1
|
Petit E, Bavykina V, Thibault M, Bilodeau A, Choinière W, Brosseau JP, Laurent B, Lauzon MA. Assessing tissue mechanical properties: Development of a custom-made tensile device and application on rodents sciatic nerves. J Mech Behav Biomed Mater 2024; 159:106709. [PMID: 39216337 DOI: 10.1016/j.jmbbm.2024.106709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 08/22/2024] [Accepted: 08/24/2024] [Indexed: 09/04/2024]
Abstract
The development of biomaterials such as synthetic scaffolds for peripheral nerve regeneration requires a precise knowledge of the mechanical properties of the nerve in physiological-like conditions. Mechanical properties (Young's modulus, maximum stress and strain at break) for peripheral nerves are scarce and large discrepancies are observed in between reports. This is due in part to the absence of a robust testing device for nerves. To overcome this limitation, a custom-made tensile device (CMTD) has been built. To evaluate its reproducibility and accuracy, the imposed speed and distance over measured speed and distance was performed, followed by a validation using poly(dimethylsiloxane) (PDMS), a commercial polymer with established mechanical properties. Finally, the mechanical characterization of rodents (mice and rats) sciatic nerves using the CMTD was performed. Mouse and rat sciatic nerves Young's modulus were 4.57 ± 2.04 and 19.2 ± 0.86 MPa respectively. Maximum stress was 1.26 ± 0.56 MPa for mice and 3.81 ± 1.84 MPa for rats. Strain at break was 53 ± 17% for mice and 32 ± 12% for rats. The number of axons per sciatic nerve was found to be twice higher for rats. Statistical analysis of the measured mechanical properties revealed no sex-related trends, for both mice and rats (except for mouse maximum stress with p=0.03). Histological evaluation of rat sciatic nerve corroborated these findings. By developing a robust CMTD to establish the key mechanical properties (Young's modulus, maximum stress and strain at break) values for rodents sciatic nerves, our work represent an essential step toward the development of better synthetic scaffolds for peripheral nerve regeneration.
Collapse
Affiliation(s)
- Eve Petit
- Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, J1K 2R1, QC, Canada
| | - Viktoriia Bavykina
- Department of Biochemistry and Functional Genomics, Université de Sherbrooke, Sherbrooke, J1E 4K8, QC, Canada
| | - Martin Thibault
- Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, J1K 2R1, QC, Canada
| | - André Bilodeau
- Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, J1K 2R1, QC, Canada
| | - William Choinière
- Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, J1K 2R1, QC, Canada
| | - Jean-Philippe Brosseau
- Department of Biochemistry and Functional Genomics, Université de Sherbrooke, Sherbrooke, J1E 4K8, QC, Canada; Cancer Research Institute, Université de Sherbrooke, Sherbrooke, J1E 4K8, QC, Canada
| | - Benoit Laurent
- Department of Biochemistry and Functional Genomics, Université de Sherbrooke, Sherbrooke, J1E 4K8, QC, Canada; Research Center on Aging, CIUSSS de l'ESTRIE-CHUS, Sherbrooke, J1H 4C4, QC, Canada
| | - Marc-Antoine Lauzon
- Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, J1K 2R1, QC, Canada; Research Center on Aging, CIUSSS de l'ESTRIE-CHUS, Sherbrooke, J1H 4C4, QC, Canada; The Quebec Network for Research on Protein Function, Engineering, and Applications, Montreal, H2X 3Y7, QC, Canada.
| |
Collapse
|
2
|
Roth K, Liu W, LeBar K, Ahern M, Wang Z. Establishment of a Biaxial Testing System for Characterization of Right Ventricle Viscoelasticity Under Physiological Loadings. Cardiovasc Eng Technol 2024:10.1007/s13239-024-00722-5. [PMID: 38468114 DOI: 10.1007/s13239-024-00722-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 02/19/2024] [Indexed: 03/13/2024]
Abstract
PURPOSE Prior studies have indicated an impact of cardiac muscle viscoelasticity on systolic and diastolic functions. However, the studies of ventricular free wall viscoelasticity, particularly for that of right ventricles (RV), are limited. Moreover, investigations on ventricular passive viscoelasticity have been restricted to large animals and there is a lack of data on rodent species. To fill this knowledge gap, this study aims to develop a biaxial tester that induces high-speed physiological deformations to characterize the passive viscoelasticity of rat RVs. METHODS The biaxial testing system was fabricated so that planar deformation of rat ventricle tissues at physiological strain rates was possible. The testing system was validated using isotropic polydimethylsiloxane (PDMS) sheets. Next, viscoelastic measurements were performed in healthy rat RV free walls by equibiaxial cyclic sinusoidal loadings and stress relaxation. RESULTS The biaxial tester's consistency, accuracy, and stability was confirmed from the PDMS samples measurements. Moreover, significant viscoelastic alterations of the RV were found between sub-physiological (0.1 Hz) and physiological frequencies (1-8 Hz). From hysteresis loop analysis, we found as the frequency increased, the elasticity and viscosity were increased in both directions. Interestingly, the ratio of storage energy to dissipated energy (Wd/Ws) remained constant at 0.1-5 Hz. We did not observe marked differences in healthy RV viscoelasticity between longitudinal and circumferential directions. CONCLUSION This work provides a new experimental tool to quantify the passive, biaxial viscoelasticity of ventricle free walls in both small and large animals. The dynamic mechanical tests showed frequency-dependent elastic and viscous behaviors of healthy rat RVs. But the ratio of dissipated energy to stored energy was maintained between frequencies. These findings offer novel baseline information on the passive viscoelasticity of healthy RVs in adult rats.
Collapse
Affiliation(s)
- Kellan Roth
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Wenqiang Liu
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
- Stanford Cardiovascular Institute, Stanford University, Stanford, CA, USA
| | - Kristen LeBar
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Matt Ahern
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Zhijie Wang
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA.
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
3
|
Barajas B, Kurtz IS, Waldman AJ, Schiffman JD. Stiffness and Oligomer Content Affect the Initial Adhesion of Staphylococcus aureus to Polydimethylsiloxane Gels. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37922414 DOI: 10.1021/acsami.3c11349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2023]
Abstract
The growing prevalence of methicillin-resistant Staphylococcus aureus (S. aureus) infections necessitates a greater understanding of their initial adhesion to medically relevant surfaces. In this study, the influence of the mechanical properties and oligomer content of polydimethylsiloxane (PDMS) gels on the initial attachment of Gram-positive S. aureus was explored. Small-amplitude oscillatory shear rheological measurements were conducted to verify that by altering the base to curing (B:C) ratio of the commonly used Sylgard 184 silicone elastomer kit (B:C ratios of 60:1, 40:1, 10:1, and 5:1), PDMS gels could be synthesized with Young's moduli across four distinct regimes: ultrasoft (15 kPa), soft (30 kPa), standard (400 kPa), and stiff (1500 kPa). These as-prepared gels (unextracted) were compared to gels prepared from the same B/C ratios that underwent Soxhlet extraction to remove any unreacted oligomers. While the Young's moduli of unextracted and extracted PDMS gels prepared from the same B:C ratio were statistically equivalent, the associated adhesion failure energy statistically decreased for the ultrasoft gels after extraction (from 25 to 8 J/mm2). The interactions of these eight well-characterized gels with bacteria were tested by using S. aureus SH1000, a commonly studied laboratory strain, as well as S. aureus ATCC 12600, which was isolated from a human lung infection. Increased S. aureus inactivation occurred only when the bacteria were incubated directly on top of the unextracted gels prepared at high B:C ratios (40:1 and 60:1), whereas none of the extracted gels (no unreacted oligomers) had significant levels of inactivated bacteria. S. aureus adhered the least to the stiffest extracted PDMS gels (no unreacted oligomers) and the most to soft, unextracted PDMS gels (with ∼17% unreacted oligomers). These findings suggest that both unreacted oligomers and Young's moduli are important material factors to consider when exploring the attachment behavior of Gram-positive S. aureus to hydrophobic elastomer gels.
Collapse
Affiliation(s)
- Brandon Barajas
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003-9303, United States
| | - Irene S Kurtz
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003-9303, United States
| | - Abraham J Waldman
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003-9303, United States
| | - Jessica D Schiffman
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003-9303, United States
| |
Collapse
|
4
|
Schoenborn S, Lorenz T, Kuo K, Fletcher DF, Woodruff MA, Pirola S, Allenby MC. Fluid-structure interactions of peripheral arteries using a coupled in silico and in vitro approach. Comput Biol Med 2023; 165:107474. [PMID: 37703711 DOI: 10.1016/j.compbiomed.2023.107474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/21/2023] [Accepted: 09/04/2023] [Indexed: 09/15/2023]
Abstract
Vascular compliance is considered both a cause and a consequence of cardiovascular disease and a significant factor in the mid- and long-term patency of vascular grafts. However, the biomechanical effects of localised changes in compliance cannot be satisfactorily studied with the available medical imaging technologies or surgical simulation materials. To address this unmet need, we developed a coupled silico-vitro platform which allows for the validation of numerical fluid-structure interaction results as a numerical model and physical prototype. This numerical one-way and two-way fluid-structure interaction study is based on a three-dimensional computer model of an idealised femoral artery which is validated against patient measurements derived from the literature. The numerical results are then compared with experimental values collected from compliant arterial phantoms via direct pressurisation and ring tensile testing. Phantoms within a compliance range of 1.4-68.0%/100 mmHg were fabricated via additive manufacturing and silicone casting, then mechanically characterised via ring tensile testing and optical analysis under direct pressurisation with moderately statistically significant differences in measured compliance ranging between 10 and 20% for the two methods. One-way fluid-structure interaction coupling underestimated arterial wall compliance by up to 14.7% compared with two-way coupled models. Overall, Solaris™ (Smooth-On) matched the compliance range of the numerical and in vivo patient models most closely out of the tested silicone materials. Our approach is promising for vascular applications where mechanical compliance is especially important, such as the study of diseases which commonly affect arterial wall stiffness, such as atherosclerosis, and the model-based design, surgical training, and optimisation of vascular prostheses.
Collapse
Affiliation(s)
- S Schoenborn
- BioMimetic Systems Engineering (BMSE) Lab, School of Chemical Engineering, University of Queensland (UQ), St Lucia, QLD, 4072, Australia; Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
| | - T Lorenz
- Institute of Textile Technology, RWTH Aachen University, 52074, Aachen, Germany
| | - K Kuo
- Institute of Textile Technology, RWTH Aachen University, 52074, Aachen, Germany
| | - D F Fletcher
- School of Chemical and Biomolecular Engineering, University of Sydney, Darlington, NSW, 2006, Australia
| | - M A Woodruff
- Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
| | - S Pirola
- BHF Centre of Research Excellence, Faculty of Medicine, Institute of Clinical Sciences, Imperial College London, South Kensington Campus, London, SW7 2AZ, United Kingdom; Department of Biomechanical Engineering, Faculty of Mechanical Engineering (3me), Delft University of Technology (TUD), Delft, the Netherlands
| | - M C Allenby
- BioMimetic Systems Engineering (BMSE) Lab, School of Chemical Engineering, University of Queensland (UQ), St Lucia, QLD, 4072, Australia; Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia.
| |
Collapse
|
5
|
Artico M, Roux C, Peruch F, Mingotaud AF, Montanier CY. Grafting of proteins onto polymeric surfaces: A synthesis and characterization challenge. Biotechnol Adv 2023; 64:108106. [PMID: 36738895 DOI: 10.1016/j.biotechadv.2023.108106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 01/26/2023] [Accepted: 01/30/2023] [Indexed: 02/05/2023]
Abstract
This review aims at answering the following question: how can a researcher be sure to succeed in grafting a protein onto a polymer surface? Even if protein immobilization on solid supports has been used industrially for a long time, hence enabling natural enzymes to serve as a powerful tool, emergence of new supports such as polymeric surfaces for the development of so-called intelligent materials requires new approaches. In this review, we introduce the challenges in grafting protein on synthetic polymers, mainly because compared to hard surfaces, polymers may be sensitive to various aqueous media, depending on the pH or reductive molecules, or may exhibit state transitions with temperature. Then, the specificity of grafting on synthetic polymers due to difference of chemical functions availability or difference of physical properties are summarized. We present next the various available routes to covalently bond the protein onto the polymeric substrates considering the functional groups coming from the monomers used during polymerization reaction or post-modification of the surfaces. We also focus our review on a major concern of grafting protein, which is avoiding the potential loss of function of the immobilized protein. Meanwhile, this review considers the different methods of characterization used to determine the grafting efficiency but also the behavior of enzymes once grafted. We finally dedicate the last part of this review to industrial application and future prospective, considering the sustainable processes based on green chemistry.
Collapse
Affiliation(s)
- M Artico
- Laboratory IMRCP, CNRS UMR 5623, University Paul Sabatier, Toulouse, France; TBI, Université de Toulouse, CNRS, INRAE, INSA, Toulouse, France
| | - C Roux
- Laboratory IMRCP, CNRS UMR 5623, University Paul Sabatier, Toulouse, France
| | - F Peruch
- Univ. Bordeaux, CNRS, Bordeaux INP, LCPO, UMR 5629, Pessac, France
| | - A-F Mingotaud
- Laboratory IMRCP, CNRS UMR 5623, University Paul Sabatier, Toulouse, France.
| | - C Y Montanier
- TBI, Université de Toulouse, CNRS, INRAE, INSA, Toulouse, France.
| |
Collapse
|
6
|
Campeau MA, Leask RL. Empagliflozin mitigates endothelial inflammation and attenuates endoplasmic reticulum stress signaling caused by sustained glycocalyx disruption. Sci Rep 2022; 12:12681. [PMID: 35879337 PMCID: PMC9314417 DOI: 10.1038/s41598-022-16763-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 07/14/2022] [Indexed: 11/09/2022] Open
Abstract
The disruption of the endothelial cell (EC) glycocalyx (GCX) leads to cellular dysfunction promoting inflammation and cardiovascular disease progression. Recent studies have shown that empagliflozin (EMPA; Jardiance), a sodium-glucose cotransporter 2 inhibitor used in the treatment of type 2 diabetes, can improve EC functions impacted by GCX disruption although the exact cellular mechanisms remain to be elucidated. In this study, the effect of EMPA on EC inflammatory response induced by sustained GCX disruption was investigated. Human aortic ECs were cultured under shear (10 dyne/cm2) for 24 h with or without sustained degradation of heparan sulfate (HS). HS degradation increased inflammatory cell adhesion to ECs. EMPA (50 μM) normalized adhesion levels under sustained HS degradation. Protein expressions of eNOS, phospho-eNOS Ser1177 and ICAM-1 remained unchanged between conditions. Transcriptome analysis revealed the induction of the unfolded protein response (UPR) through the increased expression of ATF3, ATF4, DDIT3 (CHOP), EIF2AK3 (PERK), HSPA5 (Grp78), PPP1R15A (GADD34) and TRIB3 which was in part downregulated by EMPA. mRNA and protein expression of thioredoxin interacting protein (TXNIP) was also downregulated by EMPA. Mitigation of oxidative stress with N-Acetyl-L-cysteine resulted in similar reduction in inflammatory cell adhesion compared to EMPA which could indicate a potential mechanism by which EMPA normalized the inflammatory response. In conclusion, this study demonstrated the potential of EMPA to resolve the inflammatory response of ECs caused by sustained GCX disruption while altering UPR signaling under endoplasmic reticulum stress.
Collapse
Affiliation(s)
| | - Richard L Leask
- Department of Chemical Engineering, McGill University, Montreal, QC, Canada. .,McGill University Health Centre, Montreal, QC, Canada.
| |
Collapse
|
7
|
Bernini M, Colombo M, Dunlop C, Hellmuth R, Chiastra C, Ronan W, Vaughan TJ. Oversizing of self-expanding nitinol vascular stents – A biomechanical investigation in the superficial femoral artery. J Mech Behav Biomed Mater 2022; 132:105259. [DOI: 10.1016/j.jmbbm.2022.105259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 04/20/2022] [Accepted: 04/29/2022] [Indexed: 10/18/2022]
|
8
|
Aydemir D, Dogru S, Alaca BE, Ulusu NN. Impact of the surface modifications and cell culture techniques on the biomechanical properties of PDMS in relation to cell growth behavior. INT J POLYM MATER PO 2021. [DOI: 10.1080/00914037.2021.1919670] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Duygu Aydemir
- Biochemistry Department, Koç University School of Medicine, Sariyer, Turkey
- Koç University Research Center for Translational Medicine (KUTTAM), Sariyer, Turkey
| | - Sedat Dogru
- Department of Mechanical Engineering, Koç University, Sariyer, Turkey
| | - B. Erdem Alaca
- Department of Mechanical Engineering, Koç University, Sariyer, Turkey
- Surface Science and Technology Center, KUYTAM, Koç University, Sariyer, Turkey
| | - Nuriye Nuray Ulusu
- Biochemistry Department, Koç University School of Medicine, Sariyer, Turkey
- Koç University Research Center for Translational Medicine (KUTTAM), Sariyer, Turkey
| |
Collapse
|
9
|
Kim JH, Chhai P, Rhee K. Development and characterization of viscoelastic polydimethylsiloxane phantoms for simulating arterial wall motion. Med Eng Phys 2021; 91:12-18. [PMID: 34074461 DOI: 10.1016/j.medengphy.2021.03.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 03/21/2021] [Accepted: 03/23/2021] [Indexed: 11/17/2022]
Abstract
Arterial wall viscoelasticity is likely to be a good diagnostic indicator of vascular disease, but only a few studies on the assessment of wall viscosity have been performed. Artery phantoms are manufactured using polydimethylsiloxane (PDMS) to simulate the viscoelastic characteristics of the artery wall, which depends on the wall tissue composition and progression of atherosclerosis. The viscoelastic property of PDMS is controlled by adjusting the mixture ratio of resin, curing agent, and pure silicone oil. The pressure and diameter waveforms of the artery phantom were measured to estimate the wall viscoelasticity. Elasticity is assessed using the diameter distention over the pulse pressure, and the viscosity is evaluated using the energy dissipation ratio of the pressure-diameter curve and the phase lag between the first harmonics of pressure and diameter waveforms (DP1). PDMS phantoms with resin-to-curing-agent ratios of 20:1 and 25:1 show viscoelastic characteristics similar to those of young and old human carotid arteries, respectively. Adding pure silicone oil further softens the silicone elastomer while decreasing its viscosity. The phantoms with 10:1:5 and 10:1:8 mixture ratios (resin: curing agent: silicone oil) show elasticity similar to that of the 20:1:0 and 25:1:0 ratios, respectively, albeit with a noticeable decrease in viscosity. An abrupt decrease in the phase lag (DP1) was found near the interface of the arterial phantom with different mixture ratios (20:1:0 and 10:1:5), while the change in diameter distension was negligible. DP1 may be a new index to differentiate wall tissues with similar elastic properties but different viscous behavior. The pressure diameter curve and DP1 of the phantom simulating the atherosclerosis wall can be compared with patient data and applied to clinical evaluation of plaque viscoelasticity. Computational analysis of arterial wall motion was performed using a standard linear viscoelastic model. The model parameters were determined from the measured pressure-diameter relationship, and the arterial wall motions of phantoms with different viscoelastic properties were successfully simulated. The computational model may provide a useful insight into the changes of arterial viscoelasticity caused by pathogenic wall degeneration.
Collapse
Affiliation(s)
- Je Hyun Kim
- Department of Mechanical Engineering, Myongji University, 116 Myongji-ro, Cheoin-gu, Yongin-si, Gyeonggi-do 17058, South Korea
| | - Pengsrorn Chhai
- Department of Mechanical Engineering, Myongji University, 116 Myongji-ro, Cheoin-gu, Yongin-si, Gyeonggi-do 17058, South Korea
| | - Kyehan Rhee
- Department of Mechanical Engineering, Myongji University, 116 Myongji-ro, Cheoin-gu, Yongin-si, Gyeonggi-do 17058, South Korea.
| |
Collapse
|
10
|
Alhudaithy S, Abdulmalik S, Kumbar SG, Hoshino K. Design, Fabrication, and Validation of a Petri Dish-Compatible PDMS Bioreactor for the Tensile Stimulation and Characterization of Microtissues. MICROMACHINES 2020; 11:E892. [PMID: 32993158 PMCID: PMC7650815 DOI: 10.3390/mi11100892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 09/11/2020] [Accepted: 09/24/2020] [Indexed: 11/16/2022]
Abstract
In this paper, we report on a novel biocompatible micromechanical bioreactor (actuator and sensor) designed for the in situ manipulation and characterization of live microtissues. The purpose of this study was to develop and validate an application-targeted sterile bioreactor that is accessible, inexpensive, adjustable, and easily fabricated. Our method relies on a simple polydimethylsiloxane (PDMS) molding technique for fabrication and is compatible with commonly-used laboratory equipment and materials. Our unique design includes a flexible thin membrane that allows for the transfer of an external actuation into the PDMS beam-based actuator and sensor placed inside a conventional 35 mm cell culture Petri dish. Through computational analysis followed by experimental testing, we demonstrated its functionality, accuracy, sensitivity, and tunable operating range. Through time-course testing, the actuator delivered strains of over 20% to biodegradable electrospun poly (D, L-lactide-co-glycolide) (PLGA) 85:15 non-aligned nanofibers (~91 µm thick). At the same time, the sensor was able to characterize time-course changes in Young's modulus (down to 10-150 kPa), induced by an application of isopropyl alcohol (IPA). Furthermore, the actuator delivered strains of up to 4% to PDMS monolayers (~30 µm thick), simultaneously characterizing their elastic modulus up to ~2.2 MPa. The platform repeatedly applied dynamic (0.23 Hz) tensile stimuli to live Human Dermal Fibroblast (HDF) cells for 12 hours (h) and recorded the cellular reorientation towards two angle regimes, with averages of -58.85° and +56.02°. The device biocompatibility with live cells was demonstrated for one week, with no signs of cytotoxicity. We can conclude that our PDMS bioreactor is advantageous for low-cost tissue/cell culture micromanipulation studies involving mechanical actuation and characterization. Our device eliminates the need for an expensive experimental setup for cell micromanipulation, increasing the ease of live-cell manipulation studies by providing an affordable way of conducting high-throughput experiments without the need to open the Petri dish, reducing manual handling, cross-contamination, supplies, and costs. The device design, material, and methods allow the user to define the operational range based on their targeted samples/application.
Collapse
Affiliation(s)
- Soliman Alhudaithy
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (S.A.); (S.A.); (S.K.)
- Department of Biomedical Technology, King Saud University, Riyadh 12372, Saudi Arabia
| | - Sama Abdulmalik
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (S.A.); (S.A.); (S.K.)
- Department of Orthopedic Surgery, University of Connecticut Health, Farmington, CT 06030, USA
| | - Sangamesh G. Kumbar
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (S.A.); (S.A.); (S.K.)
- Department of Orthopedic Surgery, University of Connecticut Health, Farmington, CT 06030, USA
- Department of Materials Science and Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Kazunori Hoshino
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (S.A.); (S.A.); (S.K.)
| |
Collapse
|
11
|
3D Printed Silicone Meniscus Implants: Influence of the 3D Printing Process on Properties of Silicone Implants. Polymers (Basel) 2020; 12:polym12092136. [PMID: 32962059 PMCID: PMC7570003 DOI: 10.3390/polym12092136] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 09/02/2020] [Accepted: 09/08/2020] [Indexed: 01/14/2023] Open
Abstract
Osteoarthritis of the knee with meniscal pathologies is a severe meniscal pathology suffered by the aging population worldwide. However, conventional meniscal substitutes are not 3D-printable and lack the customizability of 3D printed implants and are not mechanically robust enough for human implantation. Similarly, 3D printed hydrogel scaffolds suffer from drawbacks of being mechanically weak and as a result patients are unable to execute immediate post-surgical weight-bearing ambulation and rehabilitation. To solve this problem, we have developed a 3D silicone meniscus implant which is (1) cytocompatible, (2) resistant to cyclic loading and mechanically similar to native meniscus, and (3) directly 3D printable. The main focus of this study is to determine whether the purity, composition, structure, dimensions and mechanical properties of silicone implants are affected by the use of a custom-made in-house 3D-printer. We have used the phosphate buffer saline (PBS) absorption test, Fourier transform infrared (FTIR) spectroscopy, surface profilometry, thermo-gravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), differential scanning calorimetry (DSC), and scanning electron microscopy (SEM) to effectively assess and compare material properties between molded and 3D printed silicone samples.
Collapse
|
12
|
Müller S, Ueda M, Isoshima T, Ushida T, Ito Y. Stretching of fibroblast cells on micropatterned gelatin on silicone elastomer. J Mater Chem B 2020; 8:416-425. [DOI: 10.1039/c9tb02203a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Micropatterned gelatin was formed on the silicone elastomer surface. The micropattern enabled cell alignment, regulation of the cell shape, and endowed the cells with resistance against mechanical stress.
Collapse
Affiliation(s)
- Stefan Müller
- Emergent Bioengineering Materials Research Team
- RIKEN Center for Emergent Matter Science
- Saitama
- Japan
- Graduate School of Medicine
| | - Motoki Ueda
- Emergent Bioengineering Materials Research Team
- RIKEN Center for Emergent Matter Science
- Saitama
- Japan
- Nano Medical Engineering Laboratory
| | - Takashi Isoshima
- Nano Medical Engineering Laboratory
- RIKEN Cluster for Pioneering Research
- Saitama
- Japan
| | - Takashi Ushida
- Graduate School of Medicine
- The University of Tokyo
- Tokyo
- Japan
| | - Yoshihiro Ito
- Emergent Bioengineering Materials Research Team
- RIKEN Center for Emergent Matter Science
- Saitama
- Japan
- Nano Medical Engineering Laboratory
| |
Collapse
|
13
|
Affiliation(s)
- Yoshihiro Ito
- Nano Medical Engineering Laboratory, RIKEN Cluster for Pioneering Research, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
- Emergent Bioengineering Materials Research Team, RIKEN Center for Emergent Matter Science, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
| |
Collapse
|