1
|
Sawangsri K, Leelaluk S, Hsieh YL, Lee DJ. Comparison of trueness, time, and number of images among different denture digitization protocols. J Prosthodont 2024. [PMID: 39471255 DOI: 10.1111/jopr.13967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 10/12/2024] [Indexed: 11/01/2024] Open
Abstract
PURPOSE To compare trueness, time, and number of images of different denture digitization protocols. MATERIALS AND METHODS Maxillary and mandibular complete prostheses (n = 10) were fabricated and attached with four fiducial markers. Reference scans were obtained using a laboratory scanner. Test scans were obtained using three different protocols: intraoral scanner (IOS) with manufacturer's scanning pattern (MA), IOS with rolling scanning pattern (RO), and IOS- polyvinylsiloxane technique (IOS-PVS). The scan time and number of images taken were recorded for analysis. Using 3-dimensional (3D) inspection software (Geomagic control X), corresponding test scans were superimposed to the reference scan using overall best fit. For trueness analysis, the root mean square (RMS) value of the overall best-fit superimposition was calculated. One-way ANOVA followed by Games-Howell and Tukey post-hoc tests were applied to analyze trueness, scan time, and number of images. Qualitative analysis of trueness was performed using 3D color mapping. RESULTS The lowest RMS value was in the mandibular RO protocol (0.10 ±0.01 mm). The highest RMS value was mandibular scans of the IOS-PVS protocol (1.46 ± 0.09 mm). The longest digitization time was recorded in the maxillary MA group (3.34 ± 0.70 min), while the shortest was in the mandibular RO protocol (2.48 ± 0.56 min). Qualitative analysis revealed that deviation in IOS-PVS protocol occurred around the border area of the prosthesis. CONCLUSION The denture digitization protocols tested significantly affected trueness, total scanning time, and number of images. Digitizing dentures using the RO protocol improved trueness and reduced scanning time and the number of images.
Collapse
Affiliation(s)
- Kedith Sawangsri
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Satita Leelaluk
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Yuan-Lynn Hsieh
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Damian J Lee
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
| |
Collapse
|
2
|
Borbola D, Mikolicz A, Romanszky L, Sersli G, DeFee M, Renne W, Vag J. Complete-arch accuracy of seven intraoral scanners measured by the virtual-fit method. J Dent 2024; 149:105281. [PMID: 39094976 DOI: 10.1016/j.jdent.2024.105281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Revised: 07/20/2024] [Accepted: 07/30/2024] [Indexed: 08/04/2024] Open
Abstract
OBJECTIVES This study compared the accuracy of seven intraoral scanners (IOS) by the virtual-fit method. METHODS Four maxillary arches with tooth abutments were scanned with an industrial reference scanner (n=1) and by Aoralscan3, EmeraldS, Helios600, Lumina, Mediti700, Primescan, and Trios5 IOSs (each n=12). Two complete-arch fixed frameworks were designed on each IOS scan with a 70 µm (group 70) and a 90 µm internal cement space (group 70+20, additional 20 µm at the margin). The virtual-fit method was comprised of superimposing the framework designs onto the reference scan using a non-penetrating algorithm simulating the clinical try-in. Internal and marginal gaps were measured. Precision was estimated by the mean absolute errors (MAE). RESULTS In group 70, Mediti700 (43 µm), Primescan (42 µm), and EmeraldS were in the best homogenous subset for the marginal gap, followed by the Lumina (67 µm), Aoralscan3 (70 µm), and Trios5 (70 µm), whereas Helios600 (118 µm) was in the third subset. Based on the MAE at the margin, Mediti700, Trios5, and EmeraldS were in the first-best homogenous subset, followed by Primescan. Lumina and Helios600 were in the third subset, and Aoralscan3 was in the fourth subset. In group 70+20, the marginal gap was significantly decreased for Lumina and Aoralscan3, whereas MAE significantly decreased for EmeraldS and Aoralscan3. The rank of IOSs was similar for the internal gap. CONCLUSION EmeraldS, Mediti700, Primescan, and Trios5 meet the marginal and internal fit criteria for fixed tooth-borne complete arch restorations. Increasing the cement space during design could enhance restoration fit. CLINICAL SIGNIFICANCE The virtual-fit alignment method can effectively evaluate the accuracy of different intraoral scanners, offering valuable clinical guidance for distinguishing among them. Recent software and hardware versions of long-standing IOS manufacturers are suitable for fabricating complete arch restoration.
Collapse
Affiliation(s)
- Daniel Borbola
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi utca 47, H-1088, Budapest, Hungary
| | - Akos Mikolicz
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi utca 47, H-1088, Budapest, Hungary
| | - Laszlo Romanszky
- Dental technicians, Artifex Dentis Kft. Révay utca 12, H-1065 Budapest, Hungary
| | - Gyorgy Sersli
- Dental technicians, Artifex Dentis Kft. Révay utca 12, H-1065 Budapest, Hungary
| | - Michael DeFee
- Modern Optimized Dentistry Institute, 320 Broad St. #210 Charleston, SC 29401 USA
| | - Walter Renne
- Modern Optimized Dentistry Institute, 320 Broad St. #210 Charleston, SC 29401 USA
| | - Janos Vag
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi utca 47, H-1088, Budapest, Hungary.
| |
Collapse
|
3
|
Revilla-León M, Zeitler JM, Kois JC. Intraoral scanners as tracking devices: A dental protocol for assessing volumetric changes between intraoral scans. J Prosthet Dent 2024:S0022-3913(24)00364-0. [PMID: 38955599 DOI: 10.1016/j.prosdent.2024.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 05/17/2024] [Accepted: 05/21/2024] [Indexed: 07/04/2024]
Abstract
Intraoral scanners (IOSs) are digital data acquisition technologies that ease the recording of virtual diagnostic casts. Some IOSs have a specific software tool to assess volumetric changes between 2 scans acquired on the patient at different times. The scans are superimposed and volumetric differences between both meshes are reported. However, these software tools may be limited to scans captured only by the IOS of the same manufacturer. The present manuscript describes a protocol for comparing volumetric changes between 2 scans recorded using any IOS. Additionally, 1 of the scans is divided into 3 sections to minimize the alignment distortion and maximize the evaluation of the volumetric changes.
Collapse
Affiliation(s)
- Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty & Director, Research and Digital Dentistry, Kois Center, Seattle, Wash.; and Adjunct Professor, Department of Prosthodontics, Tufts University, Boston, Mass.
| | | | - John C Kois
- Founder and Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle, Wash
| |
Collapse
|
4
|
Schmalzl J, Keskeny GÁ, Hermann P, Pál A, Géczi Z, Borbély J, Róth I. Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study. J Dent 2024; 145:105014. [PMID: 38648874 DOI: 10.1016/j.jdent.2024.105014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 04/12/2024] [Accepted: 04/19/2024] [Indexed: 04/25/2024] Open
Abstract
OBJECTIVES To assess the impact of including the palate and the number of images recorded during intraoral digital scanning procedure on the accuracy of complete arch scans. METHODS An experienced operator conducted 40 digital scans of a 3D printed maxillary model and divided them into two groups: 20 with inclusion of the palate (PAL) and 20 without (NPAL). Each set of scans was performed using an intraoral scanner (IOS) (Trios 5; 3Shape A/S; Copenhagen, Denmark). The resulting STL files were imported into the Geomagic Control X software (3D Systems, Rock Hill, SC, USA) for accuracy comparison. A reference STL file was created using a 3Shape E3 laboratory scanner (3Shape Scanlt Dental 2.2.1.0; Copenhagen, Denmark). The number of images captured was recorded during the scanning procedure. RESULTS In the case of the right side no statistically significant difference in trueness was detected (84 µm ± 45.6 for PAL and 80.4 ± 40.4 µm for NPAL). In the case of the left side no significant difference in trueness was observed (215.1 ± 70.2 µm for PAL and 233.9 ± 70.7 µm for NPAL). In the case of the arch distortion a statistically significant difference in trueness was seen between the two types of scans (135.3 ± 71.9 µm for PAL and 380.4 ± 255.1 µm for NPAL). The average number of images was 831.25, and 593.8 for PAL and NPAL, respectively. CONCLUSIONS Scanning of the palatal area can significantly improve the accuracy of dental scans in cases of complete arches. In terms of the number of images, based on the current results, obvious conclusions could not be drawn, and further investigation is required. CLINICAL SIGNIFICANCE Scanning the palate may be beneficial for improving the accuracy of intraoral scans in dentate patients. Consequently, this should be linked to an appropriate scanning strategy that predicts palatal scanning.
Collapse
Affiliation(s)
- Judit Schmalzl
- Department of Prosthodontics, Semmelweis University, Szentkirályi street 47, Budapest 1088, Hungary; Semmelweis University's School of Ph.D. Studies, Üllői u. 26, Budapest 1085, Hungary.
| | - György Árpád Keskeny
- Semmelweis University's School of Ph.D. Studies, Üllői u. 26, Budapest 1085, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Semmelweis University, Szentkirályi street 47, Budapest 1088, Hungary
| | - Adrienn Pál
- Department of Prosthodontics, Semmelweis University, Szentkirályi street 47, Budapest 1088, Hungary; Semmelweis University's School of Ph.D. Studies, Üllői u. 26, Budapest 1085, Hungary
| | - Zoltán Géczi
- Department of Prosthodontics, Semmelweis University, Szentkirályi street 47, Budapest 1088, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Semmelweis University, Szentkirályi street 47, Budapest 1088, Hungary
| | - Ivett Róth
- Department of Prosthodontics, Semmelweis University, Szentkirályi street 47, Budapest 1088, Hungary
| |
Collapse
|
5
|
Baltacioğlu İH, Demirel G, Öztürk B, Aydin F, Özcan M. An evaluation of dental paste-like bulk-fill composite wear using intra-oral scanner. Dent Mater J 2024; 43:446-452. [PMID: 38692905 DOI: 10.4012/dmj.2023-288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2024]
Abstract
This study evaluates the wear resistance of dental paste-like bulk-fill composites compared to conventional paste-like composite resins using an intraoral scanner and 3-D analyzing software. Six different dental composite materials, including five bulk-fill composites and one conventional composite, were tested alongside natural human enamel as a control group. A computer-controlled chewing simulator for wear testing. A one-way ANOVA test was used to identify any significant differences between the means of the tested dental composite materials α=0.05. The results showed variability among bulk-fill composites, with some demonstrating wear resistance similar to conventional composites (p<0.05). Human enamel displayed the lowest wear values, but some bulk-fill composites matched this resistance(p>0.05). Significant variability was observed among bulk-fill composites but the results were comparable to those of conventional composites. The enamel control group demonstrated the lowest wear values, with some bulk-fill composites showing similar wear resistance. This study provides valuable information about the wear resistance of contemporary bulk-fill composite materials, commonly used in current clinical practice, contributing to enhancing clinical procedures.
Collapse
Affiliation(s)
| | - Gülbike Demirel
- Department of Restorative Dentistry, Faculty of Dentistry, Ankara University
| | - Burcu Öztürk
- Department of Restorative Dentistry, Faculty of Dentistry, Ankara University
| | - Fulya Aydin
- Department of Restorative Dentistry, Faculty of Dentistry, Ankara Medipol University
| | - Mutlu Özcan
- Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich
| |
Collapse
|
6
|
Eldin BSG, Talaat IA, Nawar NHH, Mohamed AMA. Effect of different fabrication workflows on the passive fit of screw-retained bar splinting two interforaminal implants: a parallel blinded randomised clinical trial. BMC Oral Health 2024; 24:410. [PMID: 38566034 PMCID: PMC10985940 DOI: 10.1186/s12903-024-04157-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 03/18/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.
Collapse
Affiliation(s)
- Bassant Sherif Gamal Eldin
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt.
| | - Ingy Amin Talaat
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| | - Noha Helmy Hassan Nawar
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| | - Ahmed Mostafa Abdelfattah Mohamed
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| |
Collapse
|
7
|
Le Texier L, Nicolas E, Batisse C. Evaluation and comparison of the accuracy of three intraoral scanners for replicating a complete denture. J Prosthet Dent 2024; 131:706.e1-706.e8. [PMID: 38310062 DOI: 10.1016/j.prosdent.2024.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 01/09/2024] [Accepted: 01/10/2024] [Indexed: 02/05/2024]
Abstract
STATEMENT OF PROBLEM Technological advances in digital acquisition tools have increased the scope of intraoral scanners (IOSs), including scanning a removable complete denture (RCD) to replicate it. However, studies assessing the accuracy of IOSs for replicating a maxillary or mandibular RCD are lacking. PURPOSE The purpose of this in vitro study was to evaluate the accuracy (trueness and precision) of 3 IOSs while replicating a maxillary and mandibular RCD. MATERIAL AND METHODS One maxillary and 1 mandibular RCD were scanned with a desktop scanner (D2000) to obtain the reference model. Two operators scanned each RCD 5 times with 3 different IOSs (TRIOS 4, Primescan, and IS3800), following a predefined acquisition protocol. The 60 study models obtained were compared with the reference model using the Geomagic software program. For each comparison, the mean and standard deviation of discrepancy were calculated. Distances were measured on both the reference and the study model, and differences were calculated to assess whether sagittal or transverse deformations were present. The tolerance percentage of the volume of the digital model compared with the volume of the reference model was determined (difference tolerance was set at 0.1 mm). A univariate analysis of variance followed by a post hoc analysis using the Student-Newman-Keuls (α=.05) test was performed to determine the truest and the most precise IOS. RESULTS The TRIOS 4 and Primescan IOSs had comparable trueness, with mean dimensional variations of 47 ±27 µm and 57 ±8 µm respectively compared with the reference model. The IS3800 had a lower trueness (98 ±35 µm). Primescan was significantly more precise with a mean standard deviation of 64 ±15 µm (P<.05). The TRIOS 4 (141 ±48 µm) and IS3800 (129 ±24 µm) had comparable precision. Primescan showed the least sagittal and transverse deformation. CONCLUSIONS This study determined that an RCD can be replicated using an IOS, although all IOSs did not have equal accuracy. An in vivo study needs to assess whether this procedure is clinically acceptable.
Collapse
Affiliation(s)
- Louise Le Texier
- Resident, Department of Odontology, Faculty of Odontology, University Clermont Auvergne, Clermont Ferrand, France
| | - Emmanuel Nicolas
- Professor, Department of Odontology, Faculty of Odontology, University Clermont Auvergne, Clermont Ferrand, France
| | - Cindy Batisse
- Lecturer, Prosthetic Department, Faculty of Odontology, University Clermont Auvergne, Clermont Ferrand, France.
| |
Collapse
|
8
|
Son YT, Son K, Eo GO, Lee KB. Feasibility of images acquired using smartphone camera for marginal and internal fit of fixed dental prosthesis: comparison and correlation study. Sci Rep 2024; 14:5291. [PMID: 38438467 PMCID: PMC10912410 DOI: 10.1038/s41598-024-55711-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 02/27/2024] [Indexed: 03/06/2024] Open
Abstract
This study aimed to measure marginal and internal fit using images captured with both an optical microscope and a smartphone camera, comparing the fit measurement performance of these devices and analyzing their correlation. Working casts (with 10 posterior and 10 anterior teeth) created to fabricate fixed dental prostheses were used. These working casts were scanned using a desktop scanner (E1) to design an interim crown, and the designed interim crown was fabricated using a three-dimensional (3D) printer. Utilizing the silicone replica technique, the fabricated interim crown replicated the fit, which was then captured using both an optical microscope and a smartphone camera. The captured images were used to measure the marginal and internal fit according to the imaging device. Intraclass correlation coefficients (ICC) were used for reliability analysis according to the imaging device. Furthermore, the Wilcoxon signed-rank test was adopted for the comparative evaluation of the marginal and internal fit between the imaging devices (α = 0.05). The measurement results of the marginal and internal fit according to the optical microscope and smartphone camera did exhibit a significant difference (P < 0.05). The ICC between the two devices showed an "excellent" agreement of over 0.9 at all measurement points (P < 0.001). A smartphone camera could be used to obtain images for evaluating the marginal and internal fit.
Collapse
Affiliation(s)
- Young-Tak Son
- Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea
- Advanced Dental Device Development Institute, Kyungpook National University, 2177 Dalgubuldaero, Jung-Gu, Daegu, 41940, Republic of Korea
| | - KeunBaDa Son
- Advanced Dental Device Development Institute, Kyungpook National University, 2177 Dalgubuldaero, Jung-Gu, Daegu, 41940, Republic of Korea
| | - Gyeong-O Eo
- Department of Smart Software, Yonam Institute of Technology, Jinju-Si, Gyeongsangnam-Do, Republic of Korea
| | - Kyu-Bok Lee
- Advanced Dental Device Development Institute, Kyungpook National University, 2177 Dalgubuldaero, Jung-Gu, Daegu, 41940, Republic of Korea.
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
| |
Collapse
|
9
|
Loumprinis N, Michou S, Rahiotis C. Different Methods of Scan Alignment in Erosive Tooth Wear Measurements: An In Vitro Study. Dent J (Basel) 2024; 12:34. [PMID: 38392238 PMCID: PMC10887586 DOI: 10.3390/dj12020034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/27/2024] [Accepted: 02/02/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Model alignment in cases of erosive tooth wear can be challenging, and no method has been reported to outweigh the others. METHODS Extracted human teeth were mounted on two models and scanned at different times, from 1 h to 2 weeks, with an intraoral scanner (3Shape TRIOS 4) before and after immersion in Monster® energy drink and tap water. The scans were superimposed (3Shape TRIOS Patient Monitoring, Version 2.2.3.3, 3Shape A/S, Copengagen, Denmark). Best fit, best-fit tooth comparison, reference best fit using fillings, and palatal rugae as reference points were used for alignment. Surface profile differences were calculated in a cross-section view. The nonparametric Bland-Altman and Kruskal-Wallis tests were used. RESULTS First, statistically significant differences were marked after 4 days of immersion. The measurements obtained after 2 weeks of immersion were statistically significantly different from the measurements obtained at the different time points until 1 week. No statistically significant differences (p < 0.05) were observed among the alignment methods at any time. CONCLUSION In comparison to the best-fit model, both palatal rugae and fillings can be used. The best-fit tooth comparison method is a reliable option; however, it should be used with caution in cases of major surface loss.
Collapse
Affiliation(s)
- Nikolaos Loumprinis
- School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Stavroula Michou
- Department of Odontology, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Christos Rahiotis
- School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
| |
Collapse
|
10
|
Petrović V, Šlaj M, Buljan M, Čivljak T, Zulijani A, Perić B. Comparison of Tooth Size Measurements in Orthodontics Using Conventional and 3D Digital Study Models. J Clin Med 2024; 13:730. [PMID: 38337424 PMCID: PMC10856778 DOI: 10.3390/jcm13030730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/24/2024] [Accepted: 01/25/2024] [Indexed: 02/12/2024] Open
Abstract
(1) Background: The objective of this study was to assess which digitization method produces the biggest deviation in the 3D images of tooth size from plaster models made using alginate impressions, which are considered the gold standard in orthodontics. (2) Methods: The sample used in this study included 30 subjects (10 males and 20 females). Measurements were made on four types of models: (1) digital models obtained through intraoral scanning and digitized models of plaster cast made from (2) alginate impressions, (3) silicone impressions, and (4) conventional plaster models. Mesio-distal (MD) and buccal/labial-lingual/palatal (BL) dimensions were measured on the reference teeth of the right side of the jaw (central incisor, canine, first premolar, and first molar). Comparisons of tooth size between the methods were conducted using a repeated measurement analysis of variance and the Friedman test, while the intraclass correlation coefficient was used to determine agreement between the different methods. (3) Results: The results showed a similar level of agreement between the conventional and digital models in both jaws and the anterior, middle, and posterior segments. Better agreement was found for the MD measurements (r = 0.337-0.798; p ≤ 0.05) compared to the BL measurements (r = 0.016-0.542), with a smaller mean difference for MD (0.001-0.50 mm) compared to BL (0.02-1.48 mm) and a smaller measurement error for MD (0.20-0.39) compared to BL (0.38-0.89). There was more frequently a better level of agreement between 3D images than measurements made using a digital caliper on the plaster models with 3D images. (4) Conclusions: The differences in measurements between the digital models and conventional plaster models were small and clinically acceptable.
Collapse
Affiliation(s)
| | - Martina Šlaj
- School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (M.Š.); (B.P.)
| | - Mia Buljan
- General Hospital ‘Dr Josip Benčević’, 35000 Slavonski Brod, Croatia;
| | | | - Ana Zulijani
- Department of Oral Surgery, Clinical Hospital Center Rijeka, 51000 Rijeka, Croatia
- Department of Dental Medicine, Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
| | - Berislav Perić
- School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (M.Š.); (B.P.)
- Department of Oral and Maxillofacial Surgery, University Hospital Dubrava, 10000 Zagreb, Croatia
| |
Collapse
|
11
|
Zarauz C, Pradíes GJ, Chebib N, Dönmez MB, Karasan D, Sailer I. Influence of age, training, intraoral scanner, and software version on the scan accuracy of inexperienced operators. J Prosthodont 2023; 32:135-141. [PMID: 37837217 DOI: 10.1111/jopr.13785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023] Open
Abstract
PURPOSE To evaluate the effect of operator age on the scan accuracy (trueness and precision) of inexperienced operators when compared with experienced operators, and how training, intraoral scanner (IOS), and software version affect scan accuracy. MATERIAL AND METHODS Thirty-four operators were sorted into groups: G1 (operators <25 years old, no experience), G2 (operators >40 years old, no experience), and G3 (experienced IOS operators). They conducted partial-arch scans before and after a 4-session training with two IOSs (Trios 3 and True Definition) and two software versions. These scans were compared with the reference scans obtained from conventional impressions and a laboratory scanner (IScan D103i) to evaluate trueness (mean root mean square values) and precision (standard deviation of root mean square values) with a software program (Geomagic Control X). Kruskal-Wallis and post-hoc Dunn's tests were used to evaluate the effect of age on the scan accuracy of inexperienced groups when compared with experienced operators, while the effect of training, IOS, and software version on scan accuracy was evaluated with Wilcoxon or Mann-Whitney U tests (α = 0.05). RESULTS Before training, G1 and G2 scans had similar accuracy (p ≥ 0.065). After training, G1 scans had higher accuracy when IOS data was pooled and had higher precision with TD (p ≤ 0.004). Training increased the scan accuracy (p < 0.001), while newer software increased the trueness of inexperienced operator scans (p = 0.015). CONCLUSIONS Age affected the scan accuracy of inexperienced operators after training, indicating that extended training may be required for older operators. Training increased the scan accuracy, and newer software increased the trueness of inexperienced operator scans.
Collapse
Affiliation(s)
- Cristina Zarauz
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Guillermo Jesus Pradíes
- Department of Conservative and Buccofacial Prosthesis, Facultad de Odontología, Universidad Complutense de Madrid, Madrid, Spain
| | - Najla Chebib
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Mustafa Borga Dönmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
- Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Duygu Karasan
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
12
|
Vag J, Stevens CD, Badahman MH, Ludlow M, Sharp M, Brenes C, Mennito A, Renne W. Trueness and precision of complete arch dentate digital models produced by intraoral and desktop scanners: An ex-vivo study. J Dent 2023; 139:104764. [PMID: 37898433 DOI: 10.1016/j.jdent.2023.104764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/21/2023] [Accepted: 10/25/2023] [Indexed: 10/30/2023] Open
Abstract
OBJECTIVES The study aimed to compare the trueness and precision of five intraoral scanners (Emerald S, iTero Element 5D, Medit i700, Primescan, and Trios 4) and two indirect digitization techniques for both teeth and soft tissues on fresh mandibular and maxillary cadaver jaws. METHODS The maxilla and mandible of a fully dentate cadaver were scanned by the ATOS industrial scanner to create a master model. Then, the specimens were scanned eight times by each intraoral scanner (IOS). In addition, 8 polyvinylsiloxane (PVS) impressions were made and digitized with a Medit T710 desktop scanner. Stone models were then poured and again scanned with the desktop scanner. All IOS, PVS, and stone models were compared to the master model to calculate the mean absolute surface deviation for mandibular teeth, maxillary teeth, and palate. RESULTS For mandibular teeth, the PVS trueness was only significantly better than the Medit i700 (p < 0.001) and Primescan (p < 0.05). In maxillary teeth, the PVS trueness was significantly better than all IOSs (p < 0.05-0.001); the stone trueness was significantly better than Emerald S (p < 0.01), Medit i700 (p < 0.001) and Primescan (p < 0.01). In the palate, PVS and stone trueness were significantly lower than the iTero Element 5D (p < 0.01) and Trios 4 (p < p < 0.01). Stone trueness was significantly lower than the Medit i700 (p < 0.05). The precision in the palate was significantly lower for PVS and stone than for Emerald S (p < 0.01, p < 0.05), iTero Element 5D (p < 0.01, p < 0.01), Primescan (p < 0.001, p < 0.001), and Trios 4 (p < 0.001, p < 0.01). Significant differences in trueness between the IOSs were observed only in the mandibular teeth. The Medit i700 performed worse than Emerald S (p < 0.01) and iTero Element 5D (p < 0.01). For mandibular teeth, the Medit i700 was significantly more precise than Primescan (p < 0.01) and the Emerald S (p < 0.05). The Trios 4 was significantly less precise than Emerald S (p < 0.05). The precision of Medit i700 was significantly worse than iTero Element 5D (p < 0.01) for maxillary teeth, as well as the Primescan (p < 0.01) and Trios 4 (p < 0.05) for the palate. CONCLUSIONS In general, indirectly digitized models from PVS impressions had higher trueness than IOS for maxillary teeth; precision between the two methods was similar. IOS was more accurate for palatal tissues. The differences in trueness and precision for mandibular teeth between the various techniques were negligible. CLINICAL SIGNIFICANCE All investigated IOSs and indirect digitization could be used for complete arch scanning in mandibular and maxillary dentate arches. However, direct optical digitization is preferable for the palate due to the low accuracy of physical impression techniques for soft tissues.
Collapse
Affiliation(s)
- Janos Vag
- Department of Restorative Dentistry and Endodontics, Semmelweis University, Szentkirályi Street 47, Budapest 1088, Hungary.
| | | | - Mohammed H Badahman
- Digital Dentistry Masters Program, Medical University of South Carolina, Charleston, SC, USA
| | - Mark Ludlow
- Section Head of Implant Dentistry, Digital Dentistry, And Removable Prosthodontics at the University of Utah School of Dentistry, UT, USA
| | - Madison Sharp
- Senior Dental Student, Medical University of South Carolina, Charleston, SC, USA
| | - Christian Brenes
- Director of Digital Dentistry Masters Program, Medical University of South Carolina, Charleston, SC, USA
| | | | - Walter Renne
- Modern Optimized Dentistry Institute, Charleston, SC, USA
| |
Collapse
|
13
|
Vo HM, Huynh NCN, Tran TTN, Hoang HT, Nguyen ATL. Influence of titanium dioxide and composite on the accuracy of an intraoral scanner for bilateral upper posterior edentulous jaw (Kennedy class I) scanning: An in vitro study. J Dent 2023; 139:104747. [PMID: 37863172 DOI: 10.1016/j.jdent.2023.104747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 10/10/2023] [Accepted: 10/18/2023] [Indexed: 10/22/2023] Open
Abstract
OBJECTIVES The accuracy of 3-dimensional images produced by the intraoral scanner (IOS) is affected by scanning-aid materials. This in vitro study aimed to elucidate the influence of scanning-aid materials on the accuracy (trueness and precision) of digital scanning on the bilateral upper posterior edentulous jaw (Kennedy class I). METHODS The asymmetrical bilateral upper posterior edentulous model (reference model) was generated using a 3D printer with three groups (application of TiO2 powder - composite and no-treatment control). The experimental scans were executed (n = 10 per group) using TRIOS3 (3shape), while one reference scan was obtained by an industrial scanner (Solutionix - C500). Values of trueness and precision were evaluated using the 3D superimposition method on mean deviation values. The accuracy was assessed using mean deviation values following the 3D superimposition method. RESULTS IOS had high trueness (20.6 µm), and significant differences were found between the no-treatment and TiO2 groups. Considering the cut-off value of deviations as 300 µm for clinical acceptability, the analysis clarified the most variations in the control group. There was a significant difference between the no-treatment group and others in the maxillary tuberosity area relating to long-span edentulous. The composite group had the best precision values (1.1 µm). Significant differences were found between composite and TiO2 groups (2.7 µm). CONCLUSIONS The bilateral upper posterior edentulous jaw digital impressions obtained using IOS were accurate. However, the digital images in the palate and maxillary tuberosity area related to long-span edentulous differed significantly. TiO2-containing powder and composite landmarks affected the accuracy and stability of the IOS. CLINICAL SIGNIFICANCE Scanning aid materials can increase the accuracy of the bilateral upper posterior edentulous jaw scanning with IOS.
Collapse
Affiliation(s)
- Hung Manh Vo
- Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, 652 Nguyen Trai, Ward 11, District 5, Ho Chi Minh City 749000, Vietnam
| | - Nam Cong-Nhat Huynh
- Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, 652 Nguyen Trai, Ward 11, District 5, Ho Chi Minh City 749000, Vietnam.
| | - Trang Thi-Ngoc Tran
- Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, 652 Nguyen Trai, Ward 11, District 5, Ho Chi Minh City 749000, Vietnam
| | - Hung Trong Hoang
- Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, 652 Nguyen Trai, Ward 11, District 5, Ho Chi Minh City 749000, Vietnam
| | - Anh Thi-Lan Nguyen
- Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, 652 Nguyen Trai, Ward 11, District 5, Ho Chi Minh City 749000, Vietnam
| |
Collapse
|
14
|
De Rubertis C, Ferrante F, Stefanelli N, Friuli M, Madaghiele M, Demitri C, Palermo A. The accuracy of intra-oral scanners in full arch implant rehabilitation: a narrative review. Br Dent J 2023; 235:887-891. [PMID: 38066152 DOI: 10.1038/s41415-023-6550-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 05/24/2023] [Accepted: 05/29/2023] [Indexed: 12/18/2023]
Abstract
This narrative review aims to study the accuracy of different intra-oral scanner (IOS) devices already available on the market. The accuracy emerged during in vitro, in vivo and ex vivo studies made with IOS devices during the scan of a full arch implant rehabilitation that have been analysed to evaluate which device may be the most suitable in this clinical situation. The literature review was performed by searching topics and keywords using the PubMed and Medline databases, for example, 'digital workflow', 'full arch', 'full arch implant rehabilitation' and 'accuracy of IOS'. Inclusion and exclusion criteria for studies were: correct IMRAD (introduction, methods, results and discussion) structure; article with clear and detailed objectives; consistency of the articles with the purpose of the review; two-year range from the year of publication of the article; reproducible materials and methods; and correct follow-up. Most of the intra-oral scanners employed in vitro provided acceptable accuracy (below a threshold of 150 μm). The main parameters identified for their influence on precision were interim plant distance, body scan design, scanning pattern and operator experience. Even though literature is limited, significant differences emerged between the different models of intra-oral scanners evaluated in the studies considered within this review.
Collapse
Affiliation(s)
| | - Franco Ferrante
- Specialist in Oral Surgery, Private Practitioner, Lecce, Italy
| | | | - Marco Friuli
- Department of Engineering for Innovation, University of Salento, Lecce 73100, Italy.
| | - Marta Madaghiele
- Department of Engineering for Innovation, University of Salento, Lecce 73100, Italy
| | - Christian Demitri
- Department of Engineering for Innovation, University of Salento, Lecce 73100, Italy
| | - Andrea Palermo
- College of Medicine and Dentistry, Birmingham, B4 6BN, United Kingdom
| |
Collapse
|
15
|
Revilla-León M, Barmak AB, Tohme H, Yilmaz B, Kois JC, Gómez-Polo M. Factors that influence the accuracy of maxillomandibular relationship at maximum intercuspation acquired by using intraoral scanners: A systematic review. J Dent 2023; 138:104718. [PMID: 37775027 DOI: 10.1016/j.jdent.2023.104718] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/11/2023] [Accepted: 09/20/2023] [Indexed: 10/01/2023] Open
Abstract
OBJECTIVE To review the factors that influence the accuracy of the maxillomandibular relationship at maximum intercuspation (MIP) acquired by using intraoral scanners (IOSs). MATERIAL AND METHODS A systematic search was performed using five databases: MEDLINE/PubMed, Cochrane, Embase, World of Science, and Scopus. A manual search was also completed. Studies assessing the factors that influence the MIP acquired by using IOSs were included and organized based on the analyzed factor. Studies were evaluated by applying the Joanna Briggs Institute Critical Appraisal Checklist. RESULTS Twenty-nine articles were included. Seven factors have been identified: IOS system, scan extension, edentulous areas, number, location, and extension of occlusal records, occlusal force, tooth mobility, and alignment methods. Nine studies evaluated the influence of IOS system. Four studies assessed the influence of the extension of the arch scan. Three studies evaluated the effect of edentulous spaces. Four studies agreed on the impact of the number, location, and extension of the occlusal records on the MIP accuracy. One study assessed the influence of the occlusal force, showing a smaller average interocclusal space with increased occlusal force. One study evaluated the influence of tooth mobility. Seven studies analyzed the influence of the alignment method on the MIP accuracy. CONCLUSIONS Most of the studies reported no difference on the MIP accuracy between half- and complete-arch scans. Areas with 2 or more missing teeth reduce the MIP accuracy. A bilateral and frontal record including 2 teeth or a bilateral posterior occlusal including at least 4-teeth is indicated for maximizing the MIP accuracy. CLINICAL IMPLICATIONS When a complete-arch intraoral scans is obtained, a bilateral and frontal record including 2 teeth or a bilateral posterior occlusal record including at least 4-teeth is recommended for maximizing the accuracy of the MIP. When a half-arch intraoral scan is acquired, a posterior occlusal record including at least 4-teeth is indicated for optimizing the accuracy of the MIP.
Collapse
Affiliation(s)
- Marta Revilla-León
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA, USA; Faculty & Director of Research and Digital Dentistry, Kois Center, Seattle, WA, USA; Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, MA, USA.
| | - Abdul B Barmak
- Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY, USA
| | - Hani Tohme
- Founder and Head of Digital, AI, and Evolving Technologies, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| | - John C Kois
- Founder and Director Kois Center, Seattle, WA, USA; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, WA, USA; Private Practice, Seattle, WA, USA
| | - Miguel Gómez-Polo
- School of Dentistry, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
16
|
Alkadi L. A Comprehensive Review of Factors That Influence the Accuracy of Intraoral Scanners. Diagnostics (Basel) 2023; 13:3291. [PMID: 37958187 PMCID: PMC10650453 DOI: 10.3390/diagnostics13213291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 10/19/2023] [Accepted: 10/22/2023] [Indexed: 11/15/2023] Open
Abstract
Intraoral scanners (IOSs) have become increasingly popular in the field of dentistry for capturing accurate digital impressions of patients' teeth and oral structures. This study investigates the various factors influencing their accuracy. An extensive search of scholarly literature was carried out via PubMed, utilizing appropriate keywords. Factors evaluated in the included studies were categorized into three primary divisions: those related to the operator, the patient, and the IOS itself. The analysis demonstrated that the accuracy of intraoral scanning is influenced by various factors such as scanner selection, operator skill, calibration, patient's oral anatomy, ambient conditions, and scanning aids. Maintaining updated software and understanding factors beyond scanner resolution are crucial for optimal accuracy. Conversely, smaller IOS tips, fast scanning speeds, and specific scanning patterns compromise the accuracy and precision. By understanding these factors, dental professionals can make more informed decisions and enhance the accuracy of IOSs, leading to improved final dental restorations.
Collapse
Affiliation(s)
- Lubna Alkadi
- Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, National Guard Health Affairs, Riyadh 11426, Saudi Arabia;
- King Abdullah International Medical Research Center, National Guard Health Affairs, Riyadh 11481, Saudi Arabia
| |
Collapse
|
17
|
Schmalzl J, Róth I, Borbély J, Hermann P, Vecsei B. The effect of generation change on the accuracy of full arch digital impressions. BMC Oral Health 2023; 23:766. [PMID: 37853398 PMCID: PMC10585882 DOI: 10.1186/s12903-023-03476-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/29/2023] [Indexed: 10/20/2023] Open
Abstract
PURPOSE This study is aimed to evaluate the effect of generation change on accuracy of IOSs on full-arch scans and the inter-operator reliability. METHODS In this study, 6 different IOS were tested: 3Shape Trios 3 (20.1.2.), 3Shape Trios 4 (20.1.1.), Medit i500 (2.3.6.), Medit i700 (2.4.6.), Planmeca Emerald (6.0.1.) and Planmeca Emerald S (6.0.1.). Eighteen dental students, inexperienced in scanning, took part in this study as operators. Each operator made 10 digital impressions; altogether, 30 impressions were made by each scanner. The 30 STL files were imported to the Geomagic Control X program, where they were compared to a reference STL file; the surface point's deviation of the full arch and the distance between the second molars' distobuccal cusps were measured, the inter-operator reliability was also investigated. RESULTS A significant increase in accuracy was found between Trios 3 and 4 in the case of both parameters and between Medit i500 and i700 in the case of full arch. There was no significant difference between Planmeca generations. In case of the inter-operator reliability no significant difference was detected. CONCLUSION Within this current study's limitation, it can be concluded that surface digitalization's accuracy can be modified with generation changes and that digital technology is less technique sensitive than traditional impression taking.
Collapse
Affiliation(s)
- Judit Schmalzl
- Department of Prosthodontics, Semmelweis University, Szentkiralyi street 47, Budapest, 1088, Hungary.
| | - Ivett Róth
- Department of Prosthodontics, Semmelweis University, Szentkiralyi street 47, Budapest, 1088, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Semmelweis University, Szentkiralyi street 47, Budapest, 1088, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Semmelweis University, Szentkiralyi street 47, Budapest, 1088, Hungary
| | - Bálint Vecsei
- Department of Prosthodontics, Semmelweis University, Szentkiralyi street 47, Budapest, 1088, Hungary
| |
Collapse
|
18
|
Bittar E, Binvignat P, Villat C, Maurin JC, Ducret M, Richert R. Assessment of guide fitting using an intra-oral scanner: An in vitro study. J Dent 2023; 135:104590. [PMID: 37327983 DOI: 10.1016/j.jdent.2023.104590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 06/11/2023] [Accepted: 06/13/2023] [Indexed: 06/18/2023] Open
Abstract
OBJECTIVES The aim of this study was to evaluate the capacity of an intra-oral scanner (IOS) to assess the position of an endodontic guide in vitro. METHODS Fourteen extracted human teeth were placed into a maxillary model and scanned using computed tomography and a reference laboratory scanner. An ideal endodontic guide was then created and modified by adding defects of different thicknesses to simulate incorrect positions: 50 μm, 150 μm, 400 μm, and 1000 μm. For each thickness, guides were printed three times and each guide was scanned by three experimented operators using a Trios 4 IOS (3Shape, Copenhagen, Denmark). The 36 scans were compared using a best-fit alignment to the master model without defect to define the accuracy of the method and the positioning error. RESULTS The IOS presented a mean trueness of 1.28 μm (SD= 12.70) and a mean precision of 11.52 μm (SD= 62.17). Considering all sizes of defect, the mean measured position of the endodontic guide was highly correlated (R>0.99) with the expected position. Compared to the ideal guide, there was a mean linear deviation of 46.11 μm (SD= 23.21) and a mean angular deviation of 5.9° (SD= 1.2); this deviation was not influenced by the operator. CONCLUSION The present study found that an IOS had good performance to detect a positioning error of the endodontic guide in vitro. CLINICAL SIGNIFICANCE This new application of IOS has a promising potential in clinical practice to assist practitioners during the fitting of guides.
Collapse
Affiliation(s)
- Elias Bittar
- Hospices Civils de Lyon, PAM Odontologie, Lyon 69007, France
| | | | - Cyril Villat
- Hospices Civils de Lyon, PAM Odontologie, Lyon 69007, France; Laboratoire des Multimatériaux et Interfaces, UMR 5615 CNRS/UCBL, Lyon 69008, France
| | - Jean-Christophe Maurin
- Hospices Civils de Lyon, PAM Odontologie, Lyon 69007, France; Laboratoire de Biologie Tissulaire et Ingénierie thérapeutique, UMR 5305 CNRS/UCBL, Lyon 69008, France
| | - Maxime Ducret
- Hospices Civils de Lyon, PAM Odontologie, Lyon 69007, France; Laboratoire de Biologie Tissulaire et Ingénierie thérapeutique, UMR 5305 CNRS/UCBL, Lyon 69008, France
| | - Raphaël Richert
- Hospices Civils de Lyon, PAM Odontologie, Lyon 69007, France; Laboratoire de Mécanique des Contacts et structures, UMR 5259 CNRS/INSA/Univ, Villeurbanne, Lyon 69100 France.
| |
Collapse
|