1
|
Kocaoglu M, Lang SM, Ta H, Moore RA, Pednekar A. Noncontrast free-breathing ECG-gated 3D balanced steady-state free precession in congenital heart disease and aortopathy evaluation. Pediatr Radiol 2024; 54:1661-1673. [PMID: 39164501 DOI: 10.1007/s00247-024-06024-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/31/2024] [Accepted: 08/01/2024] [Indexed: 08/22/2024]
Abstract
BACKGROUND High-fidelity cardiac magnetic resonance (MR) imaging plays a pivotal role in the surveillance of congenital heart disease (CHD) and aortopathy. OBJECTIVE We aimed to evaluate the quality and accuracy of free breathing, ECG-gated noncontrast three-dimensional (3D) balanced steady-state free precession (bSSFP) in cases of CHDs and aortopathies using contrast-enhanced 3D bSSFP as a reference. We also used one of our routinely used non-ECG-gated 2D-single-shot (SSh) bSSFP sequence as an adjunct to noncontrast 3D bSSFP. MATERIALS AND METHODS Institutional review board approval was obtained to perform a systematic retrospective analysis of image quality and vascular measurements. Patients with CHD and aortopathy, who were undergoing clinically indicated contrast-enhanced 3D bSSFP, were prospectively identified to also undergo additional noncontrast 3D bSSFP and 2D SSh bSSFP imaging as part of a clinical quality improvement initiative aimed at reducing the use of contrast when feasible. Two readers, blinded to each other's evaluations, graded image quality on a 5-point Likert scale and performed vascular measurements in separate sessions for both 3D bSSFP images. They also reported the visibility of various mediastinal great vessels on 2D SSh bSSFP images. Raw agreement, the weighted kappa statistic, and intra-class correlation coefficients (ICCs) were computed to assess the consistency and agreement between the two readers. Comparative analysis of noncontrast and contrast-enhanced 3D bSSFP imaging was performed in adult and pediatric patients using a two-sided paired t-test and Bland-Altman analysis. A P-value < 0.05 was considered significant for all inference testing. RESULTS A total of 29 patients (17 males, median age 20.3 years, interquartile range (IQR) 12.5, age range 7-39 years), including 11 pediatric patients under the age of 18 years (6 males, median age 14.5 years, IQR 4.0, age range 7-17 years), underwent retrospective analysis. The overall image quality score for contrast-enhanced 3D bSSFP was significantly higher (P < 0.0001) than that of noncontrast 3D bSSFP for both all subjects (4.4 ± 0.2, range 4.0-4.9 vs 3.7 ± 0.4, range 3.1-4.7) and only pediatric subjects (4.3 ± 0.3, range 4.0-4.9 vs 3.6 ± 0.5, range 3.1-4.4). By combining noncontrast 3D bSSFP and 2D bSSFP, reader 1 and reader 2 rated 423 and 420 vessels diagnostic, respectively, in a total of 435 vessel segments. All landmarks showed similar mean vessel diameters without significant differences between noncontrast and contrast-enhanced 3D bSSFP MR angiography (r = 0.99, bias -0.31 mm, 95% limits of agreement -2.04 mm to 1.43 mm). CONCLUSIONS Although contrast-enhanced images had better overall image quality, an imaging protocol consisting of noncontrast 2D SSh bSSFP and 3D bSSFP whole-chest images provides diagnostically adequate image quality, and accurate vascular measurements, comparable to free-breathing contrast-enhanced 3D bSSFP in both children and adults with CHD and aortopathies.
Collapse
Affiliation(s)
- Murat Kocaoglu
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC 5031, 3333 Burnet Ave, Cincinnati, OH, 45229, USA.
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| | - Sean M Lang
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Hieu Ta
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Ryan A Moore
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Amol Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC 5031, 3333 Burnet Ave, Cincinnati, OH, 45229, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
2
|
Dawes TJW, Woodham V, Sharkey E, McEwan A, Derrick G, Muthurangu V, Moledina S, Hepburn L. Predicting Peri-Operative Cardiorespiratory Adverse Events in Children with Idiopathic Pulmonary Arterial Hypertension Undergoing Cardiac Catheterization Using Echocardiography: A Cohort Study. Pediatr Cardiol 2024:10.1007/s00246-024-03447-3. [PMID: 38512488 DOI: 10.1007/s00246-024-03447-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Accepted: 02/07/2024] [Indexed: 03/23/2024]
Abstract
General anesthesia in children with idiopathic pulmonary arterial hypertension (PAH) carries an increased risk of peri-operative cardiorespiratory complications though risk stratifying individual children pre-operatively remains difficult. We report the incidence and echocardiographic risk factors for adverse events in children with PAH undergoing general anesthesia for cardiac catheterization. Echocardiographic, hemodynamic, and adverse event data from consecutive PAH patients are reported. A multivariable predictive model was developed from echocardiographic variables identified by Bayesian univariable logistic regression. Model performance was reported by area under the curve for receiver operating characteristics (AUCroc) and precision/recall (AUCpr) and a pre-operative scoring system derived (0-100). Ninety-three children underwent 158 cardiac catheterizations with mean age 8.8 ± 4.6 years. Adverse events (n = 42) occurred in 15 patients (16%) during 16 catheterizations (10%) including cardiopulmonary resuscitation (n = 5, 3%), electrocardiographic changes (n = 3, 2%), significant hypotension (n = 2, 1%), stridor (n = 1, 1%), and death (n = 2, 1%). A multivariable model (age, right ventricular dysfunction, and dilatation, pulmonary and tricuspid regurgitation severity, and maximal velocity) was highly predictive of adverse events (AUCroc 0.86, 95% CI 0.75 to 1.00; AUCpr 0.68, 95% CI 0.50 to 0.91; baseline AUCpr 0.10). Pre-operative risk scores were higher in those who had a subsequent adverse event (median 47, IQR 43 to 53) than in those who did not (median 23, IQR 15 to 33). Pre-operative echocardiography informs the risk of peri-operative adverse events and may therefore be useful both for consent and multi-disciplinary care planning.
Collapse
Affiliation(s)
- Timothy J W Dawes
- Department of Anaesthesia, Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 1LE, UK.
- UCL Institute of Cardiovascular Science, University College London, London, UK.
| | - Valentine Woodham
- Department of Anaesthesia, Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 1LE, UK
| | - Emma Sharkey
- Department of Anaesthesia, Evelina London Children's Hospital, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - Angus McEwan
- Department of Anaesthesia, Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 1LE, UK
| | - Graham Derrick
- UCL Institute of Cardiovascular Science, University College London, London, UK
- Department of Paediatric Cardiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Vivek Muthurangu
- UCL Institute of Cardiovascular Science, University College London, London, UK
| | - Shahin Moledina
- UCL Institute of Cardiovascular Science, University College London, London, UK
- National Paediatric Pulmonary Hypertension Service UK, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Lucy Hepburn
- Department of Anaesthesia, Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 1LE, UK
| |
Collapse
|
3
|
Kocaoglu M, Pednekar A, Fleck RJ, Dillman JR. Cardiothoracic Magnetic Resonance Angiography. Curr Probl Diagn Radiol 2024; 53:154-165. [PMID: 37891088 DOI: 10.1067/j.cpradiol.2023.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 09/01/2023] [Accepted: 10/18/2023] [Indexed: 10/29/2023]
Abstract
Catheter-based angiography is regarded as the clinical reference imaging technique for vessel imaging; however, it is invasive and is currently used for intervention or physiologic measurements. Contrast enhanced magnetic resonance angiography (MRA) with gadolinium-based contrast agents can be performed as a three-dimensional (3D) MRA or as a time resolved 3D (4D) MRA without physiologic synchronization, in which case cardiac and respiratory motion may blur the edges of the vessels and cardiac chambers. Ferumoxytol has recently been a popular contrast agent for MRA in patients with chronic renal failure. Noncontrast 3D MRA with ECG gating and respiratory navigation are safe and accurate noninvasive cross-sectional imaging techniques for the visualization of great vessels of the heart and coronary arteries in a variety of cardiovascular disorders including complex congenital heart diseases. Noncontrast flow dependent MRA techniques such as time of flight, phase contrast, and black-blood MRA techniques can be used as complementary or primary techniques. Here we review both conventional and relatively new contrast enhanced and non-contrast enhanced MRA techniques including ferumoxytol enhanced MRA, and bright-blood and water-fat separation based noncontrast 3D MRA techniques.
Collapse
Affiliation(s)
- Murat Kocaoglu
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| | - Amol Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Robert J Fleck
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
4
|
Lilyasari O, Goo HW, Siripornpitak S, Abdul Latiff H, Ota H, Caro-Dominguez P. Multimodality diagnostic imaging for anomalous pulmonary venous connections: a pictorial essay. Pediatr Radiol 2023; 53:2120-2133. [PMID: 37202498 DOI: 10.1007/s00247-023-05660-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/28/2023] [Accepted: 03/29/2023] [Indexed: 05/20/2023]
Abstract
Anomalous pulmonary venous connections represent a heterogeneous group of congenital heart diseases in which a part or all pulmonary venous flow drains directly or indirectly into the right atrium. Clinically, anomalous pulmonary venous connections may be silent or have variable consequences, including neonatal cyanosis, volume overload and pulmonary arterial hypertension due to the left-to-right shunt. Anomalous pulmonary venous connections are frequently associated with other congenital cardiac defects and their accurate diagnosis is crucial for treatment planning. Therefore, multimodality diagnostic imaging, comprising a combination (but not all) of echocardiography, cardiac catheterization, cardiothoracic computed tomography and cardiac magnetic resonance imaging, helps identify potential blind spots relevant to each imaging modality before treatment and achieve optimal management and monitoring. For the same reasons, diagnostic imaging evaluation using a multimodality fashion should be used after treatment. Finally, those interpreting the images should be familiar with the various surgical approaches used to repair anomalous pulmonary venous connections and the common postoperative complications.
Collapse
Affiliation(s)
- Oktavia Lilyasari
- Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Indonesia, National Cardiovascular Center Harapan Kita, Jakarta, Indonesia
| | - Hyun Woo Goo
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Republic of Korea.
| | - Suvipaporn Siripornpitak
- Department of Diagnostic and Therapeutic Radiology, Mahidol University Faculty of Medicine, Ramathibodi Hospital, Bangkok, Thailand
| | - Haifa Abdul Latiff
- Pediatric and Congenital Heart Centre, Institut Jantung Negara, Kuala Lumpur, Malaysia
| | - Hideki Ota
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Pablo Caro-Dominguez
- Unidad de Radiologia Pediatrica, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Seville, Spain
| |
Collapse
|
5
|
Mesropyan N, Isaak A, Dabir D, Hart C, Faron A, Endler C, Kravchenko D, Katemann C, Pieper CC, Kuetting D, Attenberger UI, Luetkens JA. Free-breathing high resolution modified Dixon steady-state angiography with compressed sensing for the assessment of the thoracic vasculature in pediatric patients with congenital heart disease. J Cardiovasc Magn Reson 2021; 23:117. [PMID: 34689811 PMCID: PMC8543883 DOI: 10.1186/s12968-021-00810-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 08/30/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance angiography (CMRA) is a non-invasive imaging modality of choice in pediatric patients with congenital heart disease (CHD). This study was aimed to evaluate the diagnostic utility of a respiratory- and electrocardiogram-gated steady-state CMRA with modified Dixon (mDixon) fat suppression technique and compressed sensing in comparison to standard first-pass CMRA in pediatric patients with CHD at 3 T. METHODS In this retrospective single center study, pediatric CHD patients who underwent CMR with first-pass CMRA followed by mDixon steady-state CMRA at 3 T were analyzed. Image quality using a Likert scale from 5 (excellent) to 1 (non-diagnostic) and quality of fat suppression were assessed in consensus by two readers. Blood-to-tissue contrast and quantitative measurements of the thoracic vasculature were assessed separately by two readers. CMRA images were reevaluated by two readers for additional findings, which could be identified only on either one of the CMRA types. Paired Student t test, Wilcoxon test, and intraclass correlation coefficients (ICCs) were used for statistical analysis. RESULTS 32 patients with CHD (3.3 ± 1.7 years, 13 female) were included. Overall image quality of steady-state mDixon CMRA was higher compared to first-pass CMRA (4.5 ± 0.5 vs. 3.3 ± 0.5; P < 0.001). Blood-to-tissue contrast ratio of steady-state mDixon CMRA was comparable to first-pass CMRA (7.85 ± 4.75 vs. 6.35 ± 2.23; P = 0.133). Fat suppression of steady-state mDixon CMRA was perfect in 30/32 (94%) cases. Vessel diameters were greater in first-pass CMRA compared to steady-state mDixon CMRA with the greatest differences at the level of pulmonary arteries and veins (e.g., right pulmonary artery for reader 1: 10.4 ± 2.4 vs. 9.9 ± 2.3 mm, P < 0.001). Interobserver agreement was higher for steady-state mDixon CMRA for all measurements compared to first-pass CMRA (ICCs > 0.92). In 9/32 (28%) patients, 10 additional findings were identified on mDixon steady-state CMRA (e.g., partial anomalous venous return, abnormalities of coronary arteries, subclavian artery stenosis), which were not depicted using first-pass CMRA. CONCLUSIONS Steady-state mDixon CMRA offers a robust fat suppression, a high image quality, and diagnostic utility for the assessment of the thoracic vasculature in pediatric CHD patients.
Collapse
Affiliation(s)
- Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | - Darius Dabir
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | - Christopher Hart
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Department of Pediatric Cardiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Anton Faron
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | - Christoph Endler
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | - Dmitrij Kravchenko
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | | | - Claus C Pieper
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany
| | - Ulrike I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg- Campus 1, 53127, Bonn, Germany.
- Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127, Bonn, Germany.
| |
Collapse
|
6
|
Huf VI, Fellner C, Wohlgemuth WA, Stroszczynski C, Schmidt M, Forman C, Wetzl J, Uller W. Fast TWIST with iterative reconstruction improves diagnostic accuracy of AVM of the hand. Sci Rep 2020; 10:16355. [PMID: 33004952 PMCID: PMC7529883 DOI: 10.1038/s41598-020-73331-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Accepted: 09/14/2020] [Indexed: 11/08/2022] Open
Abstract
Very high temporal and spatial resolution is mandatory for the diagnosis of arteriovenous malformations (AVM) of the hand. Until now, magnetic resonance imaging (MRI) has not fulfilled both requirements simultaneously. This study presents how the combination of a very fast TWIST MRI (time-resolved angiography with interleaved stochastic trajectories) sequence and iterative reconstructions optimizes temporal as well as spatial resolution. 11 patients were examined at a 3-T MRI scanner with two different TWIST protocols: the standard and the study protocol, acquiring a data set every 5.57 s and 1.44 s respectively. The study data was retrospectively iteratively reconstructed with different regularization factors (0.001, 0.002, 0.004, 0.008). Results were compared using the sign-test. P-values < 0.05 were regarded statistically significant. With a low amount of contrast medium, the temporal resolution of the study protocol enabled the differentiation of arteries from veins in all patients whereas the signal-to-noise ratio (SNR) deteriorated. Depending on the regularization factors, SNR, delineation of arterial feeders and non-involved hand and interdigital arteries, as well as artefact levels varied. Overall, iterative reconstruction with regularization factor 0.004 achieved the best results, consequently showing the ability of MRI as a reliable diagnostic method in AVMs of the hand.
Collapse
Affiliation(s)
- Veronika I Huf
- Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany.
| | - Claudia Fellner
- Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany
| | - Walter A Wohlgemuth
- Interdisciplinary Center for Vascular Anomalies, University Clinic and Polyclinic of Radiology, University Hospital Halle, 06120, Halle (Saale), Germany
| | | | | | | | - Jens Wetzl
- Siemens Healthcare, 91052, Erlangen, Germany
| | - Wibke Uller
- Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany
| |
Collapse
|
7
|
Ciancarella P, Ciliberti P, Santangelo TP, Secchi F, Stagnaro N, Secinaro A. Noninvasive imaging of congenital cardiovascular defects. Radiol Med 2020; 125:1167-1185. [PMID: 32955650 DOI: 10.1007/s11547-020-01284-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 09/03/2020] [Indexed: 12/19/2022]
Abstract
Advances in the treatment have drastically increased the survival rate of congenital heart disease (CHD) patients. Therefore, the prevalence of these patients is growing. Imaging plays a crucial role in the diagnosis and management of this population as a key component of patient care at all stages, especially in those patients who survived into adulthood. Over the last decades, noninvasive imaging techniques, such as cardiac magnetic resonance (CMR) and cardiac computed tomography (CCT), progressively increased their clinical relevance, reaching stronger levels of accuracy and indications in the clinical surveillance of CHD. The current review highlights the main technical aspects and clinical applications of CMR and CCT in the setting of congenital cardiovascular abnormalities, aiming to address a state-of-the-art guidance to every physician and cardiac imager not routinely involved in the field.
Collapse
Affiliation(s)
- Paolo Ciancarella
- Department of Imaging, Advanced Cardiovascular Imaging Unit, Bambino Gesù Children's Hospital, IRCCS, Piazza S. Onofrio 4, 00165, Rome, Italy
| | - Paolo Ciliberti
- Pediatric Cardiology and Pediatric Cardiac Surgery Department, Bambino Gesù Children's Hospital IRCSS, Rome, Italy
| | - Teresa Pia Santangelo
- Department of Imaging, Advanced Cardiovascular Imaging Unit, Bambino Gesù Children's Hospital, IRCCS, Piazza S. Onofrio 4, 00165, Rome, Italy
| | - Francesco Secchi
- Radiology Unit, IRCCS Policlinico San Donato, San Donato Milanese, Italy.,Department of Biomedical Sciences for Health, Università degli Studi di Milano, San Donato Milanese, Italy
| | - Nicola Stagnaro
- Radiology Unit, IRCCS Istituto Giannina Gaslini, Genoa, Italy
| | - Aurelio Secinaro
- Department of Imaging, Advanced Cardiovascular Imaging Unit, Bambino Gesù Children's Hospital, IRCCS, Piazza S. Onofrio 4, 00165, Rome, Italy.
| |
Collapse
|
8
|
Sin D, McLennan G, Rengier F, Haddadin I, Heresi GA, Bartholomew JR, Fink MA, Thompson D, Partovi S. Acute pulmonary embolism multimodality imaging prior to endovascular therapy. Int J Cardiovasc Imaging 2020; 37:343-358. [PMID: 32862293 PMCID: PMC7456521 DOI: 10.1007/s10554-020-01980-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 08/19/2020] [Indexed: 12/15/2022]
Abstract
The manuscript discusses the application of CT pulmonary angiography, ventilation–perfusion scan, and magnetic resonance angiography to detect acute pulmonary embolism and to plan endovascular therapy. CT pulmonary angiography offers high accuracy, speed of acquisition, and widespread availability when applied to acute pulmonary embolism detection. This imaging modality also aids the planning of endovascular therapy by visualizing the number and distribution of emboli, determining ideal intra-procedural catheter position for treatment, and signs of right heart strain. Ventilation–perfusion scan and magnetic resonance angiography with and without contrast enhancement can also aid in the detection and pre-procedural planning of endovascular therapy in patients who are not candidates for CT pulmonary angiography.
Collapse
Affiliation(s)
- David Sin
- Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA
| | - Gordon McLennan
- Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA
| | - Fabian Rengier
- Section of Emergency Radiology, Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Ihab Haddadin
- Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA
| | - Gustavo A Heresi
- Department of Pulmonary and Critical Care Medicine, Respiratory Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA
| | - John R Bartholomew
- Section of Vascular Medicine, Heart and Vascular Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA
| | - Matthias A Fink
- Section of Emergency Radiology, Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Dustin Thompson
- Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA
| | - Sasan Partovi
- Section of Interventional Radiology, Imaging Institute, Cleveland Clinic Main Campus, Cleveland, OH, USA.
| |
Collapse
|
9
|
Pennig L, Wagner A, Weiss K, Lennartz S, Grunz JP, Maintz D, Laukamp KR, Hickethier T, Naehle CP, Bunck AC, Doerner J. Imaging of the pulmonary vasculature in congenital heart disease without gadolinium contrast: Intraindividual comparison of a novel Compressed SENSE accelerated 3D modified REACT with 4D contrast-enhanced magnetic resonance angiography. J Cardiovasc Magn Reson 2020; 22:8. [PMID: 31969137 PMCID: PMC6977250 DOI: 10.1186/s12968-019-0591-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 12/05/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Patients with Congenital heart disease (CHD) require repetitive imaging of the pulmonary vasculature throughout their life. In this study, we compared a novel Compressed SENSE accelerated (factor 9) electrocardiogram (ECG)- and respiratory-triggered 3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT-non-contrast-enhanced magnetic resonance angiography (modified REACT-non-CE-MRA)) with standard non-ECG-triggered time-resolved 4D CE-MRA for imaging of the pulmonary arteries and veins in patients with CHD. METHODS This retrospective analysis of 25 patients (June 2018-April 2019) with known or suspected CHD was independently conducted by two radiologists executing measurements on modified REACT-non-CE-MRA and 4D CE-MRA on seven dedicated points (inner edge): Main pulmonary artery (MPA), right and left pulmonary artery, right superior and inferior pulmonary vein, left superior (LSPV) and inferior pulmonary vein. Image quality for arteries and veins was evaluated on a four-point scale in consensus. RESULTS Twenty-three of the 25 included patients presented a CHD. There was a high interobserver agreement for both methods of imaging at the pulmonary arteries (ICC ≥ 0.96); at the pulmonary veins, modified REACT-non-CE-MRA showed a slightly higher agreement, pronounced at LSPV (ICC 0.946 vs. 0.895). Measurements in 4D CE-MRA showed higher diameter values compared to modified REACT-non-CE-MRA, at the pulmonary arteries reaching significant difference (e.g. MPA: mean 0.408 mm, p = 0.002). Modified REACT-non-CE-MRA (average acquisition time 07:01 ± 02:44 min) showed significant better image quality than 4D CE-MRA at the pulmonary arteries (3.84 vs. 3.32, p < 0.001) and veins (3.32 vs. 2.72, p = 0.015). CONCLUSIONS Compressed SENSE accelerated (factor 9) ECG- and respiratory-triggered 3D modified REACT-non-CE-MRA allows for reliable and fast imaging of the pulmonary arteries and veins with higher image quality and slightly higher interobserver agreement than 4D CE-MRA without contrast agent and associated disadvantages. Therefore, it represents a clinically suitable technique for patients requiring repetitive imaging of the pulmonary vasculature, e.g. patients with CHD.
Collapse
Affiliation(s)
- Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | - Anton Wagner
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | | | - Simon Lennartz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
- Else Kröner Forschungskolleg Clonal Evolution in Cancer, University Hospital Cologne, Weyertal 115b, 50931 Cologne, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | - Kai Roman Laukamp
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | - Tilman Hickethier
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | - Claas Philip Naehle
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | - Alexander Christian Bunck
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| | - Jonas Doerner
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany
| |
Collapse
|
10
|
Krupickova S, Vazquez-Garcia L, Obeidat M, Banya W, DiSalvo G, Ghez O, Michielon G, Castellano I, Rubens M, Semple T, Nicol E, Slavik Z, Rigby ML, Fraisse A. Accuracy of computed tomography in detection of great vessel stenosis or hypoplasia before superior bidirectional cavopulmonary connection: Comparison with cardiac catheterization and surgical findings. Arch Cardiovasc Dis 2019; 112:12-21. [DOI: 10.1016/j.acvd.2018.04.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 02/11/2018] [Accepted: 04/04/2018] [Indexed: 11/30/2022]
|
11
|
Steeden JA, Kowalik GT, Tann O, Hughes M, Mortensen KH, Muthurangu V. Real-time assessment of right and left ventricular volumes and function in children using high spatiotemporal resolution spiral bSSFP with compressed sensing. J Cardiovasc Magn Reson 2018; 20:79. [PMID: 30518390 PMCID: PMC6282387 DOI: 10.1186/s12968-018-0500-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 10/23/2018] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Real-time cardiovascular magnetic resonance (CMR) assessment of ventricular volumes and function enables data acquisition during free-breathing. The requirement for high spatiotemporal resolution in children necessitates the use of highly accelerated imaging techniques. METHODS A novel real-time balanced steady state free precession (bSSFP) spiral sequence reconstructed using Compressed Sensing (CS) was prospectively validated against the breath-hold clinical standard for assessment of ventricular volumes in 60 children with congenital heart disease. Qualitative image scoring, quantitative image quality, as well as evaluation of biventricular volumes was performed. Standard BH and real-time measures were compared using the paired t-test and agreement for volumetric measures were evaluated using Bland Altman analysis. RESULTS Acquisition time for the entire short axis stack (~ 13 slices) using the spiral real-time technique was ~ 20 s, compared to ~ 348 s for the standard breath hold technique. Qualitative scores reflected more residual aliasing artefact (p < 0.001) and lower edge definition (p < 0.001) in spiral real-time images than standard breath hold images, with lower quantitative edge sharpness and estimates of image contrast (p < 0.001). There was a small but statistically significant (p < 0.05) overestimation of left ventricular (LV) end-systolic volume (1.0 ± 3.5 mL), and underestimation of LV end-diastolic volume (- 1.7 ± 4.6 mL), LV stroke volume (- 2.6 ± 4.8 mL) and LV ejection fraction (- 1.5 ± 3.0%) using the real-time technique. We also observed a small underestimation of right ventricular stroke volume (- 1.8 ± 4.9 mL) and ejection fraction (- 1.4 ± 3.7%) using the real-time imaging technique. No difference in inter-observer or intra-observer variability were observed between the BH and real-time sequences. CONCLUSIONS Real-time bSSFP imaging using spiral trajectories combined with a compressed sensing reconstruction showed good agreement for quantification of biventricular metrics in children with heart disease, despite slightly lower image quality. This technique holds the potential for free breathing data acquisition, with significantly shorter scan times in children.
Collapse
Affiliation(s)
- Jennifer A. Steeden
- UCL Centre for Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, 30 Guildford Street, London, WC1N 1EH UK
| | - Grzegorz T. Kowalik
- UCL Centre for Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, 30 Guildford Street, London, WC1N 1EH UK
| | - Oliver Tann
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, London, WC1N 3JH UK
| | - Marina Hughes
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, London, WC1N 3JH UK
| | - Kristian H. Mortensen
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, London, WC1N 3JH UK
| | - Vivek Muthurangu
- UCL Centre for Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, 30 Guildford Street, London, WC1N 1EH UK
| |
Collapse
|
12
|
Kowalik GT, Steeden JA, Atkinson D, Montalt-Tordera J, Mortensen KH, Muthurangu V. Golden ratio stack of spirals for flexible angiographic imaging: Proof of concept in congenital heart disease. Magn Reson Med 2018; 81:90-101. [PMID: 29802643 DOI: 10.1002/mrm.27353] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 04/19/2018] [Accepted: 04/19/2018] [Indexed: 11/11/2022]
Abstract
PURPOSE In this study, a golden ratio stack of spiral (GRASS) sequence that used both golden step and golden angle ordering was implemented. The aim was to demonstrate that GRASS acquisitions could be flexibly reconstructed as both cardiac-gated and time-resolved angiograms. METHODS Image quality of time-resolved and cardiac-gated reconstructions of the GRASS sequence were compared to 3 conventional stack of spirals (SoS) acquisitions in an in silico model. In 10 patients, the GRASS sequence was compared to conventional breath hold angiography (BH-MRA) in terms of image quality and for vessel measurement. Vessel measurements were also compared to cine images. RESULTS In the cardiac-gated in silico model, the image quality of GRASS was superior to regular and golden-angle with regular step SoS approaches. In the time-resolved model, GRASS image quality was comparable to the golden-angle with regular step technique and superior to regular SoS acquisitions. In patients, there was no difference in qualitative image scores between GRASS and BH-MRA, but SNR was lower. There was good agreement in vessel measurements between the GRASS reconstructions and conventional MR techniques (BH-MRA: 29.8 ± 5.6 mm, time-resolved GRASS-MRA: 29.9 ± 5.4 mm, SSFP diastolic: 29.4 ± 5.8 mm, cardiac-gated GRASS-MRA diastolic: 29.5 ± 5.5 mm, P > 0.87). CONCLUSION We have demonstrated that the GRASS acquisition enables flexible reconstruction of the same raw data as both time-resolved and cardiac-gated volumes. This may enable better interrogation of anatomy in congenital heart disease.
Collapse
Affiliation(s)
- Grzegorz Tomasz Kowalik
- UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London, United Kingdom
| | - Jennifer Anne Steeden
- UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London, United Kingdom
| | - David Atkinson
- University College London, Centre for Medical Imaging, Wolfson House, London, United Kingdom
| | - Javier Montalt-Tordera
- UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London, United Kingdom
| | | | - Vivek Muthurangu
- UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London, United Kingdom.,Great Ormond Street Hospital for Children, Great Ormond Street, London, United Kingdom
| |
Collapse
|
13
|
Manning WJ. Review of Journal of Cardiovascular Magnetic Resonance (JCMR) 2015-2016 and transition of the JCMR office to Boston. J Cardiovasc Magn Reson 2017; 19:108. [PMID: 29284487 PMCID: PMC5747150 DOI: 10.1186/s12968-017-0423-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 12/07/2017] [Indexed: 02/06/2023] Open
Abstract
The Journal of Cardiovascular Magnetic Resonance (JCMR) is the official publication of the Society for Cardiovascular Magnetic Resonance (SCMR). In 2016, the JCMR published 93 manuscripts, including 80 research papers, 6 reviews, 5 technical notes, 1 protocol, and 1 case report. The number of manuscripts published was similar to 2015 though with a 12% increase in manuscript submissions to an all-time high of 369. This reflects a decrease in the overall acceptance rate to <25% (excluding solicited reviews). The quality of submissions to JCMR continues to be high. The 2016 JCMR Impact Factor (which is published in June 2016 by Thomson Reuters) was steady at 5.601 (vs. 5.71 for 2015; as published in June 2016), which is the second highest impact factor ever recorded for JCMR. The 2016 impact factor means that the JCMR papers that were published in 2014 and 2015 were on-average cited 5.71 times in 2016.In accordance with Open-Access publishing of Biomed Central, the JCMR articles are published on-line in the order that they are accepted with no collating of the articles into sections or special thematic issues. For this reason, over the years, the Editors have felt that it is useful to annually summarize the publications into broad areas of interest or themes, so that readers can view areas of interest in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes with previously published JCMR papers to guide continuity of thought in the journal. In addition, I have elected to open this publication with information for the readership regarding the transition of the JCMR editorial office to the Beth Israel Deaconess Medical Center, Boston and the editorial process.Though there is an author publication charge (APC) associated with open-access to cover the publisher's expenses, this format provides a much wider distribution/availability of the author's work and greater manuscript citation. For SCMR members, there is a substantial discount in the APC. I hope that you will continue to send your high quality manuscripts to JCMR for consideration. Importantly, I also ask that you consider referencing recent JCMR publications in your submissions to the JCMR and elsewhere as these contribute to our impact factor. I also thank our dedicated Associate Editors, Guest Editors, and reviewers for their many efforts to ensure that the review process occurs in a timely and responsible manner and that the JCMR continues to be recognized as the leading publication in our field.
Collapse
Affiliation(s)
- Warren J Manning
- From the Journal of Cardiovascular Magnetic Resonance Editorial Office and the Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
14
|
Hauser JA, Taylor AM, Pandya B. How to Image the Adult Patient With Fontan Circulation. Circ Cardiovasc Imaging 2017; 10:CIRCIMAGING.116.004273. [DOI: 10.1161/circimaging.116.004273] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Jakob A. Hauser
- From the Department for Cardiovascular Imaging, University College London, UK (J.A.H., A.M.T., B.P.); Cardiorespiratory Division, Great Ormond Street Hospital, London, UK (J.A.H., A.M.T.); and Barts Heart Centre, St Bartholomew’s Hospital, London, UK (B.P.)
| | - Andrew M. Taylor
- From the Department for Cardiovascular Imaging, University College London, UK (J.A.H., A.M.T., B.P.); Cardiorespiratory Division, Great Ormond Street Hospital, London, UK (J.A.H., A.M.T.); and Barts Heart Centre, St Bartholomew’s Hospital, London, UK (B.P.)
| | - Bejal Pandya
- From the Department for Cardiovascular Imaging, University College London, UK (J.A.H., A.M.T., B.P.); Cardiorespiratory Division, Great Ormond Street Hospital, London, UK (J.A.H., A.M.T.); and Barts Heart Centre, St Bartholomew’s Hospital, London, UK (B.P.)
| |
Collapse
|
15
|
Pennell DJ, Baksi AJ, Prasad SK, Mohiaddin RH, Alpendurada F, Babu-Narayan SV, Schneider JE, Firmin DN. Review of Journal of Cardiovascular Magnetic Resonance 2015. J Cardiovasc Magn Reson 2016; 18:86. [PMID: 27846914 PMCID: PMC5111217 DOI: 10.1186/s12968-016-0305-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Accepted: 11/02/2016] [Indexed: 12/14/2022] Open
Abstract
There were 116 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2015, which is a 14 % increase on the 102 articles published in 2014. The quality of the submissions continues to increase. The 2015 JCMR Impact Factor (which is published in June 2016) rose to 5.75 from 4.72 for 2014 (as published in June 2015), which is the highest impact factor ever recorded for JCMR. The 2015 impact factor means that the JCMR papers that were published in 2013 and 2014 were cited on average 5.75 times in 2015. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is <25 % and has been falling because the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality papers to JCMR for publication.
Collapse
Affiliation(s)
- D. J. Pennell
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - A. J. Baksi
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - S. K. Prasad
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - R. H. Mohiaddin
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - F. Alpendurada
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - S. V. Babu-Narayan
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - J. E. Schneider
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| | - D. N. Firmin
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London, SW 3 6NP UK
| |
Collapse
|
16
|
Wetzl J, Forman C, Wintersperger BJ, D'Errico L, Schmidt M, Mailhe B, Maier A, Stalder AF. High-resolution dynamic CE-MRA of the thorax enabled by iterative TWIST reconstruction. Magn Reson Med 2016; 77:833-840. [PMID: 26888549 DOI: 10.1002/mrm.26146] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 01/07/2016] [Accepted: 01/07/2016] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the clinical benefit of using a new iterative reconstruction technique fully integrated on a standard clinical scanner and reconstruction system using a TWIST acquisition for high-resolution dynamic three-dimensional contrast-enhanced MR angiography (CE-MRA). METHODS Low-dose, high-resolution TWIST datasets of 11 patients were reconstructed using both standard GRAPPA-based reconstruction for reference and iterative reconstruction, which reduces the temporal footprint of reconstructed images. Image quality of both techniques was assessed by two experienced readers, as well as quantitatively evaluated using a time-signal curve analysis. RESULTS Image quality scores consistently and significantly improved by using iterative reconstruction compared with the standard approach. Most notably, the delineation of small to mid-size vasculature improved from a mean Likert score between "nondiagnostic" and "poor" for standard to between "good" and "excellent" for iterative reconstruction. The full width at half maximum of the contrast agent bolus computed from the time-signal curve was also reduced by iterative reconstruction, allowing for more precise bolus timing. CONCLUSION Iterative reconstruction can substantially improve high-resolution dynamic CE-MRA image quality, most notably in small to mid-size vasculature. Dynamic CE-MRA with iterative reconstruction could become an alternative to conventional static 3D CE-MRA, thus simplifying the clinical workflow. Magn Reson Med 77:833-840, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Jens Wetzl
- Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | | | - Bernd J Wintersperger
- Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.,Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Luigia D'Errico
- Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.,Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | | | - Boris Mailhe
- Siemens Medical Solutions USA Inc., Princeton, New Jersey, USA
| | - Andreas Maier
- Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | | |
Collapse
|
17
|
Schicchi N, Secinaro A, Muscogiuri G, Ciliberti P, Leonardi B, Santangelo T, Napolitano C, Agliata G, Basile MC, Guidi F, Tomà P, Giovagnoni A. Multicenter review: role of cardiovascular magnetic resonance in diagnostic evaluation, pre-procedural planning and follow-up for patients with congenital heart disease. Radiol Med 2015; 121:342-51. [DOI: 10.1007/s11547-015-0608-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Accepted: 11/16/2015] [Indexed: 01/21/2023]
|