; 155:106557. [PMID: 38657286 DOI: 10.1016/j.jmbbm.2024.106557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/03/2024] [Accepted: 04/17/2024] [Indexed: 04/26/2024]
Abstract
The aim of this in vitro study was to evaluate the effect of the combinations of two different intraoral scanners (IOS), two milling machines, and two restorative materials on the marginal/internal fit and fatigue behavior of endocrowns produced by CAD-CAM. Eight groups (n= 10) were considered through the combination of TRIOS 3 (TR) or Primescan (PS) IOS; 4-axes (CR; CEREC MC XL) or 5-axes (PM; PrograMill PM7) milling machines; and lithium disilicate (LD; IPS e.max CAD) or resin composite (RC; Tetric CAD) restorative materials. Specific surface treatments were applied to each material, and the bonding to its corresponding Endocrown-shaped fiberglass-reinforced epoxy resin preparations was performed (Variolink Esthetic DC). Computed microtomography (μCT) was performed to assess the marginal/internal fit, as well as a mechanical fatigue test (20 Hz, initial load = 100 N/5000 cycles; step-size = 50 N/10,000 cycles until a threshold of 1500 N, then, the step-size was increased if needed to 100 N/10,000 cycles until failure or a threshold of 2800 N) to evaluate the restorations long-term behavior. Complementary analysis of the fracture features and surface topography in scanning electron microscopy was performed. Three-way ANOVA and Kaplan-Meier test (α = 0.05) were performed for marginal/internal fit, and fatigue behavior data, respectively. PS scanner, CR milling machine, and RC endocrowns resulted in a better marginal fit compared to their counterparts. Still, the PM machine resulted in a better pulpal space fit compared to the CR milling machine. Regardless of the scanner and milling machine, RC endocrowns exhibited superior fatigue behavior than LD ones. LD endocrowns presented margin chipping regardless of the milling machine used. Despite minor differences in terms of fit, the 'IOS' and 'milling machine' factors did not impair the fatigue behavior of endocrowns. Resin-composite restorations resulted in a higher survival rate compared to glass-ceramic ones, independently of the digital devices used in the workflow.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andrea Baldi
- Department of Surgical Sciences, Dental School, University of Turin (UNITO), Turin, Piedmont, Italy.
| | - Renan Vaz Machry
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands.
| | - Nicola Scotti
- Department of Surgical Sciences, Dental School, University of Turin (UNITO), Turin, Piedmont, Italy.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
4
|
Pilecco RO, Machry RV, Baldi A, Tribst JPM, Sarkis-Onofre R, Valandro LF, Kleverlaan CJ, Scotti N, Pereira GKR. Influence of CAD-CAM milling strategies on the outcome of indirect restorations: A scoping review. J Prosthet Dent 2024; 131:811.e1-811.e10. [PMID: 38480018 DOI: 10.1016/j.prosdent.2024.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 02/19/2024] [Accepted: 02/20/2024] [Indexed: 05/13/2024]
Abstract
STATEMENT OF PROBLEM The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. PURPOSE The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture. MATERIAL AND METHODS The protocol of this review is available online (https://osf.io/x28ps/). Studies that used at least 2 different parameters (CAM units, number of axes, digital spacers, or protocols with different rotatory instruments, grit-sizes, milling speed, or others) for milling indirect restorations were included. A structured search up to July 2023 was performed by 2 independent reviewers for articles written in English in LILACS, MEDLINE via PubMed, EMBASE, Web of Science, and Scopus. RESULTS Of 1546 studies identified, 22 were included in the review. Discrepancies were found between the planned and actual measured cement space, with a decreasing linear relationship impacting restoration adaptation at different points. The CEREC MC XL milling machine was the most used system in the included studies, with variations in bur types, milling modes, and number of burs uses affecting internal fit and surface trueness. The results demonstrated the better adaptation of restorations made with 5-axis over 3-axis milling machines. Lithium disilicate and zirconia were the most commonly used materials, and crowns and inlays were popular designs. Marginal and internal adaptation were the primary outcomes assessed using the various techniques. CONCLUSIONS The study presented a comprehensive exploration of CAM systems and parameters, and their influence on indirect restorations. The planned cement space was not properly reproduced by the milling. Bur characteristics can affect restoration fit and trueness. The 5-axis units seem to result in better-adapted restorations compared with 3- and 4-axis units.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- Postgraduate student, Postgraduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Renan Vaz Machry
- Postdoctoral student, Postgraduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Andrea Baldi
- Postdoctoral student, Department of Surgical Sciences, Dental School, Turin, Italy
| | - João Paulo Mendes Tribst
- Assistant Professor, Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, The Netherlands.
| | - Rafael Sarkis-Onofre
- Associate Professor, Graduate Program in Dentistry, Meridional Faculty, IMED, Passo Fundo, Brazil
| | - Luiz Felipe Valandro
- Full Professor, Postgraduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Cornelis Johannes Kleverlaan
- Full Professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, The Netherlands
| | - Nicola Scotti
- Associate Professor, Department of Surgical Sciences, Dental School, Turin, Italy
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, Postgraduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| |
Collapse
|
5
|
Farag E, Sabet A, Ebeid K, El Sergany O. Build angle effect on 3D-printed dental crowns marginal fit using digital light-processing and stereo-lithography technology: an in vitro study. BMC Oral Health 2024; 24:73. [PMID: 38212816 PMCID: PMC10785357 DOI: 10.1186/s12903-024-03851-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 01/02/2024] [Indexed: 01/13/2024] Open
Abstract
BACKGROUND The effect of 3D printing technology and build angle on the marginal fit of printed crowns is unclear. The objective of this research was to use digital light processing (DLP) and stereo-lithography (SLA)-based 3D printing to construct single restorations with varied build angles and to analyze the crowns' marginal fit. METHODS A prepared resin first molar was scanned utilizing an optical scanner. Three build orientations were used to construct the specimens: 0, 45, and 90º. DLP and SLA technology were used to produce the casting patterns. A digital microscope was used to measure the marginal gaps. The effect of build orientation was statistically analyzed by using Two-way ANOVA followed by pair-wise Tukey test. RESULTS Two-way ANOVA revealed a significant effect of printer technology and build angle on the marginal discrepancy of 3D printed crowns (p < 0.001). One-way ANOVA revealed that SLA printers (55.6 [± 13.59]) showed significantly better mean [± SD] marginal discrepancy in µm than DLP printers (72 [± 13.67]) (p < 0.001). Regarding build angle, one-way ANOVA revealed significant differences between the different angles. Tukeys post-hoc test revealed that 0° (48.5 [± 9.04]) had the significantly smallest marginal discrepancy followed by 45° (62.5 [± 8.05]) then 90° (80.5 [± 8.99]) (p < 0.001). CONCLUSION The build orientation affects the marginal discrepancy of single crowns manufactured utilizing DLP and SLA.
Collapse
Affiliation(s)
- Engy Farag
- Department of Fixed Prosthodontics, Faculty of Dentistry, The British University in Egypt, Cairo, Egypt
| | - Ahmed Sabet
- Department of Fixed Prosthodontics, Faculty of Dentistry, The British University in Egypt, Cairo, Egypt
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| | - Kamal Ebeid
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt.
| | - Omar El Sergany
- Department of Fixed Prosthodontics, Faculty of Dentistry, The British University in Egypt, Cairo, Egypt
| |
Collapse
|
6
|
Alkhallagi T, Alzahrani M, Alkathiri MA, Basunbul GI, Marghalani A. Vertical Marginal Discrepancy of a Monolithic Zirconia Crown with Different Cement Spaces. Int J Dent 2023; 2023:6698453. [PMID: 38098873 PMCID: PMC10721348 DOI: 10.1155/2023/6698453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 10/31/2023] [Accepted: 11/03/2023] [Indexed: 12/17/2023] Open
Abstract
The long-term clinical success of indirect restorations highly depends on their marginal integrity. The cement space is an element that might affect the marginal integrity, but it can be altered during the configuring of the computer-assisted designing/computer-aided manufacturing (CAD-CAM) restoration. However, there is controversy in the literature regarding the effect of the cement space on the precision of zirconia crown marginal adaptation. The aim of this study was to measure the vertical marginal discrepancies between different cement thickness settings for CAD-CAM monolithic zirconia restorations. Material and Methods. An artificial mandibular right molar tooth mounted on a typodont was prepared for a zirconia crown using the standard method. The study sample consisted of 30 zirconia crowns (Zenostar Zr Translucent Zirconia, Weiland Dental, Germany) milled using an (iMes-iCore) milling machine. Each group of 10 crowns was designed with 30-50 and 70 μm spacer thicknesses. The vertical marginal adaptation at the center of the four different planes (mesial, distal, buccal, and palatal) was measured under a microscope at 40x magnification. A one-way analysis of variance test was used for statistical analysis. Results. The mean of Group 30 was 27.45; of Group 50 was 22.22; and of Group 70 was 22.90. There was no statistically significant difference between the groups (p ≥ 0.5). Conclusions. The increase in the cement space up to 70 μm did not influence the vertical marginal adaptation of the monolithic zirconia crowns.
Collapse
Affiliation(s)
- Turki Alkhallagi
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Meshari Alzahrani
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Majed Ali Alkathiri
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Ghadeer I. Basunbul
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Amin Marghalani
- Department of Oral and Maxillofacial Surgery, College of Dental Medicine, Umm Al-Qura University, P.O. Box 715, Makkah, Saudi Arabia
| |
Collapse
|
7
|
Al Qahtani WM. Comparative Finite Element Analysis of Endocrowns and Traditional Restorations for Endodontically Treated Mandibular First Molars. Med Sci Monit 2023; 29:e941314. [PMID: 37941316 PMCID: PMC10644702 DOI: 10.12659/msm.941314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 08/24/2023] [Indexed: 11/10/2023] Open
Abstract
BACKGROUND This study evaluated 2 endocrown designs and traditional restoration with a conventional crown using post and core to find the best restoration design for endodontically treated mandibular first molars. MATERIAL AND METHODS Three 3D finite element models were constructed: (1) post and core restoration, (2) endocrown butt joint margin design, and (3) endocrown with shoulder finish line. The intact tooth geometry was extracted with computed tomography, then modified to the selected restoration designs. Bone and mucosa geometry was simplified and represented as 3 cylinders. Two loading cases were examined on E-max crowns as 400N and 200N vertically and 45º oblique, respectively, that were located at buccal cusp tips and central fossa by nodal force distributed on circular areas with 0.5-mm diameter in each location. RESULTS Traditional restoration kept crown deformation and stresses at lower levels than did endocrowns. Results of the butt joint margin design were comparable to that of shoulder finish line design. Cement had the lowest stress values under shoulder finish line design, while the remaining tooth indicated the superiority of butt joint margin design, with less stresses by 20% and 24%, compared with traditional and shoulder finish line restorations, respectively. CONCLUSIONS The 3 tested restoration designs worked well. Although the differences were small, according to stress analysis results, conventional restoration by post and core achieved the best performance, followed by butt joint margin, which ensures lowest level of stresses on dentine. Finally, the shoulder finish line endocrown can replace the other designs but with higher stress levels.
Collapse
|